Está en la página 1de 75

ZXG10 B8018 Hardware

Architecture

By
Mahesh K Choudhary
E-mail – maheshchoudhary@zte.com.cn
Course Objective

 Learning this course, you will be able to:


 Describe the features of ZXG10 B8018
 Outline the hardware structure of ZXG10 B8018
 Master the functions and hardware modules of
ZXG10 B8018
 Master the typical configuration of ZXG10 B8018
Contents

 Overview
 Hardware system
 Typical configurations
What does ZXG10-B8018 means?

ZXG1 0B801 8

B:macro base station hardware platform number of carriers


M:micro base statio n 8:dual carriers
range of models 0: indoor, 1: outdoor

Z X G 10 B 811 2
The Position of ZXG10-B8018 in GSM network

Centralized
Centralized OMC
OMC
Outdoor
Outdoor
BTS
BTS 900/1800M
900/1800M

HLR
HLR
BSC
BSC Q3/DB/Cobra
Q3/DB/Cobra
VAS
VAS
PCU
PCU
BTS
BTS 1900M
1900M A
A MSC GMSC
MSC GMSC

PLMN
PLMN

BSC
BSC

BTS
BTS 850/EGSM
850/EGSM
PCU
PCU SGSN
SGSN GGSN
GGSN
Gb
Gb

IP
IP Network
Network
Part A – Overview
Logical Structure

Data Modulated
Link Signal
ANTENNA
B C B Demodulated R FEEDER
PROCESSOR

S Signal RF
C M P F
Control Signal
M U signal U
System System
Clock Clock

PDU
Hardware structure

ZXG10-B8018 (V1.0)
DTRU0

MMI

Abis A Um
BSC EIB/FIB CMB DTRU1 E
Interface Interface
. M
.
PDM .
Environment
Monitor DTRU9
FCM
Power
Internal communication interface (including control
Input
signaling, data flow, clock signal and so on)
Capacity: 18 TRX/rack
Largest site type: O54 or S18/18/18
Support 6 cells
Rack structure Ability of cascades: Support 4-level cascaded
networking
Support 8 E1/T1 interface
Physical Characteristics

Grounding resistance-The case rack should be grounded well, with


grounding resistance 5 ohm at most
Technical Features
 Large system capacity and high performance
 Capacity: 18 TRX/rack
 Largest site type: O54 or S18/18/18
 Support 6 cells
 Ability of cascades: Support 4-level cascaded networking
 Support 8 E1/T1 interface
 Supports functions and channel encoding modes of
 GPRS CS1 - CS4
 EGPRS MCS1 - MCS9
 Supports the following circuit-type voice services:
 Full-rate voice service
 Enhanced full-rate voice service
 Half rate voice service
 AMR voice service
 Supports the following circuit-type data service:
 9.6 kbps full-rate data service
 4.8 kbps full-rate data service
 2.4 kbps full-rate data service
Technical Features – Continued

 Compatible with the following standards:


GSM Phase I
GSM Phase II
GSM Phase II +
 Supports modules of different frequency bands in one
cabinet.
 Supports GMSK and 8PSK modulation
 Supports automatic bridge circuit protection
 Employ Dual Transciever Unit (DTRU) technology.
 Support combined cabinet capacity expansion with ZXG10-
BTS (V2)
 Support 4-way diversity reception
 Support Tandem Free Operation (TFO)
 Provides common BCCH support, that is, same cell supports
carrier frequency of two frequency bands sharing one BCCH.
Technical Features – Continued Tandem Free Operation

T ransco din g F unctio ns

P LM N A P LM N B
Transco d in g T ran sco d in g
F u n ctio n F u nctio n
M S /U E M S /U E

C om p re ss ed S pe e ch IT U -T G .71 1 A -Laµ-Law
w/ C om pres se d S pe ec h
En co d in g D eco d in g En co d in g D eco d in g

Typical Speech Codec Tandem Operation

Tra n sco d ing F u nc tio ns B y p a ss e d

PLM N A PLM N B
T ran sc o d in g T ran sc o d in g
F u n c tio n F u n ctio n
M S /U E M S /U E

C o m p re s s e d S p e e c h
E n c o d in g D ec o d in g

Tandem Free Operation


Technical Features - Continued
 Support Dual Power Combining Transmission (DPCT)
 Support Delay Diversity Transmission (DDT)
 Advanced IP based Abis Interface
 Safe and agile power management subsystem
Technical Features – Continued

What is DPCT?
What is DDT?
What is Four Way Diversity ??
Summary -

 Reducing CAPEX
 Powerful coverage capability

 The big power output helps improve and extend the coverage area of the base station
as well as keep the number of sites to the minimum, saving the costs for main
equipment and supplementary resources.

 Net Speed technology to increase coverage and data qualities

 DDT can increase network coverage without increasing power output; improve Mobile
Station (MS) receiving sensitivity and network capacity; and reduce the costs of network
optimization.

 4-way receive diversity can be used to achieve additional uplink gain, and reduce MS
transmit power while boosting battery life. Dual Power Combining Transmission (DPCT)
is another technique to decrease CAPEX. In the initial network construction period,
DPCT can provide about 3dB transmit gain to extend the coverage area; the dual-
density TRX can be used as two TRX units to solve the capacity problem as traffic
grows.
Summary – Continued
 Powerful Abis interface transmission technologies to save transport resources

 Dynamic Abis means that time slots are dynamically mapped between the radio
channel and E1 channel at the Abis interface instead of being defined by Operation &
Maintenance Center-Radio (OMC-R), thus enabling more efficient use of Abis time
slots when packet-based services continue to grow.
 Abis compression technology can achieve an industrial leading 15:1 compression
ratio, which means one E1 supports 15 TRXs transfers in the Abis interface. (*ring)
 Abis over IP enables operators to use IP networks to connect the BSC and BTSs,
thereby saving on transport facility and reducing CAPEX. This technique also
supports capacity expansion as IP networks offer high bandwidth.
 If 4-way receive diversity is performed in conjunction with either the DPCT or DDT
technique, a BTS can provide ultra-far coverage area.
Summary – Continued
 Reducing OPEX
 Lower power consumption and OPEX
For operators, power consumption reduction in base stations is an increasingly important
consideration as it means lowered cost, smaller heat dissipation and improved reliability.
With no air conditioning necessary and lower power consumption, the ZXG10 8000 series
BTSs can decrease site OPEX to new levels.

 Small size and light weight, allowing easy installation


Intelligent BTS shutdown

 Under low traffic conditions, some TRX units can be shut down to save on power
consumption costs. The BTS will detect the power supply, and some TRX units will be
closed to extend battery service run time when the remaining battery power is lower than the
preset value.
 Universal TRX module and control board
DTRU, main control and channel processing modules can be used in both indoor and
outdoor BTSs. These universal modules help lower the expenses for spare parts, as well as
the maintenance and networking costs.
Cabinet TOP

1: PE 9: E1 PORT 17:
HYCOM6
2: PWRTA_L1 10: RELAY_ALM 18:
HYCOM7
3: PWRTA_L2 11: ID PORT 19:
HYCOM8
4: PWRTA_L3 12: HYCOM1 20:
HYCOM9
5: 13 MHz Clock 13: HYCOM2 21:
HYCOM10
6: FCLK 14: HYCOM3 22:
HYCOM11
7: RJ45 15: HYCOM4 23:
HYCOM12
ID Switch

15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0

 SATE
 Whether to use the
SLAVE 1_ SLAVE 2_
BTS _TYPE BTS _NO
PORT PORT
SATE ABIS _PORT ABIS _TS satellite Abis link or
not
 0: Common Abis
 SLAVE1_PORT  1: Satellite Abis
 BTS_TYPE  The E1 port of the basic  ABIS_PORT
 1100: B8018 cabinet to connect extended
cabinet 1
 O&M port number
 1101: B8112
 00: Port E of the basic
 00: Port A
 1110: M8202  01: Port B
cabinet
 1111: M8204
 01: Port F of the basic  10: Port C
 BTS_NO
cabinet  11: Port D
 No. of the cabinet of  10: Port G of the basic  ABIS_TS
the same site
cabinet  The O&M LAPD
 00: Basic cabinet  11: Port H of the basic timeslot on the Abis
 01: Extended cabinet interface
cabinet 1  SLAVE2_PORT  000: TS16
 10: Extended The E1 port of the basic
  001: TS31
cabinet 2 cabinet to connect extended  010: TS30
cabinet 2  011: TS29
 00: Port E of the basic  100: TS28
cabinet
 101: TS27
 01: Port F of the basic
cabinet
 110: TS26
 10: Port G of the basic
 111: TS25
cabinet
 11: Port H of the basic
cabinet
Internal Circuit Connections

Power PDM
-48 V
Input
Control 8 M HW , clock
控制框
Frame Site IDID
DIDB 站点 and intellegent
power ON / OFF
ABIS Interface ( 8 line 8 8 E路E
1 /1/TT 1
1
E 1 /T 1 or one 100
Mbps Ethernet ) EIB / FIB 8 MHW
Only applied on FIB CMB
Synchronization
clock I /O Power and interface control ( TDM Switching )
Monitor interface
LMT serial 、interface , network interface
FCLK and 13 M Hz test clock

Fan
风机 3
3 DFCM
DFCM working power and alarm collection
Transceiver
Antenna frame 3
Feeder

DTRU1
DTRU0

DTRU2

AEM1

AEM2
AEM0

AEM 0 alarm + 12 V /- 12 V
AEM 1 alarm AEM 2 alarm

Fan
风机 3
3 DFCM

DFCM working power and alarm collection


Transceiver
frame 2
Antenn a
F eed er

DTRU1

DTRU2
DTRU0

AEM1

AE M2
AEM0

AEM 0 alarm + 12 V /- 12 V
AEM 1 alarm AEM 2 alarm

Fan
风机 3
3 DFCM

DFCM working power and alarm collection


Transceiver
frame 1
Antenna
Feeder

D TRU1

DTRU2
DTRU0

A EM2
AEM1
AEM0

AEM 0 alarm + 12 V / - 12 V
AEM 1 alarm AEM 2 alarm
Part B - Software structure
 dCMM
 system power-on initialization
 downloads all board software
 operation, maintenance and
management
dCMM dFUC dCHP
 dFUC and dCHP
 service processing
FIU
 baseband signal processing Abis
dTRX

 FIU BTS B8018 Software System

 connection with BSC


 working flow control
 resource configuration
management
Software Structure – Introduction

Figure 24 Software architecture


of ZXG10 B8018
www.zte.com.cn
dCMM Software

Configuration Software Loading

Alarm Switching

Status
MMI
Management

dCMM Software Sub-system


dFCU Software

Alarm collection and report of dTRM unit

Support power control of MS and BTS Operation and Radio Resource


操作维护
Maintenance 无线资源管理
Management
Calculates TA
版本控制
Version Control 功率控制
Power Control

Equipment Paging and Access


设备管理
Management 寻呼与接入管理
Management

DFUC
dFUC 软件子系统
Software Sub-system
FIU Software

MAC address translation


table configuration
management

Bidirectional 8MHW to dCMM


translation from
IP Input MAC packet to E 1

FIU S oftware Sub -system


Part C –Board /Panel Functioning
CMB Function
 Provides eight E1/T1 interfaces.
 Implements switching of thirty-two 2 M HW time slots with 2 bit
switching array.
 Provides transparent passage for external environment alarm.
 Provides all kinds of clock needed in BTS; including clock
signal of 13 MHz, 2.048 MHz, 60 ms, 8K_8MW, 8 MHz, 16
MHz and so on.
 Detects, controls, and maintains the whole BTS system,
support near-end and far-end management interface.
 Monitoring and control of each board running status
 Board provides active/standby switching
CMB Functional Structure
CMB Panel LED Indicators
LED Color Name Meaning Working Mode
1 Green/Red PWR Power LED 1. Green ON: Normal
2. Red ON: Alarm
3. OFF: Power off or other reasons
2 Green RUN Running LED 1. Green flashing at 4 Hz: Boot is running
2. Green flash at 1 Hz: Application is running
3. Others: System is abnormal
3 Green/Red SYN Clock synchronization 1. Green ON: Synchronization clock of the Abis
mode LED interface network
2. Green flashing at 1 Hz: Synchronization clock of
the SDH network
3. Red flashing at 1 Hz: E1 frame out-of-sync alarm
4. Red ON: E1 line is broken or not connected
5. OFF: Free running

4 Green/Red CLK Clock LED 1. Green ON: Network synchronization is locked


2. Green flashing at 1 Hz: Locking the phase
3. Red ON: Clock fault
5 Green MST Active/Standby LED 1. Green ON: Active state
2. Green OFF: Standby state
6 Green/Red STA Status LED 1. OFF: Running normally
2. Green flashing at 1 Hz: System initialization
(Low).
3. Green flashing at 4 Hz: software loading
4. Red flashing at 1 Hz: LAPD link disconnection
(High).
5. Red flashing at 4 Hz: HDLC link disconnection
(Low).
6. Red ON: Other alarms (such as temperature, clock
and frame number alarms)
EIB Functions

 Provide line impedance matching of 8 E1/T1


 Signal isolation at IC side and line side
 Line protection at E1/T1 line interface
 Bypass function of E1/T1 line.
 Provides type information of interface board to CMU
Bridge




Connection Relay
Protection



Device
EIB
8 E1/T1



Transformer




Matching Circuit
Backplane
EIB Panel Structure

EIB
Function of PDM

 PDM distributes the -48 V power to CMBs, DTRUs and FCMs, and
provides overload protection via circuit breakers. In addition to a circuit
breaker for each module, a main switch circuit breaker is placed at the -48
V input end on the top of the BTS cabinet.

Function Structure of PDM

TRM /ETRM 1
. 12
Circuit
PWR breaker Filter . TRMs /
. ETRMs
- TRM /ETRM 12
48 V
CMM 1
2 CMMs
CMM 2
PWRGND

-48 VGND
dTRU Functions

 Processes 2 carriers at maximum in downlink:


 Complete rate adaptation
 Channel coding and interleaving
 Encryption
 Generating TDMA burst pulse
 Complement GMSK/8PSK modulation
 Digital up-conversion of the two carriers
 Processes 2 carriers at maximum in uplink:
 Implement uplink digital down conversion
 Diversity combining of receiver
 Digital demodulation (GMSK and 8PSK demodulation, equalization)
 Decrypting
 De-interleaving
 Rate adaptation
dTRU Functions - Continued

 Implement processing of uplink and downlink RF signal.


 Receive switching signal of CMB to complete power ON/OFF of module.
 Support online update and load of software version, support version update
of programmable device.
 Detect working state of module, collect alarm signal in real time and report it
to CMB.
 Support RF frequency hopping, DPCT, downlink transmission diversity, and
four diversities reception in
dTRU Panel LED Indicators
Identifier Meaning

RXM1 Receiver 1
DTRUG
RXD1 Receiver 1 (for diversity)
TX1

RXM1
TXcom RXM2 Receiver 2

RXD1
RXD2 Receiver 2 (for diversity)

TX1 Transmitter 1

TX2 Transmitter 2
TX2
PWR
TXcom Transmitter Combiner
RUN

MOD
RXM2 ETP Extend Test Port
ACT1
RXD2
ACT2

STA Identifier Full Name Meaning


RST

PWR Power Power LED

RUN Run Running LED

MOD Model BCCH mode LED

ACT1 Active Channel activation LED1


ETP

ACT2 Active Channel activation LED2

STA State Status LED

RST Reset Reset button


Modules for Different Frequency Range
Functions of AEM

 Combines the transmit signals of multiple carriers.


 Provides bidirectional signal channels from the BTS to the
antenna for the transmitting band and from the antenna to the
BTS for the receiving band.
 Gives an alarm when the VSWR of the antenna port
deteriorates.
 Suppresses the interference out of the working band and
spurious emission.
 Flexibly configures carriers.
 Implements diversity receiving.
CDU Panel LED indicators

LED Position Color Name Meaning Working Mode

1 Green FPO Forward power ON: Normal


output LED OFF: Abnormal
2 Red SWR1 VSWR level-1 alarm ON: There is an alarm
LED OFF: There is no alarm

3 Red SWR2 VSWR level-2 alarm ON: There is an alarm


LED OFF: There is no alarm

4 Green PWR LNA power supply ON: Normal


LED OFF: Abnormal
5 Red LNA LNA alarm LED ON: There is an alarm
OFF: There is no alarm
CDU Functional

LNA_Splitter ERX1 (v.v.i)


ERX2
Duplexer
Cable Rx_in RX1
ANT RX2

RX3
Cable
RX4

Alarms
RTE
forward reverse
optional Tx_out
TX1
VSWR_meter
50ohm TX2
Hybird_combiner
Alarms
CDU Functional Structure

Identifier Full Name Meaning

ETX Extended TX Extended TX port


RTE Radio Test Equipment Radio test port
TX1 Transmitter 1 Combiner input 1 (PA output signal)
TX2 Transmitter 2 Combiner input 2 (PA output signal)
RX1 Receiver 1 Low noise amplifier output port 1
RX2 Receiver 2 Low noise amplifier output port 2
RX3 Receiver 3 Low noise amplifier output port 3
RX4 Receiver 4 Low noise amplifier output port 4
ERX1 Extend Receiver 1 Low noise amplifier extended output port 1

ERX2 Extend Receiver 2 Low noise amplifier extended output port 2

ANT Antenna Antenna feeder port


Panel LED Indicators of ECDU

LED Color Name Meaning Working Mode

1 Green FPO Forward power output ON: Normal


LED OFF: Abnormal
2 Red SWR1 VSWR level-1 alarm ON: There is an alarm
LED OFF: There is no alarm
3 Red SWR2 VSWR level-2 alarm ON: There is an alarm
LED OFF: There is no alarm
4 Green PWR LNA power supply LED ON: Normal
OFF: Abnormal
5 Red LNA1 Channel 1 LNA alarm ON: There is an alarm
OFF: There is no alarm
6 Red LNA2 Channel 2 LNA alarm ON: There is an alarm
OFF: There is no alarm
Functional structure of ECDU

Identification Full Name Meaning


Symbol
RTE Radio Test Equipment Radio test port

RX1 Receiver 1 Low-noise amplifier output


port 1
RX2 Receiver 2 Low-noise amplifier output
port 2
RXD1 Receiver for Low-noise amplifier output
Diversity1 port 1 (diversity)

RXD2 Receiver for Low-noise amplifier output


Diversity2 port 2 (diversity)

ANT Antenna Antenna feeder port


ANTD Antenna for Diversity Antenna feeder port
(diversity)
CEU Functional Structure

Identifier Meaning Description

OTX1 Output TX 1 Combiner TX output port 1


OTX2 Output TX 2 Combiner TX output port 2
TX1 Transmitter 1 Combiner input 1 (PA output signal)
TX2 Transmitter 2 Combiner input 2 (PA output signal)
TX3 Transmitter 3 Combiner input 3 (PA output signal)
TX4 Transmitter 4 Combiner input 4 (PA output signal)
RX1 Receiver 1 Splitter output port 1
RX2 Receiver 2 Splitter output port 2
RX3 Receiver 3 Splitter output port 3
RX4 Receiver 4 Splitter output port 4
ERX1 Extend Receiver 1 Splitter input port 1 (low noise amplifier
extended output)
ERX2 Extend Receiver 2 Splitter input port 2 (low noise amplifier
extended output)
CEU and CEU/2 panel

CEUG/2

OTX1

ERX1

TX1

RX1

TX2

RX2

ERX2

OTX2

RX3

TX3

RX4

TX4

CEU CEU/2
CEU Functions

Identifier Meaning Description

OTX1 Output TX 1 Combiner TX output port 1

OTX2 Output TX 2 Combiner TX output port 2

TX1 Transmitter 1 Combiner input 1 (PA output signal)

TX2 Transmitter 2 Combiner input 2 (PA output signal)

TX3 Transmitter 3 Combiner input 3 (PA output signal)

TX4 Transmitter 4 Combiner input 4 (PA output signal)

RX1 Receiver 1 Splitter output port 1

RX2 Receiver 2 Splitter output port 2

RX3 Receiver 3 Splitter output port 3

RX4 Receiver 4 Splitter output port 4

ERX1 Extend Receiver 1 Splitter input port 1 (low noise amplifier extended
output)

ERX2 Extend Receiver 2 Splitter input port 2 (low noise amplifier extended
output)
CENU and CENU/3 panel

CENUG/3

RX1
OTX1

RX2

ERX1 TX1

RX3

RX4 TX2

TX3

RX5 OTX2

RX6

TX4
ERX2

RX7

TX5
RX8

TX6

CENU CENU/3
Structure of CENU and CENU/3
CENU/2 and CENU/4 panel

CENUG/2 CENUG/4

OTX1 OTX1
ERX1 ERX1

RX1 RX1
TX1 TX1

TX2 TX2
RX2 RX2

TX3 TX3

ERX2 ERX2
OTX2 OTX2

RX3 RX3

TX4 TX4

RX4 TX5 RX4 TX5

TX6 TX6

CENU/2 CENU/4
Structure of CENU/2 and CENU/4
Part D – Typical Configuration
Star

SITE 0

B SITE 1
S .
C .
.

SITEn

Since the signal transmission is through fewer


intermediate links
Along the path, the reliability of transmissions is
higher.

Deployed in densely populated areas


Chain

BSC S IT E0 S IT E1 S IT E2

Applicable to one site multi BTS situations

Since the signals goes through more links, the line


reliability is relatively poor than star networking
Tree

SITE 1

SITE 0
SITE 2
B
S
C

SITE n

ne reliability is relatively low,the fault from the upper levelsite can


Affect the proper running of the lower level site

ostly deployed in large areas with less population


Ring

BSC

S IT E0 S IT E1

S IT E2 S IT E3

Each line denotes a bidirectional E1 connection. The DIP switches


Settings of BTS should be according to the background configurations

 All the nodes are connected in closed loop, it can span larger distances
then other types of networks. The reliability is higher; as it strays connect with the
BSC through the other end, if the link is broken from one place.

 It can deployed in suburb and rural places


AEM Position

 The marked positions EIB


PDM CMB
for CMB
FCM
 CEU/2
A D D D A A
 CENU/3 E T T T E E
M R R R M M
 CENU/4 U U U
FCM

A D D D A A
E T T T E E
M R R R M M
U U U
FCM

A D D D A A
E T T T E E
M R R R M M
U U U
Part E – Site Configuration
 Four-way diversity
 Using ECDUs
O1 configuration

 Two-way diversity
 Using CDUs
O1 Implementation – Boards

TMA

TMA
CDU DTRU CDU
TX1

ETX1 RXM1 ETX1


TX1 TX-COM TX1
RXD1

RTE TX2 TX2 RTE TX2

RXM2

ANT RXD2 ANT


RX1 RX1

RX2 RX2

RX3 RX3

RX4 RX4

ERX1 ERX1

ERX2 ERX2
O2 Implementation Through Combiner

TX/RX TX/ RX

ANT CDU ANT


CDU

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1 TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2

DTRU
O2 Configuration -Board

CDU DTRU CDU


TX1

ETX1 RXM1 ETX1

TX1 TX- COM TX 1


RXD1

TX2 TX2 TX 2
RTE RTE

RXM2

ANT RXD2 ANT


RX1 RX1

RX2 RX2

RX3 RX3

RX4 RX4

ERX1 ERX1

ERX2 ERX2
O2 Implementation Not Through Combiner

TX/RX TX/RX

TMA TMA

ANT ANT
CDU CDU

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1 TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2

DTRU
O2 Configuration - Not Through Combiner

T MA
TMA CDU DTRU CDU
TX1

ETX1 RXM1 ETX1


TX1 TX- COM TX1
RXD1

TX2 TX2 TX2


RTE RTE

RXM2

ANT RXD2 ANT


RX1 RX1

RX2 RX2

RX3 RX3

RX4 RX4

ERX1 ERX1

ERX2 ERX2
O4 Configurations

TX/RX TX/RX

CDU DTRU DTRU CDU


TX1 TX1

ETX1 RXM1 RXM 1 ETX1


ANT ANT
TX1 TX-COM TX-COM TX1
CDU CDU
RXD1 RXD1

RTE
TX2 TX2 TX2
RTE
TX2
TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1 TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1
RXM2 RXM2

ANT RXD2 RXD2 ANT


RX1 RX1

RX2 RX 2

RX 3 RX3

RX4 RX4

ERX1 ERX1
TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2 TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2
ERX2 ERX2
DTRU DTRU
O4 Configuration

TX/RX TX/RX

ANT ANT
CDU CDU

TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1 TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX2 ERX1

TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2 TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2

DTRU DTRU
O4 Configuration –Board Implementation

CDU DTRU DTRU CDU


TX1 TX1

ETX
1 RXM
1 RXM
1 ETX1
TX1 TX- COM TX- COM TX1
RXD
1 RXD
1

TX2 TX2 TX2 TX2


RTE RTE

RXM
2 RXM
2

ANT RXD
2 RXD
2 ANT
RX1 RX1

RX2 RX2

RX3 RX3

RX4 RX4

ERX
1 ERX
1

ERX
2 ERX
2
O6 Configuration Using CEU/2

TX/RX TX/RX

ANT ANT
CDU CDU

CDU DTRU DTRU DTRU CEU/2 CDU TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2 TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2
ERX1
TX1 TX1 TX1
OTX1
ETX1 RXM1 RXM1 RXM1 ETX1
TX- COM TX- COM TX- COM TX1
TX1 TX1
RXD1 RXD1 RXD1 RX1
OTX1 OTX2 ERX1 ERX2
TX2
TX2 CEU/2
TX2 TX2 TX2 RX2 TX2
RTE RTE
TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4
RXM2 RXM2 RXM2

ANT RXD2 RXD2 RXD2 ANT TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2
RX1
ERX2 RX1
OTX2 DTRU
RX2 RX2

RX3 TX3 RX3

RX4
RX3 RX4
TX4
ERX1 RX4 ERX1
TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2 TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2
ERX2 ERX2
DTRU DTRU
O6 Configuration Using CENU/4

TX/RX TX/RX

ANT ANT
CDU DTRU DTRU DTRU CENU/4 CDU
CDU CDU
ERX1 TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2 TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2
TX1 TX1 TX1 OTX1
ETX1 RXM1 RXM1 RXM1 ETX1
TX- COM TX- COM TX- COM TX1
TX1 TX1
RXD1 RXD1 RXD1 RX1 OTX1 OTX2 ERX1 ERX2
CENU/4

TX2
TX2 TX1 TX2 TX3 TX4 TX5 TX6 RX1 RX2 RX3 RX4
TX2 TX2 TX2 RX2 TX2
RTE RTE

TX3 TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2


RXM2 RXM2 RXM2
DTRU
ANT RXD2 RXD2 RXD2 ANT
RX1 ERX2 RX1
OTX2
RX2 RX2
TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2 TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2
RX3 TX4 RX3 DTRU DTRU

RX4
RX3 RX4
TX5
ERX1 ERX1
RX4
ERX2 TX6 ERX2
O8 Configuration

TX/RX TX/RX

CDU DTRU DTRU DTRU CEU/2 CDU


ERX1
TX1 TX1 TX1
OTX1
ETX1 RXM 1 RXM 1 RXM1 ETX1
TX-COM TX-COM TX-COM TX1
TX1 TX1
RXD1 RXD1 RXD1 RX1
TX2 ANT ANT
RTE
TX2 TX2 TX2 TX2
RX2 RTE
TX2
CDU CDU
RXM2 RXM2 RXM2
TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2 TX1 TX2 ETX RX1 RX2 RX3 RX4 ERX1 ERX2
ANT RXD2 RXD2 RXD2 ANT
RX1 ERX2 RX1
OTX2
RX2 RX2

RX3 TX4 RX3

RX4
RX3 RX4
TX5
ERX1 ERX1
RX4 OTX1 OTX2 CEU ERX1 ERX2 OTX1 OTX2 CEU ERX1 ERX2
ERX2 ERX2

TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4 TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4

CEU DTRU
ERX1
OTX1 TX1

RXM1
TX1 TX-COM
RX1 RXD1
TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2 TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2
TX2 TX2
RX2
DTRU DTRU
RXM2

RXD2
ERX2
OTX2

TX4
TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2 TX1 TX2 TXCOM RXM1 RXD1 RXM2 RXD2
RX3
TX5
RX4
DTRU DTRU
TX/RX TX/RX

RX1 RX1
CDU RX2
RX3
RX2
RX3 CDU
TX1 TX2 ERX1 ERX2 RX4 RX4 TX1 TX2 ERX1 ERX2

O8 OTX1 OTX1
CEU
EX1

TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4


EX2 OTX1 OTX1
CEU
EX1

TX1 TX2 TX3 TX4 RX1 RX2 RX3 RX4


EX2

TX RX RXD TX RX RXD TX RX RXD TX RX RXD


TRM1 TRM2 TRM5 TRM6

TX RX RXD TX RX RXD TX RX RXD TX RX RXD


TRM3 TRM4 TRM7 TRM8
Table: ZXG10 B8018 (V1.00) voltage and power consumption

Characteristics
Parameters Values

Voltage Required working 48 V DC


voltage
Range 40 V DC (Minimum)

57 V DC (Maximum)

Power Consumption TRM (×18) 160 W per TRM


(fully configured:
3400 W for 40W) ETRM 175 W per ETRM

CMM (×2) 16 W per CMM

AEM (×9) 5 W per AEM

Fan (×3) 60 W per Fan

Power consumption 3750 W (60W)


Heat Dissipation

Parameters Values
Characteristics

TRM (×18) 120 W per TRM

ETRM 135 W per ETRM

AEM (×9) 45 W per AEM

CMM (×2) 20 W per CMM

Fan (×3) 30 W per Fan


Table: ZXG10 B8018 (V1.00) Reliability Specification

Characteristics
Values
Mean Time Between Failures 6.3×10000 hours(7 Yrs)
(MTBF)

Mean Time to Repair (MTTR) 34 min. 12 sec.

Availability Ratio (A) 99.9991 %

Average Interruption time per year 4 min. 48 sec.

The product successfully passed the CE certification. It complies with international standards
related to personal safety, electromagnetic security (EMC) and wireless frequency spectrum.
RF Indices

 Output power-ZXG10 8018 supports 40W power for 8PSK and 60W for GMSK
 Static sensitivity-the static receiving sensitivity of ZXG10 8018 reaches up to -112
dbm. The high sensitivity guarantees the uplink channel performance and is one of
the prerequisites for a wide coverage
Working Modes
Work Mode Description

Dual carrier mode No Four-way diversity configuration, no DPCT setting


configuration. DTRU can configure both the left and the
right sub boards.

Odd carrier modes Odd carrier with 4-way diversity Only configure Four-way diversity. DTRU only configures the left
reception sub board, and the right sub board has no data
configuration.

Odd carrier with 4-way diversity Four-way diversity plus DPCT. DTRU only configures the left
reception and DPCT sub boards, and the right sub board has no data
configuration.

Odd carrier No Four-way diversity, no DPCT setting. DTRU only configures


the left sub board, and the right sub board has no data
configuration.

IRC

IRC User can check or uncheck IRC Interference Resistance Combination


check box depending on
actual configuration.

También podría gustarte