Está en la página 1de 4

DISEO DE MURO EN VO

PROYECTO :

CONSTRUCCION MURO EN VOL


INGRESAR DATOS: para =0

b
= 30 0.5 Radianes
= 0.5 4
c= 2.4 Ton/m3 1
m= 1.9 Ton/m3
qs= 20.00 Ton/m2

Desnivel H

h1=h-0.1h
6.00 m 3
2 6.400

h=H+Df
1

0.4000
m
0.72 2.74
Df

P=h/10min b''=0.1@0.12h T=B-(pie+b'')

d=0.1
1.2

h
4 0.80

B=0.4h @ 0.6h
4.32 m
1. RESULTADOS TEORICOS Y CRITERIO DE ASUMIR :
h BASE (B) PIE (h/10)min b''=.1h@.12h TALON d=0.1h
7.20 4.32 0.720 0.8640 2.736 0.72
RESULTADOS ASUMIDOS SOLO EN d:
h BASE (B) PIE (B/3) b''=0.1h TALON d=0.1h
7.20 4.32 0.720 0.86 2.736 0.80

2. COMPONENTES DE GRAVEDAD:
N Elemento (Ton/m3) Vol y L W (Ton) Xi
1 Triang. Muro 2.4 1.80 4.33 1.10
2 Frotal Muro 2.4 1.92 4.61 1.43
3 Relleno Talon 1.9 17.51 33.27 2.95
4 Losa Ciment. 2.4 3.46 8.29 2.16
5 Relleno Pie 1.9 0.29 0.55 0.36
6 Relleno Pie 1.9 0.01 0.01 0.73
7 s/c 2 Ton/m2 2.74 m 4.10 2.95
w 55.17 Mr
3. RESULTADOS TEORICOS:
Ka= 0.333 Pa= 4.56 Ton/m2/m
Kp= 3.00 Pp= 6.84 Ton/m2/m
/=(/)/""

hs/c= 0.79 m El empuje activo horizontal total sera:


Ps/c= 0.500 Ton/m /m
2
al area del trapecio de presiones
=+/ =((+/))/"2" =((2+3/))/3(+2/
Pat= 5.06 Ton/m2/m
Eah= 20.02 Ton/m
y= 2.62 m
4. UBICACION DE LA RESULTANTE DE FUERZA VERTICAL
=(())/("" )
nota: si Eha=o "a" cae casi en el centro de la losa
B/3 Si a=B/3 Si a < B/3 Si a > B/3
a= 1.59 m 1.44 0 0 Resultante fuera del terc

5. VERIFICACION POR VOLTEO 6. VERIFICACION POR DESLIZAMIENTO


= friccion suelo-hormigon
=
1=((4
Mv= 52.36 fsh= 27.58 Ton/m
=(())/ =((+))/
(() ) > 2 > 1.5
FSv= 2.67 FSd= 1.58 Ton/m
Cumple Cumple

8. CONSIDERANDO DENTELLON =*h'


Peso del dentellon trapeziodal Kp= 3.00
ancho= 1.5 =(^)/2
angulo= 45 0.8 Radianes Eph= 5.81 Ton/m
Profun.= 0.5 y= 0.57 m

Vdet= 0.50 m3 Wdet= 1.20 Ton


w 56.37 Ton
URO EN VOLADIZO

N MURO EN VOLADIZO
Ingresar
Asumir
Resultados

INGRESAR DATOS:
H= 6 m
Df= 1.2 m
b= 0.3 m
S/C= 1.50 Ton/m2

0.035
7.20
6
5
0.40

0.72 0.564 0.30


Pie=h/10 min m b

B=0.4h @ 0.6h

h1 Talud() m b
6.480 85.02568 0.56 0.30

h1 Talud() m b
6.400 85.03 0.56 0.30
0.500
*/=
hs/c *hs/c

Mr=W*Xi
4.75
6.61
98.21 3
h1

17.92 2
0.20
h

Eah
0.01
1
12.12 20.02
139.81
y 2.62 m
h'

Eph 1.2
4
=*h' *h=*h

5.06
El empuje pasivo horizontal total sera:
al area del triangulo de presiones
/))/3(+2/) =(^)/2

Eph= 4.10 Ton/m


y= 0.40 m

B/6= 0.72 condicion si e <= B/6 repartir carga


Exentr. e= 0.57 m uniforme a lo largo de la zapata
ante fuera del tercio medio repartir carga rectangular

7. VERIFICACION PRESIONES SUELO


=/2
Caso si a=B/3 1=2=/
1=((46))/^2 2=((62))/^2

22.97 2.57 12.77


Cumple
Caso si a< B/3 1=(2)/ 2=0 q1= 25.5 Ton/m2

Caso si a > B/31=(2)/(3) 2=0 q1= 23.2 Ton/m2


Presion suelo Corregir Burrazo

h'= 1.7
Pp= 9.69 Ton/m2/m

VERIFICACION POR DESLIZAMIENTO


friccion suelo-hormigon
=
fsh= 28.18 Ton/m
=((+))/
> 1.5
FSd= 1.70 Ton/m
Cumple