Documentos de Académico
Documentos de Profesional
Documentos de Cultura
LOG-LOG
CALCULO DEL COEFICIENTE DE ALMACENAJE:
Q
T
24
P
C=
1001.35
1
24
C=
87
C=0.065 BBL/PSI
b. SEMILOG HORNER
CALCULO DE LA PENDIENTE (m):
m=
P
PsupPinf
=
CICLOS
CICLOS
m=
29852962
2
K=
162.6Q
mh
K=
162.61001.350.8
11,520
K=76.35 md
CALCULO DEL FACTOR SKIN (S):
S=1.151
P 1 HrPinf
K
log
+ 3.23
m
rw 2
S=1.151
29852859.2
76.35
log
+3.23
11 .5
0.120.815.61060.332
Ps= 0.87*m*S
Ps=0.8711.56.329
Ps=63.322 PSI
c. SEMILOG MDH
m=
P
PsupPinf
=
CICLOS
CICLOS
m=
29872963
1
P =P 1 hr +mlog(TP+1)
P =2987+ 12log(132.2+1)
P =3012.49 PSI
CALCULO DE LA PERMEABILIDAD (K):
K=
162.6Q
mh
K=
162.61001.350.8
1220
K=73.17 md
S=1.151
P 1 HrPinf
K
log
+ 3.23
m
rw 2
S=1.151
29872963
73.17
log
+3.23
6
2
12
0.120.815.610 0.33
Ps= 0.87*m*S
Ps=0.8712(3.93)
Ps=6.84 Psi
Log-Log
1000
P(Psi)
100
P(psi)
10
0.01
0.1
10
t (Horas)
100
1000
Semilog-(HORNER)
2990
2980
2970
2960
2950
Pwf (Psi)
2940
Pwf (Psi)
2930
2920
2910
2900
1.0
10.0
100.0
(Tp+T)/T
1000.0
Semilog MDH
3000
2980
2960
Pwf (psi)
2940
Pwf (psi)
2920
2900
2880
0.01
0.1
10
t (Horas)
100