PG Test Instrument Schedule

S. No. Service NTPC PTC-6 (Y/N) ALSTOM Sensor Sensor


approved Schematic (NTPC) (Alstom)
BHEL
A. POINTS WITH WELDED THERMOWELL
1 MS (L) BEF STRAINER Y Y Y K-TC K-TC
2 MS (L) BEF STRAINER Y Y Y K-TC K-TC
3 MS (R) BEF STRAINER Y Y Y K-TC K-TC
4 MS (R) BEF STRAINER Y Y Y K-TC K-TC
5 CRH(L) BEF NRV Y Y Y K-TC K-TC
6 CRH(L) BEF NRV Y Y Y K-TC K-TC
7 CRH(R) BEF NRV Y Y Y K-TC K-TC
8 CRH(R) BEF NRV Y Y Y K-TC K-TC
9 HRH(L) BEF STRAINER Y Y Y K-TC K-TC
10 HRH(L) BEF STRAINER Y Y Y K-TC K-TC
11 HRH(R) BEF STRAINER Y Y Y K-TC K-TC
12 HRH(R) BEF STRAINER Y Y Y K-TC K-TC
13 IPT-EXH FL Y Y Y K-TC K-TC
14 IPT-EXH RL Y Y Y K-TC K-TC
15 IPT-EXH FR Y Y Y K-TC K-TC
16 IPT-EXH RR Y Y Y K-TC K-TC
17 LPT-INLET (L) Y Y N K-TC K-TC
18 LPT-INLET (L) Y Y N K-TC K-TC
19 LPT-INLET (R) Y Y N K-TC K-TC
20 LPT-INLET (R) Y Y N K-TC K-TC
21 EXT TO DEA (TE) Y Y N K-TC K-TC
22 EXT TO HPH5 (TE) Y Y Y K-TC K-TC
23 HP BYPASS (L) BFR SPRAY ? ? NA K-TC K-TC
24 HP BYPASS (R) BFR SPRAY ? ? NA K-TC K-TC
25 EXT TO DEA (HE) Y Y Y K-TC K-TC
26 EXT TO DEA (HE) Y Y Y K-TC K-TC
27 BFPD NR PUMP-A Y N Y PRT K-TC
28 BFPD NR PUMP-B Y N Y PRT K-TC
29 BFPD NR PUMP-C Y N Y PRT K-TC
30 BFPD HPH5 INLET Y Y Y PRT K-TC
31 BFPD HPH5 INLET Y Y Y PRT K-TC
32 EXT TO HPH5 (HE) Y Y Y K-TC K-TC
33 EXT TO HPH5 (HE) Y Y Y K-TC K-TC
34 BFDP-HPH 5 OUTLET Y Y Y PRT K-TC
35 BFDP-HPH 5 OUTLET Y Y Y PRT K-TC
36 BFDP-HPH 6 INLET Y Y Y PRT K-TC
37 BFDP-HPH 6 INLET Y Y Y PRT K-TC
38 HPH 6 DRAIN (HE) Y Y Y PRT K-TC
39 HPH 6 DRAIN (HE) Y Y Y PRT K-TC
40 EXT TO HPH6 (HE) Y Y Y K-TC K-TC
41 EXT TO HPH6 (HE) Y Y Y K-TC K-TC
42 BFPD HPH6 OUTLET Y Y Y PRT K-TC
43 BFPD HPH6 OUTLET Y Y Y PRT K-TC
44 BFPD AFTER RCV ? ? ? PRT K-TC
45 BFPD-ECON INLET ? ? ? PRT K-TC
46 RH SPRAY Y NA NA PRT K-TC
47 BFPD AFTER RCV ? ? ? PRT K-TC
48 CRH-BFR RH SPRAY MIX (L) Y NA NA K-TC K-TC
49 CRH-BFR RH SPRAY MIX (L) Y NA NA K-TC K-TC
50 CRH-BFR RH SPRAY MIX (R) Y NA NA K-TC K-TC
51 CRH-BFR RH SPRAY MIX (R) Y NA NA K-TC K-TC
52 HP EXHAUST (L) Y Y Y K-TC K-TC
53 HP EXHAUST (R) Y Y Y K-TC K-TC
B. POINTS WITH SCREWED TYPE THERMOWELL & M33*2 STUB
54 LPT EXHAUST Y N Y PRT K-TC
55 LPT EXHAUST Y N Y PRT K-TC
56 LPT EXHAUST Y N Y PRT K-TC
57 LPT EXHAUST Y N Y PRT K-TC
58 EXT TO LPH3 (TE) Y Y N PRT K-TC
59 EXT TO LPH2 (TE) Y Y N PRT K-TC
60 LP BYPASS (L) Y NA NA PRT K-TC
61 LP BYPASS (R) Y NA NA PRT K-TC
62 DEA SHELL Y N N PRT K-TC
63 HPH5 DRAIN NR HEATER Y Y Y PRT K-TC
64 HPH5 DRAIN NR HEATER Y Y Y PRT K-TC
65 HPH5 DRAIN NR DEA Y Y Y PRT K-TC
66 HPH5 DRAIN NR DEA Y Y Y PRT K-TC
67 CEPD-NR DEA ? ? ? PRT K-TC
68 CEPD-NR DEA ? ? ? PRT K-TC
69 CEPD-NR FE 101 ? ? ? PRT K-TC
70 CEPD- AFTER LPH3 BYPASS Y NA NA PRT K-TC
71 CEPD- LPH3 OUTLET Y Y N PRT K-TC
72 EXT TO LPH3 (HE) Y Y Y PRT K-TC
73 CEPD-LPH3 INLET Y Y N PRT K-TC
74 LPH3 DRAIN Y Y NA PRT K-TC
75 CEPD-LPH2 OUTLET Y Y NA PRT K-TC
76 EXT TO LPH2 (HE) Y Y Y PRT K-TC
77 CEPD-LPH2 INLET Y Y N PRT K-TC
78 LPH2 DRAIN Y Y NA PRT K-TC
79 CEPD-LPH1 OUTLET Y Y Y PRT K-TC
80 CEPD-DC OUTLET Y Y NA PRT K-TC
81 LPH1 DRAIN Y Y NA PRT K-TC
82 DC DRAIN Y Y NA PRT K-TC
83 CEPD-DC INLET Y Y NA PRT K-TC
84 CEPD-GSC OUTLET Y N NA PRT K-TC
85 CEPD-GSC INLET Y N NA PRT K-TC
86 AIR/STM MIX TO GSC Y N NA PRT K-TC
87 GSC DRAIN Y N NA PRT K-TC
88 CW INLET (F) Y N Y PRT K-TC
89 CW INLET (F) Y N Y PRT K-TC
90 CW OUTLET (F) Y N Y PRT K-TC
91 CW OUTLET (F) Y N Y PRT K-TC
92 CW OUTLET (F) Y N Y PRT K-TC
93 CW OUTLET (F) Y N Y PRT K-TC
94 CW OUTLET (F) Y N Y PRT K-TC
95 CW OUTLET (F) Y N Y PRT K-TC
96 CW OUTLET (F) Y N Y PRT K-TC
97 CW OUTLET (F) Y N Y PRT K-TC
98 CW OUTLET (F) Y N Y PRT K-TC
99 CW INLET (R) Y N Y PRT K-TC
100 CW INLET (R) Y N Y PRT K-TC
101 CW OUTLET (R) Y N Y PRT K-TC
102 CW OUTLET (R) Y N Y PRT K-TC
103 CW OUTLET (R) Y N Y PRT K-TC
104 CW OUTLET (R) Y N Y PRT K-TC
105 CW OUTLET (R) Y N Y PRT K-TC
106 CW OUTLET (R) Y N Y PRT K-TC
107 CW OUTLET (R) Y N Y PRT K-TC
108 CW OUTLET (R) Y N Y PRT K-TC
109 CW OUTLET (R) Y N Y PRT K-TC
110 CEP SUCTION Y Y Y PRT K-TC
111 CEP SUCTION Y Y Y PRT K-TC
112 BFP SUCTION-A Y Y Y PRT K-TC
113 BFP SUCTION-B Y Y Y PRT K-TC
114 BFP SUCTION-C Y YY Y PRT K-TC
115 BFP SUCTION-A Y Y Y PRT K-TC
116 BFP SUCTION-B Y Y Y PRT K-TC
117 BFP SUCTION-C Y Y Y PRT K-TC
118 CEPD-NR FE 101 ? ? ? PRT K-TC
119 GLAND SEAL TO IP EXHAIUST Y Y NA K-TC K-TC
120 GLAND SEAL TO IP EXHAIUST Y Y NA K-TC K-TC
C. HIGH PRESSURE POINT WITH DOUBLE ROOT VALVE
121 MS (L) PR BFR STRAINER Y Y N PG
122 MS (R) PR BFR STRAINER Y Y N PG
123 FIRST STAGE PRESSURE Y Y N PG
124 CRH PR (L) BEF NRV Y Y N PG
125 CRH PR (R) BEF NRV Y Y N PG
126 HRH PR (L) Y Y N PG
127 HRH PR (R) Y Y N PG
128 EXT TO HPH 6 (HE) PR Y Y N PG
129 BFPD-A PR Y Y Y PG
130 BFPD-B PR Y Y Y PG
131 BFPD-C PR Y Y Y PG
132 BFPD-HPH5 INLET Y Y N PG
133 BFPD-HPH5 OUTLET Y N N PG
134 BFPD-HPH6 INLET Y N N PG
135 BFPD-HPH6 OUTLET Y N N PG
136 HPH6 DRAIN PRESSURE TO HPH5 Y N N PG
137 RH SPRAY PR Y N NA PG
138 HP BYPASS PR (R) ? NA NA PG
139 HP BYPASS PR (L) ? NA NA PG
D. LOW PRESSURE POINT WITH SINGLE ROOT VALVE
140 IPT-EXH FL PR Y Y Y PG
141 IPT-EXH RL PR Y Y Y PG
142 IPT-EXH FR PR Y Y Y PG
143 IPT-EXH RR PR Y Y Y PG
144 LPT INLET (L) PR Y Y N PG
145 LPT INLET (R) PR Y Y N PG
146 EXT TO DEA (TE) PR Y Y N PG
147 EXT TO DEA (HE) PR Y Y Y PG
148 DEA SHELL PRESSURE Y Y N PG
149 HPH 5 DR TO DEA (HE) Y N N PG
150 HPH 5 DR PR (NR DEA) Y N N PG
151 LP BYPASS (L) PR Y NA NA PG
152 LP BYPASS (R) PR Y NA NA PG
153 EXT TO LPH3 (TE) PR Y Y N PG
154 EXT TO LPH2 (TE) PR Y Y N MM
155 EXT TO LPH1 (TE) PR Y Y N MM
156 EXT TO LPH1 (TE) PR Y Y N MM
157 EXT TO LPH3 (HE) PR Y Y Y PG
158 EXT TO LPH2 (HE) PR Y Y Y MM
159 EXT TO LPH1 (HE) PR Y Y Y MM
160 AIR/ STM MIX TO GSC PR Y N NA MM
161 CEPD NEAR FE ? ? ? PG
162 CW INLET PR Y N N DM
163 CW OUTLET PR Y N N
164 CW INLET PR Y N N DM
165 CW OUTLET PR Y N N
166 COND VACCUUM Y N N MM
167 COND VACCUUM Y N N MM
168 COND VACCUUM Y N N MM
169 COND VACCUUM Y N N MM
170 COND VACCUUM Y N N MM
171 COND VACCUUM Y N N MM
172 COND VACCUUM Y N N MM
173 COND VACCUUM Y N N MM
174 CEP SUCTION PR Y N N MM
175 CEP SUCTION PR Y N N MM
176 CEPD PR DC INLET Y Y N PG
177 BFP-A SUCTION PR Y N N PG
178 BFP-B SUCTION PR Y N N PG
179 BFP-C SUCTION PR Y N N PG
180 GLAND SEAL TP IP PR Y Y N PG
181 EXT TO HPH5 (TE) Y Y Y PG
182 EXT TO HPH5 (HE) Y Y Y PG
E. FLOW MEASURING POINTS
183 MC FLOW TO DEA 1 ? N N D MM
184 MC FLOW TO DEA 2 ? N N D MM
185 RH SPRAY Y NA NA D MM
186 GLND STM A TO IP EXH Y N NA D MM
F. POWER MEASURING POINTS
187 GENERATOR POWER Y Y Y PM
188 BFP AUX POWER Y N N WM
189 CEP AUX POWER Y N N WM
190 ACW AUX POWER Y N N WM

NA Not applicable in schematic


Y Present in Schematic
N Not present in Schematic