I-PASOLINK

Initial setting and equipment


configuration

I-PASOLINK configuration and initial


setup
For iPasolink
1000

For iPasolink
400

10/100 Base-TX
(RJ-45)
Note; LCT Port supports
DHCP Default IP address
is 172.17.254.253

TOPC-E4011E-02-

For iPasolink
200

LCT COMMUNICATION INTERFACE

THE LOCAL CRAFT TERMINAL IS USED TO SETUP, MONITOR AND MAINTAIN iPASOLINK RADIO. iPASOLINK
SUPPLY USER GUI ENVIRONMENT THROUGH WEB BROWSER. LCT SUPPORTS BOTH LOCAL AND REMOTE
CONNECTIONS

LCT Port supports DHCP Default


IP address is 172.17.254.253

10/100 Base-TX (RJ-45)

SET THE PC INTERNET PROTOCOL,


TCP IP PROPERTIES TO OBTAIN IP
ADDRESS AUTOMATICALLY AND
OBTAIN DSN SERVER ADDRESS
AUTOMATICALLY

COMMUNICATION BETWEEN THE LCT AND THE


iPASOLINK IS VIA THE LCT PORT OF IDU
CONNECTED BY LAN CABLE.

TOPC-E4011E-02-

LCT Startup and Login

Start the browser Internet Explorer and enter the URL


http://172.17.254.253/weblct/ to open the WebLCT
Login screen.
Enter the User Name and Password in the
provided text boxes and Click Ok button
Default Username : Admin
Password: 12345678
LCT main menu opens in the Current Status screen

WebLCT LOGOUT
Always Logout using this button before
disconnecting the cable.

To Logout of the WebLCT, click on the Logout button


on the top right hand of the LCT screen.
When Logout Confirm window appears, Click Yes
LCT Login window appears
Close the Browser window to exit WebLCT.

WebLCT Initial Screen


Login User Name

Summary Alarm Indication

Opposite Site Links

Maintenance

Logout

Indicate the current


logged in user

Indicate the summary alarm of ODU, IDU,


AUX I/O, TCN, & Maintenance Status

Connect to opposite
station (s)

Maintenance ON/OFF button

Logout button

Block Diagram
Indicate the ODU,
IDU and Interfaces
mounted

Menu tree

Detail Display

Indicate the LCT Main


Menu

Display detail alarm & status information


of items selected from the Tabs

WebLCT Initial Screen


F/W Version

Site (NE) Name and IP Address

Opposite Site Links

Indicate the current


Firm Ware Version

Indicate Network element name and its


IP address

Connect to opposite
station (s)

Connecting to opposite site


Click on the opposite site links and
select the site to connect to. Login
screen for selected opposite site
open in a separate browser window

NETWORK MANAGEMENT

GENERAL SETTING
1

Select General Setting from the Network


Management Configuration Menu. NE Primary IP
Setting is displayed

2
1

Item

Parameter

IP Address Setting (Bridge 1)


IP Address
x.x.x.x
Subnet Mask
x.x.x.x
Default Gateway
x.x.x.x

Click the Setup icon, General Setting


window opens.

Enter the Primary IP address for the NE


(Bridge1), Subnet Mask, and Default
Gateway for the Bridge1. See the table
for details

Description

Input Primary IP Address of NE


Input Subnet Mask
Input Default Gateway IP
address

NMS Port Setting


Connect NMS Port to
NMS

Yes
No

Use NMS Port


Not use NMS Port

GENERAL SETTING (DETAIL) 1 of 5


2

Select General Setting


(Detail) from the Network
Management Configuration
Menu. General Setting Detail
screen opens showing the
network parameter setting

To change Network
parameters, Click the Setup
icon, General Setting
(Detail) window opens
3

After changing/ modifying


the parameters click OK
button
3

10

GENERAL SETTING (DETAIL) 2 of 5


Item

Parameter

NE2 Port Setting


NE2 Port IP
x.x.x.x
Address
NE2 Port
Used
Usage
Not Used

Description
Input IP Address of NE2 port used
for serial back-back connection
Use NE2 port
Not use NE2 port

NE2 Port
Speed

9600
specify the line speed of NE2 port2
19200
Ethernet Port Setting (NMS / NE1 Port)
Usage
Used
Use Ethernet port
Not Used
Not use Ethernet port
Auto
Negotiation

Enable
Disable

Discovery
Usage

Item

Parameter

Description

Inband Management VLAN Setting


VLAN ID
1 to 4094
VLAN ID of Inband Management VLAN
Inband management Used
Use Inband management VLAN
VLAN usage
Not Used
Not use inband management function
IP Address
Subnet mask

x.x.x.x
x.x.x.x

Used
Not Used

NE Branch Setting
Branch
1 to 4
Number
Branches
Default
x.x.x.x
Gateway
Restrict LCT Connection
LCT Port
Any
Setting
Only to
Local NE

enable the Auto Negotiation of


Ethernet port
Disable the Auto Negotiation of
Ethernet port
search of the network access
machinery using Ethernet connection
Select the Branch Number
Input the Default Gateway

Connection from Local/Remote to


LCT Port
only connection from Local to LCT
Port

Enter IP address of inband management port


enter subnet mask for inband management

11

GENERAL SETTING (DETAIL) 3 of 5

12

GENERAL SETTING (DETAIL) 4 of 5


When
When NE2
NE2 port
port is
is used
used for
for serial
serial connection
to
other
PASOLINK
configure
this NE2 Port
to other PASOLINK
Setting
Setting

Select
Select Inband
Inband Management
Management VLAN
VLAN Setting

Select
Select usage of
of NMS
NMS and
and NE1
NE1 ports
ports set
set the
the
port
parameters
accordingly
port parameters accordingly

LCT
LCT Port
Port Setting
Setting :: select
select any
any radio
radio button
button to
to connect
connect to
to remote
remote
NEs.
NEs. From
From the
the local
local LCT
LCT Port
Port
Select
Select Only
Only to
to Local
Local NE
NE radio
radio button
button to
to prevent
prevent connection
connection to
remote
NE
from
local
LCT
port.
remote NE from local LCT port.

13

GENERAL SETTING (detail) 5 of 5


Select the number of branches the NE belongs to

Enter the Bridge 2, IP address and


Subnet Mask

Select to which branch NMS port belongs to

Select to which branch Modem-2 port belongs to

14

ROUTING SETTING

15