Documentos de Académico
Documentos de Profesional
Documentos de Cultura
RESERVORIO 5 m3
RESERVORIO 5 m3
DATOS
PROYECTO : AGUA POTABLE COCHARCAS ACERO MUROS
EXPEDIENTE COCHARCAS ACERO VERTICAL = 1/2 Pulg.
ZONAL : APURIMAC DIAMETRO = 1.270 Cms.
EVALUADOR : CARLOS L AREA = 1.267 Cms2.
FECHA : 4-Jun-17 PESO = 0.994 Kg/ml
ACERO HORIZONTAL = 1/2 Pulg.
DIAMETRO = 1.270 Cms.
CARACTERISTICAS GEOMETRICAS AREA = 1.267 Cms2.
VOLUMEN RESERVORIO = 5.00 m3 PESO = 0.994 Kg/ml
ALTURA UTIL RESERVORI = 1.25 mts.
LADO UTIL RESERVORIO = 2.00 mts. ACERO LOSA DE TECHO
ESPECIFICACIONES ACERO HORIZONTAL = 1/2 Pulg.
CONCRETO f'c = 210 Kg/cm2 DIAMETRO = 1.270 Cms.
SOBRECARGA EN LOSA = 150 Kg/m2 AREA = 1.267 Cms2.
ACERO fy = 4,200 Kg/cm2 PESO = 0.994 Kg/ml
RESISTENCIA DEL SUELO = 1.00 Kg/cm2 ACERO LOSA DE FONDO
COEF. SISMICO = 0.12 ACERO HORIZONTAL = 1/2 Pulg.
RECUBRIMIENTO r = = 5.00 Cm DIAMETRO = 1.270 Cms.
fs = 2,100 Kg/cm2 AREA = 1.267 Cms2.
fc = 94.5 Kg/cm2 PESO = 0.994 Kg/ml
1.35
1.35
Sc Wc
SL 0.10
A' B'
0.30
WL NIVEL DE AGUA
S1
1.25
Ea
0.98 Wa
A B
S2 0.20
0.10
C D
W2
0.28
0.68
0.85
CALCULOS
W1= Pc x V1 558.00 Kg
W2 = Pc x V2 648.00 Kg
Wa = Pa x Va 1250.00 Kg
WL = Pc x VL 276.00 Kg
Ws = Sc x A 172.50 Kg
S1 = 0,12 x W1 100.44 Kg
S2 = 0,12 x W2 116.64 Kg
SL = 0,12 x WL 49.68 Kg
Ss = 0,12 x Ws 37.26 Kg
Ea = 1,12 x 0,5 x Pa x H12 1312.50 Kg
V = Fh / A 1.00 Kg/cm2
CALCULO DE LA ARMADURA
Mu 765.68 Kg-mts.
d = t1 - r - D/2 9.37 Cms.
AREA DE ACERO
As1 = 77.38 Cms2
As2 = 2.23 Cms2 SE ASUME : 2.23 Cms2
CUANTIA = As / t1 x b 0.0015
As = P x b x t1 2.70 Cms2
ACERO EN LA ZAPATA
P1 1904.4
P2 3850.2
P3 3348.00
P4 5248.80
P5 7500.00
Wu : 4400.70
CALCULO DEL MOMENTO ULTIMO
CUANTIA = As / t1 x b 0.00112
CUANTIA = As / t1 x b 0.00072
CUANTIA MINIMA POR FLEXION 0.0012 > 0.0007 MAL!! SE ASUME CUANTIA MINIMA P= 0.0012
As = P * t1 * b 1.20 Cms2
0.15 0.30
0.15
1.5 UNIONES
ELECTROSOLDADAS
0.10
2.00
ESCALINES FG
VER DETALLE
DETALLE DE ESCALINES
ESPECIFICACIONES TECNICAS
0.15 RESISTENCIA DEL CONCRETO f'c = 175 Kg/cm2
0.10
0.30
NIVEL DE AGUA
1/2 @ 0.30
1/2 @ 0.30
1/2 @ 0.25 PENDIENTE DE FONDO 1%
1/2 @ 0.30
0.20
0.075
2.30
2 3/8
2.30
PLANILLA DE ARMADURA RESERVORIO 5 M3
2.24
2.24
1.02
2.64
0.10
0.15
2.15 1/2 4.75 12.33 58.23
1.15
PESO TOTAL EN Kg 261.87
HOJA DE METRADOS DE RESERVORIO
CAPACIDAD : 5 M3
6.09 TARRAJEO INTERIOR CON IMPERMEABILIZANTE 4.00 2.00 1.55 12.40 16.40 m2
1.00 2.00 2.00 4.00 m2
6.10 TARRAJEO EXTERIOR MEZCLA 1:5 4.00 2.30 1.65 15.18 20.47 m2
1.00 2.30 2.30 5.29 m2
6.11 TAPA SANITARIA METALICA 0,60 x 0,60 Mts. 1.00 1.00 1.00 unid
6.12 TUBERIA DE VENTILACION FG D= 2" 1.00 1.00 1.00 unid
6.13 PRUEBA HIDRAULICA Y DESINFEC. RESERVORIO 1.00 1.00 1.00 glb
6.14 SUMINISTRO Y COLOCACION DE HIPOCLORADOR 1.00 1.00 1.00 unid
6.15 PINTADO DE MUROS EXTERIORES 4.00 2.30 1.65 15.18 20.47 m2
1.00 2.30 2.30 5.29