Está en la página 1de 71

s

the living company

LIOS V8.6 Administrat or

LIOS 8.6 Administrator


1

Siemens IT Solutions and Services


14/06/12

s
the living company

LIOS administrator
User administration NE administration EFD administration LEA administration

LIOS 8.6 Administrator


2

Siemens IT Solutions and Services


14/06/12

s
the living company

User administration
LIOS user roles: Operator External Operator Supervisor Administrator

LIOS 8.6 Administrator


3

Siemens IT Solutions and Services


14/06/12

s
the living company

LIOS operator
Issuing, modifying and canceling observations (observation handling) Synchronization of LIOS and NE databases (observation management) LEA administration Alarm browser BMML console

LIOS 8.6 Administrator


4

Siemens IT Solutions and Services


14/06/12

s
the living company

LIOS supervisor
Log browser Observation browser Ticket browser Alarm browser BMML console

LIOS 8.6 Administrator


5

Siemens IT Solutions and Services


14/06/12

s
the living company

LIOS administrator
User administration NE and LIOS server administration EFD administration LEA administration Alarm browser BMML console

LIOS 8.6 Administrator


6

Siemens IT Solutions and Services


14/06/12

s
the living company

LIOS administrator interface

LIOS 8.6 Administrator


7

Siemens IT Solutions and Services


14/06/12

s
the living company

The LIOS main page


Header Application commands bar Navigation menu

Work area

LIOS 8.6 Administrator


8

Siemens IT Solutions and Services


14/06/12

s
the living company

LIOS user administration


Managing LIOS users and LIOS operator groups

LIOS 8.6 Administrator


9

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating a LIOS operator (I)


Select New user from the application commands Under user role select internal operator

LIOS 8.6 Administrator


10

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating a LIOS operator (II)


Select the operator rights for this operator LEA administration: operator can administer LEAs MML handling: operator can use BMML console Observation handling: operator can create, modify and cancel observations Observation Manager: operator can invoke DB synchronisation Select operator group

LIOS 8.6 Administrator


11

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating a LIOS administrator

LIOS 8.6 Administrator


12

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating a LIOS supervisor

LIOS 8.6 Administrator


13

Siemens IT Solutions and Services


14/06/12

s
the living company

Operator groups
Every operator has to belong to one or more operator groups. Apart from global alarms, an operator receives only alarms that concern his group(s). An operator can only see the observations of operators of his group(s).

LIOS 8.6 Administrator


14

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating operator groups


Select items from the available operator groups list on the left and press the > button. The items are shifted to the selected operator groups list. To shift all items press the >> button.

LIOS 8.6 Administrator


15

Siemens IT Solutions and Services


14/06/12

S
the living company

Host Administration

Titel der Prsentation LIOS 8.6 Administrator 16

Siemens IT Solutions and Services


14/06/12

Communication database in LIOS and on the NE


IP configuration has to be performed both in the LIOS system and on the NE (e.g. EWSD, S12, SR9, KCC, HUAWEI, . . .). For IP configuration in the LIOS system use Host Admininstration/NEs. The corresponding entries in the communicaton database of the NE are not administered in the LIOS system. They have to be entered by an NE administrator on the NE.

the living company

LIOS 8.6 Administrator


17

Siemens IT Solutions and Services


14/06/12

S
the living company

LIOS-specific configuration of EWSD switches

Titel der Prsentation LIOS 8.6 Administrator 18

Siemens IT Solutions and Services


14/06/12

Administration of Exchange ID and User IDs


/****************************************************************** /* * /* Administration of Exchange ID and USERIDs * /* * /****************************************************************** /* <ENTREXCHID:NAME=T8000,NSYT=0&2,IDNO=T8000; /* <CRUSERID:USERID=MFKONTES,AUT=1; *MFKON-0 *MFKON-0 <CRUSERID:USERID=DBPLIM12,AUT=1; *SYSTEM-2 *SYSTEM-2

the living company

LIOS 8.6 Administrator


19

Siemens IT Solutions and Services


14/06/12

s
the living company

Local entries for LIOS: MMLCM / FTP


/****************************************************************** /* * /* MMLCM Local (on CP) * /* * /****************************************************************** /* /* Local ipadr for efdad, mmlcm, efdli and fta /* <CRIPADR:ADRNAM=IPAOWN; already configured /* /* Local application for observation administration /* <CRAPPL:APPLID=MMLCM,PRONAM="T8000",ADRNAM=IPAOWN,TSEL= #005B,SSEL=000B,PSEL=000B,AET=0&2&262&1&1&8000&91; /* /****************************************************************** /* UserID for FTP on MP * /******************************************************************

Local IP address MMLCM application: for observation handling and MML communication

/* CRFTINI:User identity="FELKEL",Password type=Simple PW, Password=********,Verify password=********,Ft type={ FTP }; /*

For Powernode switches connected via IP FTP is used for file transfer. This is needed for Ticketbuffer management and exchanging security keys for EWSD <V17. Therefore only a User ID on the MP is necessary.

LIOS 8.6 Administrator


20

Siemens IT Solutions and Services


14/06/12

s
the living company

Remote entries for LIOS: MMLCM


/****************************************************************** /* * /* Remote entries for LIOS * /* * /****************************************************************** /* /* Remote processors for LIOS (TS1 and TS2) <CRPRO:PRONAM="LIOS1",PROTYP=OSS,SYT=0&2&262&1&1&3001; <CRPRO:PRONAM="LIOS2",PROTYP=OSS,SYT=0&2&262&1&1&3002; /* <CRIPADR:ADRNAM=IPALIOS1,IPADR=10-119-146-85; <CRIPADR:ADRNAM=IPALIOS2,IPADR=10-119-146-86; /* /* Remote applications for observation administration (MMLCM) /* <CRAPPL:APPLID=MMLCM,PRONAM="LIOS1",ADRNAM=IPALIOS1,AUT=1, #TSEL=005B,SSEL=000B,PSEL=000B,AET=0&2&262&1&1&3001&91; <CRAPPL:APPLID=MMLCM,PRONAM="LIOS2",ADRNAM= IPALIOS2,AUT=1, #TSEL=005B,SSEL=000B,PSEL=000B,AET=0&2&262&1&1&3002&91; /*

Remote processor names for LIOS servers Remote entries for MMLCM. These entries are the values for the LIOS servers.

LIOS 8.6 Administrator


21

Siemens IT Solutions and Services


14/06/12

NET.CONFIG - Used for EFD and LID Admin


/******************************************************* /***** EFD Administration ***** /******************************************************* / LOSIADR: APT=0-2-262-1-1-8004-2020, PSEL=2020, SSEL=2020, # AC =2-9-0-0-2; ROSIADR: APT=0-2-262-1-1-2001-2020, PSEL=2020, SSEL=2020, # PORT =102, # IPADR=172-30-1-25; / /******************************************************* /***** LID Administration ***** /******************************************************* / LOSIADR: APT=0-2-262-1-1-8004-1010, PSEL=1010, SSEL=1010, # AC =2-9-0-0-2; ROSIADR: APT=0-2-262-1-1-2001-1010, PSEL=1010, SSEL=1010, # PORT =102, # IPADR=172-30-1-25; / TSEL=2020, TSEL=2020,

the living company

EFDAD application: for EFD administration EFDLI application: for sending LI tickets and LI alarms from EWSD to LIOS

TSEL=1010, TSEL=1010,

LIOS 8.6 Administrator


22

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration
The Host Administration is used for administering the IP and OSI configuration data for the communication between NE (= EWSD, S12, SR9, ...) and LIOS server. The corresponding entries in the IP database of the NE are not administered by a LIOS administrator. They have to be entered by an NE administrator. The Host Administration contains data for LIOS servers all NEs connected to LIOS global LIOS configuration

LIOS 8.6 Administrator


23

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration NEs

LIOS 8.6 Administrator


24

Siemens IT Solutions and Services


14/06/12

S
the living company

Administering an EWSD switch (example)

Titel der Prsentation LIOS 8.6 Administrator 25

Siemens IT Solutions and Services


14/06/12

Host Administration General data EWSD (I) Provider. Abbreviated name of the

the living company

network provider; length: normally two characters NE name. Name of the NE (has to be identical with the NE name used on the NE itself, specified by the ENTREXCHID command) Long NE name. Any name which specifies the NE, e.g. name of location NE type. Siemens fixed, Siemens mobile or Alcatel fixed NE version. Software version of the switch (e.g. EWSD V15) Time zone. If the time zone of the NE and LIOS differ, enter here the time zone of the NE.

LIOS 8.6 Administrator


26

Siemens IT Solutions and Services


14/06/12

Host Administration General data EWSD (II)


Values used for the ETSI HI2 and HI3 interfaces Operator ID is used in HI2 and HI3 The NE ID can be entered in four different formats: E.164, X25, IP, DNS (this is only for HI2).

the living company

LIOS 8.6 Administrator


27

Siemens IT Solutions and Services


14/06/12

Host Administration LI NE passwords (I)


LI group command password. The LI group command password is needed for controlling most LI functions on the NE (creating/modifying LEAs and observations). To be able to specify or modify the LI group command password, you must know the LI ID password. LI ID password. It is needed for specifying or modifying the LI group command password and the audit password. The LI ID password replaces the hard-coded LI password. The LI ID password protects the EWSD command MOD OBSID. LI audit password. It is needed for invoking LI audit functions (e.g. DISP LIMEAS). To be able to specify or modify the audit password, you must know the LI ID password.

the living company

LIOS 8.6 Administrator


28

Siemens IT Solutions and Services


14/06/12

Host Administration Optional features (I) Ticket buffer management activated.


Optional. If this feature is activated on the NE (EWSD stores tickets in a buffer after 24 hours of ticket transfer failure). LIOS retrieves tickets from this buffer automatically. NE identification number. Optional. Freely chosen unique number for EWSD; included in tickets. ETSI V2 allowed. Only for EWSD V17 / hiE9200 V3. Selection of the ETSI_V2 signaling schemes is allowed. The corresponding LI property must be set on the NE. TR TKUE 40 active. Only for EWSD V17 / hiE9200 V3. The NE uses the German variant of ETSI_V2. If you select this check box, also ETSI V2 signaling must be selected. The corresponding LI property must be set on the NE.

the living company

Realized as powernode. Optional. If the switch is a powernode and replayprotect password is used for EFD administration and FT, then this must be ticked. CUG indexing activated. Optional. If selected the CUG of the LEA can be addressed through a CUG index (this can only be used if on the EWSD the LEA is a member of a CUG, CUG indexing is administered, the responding flag is set in the LI option and in the LIOS LEA administration the corresponding indices have been defined). NE directory number. Optional. Virtual directory number of the switch, which is displayed (CLIP) on the LEA equipment when the call to the LEA is established.
Siemens IT Solutions and Services
14/06/12

LIOS 8.6 Administrator


29

Host Administration Transport system

the living company

For TCPI/IP: Enter IP Adress

LIOS 8.6 Administrator


30

Siemens IT Solutions and Services


14/06/12

Host Administration adding an application

the living company

To set up an application for this NE press New.

LIOS 8.6 Administrator


31

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration Administering MMLCM for EWSD (I)


Application. Here MMLCM is being set up. Primary LIOS server. Here you specify which LIOS server should send MML commands to the NE; the other LIOS server will work as a backup. Port number. Specify which port of the Symicron card is used.

LIOS 8.6 Administrator


32

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration Administering MMLCM for EWSD (II)


Transport, Session, Presentation selector. Enter the selectors which are administered on the X.25/IP database on the NE System title, APQ. Enter the corresponding values administered in the X.25/IP database on the NE AEQ. If administered on the EWSD enter the appropriate values. (So far in no configuration has AEQ been administered.)

LIOS 8.6 Administrator


33

Siemens IT Solutions and Services


14/06/12

Host Administration MMLCM authorization


Enter the NE user ID(s) which you want to use for MMLCM. The NE user ID(s) have to be configured on the NE by the NE administrator. For each operator group an NE user ID has to be assigned. For LIOS-internal use, there has to be assigned an NE user ID to the group none as well.

the living company

LIOS 8.6 Administrator


34

Siemens IT Solutions and Services


14/06/12

Host Administration MMLCM authorization


Entering NE user ID(s) and passwords Replay-protected password enabled. If selected, the password is encrypted to prevent replay. For the encryption, time information is used. Replay-protected password only works if the time in the LIOS system and on the NE is precisely the same this means synchronization through a radio clock or an NTP (Network Time Protocol) server is necessary. Only for EWSD V15 and higher and for hiQ V4 and higher.

the living company

LIOS 8.6 Administrator


35

Siemens IT Solutions and Services


14/06/12

Host Administration MMLCM authorization


Cyclic password change enabled. If selected, LIOS handles the problem of expiring passwords. You have to enter an initial passwords and at least three more passwords. When LIOS receives a password expired answer when accessing the NE, it automatically replaces the password with the next password in the list; when it has arrived at the last password in the list, it starts again with the first one (leaving out the initial password).

the living company

LIOS 8.6 Administrator


36

Siemens IT Solutions and Services


14/06/12

Host Administration MMLCM authorization


Here you relate LIOS operator groups to the NE user IDs. Press New. Select an operator group and relate it to an NE user ID. Do this for all LIOS groups and the internal LIOS group none. You can use the same NE user ID for all groups or different NE user IDs.

the living company

LIOS 8.6 Administrator


37

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration EFD application for EWSD (I)


The EFD application is used for creating EFDs (= event-forwarding discriminators) on the EWSD through the LIOS EFD Administration. Port number. Select which port of the Symicron card is used.

LIOS 8.6 Administrator


38

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration EFD application for EWSD (II)


Transport, Session, Presentation selector. Enter the selectors which are administered on the IP database on the NE. System title, APQ. Enter the corresponding values administered in the IP database on the NE. AEQ. If administered on the EWSD, enter the appropriate value. (So far in no configuration has AEQ been administered.)
Siemens IT Solutions and Services
14/06/12

LIOS 8.6 Administrator


39

s
the living company

Host Administration Entering password


EFD NE password. Enter here the password for the NE user ID MFKONTES (or MFKON). This NE user ID has to be created on the NE by the NE administrator. The EFD Administration uses this NE user ID when connecting to EWSD. Replay-protected password enabled . If selected, the password is encrypted to prevent replay. For the encryption, time information is used. Replay-protected password only works if the time in the LIOS system and on the NE is precisely the same this means synchronization through a radio clock or an NTP (Network Time Protocol) server is necessary. Only for EWSD V15 and higher and for hiQ V4 and higher.

LIOS 8.6 Administrator


40

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration Administering LID application for EWSD


The LID application is used for the ticket transfer from NEs to LIOS servers. Transport, Session, Presentation selectors. Enter the selectors which are administered on the IP database on the NE. System title, APQ. Enter the corresponding values administered in the IP database on the NE. AEQ. If administered on the EWSD, enter the appropriate value. (So far in no configuration has AEQ been administered.)

LIOS 8.6 Administrator


41

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration LIOS servers


Only needed for EWSD, Siemens MSC, Hi9200 The LIOS server configuration is analogue to the NE administration. For LIOS servers, the application MMLCM, LID and EFD have to be administered.

LIOS 8.6 Administrator


42

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration NE activation

After NE und LIOS server data has been administered in the Host Administration and in the the communication database of the NE, the NE can be switched to active. During activation of an EWSD, an MMLCM connection to the EWSD is made for the first time, LIOS detects the ports on the NE and subtracts their number of the LIOS license.

LIOS 8.6 Administrator


43

Siemens IT Solutions and Services


14/06/12

s
the living company

Host Administration NE activated

LIOS 8.6 Administrator


44

Siemens IT Solutions and Services


14/06/12

s
the living company

EFD Administration
EFD = event-forwarding discriminator Necessary for defining the destination to which tickets and LI NE alarms should be sent. (In most configurations the destinations are both LIOS servers.) With the EFD Administration you can manage EFDs on EWSD switches (not necessary for Alcatel S12 and Siemens Mobile).

LIOS 8.6 Administrator


45

Siemens IT Solutions and Services


14/06/12

s
the living company

EFD Administration

LIOS 8.6 Administrator


46

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating an EFD (I)


NE name. Name of target NE. Discriminator ID. It identifies the EFD on the individual NE; it must be unique only on the NE. Accepted values: 0 and positive and negative 32-bit integers (value range -2^31+1 to 2^31-1). State. Read-only field. The state of an EFD can be OK, Not in DB, Not on NE, DB != NE; Error, Undefined, Ignored and Processing. Remark. You can add a remark here. 150 characters max. Last validation. Read-only field. Date of last validation (Details form only). Creation date. Read-only field. Date of creation of EFD (Details form only). Error report. Read-only field. If an EFD Administration operation has failed, partially or as a whole, an error report is generated. The error report always refers to the last operation.

LIOS 8.6 Administrator


47

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating a new EFD (IIa)


Active destination. Read-only field. Currently valid primary address to which events are sent by the NE. Destination. (Primary) Target address to which events are forwarded. Input format: decimal numbers separated by dots (e.g. 0.2.262.1.1.4800.32.1). Backup destination. Fall-back target address for events in case the destination cannot be reached. Input format: decimal numbers separated by dots. Tickets (checkbox). If selected, LI tickets (LI records) are/will be forwarded through the EFD. NE alarms (checkbox). If selected, NE alarms (LI infos) are/will be forwarded through the EFD. Object class. Read-only field. Object IDs generated by the switch for EFDs. Name binding. Read-only field. EFD attribute. Package list. Read-only field. EFD attribute.

LIOS 8.6 Administrator


48

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating a new EFD (IIb)


Confirmed mode. If activated, user requests are confirmed by the NE after execution. Confirmed mode should always be activated. Administrative state. Read-only field. The EFD can be in the following administrative states: Unlocked: processing of the information by the discriminator is permitted by a managing system. Locked: processing of the information by the discriminator is prohibited by a managing system. Shutdown: the EFD is not operational owing to a shutdown of the NE. Operational state. Read-only field. The EFD can be in the following operational states: Disabled: the discriminator is not operational. Enabled: the discriminator is operational
Siemens IT Solutions and Services
14/06/12

LIOS 8.6 Administrator


49

s
the living company

Checking EFDs (1)


Validation can be performed - for a single EFD, - for a set of EWSDs - for all EWSDs Depending on the filter settings in the EFD administration also EFDs not used by LIOS will be displayed (e.g. EFDs used by NetManager).

LIOS 8.6 Administrator


50

Siemens IT Solutions and Services


14/06/12

s
the living company

Checking EFD (2)


After validation: If the EFD is not on the EWSD but an LI EFD, the state of this EFD will be set to Not on NE. If you want to set this EFD on the NE, just select action Align. If the EFD is on the EWSD but not in the LIOS DB, the state is set to Not in DB. If you want to take over this EFD into the LIOS DB, select take over. If the data of a specific EFD differs between the LIOS and the EWSD databases, the state of this EFD will be set to NE != DB. If you want to set the data in LIOS DB according to EWSD select Synchronize. If the EFD is not on the EWSD and not a LI EFD, it will be automatically removed from LIOS.
LIOS 8.6 Administrator
51

Siemens IT Solutions and Services


14/06/12

s
the living company

EFD manipulations
EFD 100
Validation result:

EFD state

Validate 100

EWSD 1

OK
200

Not on NE

EWSD 2 Align 200 300 Take over Synchronize Align 400 400 EWSD 4 EWSD 3

Not in DB 300
400

DB!=NE

400

LIOS
LIOS 8.6 Administrator
52

Siemens IT Solutions and Services


14/06/12

s
the living company

Setting up a new EWSD switch (I)


LIOS EWSD
Preparation of the LI functionality on the NE (LI patches, LI LTG, LI options, Q3 activated, ODAGEN, . . .) Preparation of the hardware connection from the NE to the X.25, ISDN or IP network. Preparation of the communication database on the switch (local and remote parameters).

Make sure that the communication hardware is installed (e.g. wiring, Symicron card [X.25], X.25 modem, ISDN router, IP router). Make sure that the local communication parameters of LIOS have been entered: Host Administration/LIOS servers: transport systems, transfer protocols, LIOS addresses (X.25, IP) If ISDN is used, configure a new WAN partner in the ISDN router (Bintec).
LIOS 8.6 Administrator
53

Siemens IT Solutions and Services


14/06/12

s
the living company

Setting up a new EWSD switch (II)


Host Administration/NEs: set up a new NE; enter the remote parameters for the communication with the switch. Activate the NE: In the LIOS Host Administration, NEs subapplication, select Activate NEs. Activate the new NE. BMML console: connect to the NE and set the LI passwords on the NE: enter the passwords as parameters of the MODOBSID command. Open the EFD Administration and create an EFD. (In case of inband create an EFD only for NE alarms.) From the BMML console adapt the LI options of the EWSD with the MODLIOPT command.
LIOS 8.6 Administrator
54

LIOS

EWSD

LI passwords are set. EFDs are created to make the switch divert LI tickets and alarms to LIOS. The LI options are modified.
Siemens IT Solutions and Services
14/06/12

s
the living company

LEA and CUG administration


Administration of the link to the LEA = law enforcement agency The LEA receives the call content directly from the NE through ISDN. The LEA configuration data is sent to an NE when the first observation for a LEA is created on the NE. LI tickets are sent from the NE to LIOS and then forwarded to the LEA through FTAM or FTP.

LIOS 8.6 Administrator


55

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration

LIOS 8.6 Administrator


56

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration general LEA data


LEA name. Name of LEA. Phone. Phone number for contacting the LEA in case of problems. Address. Physical address of LEA. Remark. Optional field for remarks. Default LEA. The default LEA will receive all tickets that cannot be assigned to any LEA (stray tickets).

LIOS 8.6 Administrator


57

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration observation data


Different settings have to be made for different switches. Press Next to make the settings.

LIOS 8.6 Administrator


58

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration observation data EWSD (1)


LEA ID on NEs. Read-only field. Number (generated by LIOS) by which a LEA is known to NEs. DN OF LEA. Nationally significant directory number (LAC and DN) of the LEA for the transmission of the call content DN of ticket connection. Number used in LIOS for relating tickets to LIOS. Must be unique. Overflow DN. Overflow destination for call content (optional). Length of LAC. Number of LAC digits; only for charging purposes. Version of LI tickets. Specifies the version of the LI tickets. Version of signaling. Specifies the version of signaling information in the call content connection.

LI CUG name. Name of the closed user group to which the LEA belongs (optional).

LIOS 8.6 Administrator


59

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration observation data EWSD (2)

Ticket output format. Ticket Conversion is an optional feature. Formats: Native, ASCII, ETSI V2.1 (i.e. ticket format according to ETSI Standard ES 201 671 V2.1), ETSI V2.1 with national parameters or Ticket Header V1. Transmission. Transmission of interceptrelated information (IRI) to the LEA. Q3. IRI as LI tickets through a Q3 interface sent to LIOS. INB (in-band). IRI together with the call content directly sent to LEA. ETSI HI3 encoding for EWSD V16. If the network provider has EWSD V16 switches and the call content is to be transmitted to the LEA in ETSI format, select this checkbox. HI3 encoding can only be activated in connection with Q3.

LIOS 8.6 Administrator


60

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration observation data EWSD (3)


NE ID number. The NE ID number is part of the LI tickets (defined in the Host Administration). COLP feature. The call content connection to the LEA uses the COLP feature (connected line presentation) Single connection. Transmission of the call content of A and B through the same B channel, otherwise through two separate channels. CLIP DN. A virtual number specifying the switch will be sent in the call content connection to the LEA number must be defined in the Host Administration (NE directory number).

LIOS 8.6 Administrator


61

Siemens IT Solutions and Services


14/06/12

Creating LEA Ticket transfer using FTP


Configuration of the connection from LIOS to LEA for transmitting LI tickets. Enter user ID and password. Ticket subdirectory (optional): To this directory the tickets will be written. It is a subdirectory of the home directory of the FTP user.

the living company

LIOS 8.6 Administrator


62

Siemens IT Solutions and Services


14/06/12

s
the living company

Creating LEA Transport system

TCP/IP:

LIOS 8.6 Administrator


63

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration CUG for LEAs


CUG = closed user group Can be used for protecting the ISDN calls from the NE to the LEA for transmitting the call content. To prevent LEA from being blocked by external calls. CUGs have to be preconfigured on the NE.

LIOS 8.6 Administrator


64

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration CUGs

LIOS 8.6 Administrator


65

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA Administration creating a CUG (I)


Select CUG NE type. Mandatory parameter. Select an NE type for the CUG. The CUG parameters vary depending on the NE type. CUG name. Mandatory parameter. Name of LI closed user group. The CUG name must be unique in the LIOS system. EWSD, hiQ/E9200 and MSC SR9/SR10: 15 characters max., all characters incl. special characters accepted. Alcatel S12: 8 characters max. The LI CUG name must be unique in the LIOS system. CUG index. EWSD, hiQ/E9200 and MSC SR9/SR10: Mandatory parameter. Closed user group index; 2 characters max., decimal numbers, range: 1 to 15. Whether an LI CUG index can be used, depends on the configuration of the NE. Alcatel S12: not used.

LIOS 8.6 Administrator


66

Siemens IT Solutions and Services


14/06/12

LEA Administration creating a CUG (II)

the living company

CUG interlock code. EWSD, hiQ/E9200 and MSC SR9/SR10: Mandatory parameter. Closed user group interlock code for the call content connection between the intercepting NE and the LEAs access. If no call content connection is established, this entry is without any effect. Decimal number. Range: 0 to 65535 (EWSD and hiQ/E9200); 1 to 65535 (Siemens Mobile). Alcatel S12: not used. CUG data network ID. EWSD, hiQ/E9200 and MSC SR9/SR10: Optional parameter. Closed user group data network identification code for the call content connection between the intercepting NE and the LEAs access; range: 0 to 4, decimal number. Alcatel S12: not used. Remark. Optional parameter. Maximum length: 50 characters.

LIOS 8.6 Administrator


67

Siemens IT Solutions and Services


14/06/12

LEA data managed with LEA Administration


LEA LIOS: LEA Administration LEA identification information (e.g. LEA name, postal address) Observation parameters (e.g. DN for call content, EWSD ID to be included in tickets, protection through COLP)* For Communication data for the ticket transfer tickets from LIOS to the LEA (transport system, file transfer protocol)
*) If this LEA data is modified ('Modify LEA' operation), also the corresponding LEA data on the EWSD is modified if the LEA data exists on the EWSD, that is if observations for the LEA exist.
LIOS 8.6 Administrator
68

the living company

EWSD

Sent to switch Kept on with first switch as observation long as obs. exist.

'Check LEA modification' applies only to LEA data on EWSD.


Siemens IT Solutions and Services
14/06/12

s
the living company

LEA data (I)


LIOS administrator or operator creates a LEA (LEA Administration). LIOS operator issues observation 1 for the LEA. At activation time LIOS sends CROBSGRP to the EWSD and ENTROBSCALL. LIOS operator issues observation 2 for the LEA. At activation time LIOS sends ENTROBSCALL. The LEA is created on the EWSD. Observation 1 is created on the EWSD.

LIOS

EWSD

Observation 2 is created on the EWSD.

LIOS 8.6 Administrator


69

Siemens IT Solutions and Services


14/06/12

s
the living company

LEA data (II)


At deactivation time of observation 1 LIOS sends CANOBSCALL. At deactivation time (observation 2) LIOS sends CANOBSCALL and CANOBSGRP. The LEA data is still kept in the LIOS system and can be used for future observations (until it is deleted by the LIOS administrator or operator). Observation 1 is removed. Observation 2 is removed and the LEA is removed.

EWSD

LIOS
LIOS 8.6 Administrator
70

'Check LEA modification' applies only to LEA data on EWSD.


Siemens IT Solutions and Services
14/06/12

'Modify LEA' and 'Check LEA modification'


'Modify LEA' (observation parameters affected)

the living company

LEA mod. OK LEA mod. failed

EWSD 1
observations for LEA

MODOBSGRP
'Check LEA modification' The result of the LEA modification on each EWSD is displayed on the LIOS GUI. 'Repair' (repetition of 'Modify LEA')

OK

EWSD 2
observations for LEA

EWSD 3
no obs. for LEA

EWSD 4
no obs. for LEA

LEA mod. OK LEA mod. failed

EWSD 5
observations for LEA

LIOS

MODOBSGRP

OK

EWSD 6
observations for LEA

LIOS 8.6 Administrator


71