Presentacion Enchufes Tomas e Interruptores
Presentacion Enchufes Tomas e Interruptores
Tecnologa sobre Tableros Elctricos Protecciones: Tableros en material aislante, Interruptores. Termomagnticos, Interruptores Diferenciales. Complementos.
Interruptores
Tomacorrientes
MEDIDAS DE SEGURIDAD
Aislamiento adecuado de las partes en contacto con el usuario. Respetar las capacidades de corriente de cada dispositivo. Preferir adquirir aquellos dispositivos que cumplen con normas de seguridad y/o que tengan sellos de calidad.
Evitar: Cableados en el aire,con posibilidad de contacto ante el trnsito de personas. Empotramientos de conductores sin tubera conduit. Placas o dados rotos o colgando fuera del soporte. Conexin al tomacorriente utilizando cables sin enchufes.
g g
Implica: Preocuparnos por pedir al comerciante o fabricante los datos nominales del interruptor o tomacorriente. Descartar la idea de que si se le adaptan salidas mltiples a un tomacorriente aguantar mas amperaje que un tomacorriente simple. No conectarle a un interruptor todas las lmparas que se nos ocurran.
LNEAS SUPERFICIALES:
LNEAS EMPOTRABLES:
g
LNEAS MONOBLOCK: Los dados y placas en un solo bloque.Las combinaciones de dados vienen preestablecidas por el fabricante.
LNEAS MODULARES: Placas independientes de los dados. El usuario tiene libertad para elegir las combinaciones de dados en una placa, y puede escoger el tipo de placa. E
INSTALACIONES SUPERFICIALES
RECIEN SE PUEDE PRODUCIR UN ARCO ELECTRICO LUEGO DE 1 MINUTO DE APLICAR 2000 VOLTS
CUMPLIMIENTO NORMATIVO:RESISTENCIA DE
AISLAMIENTO
40000 MANIOBRAS A CORRIENTE Y TENSIN NOMINAL 200 MANIOBRAS CON EL 25% DE SOBRECORRIENTE Y 25% DE SOBRETENSIN
Esquemas funcionales
F N
Al apagar el foco el interruptor simple desconecta la nica fase viva. El neutro es el que est unido al foco y no hay ningn peligro para el usuario en el caso de querer cambiar el foco o hacer mantenimiento.
F1 F2
Al apagar el foco el interruptor simple solo desconecta una fase viva. La otra fase est unida al foco y hay peligro para el usuario en el caso de querer cambiar el foco o hacer mantenimiento.
INTERRUPTOR BIPOLAR
F1 F2
El interruptor bipolar desconecta simultaneamente las dos fases vivas.
CONCLUSION: El usuario puede hacer un mantenimiento seguro con solo desconectar la carga mediante el interruptor bipolar.
OPCIONES DE CONMUTACION
Interruptor de 3 vas Interruptor de 3 vas
Interruptor 3 vas
Interruptor 3 vas
L1
L2
IEC 60884-1:
Plugs and socket-outlets for household and similar purposes . Part 1: General requirements
CUMPLIMIENTO NORMATIVO:PRUEBA DE
FUNCIONAMIENTO PROLONGADO 10000 MANIOBRAS A CORRIENTE Y TENSIN NOMINAL 200 MANIOBRAS CON EL 25% DE SOBRECORRIENTE Y 25% DE SOBRETENSIN
TOMACORRIENTES DOMESTICOS:
Bipolares (2P)
Las carcazas de los equipos se conectan a un cable que deriva hacia el pozo de tierra. Las posibles corrientes de falla viajan por ese conductor
1 3 2 2
2 3
y 3
1 3 2
y 3
Obturadores
un cuerpo extrao no puede introducirse y una espiga sola no puede insertarse
proteccin alvolos
Enchufes reversibles
CONFIGURACIONES DE TOMACORRIENTES
Cul escogemos?
Situacin internacional
g g
IEC acepta todas las disposiciones constructivas usadas por los pases miembros. La tensin esta asociada a una forma de enchufe:
g g
Los tomacorrientes de espigas redondas son estndares predominantemente europeos y estn asociados a una tensin de 230V. El tomacorriente de espigas planas que solemos usar en nuestro medio es el standard americano.de acuerdo a NEMA 5-15R asociado a una tensin de 120V. El tipo de tomacorriente nos debera definir de por si el tipo de voltaje utilizado en ese punto. Asimismo un enchufe de espiga redonda debera indicarnos que el equipo es para un voltaje standard europeo,y un enchufe de espiga plana debera indicarnos que el equipo es para un voltaje standard americano. En nuestro pas usamos mayoritariamente el tomacorriente universal(2P), que acepta las espigas planas o redondas. Asimismo usamos indistintamente enchufes de espigas planas o redondas para los equipos o electrodomesticos. El tomacorriente universal no define especficamente un tipo de tensin (120V o 230V).Esto podra ocasionar algunos problemas.
El Tomacorriente Universal naci por la necesidad de utilizar un tomacorriente que se adapte a las distintas configuraciones de enchufes del mercado. En esencia es un adaptador ,pero no es conveniente considerarlo como de uso permanente. La IEC no lo menciona entre sus configuraciones porque el espritu es usar un tomacorriente que se adapte a un solo tipo de enchufe. Cuando convertimos al tomacorriente universal en un tomacorriente de uso permanente es evidente que a la larga el uso de distintos tipos de enchufe causen el deterioro y/o ensanchamiento de sus alveolos. El resultado final es contactos deficientes con alguno de los tipos de enchufe, con el consecuente riesgo para las instalaciones.
CONSIDERACIONES DE LA NORMA IEC 60884-1 PARA LOS ENCHUFES Y TOMACORRIENTES CUALES LOS CUMPLEN?
REGLAMENTO TECNICO ENCHUFES Y TOMACORRIENTES (CON PROTECCIN A TIERRA) PARA USO DOMSTICO Y USO GENERAL SIMILAR Articulo 1 OBJETO.El presente Reglamento Tcnico establece los requisitos tcnicos y de rotulado, que deben cumplir los enchufes y tomacorrientes fijos o portatiles para corriente alterna, con proteccin a tierra, bajo tensin nominal mayor a 50 V pero no superior a 440 V y una corriente nominal no mayor a 32 A, con el fin de que su utilizacin contribuya a la seguridad de las personas e instalaciones. La corriente nominal esta limitada a un mximo de 16 A, para tomacorrientes fijos con bornes sin tornillos. Articulo 2 CAMPO DE APLICACIN.El presente Reglamento Tcnico se aplica a los siguientes tipos de enchufes y tomacorrientes: 2.1.- Enchufes y tomacorrientes que se utilicen en instalaciones interiores y a la intemperie en viviendas unifamiliares, locales comerciales, edificios residenciales y pblicos. 2.2.- Enchufes acoplados a los extremos de cordones que sirven para la conexin de artefactos elctricos. 2.3.- Enchufes y tomacorrientes que son componentes de un artefacto. 2.4.- Enchufes y tomacorrientes acoplados a cordones que se emplean para la extensin de los circuitos a la tensin de utilizacin. El presente Reglamento Tcnico no se aplica a: Enchufes, tomacorrientes y adaptadores para propsito industrial. Artefactos adaptadores. Tomacorrientes fijos combinados con fusibles, interruptores automticos, o similares.
Acpites de cumplimiento
Tipo de tomacorriente
: : : 0.3 e ser n 0 .2 s 1 1 . 1 e b xi s 10 que n rt de one a o a Pa sible o o o c c h N le C rico eb un s ce ac lante as osib solo a ct e pru l p s i e d ai islad de esp g do a e d
6: e .5: tes .4: 10 rrien or 10. to d 10 tes e r co ad ta c Pa nas d en oma btur on ierra ble C t ma T no s ter r co ex hufe rial efo c d e n n t i e ma lante ais
ufe ch En
Redondo Italiano
X X
? ?
220V
Schuko
220V
X
Plano USA
110V
X
Universal 2P+T
10.1 Socket-outlets shall be so designed and constructed that when they are mounted and wired as for normal use, live parts are not accessible, even after removal of parts which can be removed without the use of a tool. Live parts of plugs shall not be accessible when the plug is in partial or complete engagement with a socket-outlet.
RETORNAR
10.5 Shuttered socket-outlets shall, in addition, be so constructed that live parts are not accessible without a plug in engagement, with the gauges shown in figures 9 and 10. The gauges shall be applied to the entry holes corresponding to the live contacts only and shall not touch live parts. To ensure this degree of protection, socket-outlets shall be so constructed that live contacts are automatically screened when the plug is withdrawn.
RETORNAR
RETORNAR
10.3 It shall not be possible to make contact between a pin of a plug and a live socket contact of a socket-outlet while any other pin is accessible.
Configuraciones de voltaje
RETORNAR
RETORNAR
10.6 Earthing contacts, if any, of a socket-outlet shall be so designed that they cannot be deformed by the insertion of a plug, to such an extent that safety is impaired.
REGLAMENTO TECNICO:CONFIGURACIONES PROPUESTAS Configuraciones para Enchufes y Tomacorrientes 2P+T de acuerdo al Reglamento Tcnico
Grado de proteccin IP40: La caja impide la entrada de objetos de dimetro superior a 1 mm.
Grado de proteccin IP55: La caja protege a los dados del polvo ,sin sedimientos perjudiciales y del lanzamiento de agua en cualquier direccin.
Tecnologa sobre Tableros Elctricos Protecciones: Tableros en material aislante, Interruptores. Termomagnticos, Interruptores Diferenciales. Complementos.
Interruptores termomagnticos
Interruptores diferenciales
Los interruptores termomagnticos bajo norma europea (como los Btdin) estn diseados para trabajar nominalmente hasta 400V entre fases. En nuestro pas existen ciudades que tienen el sistema 380/220V. En los circuitos y cargas trifsicas en este tipo de ciudades es imprescindible que los interruptores de proteccin puedan trabajar con una tensin de 380V entre fases. Tener en cuenta que los interruptores de proteccin bajo norma americana estn diseados para un voltaje mximo entre fases de 240V
Normal
Funcionamiento
los parmetros se encuentran dentro de los mrgenes preestablecidos
Anormal
uno o ms parmetros se encuentran sobre o bajo los valores preestablecidos
Perturbacin
Funcionamiento Anormal
anormalidad de breve duracin, que no constituye riesgo para la instalacin o las personas
Falla
Fallas: sobrecargas cortocircuitos fallas de aislamiento
anormalidad grave, que constituye riesgo para la instalacin o las personas
Proteccin contra:
Cortocircuitos
Sobrecargas
EL INTERRUPTOR TERMOMAGNETICO
*MEJOR RESPUESTA EN SOBRECARGAS *MUCHO MEJOR RESPUESTA EN CORTOCIRCUITOS *EL USUARIO NO TIENE QUE DESARMAR PARA REEMPLAZO DE FUSIBLES EN EL CASO DE OPERACIN POR SOBRECARGA O CORTOCIRCUITO
Interruptor de proteccin
Interruptor termomagntico
: Interruptor termomagntico
Bimetal de deteccin trmica (sobrecarga)
Portadgito
Bobina de deteccin magntica (cortocircuito) Embolo mvil del circuito magntico Cmara de corte
Cmara de arqueo de hierro cobreado altamente oxidable y revestimiento de cartn. Poco confiable ante el arco elctrico
Tornillo de calibracin sellado para garantizar curva de operacin Tornillos con mejor revestimiento anticorrosivo Bornes de acero con revestimiento anticorrosivo y tropicalizado
Tornillos con pobre tratamiento anticorrosivo Contactos sin bao de plata.Peores condiciones de continuidad.
IN1
Intensidad mxima admisible por el conductor = IZ Corriente de carga mxima = IB Corriente nominal de la proteccin = IN
IN2
IN3
IN4
Carga
IB
<
IN
IZ
ICN1
ICN2
ICN3
ICN4
ICC
ICN
ICC
R S T
R S
T R
S T
ALIMENTACION
R S T
Indirecto
I1
I2
ESTA FUGA PUEDE DEBERSE A: CONTACTO ELECTRICO DIRECTO DE UNA PERSONA A UNA LINEA VIVA (POSIBLE ELECTROCUCION) b) CONTACTO DE UN CABLE MAL AISLADO A UNA PARTE CONDUCTORA COMO CARCAZAS METALICAS LO QUE PUEDE CAUSAR RECALENTAMIENTOS Y/O EXCESOS DE CONSUMO a)
If
La fuga se deriva hacia tierra protegiendo al usuario,y el diferencial la detecta abriendo el circuito,evitando riesgos de recalentamiento e incendios por fallas de aislamiento
En el caso de falla de la puesta a tierra por mal mantenimiento o mal contacto el diferencial es clave para continuar con la proteccin de las personas
CONTACTO DIRECTO
Aunque hubiera puesta a tierra en la instalacin,esta no protege contra los contactos directos.!!
Proteccin contra un contacto directo solo puede ser posible mediante el interruptor diferencial.!!
circuito 1
circuito 2
circuito 3
interruptores diferenciales
CONCLUSION
No olvidar que:
El interruptor termomagntico protege al conductor de la instalacin de sobrecargas y cortocircuitos
El interruptor diferencial protege a las personas de posibles electrocuciones y protege a la instalacin de daos causados por fugas de corriente
Son complementarios
NINGUNO REEMPLAZA AL OTRO !!
Clases de proteccin
Contra cuerpos slidos I.P. Contra los lquidos I.P.
0 1 2 3 4 5 6
Sin proteccin Protegido contra cuerpos slidos superiores a 50 mm Protegido contra cuerpos slidos superiores a 12,5 mm Protegido contra cuerpos slidos superiores a 2,5 mm Protegido contra cuerpos slidos superiores a 1 mm Protegido contra el polvo Totalmente protegido contra el polvo
0 1 2 3 4 5 6 7 8
Sin proteccin Protegido contra cadas verticales de gotas agua Protegido contra cadas de agua hasta 15 de la vertical Protegido contra agua de lluvia hasta 60 de la vertical Protegido contra proyecciones de agua en todas las direcciones Protegido contra lanzamiento de agua en todas las direcciones Protegido contra lanzamiento de agua similar a golpes de mar Protegido contra la inmersin Protegido contra efectos prolongados de inmersin bajo presin
Esta norma se refiere a las caractersticas que deben cumplir los tableros y sus componentes internos cuando la instalacin se realiza en lugares donde el usuario no es personal necesariamente adiestrado(Ej: instalaciones domsticas)
MINITABLEROS (CALOTAS)
g
g g g g g g
MODELO IP40
De 2,4 y 6 polos. De sobreponer. Grado de proteccin IP 40. Resina termoplstica autoextinguible. Elevada resistencia a los rayos ultravioletA Conforme a normas IEC 60439-3.
g g g g
Grado de proteccin IP 40 (con puerta). Resistencia a los rayos UV y prueba de hilo incandescente hasta 650C. Estabilidad trmica entre -25C y 85C. Color blanco. Conforme a norma IEC 439-3. Desde 6 polos hasta 36 polos
+
falsos polos
ACCESORIO OPCIONAL Nota: Caja y frente en un solo cdigo en el de 36 polos Borneras de 8 derivados para fijacin directa a caja
Lnea Residencial
Casas
Residencias
g g g
g g
Grado de proteccin IP 55 (con puerta). Resistencia a los rayos UV y prueba de hilo incandescente hasta 850C. Color gris. Estabilidad trmica entre -20C y 70C. Los tableros IP55 son especialmente apropiados para instalacin de tableros a la intemperie y condiciones ambientales agresivas. Conforme a norma IEC 439-3. Desde 4 polos hasta 54 polos
Lnea Idroboard
Fijacin a pared
Kit de acoplamiento
Lnea Idroboard
Diseados para ser utilizados en cualquier sector:
Domstico
Comercial/Servicios
Industrial
fernando.vargascano@bticino.com www.bticino.com.pe