WHAT IS REFRIGERATION?
THE PROCESS IN WHICH WORK IS DONE TO MOVE HEAT FROM A COLD REGION TO A HOT REGION.
work is done on the gas molecules. That means that additional energy is transferred to the gas molecules from the source of compression so as to increase temperature of gas and vice-aversa.
HEAT FLOWS FROM HIGHER TEMPERATURE REGION TO LOWER TEMPERATURE REGION-: When two substances are
placed in direct contact, heat naturally flows from the hotter substance to the cooler one unless both the bodies attain equal temperatures.
4
www.wikibooks.org
When the gas packet is at maximum compression, the gas ejects the heat back into the hot heat exchanger.
8
WORKING(contd)
Gas expands while moving to left and cools.
WORKING(contd)
Temperature gradient across the stack is established.
Hot fluid
Very cold
Very hot
ANIMATED WORKING
11
THE P Vs V PLOT
12
EXPERIMENTAL STUDY ON PERFORMANCE OF THERMOACOUSTIC REFRIGERATION BY EMMANUEL C. NSOFOR AND AZRAI ALI
Hot heat exchanger was maintained at ambient temperature. Cold heat exchanger temperature was varied to achieve a number of temperature differences along the stack. Helium gas was selected as the working fluid. The resonator was constructed from aluminium tubing but with plastic tubing at the inner portion to reduce heat loss by conduction. Parallel plate stack made from a thermoplastic material was used. An audio generator with frequency range from 10Hz to 1MHZ was used to produce sound wave.
13
14
LOCATION OF THERMOCOUPLE
15
EXPERIMENTAL SETUP
16
EXPERIMENTAL SETUP(contd)
17
EXPERIMENTAL SETUP(contd)
18
WORKING PARAMETERS
19
Temperature-time history(at the hot end of the stack) for constant cooling load and mean pressure for various frequencies
20
Temperature-time history(at the hot end of the stack) for constant mean pressure and frequency for various cooling load.
21
Temperature-frequency history(at the hot end of the stack) for constant mean pressure and variable load
22
Temperature difference at the ends of the stack verses mean pressure at constant frequency and cooling load.
23
Cooling load verses temperature difference at the ends of the stack at constant frequency and mean pressure
24
Temperature difference at the ends of the stack verses frequency for constant cooling load and mean pressure
25
EXPERIMENTAL RESULTS
The temperature difference between the hot end and cold end of the stack ranged from 0C to 15C. Cooling load increases with the increase in the temperature difference between the two ends of the stack. For a thermoacoustic refrigerating system, there exist for a given frequency, an optimum pressure that results in a higher cooling temperature difference and thus a higher cooling load. This frequency is the resonance frequency.
26
CONCLUSION
The thermoacoustic refrigeration is environment friendly method of refrigeration technique. The technique was effectively used in the US space shuttle DISCOVERY. So we can expect extensive application of this technology in various areas of refrigeration.
27
REFERENCES
B Ramesh Nayak, Bheemsha, Pundarika. G, Design of parallel plate stack for a thermoacoustic refrigerator, International Journal of Advanced Scientific and Technical Research, 2011. Emmanuel C. Nsofor, Azrai Ali, Experimental study on the performance of the thermoacoustic refrigerating system, Applied thermal engineering, 2009. Jonathan Newman, Bob Cariste, Thermoacoustic Refrigeration, GSET Research Journal, 2006.
28
THANK YOU