CALCULO DE CARGAS DINMICAS SOBRE TORRES DEBIDAS AL VIENTO (C.F.E. 2008) VEL.

REGIONAL 170 KM/HRS


DESCRIPCIN: TORRE ARRIOSTRADA DE 72 M DE ALTURA
SITIO: ESTRUC. SEGN RESP A VIENTO TIPO 2
UBICACIN: ESTRUC. SEGN IMPORT. GRUPO A
VEL. DE DISEO (Km/hr): REGIONAL 170 CAT. DEL TERRENO POR RUGOSIDAD: 1
PERIODO DE RETORNO 200 AOS FACTOR DE TOPOGRAFA: 1
ELEVACIN SNM PROPUESTA (m): GOOGLE EARTH 54 BASE DE LA TORRE(m): 0.90
TEMPERATURA DE LA REGIN PROPUESTA (C) 23.80 ALTURA DE LA TORRE (m): 72
TIPO DE PIERNA (ANGULO=L, REDONDO=O): O ANLISIS A UTILIZAR DINMICO
TIPO DE CELOSA (ANGULO=L, REDONDO=O): L TIPO DE TORRE: CUADRADA, TRIANGULAR TRIANGULAR

NOTA: LA PRIMERA SECCIN DEBER SER LA PARTE SUPERIOR DE LA TORRE


DATOS DE LA SECCIN 1 DATOS DE LA SECCIN 2
LONGITUD(M): 6 (72-66M) LONGITUD(M): 6 (66-60M)
ANCHO SUPERIOR (M): 0.90 ANCHO SUPERIOR (M): 0.90
TIPO DE SECCIN (K,V,X,Z): Z TIPO DE SECCIN (K,V,X,Z): Z
DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40 DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40
DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16" DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16"

DATOS DE LA SECCIN 3 DATOS DE LA SECCIN 4


LONGITUD(M): 6 (60-54M) LONGITUD(M): 6 (54-48M)
ANCHO SUPERIOR (M): 0.90 ANCHO SUPERIOR (M): 0.90
TIPO DE SECCIN (K,V,X,Z): Z TIPO DE SECCIN (K,V,X,Z): Z
DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40 DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40
DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16" DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16"

DATOS DE LA SECCIN 5 DATOS DE LA SECCIN 6


LONGITUD(M): 6 (48-42M) LONGITUD(M): 6 (42-36M)
ANCHO SUPERIOR (M): 0.90 ANCHO SUPERIOR (M): 0.90
TIPO DE SECCIN (K,V,X,Z): Z TIPO DE SECCIN (K,V,X,Z): Z
DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40 DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40
DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16" DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16"

DATOS DE LA SECCIN 7 DATOS DE LA SECCIN 8


LONGITUD(M): 6 (36-30M) LONGITUD(M): 6 (30-24M)
ANCHO SUPERIOR (M): 0.90 ANCHO SUPERIOR (M): 0.90
TIPO DE SECCIN (K,V,X,Z): Z TIPO DE SECCIN (K,V,X,Z): Z
DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40 DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40
DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16" DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16"

DATOS DE LA SECCIN 9 DATOS DE LA SECCIN 10


LONGITUD(M): 6 (24-18M) LONGITUD(M): 6 (18-12M)
ANCHO SUPERIOR (M): 0.90 ANCHO SUPERIOR (M): 0.90
TIPO DE SECCIN (K,V,X,Z): Z TIPO DE SECCIN (K,V,X,Z): Z
DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40 DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40
DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16" DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16"

DATOS DE LA SECCIN 11 DATOS DE LA SECCIN 12


LONGITUD(M): 6 (12-6M) LONGITUD(M): 6 (6-0M)
ANCHO SUPERIOR (M): 0.90 ANCHO SUPERIOR (M): 0.90
TIPO DE SECCIN (K,V,X,Z): Z TIPO DE SECCIN (K,V,X,Z): Z
DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40 DIM. DE PIERNA(IN): ASTM A53 - B 2.5" CED 40
DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16" DIM. DE HOR./DIAG. (IN): ASTM A36 / A572 -50 LI 2"X 3/16"

ACCESORIO PESO
MICROONDA DE 1.20 M (INCLUYE SOPORTE GK/PZA.) 4 FT 157.00
MICROONDA DE 1.80 M (INCLUYE SOPORTE GK/PZA.) 6 FT 207.00
PARARRAYOS Y LUCES DE OBSTRUCCIN (KG) 10.00
LNEAS FEEDER = 7/8" (KG/M) 0.80
CABLE DE SISTEMA DE ILUMINACIN (KG/M) 1.50
CABLE DEL PARARRAYOS (KG/M) 2.00
ESCALERA DE ASCENSO (KG/M) 8.53
CHAROLA DE CABLE (KG/M) 6.20

NOTAS:
PARA EL CALCULO DE EL PESO DE ACCESORIOS, SE CONSIDERA:
1.- PESO POR EL NMERO DE ANTENAS TIPO MICROONDAS EN EL TRAMO
2.- 2 LNEAS FEEDER POR CADA ANTENA TIPO MICROONDAS
3.- EL PESO DEL PARARRAYOS Y LUCES DE OBSTRUCCIN SER CONSIDERADO SOLO EN LA CSPIDE
4.- EL PESO DE LOS CABLES PARARRAYOS E ILUMINACIN SERN CONSIDERADOS A LO LARGO DE LA TORRE.
5.- EL PESO DE LA ESCALERA DE ASCENSO AL IGUAL QUE LA CHAROLA DE CABLE SER CONSIDERADO A LO LARGO DE LA TORRE Y DISTRIBUIDO EN DOS PIERNAS.
6.- NO SE CONSIDERA HIELO (PARA ESTA CONDICIN DE CARGA)
REA DEL NM. DE FEEDERS MULTIPLICADA POR LA ALTURA DEL TRAMO CONSIDERADO
PARA EL CALCULO DEL COEFICIENTE DE ARRASTRE ADICIONAL DEBIDO A ACCESORIOS:
0.80 x # FEEDER x LONGITUD DE TRAMO) / # NODOS = PESO
*1 ERA. SECCIN.
(0.80 KG/M X 4 CABLES x 6 M)/18 DODOS: 1.07 KG

SE SIGUE EJEMPLO III.F EJEMPLO 7 DE LA CFE-VIENTO 2008 (AYUDAS DE DISEO)


CALCULO DE PARMETROS DE DISEO, SEGN CFE-VIENTO-2008:
FACTOR DE EXPOSICIN (F'RZ): = 0.15 Iv(Zs) 0.118 SECCIN mr (KG)
COEFICIENTE b = 1.17 Z0= 0.01 SL(Zs,n1,x) 0.044 1 543.31
EXPONENTE ' = 0.12 Zmin= 1.00 L(Zs) 191.38 M 2 357.56
= 0.44 B2 0.922 3 182.58
COEF. PARA PRESIN DINMICA BASE, qz: n1,x= 1.092 h 3.199 4 123.71
(MM. DE HG) = 755.68 n',x= FRECUENCIA RAYLEIGH= 1Hz=1cps b 0.070 5 79.83
G= 0.998 F'rz 1.04 Rh(h) 0.238 6 48.38
V'D(M/S) 49.15 Rb(b) 0.935 7 26.96
2
COEF. PARA FACTOR DE RUGOSIDAD Y ALTURA, Frz: mr = 1,424.41 R 1.527 8 13.36
= 0.099 PESO mtotal (KG)= 4,645.09 v 0.862 Hz 9 5.54
= 245 kp 3.705 10 1.71
c= 1.137 CRG 0.321 11
est,x= 0.005 hr PARA VIDRIO O PLSTICO (MM)= 0.0015 CG 0.309 12
m = 1.75 DIMETRO DE LNEA FEDEERS (IN) 0.875 7/8" FM 1.00 SUMA = 1,382.92
FAD 1.35
TABLA DE CARGAS DE VIENTO:
TORRE ARRIOSTRADA DE 72 M " 0 "
2 PESO EST. PESO ACCE.
SECCIN Ap (M ) Ac (M2) AT (M2) (As/AT) Ca PIERNAS Cat CELOSA # Cable (Feeder) Cau Feeders Kre Feeders Kin Feeders A Feeders Cat
Staad (KG) (KG)
1 0.876 0.643 5.400 285.0 345.58 0.281 1.211 2.492 4 0.592 1.00 0.65 0.53 0.13
2 0.876 0.643 5.400 285.0 285.58 0.281 1.364 2.492 4 0.592 1.00 0.62 0.53 0.13
3 0.876 0.643 5.400 285.0 128.58 0.281 1.372 2.492 4 0.592 1.00 0.62 0.53 0.13
4 0.876 0.643 5.400 285.0 128.58 0.281 1.381 2.492 4 0.592 1.00 0.61 0.53 0.13
5 0.876 0.643 5.400 285.0 128.58 0.281 1.391 2.492 4 0.592 1.00 0.61 0.53 0.13
6 0.876 0.643 5.400 285.0 128.58 0.281 1.403 2.492 4 0.592 1.00 0.61 0.53 0.13
7 0.876 0.643 5.400 285.0 128.58 0.281 1.417 2.492 4 0.592 1.00 0.61 0.53 0.13
8 0.876 0.643 5.400 285.0 128.58 0.281 1.436 2.492 4 0.592 1.00 0.60 0.53 0.13
9 0.876 0.643 5.400 285.0 128.58 0.281 1.458 2.492 4 0.592 1.00 0.60 0.53 0.12
10 0.876 0.643 5.400 285.0 128.58 0.281 1.458 2.492 4 0.592 1.00 0.60 1.60 0.37

ESCALERA DE ASCENSO " 60 " SE CONSIDERA CHAROLA DE CABLES " 0 "

A ESC Cfx y Cfy COEF. DE Kre Kin Cau CAMA Kre CAMA Kin CAMA
SECCIN es Cat A ch (M) ca Cat Cat Cat + Cat
(M) FUERZ = 0 ESCALERA ESCALERA GUA GUA GUA

1 0.27 1.80 0.70 60 1.13 0.25 0.69 1.80 0.70 0.00 0.65 0.37 0.76 2.51
2 0.27 1.80 0.80 60 1.08 0.28 0.69 1.80 0.80 0.00 0.62 0.40 0.81 2.65
3 0.27 1.80 0.80 60 1.08 0.28 0.69 1.80 0.80 0.00 0.62 0.40 0.81 2.65
4 0.27 1.80 0.80 60 1.07 0.28 0.69 1.80 0.80 0.00 0.61 0.40 0.80 2.66
5 0.27 1.80 0.80 60 1.07 0.27 0.69 1.80 0.80 0.00 0.61 0.40 0.80 2.66
6 0.27 1.80 0.80 60 1.07 0.27 0.69 1.80 0.80 0.00 0.61 0.40 0.80 2.66
7 0.27 1.80 0.80 60 1.06 0.27 0.69 1.80 0.80 0.00 0.61 0.40 0.80 2.67
8 0.27 1.80 0.80 60 1.06 0.27 0.69 1.80 0.80 0.00 0.60 0.39 0.79 2.67
9 0.27 1.80 0.80 60 1.05 0.27 0.69 1.80 0.80 0.00 0.60 0.39 0.79 2.68
10 0.27 1.80 0.80 60 1.05 0.27 0.69 1.80 0.80 0.00 0.60 0.39 1.03 2.93
11
12
b*Vd =58.51
VD (KM/HR) Feq NODAL
2 Feq NODAL Feq NODAL Feq NODAL Feq NODAL Feq nodal No. NOD. Feq nodal x nodo
SECCIN Z (M) Zp (M) Frz Velocidad de qz (KG/M ) CHAROLA Cat
PIERNAS (KG) CELOSA(KG) CABLES (KG) (KG)
Escalera (kg) TOTAL /SECC. (kg)
Diseo (KG)
1 72 69 1.38 234.02 262.37 375.03 566.11 72.03 135.88 198.43 1.75 1,347.48 18 74.86
2 66 63 1.36 231.92 257.69 414.86 556.00 67.62 145.79 212.90 1.84 1,397.16 18 77.62
3 60 57 1.35 229.64 252.63 409.04 545.09 66.14 142.59 208.23 1.85 1,371.08 18 76.17
4 54 51 1.34 227.12 247.13 402.68 533.22 64.52 139.11 203.15 1.85 1,342.69 18 74.59
5 48 45 1.32 224.32 241.08 395.70 520.17 62.75 135.29 197.57 1.86 1,311.48 18 72.86
6 42 39 1.30 221.17 234.34 387.93 505.64 60.78 131.04 191.35 1.86 1,276.74 18 70.93
7 36 33 1.28 217.54 226.72 379.21 489.19 58.54 126.21 184.30 1.87 1,237.44 18 68.75
8 30 27 1.25 213.26 217.89 369.31 470.13 55.93 120.58 176.09 1.88 1,192.05 18 66.22
9 24 21 1.22 208.02 207.31 356.77 447.31 52.85 113.95 166.40 1.90 1,137.28 18 63.18
10 18 15 1.18 201.21 193.95 333.77 418.48 148.34 106.61 155.68 1.90 1,162.87 18 64.60
11 12 9 1.14 193.29 178.99 18
12 6 3 1.14 193.29 178.99 18
FORMULAS APLICADAS EN EL CLCULO: NOMENCLATURA DE VARIABLES:
Frz=c (z/10),c (/10),c APLICACIN DE VIENTO, SENTIDO CRITICO HACIA UNA SOLA PIERNA:
SEGN ALTURA ZP = ALTURA DE LA CARGA (M)
C
VD=FT x Frz x VR AP = REA PROYECTADA DE PIERNAS (M2) MICROONDA -------
2
qz=0.0047 x G x VD AT = REA TOTAL DE CADA SECCIN(M2) FEEDER ------------
G=(0.392*)/(273+ t) CA = COEFICIENTE DE ARRASTRE.
Feq=qz*Cat*Aref*FAD FNODAL = CARGA NODAL APLICADA AL PROGRAMA STAAD PRO(KG)
F NODAL= (FEQ / # NODOS) T = TEMPERATURA DE LA REGIN PROPUESTA (C)
FEQ=FUERZA DE ARRASTRE EN DIRECC. DEL VIENTO
A N B
FT = FACTOR TOPOGRFICO (SECC- 4.2.4)

VIENTO
RESUMEN DE FUERZAS DE VIENTO SOBRE LAS ANTENAS

Vc(KM/HR)
Fa (KG) Ficha
# ALTURA ALTURA ALTURA VD Ficha
PIERNA DESCRIPCIN DIMETRO (M) # NODOS Frz tcnica de P (KG)
Antenas EDIF (M) ANTENA (M) TOTAL (M) (KM/HR) tcnica de
antena
microonda

1 A MICROONDA 1.80 M 0.00 60.0060.00 1 (90) 1.36 230.81 200 647.32 862.09
1 B MICROONDA 1.20 M 0.00 72.0072.00 1 (0) 1.38 235.01 200 142.56 196.84
2 PARABOLAS Fam= FUERZA SOBRE ANTENA
Fam=qz*Gh*Ca*Aa
NOTA: PARA EL CLCULO DE LAS FUERZAS DE VIENTO SOBRE LAS ANTENAS TIPO MICROONDAS Y SECTORIALES ; SE CONSIDERARN TODAS DE FRENTE AL VIENTO 0 EXCEPTO 1 A 90 MW
( 1.20M) VEA ECUACIN SIGUIENTE (NORMA TELCEL 2007) :

DONDE "VD" ES LA VELOCIDAD DE DISEO SEGN LA ALTURA DE LA ANTENA, "Fa" y "Vc" SON LA FUERZA Y VELOCIDAD DE
CATALOGO RESPECTIVAMENTE .