Está en la página 1de 7

TRANSITO EN CAUCES - CALCULO DE FACTORES K

t I O I-O S(I-O) Vt
horas m /s
3
m /s
3
m /s
3
m3/s
0 65.49 46.62 18.87 18.87 18.87
1 103.23 77.7 25.53 44.4 44.4
2 143.19 84.36 58.83 103.23 103.23
3 227.55 157.62 69.93 173.16 173.16
4 233.1 203.13 29.97 203.13 203.13
5 259.74 205.35 54.39 257.52 257.52
6 360.75 236.43 124.32 381.84 381.84
7 614.94 325.23 289.71 671.55 671.55
8 695.97 440.67 255.3 926.85 926.85
9 583.86 540.57 43.29 970.14 970.14
10 479.52 591.63 -112.11 858.03 858.03
11 279.72 533.91 -254.19 603.84 603.84
12 225.33 411.81 -186.48 417.36 417.36
13 175.38 279.72 -104.34 313.02 313.02
14 144.3 217.56 -73.26 239.76 239.76
15 116.55 178.71 -62.16 177.6 177.6
16 99.9 158.73 -58.83 118.77 118.77
17 88.8 124.32 -35.52 83.25 83.25
18 75.48 105.45 -29.97 53.28 53.28
19 65.49 92.13 -26.64 26.64 26.64
20 65.49 83.25 -17.76 8.88 8.88

X=0.05 X=0.
1200 1200

1000 1000

800 f(x) = 1.7543269638x - 108.9418747242 800 f(x) = 1.7805785339x - 115.3


R² = 0.8932843215 R² = 0.9138751482
600 600
VT
VT

400 400

200 200

0 0

-200 -200
0 100 200 300 400 500 600 700 0 100 200 300

XI+(1-X)O (m3/seg) XI+

X=0.20 X=0.
1200 1200

1000 1000

800 f(x) = 1.8183426598x - 124.5896854382 800 f(x) = 1.8294512515x - 127


R² = 0.9480114823 R² = 0.9612251476
X=0.20 X=0.
1200 1200

1000 1000

800 f(x) = 1.8183426598x - 124.5896854382 800 f(x) = 1.8294512515x - 127


R² = 0.9480114823 R² = 0.9612251476
600 600

VT
400
VT

400
200 200

0 0

-200 -200
0 100 200 300 400 500 600 0 100 200

XI+(1-X)O (m3/seg) XI+

X=0.35 X=0.
1200 1200

1000 1000

800 f(x) = 1.8357755203x - 128.937061368 800 f(x) = 1.8311235406x - 127


R² = 0.9794435179 R² = 0.9843904139
600 600

VT
VT

400 400

200 200

0 0

-200 -200
0 100 200 300 400 500 600 0 100 200

XI+(1-X)O (m3/seg) XI+

X=0.50
1200
1000

800 f(x) = 1.8071465691x - 122.1016564713


R² = 0.9861638721
600
VT

400
200

0
-200
0 100 200 300 400 500 600

XI+(1-X)O (m3/seg)
S - CALCULO DE FACTORES K Y X.

XI+(1-X)O
X
0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5
48 49 49 50 51 52 53 54 55 56
79 80 82 83 84 85 87 88 89 90
87 90 93 96 99 102 105 108 111 114
161 165 168 172 175 179 182 186 189 193
205 206 208 209 211 212 214 215 217 218
208 211 214 216 219 222 224 227 230 233
243 249 255 261 268 274 280 286 292 299
340 354 369 383 398 412 427 441 456 470
453 466 479 492 504 517 530 543 556 568
543 545 547 549 551 554 556 558 560 562
586 580 575 569 564 558 552 547 541 536
521 508 496 483 470 458 445 432 420 407
402 393 384 375 365 356 347 337 328 319
275 269 264 259 254 248 243 238 233 228
214 210 207 203 199 196 192 188 185 181
176 172 169 166 163 160 157 154 151 148
156 153 150 147 144 141 138 135 132 129
123 121 119 117 115 114 112 110 108 107
104 102 101 99 98 96 95 93 92 90
91 89 88 87 85 84 83 81 80 79
82 81 81 80 79 78 77 76 75 74

X=0.1 X=0.15
1200

1000
f(x) = 1.7805785339x - 115.3490821968 800 f(x) = 1.801998589x - 120.5848987214
R² = 0.9138751482 R² = 0.9321796221
600
VT

400

200

0
-200
100 200 300 400 500 600 700 0 100 200 300 400 500
XI+(1-X)O (m3/seg) XI+(1-X)O (m3/seg)

X=0.25 X=0.30
1200

1000
f(x) = 1.8294512515x - 127.3244077621 800 f(x) = 1.8352549226x - 128.7718773532
R² = 0.9612251476 R² = 0.9717201295
X=0.25 X=0.30
1200
1000
f(x) = 1.8294512515x - 127.3244077621 800 f(x) = 1.8352549226x - 128.7718773532
R² = 0.9612251476 R² = 0.9717201295
600

VT
400
200

0
-200
100 200 300 400 500 600 0 100 200 300 400

XI+(1-X)O (m3/seg) XI+(1-X)O (m3/seg)

X=0.40 X=0.45
1200

1000
f(x) = 1.8311235406x - 127.8464513227 800 f(x) = 1.8214918879x - 125.5465572056
R² = 0.9843904139 R² = 0.9866023476
600
VT

400

200

0
-200
100 200 300 400 500 600 0 100 200 300 400

XI+(1-X)O (m3/seg) XI+(1-X)O (m3/seg)


=0.15

20.5848987214

300 400 500 600 700

XI+(1-X)O (m3/seg)

=0.30

- 128.7718773532
=0.30

- 128.7718773532

300 400 500 600

XI+(1-X)O (m3/seg)

=0.45

- 125.5465572056

300 400 500 600

XI+(1-X)O (m3/seg)
t 1 K 1.82 X 0.45

C1= -0.212525
C2= 0.8787475
C3= 0.33377748
C1+C2+C3= 1

t I C1 IJ+1 C2 IJ C 3 OJ OJ+1
0 44 - - - 44
1 89 -18.914724 38.6648901 14.6862092 34.4363757
2 144 -30.603598 78.2085276 11.4940868 59.0990168
3 266 -56.531646 126.53964 19.725921 89.7339157
4 699 -148.55496 233.746835 29.9511604 115.143032
5 988 -209.97468 614.244504 38.4321514 442.701972
6 1166 -247.80413 868.202532 147.763949 768.16235
7 1177 -250.14191 1024.61959 256.395295 1030.87298
8 1221 -259.493 1034.28581 344.082186 1118.87499
9 1277 -271.3944 1072.9507 373.455277 1175.01157
10 1365 -290.0966 1122.16056 392.192404 1224.25636
11 1343 -285.42105 1199.49034 408.629205 1322.69849
12 1687 -358.52965 1180.15789 441.486972 1263.11522
13 1343 -285.42105 1482.44704 421.599417 1618.6254
14 1310 -278.40773 1180.15789 540.26071 1442.01088
15 1116 -237.17788 1151.15923 481.310759 1395.2921

También podría gustarte

  • Entrega Final Acuasan
    Entrega Final Acuasan
    Documento36 páginas
    Entrega Final Acuasan
    Fernando Pérez López
    Aún no hay calificaciones
  • Entrega Final Acuasan
    Entrega Final Acuasan
    Documento36 páginas
    Entrega Final Acuasan
    Fernando Pérez López
    Aún no hay calificaciones
  • Entrega Final Acuasan
    Entrega Final Acuasan
    Documento35 páginas
    Entrega Final Acuasan
    Fernando Pérez López
    Aún no hay calificaciones
  • Secop Ii
    Secop Ii
    Documento16 páginas
    Secop Ii
    Fernando Pérez López
    Aún no hay calificaciones
  • Entrega Final Acuasan
    Entrega Final Acuasan
    Documento36 páginas
    Entrega Final Acuasan
    Fernando Pérez López
    Aún no hay calificaciones
  • Diseño de Una Ptap
    Diseño de Una Ptap
    Documento40 páginas
    Diseño de Una Ptap
    Fernando Pérez López
    Aún no hay calificaciones
  • Nutricion y Emociones
    Nutricion y Emociones
    Documento84 páginas
    Nutricion y Emociones
    Fernando Pérez López
    100% (1)
  • Entrega Final Acuasan
    Entrega Final Acuasan
    Documento36 páginas
    Entrega Final Acuasan
    Fernando Pérez López
    Aún no hay calificaciones
  • Taller 2
    Taller 2
    Documento5 páginas
    Taller 2
    Fernando Pérez López
    Aún no hay calificaciones
  • Calidad de Agua para Diseñar Una Ptap
    Calidad de Agua para Diseñar Una Ptap
    Documento11 páginas
    Calidad de Agua para Diseñar Una Ptap
    Fernando Pérez López
    Aún no hay calificaciones
  • Taller 2
    Taller 2
    Documento5 páginas
    Taller 2
    Fernando Pérez López
    Aún no hay calificaciones
  • Trabajo Hidro
    Trabajo Hidro
    Documento18 páginas
    Trabajo Hidro
    Fernando Pérez López
    Aún no hay calificaciones
  • Taller 2
    Taller 2
    Documento5 páginas
    Taller 2
    Fernando Pérez López
    Aún no hay calificaciones
  • Taller de Curvas IDT
    Taller de Curvas IDT
    Documento15 páginas
    Taller de Curvas IDT
    Fernando Pérez López
    Aún no hay calificaciones
  • Taller 1
    Taller 1
    Documento3 páginas
    Taller 1
    Fernando Pérez López
    Aún no hay calificaciones
  • Foro Tema 6
    Foro Tema 6
    Documento7 páginas
    Foro Tema 6
    Fernando Pérez López
    Aún no hay calificaciones