— This work presents an experimental analysis of cylindrical copper
wire vortex generator on the fin-and-tube heat exchanger. In this study,
three different arrangement of heat exchanger are tested. In first case
the heat exchanger without wire turbulators. In second case the heat
exchanger with wire turbulators of diameter 0.2mm and third case, wire
turbulators of diameter 0.5mm diameter.
The heat transfer coefficient (h), the pressure drop of the air side,
friction factor (f) against air velocity (0.5–1 m/s) and Reynolds number
(7000–15000) have been discussed.
The wire coil is fabricated with 6mm diameter copper rod. The copper
rod is uniformly wound over the copper tube of outer diameter 9.5mm.
The pitch distance between the coil is maintained at 15mm.
After the completion of winding process the copper tube is removed
from the coil. Thus the wire coil (WC) of pitch (P) to diameter (D)
ratio, P/D=0.697 is obtained. Similar procedure is repeated to fabricate
the WC of three different P/D ratios of 0.93, 1.162 and 1.86.
An Experimental Analysis Study to Improve Performance of Tubular Heat
Exchangers
in this paper study focuses on the various experimental research analyses on performance of tubular heat exchangers
the tubular heat exchanger is used throughout various industries because of its inexpensive cost and handiness when it
comes to maintenance.
In this paper we discus about tubular heat exchanger there are several thermal design factors that are to be taken into
account when designing the tubes in the tubular heat exchangers. They are tube diameter, tube length, number of tubes,
number of baffles,& baffles inclination etc. The characteristics of flow and heat transfer within the shell are not simple.
This paper conducted various experimental analyses to predict the characteristics of difference in temperature and
pressure drop, which are the performances of heat exchanger.
Heat Transfer Enhancement in Heat Exchangers Using Turbulator
Naseema, Dr. S. Nawazish Mehdi, Iffat Naseem, S. Irfan Sadaq, Mohd Abdul Samad
A heat exchanger is a device facilitating the convective heat transfer of fluid inside the
tube. Heat transfer augmentation using twisted tape or coiled wire sometimes called
“turbulator”, are experimentally investigated in the present work. Experiments are
performed for Reynolds number ranging from laminar to turbulent. Heat transfer without
turbulator is compared with heat transfer with turbulator. The experimental results reveal
that use of turbulator leads to increase in heat transfer and friction loss over those of
without turbulator.
Project Study
Literature review
Design
# Assembly drawing + bill of material(material
selection)
# Part Drawing
# Design Calculations
# Design Verification
# Design Review
Raw material and Bought out procurement
Manufacturing
# Machining
# Inspection
# Assembly
# Testing
# Final Inspection
Validation .
Fin and tube heat exchanger comes under the category of
compact heat exchanger. Compact heat exchangers for its
compactness are measured by factor called area density. The
heat exchanger having area density greater than 700 m2/m3
comes under the category of compact heat exchanger. Car
radiators are the common application of the compact heat
exchanger.
Objective of project is to increase heat transfer rate of air
side in compact heat exchanger by using the wire
tabulators.
To compare the results for heat transfer rate for compact
heat exchanger with and without wire tabulators.
To evaluate and compare the performance parameters like
heat transfer coefficient, pressure drop, friction factor,
colburn factor of compact heat exchanger with and
without wire tabulators.
Fan
Regulator
Thermocouples
Duct with Heat exchanger
Heater
Digital Temperature Indicator
Orifice plate
U tube manometer
Fan:
Fan is used to produce airflow. Fan produce air flows
with high volume and low pressure.
Regulator:
Electric regulator is use to control the speed of the fan .By
varying the regulator we increase the mass flow rate of
bulk air and take various readings.
Thermocouples:
Thermocouples are used to sense the temperature.
Thermocouples are widely used type of temperature sensor
and can also be used as a means to convert thermal potential
difference into electric potential difference. There are variety
of thermocouples available, depending upon the applications
the particular thermocouple is selected.
Duct with Heat exchanger
Heat exchanger is used with and without the wire
turbulators.
Heater
Rod type immersion heater is used to heat the water. The
heater is used in this project to heat the water in the tank.
Q =mcp (Tc0 -Tci )= hiAi ( △Ti )m
m is the mass flow rate of cold water
Cp is the specific heat capacity of water
Tco is the hot water outlet temperature
Tci is the cold water inlet temperature
hi is the average inside heat transfer coefficient
Preheaters,
Condensers and evaporators for chemical and technical
Machine coolers
Alok Vyas, Mr. Prashant Sharma,Alok vyas et al Int. Journal of Engineering Research and Applications
www.ijera.com ISSN : 2248-9622, Vol. 3, Issue 6, Nov-Dec 2013, pp.1804-1809
Heat Transfer Enhancement in Heat Exchangers Using Turbulator Naseema*1, Dr. S. Nawazish Mehdi2, Iffat
Naseem3, S. Irfan Sadaq4, Mohd Abdul Samad5 International Journal of Engineering Research and Applications
(IJERA) ISSN: 2248-9622 (NCDATES- 09th & 10th January 2015)
Heat Transfer Enhancement in Tube-in-Tube Heat Exchanger using Passive Techniques, Parag S. Desale*,
Nilesh C. Ghuege, International Journal of Innovative Research in Advanced Engineering (IJIRAE) ISSN: 2349-
2163,Volume 1 Issue 10 (November 2014)
A Review of Research in Thermal Engineering.Study of Various Factors and Parameters Involved in Usage
of different types ofturbulators in heat exchangers