Está en la página 1de 7

06.

April 2006

Security Level:

Upgrading the OptiX RTN 620 to the Hybrid Radio FAQ

www.huawei.com

Transmission Network Marketing Support Dept, 2009-8-17

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

How to check the ODU hardware version?


Answer: Use Navigator to execute command : cfg-get-bdversion:Bid Example: :cfg-get-bdversion:18 BOARD-VERSION
BID BD-TYPE RVER DVER HVER ONLINE-FLAG BDVER-TIME

18

odu

0x01 0x0a 0x0004 online

2009-05-13 11:00:00

Total records :1 RVER means main version, DVER means sub version, HVER means hardware version So this ODU software version is 1.10,hardware version is 0x0004
HUAWEI TECHNOLOGIES Co., Ltd. HUAWEI Confidential
Page 2

There is LICENSE_LOST alarm when the SCC version is upgraded from R1 to R2/R3
Answer: There is no license control in R1 version. and R2/R3 add
this function. So we need to load the license again when the SCC version is upgraded from R1 to R2/R3. It doesnt not need to load the license again if the current version is already R2/R3

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 3

There is NO_BD_SOFT alarm in IF1A(IF1B) card when the SCC board is upgraded from R1 to R2/R3
Reason: For R1 version, the SCC board only support one FPGA file,R2/R3 support 2 FPGA file. If the second FPGA is not loaded, there will be NO_BD_SOFT alarm Solution: We need to load the load the second FPGA file if1p.pga to IF1A(IF1B) card Remark: The board will be reset when the FGPA file is activated, the service will be down

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 4

How to calculate the TDM license?


Example: One RTN620 NE has 2 direction, one direction is 1+1 protection, work mode is 16E1 16 QAM the other direction is 1+0,work mod is 4E1 QPSK If the link is 1+1 protection (HSB/FD/SD), the license should be doubled so the license should be 216E1 4E1=36E1 at least. Huawei RTN license have 8E1 16E1 32E1 48E1 64E1 128E1 MAX type. So 48E1 license should be loaded in this NE

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 5

Does Hybrid support 1+1 Protection (HSB/FD/SD)?


Answer: Yes Remark:
There is no data cross connection platform in RTN600,so EMS6 board is needed to realize the 1+1 Protection. For detailed configuration, please check the attachment

Hybrid MW 1+1 Preotection

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential

Page 6

06.April 2006

Security Level:

Thank You
www.huawei.com
www.huawei.com

HUAWEI TECHNOLOGIES Co., Ltd.

HUAWEI Confidential