Documentos de Académico
Documentos de Profesional
Documentos de Cultura
E-030 Edificaciones (Tablas) - Examen
E-030 Edificaciones (Tablas) - Examen
DIMENSIONES
"Eje x"
1.2 m
21 m
17 m
3.3 m
7m
0.4
3.3 m
4
357 m2
(Nmero de pisos)
OTROS
Esquina :
Ax
By
Area 1
Area Techada 1
7m
7m
c1
c7
c7
c1
c3
c5
c5
c3
c4
c6
c6
c4
c2
c8
c8
c2
C 1E
C 1E
C 1E
C 1E
C 1E
C 2C
C 2C
C 1E
C 1E
C 2C
C 2C
C 1E
C 1E
C 1E
C 1E
C 1E
7m
"Eje y"
Df (m) =
X (m) =
Y (m) =
H1 (m) =
Hi (m) =
N=
Area Total=
5m
5m
0m
0m
m2
357.00 m2
PREDIMENSIONAMIENTO
VIGAS
V1
V2
L2
TIPO
C 1E
C 2C
h (m) =
b (m) =
h (m) =
b (m) =
0.70
0.35
0.50
0.70
0.50
idem
0.25
idem
LOSA ALIGERADA
0.28
e (m) =
0.30
P (kg/m2)
Area (m2)
1000
1000
24.50
35.00
COLUMNAS
f`c (kg/cm2)
N
210
210
4
4
a (cm)
a=f(hv)
a (m)
0.37
0.38
0.49
0.49
0.50
0.50
METRADO DE CARGAS
RESUMEN
PISO
1
2
3
4
TOTAL
CM (TON)
CV (TON)
262.26
262.26
262.26
262.26
85.50
85.50
85.50
35.70
1049.04
PISO 4
Losa Aligerada
N
Columnas
16
N
Viga
Transversal
"Y"
Viga
Longuitud.
"X"
P (TON)
348
348
348
298
292.20
1,341
284
284
284
271
1,122
Peso (ton/m2)
rea (m2)
0.42
285.00
P concreto
(ton/m3)
PESO (ton.)
119.700
Lado 1 (m)
Lado 2 (m)
Altura (m)
2.4
P concreto
(ton/m3)
0.50
0.50
2.60
Base (m)
Peralte (m)
Luz (m)
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
6.50
6.50
6.50
6.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
CM (ton) =
s/c (ton/m2)
Techo
Ps (TON)
0.1
CV (ton) =
PESO (ton.)
24.960
PESO (ton.)
5.460
5.460
5.460
5.460
3.780
3.780
3.780
3.780
3.780
3.780
3.780
3.780
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
262.260
rea (m2)
357.00
35.700
35.700
PISO 3, 2 Y 1
Losa Aligerada
N
Columnas
16
N
Viga
Transversal
"Y"
Viga
Longuitud.
"X"
Vivienda
Tabiquera movil
Peso (ton/m2)
rea (m2)
0.42
285.00
P concreto
(ton/m3)
PESO (ton.)
119.700
Lado 1 (m)
Lado 2 (m)
Altura (m)
2.4
P concreto
(ton/m3)
0.50
0.50
2.60
Base (m)
Peralte (m)
Luz (m)
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
2.4
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.50
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
0.70
6.50
6.50
6.50
6.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
4.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
6.50
CM (ton) =
s/c (ton/m2)
rea (m2)
0.2
0.1
285.00
285.00
CV (ton) =
PESO (ton.)
24.960
PESO (ton.)
5.460
5.460
5.460
5.460
3.780
3.780
3.780
3.780
3.780
3.780
3.780
3.780
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
5.460
262.260
57.000
28.500
85.500
Yi
Ai
Xi x Ai
Yi x Ai
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
0
7
0
0
0.25
0.25
0.00
1.75
0.00
0.00
14
21
0
0
0
5
0.25
0.25
0.25
3.50
5.25
0.00
0.00
0.00
1.25
7
14
21
5
5
5
0.25
0.25
0.25
1.75
3.50
5.25
1.25
1.25
1.25
0
7
14
10
10
10
0.25
0.25
0.25
0.00
1.75
3.50
2.50
2.50
2.50
21
0
7
14
21
10
17
17
17
17
0.25
0.25
0.25
0.25
0.25
5.25
0.00
1.75
3.50
5.25
2.50
4.25
4.25
4.25
4.25
4.00
42.000
32.000
SAP
XCG
YCG
10.50
8.00
XCG
YCG
10.50
7.50
XCM
YCM
1.05
1.35
Excentricidad Accidental
Lx
Ly
ex
ey
21
17
1.05
0.85
"Eje x"
7m
7m
7m
13
14
15
16
10
11
12
7m
"Eje y"
Item
5m
5m
0.377
13.2
35
CLASIFIC.
FACTOR DE ZONA (Z)
3
FACTOR DE SUELO (S)
S1
FACTOR DE USO (U)
Comunes
FACTOR DE AMPLIFICACION SISMICA ( C )
COEFICIENTE DE REDUC. SISMICA ( R )
Prticos
TOTAL
VERIFICACION DE DERIVAS:
PISO
4
3
2
1
PISO
4
3
2
1
FUERZAS DE DISEO:
FUERZA
N max
V max
M max
seg
m
Prticos sin muros
FACTOR
0.35
1
1.00
2.50
8.00
0.125
P
Pi (Ton)
283.64
283.64
283.64
271.19
Hi
3.3
6.6
9.9
13.2
1,122.09
V=
C/R
Exponente "k"
Pi*Hi^k
936.00
1871.99
2807.99
3579.64
9,195.62
REGULAR:
IRREGULAR:
6
6.8
Dx (mm)
85.41
75.57
58.54
36.06
Deriva
0.003
0.005
0.007
0.011
Cumple
Ok
Ok
Ok
Reforzar
Dy (mm)
80.48
71.3
55.55
34.85
Deriva
0.003
0.005
0.006
0.011
Cumple
Ok
Ok
Ok
Reforzar
UND
ton
ton
ton.m
SISMO X
14.17
9.27
20.41
SISMO Y
20.39
9.98
20.97
Tp
0.4
Tl
2.5
Ia:
Ip:
1.00
1.00
122.73
0.31
1
alfa
0.10
0.20
0.31
0.39
Ton
OK!
Fi (Ton)
12.49
24.98
37.48
47.78
122.73
MIN
MAX
X (m) (a)=
Y (m) (b)=
3
3 por PISO
21.5
17.5
CALCULO DE MASAS:
TRASLACIONAL (T.s^2/m)
REGULAR
=
IRREGULAR
PISO
P (TON)
1
2
3
4
TOTAL
ROTACIONAL (T.s^2/m)
Ps (TON)
347.76
347.76
347.76
297.96
283.64
283.64
283.64
271.19
1,341.24
( +
12
)
)
MASA
MASA
TRASLACION ROTACIONAL
AL (Ts2/m)
(Ts2/m)
28.91
28.91
28.91
27.64
1851.63
1851.63
1851.63
1770.35
1122.09
=
FACTOR DE ZONA (Z)
FACTOR DE SUELO (S)
FACTOR DE USO (U)
GRAVEDAD (g)
COEFICIENTE DE REDUC. SISMICA ( R )
FACTOR DE ESCALA (FE)
CLASIFIC.
3
S1
Comunes
m/s^2
Prticos
FACTOR
0.35
1
1.00
9.81
8.00
0.42919
Tp
0.4
Tl
2.5
Ia:
1.00
Ip:
1.00
Load Case Data "Scale Factor"
RESPONSE SPECTRUM
T(seg)
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
2
2.1
2.2
2.3
2.4
2.5
2.6
2.7
2.8
2.9
3
3.5
4
4.5
5
5.5
6
6.5
7
7.5
8
8.5
9
9.5
10
C
2.50
2.50
2.50
2.50
2.50
2.00
1.67
1.43
1.25
1.11
1.00
0.91
0.83
0.77
0.71
0.67
0.63
0.59
0.56
0.53
0.50
0.48
0.45
0.43
0.42
0.40
0.37
0.34
0.32
0.30
0.28
0.20
0.16
0.12
0.10
0.08
0.07
0.06
0.05
0.04
0.04
0.03
0.03
0.03
0.03
Sa
1.07
1.07
1.07
1.07
1.07
0.86
0.72
0.61
0.54
0.48
0.43
0.39
0.36
0.33
0.31
0.29
0.27
0.25
0.24
0.23
0.21
0.20
0.20
0.19
0.18
0.17
0.16
0.15
0.14
0.13
0.12
0.09
0.07
0.05
0.04
0.04
0.03
0.03
0.02
0.02
0.02
0.01
0.01
0.01
0.01
REGULAR:
IRREGULAR:
6
6.8
VERIFICACION DE DERIVAS:
PISO
4
3
2
1
PISO
4
3
2
1
T (seg)
0.618
0.599
0.461
0.196
0.19
0.146
0.111
0.109
0.084
0.08
0.079
0.061
Dx (mm)
48.00
43.09
34.08
21.43
Deriva
0.001
0.003
0.004
0.006
Cumple
Ok
Ok
Ok
Ok
Dy (mm)
45.9
41.27
32.85
21.04
Deriva
0.001
0.003
0.004
0.006
Cumple
Ok
Ok
Ok
Ok
UND
ton
ton
ton.m
SISMO X
8.53
5.72
13.02
SISMO Y
11.83
6.36
14.07
COMPROBACIONES
REGULAR
< 0.8
IRREGULAR
Factor (0.8Ve/Vd)
1.26
FUERZAS DE DISEO (amplificado):
FUERZA
N max
V max
M max
FE
0.5388
UND
ton
ton
ton.m
< 0.9
SISMO X
10.71
7.18
16.35
0.8
0.9
SISMO Y
14.85
7.98
17.67