Está en la página 1de 4

" DISEO DE DESARENADOR "

"MEJORAMIENTO DEL CANAL DE RIEGO LOMA LARGA SALLIQUE, DISTRITO DE SALLIQUE, PROVINCIA D
JAN - REGIN CAJAMARCA"

Lt Ld L
Compuerta de lavado
A
Compuerta de admision
B

Bd R
A

Canal de salida

Canal de entrada B Vertedero

So
S1

A A B B
DATOS:
Canal: Bc = 0.40 m
S = 0.001
n = 0.014
Q = 0.28 m3/s
particula = 0.60 mm

SOLUCION:
Por tablas:
particula = 0.60 mm w = 0.0648 m/s

Asumiendo V = 0.40 m/s

Area de la seccion: A = Q/V


A = 0.70 m2
Hd A
Recomendable:
Bd/Hd = 2.5
Bd
A = Bd X Hd = 0.70 m2
Hd = 0.53 m tomamos: Hd = 0.60 m
Bd = 1.32 m Bd = 1.40 m

Longitud de transicion:
Lt = (Bd - Bc)/(2tg12.5)
Lt = 2.26 m tomamos: Lt = 2.30 m

Longitud activa del desarenador:


K = 1.2
Hd = 0.60 m
V = 0.40 m/s
w = 0.0648 m/s

Ld = K.Hd.V/W
Ld = 4.44 m tomamos: Ld = 4.50 m

Longitud de vertedero:
Q = c.Lv.(h^(3/2))
c=2
h = 0.25 m mxima carga sobre el vertedero

Lv = Q/(c.(h^(3/2)))
Lv = 1.12 m

L = Rsen

R-Bd R

Bd

del grfico:
cos = (R-Bd)/R
cos = 1-Bd/R.. (*)

Lv = .R./180
R = Lv*180/.(**)

(**) en (*)
..Bd = 180.Lv.(1-cos)
= 13.58
iterando: = 45.28

Por consiguiente:
R = Lv*180/
R = 1.42 m

L = Rsen
L = 1.01 m tomamos: L = 1.10 m

Longitud Total:
LT = Lt + Ld + (L+Lv)/2
LT = 7.91 m
SALLIQUE, PROVINCIA DE

B B