Está en la página 1de 14
FLOAT BATTERY CHARGERS eed) ee Creed Qualification EC ec ele Microprocessor Control celia aera (ie Constant potential yee Set a + Floating & charging stationary batteries Bianca coger POWER FROM INNOVATION A combination of advanced technology microprocessor control and performance engineered modular construction make AT30 Series battery chargers easy to set up, easy to operate, and easy to maintain. Miroprocessor ets control itll alfuncions and setngs ‘rough Fon parel switches Press to choose dtl dsploy of Vots/ampsEavalee hous remaining, methods omtnuove med, ‘orautomatcaly timed ‘fer ec interupe ‘rtimer hore when in EoIT mode Presto ter LED lamps nhenin roma mode. APPLICATIONS Power Generation + Substations + Microwave Relay Sites, + Switchgear + Emergency DC Power + DC Operated Breakers + Alarm Systems Uninterruptible Power Systems «DC Control Systems + Signal Systems (ital auton be best tmpegteeton DESIGN FEATURES Modular Construction + Rectifier, microprocessor control, input/output, power transformer, filter and alarm assemblies are all modular and easily replaceable, ‘Thirty-Year Life + AIL AT3O chargers are engineered for greater than 30-year life with a MTBF of 100,000 hours. Trouble Diag Less Than 60 Minutes “Trouble Diagnosis and Repair in ‘an MTTR of less than 60 minutes. + All service can be performed from front of opened unit without disturbing chassis or installed con- duit. Flexible Installation + AILAT3O chargers can be floor ‘mounted, + AT3O chargers in Style-S018 enclosure can be wall or rack mounted Pita! metershows votoge amperage ans Nour. Aso dsplys Selkdagrosti error codes, LED lamps inet abnormal ‘onto ‘summary rey contacto optional ‘naa eto antes provide ‘emeteindcaion Press to snitch to IT ‘mode and ENTE voltage {stings ond ier hour Fast, Online Adjustment + Control, alarm and operating level setpointsare adjusted digitally from the front panel while on line, without the need 0 vary loads or extemal conditions. Engineered for Safety and Acceptance + The AT3O battery charger is designed and tested for worldwide applications. “Meets NEMA PE 5-1996 specification for utility type battery charger + NEMA-1/IP20 type standard enclosure + Meets FCC requirements for part 1S subclass J class A + Agency Approvals for models in Siyle-5018 & Style-5030 enclosures only: + CSAC22.2 Certified + Complies with UL 1072 battery charger and UL 1564 power supply specifications via CSA-NRTLIC listing + CENIEC Compliant + Seismic Zone 4 qualified enclosures STANDARD FEATURES OPTIONS AND TECHNICAL +19 Digital LED meter for Vde, Ade, ACCESSORIES SPECIFICATIONS timer hours and alarm settings + DC output filter per NEMA PES-1996, AC Input «AC On dein git reenter Sate ac. 100 mVrms w/battery (130 Vdc) 208, 240, 480 or 550 Vac 60Hz cha et eta za soheraia saber + Float/equalize selector switch with + Medium or high AIC circuit breakers * Input Voltage Tolerance indicating light {see table below) + 10%, - 129% Viera ainete et aye cen sieges regions seica ie ae light i i form C contacts for: allalarms, £5% Meer ee eT tne amare comeresen eran, “POMESRC ay = Self-diagnostics accepting #22-14 AWG wire) Efficiency iiodieemeniecee tur | Pema gemrtomcen See ae redundancy to protect gains compresion lus) Geer racers route sense eure AC Input lightning arrestor + High de voltage shutdown (HVSD) she = 7 DC Output < Revarda paar pistectoi + Fungus proofing (tropicalization) “Voltage Ratings i 12,24,48,0F 130 Vdc nomi + Front panel controls can be disabled “Static proofing 24,48, oF 130 Vde nominal for secur . Pad + Current Ratings eV autge superesessiopurand Enclose dip sie [25-1000 Ade (se ratings table on output " + Extemal Temperature compensation previous pages) *CU-AL VO compression lugs (tempco) via remote probe ‘Voltage Regulation + Switchboard insulation system + Relay rack mounting (Style-5018 only) frequency variations number-coded wiring + Wall mounting (Style-5018 only) + Membrane front panel “ ANSI61 gray epoxy powder coat + Electrical Noise/Ripple + Padlock w/hasp for front panel door '32 dBc weighted maximum on filtered units finish anne ee ey + Surge Withstand Capability + Alam assembly wit local LEDs and * NEMA 4/12 type enclosure wan Meets \EEE-472/ANSIC37003 summary relay contactor ac allure, «Communications module for DNP3 ac fale righ Véclow Vdcpostive “Level zor MODBUS protocols Environmental ee eee + Forced load sharing module + Operating Ambient Temperature peda Sag St fo fortwo units of tdentalteting on) PSEFtaaeF OTTO SOC) de voltage, independent of + Analog ac ammeter pulcots derating, microprocessor + Operating altitude + Custom parts data package and nee ee 3300 feet (1000 meters) above production test data reports shipped _* Zero-center ground detection meter, sea level without derating twth each unit 5 + Relative Humidity End of discharge alarm + Usersriendly operating manual with 5% to 95% andard dramings = Battery discharge alarm {without condensation) + Quick setup sheet + Custom drawing package w/optional _* Audible Noise eee EADand POF Mes Tess than 65 dBA at any point Sft + ABS certcaton upon ques {Sm rom any vertical surace INPUT / OUTPUT PROTECTION AMPERE INTERRUPTING CAPACITY cau ACEREAER OCHRE TONAL A OP TOWALOC — ‘BREAKER RATINGS® RATINGS. FUSE RATING FUSE RATING oat TYPE (208/240/480 Vac) (125/250Vde) (208-600 Vac) (12/24/48/130¥60) i STNOA 50008 S008 aw TEDIUK AC soma Tng004C 2oo mone 2nqoonc # AGHA 0a 2500 NC “Contact your sales representative for 500-600 Vac circuit breaker AI ratings.

También podría gustarte