Regulator
3/2 Solenoid
Valve
HPA
Storage
Bottle
4/2 Valve
Regulator
LP Gage
Valve Body 5/2 Solenoid Valve
Note: The center
port with the brass
One Touch Fitting is
the supply or
pressure port.
Solenoid
A B
1.) Wire coil (red) is energized 3.) The valve spool (green) moves with
the iron armature
Solenoid B A
Valve Spool
EB P EA
2.) The electromagnetic field, draws the iron Springs return valve
armature (blue) into the solenoid spool to rest position
A B
5/2 Valve
5 Ports 2 Positions
EA P EB
5/3 Valve
5 Ports 3 Positions
Actuation Method EB P EA
Center Position
Pictorial Drawing of a 5/3 Valve and
Double Acting Cylinder
EB P EA
Mini Pneumatic Circuits
Pressurized Storage Bottle
Regulator
3/2
Valves
Directional valves receive signals from a control device and direct power to the
actuators. They may also provide an exhaust function while at rest. Function of the
valves must be matched to the purpose of the actuator and the job to be performed.
27
DIRECTIONAL VALVES (CONTINUED)
IDENTIFICATION OF PORTS
1 = pressure inlet port
2 and 4 = actuator ports
3 and 5 = exhaust ports
14 = piloting, control function
[connecting pressure
port (1) with
actuator port (4)]
12 = piloting, return function
[connecting pressure
port (1) with
actuator port (2)]
DIRECTIONAL VALVES (CONTINUED)
The 5/2 Directional Valve provides power to the actuator and an exhaust function as it alternates
between positions. Flow ratings for the directional valve must be chosen to accommodate the
size and desired speed of the actuator.
Here, use source port of 5/2 valve as exhaust ports.
This method use to save compressed air.
Tow flow control valve to give different speed to cylinder according to need
(selection) 32
33
Two advantages of using an air spring instead of a mechanical spring in a
cylinder are:
(2) the air spring has a constant tension throughout the entire stroke.
(3) An air spring circuit also saves in air consumption over a standard double
acting circuit.
34
Limit valve 2
Limit valve 1
36
Electric Circuit
1. Cylinder 1 Extend.
2. Cylinder 2 extend while cylinder 1 retract.
3. Cylinder 2 retract.
4. Finish operation.
37
Extend
Retract
39
Automatic retraction
Extension
40
Two Step speed Control System
High Q Low Q
41
Two Handed Safety Control system
42
Declaration Air cushion of Cylinder
46
47