OptiX BWS 1600G Optical power Calculation

Prithvi Information Solution Ltd.

Objectives
Upon completion of this course, you will be able to :-

Grasp the Optical Power Calculation. Grasp the common indices on Optical Power Calculation. Grasp the relation of each Reference Point on the Equipments.

Prithvi Information Solution Ltd.

Chapter 1 Common Terms Used Chapter 2 Power Calculation of OSC Chapter 3 Power Calculation Traffic Channel

Prithvi Information Solution Ltd.

Common Terms

Insertion Loss Gain Receiver Sensitivity Overload power

Prithvi Information Solution Ltd.

Insertion loss

Insertion loss is the decrease in transmitted signal power resulting from the insertion of a device in a transmission line or optical fiber. It is usually expressed relative to the signal power delivered to that same part before insertion. Insertion loss is usually expressed in decibels (dB). Insertion loss=Pin /Pout In an optical fiber system, insertion loss is introduced by things such as connectors, splices, and coupler

Prithvi Information Solution Ltd.

Receiver Sensitivity

Sensitivity in a receiver is normally taken as the minimum input signal (Smin) required to produce a specified output signal.
For example
A receive sensitivity of -78 dBm is better than a receive sensitivity of -75 dBm by 3 dB, or a factor of two. In other words, at a specified data rate, a receiver with a -78 dBm sensitivity can hear signals that are half as weak as a receiver with a -75 dBm receive sensitivity.

Prithvi Information Solution Ltd.

Overload Power

Overload power of a receiver module may be defined as Maximum power with which a card can be withstand and work with its full functionality.

Prithvi Information Solution Ltd.

Specification of Optical Amplifier


Types of OA Total Input Power (dBm) -32 ~ -8 OPU Single Channel Input Power (dBm) -24 23 Gain(dB)

OAU

-32 ~ -4

-20

20 ~ 31

OBU03

-24~ -3

-19

21 ~ 25

Prithvi Information Solution Ltd.

Specification of OTU
OTU Types Receiver Sensitivity (dBm) -18 -14 -18 -28 -18 -12.6 -18 -19 -18 < -28 -18 < -21 Overload power (dBm) -9 -1 -9 -9 -9 0.5 -9 -3 -9 -9 -9 -3 Mean launch Power (dBm) +1 ~ -5 +2 ~ -1 +1 ~ -5 +3 ~ -2 +1 ~ -5 +0.5 ~ -8.2 +1 ~ -5 -3 ~ -11 +1 ~ -5 -2 ~+3 +1 ~ -5 +5 ~ -2

LWF

DWDM Side Client Side

TMX

DWDM Side Client Side

LWF(WAN)

DWDM Side Client Side

LOG

DWDM Side Client Side

LWC1

DWDM Side Client Side

FDGS

DWDM Side Client Side

Insertion loss of M40 in dB is 2 to7 Insertion loss of D40 dB is 2 to 7 Insertion loss of FIU in dB is 1

OPTICAL TERMINAL MULTIPLEXER CONNECTION DIAGRAM (10G)

Prithvi Information Solution Ltd.

POWER CALCULATION STEPS AT OTM


1. 2.

Figure in previous slide shows the fiber connection on OTM. Check if the fiber connection between boards is correct based on the fiber connection diagram and if the fiber on each board is well inserted. If not, correct the error immediately. Make the client sides of all OTUs access signals in either of the following two ways: The OTU optical power commissioning requirements that the input optical power of the client-side RX should be within the Dynamic range If the measured input optical power of the RX is not within Dynamic range than attenuation by fixed attenuators can be added to meet the specified optical power .

3.

4.

Prithvi Information Solution Ltd.

POWER CALCULATION STEPS AT OTM


6.

Test the output optical power of the OUT interface on the OTU. The value should be within the range from +1 dBm to 5 dBm and is 2 dBm normally. Test the receiving optical power of the Mn interface of the M40 and record the value. Standard per-channel input power = Maximum input optical power 10lgN, where N is the maximum number of wavelengths. Now we have to set the input power for through manual VOA provided at the input of OBU as -3dBm ( For 40ch.). Attenuation of the variable attenuator = Input optical power of the IN interface on the OBU Output optical power of the OUT interface on the M40.

7.

8.

9.

10.

Prithvi Information Solution Ltd.

POWER CALCULATION STEPS AT OTM

13.

On the other end the input for OPU is adjusted through EMS/LCT with electronic VOA provided at the input of OPU as -8(For 40CH) RC-OUT insertion loss on the FIU = Input optical power of the RC on the FIU Optical power of the OUT on the FIU Test the optical power of the OUT interface on the FIU when RM is disconnected. For the insertion loss requirement, refer to the OptiX BWS 1600G Backbone DWDM Optical Transmission System Technical Description. Test the optical power of the TM interface on the SC1 and the RM interface on the FIU, and calculate the RM-OUT insertion loss. RM-OUT insertion loss on the FIU = Optical power of the RM on the FIU Optical power of the OUT on the FIU (disconnect RC interface)

14.

15.

16.

17.

Prithvi Information Solution Ltd.

POWER CALCULATION STEPS AT OADM SITE(10G)

Prithvi Information Solution Ltd.

POWER CALCULATION STEPS AT OADM SITE(10G)


1.

Figure on previous slide shows the fiber connection on OADM site. Check if the fiber connection between boards is correct based on the fiber connection diagram and if the fiber on each board is well inserted. If not, correct the error immediately. Perform the commissioning on the west OPU by setting the attenuation with help of electronic VOA provided at the input of OPU through LCT/EMS for specified power levels ( -8 dBm for 40ch.dBm) Test the receiving optical power of the IN interfaces of all west OTUs respectively and record all the values. Connect the optical power meter to the IN interface of the OTU with the largest optical power.
Prithvi Information Solution Ltd.

2.

3.

4.

5.

POWER CALCULATION STEPS AT OADM SITE(10G)


6. After the commissioning of the west receiving optical amplifier is complete, adjust the manual variable attenuator(A-11) between the west OPU and the MR2. Make the input optical power of the IN interface on the west OTU that has the highest receiving optical power reach 6 dBm, to ensure that the input optical power of the IN interfaces on all the west OTUs is within the range from 6 dBm to 8 dBm. 7. Test the optical power of the IN interface on the first west D40and calculate the insertion loss of the attenuator. 8. Insertion loss of the attenuator = Output optical power of the receiving optical amplifier OPU Input optical power of the IN interface on the D40. 9. Repeat Steps 3 to 6 to complete the commissioning on the second west D40 .
Prithvi Information Solution Ltd.

POWER CALCULATION STEPS AT OADM SITE(10G)


10. Use a Power meter to test the input optical power of the east OBU. Adjust the variable attenuator between the west MR2 and the east MR2(A-9), to make the average input optical power of the OBU as - 3 (FOR 40 CH.) 10. Use a Power meter to test the input optical power of the adding wavelengths of east M40.Adjust the variable attenuator of each wavelength conversion board and make the input optical power of the wavelength on the east M40 reach the standard value (-18dBm). 11. Repeat the same procedure to adjust the power levels of other direction.

Prithvi Information Solution Ltd.

OPTICAL POWER LEVELS IN OADM


FOR 16 LAMBDA SYSTEM
MEASUREMENT POINT POWER LEVEL(dBm)
IN POINT AT OBU -4

FOR 32 LAMBDA SYSTEM


MEASUREMENT POINT POWER LEVEL(dBm)

IN POINT AT OPU
IN POINT AT OBU -7 A01,A02 OF MR2 IN ITERFACE OF EACH OTU

-9
-18 - 6 TO 8 19 14

IN POINT AT OPU

- 12

OUT POINT AT OBU OUT POINT AT OPU

A01,A02 OF MR2

-18

FOR 40 LAMBDA SYSTEM


MEASUREMENT POINT POWER LEVEL(dBm)
-3 -4 -18 - 6 TO 8 20 17 IN POINT AT OBU IN POINT AT OAU

IN ITERFACE OF EACH OTU

- 6 TO 8

OUT POINT AT OBU

16

A01,A02 OF MR2 IN ITERFACE OF EACH OTU

OUT POINT AT OPU

11

OUT POINT AT OBU OUT POINT AT OAU Prithvi Information Solution Ltd.