Suva refrigerants

Pocket Reference Guide


Typical
pH Diagram

Superheat

Saturated Vapor
Pressures

Superheat
Reference Point

Dew
Point

Dew PointSaturated Vapor (psig)

Suva
F Suva Suva Suva Suva 407C Suva Suva C
MP39 MP66 HP80 HP81 (9000) 408A 409A
(R-401A) (R-401B) (R-402A) (R-402B) (R-407C) (R-408A) (R-409A)
50
48
46
44
42

18.4"
17.6"
16.9"
16.1"
15.2"

17.2"
16.4"
15.5"
14.7"
13.8"

1.0
1.8
2.7
3.7
4.6

1.1"
0.3
1.1
1.9
2.8

11.2"
10.0"
8.9"
7.6"
6.3"

2.5"
1.0"
0.3
1.1
1.9

18.6"
17.9"
17.1"
16.4"
15.6"

46
44
43
42
41

40
38
36
34
32

14.3"
13.4"
12.4"
11.4"
10.3"

12.8"
11.8"
10.7"
9.6"
8.5"

5.6
6.7
7.8
8.9
10.0

3.7
4.7
5.7
6.7
7.8

4.9"
3.5"
2.0"
0.4"
0.6

2.8
3.7
4.6
5.6
6.6

14.7"
13.8"
12.9"
11.9"
10.9"

40
39
38
37
36

30
28
26
24
22

9.2"
8.1"
6.9"
5.6"
4.3"

7.3"
6.0"
4.7"
3.3"
1.9"

11.3
12.5
13.8
15.2
16.6

8.9
10.1
11.3
12.5
13.8

1.4
2.3
3.2
4.2
5.2

7.6
8.7
9.8
11.0
12.2

9.9"
8.8"
7.6"
6.4"
5.2"

34
33
32
31
30

20
18
16
14
12

2.9"
1.5"
0.0
0.8
1.6

0.4"
0.6
1.3
2.2
3.0

18.0
19.5
21.1
22.7
24.4

15.2
16.6
18.0
19.5
21.0

6.2
7.3
8.4
9.5
10.7

13.4
14.7
16.1
17.5
18.9

3.8"
2.5"
1.1"
0.2
0.9

29
28
27
26
24

10
8
6
4
2

2.4
3.2
4.1
5.0
6.0

3.9
4.8
5.8
6.8
7.8

26.1
27.9
29.7
31.6
33.5

22.6
24.3
26.0
27.7
29.5

12.0
13.3
14.6
16.0
17.4

20.4
22.0
23.6
25.2
26.9

1.7
2.5
3.4
4.3
5.2

23
22
21
20
19

0
2
4
6
8

7.0
8.0
9.1
10.2
11.3

8.9
10.0
11.1
12.3
13.5

35.6
37.6
39.8
42.0
44.3

31.4
33.3
35.3
37.4
39.5

18.9
20.5
22.1
23.7
25.4

28.7
30.5
32.3
34.3
36.3

6.1
7.1
8.1
9.2
10.3

18
17
16
14
13

10
12
14
16
18

12.5
13.7
15.0
16.3
17.6

14.8
16.1
17.4
18.8
20.3

46.6
49.0
51.5
54.0
56.7

41.7
43.9
46.2
48.6
51.1

27.2
29.0
30.9
32.9
34.9

38.3
40.4
42.6
44.9
47.2

11.4
12.6
13.8
15.0
16.3

12
11
10
9
8

20
22
24
26
28

19.0
20.5
22.0
23.5
25.1

21.8
23.3
24.9
26.5
28.2

59.4
62.2
65.0
68.0
71.0

53.6
56.2
58.8
61.6
64.4

37.0
39.1
41.3
43.6
46.0

49.5
52.0
54.5
57.1
59.8

17.6
19.0
20.5
21.9
23.4

7
6
4
3
2

30
32
34
36
38

26.7
28.4
30.1
31.9
33.7

30.0
31.8
33.5
35.5
37.5

74.1
77.3
80.5
83.9
87.3

67.3
70.3
73.3
76.4
79.7

48.4
50.9
53.5
56.2
58.9

62.5
65.3
68.2
71.2
74.2

25.0
26.6
28.3
30.0
31.8

1
0
1
2
3

40
42
44
46
48
50

35.6
37.6
39.6
41.7
43.8
46.0

39.5
41.6
43.7
45.9
48.2
50.5

90.9
94.5
98.2
102.0
106.0
110.0

83.0
86.4
89.8
93.4
97.1
100.8

61.7
64.6
67.6
70.7
73.8
77.1

77.4
80.6
83.9
87.3
90.7
94.3

33.6
35.5
37.5
39.5
41.5
43.6

4
6
7
8
9
10

"Denotes inches of mercury ("Hg)


To obtain the Dew Point of saturated refrigerants above 50F
(10C), use its Bubble Point temperature plus the value listed
below:
MP series use 10F (5C), 9000 use 11F (6C), HP80 and HP81
use 2F (1C), 409A use 15F (8C), 408A use 1F (0.6C).
Bubble
Point
Typical
pH Diagram

Subcooling
Saturated Liquid
Pressures

Subcooling
Reference Point

Bubble PointSaturated Liquid (psig)

Suva
F Suva Suva Suva Suva 407C Suva Suva C
MP39 MP66 HP80 HP81 (9000) 408A 409A
(R-401A) (R-401B) (R-402A) (R-402B) (R-407C) (R-408A) (R-409A)
50
55
60

58
64
71

62
69
76

114
125
136

106
116
126

96
106
116

96
105
115

61
67
74

10
13
16

65
70
75

78
86
94

84
92
101

148
161
174

138
150
162

127
139
151

126
137
149

82
90
98

18
21
24

80
85
90

103
112
122

110
119
130

188
203
218

175
189
204

163
177
191

161
174
188

107
116
126

27
29
32

95
100
105

132
143
154

140
152
164

235
252
270

220
236
253

206
222
239

203
219
235

137
148
159

35
38
41

110
115
120

166
179
192

176
190
203

289
309
330

271
290
310

257
275
294

252
270
289

172
184
198

43
46
49

125
130
135

206
220
236

218
233
249

353
376
400

330
352
375

315
336
358

309
330
351

212
227
242

52
54
57

140
145
150

252
268
286

266
284
302

425
451
479

399
423
449

381
405
430

374
398
423

258
275
293

60
63
66

To obtain the Bubble Point of saturated refrigerants below


50F (10C), use its Dew Point temperature minus the value
listed below:
MP series use 10F (5C), 9000 use 11F (6C), HP80 and HP81
use 2F (1C), 409A use 15F (8C), 408A use 1F (0.6C).
Suva is a registered trademark of DuPont.

DuPont Fluorochemicals
Wilmington, Delaware 19880-0711
(800) 235-SUVA
In Canada (800) USESUVA

Suva refrigerants

Pocket Reference Guide

Saturated ConditionsPressure (psig)

Suva Suva
F Freon Suva Suva Suva 410A
507 Suva
22
123
134a HP62 (9100) (AZ-50) 95
C
(R-22) (R-123) (R-134a) (R-404A) (R-410A) (R-507) (R-508B)
120
115
110
105
100

3.0
5.9
9.2
12.8
16.9

84.8
81.7
78.9
76.1
73.3

95
90
85
80
75

10.2"

21.4
26.4
31.9
37.9
44.5

70.6
67.8
65.0
62.2
59.4
56.7
53.9
51.1
48.3
45.6

70
65
60
55
50

12.4"
9.7"
6.6"

19.1"

0.2

7.0"
3.4"
0.3
2.5
5.0

0.9

51.5
59.6
68.1
77.3
87.3

48
46
44
42
40

5.3"
3.9"
2.5"
1.0"
0.5"

18.4"
17.7"
16.9"
16.1"
15.2"

1.0
1.8
2.7
3.6
4.6

6.1
7.2
8.3
9.5
10.8

1.8
2.7
3.6
4.6
5.6

91.5
95.8
100
105
109

44.4
43.3
42.2
41.1
40.0

38
36
34
32
30

1.1
1.9
2.8
3.7
4.7

14.3"
13.4"
12.4"
11.3"
10.2"

5.6
6.6
7.7
8.8
9.9

12.1
13.4
14.9
16.3
17.8

6.6
7.7
8.8
10.0
11.2

114
119
124
129
135

38.9
37.8
36.7
35.6
34.4

28
26
24
22
20

5.7
6.7
7.8
8.9
10.0

9.1"
7.9"
6.6"
5.3"
4.0"

11.1
12.4
13.7
15.0
16.4

19.4
21.0
22.7
24.5
26.3

12.5
13.8
15.1
16.5
18.0

140
146
152
158
164

33.3
32.2
31.1
30.0
28.9

18
16
14
12
10

11.2
12.4
13.7
15.0
16.4

2.5"
1.1"
0.2
1.0
1.9

17.8
19.3
20.8
22.4
24.0

28.2
30.1
32.1
34.2
36.4

19.5
21.0
22.6
24.3
26.0

170
177
184
191
198

27.8
26.7
25.6
24.4
23.3

8
6
4
2
0

17.8
19.3
20.8
22.4
24

2.7
3.6
4.5
5.5
6.5

25.7
27.4
29.2
31.1
33.0

38.6
40.9
43.3
45.7
48.2

27.8
29.6
31.4
33.4
35.4

205
212
220
227
235

22.2
21.1
20.0
18.9
17.8

2
4
6
8
10

25.7
27.4
29.2
31.0
32.9

7.5
8.6
9.7
10.8
12.0

35.0
37.0
39.1
41.3
43.5

50.8
53.5
56.3
59.2
62.1

37.4
39.5
41.7
44.0
46.3

244
252
260
269
278

16.7
15.6
14.4
13.3
12.2

12
14
16
18
20

34.8
36.8
38.9
41.0
43.2

22.8"

13.2
14.5
15.8
17.2
18.6

45.8
48.2
50.6
53.1
55.7

65.2
68.3
71.5
74.8
78.2

48.6
51.1
53.6
56.2
58.8

287
297
307
316
326

11.1
10.0
8.9
7.8
6.7

22
24
26
28
30

45.5
47.8
50.2
52.6
55.1

22.4"
22.0"
21.6"
21.2"
20.8"

20.0
21.5
23.1
24.7
26.3

58.4
61.1
63.9
66.8
69.7

81.7
85.3
89.1
92.9
96.8

61.6
64.4
67.3
70.2
73.3

336
346
357
368
379

5.6
4.4
3.3
2.2
1.1

32
34
36
38
40

57.7
60.4
63.1
65.9
68.7

20.3"
19.9"
19.4"
18.8"
18.3"

28.0
29.7
31.5
33.4
35.3

72.8
75.9
79.1
82.4
85.7

101
105
109
114
118

76.4
79.6
82.9
86.2
89.7

390
402
414
426
438

0
1.1
2
3.3
4.4

42
44
46
48
50

71.7
74.7
77.8
81.0
84.2

17.7"
17.1"
16.5"
15.9"
15.2"

37.3
39.3
41.4
43.5
45.7

89.2
92.7
96.4
100.1
103.9

123
127
132
137
142

93.2
96.9
100.6
104.4
108.3

451
464
477
490
504

5.6
6.7
7.8
8.9
10.0

55
60
65
70
75

92.7
102
111
122
132

13.4"
11.4"
9.3"
6.9"
4.3"

51.5
57.7
64.3
71.3
78.9

114
124
136
148
160

156
170
185
200
217

119
129
141
153
166

539

12.8
15.6
18.3
21.1
23.9

86.9
95.4
104
114
124

174
188
203
218
235

235
254
274
295
317

180
194
210
226
243

26.7
29.4
32.2
35.0
37.8

80
85
90
95
100

144
156
168
182
196

1.5"
0.8
2.4
4.2
6.1

105
110
115
120
125

210
226
242
260
278

8.1
10.3
12.7
15.2
17.8

135
146
158
171
184

252
270
290
310
331

340
364
390
417
445

261
280
300
322
344

40.6
43.3
46.1
48.9
51.7

130
135
140
145
150

296
316
337
359
381

20.7
23.7
27.0
30.4
34.0

199
213
229
246
263

353
376
401
426
453

475
506
538
573
608

368
392
418
446
475

54.4
57.2
60.0
62.8
65.6

"Denotes inches of mercury ("Hg)


Eight Easy Steps to Retrofit
From CFC-12 to Suva MP39, Suva 409A, or Suva MP66
From R-502 to Suva HP80, Suva 408A, or Suva HP81
1. Establish baseline performance with CFC.
2. Remove CFC from the system into a recovery cylinder.
Weigh the amount removed if possible.
3. Drain mineral oil from the system and measure the
volume removed. (Skip steps 3 and 4 if alkylbenzene is
already in the system or you are not changing the mineral
oil.) Field experience has shown that Suva MP39, 409A,
MP66, and HP81 work successfully with the existing
mineral oil in many unitary and other close-coupled
systems where oil return is not a concern.
4. Add alkylbenzene lubricant; use the same volume as
removed in step 3.
5. Replace filter/drier.
6. Evacuate system and check for leaks.
7. Charge with Suva refrigerant.
Remove liquid only from charging cylinder
Typical charge is 7590% of CFC charge
8. Start up the system.
Adjust charge size
Label system for the refrigerant and lubricant used
See Retrofit Guidelines For Full Details