𝑄 = 𝑉/𝑡
𝐻 = (ℎ1 − ℎ0 ) + ∆𝑍
Pot eléctrica = V ∗ A
𝑃𝑜𝑡 𝑚𝑒𝑐á𝑛 = 𝜔𝜏
𝑃𝑜𝑡 𝑚𝑒𝑐
𝐸𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝑚𝑒𝑐á𝑛𝑖𝑐𝑎 = ∗ 100
𝑃𝑜𝑡 𝑒𝑙é𝑐𝑡
𝑃𝑜𝑡 𝐻𝑖𝑑
𝐸𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝐻𝑖𝑑𝑟á𝑢𝑙𝑖𝑐𝑎 = ∗ 100
𝑃𝑜𝑡 𝑚𝑒𝑐
𝑃𝑜𝑡 𝐻𝑖𝑑
𝐸𝑓𝑖𝑐𝑖𝑒𝑛𝑐𝑖𝑎 𝑇𝑜𝑡𝑎𝑙 = ∗ 100
𝑃𝑜𝑡 𝑒𝑙𝑒𝑐
Cálculos
10 𝑙𝑡 0.001 𝑚3 𝑚3
𝑄1 = × = 1.07𝑥10−3
9.37 𝑠𝑒𝑔 1 𝑙𝑡 𝑠
10 𝑙𝑡 0.001 𝑚3 −3
𝑚3
𝑄2 = × = 1.00𝑥10
10 𝑠𝑒𝑔 1 𝑙𝑡 𝑠
10 𝑙𝑡 0.001 𝑚3 𝑚3
𝑄3 = × = 9.63𝑥10−4
10.38 𝑠𝑒𝑔 1 𝑙𝑡 𝑠
Pot eléct
N V (volt) A (Ampers)
(Watts)
1 187 1.43 267.41
2 187 1.43 267.41
3 187 1.42 265.54
4 187 1.405 262.735
5 187 1.38 258.06
6 187 1.365 255.255
7 187 1.33 248.71
8 187 1.28 239.36
Válvula cerrada 187 1.24 231.88