PASOLINK NETWORK MANAGEMENT TERMINAL (PNMT) IS A MOBILE TERMINAL CONSISTING OF A PORTABLE COMPUTER WITH A SIMPLIFIED VERSION OF THE PASOLINK NETWORK MANAGEMENT SOFTWARE DEVELOPED FOR MANAGEMENT OF NEC PASOLINK SERIES SHORT HAUL RADIO TRANSMISSION NETWORK. PNMT IS DESIGNED AS AN ONSITE MAINTENANCE TOOL TO BE USED BY THE FIELD ENGINEERS AND TECHNICIANS. IT CONNECTS DIRECTLY TO THE PNMT PORT OF THE PASOLINK IDU. PNMT CAN BE USED TO MONITOR LOCAL / REMOTE EQUIPMENT STATUS AND PROVIDES CONTROL CAPABILITIES SIMILAR TO THOSE AVAILABLE IN PNMS. PNMT IS ALSO USED TO DOWN LOAD SYSTEM AND CONFIGURATION FILES TO THE NE AND UPGRADE THE SOFTWARE IN THE IDU WHEN CONNECTED TO AN IDU PNMT CAN MONITOR NOT ONLY THE LOCAL EQUIPMENT BUT ANY REMOTE NETWORK ELEMENT UNDER THE CONTROL OF THE CENTRAL PM.
PNMT
FUNCTIONS
MICROSOFT WINDOWS 98/NT/2000/XP WORKSTATION GRAPHICAL USER INTERFACE ONE HOP LINK DISPLAY ON THE PNMT SCREEN COMMUNICATE WITH REMOTE NEs ON THE SAME NETWORK COLLECTS ALARM AND STATUS INFORMATION FROM THE LOCAL AND REMOTE NEs TRANSMISSION EQUIPMENT CONTROL VIA LOCAL AND REMOTE CTRL MODULES SEVERAL LEVELS OF LOGIN / LOGOUT EVENT LOGGING WINDOW PERFORMANCE MONITORING FUNCTION WINDOW LOCAL / REMOTE EQUIPMENT CONTROL FUNCTION LOCAL/REMOTE PM CONFIGURATION MANAGEMENT LOCAL/REMOTE UP GRADING OF APPLICATION SOFTWARE
PNMT
PNMT PORT
PNMT
HARDWARE/SOFTWARE CONFIGURATION
RECOMMENDED PNMT MOBILE PC CONFIGURATION LAPTOP PC WITH TFT DISPLAY (IBM COMPATIBLE) CPU: PENTIUM-II 500 MHz OR HIGHER RAM: 128 MB OR MORE HDD: 5 GB OR MORE FDD: 3.5INCH CD-ROM: 8 x OR HIGHER INTEGRATED SOUND CARD AND SPEAKER
SOFTWARE CONFIGURATION ALL STRUCTURED AND MODULAR PROGRAMS USED IN PNMT ARE RESIDENT IN THE HARD DISK AND RAM OF THE PERSONAL COMPUTER. THE WINDOWS OPERATING SYSTEM IS EMPLOYED WHICH IS CAPABLE OF MULTITASK PROCESSING. THE PNMT SOFTWARE BASICALLY CONSISTS OF TWO PARTS, THE OPERATING SYSTEM AND THE APPLICATION PROGRAM OPERATING SYSTEM WINDOWS 98 (ENGLISH VERSION) OR WINDOWS NT WORKSTATION Ver 4.0 (ENGLISH VERSION) WINDOWS 2000 (ENGLISH VERSION) WINDOWS XP (ENGLISH VERSION) APPLICATION PROGRAM NEC PNMT SOFTWARE
PNMT
START UP
CONNECT THE PNMT PC COM1 PORT AND THE PASOLINK IDU PNMT PORT USING A RS232C CABLE DOUBLE CLICK ON THE PNMT SHORTCUT ICON ON THE DESKTOP OR CLICK ON START>>PROGRAM>>PNMT>>PNMT
PNMT PROGRAM STARTUP AND TRIES TO GET CONNECTED TO THE PASOLINK EQUIPMENT
AFTER CONNECTING TO THE PASOLINK EQUIPMENT TRIES TO ACQUIRE DATA FROM THE LOCAL EQUIPMENT AND THE REMOTE EQUIPMENT TO DISPLAY ON THE LINK SUMMARY WINDOW
PNMT
SHUT DOWN
IF YOU HAVE NOT LOGIN FIRST THE EXIT MENU CANNOT BE SELECTED.
TO EXIT THE PNMT PROGRAM CLICK ON EXIT IN THE SYSTEM DROPDOWN MENU AND CLICK YES.
THE SCREEN INDICATES NOW PNMT SHUTDOWN. IT WILL TAKE FEW MINUTES TO SHUTDOWN
PNMT
BLOCK DIAGRAM
NE-SPECIFIC DATA
CLICK ON THE ARROW ICONS IN THE MIDDLE OF THE SCREEN TO EXPAND THE LEFT OR RIGHT DATA WINDOW. CLICKING ON THE BLOCK WILL RETURN THE ORIGINAL SPLIT SCREEN.
SELECTED NE
OPPOSITE NE
LOGIN INFORMATION
PNMT
LINK SUMMARY WINDOW LINK SUMMARY WINDOW SHOWS THE SELECTED NETWORK ELEMENT (NE) AND ITS OPPOSITE NE AS A LINK (HOP). THE SELECTED NE IS SHOWN ON THE LEFT HAND SIDE WINDOW AND THE OPPOSITE NE ON THE RIGHT HAND SIDE WINDOW OF THE LINK SUMMARY WINDOW. IT SHOWS GRAPHICALLY THE STATUS OF THE PASOLINK EQUIPMENT IN BLOCK DIAGRAM FORM. NE-SPECIFIC PARAMETERS AND NE-SPECIFIC MENU ITEMS ARE ALSO SHOWN IN THIS WINDOW NE SPECIFIC DATA : NE SPECIFIC DATA ARE SHOWN IN SEVERAL DATA WINDOWS SELECTED BY THE TABS AT THE BOTTOM OF THE WINDOW OR BY CLICKING THE EQUIPMENT SYMBOLS IN THE BLOCK DIAGRAM. NE SPECIFIC MENU ITEMS: EQUIPMENT CONFIGURATION EVENT LOG LINK PERFORMANCE MONITOR TAB SELECTION DETAILED MONITORING STATUS AND ALARMS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P CTRL AND VERSION) CAN BE VIEWED BY CLICKING ON THE RELEVANT TAB. EQUIPMENT SETUP PROVISIONING MAINTENANCE
NE BLOCK DIAGRAM: STATUS OF EACH MAIN UNIT IN THE PASOLINK EQUIPMENT (ODU, IDU, AUX I/P AND CTRL) ARE SHOWN IN THE BLOCK DIAGRAM AS SYMBOLS. WHEN ANY SYMBOL IS CLICKED THE RELATED EQUIPMENT WINDOW OPEN AND SHOWS THE DETAILS OF ALARM AND STATUS DETAILS AND OTHER PARAMETERS,
PNMT
SYSTEM
REFRESH
HELP DISPLAY A LIST OF PNMT MANUALS IN PDF FILE FORMAT DISPLAY THE PNMT VERSION NUMBER THIS FUNCTION ENABLES PNMT TO ACQUIRE ALL STATUS MANUALLY AND TO UPDATE EQUIPMENT INFORMATION THIS FUNCTION OPEN THE LOGIN/LOGOUT WINDOW TO ENTER THE USER NAME AND PASSWORD.
HELP ABOUT
THIS FUNCTION OPEN THE PASSWORD CHANGE WINDOW THIS FUNCTION IS USED TO ENABLE/DISABLE THE BUZZER FUNCTION AND DEFINE THE BUZZER SOUND THIS FUNCTION IS USED TO DISPLAY THE SUMMARY LIST OF THE NETWORK ELEMENTS IN THE NETWORK
PNMT
THIS FUNCTION DOWN LOAD THE PERFORMANCE DATA FROM THE SELECTED NE AND OPEN THE G826 LINK PERFORMANCE INFORMATION WINDOW.
THIS FUNCTION UPLOAD THE EVENT LOG INFORMATION FROM THE SELECTED NE AND DISPLAY THE INFORMATION IN EVENT LOG WINDOW FREQUENCY SETTING EQUIPMENT SETUP PROVISIONING MAINTENANCE MTPC / ATPC MODE FRAME ID MAIN INTFC ELCT/OPT REDUNDANCY SELECT ALS DELAY TIME MAINT MODE ON/OFF NEAR END LOOPBACK FAR END LOOPBACK IF LOOPBACK SWITCHOVER (1+1) TX MUTE ON/OFF CW ON/OFF ALS RESTART ATPC MANUAL OH ASSIGNMENT MTPC STATUS ATPC STATUS SUB BB INTERFACE BER THRESHOLD
PNMT
10
CLICK ON SYSTEM IN THE MENU BAR AND THEN CLICK ON LOGIN/LOGOUT IN THE DROP DOWN MENU TO OPEN THE LOGIN/LOGOUT WINDOW TO LOGIN SELECT LOGIN IN THE LOGIN/LOGOUT WINDOW. ENTER THE USER NAME ACCORDING TO THE PRIVILEGES AND THE PASSWORD. CLICK OK TO LOGIN TO PROTECT THE NETWORK AND NETWORK MANAGEMENT SYSTEM FROM UNAUTHORIZED ACCESS OR MODIFICATIONS, FIVE LEVELS OF USERS ARE DEFINED WITH DIFFERENT PRIVILEGES. THE FUNCTIONS AVAILABLE DEPENDS ON THE USER ACCESS LEVEL, (SEE THE TABLE NEXT PAGE)
PNMT
11
RX THRESHOLD LEVEL
RX THRESHOLD LEVEL
ADDITIONAL ATT
BER THRESHOLD
RX SWITCH (RADIO)
SD ( MUX / DMR)
MAIN INTERFACE
PNMT
12
OVERALL WINDOW
OVERALL WINDOW FOR (1+0) CONFIGURATION OVERALL WINDOW FOR (1+1) CONFIGURATION
MTPC MODE
ATPC MODE
OVERALL WINDOW DISPLAY THE FOLLOWING INFORMATION: WHEN MTPC MODE IS SELECTED, MTPC POWER LEVEL TX AND RX FREQUENCIES USED FRAME ID USED TX POWER CONTROL MODE SELECTED (ATPC OR MTPC) MAIN INTERFACE USED (ELECTRICAL OR OPTICAL) ALS FUNCTION ENABLE / DISABLE STATUS MAINTENANCE MODE ON OR OFF STATUS. IF ON, BACK GROUND COLOR CHANGE TO YELLOW. SELECTED TX AND RX CHANNEL IN (1+1) CONFIGURATION CLICK THE OVERALL TAB TO DISPLAY THE OVERALL WINDOW
PNMT
13
ODU WINDOW
CLICK THE ODU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS ODU WINDOW FOR (1+1) CONFIGURATION
CLICK THE ODU TAB TO OPEN THE ODU WINDOW TO VIEW THE ODU DETAILS
PNMT
14
ODU DETAIL
IN (1+1) CONFIGURATION, ONLINE SELECTED/NOT SELECTED STATUS GREEN SELECTED WHITE NOT SELECTED TX INPUT ALM TX POWER ALM STATUS AND MONITORING TX POWER METERING MTPC TX POWER RX THRESHOLD LEVEL TRANSMITTED POWER OF THE ODU IN dBm LOSS OF TX IF INPUT LEVEL IN THE ODU TX RF POWER DECREASES 3 TO 6 dB FROM NOMINAL
INDICATES THE ATTENUATION VALUE USED IN MTPC MODE INDICATES THE RX LEVEL AT WHICH ATPC IS ACTIVATED
ADDITIONAL ATTENUATION INDICATES THE AMOUNT OF ADDITIONAL ATTENUATION USED ATPC CONTROL RANGE ODU ALARM MODE MAX AND MIN POWER LEVELS FOR ATPC MODE WHEN CONTROL BETWEEN IDU AND ODU FAIL THE ODU OUTPUT POWER SETTING
ODU RECEIVE LEVEL FALLS BELOW SQUELCH LEVEL ODU RF RX LEVEL IN dBM
INDICATES THE ODU LOCAL OSCILLATOR UNLOCK CONDITION INDICATES THAT COMMUNICATION BETWEEN ODU AND IDU FAILS
POWER SUPPLY METERING DISPLAY THE VALUE OF ODU POWER SUPPLY LEVEL IN VOLTS
PNMT
15
IDU WINDOW
CLICK THE IDU SYMBOL IN THE BLOCK DIAGRAM TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS IDU WINDOW FOR (1+0) CONFIGURATION IDU WINDOW FOR (1+1) CONFIGURATION
CLICK THE IDU TAB TO OPEN THE IDU WINDOW TO VIEW THE IDU DETAILS
PNMT
16
IDU DETAIL
MAIN INTFC ALM 150MB INTFC / OPT INTFC FAILURE SUB INTFC ALM WS INTFC / LAN CARD FAILURE ( OPTION) MODEM ALM 1-2 MODEM 1 OR MODEM 2 FAILURE PS ALM 1-2 IDU1 OR IDU 2 POWER SUPPLY FAILURE
IN (1+1) CONFIGURATION, ON LINE SELECTED/NOT SELECTED STATUS GREEN SELECTED WHITE NOT SELECTED MOD ALM MODULATOR FAILURE DUE TO TX SIDE LSI FAILURE DEM ALM DEMODULATOR FAILURE DUE TO RX SIDE LSI FAILURE HIGH BER ALM IN THE 1+1 CONFIGURATION HIGH BER ALM ON THE RADIO SECTION
IDU COMMON ALARMS MAIN INTFC LOS LOSS OF STM-1 INPUT SIGNAL SUB INTFC LOS WS INTFC OR LAN CARD INPUT SIGNAL FAILURE MDCPU INDICATES COMMUNICATION FAILURE BETWEEN CPU AND OTHER MODULES LOF MUX STM-1 SIGNAL SYNCHRONIZATION FAILURE FROM THE MUX SIDE LOF DMR STM-1 SIGNAL SYNCHRONIZATION FAILURE FROM THE RADIO SIDE E-BER MUX EXCESSIVE BER ALARM FROM THE MUX SIDE E-BER DMR EXCESSIVE BER ALARM FROM THE RADIO SIDE SIGNAL DEGRADE MUX SD ALARM OF THE ATM-1 SIGNAL FROM MUX SIDE STATUS COLORS GREEN NORMAL RED ALARM SIGNAL DEGRADE DMR SD ALARM OF THE STM-1 SIGNAL FROM RADIO SIDE
PNMT
17
IDU DETAIL
MAIN INTERFACE STM-1 ALS WHEN OPTICAL INTERFACE IS USED, ALS FUNCTION ENABLE /DISABLE STATUS ALS DELAY TIME WHEN ALS IS OPERATING DELAY TIME BETWEEN 2SEC LASER TRANSMISSIONS STM-1 OUTPUT CONTROL STM-1 O/P MS AIS IS INSERTED INDICATE NORMAL UNDER EXECUTION WHEN UNFRAMED ALL1 ARE INSERTED MAIN INTERFACE 10/100 BASE-T LINK WHEN LAN PORT CONNECTION TO EXTERNAL EQUIPMENT IS DISCONNECTED COLLISION MODE INDICATE ALARM OTHERWISE NORMAL WHEN LAN PORT COLLISION STATUS NORMAL OR COLLISION LAN PORT MODE IS 10BASE-T OR 100 BASE-T
DUPLEX LAN PORT DUPLEX MODE USED IS FULL DUPLEX OR HALF DUPLEX LINK DOWN CONTROL FAR END LINK DOWN CONTROL STATUS NORMAL / UNDER EXECUTION SUB - INTERFACE SUB INTERFACE TYPE OF SUB INTFC USED (WS/LAN) OR NOT USED STATUS WS INTFC TYPE OF WS CARD USED, 2MB OR 1.5 MB INVALID WHEN WS INTFC IS NOT USED WS LINE LENGTH WHEN THE WS INTFC CARD USED IS 1.5MB TYPE, LINE LENGTH SETTING AIS RCVD AIS SEND OH ASSIGNMENT ASSIGNMENT OH ASSIGNMENT SELECTED : CUSTOMIZE OR EASY ASSIGNMENTS FOR EACH OH CHANNEL IN THE WS INTFC CARD AIS SIGNAL IS RECEIVED OR NOT STATUS IN THE WS INTFC CARD AIS IS SENT OR NOT STATUS
BER METERING SIGNAL DEGRADE (MUX) E-BER (MUX) SIGNAL DEGRADE (DMR) E-BER (DMR) HIGH BER RX SWITCH
CURRENT VALUE OF THE DETECTED BER THRESHOLD SETTING FOR SIGNAL DEGRADE BER FOR MUX SIDE EXCESSIVE BER THRESHOLD SETTING FOR MUX SIDE THRESHOLD SETTING FOR SIGNAL DEGRADE BER FOR RADIO SIDE EXCESSIVE BER THRESHOLD SETTING FOR RADIO SIDE THRESHOLD SETTING FOR HIGH BER ALARM ( FOR 1+1 SYSTEMS) BER THRESHOLD SETTING FOR REDUNDANCY SWITCHING (FOR 1+1 SYSTEMS)
PNMT
18
CHANGE PASSWORD
CLICK ON CHANGE PASSWORD IN THE SYSTEM DROPDOWN MENU TO OPEN THE CHANGE PASS WORD WINDOW.
CLICK OK TO CHANGE THE PASSWORD. CLICK CANCEL TO EXIT WITHOUT CHANGING PASSWORD
PNMT
19
ALARM BUZZER
CLICK ON ALARM BUZZER ON THE SYSTEM DROP DOWN MENU TO OPEN THE ALARM BUZZER SETTING WINDOW. SELECT NO SOUND TO DISABLE THE BUZZER
SELECT WAVE FILE TO ENABLE THE BUZZER. THE BUZZER SOUND CAN BE CHANGED BY SELECTING A DIFFERENT WAV FILE. USE BROWSE TO LOCATE THE PATH TO THE WAV FILE. CLICK HERE TO TEST THE BUZZER SOUND
CLICK OK TO IMPLEMENT THE OPTION SELECTED OR CLICK CANCEL TO EXIT WITHOUT CHANGING THE SETTINGS.
SELECT BEEP TO ENABLE THE BUZZER WITH BEEP FREQUENCIES INSTEAD OF WAVE FILE SOUND BEEP FREQUENCY CAN BE DEFINED BY CLICKING ON EDIT AND SELECTING THE FREQUENCIES AND DURATION FOR EACH FREQUENCY. CLICK THE ARROW KEY TO ADD TO THE LIST. SEVERAL FREQUENCIES CAN BE ADDED TO THE BEEP SIGNAL. SELECTED FREQUENCIES CAN BE DELETED BY SELECTING THE FREQUENCY FROM THE LIST AND CLICKING ON THE DELETE SYMBOL.
PNMT
20
CLICK CONNECT ON THE SYSTEM DROP DOWN MENU TO LIST THE LOCAL NEs THE PNMT IS CONNECTED TO.
LIST MENU
CLICK THE SEARCH FOR NETWORK ELEMENT TO SEARCH AND LIST THE OTHER NEs IN THE NETWORK
TO VIEW A REMOTE NE FROM THE NETWORK ELEMENT LIST, SELECT AND HIGHLIGHT THE NE IN THE LIST. THEN CLICK THE CONNECT TO NETWORK ELEMENT FROM THE LIST DROP DOWN MENU. SELECT YES FROM THE DIALOG BOX. THE SELECTED NE AND ITS OPPOSITE NE WILL BE DISPLAYED IN THE LINK SUMMARY WINDOW. TOOL BAR ITEMS
PNMT
21
HELP FUNCTION
PNMT HELP FUNCTION IS AVAILABLE AS PNMT MANUAL IN PDF FILE FORMAT. IF THE ACROBAT READER IS INSTALLED IN THE PNMT PC, CLICKING HELP AND SELECTING THE RELEVANT PNMT FILE WILL OPEN THE PDF FILE TO PROVIDE HELP FUNCTION TO THE USER.
BUZZER STOP ICON IS ACTIVE ONLY WHEN THE ALARMED EQUIPMENT DISPLAY WINDOW IS SELECTED FROM THE TABs OR FROM THE BLOCK DIAGRAM SYMBOLS. REFRESH - OPEN THE NE LIST WINDOW CONNECT - OPEN THE NE LIST WINDOW OPEN THE LOGIN/LOGOUT WINDOW
PNMT
22
IN 1+1 HOT STBY, ODU1 IS ONLY SHOWN AS ODU2 HAS THE SAME SETTING INDICATES THE ODU FREQUENCY BAND INFORMATION AND TX/RX FREQUENCIES IN 1+1 TWIN PATH BOTH ODU1 AND ODU2 ARE SHOWN, AS THE SETTINGS ARE INDEPENDENT
IN 1+1 HOT STBY, FRAME ID FOR NO.1 AND NO.2 ARE THE SAME IN 1+1 TWIN PATH FRAME ID CAN BE SET THE SAME OR DIFFERENT
SHOW THE FRAME ID SETTING SETUP BUTTON OPEN THE SETUP CONTROL WINDOW NE NAME IS DISPLAYED. CAN BE CHANGED FROM HERE NOTE ENTERED FOR THE SELECTED NE IS DISPLAYED. CAN BE CHANGED FROM HERE IN THE CASE OF 1+0 ONLY ONE ODU AND IDU SETTINGS ARE DISPLAYED
PNMT
23
CONTROL SETTING
FROM THE EQUIPMENT SETUP WINDOW CLICK THE NE NAME BUTTON TO OPEN THE NE NAME SETTING WINDOW.
THE NAME ENTERED TO IDENTIFY THE NETWORK ELEMENT CAN BE CHANGED FORM THIS WINDOW. A MAXIMUM OF 32 CHARACTERS CAN BE USED.
ENTER THE NAME AND CLICK EXECUTE TO SHOW THE NAME IN THE EQUIPMENT SETUP WINDOW. CLICK THE NOTE BUTTON TO OPEN THE NOTE WINDOW.
A NOTE DESCRIBING THE NETWORK ELEMENT CAN BE ENTERED FROM THIS WINDOW. UP TO 80 CHARACTERS CAN BE USED IN THIS FIELD ENTER THE NOTE AND CLICK EXECUTE TO SHOW THE NOTE IN THE EQUIPMENT SETUP WINDOW.
PNMT
24
ENTER OR SELECT THE TX FREQUENCY ACCORDING TO THE FREQUENCY TABLES. CORRESPONDING RX FREQUENCY IS AUTOMATICALLY DISPLAYED SELECT THE TX POWER CONTROL MODE ATPC OR MTPC REDUNDANCY CONFIGURATION SELECTION AUTOMATICALLY INDICATES THE SDH SIGNAL TYPE MAIN INTFC SELECTION AUTOMATICALLY INDICATE THE MODULATION TYPE FRAME ID SETTING (0-7). IN THE CASE OF HOT STANDBY BOTH N0.1 AND NO.2 CHANNEL HAVE THE SAME SETTING. IN THE CASE OF TWIN PATH FRAME ID FOR NO.1 AND NO2 CHANNELS CAN BE SET SEPARATELY.. CLICK THE EXECUTE BUTTON TO CARRY OUT THE EQUIPMENT SETUP SETTINGS. CLICK THE CLOSE BUTTON TO EXIT THE SETUP CONTROL WINDOW
10/100BASE-T
PNMT
25
FREQUENCY CONTROL
ODU FREQUENCY BAND INFORMATION ARE DISPLAYED HERE. CHANGE THE TX FREQUENCY AND THE CORRESPONDING RX FREQUENCY IS DISPLAYED
WHEN SETTING THE FREQUENCY FOLLOWING SHOULD BE CONSIDERED FOR THE 6/7/8 GHZ BAND ODUs THE TRANSMIT FREQUENCY MUST BE THE SAME AS THAT INDICATED ON THE LABEL ATTACHED ON THE SIDE OF THE ODU. IF ANOTHER FREQUENCY IS SET, NORMAL TRANSMISSION AND RECEPTION OF THE RF SIGNAL IS NOT POSSIBLE. FOR THE 11-38 GHZ BAND ODUs, THE FREQUENCY SET SHOULD BE WITHIN THE TRANSMIT FREQUENCY BAND OF THE ODU. (REFER TO THE DOCUMENT RADIO FREQUENCY PLAN FOR THE PASOLINK+). FOR THE 11-38GHZ BAND ODUs USED IN 32 QAM SYSTEMS, THE FREQUENCY SETTING SHOULD BE AT LEAST +21 MHZ AWAY FROM THE BANDS START FREQUENCY AND AT LEAST -21 MHZ AWAY FROM THE BANDS STOP FREQUENCY. FOR THE 11-38GHZ BAND ODUs USED IN 128 QAM SYSTEMS, THE FREQUENCY SETTING SHOULD BE AT LEAST +12 MHZ AWAY FROM THE BANDS START FREQUENCY AND AT LEAST -12 MHZ AWAY FROM THE BANDS STOP FREQUENCY. IN (1+1) HOT-STANDBY SYSTEMS, THE FREQUENCY ENTERED IS AUTOMATICALLY SET FOR BOTH NO.1 AND NO.2 ODUs IN (1+1) TWIN PATH SYSTEMS, THE FREQUENCY SETTING OF THE NO.1 AND NO.2 ODUs ARE NOT IDENTICAL AND ARE ENTERED SEPARATELY.
PNMT
26
PROVISIONING
CLICK CONFIGURATION ON THE NE SPECIFIC MENU AND SELECT PROVISIONING TO OPEN THE PROVISIONING WINDOW.
SUB INTERFACE SETTING ALS ENABLE AND ALS DELAY SETTING INDICATE THE LAN PORT SETTINGS BER THRESHOLD SETTING
INDICATE THE TX POWER CONTROL MODE WHEN MTPC MODE IS SELECTED MTPC POWER SETTING WHEN ATPC MODE IS SELECTED ATPC POWER SETTING
EITHER MTPC SETTING OR ATPC SETTING WINDOWS WILL BE DISPLAYED AT A TIME, DEPENDING ON THE TX POWER CONTROL MODE SELECTED.
PNMT
27
ALS SETTING
ALS CLICK ALS BUTTON IN THE PROVISIONING WINDOW TO OPEN ALS SETTING WINDOW.. THIS FUNCTION IS AVAILABLE FOR OPTICAL INTERFACE ONLY.
TO ENABLE ALS FUNCTION SELECT ENABLE OR SELECT DISABLE TO DISABLE IT, CLICK EXECUTE TO CARRY OUT THE SELECTION. CLICK CLOSE TO EXIT ALS SETTING WINDOW.
ALS DELAY TIME CLICK ALS DELAY TIME BUTTON IN THE PROVISIONING WINDOW TO OPEN ALS DELAY TIME SETTING WINDOW.. THIS FUNCTION IS AVAILABLE FOR OPTICAL INTERFACE ONLY. SELECT THE DELAY TIME FOR ALS OPERATION AND CLICK EXECUTE. CLICK CLOSE TO EXIT THE ALS DELAY TIME SETTING WINDOW. AUTOMATIC LASER SHUT DOWN FUNCTION WHEN THE OPTICAL SIGNAL INPUT TO THE MAIN INTFC IS LOST, THE ALS FUNCTION AUTOMATICALLY SHUTS THE MAIN INTFC OUTPUT LASER. MAIN INTFC WILL THEN PERIODICALLY TRANSMIT A 2MSEC BURST OF LASER. THE ALS DELAY TIME DEFINES THE DURATION BETWEEN 2SEC BURSTS OF LASER EMISSION. THE DELAY TIME CAN BE SET TO 60, 180 OR 300 SECONDS.
PNMT
28
OH ASSIGNMENT
CLICK ASSIGNMENT BUTTON TO OPEN THE OH ASSIGNMENT SETTING WINDOW.
MUX PASOLINK+ E1 (DMR) F1 (DMR) DSC1 TO 4 PASOLINK+ MUX
THERE ARE TWO VOICE CHANNELS , TWO V11 CHANNELS AND OPTIONAL LAN PORT AVAILABLE IN PASOLINK PLUS EQUIPMENT. IT IS POSSIBLE TO ASSIGN THESE CHANNELS TO ANY OF THE EIGHT SDH OH AND RADIO OH CHANNELS AS SHOWN IN THE DIAGRAM. THE ASSIGNMENT OF THESE CHANNELS CAN BE CUSTOMIZE BY THE USER OR USE THE FACTORY DEFAULT.... PROVISIONING WINDOW
E1 (MUX) F1 (MUX)
E1 (MUX) F1 (MUX)
EASY WHEN EASY IS SELECTED THE SAME SETTING AS THE FACTORY SETTING IS USED. WITH THIS SELECTION, LAN CARD ASSIGNMENT IS NOT POSSIBLE. V11 DIRECTION SETTING CAN BE CHANGED IF REQUIRED. CUSTOMIZE WHEN CUSTOMIZE IS SELECTED IT ALLOWS THE ASSIGNMENT OF TWO VOICE FREQUENCY CHANNELS (VF1 AND VF2), TWO DATA CHANNELS (V11-1 AND V11-2) AND OPTIONAL LAN CARD INTERFACE. CLICK EXECUTE TO CARRY OUT THE SETTING AND CLICK CLOSE TO EXIT THE SETTING WINDOW.
TO USE CUSTOMIZE SETTING CLICK CHANNEL USAGE BUTTON TO OPEN THE CHANNEL USAGE SETTING WINDOW. TO CHANGE THE DIRECTION OF V11 CHANNELS CLICK DIRECTION BUTTON AND SELECT CO-DIRECTION OR CONTRA-DIRECTION. THIS SETTING IS AVAILABLE FOR BOTH EASY AND CUSTOMIZE.
IF ANY OF THE VOICE, DATA AND LAN CHANNELS ARE NOT USED DESELECT THE USED SETTING CLICK EXECUTE BUTTON TO ASSIGN THE CUSTOMIZE SETTING. CLICK CLOSE TO EXIT
TO ASSIGN ANY OH CHANNEL TO VOICE, DATA OR LAN CHANNEL, CLICK THE BUTTON INTERSECTING THE COLUMN AND ROW. SELECTED SETTING IS SHOWN IN GREEN,
PNMT
29
THERE ARE SEVERAL TYPES OF OPTIONAL SUB INTERFACE CARDS AVAILABLE FOR PASOLINK PLUS EQUIPMENT. SUB INTERFACE SETTING IS AVAILABLE FROM THE PROVISIONING WINDOW. SELECT NOT USED WHEN SUB INTFC CARD IS MOUNTED BUT NOT USED.. SELECT WS INTFC WHEN THE WS INTFC CARD IS MOUNTED AND USED.. SELECT WS/CLUSTER ALARM WHEN THAT OPTION CARD IS MOUNTED AND USED.. SELECT CLUSTER ALARM WHEN THE CLUSTER ALARM CARD IS MOUNTED AND USED.. SELECT 10BASE-T WHEN THE LAN CARD IS MOUNTED AND USED..
TO USE THE SUB INTFC OPTION CLICK THE SUB INTFC BUTTON. TO SELECT THE TYPE OF WS INTFC USED, CLICK THE WS INTFC BUTTON AND FROM THE WS INTFC SETTING WINDOW SELECT THE WS INTFC TYPE
LAN CARD
THIS OPTION IS AVAILABLE WITH BOTH 32 QAM AND 128 QAM SYSTEMS. 32 QAM SYSTEMS USE THE RFCOH AT A RATE OF 2.048 MBPS 128QAM SYSTEMS USE THE OH ASSIGNMENT TO SELECT DSC OR RSOH (E1/F1) AT A RATE OF 64 KBPS. THE SWITCH ON THE LAN CARD SHOULD BE SET TO CROSS OR STRAIGHT ACCORDING TO THE TYPE OF LAN CABLE USED.
WHEN 1.5 MB IS SELECTED THE LINE LENGTH OF THE WS INPUT SIGNAL SHOULD BE SELECTED. CLICK THE WS LINE LENGTH BUTTON TO OPEN THE SETTING WINDOW.
CLICK EXECUTE TO IMPLEMENT THE SELECTED WS INTFC OPTION
PNMT
30
ATPC SETTING
AUTOMATIC TX POWER CONTROL
ATPC RANGE DEFINES THE MAXIMUM AND MINIMUM TRANSMISSION POWER DURING ATPC OPERATION. IN MTPC MODE THIS MENU ITEM DOES NOT APPEAR. VALUE SET IS THE ATTENUATION IN dB FROM MAX ODU POWER. IF THE MAXIMUM OUTPUT POWER OF THE ODU IS +20 DBM, THEN FOR AN ATPC MAX PWR SETTING OF 0DB AND ATPC MIN PWR SETTING OF -10DB, THE ODU OUTPUT POWER DURING ATPC OPERATION CAN VARY BETWEEN +20 DBM AND +10 DBM
ADDITIONAL ATTENUATION
ADDITIONAL ATTENUATION IS A SPAN ATTENUATOR USED TO REDUCE THE TX POWER IN SITUATIONS LIKE SHORT HOP LENGTH. THE ATPC CONTROLLED OUTPUT POWER OR MTPC SET OUTPUT POWER, WILL BE REDUCED BY THE SET ATTENUATION VALUE.
CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW.. AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING. IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW MAX HOLD: SET THE ODU OUTPUT TO THE ATPC MAXIMUM POWER LEVEL MINIMUM HOLD: SET THE ODU OUTPUT TO THE ATPC MINIMUM POWER LEVEL HOLD: SET THE ODU OUTPUT TO THE LEVEL AT THE TIME OF IDU-ODU CONTROL COMMUNICATION FAILURE.
PNMT
31
MTPC SETTING
MTPC TX POWER MTPC TX PWR DEFINES THE ODU OUT PUT POWER IN MTPC MODE. THE VALUE ENTERED IS THE ATTENUATION LEVEL IN DB FROM THE MAXIMUM ODU OUTPUT POWER. IN ATPC MODE THIS MENU ITEM DOES NOT APPEAR. 32 QAM SYSTEM 0 TO 23 DB 128QAM SYSTEM 0 TO 20 DB TO GET THE MAXIMUM OUTPUT POWER SET THE ATTENUATION TO 0DB. RX THRESHOLD LEVEL IN MTPC MODE THIS VALUE IS SET, IN CASE THE OPPOSITE STATION IS SET TO ATPC MODE. THEN, IF THE MONITORED RX SIGNAL LEVEL FALLS BELOW THIS LEVEL, CONTROL SIGNAL SENT TO THE OPPOSITE STATION INITIATE THE ATPC FUNCTION.
IN THE PROVISIONING WINDOW THE MTPC STATUS IS ACTIVE WHEN THE TX POWER CONTROL MODE IS SET TO MTPC..
CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW.. AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING. IN ALL SETTING WINDOWS, CLICK CLOSE TO EXIT THE WINDOW
ADDITIONAL ATTENUATION
ADDITIONAL ATTENUATION IS A SPAN ATTENUATOR USED TO REDUCE THE TX POWER IN SITUATIONS LIKE SHORT HOP LENGTH. THE ATPC CONTROLLED OUTPUT POWER OR MTPC SET OUTPUT POWER, WILL BE REDUCED BY THE SET ATTENUATION VALUE. SETTING RANGE 1 TO 5 dB.
PNMT
32
10/100BASE-T SETTING
PORT1/PORT MODE AND DUPLEX SETTING SETS THE MODE USED AND DUPLEX SETTING. DEPENDS ON THE EXTERNAL EQUIPMENT SETTING. PORT USAGE SETS THE RATE USED BY PORT1 AND PORT2
IN THE PROVISIONING WINDOW THE 10/100BASE-T CONTROLS ARE ACTIVE WHEN THE WHEN THE 10/100BASE-T MAIN INTFC CARD IS MOUNTED
FAR END LINK DOWN WHEN THE LINK IS DOWN SENDS THE INFORMATION TO THE FAR END TO DISCONNECT THE FAR END LINK. THIS FUNCTION CAN BE ENABLED OR DISABLED.
CLICK THE APPROPRIATE BUTTON TO OPEN THE SELECTED SETTING WINDOW.. AFTER SELECTING OR SETTING THE PARAMETER CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING.
CLOCK SOURCE
SELECTS THE CLOCK USED BY THE LAN PORT
PNMT
33
PROVISIONING WINDOW
E-11
E-03
E-04
E-05
E-06
E-07
E-08
E-09
E-BER(DMR) EXCESSIVE BER LEVEL FOR RADIO SECTION. SET WORSE THAN THE SWITCHOVER LEVEL. SD(DMR) SIGNAL DEGRADE BER LEVEL FOR RADIO SECTION.
E-BER(DMR) E-BER(MUX)
SD (DMR) SD (MUX)
E-BER(MUX) EXCESSIVE BER DETECT LEVEL FOR INPUT STM-1 SIGNAL FROM THE MUX. SD(MUX) SIGNAL DEGRADE ALARM LEVEL FOR INPUT STM-1 SIGNAL FROM THE MUX IN THE PROVISIONING WINDOW THE MTPC
E-12
PNMT
34
CLICK THE APPROPRIATE BUTTON IN THE PROVISIONING WINDOW THRESHOLD SECTION TO OPEN THE REQUIRED BER SETTING WINDOW..
AFTER SELECTING THE BER ALARM THRESHOLD VALUE, CLICK EXECUTE BUTTON TO IMPLEMENT THE SETTING.
PNMT
35
MAINTENANCE
CLICK MAINTENANCE, ON THE, CONFIGURATION DROP DOWN MENU TO OPEN THE MAINTENANCE WINDOW
TO CARRY OUT ANY MAINTENANCE CONTROL ,SET THE SELECTED NE TO MAINTENANCE MODE. CLICK THE MAINT BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE MAINTENANCE MODE SELECTION WINDOW. SELECT MAINT MODE ON OR OFF AND CLICK EXECUTE TO IMPLEMENT THE MODE SELECTION
THESE CONTROL ARE AVAILABLE FOR (1+1) CONFIGURATION. PROVIDES MANUAL SWITCH OVER OF PASOLINK CHANNEL FOR NORMAL OPERATION SELECT AUTO FOR AUTO REDUNDANCY SWITCHING.. ALS RESTART IS ACTIVE ONLY WHEN OPTICAL INTFC IS USED
BEFORE TRYING TO CONTROL ANY MAINTENANCE FUNCTION SET THE SELECTED EQUIPMENT TO MAINTENANCE MODE. OTHERWISE AN ERROR MESSAGE. WILL BE DISPLAYED
PNMT
36
CLICK THE MAIN SIGNAL LP BACK 2 BUTTON TO OPEN THE FAR END LOOPBACK CONTROL WINDOW
SELECT LOOPBACK ON OR OFF AND CLICK ON EXECUTE TO ENABLE NEAR END LOOPBACK ON THE SELECTED CHANNEL. CLICK CLOSE TO EXIT THE LOOPBACK CONTROL WINDOW.. SELECT LOOPBACK ON OR OFF AND CLICK ON EXECUTE TO ENABLE FAR END LOOPBACK ON THE SELECTED CHANNEL. CLICK CLOSE TO EXIT THE LOOPBACK CONTROL WINDOW.. IF LOOP BACK IS NOT AVAILABLE FOR A REMOTE NE
SELECT LOOPBACK ON OR OFF AND CLICK ON EXECUTE TO ENABLE FAR END LOOPBACK ON THE SELECTED CHANNEL. CLICK CLOSE TO EXIT THE LOOPBACK CONTROL WINDOW..
PNMT
37
MAINTENANCE
THIS CONTROL SETS THE DURATION THAT THE LASER IS ON, WHEN ALS MANUAL RESTART CONTROL IS PERFORMED. CLICK THE ALS RESTART BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE ALS RESTART CONTROL WINDOW. SELECT THE DURATION OF THE LASER BURST AND CLICK EXECUTE TO IMPLEMENT THE ALS MANUAL RESTART CONTROL.
THIS CONTROL TRANSMIT AN UN- MODULATED CARRIER FOR MEASUREMENT PURPOSE. THIS CONTROL MAY INTERRUPT TRAFFIC. CLICK THE CW (MOD CARRIER) BUTTON ON THE MAINTENANCE WINDOW TO OPEN THE CW CONTROL WINDOW. CLICK ON OR OFF AND EXECUTE TO IMPLEMENT THE MAINTENANCE CONTROL. THIS CONTROL SWITCH OFF OR MUTE THE TX OUTPUT POWER OF ODU1/ODU2 OF THE SELECTED NE. THIS MAY INTERRUPT THE TRAFFIC TO CLOSE ANY MAINTENANCE CONTROL WINDOW CLICK CLOSE BUTTON. TO NORMALIZE MAINTENANCE MODE NORMALIZE ALL MAINTENANCE CONTROLS FIRST. CLICK THE TX MUTE BUTTON ON CH1 OR CH2 ON THE MAINTENANCE WINDOW TO OPEN THE TX MUTE CONTROL WINDOW. CLICK ON/OFF AND EXECUTE TO IMPLEMENT THE MAINTENANCE CONTROL.
PNMT
38
MAINTENANCE
THIS CONTROL CAN CHANGE THE TX FREQUENCY OF ODU1 OR ODU 2 OF THE SELECTED NE. WHEN THE TX FREQUENCY IS CHANGED CORRESPONDING RX FREQUENCY IS AUTOMATICALLY DISPLAYED. THIS CONTROL MAY INTERRUPT THE TRAFFIC. CLICK THE TX FREQUENCY BUTTON ON CH1 OR CH2 ON THE MAINTENANCE WINDOW TO OPEN THE TX/RX FREQUENCY CONTROL WINDOW. CHANGE THE TX FREQUENCY AND CLICK EXECUTE TO IMPLEMENT THE MAINTENANCE CONTROL.
THIS CONTROL SET THE ATPC CONTROL TO MANUAL AND ADJUST THE OUTPUT POWER CLICK THE ATPC MANUAL BUTTON OF CH1 OR CH2 ON THE MAINTENANCE WINDOW TO OPEN THE ATPC MANUAL CONTROL WINDOW. SELECT THE ATPC MANUAL ON/OFF. IF ON SELECT THE REQUIRED ATT TO TX THE REQUIRED OUT POWER. THEN CLICK EXECUTE TO IMPLEMENT THE MAINTENANCE CONTROL. TO CLOSE ANY MAINTENANCE CONTROL WINDOW CLICK CLOSE BUTTON. TO NORMALIZE MAINTENANCE MODE NORMALIZE MAINTENANCE CONTROLS FIRST.
PNMT
39
AUXILIARY INPUT / OUTPUT FACILITY CAN BE USED TO MONITOR SIX EXTERNAL MONITOR ITEMS AND FOUR EXTERNAL CONTROL ITEMS USING THE PASOLINK MANAGEMENT SYSTEM. MONITORING ITEMS ARE CONNECTED THROUGH OPTICAL COUPLERS AND CONTROLS VIA RELAYS. THESE ITEMS ARE ALSO KNOWN AS HOUSEKEEPING ALARMS AND CONTROLS.
ENTER THE NAME TO APPEAR FOR SELECTED CONTROL ITEM ( UP TO 32 CHARACTERS) ENTER THE LABEL FOR EACH CONDITION EVENT ON AND EVENT OFF CLICK EXECUTE TO CARRY OUT THE CHANGE
ENTER THE SELECTED EXTERNAL ALARM NAME, (UP TO 32 CHARACTERS) CONFIGURE ALARM INPUTS CLICK THE INPUT 1-6 BUTTONS TO CONFIGURE THE EXTERNAL ALARM SELECT THE CONDITION FOR ALARM, EVENT ON OR EVENT OFF EXTERNAL MONITORING ITEMS CAN BE DEFINED AS ALARMS OR AS STATUS CHANGE. CLICK EXECUTE TO CARRY OUT THE CHANGE
ENTER THE LABEL FOR ALARM/ STATUS EVENT ON AND EVENT OFF. X.733 ALARM/SEVERITY SETTING
PNMT
40
RELAY CONFIGURATION
CONFIGURING THE TWO PARALLEL INTERFACE CONNECTORS, ALM AND ALM/AUX CAN BE CARRIED OUT FROM THIS MENU. ALTOGETHER 8 RELAY OUTPUTS (RL4 TO RL11) CAN BE CONFIGURED FOR OUTPUTTING EQUIPMENT ALARMS. OUT OF THE 8 RELAYS, FOUR CAN BE CONFIGURED TO CONTROL EXTERNAL HOUSEKEEPING EQUIPMENT. RL01 TO RL03 ARE ASSIGNED TO MAINT, PS ALM AND CPU ALM AND CANNOT BE CHANGED. RL08 TO RL11 CAN BE ASSIGNED TO THE FOUR HOUSE KEEPING CONTROL OUTPUTS. IF THE RELAYS ARE NOT ASSIGNED TO OUTPUT HOUSE KEEPING CONTROL, THEY CAN BE ASSIGNED TO OUTPUT EQUIPMENT ALARMS. RL04 TO RL07 CAN BE ASSIGNED TO ABOUT 23 EQUIPMENT ALARMS. MORE THAN ONE ALARM CAN BE ASSIGNED TO A RELAY CLICK THE RELAY CONFIGURATION BUTTON IN THE AUX I/O WINDOW TO OPEN RELAY CONFIGURATION SETTING WINDOW SELECT THE NUMBER OF HOUSE KEEPING CONTROLS OR SELECT DISABLE. IF HK IS INDICATED UNDER RL08 TO RL11 THEY ARE USED FOR HK CONTROL IF NOT THEY CAN USED FOR ALARMS.
RL04 TO RL07 CAN BE ASSIGNED ANY EQUIPMENT ALARM BY CLICKING ON THE BUTTON INTERSECTING THE ALARM ROW AND RELAY COLUMN. THE SELECTED BUTTON WILL CHANGE COLOR TO GREEN.
PNMT
41
CLICK THE VERSION TAB TO DISPLAY THE VERSION INFORMATION WINDOW FOR THE SELECTED NE.
CONFIGURATION AND SETTING OF THE PASOLINK MANAGEMENT CONTROL IS PROVIDED IN THIS WINDOW.
VERSION WINDOW DISPLAY THE DATE OF MANUFACTURE , SOFTWARE VERSIONS, SERIAL NUMBER, CODE NUMBER ETC.. OF THE PASOLINK EQUIPMENT IN THE SELECTED NETWORK ELEMENT.
PNMT
42
DATE AND TIME STORED IN THE SELECTED NETWORK ELEMENTS PM CTRL CAN BE DISPLAYED AND ADJUSTED FORM THIS CONTROL ITEM
TO DISPLAY THE CURRENT DATE/TIME STORED IN THE NE, SELECT GET DATE/TIME AND CLICK EXECUTE. CLICK DATE/TIME BUTTON IN THE CTRL WINDOW TO OPEN THE DATE/TIME SETTING CONTROL WINDOW THE CURRENT DATE/TIME STORED IN THE PM CARD, IS DISPLAYED.
TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME. TO DISPLAY AND SET THE DATE/TIME SET IN THE PNMT PC TO THE NE, SELECT DISPLAY PC TIME BOX AND CLICK THE EXECUTE BUTTON.
TO CHANGE THE PM CARD DATE TIME SETTING, SELECT SET DATE/TIME. CHANGE THE DATE /TIME SETTING AS REQUIRED, CLICK THE EXECUTE BUTTON.
PNMT
43
THIS FUNCTION IS USED TO DOWN LOAD CONFIGURATION FILES CREATED BY THE NETWORK CONFIG TOOL TO THE CTRL IN THE SELECTED NETWORK ELEMENT. THERE ARE TWO FILES CREATED FOR EACH NE, MIB.CFG CONTAINS THE IP ADDRESS OF THE NE AS WELL AS THE IP ADDRESS OF THE OPPOSITE STATION. THE NETWORK.CFG FILE CONTAINS THE INFORMATION ABOUT THE PASOLINK NETWORK WHERE NE IS LOCATED.
DOWN LOAD SELECT EACH CONFIG FILE ONE BY ONE FROM THE TYPE WINDOW BROWSE AND SELECT THE PATH/LOCATION TO THE FILE SELECTED IN THE TYPE WINDOW. CLICK EXECUTE BUTTON TO DOWN LOAD THE SELECTED CONFIG FILE.. REPEAT THE DOWNLOAD PROCEDURE FOR THE OTHER CONFIG FILE.. A MESSAGE WINDOW INDICATE THE STATUS OF THE DOWNLOAD OPERATION AND IT WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS OVER
UPDATE AFTER THE SUCCESSFUL DOWN LOAD OF THE CONFIGURATION FILES. CLICK UPDATE BUTTON. UPDATE CONFIGURATION FILE WINDOW OPENS. SELECT THE APPROPRIATE BOX FOR THE TYPE OF CONFIGURATION FILE(S) THAT WILL BE UPDATED. CLICK EXECUTE BUTTON TO START THE UPDATE OPERATION.. WHEN UPDATING, PM CTRL TO PM CTRL COMMUNICATION WILL BE LOST WHEN CTRL INITIALIZES TO THE NEW SYSTEM CONFIGURATION. DURING THIS TIME PNMT CONNECTION TO THE PASOLINK WILL BE LOST BUT WILL AUTOMATICALLY BE RECONNECTED AFTER THE PM CTRL RESETS Network Config MIB Config
With ROM [CTRL Program] Switching
WARNING MAKE SURE THAT THE CORRECT CONFIGURATION FILE IS DOWN LOADED TO THE CTRL IN THE CORRECT NE. INCORRECT CONFIGURATION FILE WILL LEAD TO CTRL OR NETWORK FAILURE MAKE SURE THAT YOU HAVE SUCCESSFULLY DOWN LOADED THE CONFIGURATION FILE BEFORE DOING UPDATE. OTHERWISE THE CTRL WILL SWITCH TO AN EMPTY ROM THAT MAY CAUSE CTRL FAILURE. CLICK CLOSE BUTTON WHEN DONE
Execute
PNMT
44
CTRL CAN BE RESET USING THIS FUNCTION CLICK THE CTRL RESET BUTTON ON THE CTRL WINDOW. A:\pm.pof
SELECT THE MODULE THE APPLICATION PROGRAM IS TO BE DOWNLOADED. ENTER THE PATH TO THE PROGRAM FILE TO BE DOWNLOADED OR CLICK BROWSE TO LOCATE THE PROGRAM FILE. CLICK THE EXECUTE BUTTON TO START DOWNLOAD OPERATION CLICK ON THE CPU RESET BUTTON TO SWITCH TO THE NEW PROGRAM FILE SELECT WITH ROM (PROGRAM) SWITCHING OPTION IF YOU WANT TO SWITCH TO A NEWLY DOWNLOADED CTRL PROGRAM FILE RESETTING THE CTRL WILL NOT AFFECT THE TRAFFIC. THE CONNECTION TO THE SELECTED PASOLINK WILL BE LOST FOR FEW MINUTES AND WILL BE RECONNECTED AUTOMATICALLY. DOWNLOAD PROGRESS IS INDICATED HERE
WARNING MAKE SURE THAT THE CORRECT PROGRAM FILE IS DOWNLOADED TO THE CTRL. INCORRECT PROGRAM FILE WILL LEAD TO CTRL FAILURE.
PNMT
45
WHEN EQUIPMENT IS CONFIGURED (AUXILIARY ALARMS, BER THRESHOLD ETC.) TAKE A UPLOAD OF THE EQUIPMENT CONFIGURATION FILE TO THE PNMT PC.
CLICK THE CONFIGURATION FILE UNDER THE UPLOAD (CTRL>>PC) TO OPEN THE UPLOAD CONFIGURATION FILE WINDOW.
WHEN THE PASOLINK IDU FOR A SITE IS REPLACED FOR SOME REASON THE EQUIPMENT CONFIGURATION FILE CAN BE DOWN LOADED TO CONFIGURE THE REPLACED IDU.
SELECT THE TYPE OF CONFIG FILE TO BE UPLOADED FROM THE TYPE WINDOW., MIB CONFIG OR NETWORK CONFIG. ENTER THE LOCATION THE FILE TO BE UPLOADED AND THE FILE NAME IN THE FILE WINDOW. USE BROWSE TO LOCATE THE DIRECTORY IF NECESSARY. CLICK EXECUTE BUTTON TO START THE UPLOAD OPERATION. A MESSAGE WINDOW APPEARS TO SHOW THE STATUS OF THE UPLOAD OPERATION, AND WILL CLOSE AUTOMATICALLY ONCE THE OPERATION IS COMPLETED.. AFTER THE UP LOAD IS FINISHED CLICK THE CLOSE BUTTON TO CLOSE THE WINDOW. AFTER DOWN LOADING, CARRY OUT THE UPDATE OPERATION
PNMT
46
Latest 1
Event Log File Day 1 20020911
Oldest 300
EVENT LOG AND PERFORMANCE DATA ARE UPLOADED TO THE PNMT EACH TIME EVENT LOG AND PERFORMANCE MONITOR ARE SELECTED.
Day #1
Events Status Change Alarm Occurrence Alarm Recovery Controls Parameter Change
PNMT
47
EVENT LOG
NE SPECIFIC MENU BAR A MESSAGE WINDOW SHOWS THE PROGRESS OF THE UPLOAD CLICK ON THE EVEN LOG IN THE NE SPECIFIC MENU BAR TO UPLOAD THE EVEN LOG ITEMS FROM THE SELECTED NE.
EVENT LOG VIEW WINDOW SHOWS ALARM EVENTS, COMMAND EVENTS AND STATUS CHANGES. DIFFERENT COLORS SHOWS THE TYPE OF EVENT. EVENT LOG IS PRESENTED IN A TABLE FORM SHOWING THE DATE OF THE EVENT , THE ITEM THAT TRIGGERED THE EVENT AND THE STATUS CHANGE.
CLICK FILE-UPLOAD TO REFRESH THE EVENT LOG DISPLAY CLICK FILE-SAVE AS TO SAVE THE EVENT LOG TO CLICK FILE-PRINT TO PRINT THE EVENT LOG INFORMATION
PNMT
48
THE FOLLOWING PERFORMANCE ITEMS CAN BE MONITORED ACCORDING TO THE G.826 RECOMMENDATIONS.
CURRENT BER VALUE IS SHOWN IN THIS FIELD THE RED COLOR IN THE PERFORMANCE MONITOR WINDOW INDICATES THE OCCURRENCE OF PERFORMANCE ITEMS EXCEEDING THE THRESHOLD VALUE. THE THRESHOLD VALUES CAN BE SET IN THRESHOLD WINDOW.
THRESHOLD VALUE SETTING CLICK THE THRESHOLD BUTTON MUX OR DMR TO OPEN THE THRESHOLD SETTING WINDOW. SELECT THE PERFORMANCE ITEM THAT IS TO BE CONFIGURED ON THE TABLE SHOWN. SET THE VALUE WHEN THE ALARM OCCUR AND WHEN THE ALARM RECOVER IN THE APPROPRIATE FIELD. AFTER SETTING ALL THE THRESHOLD VALUES CLICK EXECUTE TO ACTIVATE THE NEW SETTING. CLOCK CLOSE TO CLOSE THE THRESHOLD SETTING WINDOW..
PNMT
49
THIS WINDOW CONTAINS THE LINK PERFORMANCE DATA OF THE LAST .8 DAYS.
THE DATE BUTTONS ON THE RIGHT HAND SIDE OF THE TABLE ARE SELECTABLE. AND CAN OPEN THE SUMMARY DATA FOR THAT SPECIFIC DATE..
CLICK ON A DATE BUTTON TO DISPLAY THE DAILY DATA WINDOW FOR THE SELECTED DATE THE LINK PERFORMANCE MONITOR DAILY DATA WINDOW DISPLAY THE DETAILED 15MIN PERFORMANCE DATA
CLICK FILE - UPLOAD TO REFRESH THE DATA CLICK FILE SAVE AS TO SAVE THE DATA IN TEXT FORMAT CLICK FILE CLOSE TO EXIT THE WINDOW
PNMT
50
Entry1=N0.001,172.18.0.1
START THE PNMT AND FROM THE CONNECT LIST SECTION WINDOW SELECT ETHERNET AND THE NE TO BE CONNECTED.
SEE THE PNMT-SETTING MANUAL FOR LAN CONNECTION FOR MORE DETAILS
PNMT
51
LIST THE NE NAMES AND THE IP ADDRESS OF THE ROOT OR CPM NEs TO BE CONNECTED. THE NUMBER OF ETHERNET ENTRIES IS UP TO 32.
CREATE A ROUTE COMMAND BATCH (ROUTE_SAMPLE.BAT) FILE TO ADD THE ROUTING TABLE IN PNMT PC.
Route add 172.18.0.0 mask 255.255.255.0 192.168.1.1 Route add 172.18.1.0 mask 255.255.255.0 192.168.1.2 Route add 172.18.31.0 mask 255.255.255.0 192.168.1.32
DOUBLE-CLICK THE ROUTE_SAMPLE.BAT FILE TO ACTIVATE THE ROUTING TABLE. HUB START THE PNMT AND FROM THE CONNECT LIST SECTION WINDOW SELECT ETHERNET AND THE NE TO BE CONNECTED.
PNMT
52