Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Datos Q A
Q 2 A3
k = 1.5 vc Rh
g B Ac P
n = 0.022
b (m) = 5
Q2 B b 2 ky
Q (m /s) = 42
3 179.816514 A by ky2
g
g (m/s2) = 9.81
A3 1 2 / 3 1/ 2
179.81650 P b 2y 1 k2 v Rh s
B n
yc (m) = 1.628
2
Ac (m2) = 12.113 vn vc2
sc c2 / 3 Emin yc
B (m) = 9.883 Rh 2g
vc (m/s) = 3.467
Pc (m) = 10.869
Rh (m) = 1.114
Q2
sc = 0.005036 yc 3 yc (m) = 1.9303 yc trap (m) = 1.64588
gb 2
Emin (m) = 2.241 1.64588
yc
k 0.49
b
yc (m) = 1.63333333
0.49
0.44068337
= 0.022, con ancho de plantilla de 5 m, el cual conduce un
rgía específica mínima.
2 yr
yc
kyr
1 1 1.4
b
b ky
yc 1 1.4 r 1
0.7 k b
o Martínez Martínez
Un canal circular revestido de cemento pulido conduce un gasto de 8.4 m 3/s con un diámetro de 2.5 m. Determin
flujo sea en régimen crítico.
Q 2 A3 y
cos 1 1 2 B Dsen
n = 0.011 g B D
Q (m3/s) = 8.4 P D
D2
g (m/s ) = 9.81
2 A sen cos
4
D (m) = 2.5
Q A 1 2 / 3 1/ 2
vc Rh v Rh s
yc (m) = 1.316 Ac P n
b (rad.) = 1.623 b° = 93.01
2
Ac (m ) = 2.619
2
vn
Q2 sc c2 / 3
B (m) = 2.497 7.1927 Rh Ecuación propuesta por Swamee (1993)
vc (m/s) = 3.208 g
0.085
A3 yc Q2
3
Pc (m) = 4.059 7.1925 v2
B Emin yc c 1 0.77 5
Rh (m) = 0.645 D gD
2g
sc = 0.00223318
Emin (m) = 1.8401933 yc (m) = 1.314
Metodos para calcular el tirante critico
0.525
yc (m) = 1.313
0.27139057
Q
Z
g
Q
Z
g
iámetro de 2.5 m. Determinar las condiciones para que el
Datos
B
Q (m3/s) = 0.25 Q 2 A3
a (rad.) = 1.0471975512 g B A by ky2
a° = 60 1 yc
60°
k
B b 2 ky
g (m/s2) = 9.81 B 2ky
k = 0.577
A ky2
yc (m) = 0.53
A (m2) = 0.161
Q2
B (m) = 0.609 2Q 2
1/ 5 0.00637
yc 2 g
yc (m) = 0.52 gk A3
B 0.00680
caudal que circula es de 250 litros por segundo.