Está en la página 1de 12

PMR IMPLEMENTATION

ACCESS - PMR Implementation


1. Antenna System Checking c/o SNC

Determine condition of TX/RX antenna & feeder cable through sweep testing.

VSWR value = 1.5


Antenna Mechanical Tilt = from audit data Antenna Orientation = from audit data

2. BTS Health Check (re-commissioning) c/o SNC

TRX loop testing Diversity testing Other PIU testing (Duplexer, Multi-coupler, combiner cooling fan etc.) Checking of loose connector & cabling

PMR IMPLEMENTATION
ACCESS - PMR Implementation
3. Basic Parameter checking through CDD c/o SNC, NSA & Access

TRX Frequency MBCCH/TCH Hopping Parameter MAL list GTRX GENA EGENA CDED CDEF ADCE

PMR IMPLEMENTATION
ACCESS - PMR Implementation
BTS KPI

PMR IMPLEMENTATION
ACCESS BSC - PMR Implementation
BSC OVERLOAD PROTECTION:

0.4 Signalling link load 80% Ater Utilization (average) 80% TRX Utilization (average) 80% CPU Load (average) 90% Gb link load (average)

BTS REHOMING CONSIDERATION:


Ater utilization of target BSC < 80% Paging load of target BSC < 150000 pages (assuming 1 LAC per BSC) Signaling link load of target BSC < 0.4 CPU load of target BSC < 80% Gb link load of target BSC < 90% Gb link license (GPRS/EDGE) must be updated VLR of target homing MSC < 85%

PMR IMPLEMENTATION
BSC Health Check c/o BSS Opti

Printing of Alarm History (for the past 24 hrs) Printing of Current Alarms Checking working states of PIUs Checking of TRX Channel Interrogate Circuit Checking of Signaling Checking of Network Configuration Unit diagnostics and HW Switchover

PMR IMPLEMENTATION
ACCESS BSC - PMR Implementation
BSC2i Traffic Handling Capacity:

BSC2i configured with 512 full rate TRXs, circuit switched: 512 TRXs (64 TRX per BCSU) 248 BCFs (31 BCFs per BCSU) 512 BTSs (64 BTSs per BCSU) 6144 SDCCHs (768 SDCCHs per BCSU) 4096 TCHs (512 TCHs per BCSU) 3040 Erlangs total traffic handling capacity (max of 26 aters) 2 x 128 kbps (max signaling link per bcsu)

PMR IMPLEMENTATION
ACCESS BSC - PMR Implementation
BSC3i Traffic Handling Capacity:

BSC3i is configured with 660 full rate TRXs, circuit switched: 660 TRXs (110 TRX per BCSU) 660 BCFs (110 BCFs per BCSU) 660 BTSs (110 BTSs per BCSU) 10560 SDCCHs (1760 SDCCHs per BCSU) 5280 TCHs (880 TCHs per BCSU) 3920 Erlangs total traffic handling capacity (max of 33 aters) 2 x 256 kbps (max signaling link per bcsu)