Está en la página 1de 7

Ao 2016 Mes 3 Da 31 Agente EEQ

Demanda frecuencia %duracin %Dpico


hora Demanda [kW] Di^2 frecuencia
ordenada acumulada eje x eje y
1 375883,947 1,41E+11 639287,249 1 1 4,17 100,00
2 350517,167 1,23E+11 619574,37 1 2 8,33 96,92
3 338021,819 1,14E+11 589451,016 1 3 12,50 92,20
4 341204,107 1,16E+11 558243,512 1 4 16,67 87,32
5 354957,643 1,26E+11 555025,894 1 5 20,83 86,82
6 425446,313 1,81E+11 543527,461 1 6 25,00 85,02
7 479781,618 2,30E+11 537779,822 1 7 29,17 84,12
8 465500,77 2,17E+11 536569,183 1 8 33,33 83,93
9 498875,338 2,49E+11 533340,305 1 9 37,50 83,43
10 526624,745 2,77E+11 531925,606 1 10 41,67 83,21
11 543527,461 2,95E+11 526624,745 1 11 45,83 82,38
12 555025,894 3,08E+11 522327,601 1 12 50,00 81,70
13 537779,822 2,89E+11 515613,357 1 13 54,17 80,65
14 531925,606 2,83E+11 498875,338 1 14 58,33 78,04
15 536569,183 2,88E+11 479781,618 1 15 62,50 75,05
16 533340,305 2,84E+11 476810,767 1 16 66,67 74,58
17 522327,601 2,73E+11 465500,77 1 17 70,83 72,82
18 515613,357 2,66E+11 425446,313 1 18 75,00 66,55
19 589451,016 3,47E+11 400898,993 1 19 79,17 62,71
20 639287,249 4,09E+11 375883,947 1 20 83,33 58,80
21 619574,37 3,84E+11 354957,643 1 21 87,50 55,52
22 558243,512 3,12E+11 350517,167 1 22 91,67 54,83
23 476810,767 2,27E+11 341204,107 1 23 95,83 53,37
24 400898,993 1,61E+11 338021,819 1 24 100,00 52,87
Total(da) 11717188,6 5,90E+12
*Demanda en cada hora es numricamente igual a la E consumida en esa hora.
Promedio [kW] 4,88E+05
Pico [kW] 6,39E+05

Regresin exponencial: y = 103,96e-0,006x C=50


A=53,96
B=0,006

11717188,603
= 100 = 76,37
639287,249 24
5,90E+12
=
639287,2492 24
E: fp=0,6374
= 0,6015
A: fp=0,6554
700000
639287,249

600000

500000

400000

300000

200000

100000

0
0 5 10 15 20 25 30
Curva de carga diaria: eje y
120,00

100,00

Regresin exponencial y = 103,96e-0,006x


80,00

60,00

40,00

20,00

0,00
0,00 20,00 40,00 60,00 80,00 100,00 120,00
Ao 2016 Mes 3 Da 1 Agente EEQ

Demanda frecuencia %duracin %Dpico


hora Demanda [kW] Di^2 frecuencia
ordenada acumulada eje x eje y
1 76.254,34 5,81E+09 81570,214 1 1 4,17 100,00
2 73.930,50 5,47E+09 80839,855 1 2 8,33 99,10
3 70.095,24 4,91E+09 77173,803 1 3 12,50 94,61
4 66.463,24 4,42E+09 76254,341 1 4 16,67 93,48
5 63.166,34 3,99E+09 73930,499 1 5 20,83 90,63
6 60.901,39 3,71E+09 73175,622 1 6 25,00 89,71
7 55.483,43 3,08E+09 71492,25 1 7 29,17 87,65
8 52.908,33 2,80E+09 70095,241 1 8 33,33 85,93
9 54.777,12 3,00E+09 66569,762 1 9 37,50 81,61
10 57.342,30 3,29E+09 66463,243 1 10 41,67 81,48
11 59.089,08 3,49E+09 63166,343 1 11 45,83 77,44
12 60.369,81 3,64E+09 62385,695 1 12 50,00 76,48
13 60.301,76 3,64E+09 61272,111 1 13 54,17 75,12
14 61.272,11 3,75E+09 61114,698 1 14 58,33 74,92
15 60.936,49 3,71E+09 60936,488 1 15 62,50 74,70
16 61.114,70 3,74E+09 60901,385 1 16 66,67 74,66
17 60.820,63 3,70E+09 60820,632 1 17 70,83 74,56
18 62.385,70 3,89E+09 60369,812 1 18 75,00 74,01
19 73.175,62 5,35E+09 60301,756 1 19 79,17 73,93
20 81.570,21 6,65E+09 59089,077 1 20 83,33 72,44
21 80.839,86 6,54E+09 57342,3 1 21 87,50 70,30
22 77.173,80 5,96E+09 55483,427 1 22 91,67 68,02
23 71.492,25 5,11E+09 54777,122 1 23 95,83 67,15
24 66.569,76 4,43E+09 52908,328 1 24 100,00 64,86
Total(da) 1.568.434,00 1,04E+11
*Demanda en cada hora es numricamente igual a la E consumida en esa hora.
Promedio [kW] 6,54E+04
Pico [kW] 81.570,21

Regresin exponencial: y = 98,523e-0,004x C=50


A=48,523
B=0,004

1568434
= 81570,2124 100 =80,12%

1,04E+11
=
81570,212 24
E: fp=0,6897
= 0,6512
A: fp=0,7056
Demanda [kW]
90000

80000

70000

60000

50000

40000

30000

20000

10000

0
0 5 10 15 20 25 30
Curva de carga diaria: eje y
120,00

y = 98,523e-0,004x
100,00

80,00

60,00

40,00

20,00

0,00
0,00 20,00 40,00 60,00 80,00 100,00 120,00