Está en la página 1de 18

CALCULO DE HARDY CROSS

DATOS:
log c/d tramo : 1000 m
diam int. Tub. : 400 mm
fluido: agua
viscosidad cinematica: 1e-6m2/s

Q caudal
D diametro
A area tub
v velocidad
Re | reynols
f coeficiente de friccion
L longitud
K coeficiente de perdida de cargas lineales

Línea Q D A v Re f
MALLA I 1 -0.3 0.3 #N/A #N/A #N/A #N/A
2 0.4 0.3 #N/A #N/A #N/A #N/A
4 -0.1 0.3 #N/A #N/A #N/A #N/A
MALLA II 1 0.3 0.3 #N/A #N/A #N/A #N/A
3 -0.3 0.3 #N/A #N/A #N/A #N/A
5 0.1 0.3 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.3 #N/A #N/A #N/A #N/A


2 #N/A 0.3 #N/A #N/A #N/A #N/A
4 #N/A 0.3 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.3 #N/A #N/A #N/A #N/A
3 #N/A 0.3 #N/A #N/A #N/A #N/A
5 #N/A 0.3 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.3 #N/A #N/A #N/A #N/A


2 #N/A 0.3 #N/A #N/A #N/A #N/A
4 #N/A 0.3 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.3 #N/A #N/A #N/A #N/A
3 #N/A 0.3 #N/A #N/A #N/A #N/A
5 #N/A 0.3 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.3 #N/A #N/A #N/A #N/A


2 #N/A 0.3 #N/A #N/A #N/A #N/A
4 #N/A 0.3 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.3 #N/A #N/A #N/A #N/A
3 #N/A 0.3 #N/A #N/A #N/A #N/A
5 #N/A 0.3 #N/A #N/A #N/A #N/A
MALLA I 1 #N/A 0.3 #N/A #N/A #N/A #N/A
2 #N/A 0.3 #N/A #N/A #N/A #N/A
4 #N/A 0.3 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.3 #N/A #N/A #N/A #N/A
3 #N/A 0.3 #N/A #N/A #N/A #N/A
5 #N/A 0.3 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.3 #N/A #N/A #N/A #N/A


2 #N/A 0.3 #N/A #N/A #N/A #N/A
4 #N/A 0.3 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.3 #N/A #N/A #N/A #N/A
3 #N/A 0.3 #N/A #N/A #N/A #N/A
5 #N/A 0.3 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.3 #N/A #N/A #N/A #N/A


2 #N/A 0.3 #N/A #N/A #N/A #N/A
4 #N/A 0.3 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.3 #N/A #N/A #N/A #N/A
3 #N/A 0.3 #N/A #N/A #N/A #N/A
5 #N/A 0.3 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.4 #N/A #N/A #N/A #N/A


2 #N/A 0.4 #N/A #N/A #N/A #N/A
4 #N/A 0.4 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.4 #N/A #N/A #N/A #N/A
3 #N/A 0.4 #N/A #N/A #N/A #N/A
5 #N/A 0.4 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.4 #N/A #N/A #N/A #N/A


2 #N/A 0.4 #N/A #N/A #N/A #N/A
4 #N/A 0.4 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.4 #N/A #N/A #N/A #N/A
3 #N/A 0.4 #N/A #N/A #N/A #N/A
5 #N/A 0.4 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.4 #N/A #N/A #N/A #N/A


2 #N/A 0.4 #N/A #N/A #N/A #N/A
4 #N/A 0.4 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.4 #N/A #N/A #N/A #N/A
3 #N/A 0.4 #N/A #N/A #N/A #N/A
5 #N/A 0.4 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.4 #N/A #N/A #N/A #N/A


2 #N/A 0.4 #N/A #N/A #N/A #N/A
4 #N/A 0.4 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.4 #N/A #N/A #N/A #N/A
3 #N/A 0.4 #N/A #N/A #N/A #N/A
5 #N/A 0.4 #N/A #N/A #N/A #N/A
MALLA I 1 #N/A 0.4 #N/A #N/A #N/A #N/A
2 #N/A 0.4 #N/A #N/A #N/A #N/A
4 #N/A 0.4 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.4 #N/A #N/A #N/A #N/A
3 #N/A 0.4 #N/A #N/A #N/A #N/A
5 #N/A 0.4 #N/A #N/A #N/A #N/A

MALLA I 1 #N/A 0.4 #N/A #N/A #N/A #N/A


2 #N/A 0.4 #N/A #N/A #N/A #N/A
4 #N/A 0.4 #N/A #N/A #N/A #N/A
MALLA II 1 #N/A 0.4 #N/A #N/A #N/A #N/A
3 #N/A 0.4 #N/A #N/A #N/A #N/A
5 #N/A 0.4 #N/A #N/A #N/A #N/A
CULO DE HARDY CROSS

L K C Corrección
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A

1000 #N/A #N/A #N/A


1000 #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A #N/A
1000 #N/A #N/A
1000 #N/A #N/A
DETERMINAR LA DISTRIBUCION DE LOS CAUDALES ENLA SIGUIENTE TUBERIA. SI A ES EL PUNTO

530 lts/seg 100 lit/seg


A 400-40 300-40 C
300 B 120
230 80 40
600 - 40
600-30 600-30

E 480 - 40 F
120 lits/seg 500 - 30 120 lits/seg 110 lits/seg
110 70

Q inicial = 100 80 110 120 120 530 lits/seg

CIRCURITO TRAMO DIAM (m) L(m) Q supuesto hl hl/Q Δ


AB 0.4 400 0.3 7.868043 0.026227 4.6596
BE 0.3 600 0.08 4.145368 0.051817 4.6596
I AD 0.4 600 0.23 -7.215788 0.031373 4.6596
DE 0.3 500 0.11 -6.228975 0.056627 4.6596
-1.431352 0.166044

CIRCURITO TRAMO DIAM (m) L(m) Q supuesto hl hl/Q Δ


BC 0.4 300 0.12 1.082427 0.00902 13.9800
CF 0.3 600 0.04 1.149097 0.028727 13.9800
II BE 0.3 600 0.08 -4.145368 0.051817 13.9800
EF 0.4 480 0.07 -0.638464 0.009121 13.9800
-2.552309 0.098686
ERIA. SI A ES EL PUNTO DE INGRESO Y F ES EL PUNTO DE DESCARGA

C= 100

80 lis/seg
QxL^(0.54)=
0.2788xCxD^(2.63)

Q corregido
304.6596
84.6596
234.6596
114.6596

Q corregido
133.9800
53.9800
93.9800
83.9800
1
1.856 0.538793
1.856

7.624891
2.50444
3.04455
7.896213

3
9 3
CALCULAR EL CAUDAL POR EL METODO DE HARDY CROSS

TRAMO LARGO DIAMETRO


m mm
1-2 1020 200
2-3 1250 150
3-4 950 150
4-1 1430 250
2-4 1050 100

CIRCURITO TRAMO DIAM (m) L(m) Q supuesto hl hl/Q


1-2 0.2 1020 0.05 21.2478551 0.4249571
I 2-4 0.1 1050 0.01 32.4756691 3.24756691
1-4 0.25 1430 0.015 -1.08234163 0.07215611
52.6411826 3.74468012

CIRCURITO TRAMO DIAM (m) L(m) Q supuesto hl hl/Q


2-3 0.15 1250 0.01 5.37042739 0.53704274
II 2-4 0.1 1050 0.01 -32.4756691 3.24756691
4-3 0.15 950 0.025 -22.2568769 0.89027507
-49.3621186 4.67488472

CIRCURITO TRAMO DIAM (m) L(m) Q supuesto hl hl/Q


1-2 0.2 1020 42.4013 15.6603154 0.36933572
I 2-4 0.1 1050 -3.3063 -4.18651405 1.266236
1-4 0.25 1430 -22.5987 -2.3111485 0.1022691
9.16265284 1.73784082

CIRCURITO TRAMO DIAM (m) L(m) Q supuesto hl hl/Q


2-3 0.15 1250 15.7076 12.388 0.7887
II 2-4 0.1 1050 -3.3063 4.187 1.2662
4-3 0.15 950 -19.2924 -13.776 0.7141
2.798 2.7689814
CROSS

C= 100

Δ Q corregido
-7.5987 42.4013
-13.3063 -3.3063
7.5987 -22.5987

Δ Q corregido
5.7076 15.7076
13.3063 -3.3063
5.7076 -19.2924

Δ Q corregido
-2.8500 39.5513
-2.8500 -6.1562
-2.8500 -25.4487

Δ Q corregido
-0.5463 15.1613
8.6164 5.3101
-0.5463 -19.8387
DATOS: Q = 0.56
b = 0.8
y = 0.5
s = 0.005
B = 0.8
n = 0.018

Area A=b*y A= 0.4


Perimetro P=b+2y P= 1.8
Radio hidraulico RH=A/P Rh= 0.222
Espejo de agua B=b B= 0.8

formula de manig
Q= 0.576

V= 1.441

podemos determinar el tirante del canal mediante un tanteo

Ecuacion en valor constante


funcion de y
Y b 0.142552727
0.1 0.8 0.0148530843
0.2 0.8 0.0417585882
0.3 0.8 0.0740627862
0.4 0.8 0.1094384606
0.5 0.8 0.1467523222
0.6 0.8 0.1853739618
0.7 0.8 0.2249218211
0.8 0.8 0.2651505072
0.9 0.8 0.3058946834
1 0.8 0.3470387396
1.1 0.8 0.3884993386
1.2 0.8 0.4302148557
1.3 0.8 0.4721387227
1.4 0.8 0.5142350847
CANAL TRA
DATOS: Q
b
y
s
B
n
Z
CANAL TRAPEZOIDAL
= 1.12785972
= 0.8
= 0.5
= 0.005
= 0.8
= 0.018
= 1

Area A=(b+zy)y A= 0.65


Perimetro P=b+ P= 2.214213562
Radio hidraulico RH=A/P Rh= 0.293557953
Espejo de agua B=b+2zy B= 1.8

Q= 1.127859721

V= 0.061347481

podemos determinar el tirante del canal mediante un tanteo

Y b
0.1 0.8
0.2 0.8
0.3 0.8
0.4 0.8
0.5 0.8
0.6 0.8
0.7 0.8
0.8 0.8
0.9 0.8
1 0.8
1.1 0.8
1.2 0.8
l canal mediante un tanteo

Ecuacion en valor constante


funcion de y

0.01714065 0.28710621
0.05556691
0.11292558
0.18973973
0.28710621
0.40629978
0.54865097
0.7155001
0.90817817
1.12799863
1.3762541
1.65421523
LINEA DE IMPULSION

DATOS:
Q litros= 20 l/seg
0.02 m3/seg
N= 7 horas de bombeo
c= 150 pvc rugosidad
L= 340 m

1) hallar caudal de diseño


Qd= Q/(n/24)
Qd= 0.068571429 m3/seg

2) halla diametro (brees)


D=1.3 ((N/24)^(1/4))*((Qd^(1/2)))
D= 0.250170819 m
D= 9.849244848 pug
10 buscamos un diametro comercial redondenado
0.254 m
3) hallar la velocidad
V= Qd/A
V= 1.3533

4) calculo de perdida de carga

Q=0.2785xCxD^(2.63)x(J/L)^(2.63)
J= 1.875192984