CALCULO DE POTENCIA DE BOMBA

INGRESE DATOS
TIPO TUBO PVC
Hi= 9 mts
Ha= 1 mts
VOL. T.E. 1000 litros
TIEMPO 30 minutos
L. INPUL. 14 mts
L. SUCC.. 1 mts
Hi n=
CALCULO VOLUMEN T.E.
DOTACION L/dia
PERSONAS u
VOL. T.E. 0 litros
VOL. T.E. 0 m3

Hf Q=𝑉/�
1.- CALCULO CAUDAL
Q= 0.555556 l/s
0.000556 m3/s
Ha GASTOS Y DIAMETRO DE TUBERIA
Q = l/s diametro
0.50 3/4"
1.00 1"
1.60 1 1/4"
3.00 1 1/2"
5.00 2"
2.- DIAMETRO DE LAS TUBERIAS m 8.00 2 1/2"
D. IMPULSION 1" 0.75 0.01905 15.00 3"
D. SUCCION 1 1/4" 0.75 0.01905 25.00 4"

3.- CALCULO PERDIDAS 𝐿�=𝐾/0.022∗𝐷(𝑚𝑒𝑡𝑟𝑜)


Hf= K*L*𝑸^𝟐∗ 〖��〗 ^(−𝟐)
IMPULSION k= 2
Hf=√(�.𝟓𝟒&𝑸/
(�.��𝟕𝟖∗𝑪∗𝑫^(𝟐. D "= 1 L.E.= 2.30909
K= 𝟔𝟑) )) 0.0254
hf=
PERDIDA TUBERIA PERDIDA ACCESORIOS 1"
C= 150 Hftub.= 3.10501 ACCE. L.E. TABLA CANT. TOTAL
hf= 0.22179 CODOS 90° 1.08 5 5.4
TE 1.554 4 6.216
CHECK 1.804 1 1.804
LLAVE 4.318 1 4.318
T. PERDIDA IMPULSION 7.03906 m UNION U. 0
TOTAL PERDIDA ACCESORIOS 3.93405
Hf= K*L*𝑸^𝟐∗ 〖��〗 ^(−𝟐)
SUCCION Hf=√(�.𝟓𝟒&𝑸/
(�.��𝟕𝟖∗𝑪∗𝑫^(𝟐.
K= 𝟔𝟑) ))
hf=
PERDIDA TUBERIA PERDIDA ACCESORIOS 1 1/4"
C= 150 Hftub.= 0.22179 ACCE. L.E. TABLA CANT. TOTAL
hf= 0.22179 hf= 0.22288 CODOS 90° 1.083 1 1.083
UNION U. 0 1 0
V. PIE 7.3 1 7.3
0
T. PERDIDA IMPULSION 2.08102 m 0
TOTAL PERDIDA ACCESORIOS 1.85924

4.- CALCULO Hm
Ps= 2 m
Hm= 21.1201 m

5.- CALCULO DE LA POTENCIA DE LA BOMBA �=(𝑸∗𝑯𝒎)/(𝟕𝟓∗𝒏)

P= 0.21 Hp eficiencia de la boma


n= 0.75

También podría gustarte