Temperature, fixed from/to [C]

Control cables CF130.UL CF140.UL CF5 CF6 CF77.UL.D CF78.UL CF170.D CF180 CF2 CF9 CF10 CF9.UL CF10.UL CF98 CF99 PVC PVC PVC PVC PUR PUR PUR PUR PUR TPE TPE TPE TPE TPE TPE
       

7,5-10 7,5-15 6,8-7,5 6,8-7,5 6,8-7,5 6,8-7,5 7,5-10 7,5-15 5 5 5 5 5 4 4

-5/ +70 -5/ +70 -5/ +70 -5/ +70 -35/ +80 -35/ +80 -35/ +80 -35/ +80 -20/ +80 -35/ +100 -35/ +100 -35/ +100 -35/ +100 -35/ +90 -35/ +90

5 5 4 4 4 4 5 5 4 3 3 3 3 3 3

-20/ +70 -20/ +70 -20/ +70 -20/ +70 -40/ +80 -40/ +80 -40/ +80 -40/ +80 -40/ +80 -40/ +100 -40/ +100 -40/ +100 -40/ +100 -40/ +90 -40/ +90

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.

Get online and use all the advantages of www.igus.eu Download the eplan-library for any type of cables www.igus.eu/eplan-download
4.2

Price index

Shield

Torsion resistant

Flame-retardant

Approvals and standards

Number of cores

Chainflex types
Halogen-free a max. [m/s2] v max. unsupported [m/s] UV-resistant Oil-resistant v max. gliding [m/s]                                                 

Cross section [mm2]

4.50 3 3 10 10 10 10 3 3 10 10 10 10 10 10 10 2 2 5 5 5 5 2 2 5 6 6 6 6 6 6 20 20 80 80 80 80 20 20 80 100 100 100 100 100 100 2 - 30 3 - 36 2 - 42 2 - 36 2 - 36 3 - 25 3 - 30 3 - 18 3 - 48 2 - 36 2 - 25 2 - 36 2 - 25 2-8 2-8 0,25 - 6,0 0,25 - 2,5 0,25 - 2,5 0,25 - 2,5 0,25 - 4,0 0,50 - 4,0 0,50 - 10,0 0,50 - 2,5 0,14 - 1,5 0,25 - 35,0 0,14 - 4,0 0,25 - 6,0 0,25 - 4,0 0,14 - 0,5 0,14 - 0,34 4.52 4.56 4.60 4.64 4.68 4.70 4.72 4.74 4.76 4.80 4.84 4.88 4.92 4.96 4.98

Chainflex types mentioned in the catalogue as resistant to bio oil have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

Table of contents according to industries

Page 4.420

Chain cable guarantee! Ask for fully harnessed and preassembled ReadyChains increase your cash-flow and profit immediately. The igus system guarantee also covers components delivered loose. www.readychain.eu
4.3

Page

Minimum bending radius. moved [factor x d]

Minimum bending radius, fixed [factor x d]

Chainflex types
Temperature, moved from/to [C] Chainflex Cable Jacket

Temperature, fixed from/to [C]

Data cables CF240 CF211 NEW* CF112 NEW* CF113 CF11 CF12 PVC PVC PUR PUR TPE TPE
     

10-12 10 10 10 10 10

-5/ +70 -5/ +70 -35/ +80 -35/ +80 -35/ +100 -35/ +100

5 5 5 5 5 5

-20/ +70 -20/ +70 -40/ +80 -40/ +80 -40/ +100 -40/ +100

Bus cables (with selection chart for Chainflex bus cables) NEW* CFBUS.PVC PVC NEW* CFBUS.PUR PUR CF BUS CF11.LC CF11.LC.D CF14 CAT5 Measuring system cables CF211 CF113.D CF111.D CF11.D Koax cables CF Koax 1 Fibre optic cable (FOC) CFLK CFLG.2H NEW* CFLG.LB CFLG. G
4.4
* New in this catalog.

     

12,5 12,5 10-12,5 10 10 12,5

-5/ +70 -35/ +70 -35/ +70 -35/ +70 -35/ +70 -35/ +70

7,5 7,5 5 5 5 7,5

-20/ +70 -40/ +70 -40/ +70 -40/ +70 -40/ +70 -40/ +70

TPE TPE TPE TPE

PVC PUR TPE TPE

   

10 10 12 10

-5/ +70 -20/ +80 -35/ +100 -35/ +100

5 5 6 5

-20/ +70 -40/ +80 -40/ +100 -40/ +100

TPE

10

-35/ +100

7,5

-40/ +100

PUR PUR TPE TPE

12,5 12,5 5 15

-20/ +70 -20/ +60 -40/ +60 -40/ +60

7,5 7,5 5 8,5

-25/ +70 -25/ +60 -40/ +60 -40/ +60

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible.

Price index

Shield

Torsion resistant

Flame-retardant

Approvals and standards

Number of cores

Chainflex types
Halogen-free a max. [m/s2] v max. unsupported [m/s] UV-resistant Oil-resistant v max. gliding [m/s]                  

Cross section [mm2]

4.100 3 5 10 10 10 10 2 3 5 5 6 6 20 50 80 80 100 100 3 - 24 2 - 28 4 - 12 4 - 12 4 - 36 4 - 28 0,14 - 0,34 4.102 0,25 - 0,5 0,25 - 0,5 0,25 - 0,5 0,14 - 2,5 0,25 - 1,0 4.104 4.106 4.108 4.110 4.112 4.114
                  

2 2 10 10 10 10 6 6 6 6

30 30 100 100 100 100

2-8 2-8 2 - 13 2-9 2-6 4 - 10

0,15 - 0,5 0,15 - 0,5 0,08 - 1,5 0,25 - 1,0 0,25 - 1,5 0,25

4.118 4.120 4.122 4.126 4.128 4.130

  

        

5 5 2 10

3 3

50 50 30

6 - 16 4 - 17 7 - 16 4 - 17

0,14 -1,0 0,14 -1,0 0,14 - 0,5 0,14 - 1,0

4.132 4.136 4.142 4.146

100

10

100

1-5

4.152 4.154

   

  

10 10 10 10

5 6 6 6

20 20 20 20

1 2 2 6 - 12

980/1000 m 50 + 62,5/125, 200/230 m 50 + 62,5/125 50 + 62,5/125 m

4.158 4.160 4.162 4.164


4.5

Chainflex types mentioned in the catalogue as resistant to bio oil have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

Page

Minimum bending radius, moved [factor x d]

Minimum bending radius, fixed [factor x d]

Chainflex types
Temperature, moved from/to [C] Chainflex Cable Jacket

Temperature, fixed from/to [C]

Servo cables NEW* CF210.UL CF21.UL PVC PVC


   

10 7,5 10 7,5

-5/ +70 -5/ +70 -20/ +80 -20/ +80

5 4 5 4

-20/ +70 -20/ +70 -40/ +80 -40/ +80

NEW* CF270.UL.D PUR CF27.D Power cables CF30 CF31 CF34.UL.D CF35.UL CF37.D CF38 PVC PVC TPE TPE TPE TPE PUR

7,5


-5/ +70 -5/ +70 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +70 -35/ +70 -20/ +80

4 4 4 4 4 4 4 4 4 4 4 4 4 4 7,5

-20/ +70 -20/ +70 -40/ +90 -40/ +90 -40/ +90 -40/ +90 -40/ +90 -40/ +90 -40/ +90 -40/ +90 -40/ +90 -40/ +90 -40/ +70 -40/ +70 -30/ +80

7,5 7,5

7,5 7,5

7,5 7,5 7,5

CF300.UL.D TPE CFPE CF310.UL CF330.D CF340 NEW* CF FLAT CF BRAID TPE TPE TPE TPE TPE TPE
   

7,5 7,5 7,5 5 7,5 7,5 10

CF BRAID.C TPE CF CRANE igupren

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible. Chainflex types mentioned in the catalogue as resistant to bio oil have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

4.6

* New in this catalog.

Price index

Shield

Torsion resistant

Flame-retardant

Approvals and standards

Number of cores

Chainflex types
Halogen-free a max. [m/s2] v max. unsupported [m/s] UV-resistant Oil-resistant v max. gliding [m/s]              

Cross section [mm2]

4.166 10 10 10 10 5 5 50 80 50 80 4-8 6-8 4-8 4-8


1,5 - 6 / Pairs 0,75 - 1,5

4.168 4.170 4.174 4.178 4.182

0,75 - 35 / Pairs 0,34 - 1,5

1 - 35 / Pairs 0,5 - 1,5

0,75 - 50 / Pairs 0,34 - 1,5

   

       

                 

10 10

5 5 6 6 6 6 6 6 6 6 6 6 6 6 6

80 80 80 80 80 80 100 100 100 100 100 100 80 80 50

4-5 4-5 3-5 3-4 3-5 3-4 1 1 1 1 1 1 8 8 1

1,5 - 50 1,5 - 70 1,5 - 50 0,5 - 50 1,5 - 50 0,5 - 50 6 - 185 1,5 - 35 4 - 185 6 - 185 4 - 185 2,5 - 4 2,5 2,5 25 - 95

4.184 4.186 4.188 4.190 4.192 4.194 4.196 4.198 4.200 4.202 4.204 4.206 4.208 4.208 4.210

10 10

10 10

  

     

 

10 10 10

10 10 10 10 10 10

  

  

Table of contents according to industries

Page 4.420

Page 4.7

Minimum bending radius, moved [factor x d]

Minimum bending radius, fixed [factor x d]

Chainflex types
Temperature, moved from/to [C] Chainflex Cable Jacket

Temperature, fixed from/to [C]

Pneumatic hose CF AIR PU 10 10 -25/ +80 -25/ +60 8 8 -40/ +85 -30/ +65

CF Clean AIR PE Twistable cables NEW* CF ROBOT9 PUR NEW* CF ROBOT8 PUR NEW* CF ROBOT4 PUR NEW* CF ROBOT5 TPE NEW* CF ROBOT6 PUR NEW* CF ROBOT7 PUR CF ROBOT TPE
    

10 10 10 12,5 10 10 10

-25/ +80 -20/ +70 -25/ +80 -20/ +60 -25/ +80 -25/ +80 -35/ +100

4 7,5 4 7,5 4 4 4

-40/ +80 -25/ +70 -40/ +80 -25/ +60 -40/ +80 -40/ +80 -40/ +100

These values are based on concrete applications or tests. These values do not represent the limit of what is technically feasible. Chainflex types mentioned in the catalogue as resistant to bio oil have been tested by DEA following VDMA 24568 with Plantocut 8 S-MB.

4.8

* New in this catalog.

Price index

Shield

Torsion resistant

Flame-retardant

Approvals and standards

Number of cores

Chainflex types
Halogen-free a max. [m/s2] v max. unsupported [m/s] UV-resistant Oil-resistant v max. gliding [m/s]    

Cross section [mm2]

10 10

6 6

50 50

4.212 4.214 4.216

  

   

      

      

10 10 10 10 10 10 10

10 10 10 10 10 10 10

4 - 34 2-8 6 - 12 2 3 3 - 12 1

0,25 - 1

4.220

0,14 - 0,35 4.222 0,14 - 0,5


50 + 62,5/125 m

4.224 4.226 4.228 4.228 4.230

  

  

10 - 35 0,25 - 4 10 - 50

Table of contents according to industries

Page 4.420

Page 4.9

Chainflex ReadyCable
Cable type

Jacket

Page

Video-, vision engineering/bus technology (with camera reference list4page 4.254) FireWire USB GigE FOC FOC Koax
Ready-made cable Ready-made cable Ready-made cable Ready-made cable Ready-made cable (Robotics) Ready-made cable TPE TPE TPE PUR TPE TPE

4.232
4.234 4.238 4.242 4.244 4.248 4.250

Network-/ethernet-/fibre cables (FOC)/fieldbus CFLG.6G CFLG.12G CAT5 CAT5 CAT6 Profibus NEW* NEW*
Gradient fibre glass cable, ready-made Gradient fibre glass cable, ready-made Ethernet cable, ready-made Ethernet cable, ready-made, L-/T-angle Ethernet cable, ready-made Field bus cable, ready-made TPE TPE TPE TPE TPE PVC/PUR/TPE

4.258
4.260 4.262 4.264 4.266 4.268 4.270

Initiators CF9 CF.INI (minimum bending radius 5 x d)


Direct line/Connecting cable TPE

4.276
4.278

Initiators CF10 CF.INI (minimum bending radius 5 x d) 360 shielded


Direct line/Connecting cable TPE 4.284

Initiators CF98 CF.INI (minimum bending radius 4 x d)


Direct line/Connecting cable TPE 4.286

4.10

* New in this catalog.

Chainflex ReadyCable
Selection table according to systems (Part No. and sheath materials)

Jacket

Page

Cables for Drive Technology B&R Baumller Beckhoff Berger Lahr NEW* NEW* NEW* NEW*
PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE TPE PUR/TPE

4.291
4.294 4.294 4.296 4.296 4.297 4.298 4.300 4.301 4.301 4.301 4.302 4.303 4.303 4.305 4.306 4.307

Control Techniques NEW* Danaher Motion ELAU Fagor Fanuc Heidenhain Lenze NUM Rexroth SEW Siemens Stber NEW* NEW* NEW* NEW* NEW* NEW*

PUR/TPE PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE PVC/PUR/TPE

"Baumller" is a registered trademark of "Baumller Nrnberg GmbH, Nrnberg" / "Beckhoff" is a registered trademark of "Mr. Hans Beckhoff, Verl" / "Berger Lahr" is a registered trademark of "Schneider Electric Motion Deutschland GmbH & Co.KG, Lahr" / "Danaher Motion" is a registered trademark of "Danaher Motion Technology LLC, Delaware" / "ELAU" is a registered trademark of "Elektronik-Automations-AG, Marktheidenfeld" / "Fanuc" is a registered trademark of "Fanuc Ltd., Tokyo/Yamanashi" / "Heidenhain" is a registered trademark of "Dr. Johannes Heidenhain GmbH, Traunreut" / "Lenze" is a registered trademark of "Lenze GmbH & Co. KG, Extertal" / "Rexroth" is a registered trademark of "Bosch Rexroth GmbH, Lohr" / "SEW" is a registered trademark of "SEW-EURODRIVE GmbH & Co KG, Bruchsal" / "Siemens" is a registered trademark of "Siemens AG, Mnchen" / "Stber" is a registered trademark of "Stber Antriebstechnik GmbH & Co. KG, Pforzheim"

* New in this catalog.

4.11

Chainflex accessory
Connectors Please find more informations under: www.igus.eu/connectors Test order test igus! SERIE A SERIE B SERIE B SERIE M17 SERIE C SERIE D SERIE S
Signal connector Power connector Power connector Signal- and power connector Power connector Power connector Power connector

Tools, accessories SUB-D Glands Strain Relief Please find more informations under: www.igus.eu/strainrelief Chainfix steel clamps Adjustable with hexagon socket Chainfix Clips Snap-on strain relief device Chainfix Nugget Strain relief for cables Strain relief separator Separator with integrated teeth Tiewrap plates Bolted or clip-on Chainfix-tiewrap plates For C-profile, clip-on igus blocks Strain relief for hoses ReadyChain Please find more informations under: www.igus.eu/readychain igus ReadyChain Ready-made Energy Chain Systems

SUB-D Signal connector

5.526

4.12

Chainflex
Data and Schedules
Calculation of the copper surcharge Load-Carrying Capacity of Cables Electrotechnical data Chemical resistance

Page

Technical Data and Schedules/user information/contact


Chainflex cable's classification according to the criteria requirements, oil-resistance and travel distance

4.404
4.14-4.15

DIN 47100 colour code/Copper wire dimensions according to Anglo-American AWG numbers

4.406 4.406 4.407 4.408 4.414

Informations
The General Conditions User information, Disclaimer, KTG, Product illustrations Technical notes Approbation and Approvals Configure and order cables online, igus & eplan Chainflex according to Industries

4.416 4.416 4.416 4.417 4.418 4.420

Contact igus
Fax Customer-specific cables for Energy Chain Systems Definition of the icons used in the catalogue 4.419 4.424

4.13

Your way through the Chainflex catalogue

CF210.UL CF270.UL.D CF111.D CF130.UL CF140.UL CF170.D CF180 CFBUS.PVC CFBUS.PUR CF240 CF77.UL.D CF78.UL CF5 CF6 CF211 CF21.UL CF30 CF31 CFLK CF2 CF112 CF113/CF113.D CFLG.2H CF27.D CF14.CAT5 CFCRANE CF9.UL CF10.UL CF11/CF11.D CF12 CF11.LC./LC.D CFBUS CFKOAX CF34.UL.D CF35.UL CF300.UL.D CFPE CF310.UL CFLG.LB CF9 CF10 CF98 CF99 CFLG.G CF37.D CF38 CF330.D CF340 CFFLAT

4 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 5 5 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 7 7 7 7 7 7 7 7 7 7 7

1 1 1 2 2 1 1 1 1 2 3 3 3 3 3 3 3 3 1 3 3 3 3 3 3 4 4 4 4 4 4 4 4 4 4 4 4 4 3 4 4 4 4 4 4 4 4 4 4

4.14

Resistance to oil

Chainflex cable's classific

Travel distance

Requirements

Chainflex cable

2 3 4 1 1 3 3 2 3 2 3 3 2 2 2 2 2 2 3 3 3 3 3 3 4 3 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4

cation according to the criteria requirements, oil-resistance and travel distance.


To make the choice easier for you, we have classified all Chainflex-cables after the criteria "requirements, oilresistance and travel distance". The higher the number the better the cable. Example: You are looking for a cable which resists highest mechanical requirements. Aside it should be oilresistant following VDMA 24568. The travel distance should be up to 400 m and more for gliding applications. You choose from the classification overview: Requirements: Travel distance: Resistance to oil: 7 4 4

This results in the cable's class here "Class 7.4.4" that you can take out of each product's page.

The Chainflex class is composed of 3 parts:


Requirements 1 up to 7 Travel distance 1 up to 4 Resistance to oil 1 up to 4

Resistance to oil

1: No resistance to oil 2: Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1) 3: Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2) 4: Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB)

Travel distance

1: freely suspended 2: freely suspended and gliding up to 50 m 3: freely suspended and gliding up to 100 m 4: freely suspended and gliding up to 400 m and more

Requirements

1: Flexible cables 2: Highly flexible cables 3: Chain-suitable cables without special structure (e.g. stranding in layers) for the use in E-Chains. 4: Cables with special structure for the permanent move in E-Chains for medium requirements and radii from 7,5 x d, speed up to 3 m/s 5: Cables for the permanent move in E-Chains for high load requirements and radii from 6,8 x d, speed up to 10 m/s 6: Cables for the permanent move in E-Chains for highest load requirements and radii from 5 x d, speed up to 10 m/s 7: Cables for the permanent move in E-Chains for highest load requirements and smallest radii, indoor and outdoor, radii from 4 x d, speed up to 10 m/s and more In theory the following classes would be possible: lowest "Class 1.1.1", highest "Class 7.4.4"
4.15

Fleece

Chainflex ...
The tricks and ingenious features of...
From the customer's point of view, a flexible energy supply system only needs to function properly. However, this demand presupposes the perfect operation of all components, including the cables being used in this system. And this is exactly where problems came up in the early 1980s. Due to constantly and frequently even tremendously increasing loads resulting from the application of automation technology, guided cables often failed although the energy supply system itself was functioning perfectly. In extreme cases, failures caused by "corkscrews" and core ruptures brought the entire production process to a standstill and resulted in high costs. In order to find a solution to this unsatisfactory situation for its customers, igus decided to take the initiative. As the first company worldwide, igus began to develop complete Energy Chain Systems. Chainflex cables and Energy Chains are now being offered as a delivery from a single source and with a system guarantee depending on the application in each case. Based on the increasing know-how gained since 1989 and on the very sophisticated series of tests that have been conducted since then, design principles were and are still being created that help prevent machine downtimes in factories throughout the world today.

Cores stranded in Layers Extruded, non-tensionproof centre element Picture 1: Chainsuitable cable stranded in layers Single-wire bundles with short pitch lengths

How can "corkscrews" be prevented?


Center element for high tensile stresses Here, the term "corkscrew" does not refer to a useful instrument for wine connoisseurs. Instead, it refers to the permanent deformation of guided, moved cables caused by excessive stressing which, in most cases, results in core rupture almost immediately afterwards. How does this happen? How can "corkscrews" be prevented? An important factor here in addition to a sensible design of the total Energy Chain System is the construction of the guided cables. Basically speaking, a clear distinction can be made between cables stranded in bundles and cables stranded in layers (see picture 4).

Highly abrasionPicture 2: resistant, gussetLitz wire and filled extruded core structures jacket Total shield with of a Chainflex cable optimized braiding angle Picture 3: igus stranding in bundles around center cord Gusset-filled extruded inner jacket

Properties of stranding in layers


Stranding in layers is significantly easier to produce and is therefore offered on the market in so-called "chain-suitable" cables at low cost. But what appears to be tempting at first glance can quickly turn into an expensive mistake when a "corkscrew" immobilizes the system being operated with these cables. How do these problems arise? A look at the cable structure can be quite helpful (see picture 1). In the case of stranding in layers, the cable cores are mostly stranded more or less firmly and relatively long in several layers around a center and are then provided with a jacket extruded to the form of a tube. In the case of shielded cables, the cores are wrapped up with fleece or foils. But what, for example, happens to a similarly structured 12-core cable during normal operation? The bending process compresses, in the movement of the core, the inner radius of the cable and stretches the core in the outer radius. Initially, this works quite well because the elasticity of the material is still sufficient. But very soon, material fatigue causes permanent deformations, and then, due to excursion from the specified paths, the cores make their "own compressing and stretching zones": The corkscrew is created, then followed rather quickly by core ruptures most of the time.

Center element for high tensile stresses 4.16

lasts or your money back!


...the Chainflex design and why we feel so confident about this design
Stranding in bundles tried and tested expensively and efficiently millions of times since 1989
Stranding in bundles eliminates these problems by means of its very sophisticated, multiply stranded internal structure. Here, the litz wires are stranded with a special pitch length first and then the resulting cores are stranded into single core bundles. For large cross sections, this is done around a strain relief element. The next step is the renewed stranding of this core bundle around a tension-proof center a genuine center cord. (see picture 2) Due to this multiple stranding of the cores, all cores change the inner radius and the outer radius of the bent cable several times at identical spacing distances. Pulling and compressing forces balance one another around the high-tensile center cord that gives the stranded structure its necessary inner stability. Accordingly, the stranding remains stable even under maximum bending stress (see picture 3).

Dictionary of defects
Core rupture
Failure of electric conductivity due to broken copper wires as a result of subjecting the individual cores to mechanical overload/ tensile load under constant bending stress. In most cases, the causes are incorrect litz wires and/or incorrect stranding pitch directions and lengths.

Insulation damage
Short circuits due to damage to the insulation above the conductor. The cause can be material fatigue under constant bending stress or material abrasion within the stranded structure. Single-wire breakage of the conductor or the shield braid result in perforation of the insulation.

Corkscrew What are EMC problems and shield wire breakage?


In principle, cable shields must fulfil two tasks: G Protecting the cables from external interferences G Shielding any interferences before transmitting them to the outside Both tasks are equally important because faulty signals can cause considerable consequential damage in the system itself as well as in any external systems. Furthermore, this is an especially problematic point due to the fact that incorrect shielding usually cannot be detected from outside, and this is something that makes the trouble-shooting procedure extremely difficult. How can these kinds of problems arise in the first place? Once again, the answer is to be found in the internal structure of the cable itself: Is the shielding designed for the movements of the cable? Although it may be very easy to shield a fixed cable, it is much more difficult to guarantee the permanent shielding of a moving cable. In the case of so-called "chain-suitable" cables, for example, the stranding bond of an intermediate layer is wrapped up with foils or fleeces. This stranding bond is supposed to guarantee the separation between the cores and the shield braid. But something that functions quite well for the fixed installation of cables is often quite insufficient in the case of moving cables. This has to do with the fact that the foils and fleeces do not create a bond between the stranding, shield and jacket and may fall apart under stress. Consequently, the metallic shield then rubs on the insulation of the cores short circuits are then to be expected. An externally detectable screw-like deformation of the entire cable due to broken copper wires as the result of subjecting the individual cores to mechanical overload/ tensile load during the bending process. In most cases, the causes are unfavorable superstructure properties (stranding in layers, missing center, loose jackets extruded to the form of a "tube") and subjecting the cables to high bending stress.

Jacket abrasion
The jacket is rubbed off down to the stranding or down to the total shield. In most cases, the causes are incorrect selection of materials and/or unfavorable extrusion processes resulting in detrimental surface properties so that abrasion is an unavoidable effect.

Jacket swelling/ jacket breakage


Jacket becomes soft and deformed or breaks until the stranding/shield can be seen. The cause can be the incorrect selection of materials with respect to the oils or other chemical substances being used.

Shielding losses/ EMC problems


Electromagnetic interferences inside or outside an electric cable. In most cases, the cause is shield wire breakage due to mechanical overload with incorrect shield braid angles. Other causes include loose braids over foils without supporting effects or very open coverings.

Chainflex ...
The tricks and ingenious features of...
But the production of the shield itself is very time-consuming and cost-intensive and may have been the reason for the use of open braid shields or even simple wire wrappings. The disadvantages are quite obvious: Open shields only possess a limited shielding effect in their moved state motion and expansion reduce this effect even further. The type of shield is therefore an important point that is not even mentioned in some catalogues. In its up to approx. 70% linearly and approx. 90% optically covered cables, igus eliminates these weak points by means of an optimized internal structure. In virtually all shielded Chainflex cables, a gusset-filled extruded inner jacket over the stranded structure is therefore used. This "second jacket" fulfils two tasks: G It holds the stranded structure together and guides the individual cores as in a channel. G It serves as a firm, round base for a very tight-fitting shield.

Shield wire breakage and how this can be prevented


And even during the production of the shield, there are many things that can be done correctly or incorrectly. Here, an important parameter is the braiding angle. In the case of "chain-suitable" cables, a tensile load of the shield wires in the outer radius of the cable must usually be taken into account. If an unfavorable braiding angle is to be added, the tensile load increases even further and shield wire breakage is the result. The consequences range from reduced shielding effects right up to short circuits whenever the sharp wire ends penetrate through the fleeces or foils into the cores. Here, a useful tip: If, after the insulation has been stripped off, the shield can be easily pushed back over the jacket, the shield is then usually unsuitable for use in moved flexible energy supply systems! This is a problem that igus has now solved with its direct approach: G The shield braiding angle determined in long-term tests efficiently neutralizes the tensile forces and is therefore highly suitable for Energy Chains. G Due to the stable inner jacket, the shield cannot wander uncontrolled. G The shield itself has a torsion protection effect on the stranded structure.

Jacket breakage at (36x0.142) after only 900.000 to-and-fro cycles with a bending factor of 7.8 x d

Jacket abrasion/ jacket breakage


Whereas defects in the internal structure are hardly detectable on the outside, jacket problems strike the eye immediately. The jacket is the first protection for the complicated internal structure. This is why broken, worn and swollen jackets are a serious quality defect. To prevent this problem, the igus customer can select among 7 acket materials to adapt his Energy Chain cables to suit the conditions of the respective environment.

4.18

lasts or your money back!


...the Chainflex design and why we feel so confident about this design
Gusset-filled extruded jacket
Here, not only the material is an important factor but also the production process. In the case of the so-called "chain-suitable" cables, the jackets are usually produced extruded to the form of a tube and therefore do not provide the stranded structure with the necessary support for constant bending processes. The stranded structure can fall apart. Therefore, igus is the first manufacturer of Energy Chain Systems to offer the so-called the "gusset-filled extruded" jacket. Here, the jacket material is injected between the core stranding powdered with talc and ensures that the stranded structure does not open up and also makes sure that the cores are guided as in a channel. The special characteristic of this type of production is that the intermediate spaces, which are created between the cores during the stranding process, are completely filled with jacket material by the high extrusion pressure. As a result, the jacket material creates a channel-like guide which allows the cores to carry out a defined longitudinal movement. The jacket also provides a supporting function for the stranding.

The quality bundles of igus Chainflex cables


G G G G G G Strain-relieving center Stranding in bundles Gusset-filled extruded inner jacket in shielded cables Enclosed shield braid Optimized shield braiding angle Gusset-filled extruded jacket

7 basic rules for a good cable


1. Strain-relieving center
Clear space is created in the center of a cable according to the number of cores and the cross section of each cable. This center should be filled, as far as possible, with a genuine center cord (and not, as frequently the case, with fillers or dummy cores consisting of waste materials). These measures will then efficiently protect the stranded structure situated above and prevent the stranding from wandering into the middle of the cable. However, due to the insulating materials being used, this stranded structure should still be defined in mobile form within the stranding. Starting from a quantity of 12 cores, however, the method of stranding in bundles should be applied.

5. Inner jacket
A gusset-filled extruded inner jacket must be used instead of inexpensive fleeces, fillers or accessory fillers. This measure ensures that the stranded structure is efficiently guided in longitudinal direction. Moreover, the stranded structure cannot fall apart or wander off.

2. Litz wire structure


With respect to the selection of litz wires, the maximum flexibility has proved to be the best solution. Although very flexible conductors can be made using very thin individual wires, these conductors tend toward extreme formation of kinks. Long-term series of tests provided the result of a shielded combination of single-wire diameter, pitch length and pitch direction as the best bending-resistant solution.

6. Shielding
The total shield should be made tight using an optimized shield braiding angle over an extruded inner jacket. Loose open braids or wrapped stranding reduce the EMC protection considerably and can fail very quickly due to shield wire breakage. A tight total braid shield also has a torsion protection effect on the stranded structure.

3. Core insulation
The insulation materials must be made so that they do not stick to one another within the cable. Furthermore, the insulation is also required to support the stranded individual wires of the conductor. Accordingly, only the highestquality, high-pressure-extruded PVC or TPE materials that have proved their tested reliability in millions of core kilometers are then used in Energy Chain applications.

7. Outer jacket
The material-optimized outer jacket can fulfil many different requirements: From UV-resistant to low-temperature-flexible, and from oil-resistant to cost-optimized. But these outer jackets must have one thing in common: A jacket material must be highly abrasion-resistant but not be allowed to stick to anything. It must be flexible but also provide a supporting function. In any case, the jacket should also be extruded under pressure (gusset-filled). 4.19

4. Stranding
The stranded structure must be stranded around a stable, tension-proof center with an optimized short pitch length.

Sectional views through


Detailed structure of igus control, data, servo and motor
Chainflex control cable, unshielded
Individual bundles with optimized pitch length and pitch direction

Center element for high tensile stresses

Single-wire diameter optimized for Energy Chains

Highly abrasion-resistant, gusset-filled extruded jacket

Chainflex control cable, shielded


Total shield with optimized braiding angle (covering approx. 70% linear, approx. 90% optical) Gusset-filled extruded inner jacket supports stranding Center element for high tensile stresses Tension-proof center element in individual bundles Pressure extruded jacket

Chainflex data/ sensor cable, shielded


Stranded elements with optimized pitch length and pitch direction Gusset-filled extruded inner jacket supports stranding Center element for high tensile stresses Pair braid shield Total shield with optimized braiding angle (covering approx. 70% linear, approx. 90% optical)
4.20

Pressure extruded jacket

the igus cable types


cables
Chainflex FOC gradient fiber cable
Supporting braid made of glass-yarn-stranded GRP rods Gel-filled fiber sheath FOC fibers

Highly abrasion-resistant TPE jacket

Integrated torsion protection

Chainflex servo cable, shielded


Total shield with optimized braiding angle (covering approx. 70% linear, approx. 90% optical) Optimized single-wire diameter Center element for high tensile stresses Gusset-filled extruded inner jacket Stranding with optimized pitch length and pitch direction Pair braid shield over optimized stranded core pair Highly abrasion-resistant pressure extruded jacket

Chainflex power cable, shielded


Total shield with optimized braiding angle (covering approx. 70% linear, approx. 90% optical) Gusset-filled extruded inner jacket Center element for high tensile stresses Optimized single-wire diameter Stranding with optimized pitch length and pitch direction Highly abrasion-resistant pressure extruded jacket

4.21

Chainflex are the special cables for Energy Chain Systems tested, tested, tested and tested.

Partial view of igus experimental laboratory testing, testing, testing of Chainflex cables

4.22

Purpose of every Chainflex cable


More sensitive applications with high clock cycle numbers, velocities and accelerations as well as sophisticated environmental conditions call for, especially in the field of energy management, tried-and-tested systems that are functionally efficient for a long period of time. EMC safety and the fulfillment of standards and directives such as UL, CSA, VDE, Interbus and Profibus are a necessary requirement today. After all, your automation system is supposed to function correctly non-stop and worldwide even on a low-cost basis. Thats the igus mission.
number of double strokes

No contradiction: Good cables cost less.


Quick availability throughout the world is a significant purchase criterion. Advantages of our cables: successful tests, presence in more than 40 countries around the world and deliverability ex warehouse. This saves time, money, storage capacity and applies to each one of our 950 cable types which you can order without any minimum quantity purchases or surcharges. Which further advantages can be included is something that depends on your specific conditions of use.

Testing of a Chainflex CF5: 7 x 1 in "short" and "long" distances of travel compared with other cables. CF5 with 4,3 x d bending radius
"Short Travel" "Long Travel"

* Cables OK, test abandoned.

number of double strokes

Testing of a Chainflex CF5: 25 x 1 in "short" and "long" distances of travel compared with other cables. CF5 with 4,3 x d bending radius
"Short Travel" "Long Travel"

igus tested

As a manufacturer of Energy Chains and special Energy Chain cables, igus uses the possibility of testing many different types of chains and cables on a practice-oriented basis. At the company-own technical training center in Cologne, numerous series of tests are carried out on a parallel basis under the most difficult conditions. At the present time, there are more than 35 test setups with their test results being summarized in databases. This extensive, current data pool provides precise, reliable information on the actual service life and is also the basis of new product developments at the company. The test data for Energy Chains and cables, but also for readymade systems, are, however, described in such detailed form that igus confirms a functional guarantee for its Energy Chain Systems.

* Cables OK, test abandoned.

4.23

Example 1: tested, tested, tested! Servo cable structure


Conductor core insulation sheath made of TPE fleece polyester foil
G GG GG GG GGG G GG GG GGG G GG GG G GGG G GGGG GGG G GGGG GG GGG GGGG GGGG GGGG GGGG GG GGG GGGG GGGG GGGG GGGG GG

aluminum-coated polyester foil shield center filler Inner jacket made of TPE-E external jacket made of TPE-E

Sample B with fleece and filler experimental production 4x10+(2x1,0) C

The purpose of the test is to determine the advantages of the more expensive internal jacket in shielded servo cables versus the less expensive fleece taping with fillers. In the case of flexible shielded cables, the shield is usually separated from the composite core structure. On the one hand, this is done in order to achieve a rounder braid form and, on the other hand, the friction of the core insulation sheath against the braided shield structure is prevented due to the separation of the cores and shield. This can be achieved with an internal jacket or a fleece taping which is wrapped around the composite core structure. The internal jacket is more sophisticated and is therefore more expensive to produce. Following the twisting process, the composite core structure must run through the extruder in which the internal jacket is then put on. In contrast to this method, the fleece tape can be put on between the twisting point and the reeling-up device during the twisting process and therefore does not require an own work operation.

Sample A with internal jacket igus Chainflex CF27.100.10.02.01.D

4.24

Product information CF27.D page 4.178

Comparison between the igus solution with the gusset-filled internal jacket and the fleece version with fillers
Here, the servo cables are highly flexible motor connection cables with a complete copper shield and an integrated, shielded pair of control cores. This cable type was selected due to the fact that here the problematic case of an outof-round braid form due to the different core cross sections is a significant factor and that the various bending behaviors of the production methods are therefore emphasized. n Sample A: CF27.100.10.02.01.D (igus GmbH) (4x10 mm2) + (2x1,0 mm2) n Sample B: experimental (4x10 mm2) + (2x1,0 mm2) Both cables are provided with identical nominal cross sections and insulation materials. Cable A is equipped with an internal jacket and cable B with a fleece taping and fillers. The experimental production (sample B) already shows the formation of a corkscrew after 145.000 double strokes. In the case of a cable, the so-called corkscrew refers to a wave-shaped deformation like the one that can be seen in the following picture on sample B. Whereas, in the case of cable A, the internal jacket fills up the gussets and a round braid structure is created as a result, cable B requires fillers in the gussets. Like the core, the fillers also consist of filbrated polyethylene. They are easy to compress and are therefore hardly capable of taking over any supporting effects. Whereas the internal jacket, which is made of TPE, and the cable A center, which consists of cordage, hold the cores in a defined position, the cores of cable B are able to move about uncontrolled. During the bending process, a core has detached itself from the composite braid structure and has been shifted in the inner bending radius with respect to the center and on the outer bending radius with respect to the jacket. This results in corkscrew-type deformations that repeat themselves periodically with the pitch length.

5.000.000

5.000.000

Assessment
Despite the extremely low bending factor of 4,76, no signs of wear can be detected in sample A (CF27.100.10.02.01.D) even after 5 million double strokes. Sample B, on the other hand, with its fillers and fleece taping succumbs to a corkscrew formation already after 145.000 double strokes. Accordingly, the result therefore justifies the extra expenditure of the cable with the gusset-filled internal jacket.

Number of double strokes

4.000.000 3.000.000 2.000.000 1.000.000 750.000 500.000 250.000 100.000 50.000 0 145.000

Sample B

Sample A

Sample A: CF27.100.10.02.01.D

Sample B: experimental production 4.25

Example 2: tested, tested, tested! Technical Data Properties CAT5


Alteration of the electrical transmission properties of a CAT5 cable when subjected to an application of stress with the minimum bending radius
High transmission rates of up to 100 Mbit/s place high demands on the cable structure and its materials. The use of the cables in Energy Chains subjects these materials to additional stress and results in long-lasting alterations of the electrical properties. A CF 14.02.04.02.CAT5 cable was selected as a cable to be inspected for high transmission rates. Even when subjected to an application of stress with the minimum bending radius, the cable must also be able to meet the electrical requirements of the IEC 61156-6 standard. In the case of the CF14.02.04.02.CAT5 cable, four pairs of cores are stranded with one another, with each core pair possessing a nominal cross section of 0,25 mm2. The conductor consists of bare copper wires and is surrounded by an insulation sheath consisting of foamed PE.

The following items were inspected: n Characteristic wave impedance of single pairs n Single-pair attenuation n Return loss of single pairs n Near-end crosstalk attenuation of single pairs versus one another The test is to be carried out in order to determine whether the limit values of the IEC standard are complied with by the cable after being subjected to bending stress.

4.26

MHz

0 0 -5 -10 -15 -20 -25 -30 -35


dB/100 m

10

20

30

40

50

60

70

80

90

100

max. norm value new condition according to 332.269 double strokes according to 686.767 double strokes according to 1.561.281 double strokes

Attenuation
The maximum values of the individual attenuation for each pair of cores are specified for the corresponding nominal characteristic wave impedance in dB/100m in the DIN IEC 61156-6 standard. Accordingly, the cables are subdivided into several categories according to the transmission frequency planned to be used. For the cable being inspected, transmission frequencies of up to 100 MHz are planned to be used, which corresponds to the category 5e.

Test result
The attenuation, as a measure of the reduction of the transmitted electrical energy of a signal on the cable, remains, even after more than 1,5 million double strokes, below the specified limit value while being subjected to the application of stress of the minimum bending radius. The characteristic electrical transmission quantities such as characteristic wave impedance, return loss and near-end crosstalk are fulfilled so that, despite applications of high mechanical stress, the electrical values of the IEC standard are complied with for a cable of the category 5.

Product information CF14 CAT5 page 4.130


4.27

Example 3: tested, tested, tested! Millions of double strokes in an energy chain


Profibus cables in permanentlymoving industrial use
For users, it is hard to get an overview of the cable market. Competition between cable suppliers is intensifying and manufacturers are outshining one another in their promises to guarantee service life for cables used in energy chains. Catalogues claim ten million - or even as many as 50 million - double strokes when it comes to the service life of cables used in applications involving movement. On taking a closer look at figures claimed, one must ask how testing was done, or how realistic tests carried out actually were (for example length of travel, test radii, etc.) in order to be able to provide such a guarantee. Even information stating that cables are tested in accordance with VDE (Association of German electrical engineers) 0472, Part 603, test method H, is not helpful when it comes to determining the service life of a cable in energy chains, since the roller testing stand cannot provide any conclusive results and there is no VDE test for special cables in energy chains.

Differences in service life


At the beginning of 2002, a test to determine the service life of profibus cables in a real application was commissioned in igus test laboratory. The aim was to examine any differences in the service life of igus CFBUS.001 Chainflex cable and another market leading profibus cable. The parameters required for the test were selected on the basis of data contained in the competitors catalogue:
Catalogue details Test item A Twin-core profibus cable (2 x AWG24)C Test item B igus Chainflex CFBUS.001 (2 x 0,25 mm2)C

Cross section Guaranteed lifetime Bending radius Diameter Catalogue details

Min. 4,0 Mio. Cycles To be determined in a test > = 60 mm 8,0 mm Issue 2002 85 mm 8,5 mm Issue 2002

Test parameters according to catalogue data of the competition A gliding application was chosen as a suitable test structure since profibus cable systems are usually used here because of their data integrity, particularly over long lengths of travel and long transmission distances. In order to be able to carry out non-destructive testing and hence achieve a large number of bending cycles in a short period of time, a genuine profibus transmission path was erected. In a PC at the fixed end of the test chain there was a profibus master insert card. A connection to a profibus slave was located on the moving end. This enabled the transmission rate to be determined with the help of a diagnosis program. Any data packets which might have been transmitted incorrectly could be indicated. The highest-possible transmission rate of 12 megabits/s was set.

The fundamental test, which commenced at the beginning of 2002 and is still in progress today, showed that only a relatively low number of cycles (420.000) resulted in the total failure of test item A, which, according to the competitors catalogue, should have functioned safely for at least 4.0 million cycles. Thus the real lifetime reaches only about 10% of the stated catalogue value.

Picture: Sliding application as the basis of the test structure

On the other hand test item B, the CFBUS.001, is still undergoing testing without any faulty data transmissions. So far, it has accomplished more than 14.0 million cycles.

4.28

Structure and materials


The main reason for the major differences in service life is the differing structural parameters of test item A and test item B (CFBUS.001), as well as the different materials used for producing the cables. The conductor insulation of the bus comprised of a foam material for all the test items. The electrical assets of this material ensured better transmission properties were achieved. A disadvantage of this material, however, was its weakness under reverse stresses. The forces which affect the bus pair should be absorbed by the element sheathing in order to alleviate the mechanical stress of the conductor insulation.

Number of double strokes

Test item A

CFBUS.001, Test item B

Highly-elastic element sheathing


For this reason, test item B (igus) was provided with a mechanically superior, extruded TPE inner, or element, gapfilling sheathing, in order to protect the bus pair against mechanical influences during the bending procedure. The element sheathing must be highly elastic. A mechanically inferior element sheathing made of inexpensive filling material only serves to make the bus pair round, just like frequently used fillers or banding. It is not able to protect the buses from the high degree of mechanical stress present in the chain. Tensile and compression forces which occur mainly influence those parts of the cable core in which there is a break in the element sheathing.
Test parameters Distance of travel: Speed, approx.: Acceleration, approx.: Radius, approx.: S = 5,0 m V = 3,5 m/s a = 7,5 m/s2 55 mm

which mechanically relieves the bus pair, fixes the cores in a defined position and bends. The extremely short pitch of the core strands and special cable also ensure that no great tensile or compression force has an effect on a long length of core.

UL and CSA approval


Chainflex CFBUS cables are now also available for all standard field bus systems, complete with UL and CSA approval and DESINA compliance. The highly abrasion-resistant, flameretardant TPE outer jacket is extruded onto the fully braided shield with an adjusted twisted angle in order to provide the cable with additional stability. The bus elements braided with a particularly short strand pitch are protected by means of a gap-filling, extruded TPE inner jacket. The bus parameters required are fulfilled by means of a choice of coordinated insulating materials and production procedures. As with all Chainflex cables, the new standard field bus cables of the CFBUS series are now available ex stock, without any cutting costs or extra charges for small quantities.

The sheathing of test item B (CFBUS.001) is on the one hand characterized by a mechanically superior, gusset-filled TPE element jacket, which mechanically relieves the bus pair, fixes the cores in a defined position and bends. The sheathing of test item B (CFBUS.001) is on the one hand characterized by a mechanically superior, gusset-filled TPE element jacket,

Product information CFBUS page 4.122

Position of the broken element jacket

Position of the broken core insulation


Fig. 3: A mechanically low-quality element jacket cant protect the bus pair against the high mechanical loads inside the Energy Chain.

4.29

Example 4: tested, tested, tested! CF98 with < 4xd!


For users of very small energy supply chains with mostly very narrow bending radiuses, the question for a suitable cable for very high stroke numbers has come up frequently in the past. At bending radiuses of less than 5xd, copper quickly reaches its physical limits, which necessitated the search for suitable substitute conductor materials or for fundamentally different conductor superstructures. Many series of tests with a variety of conductor superstructures and materials were performed in order to find out how cables must be manufactured in order to be able to endure several millions of bending operations in EChains, even at bending radiuses of less than 4xd.

Test set-up: Horizontal, short distance of travel


Test parameters Distance of travel: Speed, approx.: Acceleration, approx.: Radius, approx.: S = 0,8 m V = 1,5 m/s a = 0,5 m/s2 18 mm

Be nd ing rad ius =

4x

Product information CF98 page 4.96


4.30

Test 1: Inspection of four different cable designs


Four different cable constuctions has been analyzed: Test item A conductor with special conductor alloy Test item B conductor same as test item A, but in copper Test item C conductor in braided structure Test item D conductor in stranded construction This long-term inspection, which was carried out over a period of 2 years, provided the following results:

Test 2:
Two different cable designs were tested, whereby different core numbers and cross-sections were selected in comparison with test 1: Test item A conductor with special conductor alloy Test item B conductor in copper In this case, test item B was manufactured completely identical to test item A except for the conductor material. The test showed that not a single case of wire breakage could be detected for test item A even after 28 million double strokes. Test item B, however, only achieved approx. 1,4 million double strokes before complete destruction of the conductor was determined. This test also demonstrates that the alloy concept clearly surpasses the life of the copper conductor by more than 19 times and achieves these extraordinary results in the mechanically critical area of very small cross-sections!
Number of double strokes Cross d [mm] section 2x0,14 2x0,14 3,9 2,9 Testradius 4,6xd = 18 6,2xd = 18

Number of double strokes

Cross d [mm] section 7x0,20 7x0,20 7x0,25 7x0,25 5,8 5,6 7,3 7,3

Testradius 3,1xd = 18 3,2xd = 18 2,5xd = 18 2,5xd = 18

Test item A 47.434.277 450.000 Test item B 638.000 Test item C Test item D 2.350.000

Test item A 28.267.000 Test item B 1.450.000

Number of double strokes

Number of double strokes

Testradius

Test item A 3,1xd

Test item B 3,2xd

Test item C 2,5xd

Test item D 2,5xd Testradius Test item A 4,6xd Test item B 6,2xd

Conductivity of alloys
However, the outstanding mechanical properties of this alloy have to do with a reduced conductivity versus copper, which can be compensated by means of slightly increased cross-sections. This means that the cross-sections mentioned in the catalog meet the electrically defined cross-sections defined using the conductivity value. The conductor diameter of the alloyed conductor increases slightly compared to the conductor diameter of a copper conductor. This compromise results in a 10% greater external diameter for the CF98 series versus a comparable CF9 type, although the service life differences to be expected between the CF98 versus the CF9 speak for themselves and increase by a multiple factor in comparison with other so-called chain-suitable cables. As in the case of the CF9 series, further characteristics of the Chainflex CF98 include the highly abrasion-resistant, gusset-filled extruded TPE outer jacket, the oil resistance and the UV resistance as well as the absence of any PVC and halogen compounds. Especially in areas of application that only possess minimum construction space but also demand a large number of strokes, the igus cable offers an increased degree of operational safety and efficiency. Areas of application are available in the semiconductor and component parts industry, in the automation sector as well as in the automotive and bank sector. New possibilities of application can also be found in automatic doors for motor vehicles and trains as well as in automatic food and selfservice machines and in the packaging industry. 4.31

Example 5: tested! Dispersion and attenuation


Plastic fiber-optic cables in Energy Chains
Plastic fiber-optic cables have been introduced for data transmission in industrial applications due to their excellent interference-proof properties against electro-magnetic fields and further advantages such as the possibility of reducing dimensions and weights. The application as flexible link lines particularly in Energy supply chains places high demands on plastic fiber-optic cables. The most important characteristic values of a fiber-optic cable are dispersion and attenuation. Dispersion is the term used to describe the scattering of the travel time of the signal in the fiber-optic cable. In plastic fiber-optic cables this is essentially caused by the mode dispersion, which arises from the different travel times of individual light beams. Dispersion determines important transmission properties such as bandwidth, cut-off frequency or maximum bit rate. Significant changes in dispersion could not be ascertained in any of the investigations carried out. The industrial application of igus Chainflex-lines with plastic fiber-optic cables in supply chains for example is therefore unproblematic with regard to changes in dispersion. The second important characteristic property, attenuation, determines the maximum possible length of a transmission path. The attenuation of a plastic fiber, like that of the glass fiber, is also strongly dependent on the wavelength of the light used. For this reason all the investigations were carried out with a wavelength of 666nm. Depending on the output of the transmitter and the sensitivity of the receiver the operator has a certain "attenuation budget" available for the complete transmission path including all junction and transition regions. This attenuation budget (typical value approx. 20dB) must not be exceeded if a secure transmission of the data is to be guaranteed. For this reason it is of great interest to the user to know whether and to what extent increases in attenuation are to be expected for his particular application so that these can be taken into account in the compilation of his own attenuation budget. In addition to continuous bending stress, which is typical for operation in an Energy chain, further mechanical stresses that can occur during installation or operation must be taken into account. Thus, for example, relatively large tensile forces can occur when integrating the line into an Energy chain. The fixing of the lines at the ends of the energy chain using cable clamps leads to permanent transverse loads. The test of the behaviour under transverse load is carried out following DIN VDE 0472, Part 223. Since the cable clamps only exercise pressure in an area covering a few centimetres, increases in attenuation are relatively low. Attenuation under tensile load depends to a great extent of course on the composition of the line. Lines with integrated copper conductors or strain relief elements do not reveal a noticeable increase in attenuation until very much greater tensile forces are applied than is the case with pure fiber-optic cables.

4.32

Figure 1 represents test results for a Chainflex-line with 6 fiber-optic cables. The length of the test sample is 1m and the maximum tensile load 250 N.
Course of the increase in attenuation as a function of the tensile force

Figure 2: Course of the increase in attenuation as a function of the number of cycles.


Increase in attenuation as a function of the number n of travel movements

A in dB

Force F in N Number of cycle's n x 100.000

The tensile forces required to integrate fiber-optic cables in Energy Chains are usually much lower than 250 N. The increase in attenuation was 0,17 dB at maximum tensile force and disappeared completely after the tensile load was released. Thus no effect on attenuation should be expected. In the case of plastic fiber-optic cables that are bent very often, as is the case in applications with Energy Chains, then further influencing factors such as material fatigue, dulling of the materials, micro-cracks right through to complete fiber fracture must be feared, and their influence on attenuation can only be investigated in extensive practical tests such as those carried out by igus.

The excellent test results, shown in part here, of the Chainflex -lines must not be taken for granted, as investigations of fiber-optic cables from other manufacturers showed, some of which even failed with complete breaks in the fibers. The investigations revealed that Chainflex fiber-optic cables are not influenced in their function by mechanical loads such as tensile, transverse or bending stresses in Energy Chains. Therefore they are perfectly suitable for use in the sometimes rough industrial environments for the interference-proof transfer of information between drive and control elements of machines. Bibliography: [1] Plastic fiber-optic cables for flexible Energy supply systems: Bernfried Spth, Frank Blase

Product information FOC page 4.244


4.33

A in dB

Example 6: tested! Selection from test results


Since 1989, we have been working on the development of electrical cables.
Back then, many of our customers lost their faith in the solution with energy supply systems because the cables being used frequently failed. Core breakage, "corkscrews", jacket wear and breakage of the shields were substantial reasons for these failures. Our Chainflex product range was then created from this situation of emergency. And due to the fact that we knew very little about cables at that time, we had only one choice: Testing, testing, testing, testing, testing. Accordingly, we have since been making use of a firm principle: We almost always test our cables with a bending radius that is 30-50% less than the bending radius we mention in our catalog. We guarantee the quality requirement specified for our own products based on the production-process-accompanying sample tests that are carried out with at least 1 million reverse bending processes. During the subsequent inspection of the cable, this cable must be completely intact and, especially, none of the single wires must be broken. Newly developed types undergo considerably longer reverse bending processes in Energy Chains before a new Chainflex series is released.

Extensive database
Today, we have recourse to an extensive database with detailed information on the service life of our Chainflex cables which makes it possible for us to give you the information you need for your application.

Selection of test results from the igus-own technical training center in Cologne for the year 2000. 4.34

Example 7: tested! EMC tests


The "electromagnetic compatibility" of Chainflex cables
The subject of "electromagnetic compatibility (EMC)" is becoming increasingly important. For one thing, this is due to a increase in the electromagnetic interference fields in the long-distance range caused in particular by modern telecommunications and communication technology as well as in the local range caused by energy technology. On the other hand, the requirements for data transmission are also increasing. The signals are becoming more susceptible to interference and the electromagnetic environmental influencing factors more diverse. This can be especially problematic for the coupling between cables which, as is frequently the case in energy-conducting chains, are conducted on a parallel basis over a certain distance. A heavycurrent cable with interference acts as a producer of an electromagnetic interference field which, in turn, acts upon another cable, normally a signal cable, and then causes cableconducted interference there. Already several years ago, we therefore introduced electrical cables with fiber-optic cables made of glass that are also capable of being subjected to the mechanical stress in Energy Chains. Even the Chainflex cables with conventional copper conductors were tested with respect to their electromagnetic compatibility in an extensive, application-oriented test program. An asynchronous motor, for example, was therefore connected via an unshielded heavy-current cable (Chainflex CF30) to a frequency converter. This frequency converter with pulse width modulation becomes the generator of new spectral shares never existing previously in the primary or secondary networks. On a parallel basis with this heavy-current, Chainflex cables were also kept available for digital signal transmission in Energy Chains. Especially good results can be achieved here by the Chainflex CF12 cable which was specifically designed according to the EMC aspect. This cable possesses twisted-pair cores, the pairs of which are provided with a copper shield, as well as a total shield made of a steel braid in addition. Interference over a broad frequency range can therefore be effectively prevented as a result. The capacitive as well as the inductive coupling was also tested. In the case of the selected test conditions, it was determined that, even when the energy cables and signal cable touch one another over a longer distance, error-free data transmission is possible if a shielded Chainflex cable is used and this shield is grounded on both sides. In addition, tests were carried out in accordance with the existing standards on electromagnetic compatibility. These standards provide a general basis for determining the operating behavior of electrical devices that are repeatedly exposed to electrical interference. They were not introduced specifically for cables. In particular, tests with the "burst generator" were carried out. Here, fast transient interference signals are generated in pulse groups that simulate switching processes in particular. Such processes occur, e.g. during the interruption of inductive loads or during the bouncing of relay contacts. Here, too, the shielded Chainflex cables have proved their reliability.

Product information CF12 page 4.112


4.35

Example 8: tested, tested! Fibre optic cables run 76.000 km


Go 76.000 km or 1,5 times round the world with Chainflex fibre optic cables.
Users of data transmission systems (bus systems) with high data rates or long transmission lengths or even heavy EMC loads are relying on fibre optic cables more and more often. Many users today, however, are not conscious of the fact that the advantages that apply for fibre optic cables in general are even greater when Chainflex fibre optic cables are used in E-Chains. Data transmission systems on a copper basis usually have two basic disadvantages. 1. The maximum transmission lengths are greatly restricted by the transmission systems (between 5 and 50 m cable length depending on system and transmission frequency). 2. The copper-based cables used in moving energy supplies usually show an increase in attenuation values after some time at high cycle rates, which in turn have a negative effect on the maximum ranges. The case is completely different with data transmission or bus system-independent fibre optic cables made of glass. As well as being suitable for any transmission/bus system (providing the right converters are used), they have the following advantageous properties: 1. The transmission lengths are not restricted by the data transmission systems used and are depending on the type of fibre optic cable used several hundred metres long. 2. With Chainflex fibre optic cables, the increases in attenuation even at very high cycle rates in E-Chains are so low that the values are almost non-measurable, and most of the attenuation is to be found near the plug. The question of how greatly the attenuation behaviour of an igus Chainflex fibre optic cable changes has been examined using the following test set-up, which had not been concluded as the catalogue went to press (in 4/08).

Product information CFLG.2H page 4.160

4.36

Test parameters:
Test cable: Number of fibres: Type of fibre: Connector: Travel: Length of cable: Energy chain: Test radius: igus Chainflex CFLG.2HG.MF.50/125 2 Gradient fibre 50/125m 2 x ST Connector 2m 3m igus E-Chain series 15.015.100.0 11 x d

Taking into consideration that ST plugs have a mean insertion attenuation of 0,3 dB and a maximum insertion attenuation of 0,5 dB, the increase in attenuation of approx. 0,1-0,15 dB after more than 30 million movements in the E-Chain is absolutely negligible. Thus the cable has covered more than 76.000 km during the test. The lightwave length considered here is 850 nm.

Increase in attenuation as a function of the number of individual strokes

Attenuation in [dB]

Number of individual strokes in [MioH] Maximum permissible attenuation

4.37

Example 9: tested! Fast images


Fast images in industrial applications: USB, FireWire
The rising resolution and sampling rates of modern digital visual display systems are also inevitably accompanied by the rapid increase in the data quantities to be transmitted. Fast bus systems which find application for similar data quantities vailable in the consumer sector were taken from the industry particularly for this purpose. Here the typical representatives are bus systems such as FireWire (1394a and 1394b), USB (2.0), as well as Gigabit Ethernet or CameraLink. All these bus systems need special cables, which are offered in the consumer sector by numerous manufacturers at knocked-down prices. Many of these frequently preassembled cables are developed and manufactured only for static laying or minor mechanical stressing. Costly production losses would be inescapable, if such cables were used in industrial applications with all the known parameters such as chemicals, electro-magnetic and mechanical load, etc. These are not only "genuine" downtimes such as wire breakage or short circuits of the litz wires, but errors can be noticed gradually through alteration of the capacitive features with a reduction of the possible transmission rates and increased dampening. The use of substandard materials and a deficient mechanical structure in fiber optic cables can lead to murkiness of the fibers and thus also to reduced data rates. A genuine troubleshooting in bus cables is possible only with very expensive equipment and lots of time. Depending on the position of the damage, the errors may also occur only sporadically during operation and cannot be found once the facility stops. The good experiences in thousands of applications with classic field bus systems, e.g. Profibus, Interbus, DeviceNet, etc., and the desire of many customers for comparable cables also for the above-mentioned high-speed bus systems led igus to develop an own cable series, among others, with the following cable types: n CFBUS.055 for FireWire 1394a n CFBUS.065 and CFBUS.066 USB 2.0 n CFLG.2HG.MF. Fiber optic cable series for busindependent, long transmission stretches The main focus in the development was on mechanically stable cable designs in order to grant the capacitive, inductive and optical features over a high number of cycles. In the mechanical structure of the shields as well, a long service life was aimed at by material selection and special manufacturing processes.

4.38

Product information page 4.232

In the industrial environment, it is not only the electrical and mechanical features that play a role, but also the resistance to a great variety of media such as oils, coolants or the like. The seasoned outer jacket material TPE has already proved its durability in many thousands of applications in other igus cables. All cables are subject to ample tests in the igus laboratory; as there is no existing conclusive test procedure, the igus engineers chose a very pragmatic method.

Several industrial cameras traversed on a fast linear motor at a speed of 2 m/s, an acceleration of 5 m/s and a travel of 600 mm, while the bus cables moved continuously in the used E-Chain systems.

Test rig: 10 m CFBUS.055 FireWire (1394a) tested in an E-Chain of the B10.015.125 series with over 6 million movements with a FireWire 1394a camera. 10 m CFBUS.066 (USB 2.0) tested in an E-Chain of the B10.015.100 series with over 3,5 million movements with a USB 2.0 camera. 10 m CFLG.2HG.MF.50/125 tested in an E-Chain of the B10.015.075 series with over 3 million movements with a Fire-Wire 1394b camera with optical output. Despite the long cable lengths, particularly in USB and FireWire, no adverse effects on the picture quality could be determined even according to this stroke rate. This non-scientific, but practice-oriented test distinctly proves the industrial capability of these high-speed bus cables.

Stranded strain relief elements

Gel-filled, armored fiber sheath

Gusset-filled extruded PUR jacket

Cross section "Chainflex" fiber optic cable from igus.

This test is not complete and is continuing.

4.39

Example 10: tested! Light in the cold


Light in the cold igus gradient fibre glass cable in the deep freeze test
In the safe transmission of large amounts of data in bus systems at high speeds over long distances, the igus gradient fibre glass cable of the type CFLG.G has already become a standard in numerous applications in cranes. Insensitivity to electro-magnetic load and resistance to hard environmental influences enable the application together with energy supply cables in very long travels.

What happens in crane facilities in regions with extremely low temperatures? Does the maximum possible cable length of several hundred metres reduce through increase in dampening at low temperatures, or does the cable break in extreme applications, for example at -40 C? The sensitive glass fibres are conducted in a gel-filled hollow space. How does the gel behave in highly dynamic conditions and what happens in restarts after long downtimes? As no precise statement about this topic could be found in relevant technical journals, and as little was known particularly about the thermal features of the gel, igus, as part of its philosophy, undertook own tests to determine the reliable specifications for applications in E-Chain systems. For this task, the igus test laboratory was equipped with a freezer that can generate constant temperatures of -40 C and a test facility was mounted for long travels up to 7 m for a speed of 1,6 m/s and an acceleration up to 6 m/s. The igus gradient fibre glass cable CFLG.6G.50/125.TC was tested. The cable was tested with a length of about 15 m as loop in an igus E-ChainSystem 3500.125.200.0 with a radius of 200 mm. 4.40

Varied and extreme temperature curves thereby served for the simulation of environmental influences, particularly when the temperature plunged during downtimes from plus degrees to -40 C in the shortest time and the motion was restarted afterward. Under these application conditions, the dampening of the cable also should not rise above 3 dB at 850 nm wave length. After one million double strokes, which correspond to an operational performance of about 7000 kilometres, the maximum dampening is reached and still remains significantly below 3 dB. The measurements highlighted in the diagram reveal that distinct variations in temperature combined with the constant movement in the E-Chain have only minor effects on the dampening of the CFLG.6G.TC cable. The noticeable high initial dampening is attributed to the plugs used and also reflects the reality here because, in practice, 90 % of the cables used in automation are pluggable fibre optic cables.

Product information CFLG.G page 4.164

The test with the igus cable makes it quite clear that only realistic and absolutely very expensive tests can fetch clarity about the service life of cables.

Dampening of the fibres 1-6 of the CFLG.6G.50/125.T cable in two directions

Fibre no. 1, direction 1

Dampening in [dB] at 850 nm

Fibre no. 2, direction 1 Fibre no. 3, direction 1 Fibre no. 4, direction 1 Fibre no. 5, direction 1 Fibre no. 6, direction 1 Fibre no. 1, direction 2 Fibre no. 2, direction 2 Fibre no. 3, direction 2 Fibre no. 4, direction 2 Fibre no. 5, direction 2 Fibre no. 6, direction 2

Temperature in C (number of double strokes)

after 5 days after 5 days at rest at rest BEFORE AFTER restart restart

4.41

Example 11: tested! Completely turned


Chainflex cables for E-ChainSystem are designed for application in linear movements and their efficiency has been proved a million times. But industrial applications and their necessary motion sequences become increasingly complex, so that special cables are more and more required for torsional movements. The service life of the most differing constructions are yet harder to calculate for torsion applications, as no fixed sizes such as radii, travels or the like, are defined. Shielded cables however are very difficult in torsion applications. Braided shields are generally braided in the opposite direction. Whether a cable maintains the torsional demands is very strongly dependent on the application and type of installation. Unshielded cables, particularly all bundle-stranded Chainflex types, could be successfully used in many torsion applications. In torsional movements the shield litz wires are therefore drawn in one winding direction, and the other turned in the other winding direction. The woven arrangement and the entailing constriction of each winding direction lead to a quick breakage of the shield from the resulting expansion of the shield litz wires.

At igus, the emphasis is not only on technology but also on beautifully designed products. The TRC and TRE series both received the iF-Design-Award. 4.42

Product information CF ROBOT page 4.216

The new igus development of a twistable, shielded singlecore cable picks up on this point and ensures, due to its special design and understucture of the shield, that no forces at all or that only the smallest possible forces act on the shield wire. As the described test clearly shows, massive service life extension can, for example, be determined when compared to a CF310.250.01. Test rig: The new cable CF ROBOT was tested at the igus laboratory on a specially developed rig for torsion test. The torsion angle thereby amounts to 270 for a total cable length of about 2,5 m (tested in different versions of the Triflex R). Fitted for the test were: n 3 CF ROBOT cables 037 n 3 cables of the series CF310.250.01.UL n 3 cables of the series CF310.250.01 The detail inspection of the shield braid shows distinct damage on the shield wires. Picture 1: damaged overall shield sample of the braid version after 250.000 movements.

The analyzed samples (Picture 2) of the CF ROBOT (so far samples were taken after 250.000, 1,5 million and 3 million movements). 037 show no damage in the area of the cable or the overall shield even at above 3 million torsional movements of 270.

Picture 2: The CF ROBOT shows absolutely no damage after more than 3 million movements.

The detailed analyses (Picture 3) of the shield wires, buffer fibres, PTFE film and the cable show no apparent wear outs. The test is carried out further to determine the maximum service life of the cable.

igus test lab: The cables were tested in movements of 270.

The initial test sample of the CF310 with braided shield and the CF ROBOT were taken after 250.000 movements with a torsion angle of 270. The analyses (cable taken apart) were undertaken in three part areas respectively of the cable length. In the sample illustrated in Picture 1, distinct damage to the overall shield are noticeable in the upper third of the cable taken apart.

Picture 3: detail pictures of the CF ROBOT after more than 3.0 million movements of 270.

4.43

Example 12: tested, tested, tested! Service life comparision


Regular production inspections increase the operational reliability of machines. In addition to tests performed in the igus in-house laboratory, where new superstructural parts, materials, and customer requirements are constantly being inspected, igus also performs production-accompanying inspections. Next to batch tests, which immediately reveal any productionrelated defects and provide the user with maximum reliability, long-term inspections are performed again and again. These long-term inspections, which can take up to four years and emphasize the effort and expenditure required for such series of systematic tests are necessary if the constantly growing market demands are to be met. This also applies to the long-term inspection of the Chainflex servo cable families CF21.UL and CF27.D. These servo cables, which are based on a modular system and only differ in their inner and outer jacket materials in terms of production details, were tested for more than 2,5 years at a radius of 100 mm, a travel distance of approx. 8 m, an acceleration of approx. 6 m/s2, and a velocity of approx. 3,5 m/s. A core number / cross-section combination which is widely accepted in the field of mechanical engineering but also results in failures due to the extremely asymmetric setup in the case of many normal so-called chain-suitable cable superstructural parts was deliberately selected.

4.44

CF21.UL: overall stranding including the outer jacket without damage

CF27.D: overall stranding including the outer jacket without damage

CF21.40.10.02.01.UL: after more than 10 million bending movements, no shield wire breakages

CF27.40.10.02.01.D: after more than 10 million bending movements, no shield wire breakages

The test items, CF21.40.10.02.01.UL (4x4 mm2 + 2x1,0 mm2), and CF27.40.10.02.01.D (4x4 mm2 + 2x1,0 mm2), which were constantly monitored electrically during the test phase, were tested in continuous operation in a real chain-equipped system. Result: After more than 10 million individual strokes, the cables were disassembled into their individual parts and inspected. As can also be seen in the section photos, it was not possible to determine any wire breakages on the individual conductors or any changes on the insulations. Only slight traces of abrasion on the outer jacket which cannot result in any limitation of functions also show that the cable has completed a large number of strokes. Summary: The design philosophy, with gusset-filled extruded inner jacket and pressure-extruded outer jacket, clearly shows the long service life and definite advantages of these cables versus the commonly used cables most of which are designed with fillers and tapes.

Deliberately non-conforming chain filling in order to simulate a real application.

Product information CF21.UL page 4.170 CF27.D page 4.178

4.45

Example 13: tested live! Container crane at 50 m travel distance


In the crane engineering industry, energy supply systems prove their technical and economic strengths more and more frequently. Flexibility, variability, and space-saving installation are only a few of the most important criteria. An important building block of an energy supply system has to do with the cables. Here, users expect a high degree of operational reliability. In the Chainflex laboratory, igus cables undergo constant tests which can be used to obtain important information on the service life of a cable and to derive improvements for the future structural design of the cable. However, the situation becomes very exciting if you get the rare opportunity to remove cables from their real, tough applications and can inspect them. Current inspection The Chainflex cable CF9.60.05 has been used in container cranes for many years; in the case presented here with a total travel distance of approx. 47 m. An inspection contract commissioned by the owner-operator was to present a performance balance sheet after more than 40.000 chain kilometres and determine the date from which the next preventive maintenance work for the other equipment should be taken into account. Following the removal of the CF9.60.05, inspections were performed with the following objectives: 1. outer jacket, abrasion behaviour, other damage; 2. overall stranding, insulation behaviour of the individual cores; 3. litz wire structural design, number of any possibly individual broken wires which might be an indication of an early failure of the entire cable.

An igus energy supply system with a length of approx. 26 m in a stainless steel trough with middle band support.

4.46

The Energy Chain System was filled with many different igus Chainflex cables, e.g. the CF9.60.05 Result regarding 1: No or only barely measurable traces of abrasion could be detected on the highly abrasion-resistant TPE outer jacket. This means that a failure due to abrasion or jacket breakage despite extreme environmental factors (temperature differences, UV irradiation, etc.) is not to be expected. Result regarding 2: The overall stranding structure showed due to the gussetfilled extruded outer jacket no indications of fatigue and had not changed in its pitch length. Due to the large share of talc, no abrasion was determined between the TPE-insulated cores. The high-voltage tests also did not show any age-related changes. Result regarding 3: The cable was opened all the way to the copper conductor in the most stressed section of the radius. Here too, after more than 40.000 km, the inspection of the individual wires also showed no fatigue breakages which would indicate an early failure of the cable. To sum up, it can be said that this cable, which was used in a real crane application in the second trolley of an STS crane, is still completely intact even after more than 40.000 km and that preventive repair work is not required. The individual elements of the CF9 from the cable piece dissected for the test setup. An igus energy supply system with an approx. length of 26 m in a stainless steel trough with middle band support.

Product information CF9 page 4.80

A close-up of the completely intact copper conductor. The inspection performed over the entire length shows that the conductor is still completely intact and does have any individual wire breakages.

4.47

Example 14: tested! Comparison of sheathing materials in different oils


For years now, specially developed tests tailored to the individual requirements of igus customers have been used to obtain more meaningful results than would be conceivable if standard tests were used. The relatively generalised terms such as "oil-resistant" or "coolant-resistant" are little help in making the right selection in terms of sheathing material to be used for an application with oil, lubricant or coolant influence. Alongside the generally applicable tests according to e.g. DIN EN 60811-2-1 and IEC 60811-1-1, "everyday application conditions" are simulated as realistically as possible in a test set-up specially matching our customers' requirements. Thus, for example, the test samples are mounted in an energy chain that moves into an "oil bath" and then back out of it again. There is direct and alternating contact between the outer sheath and the medium to be tested and the air surrounding the energy chain or cable just as in a real application. After a test duration to be freely chosen or defined according to igus standard, the test samples can be tested in terms of changes in material characteristics e.g. by comparing material strength, elongation at tear and swelling with the values noted before the test started. This way, customers do not only get a statement referring to the different resistance of the various materials. In contrast to the material ageing otherwise common following the above-mentioned standards, an estimation of service life in the E-Chain application is also possible. If the test samples such as the external cables depicted do not achieve the prescribed test duration, we advise against use in the respective application.

Cracks in the outer sheathing of materials from competitors caused by the "use of oil" in E-Chains.

4.48

Example 15: tested! Completely twisted, take two.


The "torsion-resistant" requirement for cables for energy chains is not new, but is seldom defined exactly. So how is a statement such as "This cable is torsion-resistant up to 180 !" to be evaluated? This makes it all the more important to be able to deliver comparable and meaningful test results. In order to satisfy this requirement, the "torsion test bench" was developed according to igus standard. Here, various cable types are twisted to a prescribed cable length of 1 metre, which also corresponds to the distance between the fixed points. The degree of torsion can be freely chosen, and is defined individually according to the requirement made on the test specimen, whereby the test standard is 180 . After a prescribed number of double strokes or a negative electrical or mechanical test result, the respective test specimen is dissected, and the type and position of any damage can be determined exactly. The first Chainflex CFROBOT types were developed to series maturity on the basis of this igus standard test.

Product information CFROBOT page 4.216

The "torsion test bench" especially developed according to the igus standard. 4.49

ontrol cables

Minimum bending radius, moved [factor x d]

Torsion resistant

Chainflex types
Approvals and standards Oil-resistant Temperatur moved from/to [C] Chainflex cable Jacket Shield

a max. [m/s2]

v max. [m/s] unsupported

v max. [m/s] gliding

Control cables CF130.UL CF140.UL CF5 CF6 CF77.UL.D CF78.UL CF170.D CF180 CF2 CF9 CF10 CF9.UL CF10.UL CF98 CF99
PVC PVC PVC PVC PUR PUR PUR PUR PUR TPE TPE TPE TPE TPE TPE         7,5-10 7,5-15 6,8-7,5 6,8-7,5 6,8-7,5 6,8-7,5 7,5-10 7,5-15 5 5 5 5 5 4 4 -5/ +70 -5/ +70 -5/ +70 -5/ +70 -35/ +80 -35/ +80 -35/ +80 -35/ +80 -20/ +80 -35/ +100 -35/ +100 -35/ +100 -35/ +100 -35/ +90 -35/ +90                    3 3 10 10 10 10 3 3 10 10 10 10 10 10 10 2 2 5 5 5 5 2 2 5 6 6 6 6 6 6 20 20 80 80 80 80 20 20 80 100 100 100 100 100 100 4.52 4.56 4.60 4.64 4.68 4.70 4.72 4.74 4.76 4.80 4.84 4.88 4.92 4.96 4.98

Page

4.51

CF130.UL
PVC 7,5-10xd

PVC Control cable Chainflex CF130.UL


G for medium load requirements G PVC outer jacket G flame-retardant

Fine-wire stranded conductor

[C]
R

Temperature range moved

-5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles Minimum bending radius 7,5 x d with < 10 m travel, minimum bending radius 10 x d with 10 m travel

[C]
R

Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion Nominal voltage -20 C to +70 C, minimum bending radius 5 x d 3 m/s, 2 m/s 20 m/s2 Freely suspended travel distances, but also for gliding applications up to 50 m, Class 2 90, with 1 m cable length Number of cores < 12: 300/500 V Number of cores < 12 (0,25-0,34): 300/300 V Number of cores 12: 300/300 V (following DIN VDE 0245) Testing voltage Flame-retardant 2000 V (following DIN VDE 0281-2). According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Conductor Core insulation Core stranding Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded

Center element for high tensile stresses

Braiding in bundles around high-tensile center cord

Gusset-filled extruded

Silicon-free

Class 4.2.1

together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure. Core identification Cores < 0,5 mm2: colour code in accordance with DIN 47100 Cores 0,5 mm2: cores black with white numerals, one core green/yellow. Outer jacket
Image exemplary.

Low-adhesion mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0281 Part 5). Colour: Silver gray (similar to RAL 7001)

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.52

Price index

Class 4.2.1
UL/CSA CEI CE Lead free Style 10493 and 20200, 300 V, 60 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

CF130.UL
PVC 7,5-10xd

Typical application area


n for medium load requirements n without influence of oil n preferably indoor applications n especially for freely suspended travel distances, but also for gliding applications up to 50 m n wood/stone processing, packaging industry, supply system, handling, adjusting equipment

Chainflex CF130.UL for woodworking. E-Chain: E4/light

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF130 (for up to 10 cuts of the same type)

4.53

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF130.UL
PVC 7,5-10xd

PVC Control cable Chainflex CF130.UL


G for medium load requirements G PVC outer jacket G flame-retardant

Delivery program Part No. CF130.02.03.UL CF130.02.04.UL CF130.02.06.UL CF130.02.07.UL CF130.02.12.UL CF130.02.20.UL CF130.02.25.UL CF130.02.30.UL CF130.03.02.UL CF130.03.05.UL CF130.05.02.UL CF130.05.03.UL CF130.05.04.UL CF130.05.05.UL CF130.05.07.UL CF130.05.12.UL CF130.05.18.UL CF130.05.25.UL CF130.07.02.UL CF130.07.03.UL CF130.07.04.UL CF130.07.05.UL
Image exemplary.

Number of cores and conductor nominal cross section [mm2] 3 x 0,25 4 x 0,25 6 x 0,25 7 x 0,25 12 x 0,25 20 x 0,25 25 x 0,25 30 x 0,25 2 x 0,34 5 x 0,34 2 x 0,5 3 G 0,5 4 G 0,5 5 G 0,5 7 G 0,5 12 G 0,5 18 G 0,5 25 G 0,5 2 x 0,75 3 G 0,75 4 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 25 G 0,75 2 x 1,0 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0

External diameter approx. [mm] 4,5 5,5 6,0 6,5 8,5 10,5 11,5 12,5 4,5 5,5 5,5 6,0 6,5 7,0 8,0 9,5 12,0 13,5 6,0 6,5 7,0 7,5 8,5 10,5 13,0 15,5 6,0 7,0 7,5 8,0 9,5 11,5 14,0 17,0

Copper index [kg/km] 8 10 15 18 31 49 63 72 7 17 10 14 19 24 34 55 90 126 15 22 29 36 50 81 121 167 19 29 39 48 68 108 161 224

Weight [kg/km] 24 37 47 45 94 143 151 185 33 48 40 55 60 65 100 116 158 222 50 60 80 90 130 149 214 303 50 75 90 110 170 185 263 371 NEW* NEW* NEW* NEW* NEW* NEW*

CF130.07.07.UL CF130.07.12.UL CF130.07.18.UL CF130.07.25.UL CF130.10.02.UL CF130.10.03.UL CF130.10.04.UL CF130.10.05.UL

Class 4.2.1

CF130.10.07.UL CF130.10.12.UL CF130.10.18.UL CF130.10.25.UL

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

... no minimum order quantity


4.54
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 4.2.1
Delivery program Part No. CF130.15.02.UL CF130.15.03.UL CF130.15.04.UL CF130.15.05.UL CF130.15.07.UL CF130.15.12.UL CF130.15.18.UL CF130.15.25.UL CF130.25.03.UL CF130.25.04.UL CF130.25.07.UL CF130.25.12.UL CF130.40.03.UL CF130.60.04.UL CF130.60.05.UL Number of cores and conductor nominal cross section [mm ]
2

CF130.UL
PVC 7,5-10xd External diameter approx. [mm] 7,5 7,0 8,0 9,5 10,5 13,0 16,5 19,5 8,5 9,5 13,0 16,0 11,0 13,5 15,0 Copper index [kg/km] 29 44 58 72 101 162 242 350 72 96 168 265 115 230 288 70 90 120 140 210 263 386 541 116 180 350 406 200 360 418 Weight [kg/km]

2 x 1,5 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 3 G 2,5 4 G 2,5 7 G 2,5 12 G 2,5 3 G 4,0 4 G 6,0 5 G 6,0

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF130.05.02.UL in your desired length (0,5 m steps) CF130.UL Chainflex series .05 Code nominal cross section .02 Number of cores

Please use www.chainflex.eu/en/CF130 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF130 (for up to 10 cuts of the same type)

4.55

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF140.UL
PVC 7,5-15xd

PVC Control cable Chainflex CF140.UL


G for medium load requirements G PVC outer jacket G shielded G flame-retardant

Fine-wire stranded conductor

[C]
R

Temperature range moved

-5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles Minimum bending radius 7,5 x d with < 10 m travel, minimum bending radius 15 x d with 10 m travel

[C]
R

Temperature range fixed v max. unsupported/gliding a max. 3 m/s, 2 m/s 20 m/s2 Freely suspended travel distances, but also for gliding applications up to 50 m, Class 2 Nominal voltage Number of cores < 12: 300/500 V Number of cores 12: 300/300 V (following DIN VDE 0245) Testing voltage Flame-retardant Silicon-free Conductor Core insulation Core stranding 2000 V (following DIN VDE 0281-2). According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure. -20 C to +70 C, minimum bending radius 7,5 x d

Braiding in bundles around high-tensile center cord

Travel distance

Gusset-filled extruded

Bending-resistant braided copper shield

Pressure extruded

Class 4.2.1

Core identification

Cores < 0,5 mm2: colour code in accordance with DIN 47100 Cores 0,5 mm2: cores black with white numerals, one core green/yellow.

Inner jacket Overall shield


Image exemplary.

PVC mixture adapted to suit the requirements in Energy Chains. Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.56

Price index

Class 4.2.1
Outer jacket Low-adhesion mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0281 Part 5). Colour: Silver gray (similar to RAL 7001) UL/CSA CEI CE Lead free Style 10493 and 20200, 300 V, 60 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC

CF140.UL
PVC 7,5-15xd

Typical application area


n for medium load requirements n without influence of oil n preferably indoor applications n especially for freely suspended travel distances, but also for gliding applications up to 50 m n wood/stone processing, packaging industry, supply system, handling, adjusting equipment

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF140 (for up to 10 cuts of the same type)

4.57

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF140.UL
PVC 7,5-15xd

PVC Control cable Chainflex CF140.UL


G for medium load requirements G PVC outer jacket G shielded G flame-retardant

Delivery program Part No. CF140.02.12.UL CF140.03.05.UL CF140.05.03.UL CF140.05.05.UL CF140.05.18.UL CF140.05.36.UL CF140.07.03.UL CF140.07.04.UL CF140.07.05.UL CF140.07.07.UL CF140.07.12.UL CF140.07.18.UL CF140.07.25.UL CF140.10.02.UL CF140.10.03.UL CF140.10.04.UL CF140.10.05.UL CF140.10.07.UL CF140.10.12.UL CF140.10.18.UL CF140.10.25.UL CF140.15.03.UL
Image exemplary.

Number of cores and conductor nominal cross section [mm2] (12 x 0,25)C (5 x 0,34)C (3 G 0,5)C (5 G 0,5)C (18 G 0,5)C (36 G 0,5)C (3 G 0,75)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (18 G 0,75)C (25 G 0,75)C (2 x 1,0)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (25 G 1,0)C (3 G 1,5)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C (25 G 1,5)C (3 G 2,5)C (4 G 2,5)C

External diameter approx. [mm] 10,0 8,0 8,0 9,0 13,5 20,0 8,5 9,0 9,0 10,5 13,0 15,0 17,5 7,5 8,5 9,5 10,0 11,5 13,5 16,5 18,5 9,5 10,0 11,0 12,5 15,0 18,5 22,0 10,5 12,0

Copper index [kg/km] 69 42 37 52 130 273 48 57 66 84 130 179 256 33 44 55 77 107 162 227 322 69 89 105 135 215 339 480 98 174

Weight [kg/km] 111 80 87 130 232 493 90 130 150 170 220 289 414 84 130 150 170 200 243 407 481 150 180 220 260 407 467 703 171 250 NEW* NEW*

CF140.15.04.UL CF140.15.05.UL CF140.15.07.UL CF140.15.12.UL CF140.15.18.UL CF140.15.25.UL CF140.25.03.UL CF140.25.04.UL

Class 4.2.1

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

... no minimum order quantity


4.58
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 4.2.1
Order example: CF140.10.04.UL in your desired length (0,5 m steps) CF140.UL Chainflex series .10 Code nominal cross section .04 Number of cores

CF140.UL
PVC 7,5-15xd

Please use www.chainflex.eu/en/CF140 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

CF140.UL for automatic feeder units. E-Chain: Easy Chain

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF140 (for up to 10 cuts of the same type)

4.59

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF5
PVC 6,8-7,5xd

PVC Control cable Chainflex CF5


G for high load requirements G PVC outer jacket G oil-resistant G flame-retardant

New!
600V UL

Especially bendingresistant fine-wire stranded conductor

[C]
R

Temperature range moved

-5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles Minimum bending radius 6,8 x d with < 10 m travel, minimum bending radius 7,5 x d with 10 m travel

[C]
R

Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 90, with 1 m cable length -20 C to +70 C, minimum bending radius 4 x d

Center element for high tensile stresses

UV

UV-resistant Nominal voltage Testing voltage Oil

Medium 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2

Braiding in bundles around high-tensile center cord

Gusset-filled extruded, oil-proof PVC mixture

Flame-retardant Silicon-free Conductor Core insulation

According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Cores < 0,5 mm2: Mechanically high-quality PP mixture. Cores 0,5 mm2: Mechanically high-quality PVC mixture (following DIN VDE 0207 Part 4).

Class 5.3.2

Core stranding

Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Core identification
Image exemplary.

Cores < 0,5 mm2: colour code in accordance with DIN 47100 Cores 0,5 mm2: cores black with white numerals, one

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...
* New in this catalog.

4.60

Price index

Class 5.3.2
core green/yellow. Outer jacket Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Moss green (similar to RAL 6005) UL/CSA < 0,5 mm2: Style 10492 and 2570, 600 V, 80 C 0,5 mm2: Style 11113 and 2570, 600 V, 80 C CEI CE Lead free Clean room Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 2, material/cable tested by IPA according to ISO standard 14644-1

CF5
PVC 6,8-7,5xd

Typical application area


n for high load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF5 (for up to 10 cuts of the same type)

4.61

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF5
PVC 6,8-7,5xd

PVC Control cable Chainflex CF5


G for high load requirements G PVC outer jacket G oil-resistant G flame-retardant

Delivery program Part No. CF5.02.36 CF5.03.15 CF5.03.18 CF5.03.25 CF5.05.02 CF5.05.03 CF5.05.05 CF5.05.07 CF5.05.12 CF5.05.18 CF5.05.25 CF5.05.30 CF5.07.03 CF5.07.04 CF5.07.05 CF5.07.07 CF5.07.12 CF5.07.18 CF5.07.25 CF5.07.36 CF5.07.42
Image exemplary.

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 15,0 10,5 11,5 13,5 6,0 6,0 7,0 8,0 11,0 12,5 16,5 17,5 6,5 7,0 7,5 9,0 12,5 15,0 17,5 22,0 23,5 6,5 7,0 9,0 9,5 13,5 16,5 19,5 7,5 7,5 8,5 10,5 15,0 19,0 21,5 26,0

Copper index [kg/km] 95 52 64 88 10 15 24 34 58 86 121 144 22 29 36 50 86 130 181 259 302 29 39 48 68 116 173 241 44 58 72 101 173 260 361 518

Weight [kg/km] 275 135 175 235 34 42 72 77 158 230 310 402 63 72 85 108 240 322 432 564 610 62 85 100 145 260 450 590 95 120 170 220 320 550 810 980

36 x 0,25 15 x 0,34 18 x 0,34 25 x 0,34 2 x 0,5 3 G 0,5 5 G 0,5 7 G 0,5 12 G 0,5 18 G 0,5 25 G 0,5 30 G 0,5 3 G 0,75 4 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 25 G 0,75 36 G 0,75 42 G 0,75 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 36 G 1,5

CF5.10.03 CF5.10.04 CF5.10.05 CF5.10.07 CF5.10.12 CF5.10.18 CF5.10.25 CF5.15.03 CF5.15.04

Class 5.3.2

CF5.15.05 CF5.15.07 CF5.15.12 CF5.15.18 CF5.15.25 CF5.15.36

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity


4.62
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 5.3.2
Delivery program Part No. CF5.25.04 CF5.25.05 CF5.25.07 CF5.25.12 CF5.25.18 CF5.25.25 Number of cores and conductor nominal cross section [mm ]
2

CF5
PVC 6,8-7,5xd External diameter approx. [mm] 11,5 12,0 14,5 23,5 27,5 34,5 Copper index [kg/km] 120 168 288 432 600 250 340 667 970 1366 96 Weight [kg/km]

5 G 2,5 7 G 2,5 12 G 2,5 18 G 2,5 25 G 2,5

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF5.07.03 in your desired length (0,5 m steps) CF5 Chainflex series .07 Code nominal cross section .03 Number of cores

Delivery time 24h or today*


* Delivery time means time until shipping of goods

CF5/CF6 for shelf control units: long travel in the longitudinal axis. E-Chain: Series E4/00 with igus guide trough out of steel

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF5 (for up to 10 cuts of the same type)

4.63

Fax +49-2203-96 49-222

Please use www.chainflex.eu/en/CF5 for your online order.


Tel. +49-2203-96 49-0

Control cable

4 G 2,5

200

CF6
PVC 6,8-7,5xd

PVC Control cable Chainflex CF6


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

New!
600V UL

Especially bendingresistant fine-wire stranded conductor

[C]
R

Center element for high tensile stresses

[C]
R

Temperature range moved Temperature range fixed v max. unsupported/gliding a max.

-5 C to +70 C, minimum bending radius 6,8 x d with < 10 m travel; minimum bending radius 7,5 x d with 10 m travel -20 C to +70 C, minimum bending radius 4 x d 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 Medium 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Cores < 0,5 mm2: Mechanically high-quality PP mixture. Cores 0,5 mm2: Mechanically high-quality PVC mixture (following DIN VDE 0207 Part 4). Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure. Cores < 0,5 mm2: colour code in accordance with DIN 47100 Cores 0,5 mm2: cores black with white numerals, one core green/yellow. PVC mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical.

Braiding in bundles around high-tensile center cord

Travel distance

UV

UV-resistant Nominal voltage Testing voltage

Gusset-filled extruded

Oil

Highly flexible braided copper shield

Flame-retardant Silicon-free Conductor

Pressure extruded, oil-resistent PVC blend

Core insulation

Core stranding

Class 5.3.2

Core identification

Inner jacket Overall shield

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...
* New in this catalog.

4.64

Price index

Class 5.3.2
Outer jacket Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Moss green (similar to RAL 6005) UL/CSA < 0,5 mm2: Style 10492 and 2570, 600 V, 80 C 0,5 mm2: Style 11113 and 2570, 600 V, 80 C CEI CE Lead free Clean room Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1

CF6
PVC 6,8-7,5xd

Typical application area


n for high load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF6 (for up to 10 cuts of the same type)

4.65

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF6
PVC 6,8-7,5xd

PVC Control cable Chainflex CF6


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Delivery program Part No. CF6.02.04 CF6.02.24(3) CF6.03.05 CF6.05.02 CF6.05.05 CF6.05.07 CF6.05.09 CF6.05.12 CF6.05.18 CF6.05.24(3) CF6.07.03 CF6.07.04 CF6.07.05 CF6.07.07 CF6.07.12 CF6.07.18 CF6.07.24 CF6.10.03 CF6.10.04 CF6.10.05
Image exemplary.
(3)

Number of cores and conductor nominal cross section [mm2] (4 x 0,25)C (24 x 0,25)C (5 x 0,34)C (2 x 0,5)C (5 G 0,5)C (7 G 0,5)C (9 G 0,5)C (12 G 0,5)C (18 G 0,5)C (24 G 0,5)C (3 G 0,75)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (18 G 0,75)C (24 G 0,75)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (24 G 1,0)C (3 G 1,5)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C (25 G 1,5)C (36 G 1,5)C (4 G 2,5)C

External diameter approx. [mm] 7,5 14,0 8,0 7,0 8,5 10,0 11,5 13,0 15,0 17,5 8,0 8,5 9,0 10,5 14,0 17,5 19,5 8,5 9,0 9,5 12,0 15,0 19,0 21,0 9,0 10,0 10,0 12,0 17,0 21,5 23,5 30,0 13,0

Copper index [kg/km] 31 122 41 31 48 63 77 93 120 190 52 54 73 93 138 204 250 61 75 87 113 171 261 307 81 85 106 153 232 367 492 630 135

Weight [kg/km] 72 265 106 65 114 142 180 206 276 405 110 120 150 190 264 410 466 103 115 170 217 313 470 588 155 170 190 270 411 637 819 1241 275 NEW* NEW*

CF6.10.07 CF6.10.12 CF6.10.18 CF6.10.24(3) CF6.15.03 CF6.15.04 CF6.15.05 CF6.15.07

Class 5.3.2

CF6.15.12 CF6.15.18 CF6.15.25 CF6.15.36 CF6.25.04

The Chainflex types marked with a (3) refer to cables that are based on a bundling of 4 cores each. Due to their excellent electrical properties (star-quad with especially minimum crosstalk), these cables can virtually be used in all cases in which otherwise twisted-pair cables are required. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

... no minimum order quantity


4.66
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 5.3.2
Order example: CF6.15.12 in your desired length (0,5 m steps) CF6 Chainflex series .15 Code nominal cross section .12 Number of cores

CF6
PVC 6,8-7,5xd

Please use www.chainflex.eu/en/CF6 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

CF5 and CF6 control cable (green) as well as CF211 measuring system cable (gray) in a screwing station of a motor factory. E-Chain: System E4/00 with Chainfix Clip Strain Relief Devices

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF6 (for up to 10 cuts of the same type)

4.67

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF77.UL.D
PUR 6,8-7,5xd

PUR Control cable Chainflex CF77.UL.D


G for high load requirements G PUR outer jacket G oil-resistant and coolant-resistant G flame-retardant G notch-resistant G PVC-free/halogen-free
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion -35 C to +80 C, minimum bending radius 6,8 x d with < 10 m travel distance, minimum bending radius 7,5 x d -40 C to +80 C, minimum bending radius 4 x d 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 90, with 1 m cable length Medium Number of cores < 12: 300/500 V Number of cores < 12 (0,25-0,34): 300/300 V Number of cores 12: 300/300 V (following DIN VDE 0245) 2000 V (following DIN VDE 0281-2) Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3 MUD-resistant following NEK 606 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992) Following EN 50267-2-1 Fine-wire stranded conductor consisting of bare copper wires (following EN 60228) Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100. Cores 0,5 mm2: cores black with white numerals, one core green-yellow. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040) Style 10493 and 20233, 300 V, 80 C Following CEI 20-35

[C]
R

Fine-wire stranded conductor

Center element for high tensile stresses

UV-resistant Nominal voltage

Testing voltage Oil Offshore Flame-retardant Silicon-free


Gusset-filled extruded

Braiding in bundles around high-tensile center cord

Halogen-free Conductor Core insulation Core stranding

Class 5.3.3

Core identification Outer jacket

UL/CSA
Image exemplary.

CEI

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.68

Price index

Class 5.3.3
CE DESINA Lead free Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC

CF77.UL.D
PUR 6,8-7,5xd

Typical application area


n for high load requirements n almost unlimited resistance to oil n indoor and outdoor applications with average sun radiation n especially for freely suspended and gliding travel distances up to 100 m n Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector Delivery program Part No. CF77.UL.02.04.D CF77.UL.05.04.D CF77.UL.05.05.D CF77.UL.05.12.D CF77.UL.05.18.D CF77.UL.05.25.D CF77.UL.05.30.D CF77.UL.07.03.D CF77.UL.07.04.D CF77.UL.07.05.D CF77.UL.07.07.D CF77.UL.07.12.D CF77.UL.07.18.D CF77.UL.07.20.D CF77.UL.07.36.D CF77.UL.10.02.D CF77.UL.10.03.D CF77.UL.10.04.D CF77.UL.10.05.D CF77.UL.10.07.D CF77.UL.10.12.D CF77.UL.10.18.D CF77.UL.10.25.D CF77.UL.15.03.D CF77.UL.15.04.D CF77.UL.15.05.D CF77.UL.15.07.D CF77.UL.15.12.D CF77.UL.15.18.D CF77.UL.15.25.D CF77.UL.25.04.D CF77.UL.25.05.D CF77.UL.25.07.D CF77.UL.40.04.D(1) Number of cores and conductor nominal cross section [mm ] 4 x 0,25 4 G 0,5 5 G 0,5 12 G 0,5 18 G 0,5 25 G 0,5 30 G 0,5 3 G 0,75 4 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 20 G 0,75 36 G 0,75 2 x 1,0 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 4 G 2,5 5 G 2,5 7 G 2,5 4 G 4,0
2

External diameter approx. [mm] 5,5 6,0 6,5 10,0 12,0 13,5 14,5 6,0 6,5 7,0 8,0 11,5 13,5 14,0 18,5 6,0 6,5 7,0 7,5 8,5 11,5 14,5 17,0 7,0 7,5 8,0 10,0 14,0 17,0 19,5 9,0 10,5 12,5 11,5

Copper index [kg/km] 10 19 24 57 86 119 143 21 28 35 49 84 126 140 252 20 29 39 49 68 116 174 240 42 55 69 96 165 260 360 91 120 168 154

Weight [kg/km] 34 48 55 128 188 244 297 52 61 71 100 183 247 277 500 52 61 75 91 112 222 321 406 81 99 117 164 290 397 555 145 179 253 242 NEW*

NEW*

NEW*

NEW* NEW*

(1) Delivery time upon inquiry * New in this catalog. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF77 (for up to 10 cuts of the same type) 4.69

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF78.UL
PUR 6,8-7,5xd

PUR Control cable Chainflex CF78.UL


G for high load requirements G PUR outer jacket G oil-resistant and coolant-resistant G flame-retardant G notch-resistant G PVC-free/halogen-free
Temperature range moved
[C]
R

Fine-wire stranded conductor

-35 C to +80 C, minimum bending radius 6,8 x d with < 10 m travel distance, minimum bending radius 7,5 x d with 10 m travel distance -40 C to +80 C, minimum bending radius 4 x d 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 Medium Number of cores < 12: 300/500 V Number of cores < 12 (0,25-0,34): 300/300 V Number of cores 12: 300/300 V (following DIN VDE 0245) 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3 MUD-resistant following NEK 606 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1 Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure. Cores < 0,5 mm2: Colour code in accordance with DIN 47100. Cores 0,5 mm2: cores black with white numerals, one core green-yellow. PUR mixture adapted to suit the requirements in Energy Chains. Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040)

Temperature range fixed v max. unsupported/gliding a max. Travel distance UV-resistant Nominal voltage

Braiding in bundles around high-tensile center cord

Testing voltage
Gusset-filled extruded

Oil Offshore

Biegefester GeflechtKupferschirm

Flame-retardant Silicon-free Halogen-free

Mit Druck extrudiert

Conductor Core insulation Core stranding

Class 5.3.3

Core identification

Inner jacket Overall shield Outer jacket


Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.70

Price index

Class 5.3.3
UL/CSA CEI CE Lead free Style 10493 and 20233, 300 V, 80 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC

CF78.UL
PUR 6,8-7,5xd

Typical application area


n for high load requirements n almost unlimited resistance to oil n indoor and outdoor applications with average sun radiation n especially for freely suspended and gliding travel distances up to 100 m n Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector Delivery program Part No. CF78.UL.05.04 CF78.UL.05.05 CF78.UL.05.07 CF78.UL.05.09 CF78.UL.05.12 CF78.UL.05.18 CF78.UL.05.24 CF78.UL.07.03 CF78.UL.07.04 CF78.UL.07.05 CF78.UL.07.07(1 CF78.UL.07.12 CF78.UL.07.18(1) CF78.UL.10.03 CF78.UL.10.04 CF78.UL.10.05 CF78.UL.10.07 CF78.UL.10.12 CF78.UL.10.18(1) CF78.UL.10.25 CF78.UL.15.03 CF78.UL.15.04 CF78.UL.15.05 CF78.UL.15.07 CF78.UL.15.12 CF78.UL.25.04 CF78.UL.25.05(1) CF78.UL.25.07 CF78.UL.40.04(1) Number of cores and conductor nominal cross section [mm ]
2

External diameter approx. [mm] 8,0 8,5 9,5 10,5 12,5 14,0 15,5 8,0 8,5 9,5 10,5 13,5 15,5 8,5 9,0 9,5 11,0 14,1 17,0 19,5 9,5 10,0 10,5 12,5 15,5 11,5 12,5 14,5 15,0

Copper index [kg/km] 32 38 56 68 88 125 160 35 47 57 77 125 175 48 58 71 94 155 220 315 65 80 98 131 215 123 150 207 189

Weight [kg/km] 77 88 117 144 198 268 334 82 94 119 153 252 337 101 116 137 179 299 412 535 126 145 172 225 370 205 245 330 322 NEW* NEW* NEW*

(4 G 0,5)C (5 G 0,5)C (7 G 0,5)C (9 G 0,5)C (12 G 0,5)C (18 G 0,5)C (24 G 0,5)C (3 G 0,75)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (18 G 0,75)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (25 G 1,0)C (3 G 1,5)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (4 G 2,5)C (5 G 2,5)C (7 G 2,5)C (4 G 4,0)C

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF78 (for up to 10 cuts of the same type) 4.71

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF170.D
PUR 7,5-10xd

PUR Control cable Chainflex CF170.D


G for medium load requirements G PUR outer jacket G oil-resistant and coolant-resistant G PVC-free/halogen-free G low-temperature-flexible

Fine-wire stranded conductor

Temperature range moved


[C]
R

-35 C to +80 C, minimum bending radius 7,5 x d with < 10 m travel distance, minimum bending radius 10 x d with 10 m travel distance

Temperature range fixed v max. unsupported/gliding a max. Travel distance UV-resistant Nominal voltage Testing voltage Oil Offshore Silicon-free Halogen-free 20 m/s2 Freely suspended travel distances, Class 1 Medium 300/500 V (following DIN VDE 0245) 2000 V (following DIN VDE 0281-2) Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3. MUD-resistant following NEK 606 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Core insulation Core stranding Core identification Mechanically high-quality TPE mixture. Cores stranded in layers with short pitch length. Cores black with white numerals, one core green-yellow. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040) CE DESINA Lead free Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC -40 C to +80 C, minimum bending radius 5 x d 3 m/s, 2 m/s

Center element for high tensile stresses

Braiding in layers with extremely short pitch

Gusset-filled extruded

Conductor

Class 4.1.3

Outer jacket

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.72

Price index

Class 4.1.3
Typical application area
n for medium load requirements n indoor and outdoor applications without direct sun radiation n especially for freely suspended travel distances, but also for gliding applications up to 20 m n Machining units/machine tools, low temperature applications n almost unlimited resistance to oil

CF170.D
PUR 7,5-10xd

Delivery program Part No. CF170.05.12.D CF170.05.18.D CF170.05.30.D CF170.07.03.D CF170.07.05.D CF170.07.07.D CF170.07.12.D CF170.07.18.D CF170.07.20.D CF170.10.03.D CF170.10.04.D CF170.10.05.D CF170.10.07.D CF170.10.12.D CF170.10.18.D CF170.10.25.D CF170.15.03.D CF170.15.04.D CF170.15.05.D CF170.15.07.D CF170.15.12.D CF170.15.18.D CF170.15.25.D CF170.25.04.D CF170.25.05.D CF170.25.07.D CF170.40.04.D CF170.60.04.D CF170.100.04.D

Number of cores and conductor nominal cross section [mm2] 12 G 0,5 18 G 0,5 30 G 0,5 3 G 0,75 5 G 0,75 7 G 0,75 12 G 0,75 18 G 0,75 20 G 0,75 3 G 1,0 4 G 1,0 5 G 1,0 7 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 3 G 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5 4 G 2,5 5 G 2,5 7 G 2,5 4 G 4,0 4 G 6,0 4 G 10,0

External diameter approx. [mm] 9,0 11,5 14,0 6,5 7,5 8,5 10,0 12,5 13,5 7,0 7,5 8,0 9,5 10,5 13,5 16,0 7,5 8,0 8,5 10,5 13,0 15,0 19,0 10,0 10,5 13,0 12,0 14,0 18,0

Copper index [kg/km] 58 86 144 22 36 50 86 130 144 29 37 48 67 118 173 240 43 58 68 101 173 259 360 96 114 168 154 230 384

Weight [kg/km] 125 180 280 50 70 100 160 230 288 55 61 85 130 170 290 390 72 90 106 180 270 390 540 150 177 280 220 320 530

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF170.10.05.D in your desired length (0,5 m steps) CF170.D Chainflex series .10 Code nominal cross section .05 Number of cores

Please use www.chainflex.eu/en/CF170D for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF170D (for up to 10 cuts of the same type) 4.73

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF180
PUR 7,5-15xd

PUR Control cable Chainflex CF180


G for medium load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G PVC-free/halogen-free G low-temperature-flexible
Temperature range moved
[C]
R

Fine-wire stranded conductor

-35 C to +80 C, minimum bending radius 7,5 x d with < 10 m travel distance, minimum bending radius 15 x d with 10 m travel distance

Temperature range fixed v max. unsupported/gliding a max. Travel distance -40 C to +80 C, minimum bending radius 5 x d 10 m/s, 5 m/s 20 m/s2 Freely suspended travel distances, Class 1 Medium 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3. MUD-resistant following NEK 606 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Fine-wire stranded conductor consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. Cores stranded in layers with short pitch length. Cores black with white numerals, one core green-yellow. PUR mixture adapted to suit the requirements in Energy Chains. Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Window gray (similar to RAL 7040) Following 2006/95/EG Following EC (RoHS) 2002/95/EC

Center element for high tensile stresses

Braiding in layers with extremely short pitch

UV-resistant Nominal voltage Testing voltage Oil Offshore

Gusset-filled extruded

Bending-resistant braided copper shield

Silicon-free Halogen-free
Pressure extruded, halogen-free PUR blend

Conductor Core insulation Core stranding Core identification Inner jacket

Class 4.1.3

Overall shield Outer jacket

CE Lead free

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.74

Price index

Class 4.1.3
Typical application area
n n n n n for medium load requirements almost unlimited resistance to oil indoor and outdoor applications without direct sun radiation especially for freely suspended travel distances, but also for gliding applications up to 20 m Machining units/machine tools, low temperature applications

CF180
PUR 7,5-15xd

Delivery program Part No. CF180.05.18 CF180.07.03 CF180.07.05 CF180.07.12 CF180.07.18 CF180.10.05 CF180.10.18 CF180.15.03 CF180.15.04 CF180.15.07 CF180.25.04 CF180.25.05 CF180.25.07

Number of cores and conductor nominal cross section [mm2] (18 G 0,5)C (3 G 0,75)C (5 G 0,75)C (12 G 0,75)C (18 G 0,75)C (5 G 1,0)C (18 G 1,0)C (3 G 1,5)C (4 G 1,5)C (7 G 1,5)C (4 G 2,5)C (5 G 2,5)C (7 G 2,5)C

External diameter approx. [mm] 11,5 7,5 8,5 11,0 13,0 9,5 14,0 8,5 9,5 11,5 10,5 11,5 13,5

Copper index [kg/km] 121 40 61 133 176 75 238 67 85 146 130 165 225

Weight [kg/km] 200 71 95 186 255 120 317 104 129 202 179 218 295

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF180.07.05 in your desired length (0,5 m steps) CF180 Chainflex series .07 Code nominal cross section .05 Number of cores

Please use www.chainflex.eu/en/CF180 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF180 (for up to 10 cuts of the same type) 4.75

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF2
PUR 5xd

PUR Control cable Chainflex CF2


G for maximum load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G flame-retardant G notch-resistant G hydrolysis-resistant and microbe-resistant
[C]
R

Extremely high flexible special conductor

Temperature range moved Temperature range


R

-20 C to +80 C, minimum bending radius 5 x d -40 C to +80 C, minimum bending radius 4 x d 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3

[C]

Center element for high tensile stresses

fixed v max. unsupported/gliding a max.

Braiding in bundles around high-tensile center cord

Travel distance

UV

UV-resistant Nominal voltage Testing voltage Oil

High 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3

Gusset-filled, pressure extruded

Highly flexible braided copper shield

Offshore Flame-retardant Silicon-free Conductor Core insulation

MUD-resistant following NEK 606 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Cores < 0,5 mm2: Mechanically high-quality PP mixture. Cores 0,5 mm2: Mechanically high-quality PVC mixture (following DIN VDE 0207 Part 4).

Pressure extruded PUR blend

Class 6.3.3

Core stranding

Number of cores < 12: cores stranded in a layer with short pitch length < 0,5 mm2 : PP mixture Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Core identification
Image exemplary.

Cores < 0,5 mm2: colour code in accordance with DIN 47100 Cores 0,5 mm2: cores black with white numerals, one core green/yellow.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.76

Price index

Class 6.3.3
Inner jacket Overall shield Outer jacket PVC mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Anthracite gray (similar to RAL 7016) UL/CSA < 0,5 mm2: Style 10467 and 20317, 300 V, 80 C 0,5 mm2: Style 1007 and 20317, 300 V, 80 C 0,5 mm2: Style 1011 and 20234, 600 V, 80 C CEI CE Lead free Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

CF2
PUR 5xd

Typical application area


n for maximum load requirements n almost unlimited resistance to oil n indoor and outdoor applications n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes, refrigerating sector

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF2 (for up to 10 cuts of the same type)

4.77

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF2
PUR 5xd

PUR Control cable Chainflex CF2


G for maximum load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G flame-retardant G notch-resistant G hydrolysis-resistant and microbe-resistant
Delivery program Part No. CF2.01.04 CF2.01.08 CF2.01.12 CF2.01.18 CF2.01.24(3) CF2.01.36 CF2.01.48 CF2.02.04 CF2.02.08 CF2.02.18 CF2.02.24(3) CF2.02.48 CF2.05.05(1) CF2.05.07(1) CF2.05.09(1) CF2.05.12
(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 6,0 8,0 9,0 10,0 11,5 14,0 17,0 7,0 8,0 13,0 14,0 20,0 10,5 13,0 15,0 18,0 22,0 23,0 10,0 10,0 14,0 19,0 25,0 10,0 12,0 14,0 20,0 26,0 11,0 16,0 23,0

Copper index [kg/km] 17 29 49 53 65 88 135 24 41 96 120 230 64 82 97 145 192 238 51 57 102 183 302 63 91 120 213 363 85 163 289

Weight [kg/km] 40 65 101 125 135 200 310 53 83 190 220 450 170 210 260 390 520 620 140 160 240 440 720 150 200 260 480 780 190 340 650

(4 x 0,14)C (8 x 0,14)C (12 x 0,14)C (18 x 0,14)C (24 x 0,14)C (36 x 0,14)C (48 x 0,14)C (4 x 0,25)C (8 x 0,25)C (18 x 0,25)C (24 x 0,25)C (48 x 0,25)C (5 G 0,5)C (7 G 0,5)C (9 G 0,5)C (12 G 0,5)C (18 G 0,5)C (24 G 0,5)C (3 G 0,75)C (4 G 0,75)C (7 G 0,75)C (12 G 0,75)C (24 G 0,75)C (3 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (24 G 1,0)C (3 G 1,5)C (7 G 1,5)C (12 G 1,5)C

CF2.05.18(1) CF2.05.24 / CF2.07.03(1) CF2.07.04(1) CF2.07.07(1)


Image exemplary.
(3) (1)

CF2.07.12 CF2.10.03 CF2.10.07

(1)

CF2.07.24(3)/(1)
(1)

CF2.10.05(1)
(1)

CF2.10.12(1) CF2.10.24(1) CF2.15.03(1)

Class 6.3.3

CF2.15.07(1) CF2.15.12(1)

(1) Delivery time upon inquiry Deliverable alternative: CF10, CF10.UL, CF78.UL The Chainflex types marked with a (3) refer to cables that are based on a bundling of 4 cores each. Due to their excellent electrical properties (star-quad with especially minimum crosstalk), these cables can virtually be used in all cases in which otherwise twisted-pair cables are required. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity


4.78
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.3.3
Order example: CF2.10.24 in your desired length (0,5 m steps) CF2 Chainflex series .10 Code nominal cross section .24 Number of cores

CF2
PUR 5xd

Please use www.chainflex.eu/en/CF2 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

CF2 cables are resistant to oil and coolants. E-Chain: System E4/00

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF2 (for up to 10 cuts of the same type)

4.79

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF9
TPE 5xd

TPE Control cable Chainflex CF9


G for maximum load requirements G TPE outer jacket G oil-resistant G bio-oil-resistant G PVC-free/halogen-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant

Extremely high flexible special conductor

[C]
R

Temperature range moved Temperature range


R

-35 C to +100 C, minimum bending radius 5 x d -40 C to +100 C, minimum bending radius 3 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 90, with 1 m cable length

[C]

fixed v max. unsupported/gliding a max. Travel distance Torsion

Center element for high tensile stresses

UV
Braiding in bundles around high-tensile center cord

UV-resistant Nominal voltage Testing voltage Oil Silicon-free

High 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992).

Gusset-filled extruded, halogenfree TPE mixture

Hal

Halogen-free Conductor

Following EN 50267-2-1. Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation

Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Class 7.4.4

Core stranding

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.80

Price index

Class 7.4.4
Core identification Cores < 0,75 mm2: colour code in accordance with DIN 47100 Cores 0,75 mm2: cores black with white numerals, one core green/yellow. CF9.02.03.INI: CF9.03.04.INI: CF9.03.05.INI: CF9.03.16.07.03.INI: (0.75mm2): blue, green-yellow, brown (0.34mm2): violet, red, gray, red-blue, green, gray-pink, white-green, white-yellow, white-gray, black, yellow-brown, brown-green, white, yellow, pink, gray-brown Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) CE Lead free Clean room Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1 brown, blue, black brown, blue, black, white brown, blue, black, white, green-yellow

CF9
TPE 5xd

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Chainflex CF9 for outdoor crane systems. E-Chain: Series E4/00

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF9 (for up to 10 cuts of the same type)

4.81

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF9
TPE 5xd

TPE Control cable Chainflex CF9


G for maximum load requirements G TPE outer jacket G oil-resistant G bio-oil-resistant G PVC-free/halogen-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant
Delivery program Part No. CF9.01.03 CF9.03.16.07.03.INI CF9.02.02 CF9.02.03.INI CF9.02.06 CF9.02.07 CF9.02.08 CF9.02.12 CF9.02.18(1) CF9.03.04.INI CF9.03.05.INI CF9.03.06 CF9.03.08 CF9.05.02 CF9.05.03 CF9.05.04 CF9.05.05 CF9.05.07 CF9.05.12 CF9.05.18 CF9.05.25 CF9.05.36 CF9.07.05 CF9.07.07 CF9.07.12 CF9.07.20 CF9.07.25 CF9.10.03 CF9.10.04 CF9.10.05 Number of cores and conductor nominal cross section [mm ]
2

External diameter approx. [mm] 4,0 11,0 4,0 4,5 5,5 6,0 6,5 8,0 9,5 5,0 5,5 6,0 6,5 5,0 5,5 5,5 6,0 7,0 9,5 12,5 13,5 17,5 6,5 7,0 11,0 13,0 14,5 6,0 6,5 7,0 11,5 14,0 17,0 6,5 7,5 8,0 9,5 14,0

Copper index [kg/km] 5 74 5 8 15 17 20 29 44 13 17 20 26 10 15 20 24 34 58 86 120 173 36 50 86 144 180 29 38 48 115 173 241 29 58 72 101 173

Weight [kg/km] 15 159 18 20 35 42 46 70 98 31 37 43 55 31 32 36 46 78 105 165 201 368 58 76 142 231 320 49 56 70 181 267 329 54 86 110 140 265 NEW*

3 x 0,14 4 x 4 x 0,34+3 x 0,75 2 x 0,25 3 x 0,25 6 x 0,25 7 x 0,25 8 x 0,25 12 x 0,25 18 x 0,25 4 x 0,34 5 x 0,34 6 x 0,34 8 x 0,34 2 x 0,5 3 x 0,5 4 x 0,5 5 x 0,5 7 x 0,5 12 x 0,5 18 x 0,5 25 x 0,5 36 x 0,5 5 G 0,75 7 G 0,75 12 G 0,75 20 G 0,75 25 G 0,75 3 G 1,0 4 G 1,0 5 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 2 x 1,5 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5

Class 7.4.4

Image exemplary.

CF9.10.12 CF9.10.18 CF9.10.25 CF9.15.02 CF9.15.04 CF9.15.05 CF9.15.07 CF9.15.12

(1) Delivery time upon inquiry * New in this catalog. G = with green-yellow earth core x = without earth core Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

... no minimum order quantity


4.82
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 7.4.4
Delivery program Part No. CF9.15.18 CF9.15.25 CF9.15.36 CF9.25.04 CF9.25.05 CF9.25.07 CF9.25.12 CF9.25.16 CF9.25.18(7) CF9.25.25 CF9.40.04 CF9.60.04 CF9.60.05 CF9.100.04
(6)

CF9
TPE 5xd

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 17,0 20,0 23,0 9,0 10,0 12,0 17,0 21,0 22,5 24,5 10,0 12,5 14,0 15,5 20,0 26,0

Copper index [kg/km] 360 519 96 120 168 288 384 432 600 154 230 288 384 614 1344 260

Weight [kg/km]

25 G 1,5 36 G 1,5 4 G 2,5 5 G 2,5 7 G 2,5 12 G 2,5 16 G 2,5 18 G 2,5 25 G 2,5 4 G 4,0 4 G 6,0 5 G 6,0 4 G 10,0 4 G 16,0 4 G 35,0

602 840 128 174 301 468 600 827 990 195 310 515 780 1700

CF9.160.04(6) CF9.350.04(6)

(6) Nominal voltage 600/1000 V (7) Nominal voltage 450/750 V Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF9.25.04 in your desired length (0,5 m steps) CF9 Chainflex series .25 Code nominal cross section .04 Number of cores

Please use www.chainflex.eu/en/CF9 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

CF9 for maximum load requirements for both indoor and outdoor applications. E-Chain: System E4/4

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF9 (for up to 10 cuts of the same type)

4.83

Fax +49-2203-96 49-222

400

Tel. +49-2203-96 49-0

Control cable

18 G 1,5

400

CF10
TPE 5xd

TPE Control cable Chainflex CF10


G for maximum load requirements G TPE outer jacket G shielded G oil- and bio-oil-resistant G PVC-free/halogen-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant

Extremely high flexible special conductor

[C]
R

Temperature range moved Temperature range


R

-35 C to +100 C, minimum bending radius 5 x d -40 C to +100 C, minimum bending radius 3 x d 10 m/s, 5 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4

Center element for high tensile stresses

[C]

fixed v max. unsupported/gliding a max.

Braiding in bundles around high-tensile center cord

Travel distance

UV
Gusset-filled, pressure extruded

UV-resistant Nominal voltage Testing voltage Oil Silicon-free

High 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992).

Highly flexible braided copper shield

Pressure extruded, halogen-free TPE blend

Hal

Halogen-free Conductor

Following EN 50267-2-1. Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation Core stranding

Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Class 7.4.4

Core identification

Cores < 0,75 mm2: colour code in accordance with DIN 47100 Cores 0,75 mm2: cores black with white numerals, one

Image exemplary.

core green/yellow.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.84

Price index

Class 7.4.4
Inner jacket Overall shield Outer jacket TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) CE Lead free Clean room Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

CF10
TPE 5xd

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF10 (for up to 10 cuts of the same type)

4.85

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF10
TPE 5xd

TPE Control cable Chainflex CF10


G for maximum load requirements G TPE outer jacket G shielded G oil- and bio-oil-resistant G PVC-free/halogen-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant

Delivery program Part No. CF10.01.12 CF10.01.18 CF10.02.04 CF10.02.08 CF10.02.12 CF10.02.24 CF10.03.05.INI CF10.05.04 CF10.05.05 CF10.05.07 CF10.05.12 CF10.05.18 CF10.05.25 CF10.07.04 CF10.07.05 CF10.07.07 CF10.07.12 CF10.07.20 CF10.07.24 CF10.10.02
Image exemplary.

Number of cores and conductor nominal cross section [mm2] (12 x 0,14)C (18 x 0,14)C (4 x 0,25)C (8 x 0,25)C (12 x 0,25)C (24 x 0,25)C (5 x 0,34)C (4 x 0,5)C (5 x 0,5)C (7 x 0,5)C (12 x 0,5)C (18 x 0,5)C (25 x 0,5)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (20 G 0,75)C (24 G 0,75)C (2 x 1,0)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (24 G 1,0)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C

External diameter approx. [mm] 7,5 10,0 6,5 7,5 9,5 13,0 7,0 7,0 7,5 8,5 11,5 13,5 14,5 7,5 7,5 9,0 12,5 15,0 16,5 7,0 7,5 8,0 8,5 10,0 13,5 16,5 18,0 9,0 9,5 11,5 15,5 20,0

Copper index [kg/km] 36 67 25 40 64 109 32 38 55 54 102 143 167 47 57 85 138 205 239 38 47 59 71 105 169 240 305 96 108 155 235 361

Weight [kg/km] 80 110 52 75 118 212 62 68 91 95 192 270 280 86 95 137 244 346 419 70 84 100 101 166 293 407 506 144 163 225 387 585 NEW* NEW*

CF10.10.03 CF10.10.04 CF10.10.05 CF10.10.07 CF10.10.12 CF10.10.18 CF10.10.24 CF10.15.04

Class 7.4.4

CF10.15.05 CF10.15.07 CF10.15.12 CF10.15.18

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

... no minimum order quantity


4.86
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 7.4.4
Delivery program Part No. CF10.25.04 CF10.25.07 CF10.25.12 CF10.40.04 CF10.40.05 Number of cores and conductor nominal cross section [mm ]
2

CF10
TPE 5xd External diameter approx. [mm] 11,0 13,5 19,0 11,5 13,5 Copper index [kg/km] 126 221 373 200 246 180 331 624 290 353 Weight [kg/km]

(4 G 2,5)C (7 G 2,5)C (12 G 2,5)C (4 G 4,0)C (5 G 4,0)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF10.10.12 in your desired length (0,5 m steps) CF10 Chainflex series .10 Code nominal cross section .12 Number of cores

Please use www.chainflex.eu/en/CF10 for your online order.


Tel. +49-2203-96 49-0 (for up to 10 cuts of the same type)

Delivery time 24h or today*


* Delivery time means time until shipping of goods

Control cable CF10 in storage and retrieval units for high-bay warehouses. E-Chain: System E2 medium

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF10

4.87

Fax +49-2203-96 49-222

Control cable

CF9.UL
TPE 5xd

TPE Control cable Chainflex CF9.UL


G for maximum load requirements G TPE outer jacket G oil- and bio-oil-resistant G flame-retardant G PVC-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant

Highly flexible special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 Torsion 90, with 1 m cable length -40 C to +100 C, minimum bending radius 3 x d -35 C to +100 C, minimum bending radius 5 x d

Center element for high tensile stresses

a max. Travel distance

Braiding in bundles around high-tensile center cord

UV-resistant Nominal voltage Testing voltage Oil

High 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4.

Gusset-filled extruded TPE mixture

Flame-retardant Silicon-free Conductor

According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Core insulation

Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure.

Class 6.4.4

Core stranding

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.88

Price index

Class 6.4.4
Core identification Cores < 0,75 mm2: colour code in accordance with DIN 47100 Cores 0,75 mm2: cores black with white numerals, one core green-yellow. CF9.UL.02.03.INI: CF9.UL.03.04.INI: CF9.UL.03.05.INI: Outer jacket brown, blue, black brown, blue, black, white brown, blue, black, white, green-yellow

CF9.UL
TPE 5xd

Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011)

UL/CSA

< 0,5 mm2: Style 10479 and 21529, 300 V, 90 C 0,5 mm2: Style 10258 and 21530, 600 V, 90 C

CEI CE Lead free Clean room

Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF9UL (for up to 10 cuts of the same type) 4.89

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF9.UL
TPE 5xd

TPE Control cable Chainflex CF9.UL


G for maximum load requirements G TPE outer jacket G oil- and bio-oil-resistant G flame-retardant G PVC-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant
Delivery program Part No. CF9.UL.02.02 CF9.UL.02.03.INI CF9.UL.02.04 CF9.UL.02.06 CF9.UL.02.07 CF9.UL.02.08 CF9.UL.02.12 CF9.UL.03.04.INI CF9.UL.03.05.INI CF9.UL.03.06 CF9.UL.03.08(1) CF9.UL.05.02 CF9.UL.05.03(1) CF9.UL.05.04 CF9.UL.05.05(1) CF9.UL.05.07 CF9.UL.05.12 CF9.UL.05.18 CF9.UL.05.25(1) CF9.UL.05.36 CF9.UL.07.05 CF9.UL.07.07 CF9.UL.07.12 CF9.UL.07.20(1) CF9.UL.07.25 CF9.UL.10.03 CF9.UL.10.04 CF9.UL.10.05(1) CF9.UL.10.12 CF9.UL.10.18 CF9.UL.10.25
(1) (1)

Number of cores and conductor nominal cross section [mm2] 2 x 0,25 3 x 0,25 4 x 0,25 6 x 0,25 7 x 0,25 8 x 0,25 12 x 0,25 4 x 0,34 5 x 0,34 6 x 0,34 8 x 0,34 2 x 0,5 3 x 0,5 4 x 0,5 5 x 0,5 7 x 0,5 12 x 0,5 18 x 0,5 25 x 0,5 36 x 0,5 5 G 0,75 7 G 0,75 12 G 0,75 20 G 0,75 25 G 0,75 3 G 1,0 4 G 1,0 5 G 1,0 12 G 1,0 18 G 1,0 25 G 1,0 4 G 1,5 5 G 1,5 7 G 1,5 12 G 1,5 18 G 1,5 25 G 1,5

External diameter approx. [mm] 5,0 5,5 5,5 6,0 6,5 7,0 8,5 6,0 6,0 6,5 7,5 6,0 6,5 7,0 7,0 8,5 11,0 13,5 14,5 18,5 8,0 9,5 12,5 15,5 16,5 7,5 8,0 8,5 13,5 16,5 18,5 9,0 9,5 11,0 15,5 19,0 22,0

Copper index [kg/km] 5 8 10 15 17 20 29 13 16 20 26 10 15 20 24 34 58 87 120 173 36 51 87 144 180 29 39 48 116 173 240 58 72 101 173 260 360

Weight [kg/km] 28 32 38 50 57 63 95 43 51 58 76 44 52 62 72 97 196 242 305 456 94 128 240 342 412 78 98 112 287 394 520 127 152 198 385 535 685

Class 6.4.4

Image exemplary.

CF9.UL.15.04 CF9.UL.15.05 CF9.UL.15.07 CF9.UL.15.12 CF9.UL.15.18 CF9.UL.15.25

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity


4.90 eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.4.4
Delivery program Part No. CF9.UL.25.04 CF9.UL.25.05 CF9.UL.25.07 CF9.UL.25.12 CF9.UL.25.16(1) CF9.UL.25.18 CF9.UL.25.25 CF9.UL.40.04 CF9.UL.60.04
(1)

CF9.UL
TPE 5xd

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 10,5 11,0 13,5 19,0 21,5 23,5 26,5 12,0 13,5

Copper index [kg/km] 120 168 288 384 432 600 154 231 96

Weight [kg/km]

5 G 2,5 7 G 2,5 12 G 2,5 16 G 2,5 18 G 2,5 25 G 2,5 4 G 4,0 4 G 6,0

220 288 613 805 852 1163 278 382

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Please use www.chainflex.eu/en/CF9UL for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

igus Chainflex cables in a rafting channel application.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF9UL (for up to 10 cuts of the same type) 4.91

Tel. +49-2203-96 49-0

Order example: CF9.UL.02.12 in your desired length (0,5 m steps) CF9.UL Chainflex series .02 Code nominal cross section .12 Number of cores

Fax +49-2203-96 49-222

Control cable

4 G 2,5

189

CF10.UL
TPE 5xd

TPE Control cable Chainflex CF10.UL


G for maximum load requirements G TPE outer jacket G shielded G oil- and bio-oil-resistant G flame-retardant G PVC-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant
Temperature range moved -35 C to +100 C, minimum bending radius 5 x d -40 C to +100 C, minimum bending radius 3 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 UV-resistant High 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Flame-retardant Silicon-free Conductor According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Core insulation Core stranding Mechanically high-quality TPE mixture. Number of cores < 12: cores stranded in a layer with short pitch length. Number of cores 12: cores combined in bundles and stranded together around a centre for high tensile stresses with adapted, short pitch lengths and pitch directions, especially low-torsion structure. Core identification Cores < 0,75 mm2: colour code in accordance with DIN 47100 Cores 0,75 mm2: cores black with white numerals, one core green-yellow.
Image exemplary.

Highly flexible special conductor

Center element for high tensile stresses

Temperature range fixed v max. unsupported/gliding a max.

Braiding in bundles around high-tensile center cord

Travel distance

Gusset-filled extruded

Nominal voltage Testing voltage Oil

Highly flexible braided copper shield

Pressure extruded TPE blend

Class 6.4.4

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.92

Price index

Class 6.4.4
Inner jacket Overall shield Outer jacket TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) UL/CSA < 0,5 mm2: Style 10479 and 21529, 300 V, 90 C 0,5 mm2: Style 10258 and 21530, 600 V, 90 C CEI CE Lead free Clean room Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CF10.UL
TPE 5xd

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF10UL (for up to 10 cuts of the same type) 4.93

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF10.UL
TPE 5xd

TPE Control cable Chainflex CF10.UL


G for maximum load requirements G TPE outer jacket G shielded G oil- and bio-oil-resistant G flame-retardant G PVC-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant
Delivery program Part No. CF10.UL.02.04 CF10.UL.02.08 CF10.UL.02.12 CF10.UL.02.24 CF10.UL.05.04 CF10.UL.05.05(1) CF10.UL.05.12 CF10.UL.05.18(1) CF10.UL.05.25 CF10.UL.07.03 CF10.UL.07.04 CF10.UL.07.05 CF10.UL.07.07 CF10.UL.07.12 CF10.UL.07.20 CF10.UL.10.02 CF10.UL.10.04 CF10.UL.10.05(1)
(1)

Number of cores and conductor nominal cross section [mm2] (4 x 0,25)C (8 x 0,25)C (12 x 0,25)C (24 x 0,25)C (4 x 0,5)C (5 x 0,5)C (12 x 0,5)C (18 x 0,5)C (25 x 0,5)C (3 G 0,75)C (4 G 0,75)C (5 G 0,75)C (7 G 0,75)C (12 G 0,75)C (20 G 0,75)C (24 G 0,75)C (2 x 1,0)C (3 G 1,0)C (4 G 1,0)C (5 G 1,0)C (7 G 1,0)C (12 G 1,0)C (18 G 1,0)C (24 G 1,0)C (4 G 1,5)C (5 G 1,5)C (7 G 1,5)C (12 G 1,5)C (18 G 1,5)C (4 G 2,5)C (7 G 2,5)C (12 G 2,5)C (4 G 4,0)C

External diameter approx. [mm] 7,0 8,5 10,0 13,0 8,5 8,5 13,0 15,0 16,0 8,5 9,0 9,5 11,0 14,5 17,0 19,0 8,5 9,0 9,5 10,5 12,0 14,5 19,0 21,5 10,5 11,0 13,0 17,5 21,5 12,0 15,0 21,5 13,5

Copper index [kg/km] 25 37 63 109 37 43 106 146 185 40 49 68 90 143 213 276 38 48 71 83 111 171 274 346 192 215 149 243 375 140 227 404 206

Weight [kg/km] 71 101 153 242 101 111 258 332 411 104 123 150 194 336 456 578 104 120 155 174 230 370 545 709 94 112 279 508 724 268 404 804 369

CF10.UL.07.24(1)
(1)

CF10.UL.10.03(1)

Image exemplary.

CF10.UL.10.07 CF10.UL.10.12

(1)

CF10.UL.10.18(1) CF10.UL.10.24(1) CF10.UL.15.04 CF10.UL.15.05 CF10.UL.15.07 CF10.UL.15.12

Class 6.4.4

CF10.UL.15.18 CF10.UL.25.04 CF10.UL.25.07 CF10.UL.25.12 CF10.UL.40.04

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity


4.94 eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.4.4
Order example: CF10.UL.10.02 in your desired length (0,5 m steps) CF10.UL Chainflex series .10 Code nominal cross section .02 Number of cores

CF10.UL
TPE 5xd

Please use www.chainflex.eu/en/CF10UL for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Braiding in bundles

Center element for high tensile stresses

Gusset-filled extruded inner jacket

Total shield with optimized braiding angle

Pressure extruded outer jacket

The special cable structure of Chainflex CF10.UL guarantees quality also in the igus harnessing.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF10UL (for up to 10 cuts of the same type) 4.95

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

CF98
TPE 4xd

TPE Control cable Chainflex CF98


G for maximum load requirements and especially small radii up to 4 x d G TPE outer jacket G oil- and bio-oil-resistant G PVC-free/halogen-free G low-temperature-flexible G hydrolysis-resistant and microbe-resistant
[C]
R

Temperature range moved Temperature range


R

-35 C to +90 C, minimum bending radius 4 x d -40 C to +90 C, minimum bending radius 3 x d 10 m/s, 6 m/s 100 m/s2 Short, very fast applications with small radii and tight design space, Class 4 90, with 1 m cable length High 300/300 V 1500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Following EN 50267-2-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Conductor consisting of a highly flexible special alloy. Mechanically high-quality TPE mixture. Cores stranded in one layer with especially short pitch length. Colour code in accordance with DIN 47100. CF9.02.03.INI: brown, blue, black CF9.03.04.INI: brown, blue, black, white

[C]

fixed v max. unsupported/gliding a max. Travel distance Torsion

Extremely highly flexible special alloy

UV UV-resistant Nominal voltage Testing voltage Oil


Braiding in layers with extremely short pitch

Hal

Halogen-free Silicon-free Conductor Core insulation Core stranding Core identification

Gusset-filled extruded, halogen-free TPE mixture

Class 7.4.4

Outer jacket

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011)

CE Lead free
Image exemplary.

Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Clean room

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.96

Price index

Class 7.4.4
Typical application area
n for maximum load requirements at 4 x d n indoor and outdoor applications, UV-resistant n especially for short, very fast applications with small radii and tight design space n automatic insertion machines, automatic doors, clean room, very quick handling Delivery program Part No. CF98.01.02 CF98.01.03(1) CF98.01.04 CF98.01.07(1) CF98.01.08 CF98.02.03.INI CF98.02.04 CF98.02.07 CF98.02.08 CF98.03.03 CF98.03.07 CF98.03.08(1) CF98.05.04
(1)

CF98
TPE 4xd

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 4,0 4,5 5,0 6,0 6,5 5,0 5,5 6,5 7,0 5,0 5,5 7,0 7,5 6,0

Copper index [kg/km] 4,0 6,3 8,5 14,0 16,0 12,0 16,0 26,0 30,0 14,4 19,4 32,0 38,0 31,0

Weight [kg/km] 11 14 16 21 24 25 30 53 60 28 35 55 63 40

2 x 0,14 3 x 0,14 4 x 0,14 7 x 0,14 8 x 0,14 3 x 0,25 4 x 0,25 7 x 0,25 8 x 0,25 3 x 0,34 4 x 0,34 7 x 0,34 8 x 0,34 4 x 0,5

CF98.03.04.INI

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF98.02.04 in your desired length (0,5 m steps) CF98 Chainflex series .02 Code nominal cross section .04 Number of cores

Please use www.chainflex.eu/en/CF98 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Test data Page 4.32

Chainflex CF98 for maximum load requirements and especially small radii at automatic doors.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF98 (for up to 10 cuts of the same type)

4.97

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

n almost unlimited resistance to oil, also with bio-oils

CF99
TPE 4xd

TPE Control cable Chainflex CF99


G for maximum load requirements and especially small radii up to 4 x d G TPE outer jacket G shielded G oil- and bio-oil-resistant G PVC-free/halogen-free G low-temperature-flexible
[C]
R

Extremely highly flexible special alloy

[C]
R

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance

-35 C to +90 C, minimum bending radius 4 x d -40 C to +90 C, minimum bending radius 3 x d 10 m/s, 6 m/s 100 m/s2 Short, very fast applications with small radii and tight design space, Class 4 High 300/300 V 1500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Following EN 50267-2-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Conductor consisting of a highly flexible special alloy. Mechanically high-quality TPE mixture. Cores stranded in one layer with especially short pitch length. Colour code in accordance with DIN 47100. TPE mixture adapted to suit the requirements in Energy Chains. Highly flexible alloyed special shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) Following 2006/95/EG

Braiding in layers with extremely short pitch

UV

UV-resistant Nominal voltage Testing voltage

Gusset-filled extruded

Oil

Extremely highly flexible special shield made of alloyed wires

Hal

Halogen-free Silicon-free

Pressure extruded, halogen-free TPE blend

Conductor Core insulation Core stranding Core identification Inner jacket

Class 7.4.4

Overall shield Outer jacket

Image exemplary.

CE

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.98

Price index

Class 7.4.4
Lead free Following EC (RoHS) 2002/95/EC. Clean room According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

CF99
TPE 4xd

Typical application area


n for maximum load requirements at 4 x d n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for short, very fast applications with small radii and tight design space n automatic insertion machines, automatic doors, clean room, very quick handling Delivery program Part No. CF99.01.02 CF99.01.03(1) CF99.01.04 CF99.01.07(1) CF99.01.08 CF99.02.03(1) CF99.02.04 CF99.02.07 CF99.02.08(1) CF99.03.03(1) CF99.03.04(1) CF99.03.08
(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 5,5 6,0 6,0 7,5 8,0 6,5 6,5 8,0 8,5 6,5 7,0 9,0

Copper index [kg/km] 13,5 16,5 21,0 31,5 36,0 25,0 30,0 48,0 54,0 27,0 35,0 64,0

Weight [kg/km] 33,0 37,0 43,0 62,0 69,0 48,0 56,0 85,0 93,0 51,0 62,0 105,0

(2 x 0,14)C (3 x 0,14)C (4 x 0,14)C (7 x 0,14)C (8 x 0,14)C (3 x 0,25)C (4 x 0,25)C (7 x 0,25)C (8 x 0,25)C (3 x 0,34)C (4 x 0,34)C (8 x 0,34)C

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF99.01.02 in your desired length (0,5 m steps) CF99 Chainflex series .01 Code nominal cross section .02 Number of cores

Please use www.chainflex.eu/en/CF99 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Automatisierte Stapelanlage fr Phosphorbildschirme: gerader Installationsraum, kleiner Biegeradius, 300.000 Doppelhbe pro Monat.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF99 (for up to 10 cuts of the same type)

4.99

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Control cable

us cables Encoder cables Koax cables

ata cables

Minimum bending radius, moved [factor x d]

Torsion resistant

Chainflex types
Approvals and standards Temperature moved from/to [C] Oil-resistant Chainflex cable Jacket Shield

a max. [m/s2]

v max. [m/s] unsupported

v max. [m/s] gliding

Data cables CF240 CF211 CF112 CF113 CF11 CF12 Bus cables
NEW** PVC PVC PUR PUR TPE TPE       10-12 10 10 10 10 10 -5/ +70 -5/ +70 -35/ +80 -35/ +80 -35/ +100 -35/ +100       3 5 10 10 10 10 2 3 5 5 6 6 20 50 80 80 100 100 4.102 4.104 4.106 4.108 4.110 4.112

(with selection chart for Chainflex bus cables) 4.114


PVC  12,5 -5/ +70  2 30 4.118

CFBUS.PVC*
NEW**

CFBUS.PUR* PUR CF BUS* CF11.LC* CF11.LC.D* CF14 CAT5*


TPE TPE TPE TPE

12,5

-35/ +70 -35/ +70 -35/ +70 -35/ +70 -35/ +70

    

2 10 10 10 10 6 6 6 6

30 100 100 100 100

4.120 4.122 4.126 4.128 4.130

 10-12,5    10 10 12,5

Measuring system cables CF211 CF113.D CF111.D CF11.D Koax cables CF KOAX 1
TPE 10 -35/ +100  10 5 100 4.152 PVC PUR TPE TPE     10 10 12 10 -5/ +70 -20/ +80 -35/ +100 -35/ +100     5 5 2 10 6 3 3 50 50 30 100 4.132 4.136 4.142 4.146

* Selection chart for bus cables: Field bus page 4.114 High-speed bus page 4.116
** New in this catalog.

Page

4.101

CF240
PVC 10-12 x d

PVC Data cable Chainflex CF240


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Temperature range moved

-5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles Minimum bending radius 10 x d with < 10 m travel, minimum bending radius 12 x d with 10 m travel -20 C to +70 C, minimum bending radius 5 x d 3 m/s, 2 m/s 20 m/s2 Freely suspended and gliding travel distances up to 50 m, Class 2 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PVC mixture (following DIN VDE 0207 Part 4). The individual cores are stranded in layers with short pitch lengths. Colour code in accordance with DIN 47100. Foil taping over the external layer. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) Style 10467 and 2464, 300 V, 80 C Following CEI 20-35 Following 2006/95/EG

Fine-wire special conductor

Temperature range fixed v max. unsupported/gliding a max. Travel distance

Braiding in layers with extremely short pitch

Nominal voltage Testing voltage Oil

Flame-retardant Silicon-free
Highly flexible braided copper shield

Conductor Core insulation

Pressure extruded

Core stranding Core identification Intermediate sheath Overall shield

Class 4.2.2

Outer jacket

UL/CSA CEI
Image exemplary.

CE

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.102

Price index

Class 4.2.2
Lead free Clean room Following EC (RoHS) 2002/95/EC According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1

CF240
PVC 10-12 x d

Typical application area


n for high load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 50 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes

Delivery program Part No. CF240.01.03 CF240.01.04 CF240.01.05 CF240.01.07 CF240.01.14 CF240.01.18 CF240.01.24 CF240.02.03 CF240.02.04 CF240.02.05 CF240.02.07 CF240.02.08 CF240.02.14 CF240.02.18 CF240.02.24 CF240.03.03 CF240.03.04 CF240.03.05 CF240.03.07 CF240.03.10 CF240.03.14 CF240.03.18 CF240.03.24

Number of cores and conductor nominal cross section [mm2] (3 x 0,14)C (4 x 0,14)C (5 x 0,14)C (7 x 0,14)C (14 x 0,14)C (18 x 0,14)C (24 x 0,14)C (3 x 0,25)C (4 x 0,25)C (5 x 0,25)C (7 x 0,25)C (8 x 0,25)C (14 x 0,25)C (18 x 0,25)C (24 x 0,25)C (3 x 0,34)C (4 x 0,34)C (5 x 0,34)C (7 x 0,34)C (10 x 0,34)C (14 x 0,34)C (18 x 0,34)C (24 x 0,34)C

External diameter approx. [mm] 4,5 5,0 5,5 6,0 7,0 8,0 9,5 5,5 5,5 6,0 7,0 7,5 8,0 9,0 11,0 5,5 6,0 6,5 7,0 8,5 8,5 10,0 12,0

Copper index [kg/km] 16 18 20 25 42 48 60 21 24 27 35 40 57 71 92 24 28 32 43 55 71 87 115

Weight [kg/km] 35 38 42 51 76 90 113 40 48 52 66 74 100 122 174 45 51 58 75 110 116 140 203

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF240.02.03 in your desired length (0,5 m steps) CF240 Chainflex series .02 Code nominal cross section .03 Number of cores

Please use www.chainflex.eu/en/CF240 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF240 (for up to 10 cuts of the same type)

4.103

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Data cable

CF211
PVC 10 x d

PVC Data cable Chainflex CF211


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Nominal voltage Testing voltage -5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles. Minimum bending radius 10 x d -20 C to +70 C, minimum bending radius 5 x d 5 m/s, 3 m/s 50 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PVC mixture (following DIN VDE 0207 Part 4). 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100. Foil taping over the external layer. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0281 Part 13). Colour: Silver gray (similar to RAL 7001) < 0,5 mm2: Style 10467 and 2464, 300 V, 80C 0,5 mm2: Style 1729 and 2464, 300 V, 80 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1

Center element for high tensile stresses

Fine-wire special conductor

2 cores each stranded with short pitch

Oil Flame-retardant Silicon-free Conductor

Highly flexible braided copper shield

Core insulation Core stranding Core identification

Pressure extruded

Intermediate sheath Overall shield Outer jacket

UL/CSA

Class 5.3.2

CEI CE Lead free Clean room


Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.104

Price index

Class 5.3.2
Typical application area
n for high load requirements n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes n light oil influence

CF211
PVC 10 x d

Delivery program Part No. CF211.02.01.02 CF211.02.02.02(2) CF211.02.03.02 CF211.02.04.02 CF211.02.05.02 CF211.02.06.02 CF211.02.08.02 CF211.02.10.02 CF211.02.14.02 CF211.03.03.02 CF211.03.08.02 CF211.03.10.02(1) CF211.05.01.02 CF211.05.02.02(2) CF211.05.03.02 CF211.05.04.02 CF211.05.05.02 CF211.05.06.02 CF211.05.08.02 CF211.05.10.02 CF211.05.14.02

Number of cores and conductor nominal cross section [mm2] (1 x (2 x 0,25))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (8 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (3 x (2 x 0,34))C (8 x (2 x 0,34))C (10 x (2 x 0,34))C (1 x (2 x 0,5))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (10 x (2 x 0,5))C (14 x (2 x 0,5))C

External diameter approx. [mm] 5,0 5,5 7,0 8,0 8,5 9,5 11,5 13,0 13,5 8,0 12,0 12,0 5,5 8,5 9,0 9,5 11,0 12,5 14,5 16,0 17,0

Copper index [kg/km] 16 28 37 44 51 58 75 93 109 37 98 118 23 44 57 68 80 99 124 175 187

Weight [kg/km] 35 60 73 85 97 110 160 195 205 79 202 254 50 80 100 120 145 185 230 320 335

(1) Delivery time upon inquiry The Chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF211.02.04.02 in your desired length (0,5 m steps) CF211 Chainflex series .02 Code nominal cross section .04 Number of pairs .02 Identification pairs

Please use www.chainflex.eu/en/CF211 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Delivery program Measuring system cable Page 4.132, CF211 (PVC) Page 4.142, CF111.D (TPE) Page 4.146, CF11.D (TPE)

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF211 (for up to 10 cuts of the same type)

4.105

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Data cable

NEW in this catalog.


CF112
PUR 10 x d

PUR Data cable Chainflex CF112


G for high load requirements G PUR outer jacket G double-shielded, twisted-pair G oil-resistant and coolant-resistant G notch-resistant G PVC-free/halogen-free G flame-retardant G hydrolysis-resistant and microbe-resistant

Especially bendingresistant fine-wire stranded conductor

Highly flexible braided copper shield

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Nominal voltage Testing voltage

-35 C to +80 C, minimum bending radius 10 x d -40 C to +80 C, minimum bending radius 5 x d

Center element for high tensile stresses

10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100 Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. PUR mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10).

2 cores each stranded with short pitch

Gusset-filled extruded

Oil Flame-retardant

Highly flexible braided copper shield

Silicon-free Conductor Core insulation Core stranding Core identification Element shield

Pressure extruded, halogen-free PUR blend

Class 6.3.3

Intermediate jacket Overall shield Outer jacket

Image exemplary.

Colour: gray (similar to RAL 7016)

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.106

Price index

Class 6.3.3
UL/CSA CEI CE Lead free Style 10493 and 20233, 300 V, 80C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

CF112
PUR 10 x d

Typical application area


n for high load requirements n almost unlimited resistance to oil n indoor and outdoor applications with average sun radiation n especially for freely suspended and gliding travel distances up to 100 m n Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No. CF112.02.02.02 CF112.02.03.02 CF112.02.04.02 CF112.02.05.02(1) CF112.02.06.02(1) CF112.05.02.02 CF112.05.04.02 CF112.05.05.02(1) CF112.05.06.02
(1) (1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 9,5 10,0 11,0 11,5 12,0 11,5 12,0 12,5 13,5 14,5

Copper index [kg/km] 54 68 78 95 107 72 95 113 137 155

Weight [kg/km] 125 144 159 184 210 168 192 221 263 307

(2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (6 x (2 x 0,25)C)C (2 x (2 x 0,5)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C

CF112.05.03.02(1)

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF112.02.04.02 in your desired length (0,5 m steps) CF112 Chainflex series .02 Code nominal cross section .04 Number of pairs .02 Identification pairs

Please use www.chainflex.eu/en/CF112 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF112 (for up to 10 cuts of the same type) 4.107

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Data cable

NEW in this catalog.


CF113
PUR 10 x d

PUR Data cable Chainflex CF113


G for high load requirements G PUR outer jacket G twisted-pair G oil-resistant and coolant-resistant G notch-resistant G PVC-free/halogen-free G flame-retardant G hydrolysis-resistant and microbe-resistant

Especially bendingresistant fine-wire stranded conductor

Center element for high tensile stresses

Temperature range moved Temperature range fixed


2 cores each stranded with short pitch

-35 C to +80 C, minimum bending radius 10 x d -40 C to +80 C, minimum bending radius 5 x d

v max. unsupported/gliding a max. Travel distance Nominal voltage 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). Halogen-free Following EN 50267-2-1. Very finely stranded special cores of particularly high-flex design made of bare copper wires. Core insulation Core stranding Core identification Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100 PUR mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: gray (similar to RAL 7016)
Image exemplary.

Gusset-filled extruded

Testing voltage . Oil Flame-retardant Silicon-free

Highly flexible braided copper shield

Pressure extruded, halogen-free PUR blend

Conductor

Class 6.3.3

Intermediate jacket Overall shield

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.108

Price index

Class 6.3.3
UL/CSA CEI CE Lead free Style 10493 and 20233, 300 V, 80C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

CF113
PUR 10 x d

Typical application area


n for high load requirements n almost unlimited resistance to oil n indoor and outdoor applications with average sun radiation n especially for freely suspended and gliding travel distances up to 100 m n Machining units/machine tools, storage and retrieval units for high-bay warehouses, packaging industry, quick handling, refrigerating sector

Delivery program Part No. CF113.02.02.02(2) CF113.02.03.02 CF113.02.04.02 CF113.02.05.02 CF113.02.06.02 CF113.05.02.02 CF113.05.04.02 CF113.05.05.02(1) CF113.05.06.02
(2)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 8,0 8,5 9,0 9,5 10,0 10,0 10,5 11,0 11,5 12,5

Copper index [kg/km] 31 40 45 56 62 50 62 70 84 95

Weight [kg/km] 86 96 107 125 137 127 142 162 185 207

(2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (2 x (2 x 0,5))C (3 x (2 x 0,5))C (4 x (2 x 0,5))C (5 x (2 x 0,5))C (6 x (2 x 0,5))C

CF113.05.03.02(1)

(1) Delivery time upon inquiry The Chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF113.02.06.02 in your desired length (0,5 m steps) CF113 Chainflex series .02 Code nominal cross section .06 Number of pairs .02 Identification pairs

Please use www.chainflex.eu/en/CF113 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF113 (for up to 10 cuts of the same type) 4.109

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Data cable

CF11
TPE 10 x d

TPE Data cable Chainflex CF11


G for maximum load requirements G TPE outer jacket G shielded G oil-resistant G bio-oil-resistant G PVC-free/halogen-free G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max.

Especially bendingresistant fine-wire stranded conductor

-35 C to +100 C, minimum bending radius 10 x d -40 C to +100 C, minimum bending radius 5 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 High 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 1.0 mm2: colour code in accordance with DIN 47100 Cores 1.0 mm2: cores black with white numerals TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

2 cores each stranded in especially short pitch

Travel distance

UV-resistant Nominal voltage Testing voltage


Gusset-filled extruded

Oil Silicon-free
Highly flexible braided copper shield

Halogen-free Conductor

Pressure extruded, halogen-free TPE blend

Core insulation Core stranding Core identification Inner jacket Overall shield

Class 6.4.4

Outer jacket

CE Lead free
Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.110

Price index

Class 6.4.4
Clean room According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

CF11
TPE 10 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications Delivery program Bus cable Part No. CF11.01.04.02 CF11.01.18.02 CF11.02.02.02(2) CF11.02.03.02 CF11.02.04.02 CF11.02.05.02 CF11.02.06.02 CF11.02.09.02 CF11.02.10.02 CF11.02.14.02 CF11.03.08.02 CF11.05.04.02 CF11.05.06.02 CF11.05.08.02 CF11.07.03.02 CF11.10.04.02 CF11.15.06.02 CF11.25.03.02 Number of cores and conductor nominal cross section [mm ]
2

External diameter approx. [mm] 7,0 14,0 6,5 8,0 9,0 9,0 10,0 12,5 13,0 13,5 12,5 10,0 11,5 14,0 11,0 12,0 17,0 16,5

Copper index [kg/km] 28 86 25 34 44 55 66 92 99 120 90 91 95 131 77 121 242 210

Weight [kg/km] 64 164 52 60 80 100 127 198 200 238 154 108 190 250 131 180 419 410 NEW* NEW*

(4 x (2 x 0,14))C (18 x (2 x 0,14))C (2 x (2 x 0,25))C (3 x (2 x 0,25))C (4 x (2 x 0,25))C (5 x (2 x 0,25))C (6 x (2 x 0,25))C (9 x (2 x 0,25))C (10 x (2 x 0,25))C (14 x (2 x 0,25))C (8 x (2 x 0,34))C (4 x (2 x 0,5))C (6 x (2 x 0,5))C (8 x (2 x 0,5))C (3 x (2 x 0,75))C (4 x (2 x 1,0))C (6 x (2 x 1,5))C (3 x (2 x 2,5))C

The Chainflex types marked with (2) are cables designed as a star-quad. * New in this catalog. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF11.02.03.02 in your desired length (0,5 m steps) CF11 Chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs

Please use www.chainflex.eu/en/CF111 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Delivery program Measuring system cable Page 4.132, CF211 (PVC) Page 4.142, CF111.D (TPE) Page 4.146, CF11.D (TPE)

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF11 (for up to 10 cuts of the same type)

4.111

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Data cable

CF12
TPE 10 x d

TPE Data cable Chainflex CF12


G for maximum load requirements G TPE outer jacket G double-shielded G oil-resistant G bio-oil-resistant G PVC-free/halogen-free G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max.

Especially bendingresistant fine-wire stranded conductor

Pressure extrudet element jacket

-35 C to +100 C, minimum bending radius 10 x d -40 C to +100 C, minimum bending radius 5 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m, Class 4 High 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Cores < 0,5 mm2: colour code in accordance with DIN 47100 Cores 0,5 mm2: cores black with white numerals Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in Energy Chains over pair shield. TPE mixture adapted to suit the requirements in Energy Chains. Highly flexible shield consisting of galvanized steel wire braid. Coverage approx. 70% linear, approx. 90% optical.

Highly flexible braided copper shield

Center element for high tensile stresses

Travel distance

2 cores each stranded in especially short pitch

UV-resistant Nominal voltage Testing voltage

Gusset-filled, pressure extruded

Oil Silicon-free

Highly flexible steel wire braid

Halogen-free Conductor

Pressure extruded, halogen-free TPE blend

Core insulation Core stranding Core identification

Class 6.4.4

Element shield Element jacket

Inner jacket Overall shield


Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.112

Price index

Class 6.4.4
Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) CE Lead free Clean room Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

CF12
TPE 10 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications, for especially high EMC safety

Delivery program Part No. CF12.02.02.02 CF12.02.03.02 CF12.02.04.02 CF12.02.05.02 CF12.05.03.02 CF12.05.04.02 CF12.05.05.02 CF12.05.06.02 CF12.05.08.02 CF12.05.10.02 CF12.05.14.02 CF12.10.06.02
(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 11,0 11,5 11,5 13,0 13,0 14,0 15,5 17,0 20,0 23,0 23,0 20,0

Copper index [kg/km] 27 40 61 93 66 88 110 132 177 221 309 198

Weight [kg/km] 152 172 179 220 210 255 297 360 477 548 723 542

(2 x (2 x 0,25)C)C (3 x (2 x 0,25)C)C (4 x (2 x 0,25)C)C (5 x (2 x 0,25)C)C (3 x (2 x 0,5)C)C (4 x (2 x 0,5)C)C (5 x (2 x 0,5)C)C (6 x (2 x 0,5)C)C (8 x (2 x 0,5)C)C (10 x (2 x 0,5)C)C (14 x (2 x 0,5)C)C (6 x (2 x 1,0)C)C

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF12.02.03.02 in your desired length (0,5 m steps) CF12 Chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs

Please use www.chainflex.eu/en/CF12 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Test data Page 4.35

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF12 (for up to 10 cuts of the same type)

4.113

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Data cable

Selection Chainflex bus cable

Selection chart field bus for Chainflex bus cables


Chainflex cable CF BUS
CFBUS.001 CFBUS.002 CFBUS.003 CFBUS.010 CFBUS.011 CFBUS.020 CFBUS.021 CFBUS.022 CFBUS.030 CFBUS.031 CFBUS.035           Profibus Interbus CAN Bus DeviceNet

CF11.LC
CF11.02.02.02.PBA.LC CF11.05.01.02.LC CF11.05.02.02.LC CF11.02.03.02.IB-S CF11.02.03.02.10.03.IB-S     

CF11.LC.D
CF11.02.02.02.LC.D CF11.05.01.02.LC.D CF11.02.01.02.PBA.LC.D CF11.02.02.07.03.PBA.LC.D CF11.02.02.15.04.PBA.LC.D     

CF BUS.PVC
CFBUS.PVC.001 CFBUS.PVC.021 CFBUS.PVC.022   

CF BUS.PUR
CFBUS.PUR.001 CFBUS.PUR.021 CFBUS.PUR.022   

CF ROBOT
Robot8.001 Robot8.022  

4.114

Selection chart high-speed bus

page 4.116

Selection Chainflex bus cable

CC-Link

Characteristic wave impedance [ ]

150 150 150 100 100 120 120 120 120 120  110

          

          

          

          

          

          

4.122 4.122 4.122 4.122 4.122 4.122 4.122

4.122 4.122 4.122

150 120 120 100 100

    

    

    

4.126 4.126 4.126 4.126 4.126

120 120 150 150 150

    

    

    

    

4.128 4.128 4.128 4.128 4.128

150 120 120

  

  

  

  

  

4.118 4.118 4.118

150 120 120

  

  

  

  

  

  

  

4.120 4.120 4.120

150 120

 

 

 

4.222 4.222

Tel. +49-2203-96 49-0

4.122

4.115

Fax +49-2203-96 49-222

Bus cable

Flameretardant

Halogen-free Page

Selection Chainflex bus cable

Selection chart high-speed bus for Chainflex bus cables


Chainflex cable CF BUS.PVC
CFBUS.PVC.045   Ethernet/ CAT5 Ethernet/ CAT6 GigE Profinet FireWire

CF BUS.PUR
CFBUS.PUR.045  

CF BUS
CFBUS.040 CFBUS.041 CFBUS.042 CFBUS.044 CFBUS.045 CFBUS.050 CFBUS.055 CFBUS.060 CFBUS.065 CFBUS.066 CFBUS.070          

CF14 CAT5
CF14.02.02.02.CAT5 CF14.02.04.02.CAT5 CF14.02.05.02.CAT5   

CF ROBOT
Robot8.045  

Selection chart field bus

page 4.114

4.116

Selection Chainflex bus cable

USB

DVI

Characteristic wave impedance [ ]

100

4.118

100

4.120

100 100 100 100 100 100 100 100    90 90 100

          

          

          

          

          

          

4.122 4.122

4.122 4.122 4.122 4.122 4.122 4.122 4.122 4.122

100 100 100

  

  

  

  

4.130 4.130 4.130

100

4.222

Tel. +49-2203-96 49-0

4.122

4.117

Fax +49-2203-96 49-222

Bus cable

Flameretardant

Halogen-free Page

NEW in this catalog.


CFBUS.PVC PVC 12,5 x d

PVC Bus cable Chainflex CFBUS.PVC


G for medium load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Temperature range
Especially bendingresistant fine-wire stranded conductor

-5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles. Minimum bending radius 12,5 x d -20 C to +70 C, minimum bending radius 7,5 x d

moved Temperature range fixed v max. unsupported

2 m/s 30 m/s2 Freely suspended travel distances, Class 1. Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification. According to bus specification. According to bus specification Schedule delivery program Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0281 Part 13). Colour: Red lilac (similar to RAL 4001)

Cores each stranded in especially short pitch

a max. Travel distance UV-resistant Nominal voltage Testing voltage Oil

Bending-resistant braided copper shield

Flame-retardant Silicon-free Conductor

Pressure extruded, flame-retard PVC blend

Core insulation Core stranding Core identification Overall shield

Class 4.1.2

Outer jacket

UL/CSA CEI
Image exemplary.

Style 1598 and 2571, 30 V, 80 C Following CEI 20-35

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.118

Price index

Class 4.1.2
CE Lead free Following 2006/95/EG Following EC (RoHS) 2002/95/EC

CFBUS.PVC PVC 12,5 x d

Typical application area


n for medium load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended travel distances n Bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, handling, indoor cranes

Delivery program Part No. Profibus CFBUS.PVC.001 CAN-Bus CFBUS.PVC.021 CFBUS.PVC.022 CFBUS.PVC.045
(2)

Number of cores and conductor nominal cross section [mm2] (2x0,25)C (2x0,5)C (2x(2x0,5))C (4x(2x0,15))C

External diameter in mm approx. 8,0 8,5 8,5 7,0

Copper index [kg/km] 22 27 38 34

Weight [kg/km]

71 81 94 62

Ethernet/CAT5/GigE
The Chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Part No. Profibus CFBUS.PVC.001 CAN-Bus CFBUS.PVC.021 CFBUS.PVC.022 Ethernet/CAT5/GigE CFBUS.PVC.045

Characteristic in approx. 150 120 120 100

Number of cores Colour code nominal cross section [mm2] (2x0,25)C (2x0,5)C (2x(2x0,5))C (4x(2x0,15))C red, green white, brown white, green, brown, yellow (star-quad stranding) white-blue/blue, white-orange/orange, white-green/green, white-brown/brown

wave impedance and conductor

Order example: CFBUS.PVC.001 in your desired length (0,5 m steps) CFBUS.PVC Chainflex series .001 Code Bus type

Please use www.chainflex.eu/en/CFBUSPVC for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods * Die Lieferzeit bedeutet die Zeit bis zum Versand der Ware

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFBUSPVC (for up to 10 cuts of the same type) 4.119

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Bus cable

NEW in this catalog.


CFBUS.PUR PUR 12,5 x d

PUR Bus cable Chainflex CFBUS.PUR


G for medium load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G PVC-free/halogen-free G flame-retardant G hydrolysis-resistant and microbe-resistant
Temperature range

Especially bendingresistant fine-wire stranded conductor

moved Temperature range fixed v max. unsupported/gliding a max.

-35 C to +70 C, minimum bending radius 10-12.5 x d -40 C to +70 C, minimum bending radius 5 x d 10 m/s, 6 m/s 30 m/s2 Freely suspended travel distances, Class 1. Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1 Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification. According to bus specification. According to bus specification Schedule delivery program Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Red lilac (similar to RAL 4001)

Cores each stranded in especially short pitch

Travel distance UV-resistant Nominal voltage Testing voltage Oil Flame-retardant Silicon-free Halogen-free

Bending-resistant braided copper shield

Pressure extruded, flame-retard PUR blend

Conductor Core insulation Core stranding Core identification

Class 4.1.3

Overall shield Outer jacket

UL/CSA
Image exemplary.

Style 1598 and 20236, 30 V, 80 C

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.120

Price index

Class 4.1.3
CEI CE DESINA Lead free Following CEI 20-35 Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC

CFBUS.PUR PUR 12,5 x d

Typical application area


n for medium load requirements n almost unlimited resistance to oil n indoor and outdoor applications without direct sun radiation n especially for freely suspended travel distances n Bus connection cable for machining units/machine tools, low-temperature applications Delivery program Part No. Profibus CFBUS.PUR.001 CAN-Bus CFBUS.PUR.021 CFBUS.PUR.022 CFBUS.PUR.045
(2)

Number of cores and conductor nominal cross section [mm2] (2x0,25)C (2x0,5)C (2x(2x0,5))C (4x(2x0,15))C

External diameter in mm approx. 8,0 8,5 8,5 7,0

Copper index [kg/km] 22 27 38 34

Weight [kg/km]

67 76 89 62

Ethernet/CAT5/GigE
The Chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Part No. Profibus CFBUS.PUR.001 CAN-Bus CFBUS.PUR.021 CFBUS.PUR.022 Ethernet/CAT5/GigE CFBUS.PUR.045

Characteristic in approx. 150 120 120 100

Number of cores Colour code nominal cross section [mm2] (2x0,25)C (2x0,5)C (2x(2x0,5))C (4x(2x0,15))C red, green white, brown white, green, brown, yellow (star-quad stranding) white-blue/blue, white-orange/orange, white-green/green, white-brown/brown

wave impedance and conductor

Order example: CFBUS.PUR.001 in your desired length (0,5 m steps) CFBUS.PUR Chainflex series .001 Code Bus type

Please use www.chainflex.eu/en/CFBUSPUR for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods * Die Lieferzeit bedeutet die Zeit bis zum Versand der Ware

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFBUSPUR (for up to 10 cuts of the same type) 4.121

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Bus cable

CFBUS
TPE 10-12.5 x d

TPE Bus cable Chainflex CFBUS


G for maximum load requirements G TPE outer jacket G shielded G oil-resistant G bio-oil-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant

Especially bendingresistant fine-wire stranded conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m, Class 4 -40 C to +70 C, minimum bending radius 5 x d -35 C to +70 C, minimum bending radius 10-12.5 x d

Cores each stranded in especially short pitch

Travel distance

UV-resistant Nominal voltage Testing voltage Oil


Highly flexible braided copper shield

Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4.

Gusset-filled extruded

Flame-retardant Silicon-free
Pressure extruded, flame-retard TPE blend

According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228).

Conductor

Core insulation Core stranding

According to bus specification. According to bus specification. According to bus specification Schedule delivery program

Class 6.4.4

Core identification Inner jacket Overall shield Outer jacket


Image exemplary.

TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Red lilac (similar to RAL 4001)

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.122

Price index

Class 6.4.4
UL/CSA CE DESINA Lead free Clean room Style 1589 and 21371, 30 V, 80 C Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CFBUS
TPE 10-12.5 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications without direct sun radiation n especially for freely suspended and gliding travel distances up to 400 m n bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Test data Page 4.28

FireWire cable for moving energy supplies in digital camera technology.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFBUS (for up to 10 cuts of the same type)

4.123

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Bus cable

CFBUS
TPE 10-12.5 x d

TPE Bus cable Chainflex CFBUS


G for maximum load requirements G TPE outer jacket G shielded G oil-resistant G bio-oil-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant
Delivery program Part No. Number of cores and conductor nominal cross section [mm ]
2

External diameter in mm approx.

Copper index [kg/km] 23 96 58 42 74 33 36 45 33 96 44 33 46 53 35 35 77 42 37 26 32 33

Weight [kg/km]

Profibus (minimum bending radius 10 x d) CFBUS.001 CFBUS.002 CFBUS.003 CFBUS.010 CFBUS.011 CFBUS.020(2) CFBUS.021 CFBUS.022(2) CFBUS.030 CFBUS.031 CFBUS.035 CFBUS.040(2) CFBUS.041 CFBUS.042(1) CFBUS.044
Image exemplary.

(2x0,25)C 4x1,5+(2x0,25)C 3x0,75+(2x0,25)C (3x(2x0,25))C (3x(2x0,25)+3x1,0)C (2x(2x0,25))C (2x0,5)C (2x(2x0,5))C Drop Trunk (1x2xAWG24+1x2xAWG22)C (1x2xAWG18+1x2xAWG15)C (3xAWG20)C (2x(2x0,25))C (4x(2x0,25))C (5x(2x0,25))C (4x(2x0,15))C (4x(2x0,15))C (4x(2x0,14)C)C (2x(2x0,15)C+2x(0,34)C) (4x0,38)C (2x0,5+1x(2x0,08))C (2x0,5+1x(2x0,24))C (4x2x0,08+2x0,08+3x0,08)C

8,5 12,5 11,0 8,5 10,0 6,5 8,5 8,5 7,5 11,5 8,5 7,0 10,0 10,5 8,0 8,0 10,0 7,5 7,5 5,0 6,0 9

70 175 121 83 135 66 77 83 65 110 90 43 101 106 79 79 131 81 71 45 56 92 NEW* NEW*

Interbus (minimum bending radius 10 x d)

CAN-BUS/Fieldbus (minimum bending radius 10 x d)

DeviceNet (minimum bending radius 10 x d)

CC-Link (Biegeradius min. 10 x d) Ethernet/CAT5/GigE (minimum bending radius 12,5 x d)

CFBUS.045 CFBUS.050 CFBUS.055 CFBUS.060 USB (minimum bending radius 12,5 x d)

Ethernet/CAT6 (minimum bending radius 12,5 x d) FireWire (minimum bending radius 12,5 x d) Profinet (minimum bending radius 12,5 x d)

Class 6.4.4

CFBUS.065 CFBUS.066 CFBUS.070

DVI (minimum bending radius 12,5 x d)


(1) Delivery time upon inquiry The Chainflex types marked with (2) are cables designed as a star-quad. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

... no minimum order quantity


4.124
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.4.4
Delivery program Part No. Profibus CFBUS.001 CFBUS.002 CFBUS.003 Interbus CFBUS.010 CFBUS.011 CAN-BUS/Feldbus CFBUS.020 CFBUS.021 CFBUS.022 DeviceNet CFBUS.030 Drop CFBUS.031 Trunk Characteris- Number of cores Colour code tic wave and conductor impedance nominal cross in approx. section [mm2] 150 (2x0,25)C 150 4x1,5+ (2x0,25)C 150 3x0,75+ (2x0,25)C 100 100 (3x(2x0,25))C (3x1,0+ 3x(2x0,25))C (2x(2x0,25))C (2x0,5)C (2x(2x0,5))C (1x2xAWG24)+ (1x2xAWG22)C (1x2xAWG18)+ (1x2xAWG15)C (3xAWG20)C (2x(2x0,25))C (4x(2x0,25))C (5x(2x0,25))C (4x(2x0,15))C (4x(2x0,15))C red, green black with white numbers red/green black, blue, green-yellow red/green white/brown, green/yellow, gray/pink red, blue, green-yellow white/brown, green/yellow, gray/pink white, green, brown, yellow (star-quad stranding) white, brown white, green, brown, yellow (star-quad stranding) white/blue red/black white/blue red/black white, yellow, blue white, green, brown, yellow (star-quad stranding) white/brown, green/yellow, gray/pink, blue/red white/brown, green/yellow, gray/pink, blue/red, black/violet white/brown, green/yellow, gray/pink, blue/red white-blue/blue, white-orange/orange, white-green/green, white-brown/brown white/blue, white/orange, white/green, white/brown orange/blue, green/red black, white white, yellow, blu, orange (star-quad stranding) red, black white/green red, black white/green 4x white/yellow with elementjacket in blue, black, white, red white/brown, green, yellow, gray

CFBUS
TPE 10-12.5 x d

120 120

CC-Link CFBUS.035 Ethernet/CAT5/GigE CFBUS.040 CFBUS.041 CFBUS.042 CFBUS.044 CFBUS.045 Ethernet/CAT6 CFBUS.050 FireWire CFBUS.055 Profinet CFBUS.060 USB CFBUS.065 CFBUS.066 DVI CFBUS.070

110 100 100 100 100 100

100 100

(4x(2x0,14)C)C 2x(2x0,15)C+ 2x(0,34)C (4x0,38)C 2x0,5 2x0,08 2x0,5 2x0,24 (4x2x0,08+ 2x0,08+3x0,08)C

100 90 90

100

Technical information
The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in E-Chains. High proofness to oil and lubricants is as secured as protection against electromagne tical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness. In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call!

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFBUS (for up to 10 cuts of the same type)

4.125

Fax +49-2203-96 49-222

120 120 120

Tel. +49-2203-96 49-0

Bus cable

CF11.LC
TPE 10 x d

TPE Bus cable Chainflex CF11.LC (low capacitance)


G for maximum load requirements G TPE outer jacket G shielded G oil-resistant G bio-oil-resistant G PVC-free/halogen-free G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance -35 C to +70 C, minimum bending radius 10 x d -40 C to +70 C, minimum bending radius 5 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m, Class 4 High 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification. According to bus specification. According to bus specification Schedule delivery program

Especially bendingresistant fine-wire stranded conductor

Cores each stranded in especially short pitch

UV-resistant Nominal voltage

Gusset-filled extruded

Testing voltage Oil

Highly flexible braided copper shield

Silicon-free

Halogen-free Conductor
Pressure extruded, halogen-free TPE blend

Core insulation Core stranding Core identification

Class 6.4.4

Inner jacket Overall shield Outer jacket

TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) Following 2006/95/EG

CE
Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.126

Price index

Class 6.4.4
Lead free Clean room Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

CF11.LC
TPE 10 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m n bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Delivery program Part No. Interbus CF11.02.03.02.IB-S CF11.02.03.02.10.03.IB-S CAN-Bus CF11.05.01.02.LC CF11.05.02.02.LC(2) Profibus CF11.02.02.02.PBA.LC(2)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 8,5 10,0 8,5 8,5 8,5

Copper index [kg/km] 42 74 36 45 33

Weight [kg/km] 83 135 77 83 80

(3x(2x0,25))C (3x(2x0,25)+3x1,0)C (2x0,5)C (2x(2x0,5))C (2x(2x0,25))C

The Chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Part No. Interbus CF11.02.03.02.IB-S CF11.02.03.02.10.03.IB-S CAN-Bus CF11.05.01.02.LC CF11.05.02.02.LC Profibus CF11.02.02.02.PBA.LC

Characteris- Number of cores Colour code tic wave impedance approx. [ ] 100 100 and conductor nominal cross section [mm2] (3x(2x0,25))C (3x2x0,25+ 3x1,0)C 120 120 150 (2x0,5)C (2x(2x0,5))C (2x(2x0,25))C white/brown, green/yellow, gray/pink white/brown, green/yellow, gray/pink red, blue, green-yellow white, brown white, green, brown, yellow (star-quad stranding) green/red, yellow/brown

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF11LC (for up to 10 cuts of the same type)

4.127

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Bus cable

CF11.LC.D
TPE 10 x d

TPE Bus cable Chainflex CF11.LC.D (low capacitance)


G for maximum load requirements G TPE outer jacket G shielded G PVC-free/halogen-free G oil-resistant G bio-oil-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance

Especially bendingresistant fine-wire stranded conductor

-35 C to +70 C, minimum bending radius 10 x d -40 C to +70 C, minimum bending radius 5 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m, Class 4 Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification. According to bus specification. According to bus specification Schedule delivery program

Cores each stranded in especially short pitch

UV-resistant Nominal voltage

Gusset-filled extruded

Testing voltage Oil Silicon-free

Highly flexible braided copper shield

Halogen-free Conductor

Pressure extruded, halogen-free TPE blend

Core insulation Core stranding Core identification Inner jacket

TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Red lilac (similar to RAL 4001) Following 2006/95/EG According to VDW, DESINA standardisation

Class 6.4.4

Overall shield Outer jacket

CE DESINA

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.128

Price index

Class 6.4.4
Lead free Clean room Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

CF11.LC.D
TPE 10 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications without direct sun radiation n especially for freely suspended and gliding travel distances up to 400 m n bus connection cable for storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications Delivery program Part No. Profibus CF11.02.01.02.PBA.LC.D CF11.02.02.07.03.PBA.LC.D CF11.02.02.15.04.PBA.LC.D Fieldbus (CAN-Bus) CF11.02.02.02.LC.D(2) CF11.05.01.02.LC.D (2x(2x0,25))C (2x0,5)C 6,5 8,5 33 36 66 77 Number of cores and conductor nominal cross section [mm ]
2

External diameter approx. [mm] 8,5 11,0 12,5

Copper index [kg/km] 23 58 96

Weight [kg/km] 70 121 175

(2x0,25)C 3x0,75+(2x0,25)C 4x1,5+(2x0,25)C

The Chainflex types marked with (2) are cables designed as a star-quad. Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Part No. Profibus CF11.02.01.02.PBA.LC.D CF11.02.02.07.03.PBA.LC.D CF11.02.02.15.04.PBA.LC.D Fieldbus (CAN-Bus) CF11.02.02.02.LC.D CF11.05.01.02.LC.D

Characteris- Number of cores Colour code tic wave impedance approx. [ ] 150 150 150 and conductor nominal cross section [mm2] (2x0,25)C 3x0,75+ (2x0,25)C 4x1,5+ (2x0,25)C 120 120 (2x(2x0,25))C (2x0,5)C red/green black with white numbers red/green black, blue, green-yellow red/green white, green, brown, yellow (star-quad stranding) white/brown

Order example: CF11.02.03.02.IB-S in your desired length (0,5 m steps) CF11.LC Chainflex series .02 Code nominal cross section .03 Number of pairs .02 Identification pairs .IB-S Special identification

Please use www.chainflex.eu/en/CF11LCD for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Test data Page 4.28

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF11LCD (for up to 10 cuts of the same type)

4.129

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Bus cable

CF14
TPE 12,5 x d

TPE Bus cable Chainflex CF14 CAT5


G Ethernet special cable for maximum load requirements G TPE outer jacket G oil-resistant G bio-oil-resistant G PVC-free/halogen-free G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance

Especially bendingresistant fine-wire stranded conductor

-35 C to +70 C, minimum bending radius 12,5 x d -40 C to +70 C, minimum bending radius 7,5 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. 19-wire conductor consisting of bare copper wires in especially bending-resistant braiding quality. Special PP-isolating mixture. 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100 TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Red lilac (similar to RAL 4001) Following 2006/95/EG

2 cores each stranded in especially short pitch, PP special insulation

UV-resistant Nominal voltage Testing voltage Oil


Highly flexible braided copper shield

Gusset-filled extruded

Silicon-free

Halogen-free
Pressure extruded, halogen-free TPE blend

Conductor

Core insulation Core stranding

Core identification

Class 6.3.4

Inner jacket Overall shield Outer jacket

Image exemplary.

CE

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.130

Price index

Class 6.3.4
DESINA Lead free Clean room According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

CF14
TPE 12,5 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications without direct sun radiation n especially for freely suspended and gliding travel distances up to 100 m n ethernet cable for Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

Delivery program Part No. Ethernet CAT5 CF14.02.02.02.CAT5(2) CF14.02.04.02.CAT5 CF14.02.05.02.CAT5

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 7,0 10,0 10,5

Copper index [kg/km] 33 46 53

Weight [kg/km] 43 101 106

(2x(2x0,25))C (4x(2x0,25))C (5x(2x0,25))C

The Chainflex types marked with (2) are cables designed as a star-quad. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Part No. Ethernet CAT5 CF14.02.02.02.CAT5 CF14.02.04.02.CAT5 CF14.02.05.02.CAT5

Characteris- Number of cores Colour code tic wave and conductor impedance nominal cross approx. [ ] section [mm2] 100 100 100 (2x(2x0,25))C (4x(2x0,25))C (5x(2x0,25))C white, green, brown, yellow (star-quad stranding) white/brown, green/yellow, gray/pink, blue/red white/brown, green/yellow, gray/pink, blue/red, black/violet

Order example: CF14.02.02.02.CAT5 in your desired length (0,5 m steps) CF14 CAT5 Chainflex series .02 Code nominal cross section .02 Number of pairs .02 Identification pairs .CAT5 CAT5 identification

Please use www.chainflex.eu/en/CF14 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Test data Page 4.26 More CAT5/CAT6 cables Page 4.122, CFBUS

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF14 (for up to 10 cuts of the same type)

4.131

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Bus cable

CF211
PVC 10 x d

PVC Measuring system cable Chainflex CF211


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Center element for high tensile stresses

Fine-wire special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance

-5 C to +70 C, minimum bending radius 10 x d -20 C to +70 C, minimum bending radius 5 x d 5 m/s, 3 m/s 50 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 30 V 500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. According to measuring system specification. According to measuring system specification Schedule delivery program Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Foil taping over the external layer. TPE mixture adapted to suit the requirements in Energy Chains over pair shield. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Silver gray (similar to RAL 7001)

Cores each stranded with short pitch

Nominal voltage Testing voltage Oil

Flame-retardant
Highly flexible braided copper shield

Silicon-free Conductor

Core insulation
Pressure extruded

Core stranding Core identification Element shield

Intermediate sheath

Class 5.3.2

Element jacket Overall shield Outer jacket

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.132

Price index

Class 5.3.2
UL/CSA CEI CE Lead free Clean room Style 1589 and 2502, 30 V, 80 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1

CF211
PVC 10 x d

Typical application area


n for high load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, handling, indoor cranes

Three Energy Chain Systems in several axes fitted with specially cables from igus. E-Chain: System E4/00 and System E4/0

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF211M (for up to 10 cuts of the same type)

4.133

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF211
PVC 10 x d

PVC Measuring system cable Chainflex CF211


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Delivery program* Part No. CF211.001 CF211.002 CF211.006 CF211.009 CF211.010 CF211.011 CF211.014 CF211.016 CF211.017 CF211.018 CF211.019 CF211.027

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+ (4x0,14)+(2x0,5))C (3x(2x0,14)C+2x(0,5)C)C (3x(2x0,14)C+2x0,5+ 4x0,14+4x0,23)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x1,0)C (4x(2x0,34)+4x0,5)C (4x(2x0,25)C+1x2x0,5)C (3x(2x0,25)C)C (4x(2x0,14)+ 4x1,0+(4x0,14)C)C (2x(2x0,25)+2x0,5)C (3x0,25+ 3x(2x0,25)C+2x1,0)C (5x(2x0,14)+2x0,5)C

External diameter approx. [mm] 9,0 9,0 9,5 9,0 9,5 9,0 13,0 11,0 9,0 7,0 9,0 9,0

Copper index [kg/km] 61 63 72 51 74 75 84 85 85 41 82 45

Weight [kg/km]

100 110 120 111 141 135 211 170 124 62 115 102

Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Image exemplary.

Order example: CF211.001 in your desired length (0,5 m steps) CF211 Chainflex series .001 Code Measuring system

Please use www.chainflex.eu/en/CF211M for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Class 5.3.2

... no minimum order quantity


4.134
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 5.3.2
Delivery program Part No. CF211.001 Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+(4x0,14)+(2x0,5))C 3x(2x0,14)C yellow/green, black/brown, red/orange 4x0,14 2x0,5 CF211.002 2x(0,5)C 4x0,14 4x0,23 2x0,5 CF211.009 CF211.010 CF211.011 CF211.014 CF211.016 CF211.017 (4x(2x0,25)+2x0,5)C 4x(2x0,25) 2x0,5 (4x(2x0,25)+2x1,0)C 4x(2x0,25) 2x1,0 (4x(2x0,34)+4x0,5)C 4x(2x0,34) 4x0,5 2x0,5 (4x(2x0,14)+4x1,0+(4x0,14)C)C (4x0,14)C 4x(2x0,14) 4x1,0 CF211.018 CF211.019 (2x(2x0,25)+2x0,5)C 2x(2x0,25) 2x0,5 (3x0,25) (2x1,0) CF211.027 (5x(2x0,14)+2x0,5)C 5x(2x0,14) (2x0,5) gray, blue, white-yellow, white-black brown-red, brown-blue black, red gray, blue, white-yellow, white-black brown-yellow, brown-gray, green-black, green-red brown-red, brown-blue brown/green, blue/violet, gray/pink, red/black white, brown brown/green, blue/violet, gray/pink, red/black white, brown black/brown, red/orange, yellow/green, blue/violet blue-white, black-white, red-white, yellow-white black (numeral printing 1-2) blue-black, red-black, yellow-black, green-black red/black, green/brown, yellow/violet, pink/gray white-green, brown-green, blue, white red/black, gray/pink white, brown blue, yellow, violet white, brown green/brown, gray/yellow, white/violet, black/red, blue/pink white-green, white-red Core group Colour code

CF211
PVC 10 x d

(3x(2x0,14)C+2x(0,5)C)C 3x(2x0,14)C green/yellow, black/brown, red/orange

CF211.006 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 3x(2x0,14)C green/yellow, black/brown, red/orange

(4x(2x0,25)C+1x2x0,5)C 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red (3x(2x0,25)C)C 3x(2x0,25)C white/brown, green/yellow, gray/pink

(3x0,25+3x(2x0,25)C+2x1,0)C 3x(2x0,25)C brown/green, pink/gray, red/black

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF211M (for up to 10 cuts of the same type)

4.135

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF113.D
PUR 10 x d

PUR Measuring system cable Chainflex CF113.D


G for maximum load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant G PVC-free/halogen-free
Temperature range moved Temperature range fixed -40 C to +80 C, minimum bending radius 5 x d v max. unsupported/gleitend 5 m/s, 3 m/s a max. Travel distance 50 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 UV-resistant Nominal voltage Testing voltage Oil Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3 Offshore Flame-retardant Halogen-free Silicon-free Conductor MUD-resistant following NEK 606 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1 Following EN 50267-2-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). -20 C to +80 C, minimum bending radius 10 x d

Especially bendingresistant fine-wire stranded conductor

Highly flexible braided copper shield

Center element for high tensile stresses

Cores each stranded in especially short pitch

Gusset-filled extruded

Highly flexible braided copper shield

Pressure extruded PUR blend

Class 6.3.3

Core insulation Core stranding Core identification Element shield


Image exemplary.

Mechanically high-quality PP mixture. According to measuring system specification According to measuring system specification Schedule Delivery Program Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.136

Price index

Class 6.3.3
Inner jacket Overall shield Outer jacket TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Yellow green (similar to RAL 6018) UL/CSA CEI CE DESINA Lead free Clean room Style 1589 and 20236, 30 V, 80 C Following CEI 20-35 Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

CF113.D
PUR 10 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil n indoor and outdoor applications without direct sun radiation n especially for freely suspended and gliding travel distances up to 100 m n Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, indoor cranes, low-temperature applications

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF113D (for up to 10 cuts of the same type) 4.137

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF113.D
PUR 10 x d

PUR Measuring system cable Chainflex CF113.D


G for maximum load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant G PVC-free/halogen-free
Delivery program Part No. CF113.001.D CF113.002.D CF113.003.D(1) CF113.004.D CF113.005.D CF113.006.D CF113.007.D CF113.008.D CF113.009.D CF113.010.D(1) CF113.011.D(1) CF113.012.D CF113.013.D CF113.015.D CF113.016.D(1)
(1) (1)

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+ (4x0,14)+(2x0,5))C (3x(2x0,14)C+2x(0,5)C)C (3x(2x0,14)+2x1,0)C (2x(2x2x0,14)+ (4x0,14)C+4x0,5)C (4x(2x0,14)+4x0,5)C (3x(2x0,14)C+(4x0,14)+ (4x0,23)+(2x0,5))C (2x2x0,34)C (3x(2x0,25))C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x1,0)C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+(3x0,14)C+ 6x0,14+2x0,5)C

External diameter approx. [mm] 10,5 10,5 8,5 11,5 9,5 11,0 6,0 8,0 9,5 9,5 10,5 11,5 9,5 11,5 9,5 9,5 11,5 9,0 11,5 11,0

Copper index [kg/km] 72 74 55 82 61 84 29 33 60 72 87 90 63 86 61 59 105 38 96 92

Weight [kg/km]

172 185 124 195 144 197 64 81 137 159 199 220 153 210 140 141 241 114 225 210 NEW* NEW*

(1)

(3x(2x0,14)C+2x0,5)C (4x(2x0,25)C+2x0,5)C (4x(2x0,14)+4x0,5)C (3x(2x0,25)C)C (4x(2x0,14)+ (4x0,14)C+4x1,0)C (2x(2x0,25)+2x0,5)C (3x(2x0,25)C+ (3x0,25)+2x1,0)C (3x(2x0,5+2x0,25)+(4x0,25))C

CF113.014.D(1)

Image exemplary.

CF113.017.D / CF113.018.D /

(1) (4)

(1) (4)

CF113.019.D(1)/(4) CF113.021.D(1)

Class 6.3.3

(1) Delivery time upon inquiry (4) manufactured without inner jacket Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

More types

Page 4.140

... no minimum order quantity


4.138 eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.3.3
Delivery program Part No. CF113.001.D Number of cores and conductor Core group Colour code nominal cross section [mm2] (3x(2x0,14)C+(4x0,14)+(2x0,5))C 3x(2x0,14)C yellow/green, black/brown, red/orange (4x0,14) (2x0,5) CF113.002.D CF113.003.D CF113.004.D 2x(0,5)C (3x(2x0,14)+2x1,0)C 3x(2x0,14) 2x1,0 (4x0,14)C 4x0,5 CF113.005.D (4x(2x0,14)+4x0,5)C 4x(2x0,14) 4x0,5 (4x0,14) (4x0,23) (2x0,5) CF113.007.D CF113.008.D CF113.009.D CF113.010.D CF113.011.D (2x2x0,34) 4x0,34 (3x(2x0,25))C 3x(2x0,25) (4x(2x0,25)+2x0,5)C 4x(2x0,25) 2x0,5 (4x(2x0,25)+2x1,0)C 4x(2x0,25) 2x1,0 (4x(2x0,34)+4x0,5)C 4x(2x0,34) 4x0,5 (3x0,14)C 6x0,14 2x0,5 CF113.013.D CF113.014.D CF113.015.D CF113.016.D CF113.017.D 2x0,5 2x0,5 (4x(2x0,14)+4x0,5)C 4x(2x0,14) 4x0,5 (4x(2x0,14)+(4x0,14)C+4x1,0)C 4x(2x0,14) (4x0,14)C 4x1,0 CF113.018.D CF113.019.D (2x(2x0,25)+2x0,5)C 2x(2x0,25) 2x0,5 (3x0,25) 2x1,0 CF113.021.D (3x(2x0,5+2x0,25)+(4x0,25))C 3x(2x0,25) 3x(2x0,5) (4x0,25) gray, blue, white-yellow, white-black brown-red, brown-blue black, red white/brown, green/yellow, gray/pink blue, red yellow-black, red-black, green-black, blue-black brown-green, white-green, blue, white white/brown, green/yellow, gray/pink, blue/red black, violet, gray-pink, red-blue blue, gray, white-black, white-yellow brown-yellow, brown-gray, green-black, green-red brown-red, brown-blue white, green, brown, yellow (star-quad stranding) white/brown, green/yellow, gray/pink brown/green, blue/violet, gray/pink, red/black white, brown brown/green, blue/violet, gray/pink, red/black white, brown black/brown, red/orange, yellow/green, blue/violet blue-white, black-white, red-white, yellow-white red, green, brown blue, gray, gray, yellow, pink, violet brown-red, brown-blue red, blue black (numeral printing 1-2) brown/green, violet/yellow, gray/pink, red/black blue, white, brown-green, white-green red/black, green/brown, yellow/violet, pink/gray blue-black, red-black, yellow-black, green-black white-green, brown-green, blue, white red/black, gray/pink white, brown blue, yellow, violet white, brown white/yellow, white/gray, black/orange black (numeral printing 1-6) white, gray, brown, black

CF113.D
PUR 10 x d

(3x(2x0,14)C+2x(0,5)C)C 3x(2x0,14)C green/yellow, black/brown, red/orange

(2x(2x2x0,14)+ (4x0,14)C+4x0,5)C 2x(2x2x0,14) brown/green, violet/yellow, gray/pink, red/black

CF113.006.D (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 3x(2x0,14)C green/yellow, brown/black, red/orange

CF113.012.D (3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C 3x(2x0,14)C green/yellow, white/gray, blue/red

(3x(2x0,14)C+2x0,5)C 3x(2x0,14)C white/brown, green/yellow, gray/pink (4x(2x0,25)C+2x0,5)C 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red

(3x(2x0,25)C)C 3x(2x0,25)C white/brown, green/yellow, gray/pink

(3x(2x0,25)C+(3x0,25)+2x1,0)C 3x(2x0,25)C brown/green, gray/pink, red/black

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF113D (for up to 10 cuts of the same type) 4.139

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF113.D
PUR 10 x d

PUR Measuring system cable Chainflex CF113.D


G for maximum load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant G PVC-free/halogen-free
Delivery program Part No. CF113.022.D(1) CF113.025.D(1) CF113.027.D CF113.028.D CF113.032.D
(1) (1)

Number of cores and conductor nominal cross section [mm2] (5x0,5+(2x0,25))C (3x(2x0,14)C+(2x0,5)C)C (5x(2x0,14)+2x0,5)C (2x(2x0,15)+(2x0,38))C 3x(2x0,14)C+(3x0,14)C 4x(2x0,14)C+2x(1,0)C 3x(2x0,14)C+ (4x0,14)C+2x(2x0,5)C

External diameter approx. [mm] 8,5 11,0 9,0 7,5 9,5 11,5 12,5

Copper index [kg/km] 50 73 52 47 61 97 105

Weight [kg/km] 121 180 121 72 148 237 199 NEW* NEW* NEW*

CF113.033.D(1) CF113.034.D
(1)

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Class 6.3.3

Image exemplary.

... no minimum order quantity


4.140 eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.3.3
Delivery program Part No. CF113.022.D CF113.025.D CF113.027.D CF113.028.D CF113.032.D CF113.033.D CF113.034.D Number of cores and conductor Core group nominal cross section [mm2] (5x0,5+(2x0,25))C 5x0,5 (2x0,25) (3x(2x0,14)C+(2x0,5)C)C 3x(2x0,14) (2x0,5)C (5x(2x0,14)+2x0,5)C 5x(2x0,14) 2x0,5 (2x(2x0,15)+(2x0,38))C 2x(2x0,15) (2x0,38) (3x0,14)C 2x(1,0)C (4x0,14)C 2x(2x0,5)C blue, green, yellow, gray, pink white, brown green/yellow, blue/red, gray/pink white, brown green/brown, gray/yellow, white/violet, black/red, blue/pink white-green, white-red green/yellow, pink/blue red, black black, gray, pink white, brown yellow, red-black, yellow-black, red black/brown, black/white Colour code

CF113.D
PUR 10 x d

3x(2x0,14)C+(3x0,14)C 3x(2x0,14)C yellow/black, red/black, green/black 4x(2x0,14)C+2x(1,0)C 4x(2x0,14)C yellow/black, red/black, green/black, blue/black 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 3x(2x0,14)C green/black, violet/black, blue/black

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF113D (for up to 10 cuts of the same type) 4.141

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF111.D
TPE 12 x d

TPE Measuring system cable Chainflex CF111.D


G for medium load requirements G TPE outer jacket G shielded G oil-resistant G bio-oil-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported a max. Travel distance

Center element for high tensile stresses

-35 C to +100 C, minimum bending radius 12 x d -40 C to +100 C, minimum bending radius 6 x d 2 m/s 30 m/s2 Freely suspended travel distances, Class 1

Fine-wire special conductor

Cores each stranded with short pitch

UV-resistant Nominal voltage Testing voltage Oil


Bending-resistant braided copper shield

Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Very finely stranded special cores of particularly high-flex design made of bare copper wires. Mechanically high-quality PP mixture. According to measuring system specification. According to measuring system specification Schedule delivery program Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Foil taping over the external layer. Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Yellow green (similar to RAL 6018)

Flame-retardant Silicon-free
Pressure extruded, flame-retard TPE blend

Conductor

Core insulation Core stranding Core identification Element shield

Class 4.1.4

Intermediate sheath Overall shield Outer jacket

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.142

Price index

Class 4.1.4
UL/CSA CEI CE DESINA Lead free Clean room Style 1589 and 21371, 30 V, 80 C Following CEI 20-35 Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CF111.D
TPE 12 x d

n for medium load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications without direct sun radiation n especially for freely suspended travel distances n machining units/machine tools, low temperature applications

The ReadyChain systems from igus are completely pre-assembled with Chainflex cables, hoses, screw attachments, metal parts etc.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF111D (for up to 10 cuts of the same type)

4.143

Fax +49-2203-96 49-222

Typical application area


Tel. +49-2203-96 49-0

Measuring system cable

CF111.D
TPE 12 x d

TPE Measuring system cable Chainflex CF111.D


G for high load requirements G TPE outer jacket G shielded G oil-resistant G bio-oil-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant
Delivery program Part No. CF111.001.D CF111.004.D CF111.006.D CF111.011.D CF111.015.D CF111.021.D CF111.022.D CF111.027.D(1) CF111.035.D Number of cores and conductor nominal cross section [mm ]
2

External diameter approx. [mm] 8,5 10,5 10,0 9,5 8,0 10,0 8,0 9,0 12,5

Copper index [kg/km] 56 72 69 69 49 79 49 54 118

Weight [kg/km]

(3x(2x0,14)C+ (4x0,14)+(2x0,5))C (4x(2x0,14)+ (4x0,14)C+4x0,5)C (3x(2x0,14)C+2x0,5+ 4x0,14+4x0,23)C (4x(2x0,34)+4x0,5)C (4x(2x0,14)+4x0,5)C (6x0,5+5x2x0,25)C (5x0,5+1x2x0,25)C (5x(2x0,14)+2x0,5)C (4x(2x0,25)C+2x(2x0,5))C 112 106 76 125 78 109 202 113 87

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF111.021.D in your desired length (0,5 m steps) CF111.D Chainflex series .001 Code Measuring system

Please use www.chainflex.eu/en/CF111D for your online order.


Image exemplary.

Delivery time 24h or today*


* Delivery time means time until shipping of goods

Class 4.1.4

... no minimum order quantity


4.144
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 4.1.4
Part No. CF111.001.D Number of cores and conductor Core group Colour code nominal cross section [mm2] (3x(2x0,14)C+(4x0,14)+(2x0,5))C 3x(2x0,14)C yellow/green, black/brown, red/orange 4x0,14 2x0,5 CF111.004.D (4x(2x0,14)+(4x0,14)C+4x0,5)C 4x(2x0,14) (4x0,14)C 4x0,5 4x0,14 4x0,23 2x0,5 CF111.011.D CF111.015.D CF111.021.D (4x(2x0,34)+4x0,5)C 4x(2x0,34) 4x0,5 (4x(2x0,14)+4x0,5)C 4x(2x0,14) 4x0,5 (6x0,5+5x2x0,25)C (3x0,5) (3x0,5) (5x2x0,25) CF111.022.D CF111.027.D CF111.035.D (5x0,5+1x2x0,25)C (5x0,5) (2x0,25) (5x(2x0,14)+ 5x(2x0,14) 2x0,5)C (2x0,5) 2x(2x0,5))C 2x(2x0,5) gray, blue, white-yellow, white-black brown-red, brown-blue brown/green, violet/yellow, gray/pink, red/black yellow-black, red-black, green-black, blue-black brown-green, white-green, blue, white gray, blue, white-yellow, white-black brown-yellow, brown-gray, green-black, green-red brown-red, brown-blue black/brown, red/orange, yellow/green, blue/violet blue-white, black-white, red-white, yellow-white brown/green, violet/yellow, gray/pink, red/black blue, white, brown-green, white-green black (numeral printing 1-3) red (numeral printing 1-3) yellow/white, gray/white, black/orange, white/brown, black/gray blue, green, yellow, gray, pink white, brown green/brown, gray/yellow, white/violet, black/red, blue/pink white-green, white-red black (numeral printing 1-4)

CF111.D
TPE 12 x d

CF111.006.D (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 3x(2x0,14)C green/yellow, black/brown, red/orange

(4x(2x0,25)C+ 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF111D (for up to 10 cuts of the same type)

4.145

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF11.D
TPE 10 x d

TPE Measuring system cable Chainflex CF11.D


G for maximum load requirements G TPE outer jacket G shielded G twisted-pair G oil- and bio-oil-resistant G PVC-free/halogen-free G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance -35 C to +100 C, minimum bending radius 10 x d -40 C to +100 C, minimum bending radius 5 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m, Class 4 Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality PP mixture. According to measuring system specification. According to measuring system specification Schedule delivery program Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Yellow green (similar to RAL 6018)

Especially bendingresistant fine-wire stranded conductor

Extrem Highly flexible braided copper shield

Center element for high tensile stresses

Cores each stranded in especially short pitch

UV-resistant Nominal voltage Testing voltage

Gusset-filled extruded

Oil Silicon-free

Highly flexible braided copper shield

Halogen-free Conductor
Pressure extruded, halogen-free TPE blend

Core insulation Core stranding Core identification Element shield

Class 6.4.4

Inner jacket Overall shield Outer jacket

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.146

Price index

Class 6.4.4
CE DESINA Lead free Clean room Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CF11.D
TPE 10 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications without direct sun radiation n especially for freely suspended and gliding travel distances up to 400 m n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

Pre-assembled igus energy supply systems for machine tool manufacture. E-Chain: System E4/4

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF11D (for up to 10 cuts of the same type)

4.147

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF11.D
TPE 10 x d

TPE Measuring system cable Chainflex CF11.D


G for maximum load requirements G TPE outer jacket G shielded G twisted-pair G oil- and bio-oil-resistant G PVC-free/halogen-free G hydrolysis-resistant and microbe-resistant

Delivery program* Part No. CF11.001.D CF11.002.D CF11.003.D CF11.004.D CF11.005.D CF11.006.D(4) CF11.007.D CF11.008.D CF11.009.D CF11.010.D CF11.011.D CF11.012.D CF11.013.D CF11.014.D(1) CF11.015.D CF11.016.D(1)
Image exemplary.

Number of cores and conductor nominal cross section [mm2] (3x(2x0,14)C+ (4x0,14)+(2x0,5))C (3x(2x0,14)C+2x(0,5)C)C (3x(2x0,14)+2x1,0)C (2x(2x2x0,14)+ (4x0,14)C+4x0,5)C (4x(2x0,14)+4x0,5)C (3x(2x0,14)C+(4x0,14)+ (4x0,23)+(2x0,5))C (2x2x0,34)C (3x(2x0,25))C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x1,0)C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+ (3x0,14)C+6x0,14+2x0,5)C (3x(2x0,14)C+2x0,5)C (4x(2x0,25)C+2x0,5)C (4x(2x0,14)+4x0,5)C (3x(2x0,25)C)C (4x(2x0,14)+ (4x0,14)C+4x1,0)C

External diameter approx. [mm] 10,5 10,5 8,5 11,5 9,5 11,0 6,0 7,5 9,5 9,5 10,5 11,5 9,5 11,5 9,5 9,5 11,5 7,0 11,5

Copper index [kg/km] 72 74 55 82 61 84 29 33 60 72 87 90 63 86 61 59 105 36 96

Weight [kg/km]

168 180 118 188 137 193 62 77 131 153 192 213 145 203 133 138 234 72 218 NEW* NEW*

CF11.017.D CF11.018.D

(4)

(4)

(2x(2x0,25)+2x0,5)C (3x(2x0,25)C+ (3x0,25)+2x1,0)C

CF11.019.D(4)

(1) Delivery time upon inquiry (4) manufactured without inner jacket Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Class 6.4.4

More types

Page 4.150

... no minimum order quantity


4.148
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.4.4
Part No. CF11.001.D Number of cores and conductor Core group Colour code nominal cross section [mm2] (3x(2x0,14)C+(4x0,14)+(2x0,5))C 3x(2x0,14)C yellow/green, black/brown, red/orange (4x0,14) (2x0,5) CF11.002.D CF11.003.D CF11.004.D 2x(0,5)C (3x(2x0,14)+2x1,0)C 3x(2x0,14) 2x1,0 (4x0,14)C 4x0,5 CF11.005.D (4x(2x0,14)+4x0,5)C 4x(2x0,14) 4x0,5 (4x0,14) (4x0,23) (2x0,5) CF11.007.D CF11.008.D CF11.009.D CF11.010.D CF11.011.D (2x(2x0,34)C 4x0,34 (3x(2x0,25))C 3x(2x0,25) (4x(2x0,25)+2x0,5)C 4x(2x0,25) 2x0,5 (4x(2x0,25)+2x1,0)C 4x(2x0,25) 2x1,0 (4x(2x0,34)+4x0,5)C 4x(2x0,34) 4x0,5 (3x0,14)C 6x0,14 2x0,5 CF11.013.D CF11.014.D CF11.015.D CF11.016.D CF11.017.D 2x0,5 2x0,5 (4x(2x0,14)+4x0,5)C 4x(2x0,14) 4x0,5 (4x(2x0,14)+(4x0,14)C+4x1,0)C 4x(2x0,14) (4x0,14)C 4x1,0 CF11.018.D CF11.019.D (2x(2x0,25)+2x0,5)C 2x(2x0,25) 2x0,5 (3x0,25) 2x1,0 gray, blue, white-yellow, white-black brown-red, brown-blue black, red white/brown, green/yellow, gray/pink blue, red yellow-black, red-black, green-black, blue-black brown-green, white-green, blue, white white/brown, green/yellow, gray/pink, blue/red black, violet, gray-pink, red-blue blue, gray, white-black, white-yellow brown-yellow, brown-gray, green-black, green-red brown-red, brown-blue white, green, brown, yellow (star-quad stranding) white/brown, green/yellow, gray/pink brown/green, blue/violet, gray/pink, red/black white, brown brown/green, blue/violet, gray/pink, red/black white, brown black/brown, red/orange, yellow/green, blue/violet blue-white, black-white, red-white, yellow-white red, green, brown blue, gray, gray, yellow, pink, violet brown-red, brown-blue red, blue black (numeral printing 1-2) brown/green, violet/yellow, gray/pink, red/black blue, white, brown-green, white-green red/black, green/brown, yellow/violet, pink/gray blue-black, red-black, yellow-black, green-black white-green, brown-green, blue, white red/black, gray/pink white, brown blue, yellow, violet white, brown

CF11.D
TPE 10 x d

(3x(2x0,14)C+2x(0,5)C)C 3x(2x0,14)C green/yellow, black/brown, red/orange

(2x(2x2x0,14)+ (4x0,14)C+4x0,5)C 2x(2x2x0,14) brown/green, violet/yellow, gray/pink, red/black

CF11.006.D (3x(2x0,14)C+(4x0,14)+(4x0,23)+(2x0,5))C 3x(2x0,14)C green/yellow, brown/black, red/orange

CF11.012.D (3x(2x0,14)C+(3x0,14)C+6x0,14+2x0,5)C 3x(2x0,14)C green/yellow, white/gray, blue/red

(3x(2x0,14)C+2x0,5)C 3x(2x0,14)C white/brown, green/yellow, gray/pink (4x(2x0,25)C+2x0,5)C 4x(2x0,25)C white/brown, green/yellow, gray/pink, blue/red

(3x(2x0,25)C)C 3x(2x0,25)C white/brown, green/yellow, gray/pink

(3x(2x0,25)C+(3x0,25)+2x1,0)C 3x(2x0,25)C brown/green, gray/pink, red/black

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF11D (for up to 10 cuts of the same type)

4.149

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF11.D
TPE 10 x d

TPE Measuring system cable Chainflex CF11.D


G for maximum load requirements G TPE outer jacket G shielded G twisted-pair G oil- and bio-oil-resistant G PVC-free/halogen-free G hydrolysis-resistant and microbe-resistant

Delivery program* Part No. CF11.021.D CF11.022.D CF11.025.D CF11.027.D CF11.032.D


(1)

Number of cores and conductor nominal cross section [mm2] (3x(2x0,5+2x0,25)+(4x0,25))C (5x0,5+(2x0,25))C (3x(2x0,14)C+(2x0,5)C)C (5x(2x0,14)+2x0,5)C 3x(2x0,14)C+(3x0,14)C 4x(2x0,14)C+2x(1,0)C 3x(2x0,14)C+ (4x0,14)C+2x(2x0,5)C

External diameter approx. [mm] 11,0 8,5 10,5 9,0 9,5 11,5 12,5

Copper index [kg/km] 92 50 73 52 61 97 105

Weight [kg/km] 203 115 174 115 144 230 177 NEW* NEW* NEW*

CF11.033.D(1) CF11.034.D
(1)

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Class 6.4.4

Image exemplary.

... no minimum order quantity


4.150
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.4.4
Part No. CF11.021.D Number of cores and conductor nominal cross section [mm2] (3x(2x0,5+2x0,25)+(4x0,25))C 3x(2x0,25) 3x(2x0,5) (4x0,25) CF11.022.D CF11.025.D CF11.027.D CF11.032.D CF11.033.D CF11.034.D (5x0,5+(2x0,25))C 5x0,5 (2x0,25) (3x(2x0,14)C+(2x0,5)C)C 3x(2x0,14) (2x0,5) (5x(2x0,14)+2x0,5)C 5x(2x0,14) 2x0,5 (3x0,14)C 2x(1,0)C (4x0,14)C 2x(2x0,5)C white/yellow, white/gray, black/orange black (numeral printing 1-6) white, gray, brown, black blue, green, yellow, gray, pink white, brown green/yellow, blue/red, gray/pink white, brown green/brown, gray/yellow, white/violet, black/red, blue/pink white-green, white-red black, gray, pink white, brown yellow, red-black, yellow-black, red black/brown, black/white Core group Colour code

CF11.D
TPE 10 x d

3x(2x0,14)C+(3x0,14)C 3x(2x0,14)C yellow/black, red/black, green/black 4x(2x0,14)C+2x(1,0)C 4x(2x0,14)C yellow/black, red/black, green/black, blue/black 3x(2x0,14)C+(4x0,14)C+2x(2x0,5)C 3x(2x0,14)C green/black, violet/black, blue/black

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF11D (for up to 10 cuts of the same type)

4.151

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Measuring system cable

CF Koax 1
TPE 10 x d

TPE Koax cable Chainflex CF Koax 1


G 75 koax cable for maximum load requirements G TPE outer jacket G oil-resistant G bio-oil-resistant G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max.

Especially bendingresistant special conductor

-35 C to +100 C, minimum bending radius 10 x d -40 C to +100 C, minimum bending radius 7,5 x d 10 m/s, 5 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m, Class 4 High 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Multi-wire; adapted in single-wire diameter and pitch length to suit the requirements in Energy Chains. Special FEP-isolating mixture. Cores stranded in one layer with especially short pitch length. Schedule delivery program Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in Energy Chains. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1

Highly flexible braided copper shield

Travel distance UV-resistant Nominal voltage Testing voltage Oil

Elements stranded with short pitch, FEP special insulation

Silicon-free Conductor

Core insulation Core stranding Core identification Element shield

Gusset-filled extruded, halogen-free TPE mixture

Element jacket Outer jacket

Class 6.4.4

CE Lead free Clean room


Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.152

Price index

Class 6.4.4
Info The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!

CF Koax 1
TPE 10 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

Delivery program Part No. CFKoax 1.01 CFKoax 1.05

Number of cores

External diameter approx. [mm]

Copper index [kg/km] 9 47

Weight [kg/km] 25 135

1 coaxial element 5 coaxial elements

4,5 10,0

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Delivery program Part No. CF Koax 1.01 CF Koax 1.05

Characteristic wave impedance approx. [ ] 75 75

Number of cores 1 coaxial element 5 coaxial elements

Colour code black red, green, blue, white, black

Order example: CFKoax1.01 in your desired length (0,5 m steps) CF Koax1 Chainflex series .01 Number of coaxial elements

Please use www.chainflex.eu/en/CFKOAX1 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Koax cables and other Chainflex cables in platform technology. E-Chain: System E4/4

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFKOAX1 (for up to 10 cuts of the same type)

4.153

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Koax cable

ibre optic cables

Minimum bending radius, moved [factor x d]

Torsion resistant

Chainflex types
Approvals and standards Temperature moved from/to [C] Oil-resistant Chainflex cable Jacket Shield

a max. [m/s2]

v max. [m/s] unsupported

v max. [m/s] gliding

Fibre optic cables (FOC)* CFLK*** CFLG.2H**


NEW**** PUR PUR 12,5 12,5 -20/ +70 -20/ +60   10 10 5 6 20 20 4.158 4.160

CFLG.LB** CFLG. G**

TPE TPE

5 15

-40/ +60 -40/ +60

 

10 10

6 6

20 20

4.162 4.164

* CFROBOT5, torsionable fibre optic cables ** Multimode/gradient fibres *** POF-Fiber/plastic FOC

Page 4.220

Page

**** New in this catalog.

4.155

Info

The safest and often cheapest way to transfer data to machines and plant.
Fault-free communication between all systems in machines and plant that is becoming more and more complex all the time should be a matter of course these days. However, many plant manufacturers or operators have major EMC problems that occur sporadically or even only years later. These problems are often based on conventional bus cables that either have insufficient or unreliable shielding. Alongside igus Chainflex bus cables that already prevent these problems to a large extent, Chainflex glass fibre optic cables provide further advantages for even greater data safety. Fibre optic cables (FOC) do not require a braided shielding that is susceptible to mechanical damage as EMC protection, and are insensitive to EMC on account of their very nature, since industrial conventional interference fields do not have any effect on light signals. In addition, fibre optic cables can be used independently of the system, since a special bus cable is not required for every bus system, rather one FOC type can usually be used to operate any bus system providing the bus system manufacturer provides respective FOC converters. The large number of fibre optic cables in industrial data transmission is also much more manageable than the large number of different field or high-speed buses which require a separate cable for each bus. Thus the following fibre types can be used for industrial data communication, completely independently of the type of field bus used. The fibre type and number depends only on which converters are used and which fibre type the respective manufacturer prescribes. The fibres are defined on the basis of diameter and result in a clear and limited choice. Important fibre types: n Multi-mode fibres 50/125 m 62,5/125 m The ideal fibre for large data volumes and longer transmission lengths in the field of automation. On account of the very low output attenuation (0.8-3 db/km per fibre and light wave length) of these fibre types, transmission lengths of several hundred metres can be realised quite easily. n POF (Plastic fibres) 980/1000 m The ideal and low-cost fibre for short transmission paths. On account of the high output attenuation of the fibre type of 160-230 dB/km, lengths over 15 mm must be avoided in permanent-motion energy chains. n PCF (Polymer Cladded Fibre) 200/230 m The ideal compromise for POF fibre. This plastic-coated quartz glass fibre is a viable alternative for many terminal devices that have been designed for POF. This means greater transmission lengths (100 m and more) are possible without the original POF terminal devices having to be replaced.

... no minimum order quantity


4.156

Info

Chainflex FOC offer the operator the following advantages: 1. Greater data security thanks to n FOC-typical better transmission characteristics n Greater possible transmission lengths of several 100 m n Greater possible data volumes thanks to lower attenuation values n Maximum EMC protection for the data transmitted n Future-proof installation (no cable replacement with new bus systems) 2. Greater mechanical protection through n The FOC designed for permanent mechanical movement n The igus-typical highly abrasion-proof and chemical resistant sheathing materials n The special Chainflex design concept (tested at 30 million cycles without a significant increase in attenuation) 3. Future-oriented cost reduction through n Bus-independent bus cable wiring n Longer service life in E-Chains n Extendable without transmission limits

Test data Page 4.36

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.157

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Chainflex

CFLK
PUR 12,5 x d

PUR Fibre optic cable (FOC) Chainflex CFLK


G POF fibres for high load requirements and interference-free transmission G PUR outer jacket G oil-resistant and coolant-resistant

Temperature range moved Temperature range fixed v max.


Polymer fibres (POF)

-20 C to +70 C, minimum bending radius 12,5 x d -25 C to +70 C, minimum bending radius 7,5 x d 10 m/s, 5 m/s 20 m/s2 Freely suspended and gliding travel distances up to 15 m, Class 1 Medium Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. 980/1000 m fibre with PE isolation. POF fibre with stranded high-tensile plastic reinforcement. Black core. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Red lilac (similar to RAL 4001)

unsupported/gliding a max. Travel distance UV-resistant Oil Silicon-free Halogen-free Fibre optic cable

Extruded inner jacket

Glass-fibre yarn wrap

Core stranding Core identification Outer jacket


Highly abrasionresistant PUR jacket blend

CE Lead free

Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

Class 5.1.3

Typical application area


n for high load requirements n maximum EMC protection n almost unlimited resistance to oil n preferably indoor applications n especially for freely suspended and gliding travel distances up to 15 m n wood/stone processing, packaging industry, supply system, handling, adjusting equipment
Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.158

Price index

Class 5.1.3
Delivery program Part No. CFLK.L1.01 1 Number of fibres Fibre diameter approx. [m] 980/1000 External diameter approx. [mm] 6,0 25 Weight [kg/km]

CFLK
PUR 12,5 x d

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Delivery program Part No. CFLK.L1.01

Bandwidth with 650 nm [MHz x km] 40

Attenuation with 650 nm [dB/km] 200

Colour code black

Delivery time 24h or today*


* Delivery time means time until shipping of goods

Woodworkingmachines with E-Chains and Chainflex cables

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFLK (for up to 10 cuts of the same type)

4.159

Tel. +49-2203-96 49-0

Please use www.chainflex.eu/en/CFLK for your online order.

Fax +49-2203-96 49-222

Order example: CFLK.L1.01 in your desired length (0,5 m steps) CFLK Chainflex series .L1 Type of fibres .01 Number of cores

Fibre optic cable

CFLG.2H
PUR 12,5 x d

PUR Fibre optic cable (FOC) Chainflex CFLG.2H


G for high load requirements G PUR outer jacket G metal-free G oil-resistant and coolant-resistant G UV-resistant

FOC-fibres

Plastic covered special fibre

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance UV-resistant Oil Offshore Silicon-free

-20 C to +60 C, minimum bending radius 12,5 x d -25 C to +60 C, minimum bending radius 7,5 x d 10 m/s, 6 m/s 20 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 High Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3 MUD-resistant following NEK 606 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). 50/125 m, 62,5/125 m, 200/230 m fibres in gel-filled hollow cores. Hollow cores with integrated FOC-fibres stranded with two strain relief elements. Cores black with white numerals. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour:Jet black (similar to RAL 9005) Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

Gel-filled, armored hollow core

Armored hollow cores with optimized pitch length stranded around a strain relief element

Fibre optic cable Core stranding Core identification Outer jacket

Gusset-filled extruded PUR mixture

CE Lead free

Typical application area


n for high load requirements

Class 6.3.3

n maximum EMC protection, with high transmission qualities in terms of glass-specific requirements n almost unlimited resistance to oil n indoor and outdoor applications n only for freely suspended and gliding travel distances up to 100 m n Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, cranes, refrigerating sector

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.160

Price index

Class 6.3.3
Delivery program Part No. CFLG.2HG.MF.62,5/125 CFLG.2HG.MF.50/125 CFLG.2HS.MF.200/230 2 2 2 Number of fibres Fibre diameter 62,5/125 50/125 200/230 External diameter 9,0 9,0 9,0 Weight [kg/km] 85 85 85 15,42 14,72 21,10 approx. [m] approx. [mm]

CFLG.2H
PUR 12,5 x d

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Delivery program Part No. CFLG.2HG.MF.62,5/125 CFLG.2HG.MF.50/125 CFLG.2HS.MF.200/230

Bandwidth

Attenuation Bandwidth

Attenuation Colour code

with 850 nm with 850 nm with 1300 nm with 1300 nm [MHz x km] [dB/km] 160 - 200 200 - 600 20 3,2 2,5 - 3,5 6,0 [MHz x km] [dB/km] 200 - 500 600 - 1200 0,9 0,7 - 1,5 black with white numbers black with white numbers black with white numbers

Order example: CFLG.2HG.MF.62,5/125 in your desired length (0,5 m steps) CFLG.2H Chainflex series .MF Metal-free .62,5/125 Type of fibres

Please use www.chainflex.eu/en/CFLG2HG for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Test data Page 4.36

Metal-free fibre optic cables for fast handling applications. E-Chain: System E2/000

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFLG2HG (for up to 10 cuts of the same type)

4.161

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Fibre optic cable

NEW in this catalog.


CFLG.LB
TPE 5xd

TPE Fibre optic cable (FOC) Chainflex CFLG.LB


G Gradient glass-fiber cable for maximum load requirements G TPE outer jacket G metal-free G oil-resistant G low-temperature-flexible up to -40 C G UV-resistant
Temperature range moved Temperature range -40 C to +60 C, minimum bending radius 5 x d 10 m/s, 6 m/s 20 m/s2 Freely suspended and gliding travel distances up to 100 m and more, Class 3 High Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Silicon-free Fibre optic cable Core stranding Core identification Overall shield Outer jacket Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). 50/125 m, 62.5/125 m special fixed wire elements with aramide strain relief. FOC cores stranded with high-tensile aramide dampers with especially short pitch length. Cores blue with white numerals. Extremely bending-resistant aramid braid for torsion protection. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) CE Lead free Following 2006/95/EG Following EC (RoHS) 2002/95/EC. fixed v max. unsupported/gliding a max. Travel distance UV-resistant Oil -40 C to +60 C, minimum bending radius 5 x d

FOC cores with hightensile aramide fibres

Reinforced optical fibres twisted with an optimized pitch

Aramid braid for torsion protection

Pressure extruded, halogen-free TPE blend

Typical application area

Class 7.3.4

n for maximum load requirements at 5 x d n Maximum EMC protection, with high transmission qualities in terms of glass-specific requirements n almost unlimited resistance to oil, also with bio-oils n Indoor and outdoor applications n especially for freely suspended and gliding travel distances up to 100 m and more n Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, semiconductor insertion, refrigerating sector
Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.162

Price index

Class 7.3.4
Delivery program Part No. CFLG.2LB.62,5/125 CFLG.2LB.50/125 2 2 Number of fibres Fibre diameter 62,5/125 50/125 External diameter 8,5 8,5 Weight [kg/km] 47 47 approx. [m] approx. [mm]

CFLG.LB
TPE 5xd

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Delivery program Part No. CFLG.2LB.62,5/125 CFLG.2LB.50/125

Bandwidth

Attenuation Bandwidth

Attenuation Colour code

with 850 nm with 850 nm with 1300 nm with 1300 nm [MHz x km] [dB/km] 160 - 200 200 - 600 3,2 2,5 - 3,5 [MHz x km] [dB/km] 200 - 500 600 - 1200 0,9 0,7 - 1,5 blue with white numbers blue with white numbers

Order example: CFLG.2LB.50/125 in your desired length (0,5 m steps) CFLG.2LB Chainflex series .50/125 Type of fibres

Please use www.chainflex.eu/en/CFLG2LB for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFLGLB (for up to 10 cuts of the same type) 4.163

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Fibre optic cable

CFLG. G
TPE 15 x d

TPE Fibre optic cable (FOC) Chainflex CFLG. G


G Gradient glass-fiber cable for maximum load requirements G TPE outer jacket G halogen-free G low-temperature-flexible up to -40 C G hydrolysis-resistant and microbe-resistant

Gradient fibres

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance UV-resistant Oil
Stranded GRP rods

-40 C to +60 C, minimum bending radius 15 x d -40 C to +60 C, minimum bending radius 8.5 x d 10 m/s, 6 m/s 20 m/s2 Freely suspended and gliding travel distances up to 500 m and more, Class 4 High Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992).

Gel-filled fibre sheath

Silicon-free

Halogen-free Fibre optic cable Core stranding Core identification


Highly abrasionresistant PUR blend with integrated torsion protection braid

Following EN 50267-2-1. 50/125 m, 62.5/125 m fibres in gel-filled hollow cores. Stranded GRP rods with integrated torsion protection braid in the outer jacket over gel-filled fiber sheath.. Schedule delivery program Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005)

Outer jacket

CE Lead free

Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

Class 7.4.4

Typical application area


n for maximum load requirements n maximum EMC protection, with high transmission qualities in terms of glass-specific requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications n only for freely suspended and gliding travel distances up to 500 m and more
Image exemplary.

n outdoor ship to shore, crane applications, conveyer technology

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.164

Price index

Class 7.4.4
Delivery program Part No. CFLG.6G.62,5/125.TC CFLG.12G.62,5/125.TC CFLG.6G.50/125.TC CFLG.12G.50/125.TC 6 12 6 12 Number of fibres Fibre diameter 62,5/125 62,5/125 50/125 50/125 External diameter 11,5 11,5 11,5 11,5 Weight [kg/km] 110 110 110 110 approx. [m] approx. [mm]

CFLG. G
TPE 15 x d

Other number of fibers upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Delivery program Part No. CFLG.6G.62,5/125.TC CFLG.12G.62,5/125.TC

Bandwidth

Attenuation Bandwidth

Attenuation Colour code

with 850 nm with 850 nm with 1300 nm with 1300 nm [MHz x km] [dB/km] 160 - 200 160 - 200 3,2 3,2 [MHz x km] [dB/km] 200 - 500 200 - 500 0,9 0,9 ecru, yellow, green, red, violet, blue ecru, yellow, green, red, violet, blue, lightblue, gray, brown, black, orange, pink

CFLG.6G.50/125.TC CFLG.12G.50/125.TC

200 - 600 200 - 600

2,5 - 3,5 2,5 - 3,5

600 - 1200 600 - 1200

0,7 - 1,5 0,7 - 1,5

ecru, yellow, green, red, violet, blue ecru, yellow, green, red, violet, blue, lightblue, gray, brown, black, orange, pink

Order example: CFLG.6G.62,5/125.TC in your desired length (0,5 m steps) CFLG.G Chainflex series .6G Number of cores .62,5/125 Type of fibres .TC Special identification

Please use www.chainflex.eu/en/CFLGGT for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Test data Page 4.40

igus fibre optic cables with 441 m travel. E-Chain: System E4/4

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFLGGT (for up to 10 cuts of the same type)

4.165

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Fibre optic cable

4.166

ervo cables

NEW* Chainflex cable

NEW*

CF27.D

CF21.UL

CF210.UL

Torsion resistant 10 10 10 10 v max. [m/s] unsupported 5 5 v max. [m/s] gliding 80 50 80 50 a max. [m/s2]

Chainflex types

* New in this catalog.

CF270.UL.D Servo cables


Jacket Shield PVC PVC PUR    7,5 10 10 -5/ +70 -5/ +70 -20/ +80   4.170 4.174  4.168 Page Minimum bending radius, moved [factor x d] Temperature moved from/to [C] Approvals and standards Oil-resistant

PUR  7,5 -20/ +80  4.178

4.167

NEW in this catalog.


CF210.UL
PVC 10 x d

PVC Servo cable Chainflex CF210.UL


G for medium load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Bending-resistant conductor

Temperature range moved Temperature range fixed v max. unsupported a max.


Extremely highly flexible braided-pair copper shield

-5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles. Minimum bending radius 10 x d -20 C to +70 C, minimum bending radius 5 x d 10 m/s 50 m/s2 Freely suspended travel distances, Class 1 Medium 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). Fine-wire stranded conductor in bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality, especially low-capacitance PE mixture. Energy conductor with signal pair elements stranded together with elements for high tensile stresses. Energy conductor: cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L-

Travel distance UV-resistant Nominal voltage

Energy conductor with signal pair elements stranded together with elements for high tensile stresses

Testing voltage Oil Flame-retardant

Bending-resistant braided copper shield

Silicon-free Conductor Core insulation

Pressure extruded, oil-resistent PVC blend

Core stranding Core identification

Class 4.1.2

1 signal pair: cores black with white numerals. 1. control core: 4 1. control core: 5 3. control core: 7 Element shield Intermediate jacket 2. control core: 5 2. control core: 6 4. control core: 8 2 signal pairs: cores black with white numerals.

Star-quad: yellow, black, red, white Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical.
Image exemplary.

Foil taping over the external layer.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.168

Price index

Class 4.1.2
Overall shield Outer jacket Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requireColour: Pastel orange (similar to RAL 2003) UL CEI CE Lead free Clean room Style 10989 and 2570, 1000 V, 80 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1 ments in Energy Chains (following DIN VDE 0281 Part 13).

CF210.UL
PVC 10 x d

Typical application area


n for medium load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended travel distances n Wood/stone processing, packaging industry, supply system, handling, adjusting equipment

Delivery program Part No. 1 control pair shielded CF210.UL.15.15.02.01 CF210.UL.25.15.02.01 CF210.UL.40.15.02.01 CF210.UL.60.15.02.01(1) 2 control pairs shielded CF210.UL.15.07.02.02 CF210.UL.25.15.02.02 CF210.UL.40.15.02.02 CF210.UL.60.15.02.02
(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 12,0 13,5 15,0 16,5 13,5 15,5 17,0 18,5

Copper index [kg/km] 149 203 272 364 169 260 330 425

Weight [kg/km]

(4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4,0+2x(2x1,5)C)C (4 G 6,0+2x(2x1,5)C)C

250 320 412 521 290 408 506 633

(1) Delivery time upon inquiry. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF210.25.15.02.01.UL in your desired length (0,5 m steps) CF210.UL Chainflex series .25 Code nominal cross section .15 Code nominal cross section signal pairs .02 Identification pairs .01 Number of pairs

Please use www.chainflex.eu/en/210.UL for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF210UL (for up to 10 cuts of the same type) 4.169

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Servo cable

CF21.UL
PVC 7,5 x d

PVC Servo cable Chainflex CF21.UL


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Highly flexible special conductor

Energy conductor with signal pair elements stranded around high-tensile center cord

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 -20 C to +70 C, minimum bending radius 4 x d -5 C to +70 C, minimum bending radius 7,5 x d

Extremely highly flexible braided-pair copper shield

UV-resistant Nominal voltage


Gusset-filled, pressure extruded

Medium 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2

Testing voltage Oil

Highly flexible braided copper shield

Flame-retardant Silicon-free

According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Energy conductor with signal pair elements stranded around high-tensile center cord. Energy conductor: cores black with white numerals, one core green/yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L1 control pair: cores black with white numerals. 1. control pair: 4 1. control pair: 5 3. control pair: 7 2. control pair: 5 2. control pair: 6 4. control pair: 8 2 control pairs: cores black with white numerals.

Pressure extruded, oil-proof PVC sheath blend

Conductor Core insulation Core stranding Core identification

Class 5.3.2

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.170

Price index

Class 5.3.2
Element shield Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Inner jacket Overall shield Outer jacket PVC mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0281 Part 13). Colour: Moss green (similar to RAL 6005) UL/CSA CEI CE Lead free Clean room Style 10492 and 2570, 1000 V, 80 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1

CF21.UL
PVC 7,5 x d

Typical application area


n for high load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF21UL (for up to 10 cuts of the same type)

4.171

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Servo cable

CF21.UL
PVC 7,5 x d

PVC Servo cable Chainflex CF21.UL


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Delivery program Part No. 1 control pair shielded CF21.07.05.02.01.UL CF21.15.10.02.01.UL CF21.15.15.02.01.UL CF21.25.10.02.01.UL(11) CF21.25.15.02.01.UL CF21.40.10.02.01.UL(11) CF21.40.15.02.01.UL CF21.60.10.02.01.UL(11) CF21.60.15.02.01.UL CF21.100.10.02.01.UL(1)/(11) CF21.100.15.02.01.UL CF21.160.15.02.01.UL CF21.350.15.02.01.UL CF21.07.03.02.02.UL CF21.10.07.02.02.UL CF21.15.07.02.02.UL CF21.25.15.02.02.UL CF21.40.15.02.02.UL CF21.60.15.02.02.UL
Image exemplary.
(1) (11)

Number of cores and conductor nominal cross section [mm2] (4 G 0,75+(2x0,5)C)C (4 G 1,5+(2x1,0)C)C (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,0)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,0)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,0)C)C (4 G 6,0+(2x1,5)C)C (4 G 10+(2x1,0)C)C (4 G 10+(2x1,5)C)C (4 G 16+(2x1,5)C)C (4 G 25+(2x1,5)C)C (4 G 35+(2x1,5)C)C (4 G 0,75+2x(2x0,34)C)C (4 G 1,0+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4,0+2x(2x1,5)C)C (4 G 6,0+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 16+2x(2x1,5)C)C (4 G 25+2x(2x1,5)C)C (4 G 35+2x(2x1,5)C)C

External diameter approx. [mm] 11,0 12,5 13,0 13,5 14,0 15,5 16,0 18,0 18,5 22,0 22,5 24,5 29,5 33,0 12,5 13,5 14,5 17,5 18,5 20,5 24,0 27,0 31,0 34,0

Copper index [kg/km] 95 125 140 177 182 232 241 327 357 530 540 716 1056 1557 113 146 175 265 304 397 560 790 1140 1597

Weight [kg/km]

172 250 280 300 312 372 390 495 605 786 925 1165 1466 2090 210 266 310 370 435 697 1025 1270 1910 2175

7,27 8,42 8,42 9,29 9,29 11,22 11,22 13,54 13,54 21,44 21,44 25,66 36,46 45,98 7,93 9,34 9,56 11,27 13,87 16,28 22,72 29,52 39,84 48,83

CF21.250.15.02.01.UL(1)
(1)

2 control pairs shielded

CF21.100.15.02.02.UL CF21.160.15.02.02.UL CF21.250.15.02.02.UL CF21.350.15.02.02.UL

(1) Delivery time upon inquiry (11) Phase-out model Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Class 5.3.2

Order example: CF21.15.10.02.01.UL in your desired length (0,5 m steps) CF21.UL Chainflex series .15 Code nominal cross section .10 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs

Please use www.chainflex.eu/en/CF21UL for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

... no minimum order quantity


4.172
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 5.3.2

CF21.UL
PVC 7,5 x d

Chainflex CF21.UL: cables for energy supply systems in spinneret production. E-Chain: Series E2/000

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF21UL (for up to 10 cuts of the same type)

4.173

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Servo cable

NEW in this catalog.


CF270.UL.D
PUR 10 x d

PUR Servo cable Chainflex CF270.UL.D


G for medium load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant G PVC-free/halogen-free
Temperature range moved Temperature range fixed v max. 10 m/s 50 m/s2 Freely suspended travel distances, Class 1 Medium 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3. MUD-resistant following NEK 606. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). Halogen-free Conductor Core insulation Core stranding Following EN 50267-2-1. Fine-wire stranded conductor in bending-resistant version consisting of bare copper wires (following EN 60228) Mechanically high-quality, especially low-capacitance TPE mixture. Energy conductor with signal pair elements stranded together with elements for high tensile stresses. unsupported a max. Travel distance UV-resistant -40 C to +80 C, minimum bending radius 5 x d -20 C to +80 C, minimum bending radius 10 x d

Bending-resistant conductor

Extremely highly flexible braided-pair copper shield

Energy conductor with signal pair elements stranded together with elements for high tensile stresses

Nominal voltage Testing voltage Oil Offshore Flame-retardant Silicon-free

Bending-resistant braided copper shield

Pressure extruded PUR blend

Class 4.1.3

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.174

Price index

Class 4.1.3
Core identification Energy conductor: cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 3. core: W / L3 / D / L1 signal pair: cores black with white numerals. 1. control core: 4 1. control core: 5 3. control core: 7 1. control core: 1 3. control core: 3 Star-quad: yellow, black, red, white Element shield Intermediate jacket Overall shield Outer jacket Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Foil taping over the external layer. Bending-resistant, tinned braided copper shield. Coverage approx. 55% linear, approx. 80% optical. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Pastel orange (similar to RAL 2003) UL/CSA CEI CE DESINA Lead free Clean room Style 10989 and 21223, 1000 V, 80 C Following CEI 20-35 Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC. According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1 2. control core: 5 2. control core: 6 4. control core: 8 2. control core: 2 2 signal pairs: cores black with white numerals. 2. core: V / L2

CF270.UL.D
PUR 10 x d

3 control pairs shielded: cores black with white numerals.

Typical application area


n for medium load requirements n almost unlimited resistance to oil n indoor and outdoor applications without direct sun radiation n especially for freely suspended travel distances n Machining units/machine tools, low temperature applications

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF270ULD (for up to 10 cuts of the same type) 4.175

Fax 0 22 03-96 49-222

Tel. 0 22 03-96 49-0

Servo cable

NEW in this catalog.


CF270.UL.D
PUR 10 x d

PUR Servo cable Chainflex CF270.UL.D


G for medium load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant G PVC-free/halogen-free
Delivery program Part No. Number of cores and conductor nominal cross section [mm2] External diameter approx. [mm] Copper index [kg/km] Weight [kg/km]

1 control pair shielded CF270.UL.15.15.02.01.D CF270.UL.25.15.02.01.D CF270.UL.40.15.02.01.D CF270.UL.60.15.02.01.D CF270.UL.160.15.02.01.D 2 control pairs shielded CF270.UL.07.03.02.02.D CF270.UL.10.07.02.02.D CF270.UL.15.07.02.02.D CF270.UL.25.15.02.02.D CF270.UL.40.15.02.02.D CF270.UL.60.15.02.02.D(1) CF270.UL.100.15.02.02.D CF270.UL.250.15.02.02.D 3 control pairs shielded CF270.UL.15.10.03.01.D(9)
Image exemplary.

(4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,5)C)C (4 G 16,0+(2x1,5)C)C (4 G 0,75+2x(2x0,34)C)C (4 G 1,0+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4,0+2x(2x1,5)C)C (4 G 6,0+2x(2x1,5)C)C (4 G 10,0+2x(2x1,5)C)C (4 G 25,0+2x(2x1,5)C)C

12,0 13,5 15,0 16,5 20,5 24,0 11,5 13,0 13,5 15,5 17,0 18,5 22,0 26,0 28,0 35,0 14,0 14,0 16,5 9,0 11,0 12,5 14,5 18,0 21,5 25,5 33,0

149 203 272 364 582 855 107 143 169 260 330 425 632 901 1365 1804 160 203 350 82 141 211 306 496 782 1197 1695

246 317 408 521 841 1225 197 251 290 408 506 633 940 1315 1847 2516 288 327 512 147 224 309 434 698 1052 1572 2312

CF270.UL.100.15.02.01.D(1) (4 G 10,0+(2x1,5)C)C

CF270.UL.160.15.02.02.D(1) (4 G 16,0+2x(2x1,5)C)C CF270.UL.350.15.02.02.D(1) (4 G 35,0+2x(2x1,5)C)C (4 G 1,5+(3x1,0)C)C (4 G 2,5+(3x1,0)C)C (4 G 6,0+(4x0,5)C)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)c (4 G 25,0)C (4 G 35,0)C

CF270.UL.25.10.03.01.D 1 Star-quad shielded CF270.UL.60.05.04.D Without signal pair CF270.UL.15.04.D CF270.UL.25.04.D CF270.UL.40.04.D CF270.UL.60.04.D

(10)

Class 4.1.3

CF270.UL.100.04.D CF270.UL.160.04.D CF270.UL.250.04.D(1) CF270.UL.350.04.D(1)

(1) Delivery time upon inquiry 9) Core/core: 50 pF/m, core/shield: 95 pF/m 10) Core/core: 70 pF/m, core/shield: 115 pF/m Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. x = without earth core G = with green-yellow earth core

... no minimum order quantity


4.176 eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 4.1.3
Order example: CF270.UL.25.15.02.01.D in your desired length (0,5 m steps) CF270.UL.D Chainflex series .25 Code nominal cross section .15 Code nominal cross section signal pairs .02 Identification pairs .01 Number of pairs

CF270.UL.D
PUR 10 x d

Please use www.chainflex.eu/en/CF270ULD for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF270ULD (for up to 10 cuts of the same type) 4.177

Fax 0 22 03-96 49-222

Tel. 0 22 03-96 49-0

Servo cable

CF27.D
PUR 7,5 x d

PUR Servo cable Chainflex CF27.D


G for maximum load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant G PVC-free/halogen-free
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 UV-resistant Medium 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3 Offshore Flame-retardant Silicon-free MUD-resistant following NEK 606 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Halogen-free Conductor Following EN 50267-2-1. Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Core insulation Core stranding Mechanically high-quality, especially low-capacitance TPE mixture. Energy conductor with signal pair elements stranded around high-tensile center cord. -40 C to +80 C, minimum bending radius 4 x d -20 C to +80 C, minimum bending radius 7,5 x d

Highly flexible special conductor

Energy conductor with signal pair elements stranded around high-tensile center cord

Extremely highly flexible braided-pair copper shield

Gusset-filled extruded

Nominal voltage Testing voltage

Highly flexible braided copper shield

Oil

Pressure extruded, halogen-free PUR blend

Class 6.3.3

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.178

Price index

Class 6.3.3
Core identification Energy conductor: cores black with white numerals, one core green/yellow. 1. core: U / L1 / C / L+ 3. core: W / L3 / D / L1 control pair: cores black with white numerals. 1. control pair: 4 1. control pair: 5 3. control pair: 7 2. control pair: 5 2. control pair: 6 4. control pair: 8 2 control pairs: cores black with white numerals. 2. core: V / L2

CF27.D
PUR 7,5 x d

Star-quad: yellow, black, red, white Element shield Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Inner jacket Overall shield Outer jacket PUR mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Pastel orange (similar to RAL 2003) UL/CSA CEI CE DESINA Lead free Clean room Style 10492 and 20234, 1000 V, 80 C Following CEI 20-35 Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC. According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

Typical application area


n for maximum load requirements n almost unlimited resistance to oil n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF27D (for up to 10 cuts of the same type)

4.179

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Servo cable

CF27.D
PUR 7,5 x d

PUR Servo cable Chainflex CF27.D


G for maximum load requirements G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant G PVC-free/halogen-free
Delivery program Part No. 1 control pair shielded CF27.07.05.02.01.D CF27.15.10.02.01.D CF27.15.15.02.01.D CF27.25.10.02.01.D(11) CF27.25.15.02.01.D CF27.40.10.02.01.D(11) CF27.40.15.02.01.D CF27.60.10.02.01.D(11) CF27.60.15.02.01.D CF27.100.10.02.01.D(11) CF27.100.15.02.01.D CF27.160.10.02.01.D CF27.160.15.02.01.D CF27.250.15.02.01.D CF27.350.15.02.01.D 2 control pairs shielded CF27.07.03.02.02.D CF27.10.07.02.02.D CF27.15.07.02.02.D (4 G 0,75+2x(2x0,34)C)C (4 G 1,0+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4,0+2x(2x1,5)C)C (4 G 6,0+2x(2x1,5)C)C (4 G 10,0+2x(2x1,5)C)C (4 G 16,0+2x(2x1,5)C)C (4 G 25,0+2x(2x1,5)C)C
(1) (11) (11)

Number of cores and conductor nominal cross section [mm2] (4 G 0,75+(2x0,5)C)C (4 G 1,5+(2x1,0)C)C (4 G 1,5+(2x1,5)C)C (4 G 2,5+(2x1,0)C)C (4 G 2,5+(2x1,5)C)C (4 G 4,0+(2x1,0)C)C (4 G 4,0+(2x1,5)C)C (4 G 6,0+(2x1,0)C)C (4 G 6,0+(2x1,5)C)C (4 G 10,0+(2x1,0)C)C (4 G 10,0+(2x1,5)C)C (4 G 16,0+(2x1,0)C)C (4 G 16,0+(2x1,5)C)C (4 G 25,0+(2x1,5)C)C (4 G 35,0+(2x1,5)C)C

External diameter approx. [mm] 11,5 12,5 12,5 13,5 14,0 16,0 16,0 17,5 17,5 20,5 21,5 23,0 24,5 28,5 32,5 12,5 13,5 14,5 16,5 18,0 19,5 23,5 26,0 30,0 33,5 14,5 15,0 17,0 18,0

Copper index [kg/km] 95 125 140 177 182 232 241 327 357 530 540 700 716 1056 1553 102 143 175 265 303 397 560 790 1140 1597 142 199 256 371

Weight [kg/km]

171 220 260 286 300 356 375 481 580 740 900 1023 1150 1435 2079 195 251 295 349 405 643 1000 1250 1890 2150 310 325 480 550

Image exemplary.

CF27.25.15.02.02.D CF27.40.15.02.02.D CF27.60.15.02.02.D CF27.100.15.02.02.D CF27.160.15.02.02.D CF27.250.15.02.02.D CF27.350.15.02.02.D 1 star quad shielded

(4 G 35,0+2x(2x1,5)C)C (4 G 1,5+(4x0,5)C)C (4 G 2,5+(4x0,5)C)C (4 G 4,0+(4x0,5)C)C (4 G 6,0+(4x0,5)C)C

Class 6.3.3

CF27.15.05.04.D CF27.25.05.04.D CF27.40.05.04.D CF27.60.05.04.D

(1) Delivery time upon inquiry (11) Phase-out model Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity


4.180
eplan download, configurator, PDF catalogues, lifetime ...

Price index

Class 6.3.3
Delivery program Part No. Without control pair CF27.07.04.D(1) CF27.10.04.D(1) CF27.15.04.D CF27.25.04.D CF27,500.04.D (4 G 0,75)C (4 G 1,0)C (4 G 1,5)C (4 G 2,5)C (4 G 50,0)C 9,5 10,0 10,5 12,0 37,5 52 62 86 140 2230 113 126 160 260 3200 Number of cores and conductor nominal cross section [mm ]
2

CF27.D
PUR 7,5 x d External diameter approx. [mm] Copper index [kg/km] Weight [kg/km]

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery time 24h or today*


* Delivery time means time until shipping of goods

Modular design, easy to retrofit: igus E4 energy supply system and Chainflex cables.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF27D (for up to 10 cuts of the same type)

4.181

Tel. +49-2203-96 49-0

Please use www.chainflex.eu/en/CF27D for your online order.

Fax +49-2203-96 49-222

Order example: CF27.15.10.02.01.D in your desired length (0,5 m steps) CF27 Chainflex series .15 Code nominal cross section .10 Code nominal cross section signalpairs .02 Identification pairs .01 Number of pairs

Servo cable

4.182

ower cable

Minimum bending radius, moved [factor x d]

Torsion resistant

Chainflex types
Approvals and standards Temperature moved from/to [C] Oil-resistant Chainflex cable Jacket Shield

a max. [m/s2]

v max. [m/s] unsupported

v max. [m/s] gliding

Power cables CF30 CF31 CF34.UL.D CF35.UL CF37.D CF38 CF300.UL.D CFPE CF310.UL CF330.D CF340
NEW* PVC PVC TPE TPE TPE TPE TPE TPE TPE TPE TPE      7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 7,5 -5/ +70 -5/ +70 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90 -35/ +90                  10 10 10 10 10 10 10 10 10 10 10 5 5 6 6 6 6 6 6 6 6 6 80 80 80 80 80 80 100 100 100 100 100 4.184 4.186 4.188 4.190 4.192 4.194 4.196 4.198 4.200 4.202 4.204

CF FLAT CF BRAID CF BRAID.C CF CRANE

TPE TPE TPE igupren  

5 7,5 7,5 10

-35/ +90 -35/ +70 -35/ +70 -20/ +80

   

10 10 10 10

6 6 6 6

100 80 80 50

4.206 4.208 4.208 4.210

Pneumatic hoses CF AIR CF Clean AIR


PU PE 10 10 -25/ +80 -25/ +60   10 10 6 6 50 50 4.212 4.214

Page

* New in this catalog.

4.183

CF30
PVC 7,5 x d

PVC Power cable Chainflex CF30


G for high load requirements G PVC outer jacket G oil-resistant G flame-retardant

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion

-5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles. Minimum bending radius 7,5 x d. -20 C to +70 C, minimum bending radius 4 x d 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 90 , with 1 m cable length

Highly flexible special conductor

UV-resistant Nominal voltage


Energy conductor stranded around high-tensile center cord

Medium 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). < 10 mm2: Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: cores black with white numerals, one core green/yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0281 Part 13). Colour: Jet black (similar to RAL 9005) Style 10492 and 2570, 1000 V, 80 C

Testing voltage Oil Flame-retardant Silicon-free

Gusset-filled extruded, oil-resistant PVC mixture

Conductor

Core insulation Core stranding Core identification

Class 5.3.2

Outer jacket

UL/CSA
Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.184

Price index

Class 5.3.2
CEI CE DESINA Lead free Clean room Following CEI 20-35 Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1

CF30
PVC 7,5 x d

Typical application area


n for high load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

Delivery program Part No. CF30.15.04 CF30.25.04 CF30.25.05 CF30.40.04 CF30.40.05 CF30.60.04 CF30.60.05 CF30.100.04 CF30.100.05 CF30.160.04 CF30.160.05 CF30.250.04 CF30.350.04 CF30.500.04

Number of cores and conductor nominal cross section [mm2] 4 G 1,5 4 G 2,5 5 G 2,5 4 G 4,0 5 G 4,0 4 G 6,0 5 G 6,0 4 G 10,0 5 G 10,0 4 G 16,0 5 G 16,0 4 G 25,0 4 G 35,0 4 G 50,0

External diameter approx. [mm] 8,5 10,5 11,5 12,0 13,0 14,0 15,0 18,0 20,0 21,0 24,0 26,0 29,0 35,0

Copper index [kg/km] 58 96 125 158 198 239 290 411 517 639 800 1020 1420 1990

Weight [kg/km] 105 165 199 242 295 351 417 581 731 904 1132 1425 1810 2675

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF30.15.04 in your desired length (0,5 m steps) CF30 Chainflex series .15 Code nominal cross section .04 Number of cores

Please use www.chainflex.eu/en/CF30 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF30 (for up to 10 cuts of the same type)

4.185

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF31
PVC 7,5 x d

PVC Power cable Chainflex CF31


G for high load requirements G PVC outer jacket G shielded G oil-resistant G flame-retardant

Highly flexible special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance UV-resistant Nominal voltage Testing voltage
Gusset-filled extruded

-5 C to +70 C following DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycles. Minimum bending radius 7,5 x d. -20 C to +70 C, minimum bending radius 4 x d 10 m/s, 5 m/s 80 m/s2 Freely suspended and gliding travel distances up to 100 m, Class 3 Medium 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-4-1), Class 2 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). < 10 mm2: Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: cores black with white numerals, one core green/yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N PVC mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion, oil-resistant mixture on the basis of PVC, adapted to suit the requirements in Energy Chains (following DIN VDE 0281 Part 13). Colour: Jet black (similar to RAL 9005) Style 10492 and 2570, 1000 V, 80 C

Energy conductor stranded around high-tensile center cord

Oil Flame-retardant

Highly flexible braided copper shield

Silicon-free Conductor

Pressure extruded, oil-proof PVC sheath blend

Core insulation Core stranding Core identification

Class 5.3.2

Inner jacket Overall shield Outer jacket

Image exemplary.

UL/CSA

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.186

Price index

Class 5.3.2
CEI CE Lead free Clean room Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 2. Outer jacket material complies with CF5.10.07, tested by IPA according to standard 14644-1

CF31
PVC 7,5 x d

Typical application area


n for high load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 100 m n storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes

Delivery program Part No. CF31.15.04 CF31.25.04 CF31.25.05 CF31.40.04 CF31.40.05 CF31.60.04 CF31.60.05 CF31.100.04 CF31.100.05 CF31.160.04 CF31.250.04 CF31.350.04 CF31.500.04 CF31.700.04(5)

Number of cores and conductor nominal cross section [mm2] (4 G 1,5)C (4 G 2,5)C (5 G 2,5)C (4 G 4,0)C (5 G 4,0)C (4 G 6,0)C (5 G 6,0)C (4 G 10,0)C (5 G 10,0)C (4 G 16,0)C (4 G 25,0)C (4 G 35,0)C (4 G 50,0)C (4 G 70,0)C

External diameter approx. [mm] 10,5 12,0 13,0 13,5 15,0 16,0 18,0 21,0 23,0 24,0 28,5 32,5 38,5 46,5

Copper index [kg/km] 85 129 158 197 253 299 362 501 624 748 1160 1570 2180 2965

Weight [kg/km] 171 237 280 326 397 475 577 772 934 1090 1643 2155 3125 4367

(5) Cable with PVC core insulation, UL-Style 10579 and 2570 , 600 V, 80 C Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF31.25.04 in your desired length (0,5 m steps) CF31 Chainflex series .25 Code nominal cross section .04 Number of cores

Please use www.chainflex.eu/en/CF31 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF31 (for up to 10 cuts of the same type)

4.187

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF34.UL.D
TPE 7,5 x d

TPE Power cable Chainflex CF34.UL.D


G for maximum load requirements G TPE outer jacket G oil- and bio-oil-resistant G flame-retardant G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion UV-resistant Nominal voltage Testing voltage Oil

-35 C to +90 C, minimum bending radius 7,5 x d -40 C to +90 C, minimum bending radius 4 x d 10 m/s, 6 m/s 80 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 90 , with 1 m cable length High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). < 10 mm2: Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: cores black with white numerals, one core green/yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) Style 10492 and 21184, 1000 V, 80 C Following CEI 20-35

Highly flexible special conductor

Energy conductor stranded around high-tensile center cord

Flame-retardant Silicon-free Conductor

Gusset-filled extruded TPE mixture

Core insulation Core stranding Core identification

Class 6.4.4

Outer jacket

UL/CSA CEI
Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.188

Price index

Class 6.4.4
CE DESINA Lead free Clean room Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC. According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

CF34.UL.D
TPE 7,5 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF34.UL.15.04.D CF34.UL.25.04.D CF34.UL.40.04.D CF34.UL.60.04.D CF34.UL.60.05.D CF34.UL.100.04.D CF34.UL.100.05.D CF34.UL.160.04.D CF34.UL.160.05.D CF34.UL.250.04.D CF34.UL.60.04.O.PE.D CF34.UL.100.04.O.PE.D CF34.UL.160.04.O.PE.D CF34.UL.500.03.O.PE.D

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 8,5 10,5 12,0 14,0 15,5 17,0 19,5 20,5 23,0 25,0 14,0 17,0 20,5 31,0

Copper index [kg/km] 58 96 158 239 285 411 517 633 800 994 239 411 633 1490

Weight [kg/km] 109 162 239 351 420 549 687 817 1072 1266 351 549 817 2028

4 G 1,5 4 G 2,5 4 G 4,0 4 G 6,0 5 G 6,0 4 G 10,0 5 G 10,0 4 G 16,0 5 G 16,0 4 G 25,0 4 x 6,0 4 x 10,0 4 x 16,0 3 x 50,0

Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF34.UL.160.04.D in your desired length (0,5 m steps) CF34.UL Chainflex series .160 Code nominal cross section .04 Number of cores

Please use www.chainflex.eu/en/CF34 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF34 (for up to 10 cuts of the same type)

4.189

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF35.UL
TPE 7,5 x d

TPE Power cable Chainflex CF35.UL


G for maximum load requirements G TPE outer jacket G shielded G oil- and bio-oil-resistant G flame-retardant G UV-resistant G hydrolysis-resistant and microbe-resistant

Highly flexible special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance UV-resistant Nominal voltage Testing voltage

-35 C to +90 C, minimum bending radius 7,5 x d -40 C to +90 C, minimum bending radius 4 x d 10 m/s, 6 m/s 80 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). < 10 mm2: Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: cores black with white numerals, one core green/yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) Style 10492 and 21184, 1000 V, 80 C

Energy conductor stranded around high-tensile center cord

Gusset-filled, pressure extruded TPE inner jacket

Oil Flame-retardant Silicon-free

Highly flexible braided copper shield

Conductor

Pressure extruded TPE blend

Core insulation Core stranding Core identification

Class 6.4.4

Inner jacket Overall shield Outer jacket

Image exemplary.

UL/CSA

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.190

Price index

Class 6.4.4
CEI CE Lead free Clean room Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CF35.UL
TPE 7,5 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF35.UL.05.04 CF35.UL.07.04 CF35.UL.15.04 CF35.UL.25.04 CF35.UL.40.04 CF35.UL.60.04 CF35.UL.100.04 CF35.UL.160.04 CF35.UL.250.04 CF35.UL.60.03.O.PE(1) CF35.UL.100.03.O.PE CF35.UL.160.03.O.PE CF35.UL.250.03.O.PE(1) CF35.UL.350.03.O.PE CF35.UL.500.03.O.PE
(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 8,0 8,5 9,5 11,5 13,5 16,0 19,5 23,0 27,5 14,5 17,5 21,0 24,5 28,5 33,5

Copper index [kg/km] 39 52 85 128 201 298 454 723 1160 231 356 553 884 1200 1660

Weight [kg/km] 81 104 149 207 326 450 682 1003 1524 367 568 789 1208 1675 2283

(4 G 0,5)C (4 G 0,75)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C (4 G 25,0)C (3 x 6,0)C (3 x 10,0)C (3 x 16,0)C (3 x 25,0)C (3 x 35,0)C (3 x 50,0)C

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF35.UL.15.04 in your desired length (0,5 m steps) CF35.UL Chainflex series .15 Code nominal cross section .04 Number of cores

Please use www.chainflex.eu/en/CF35 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF35 (for up to 10 cuts of the same type)

4.191

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF37.D
TPE 7,5 x d

TPE Power cable Chainflex CF37.D


G for maximum load requirements G TPE outer jacket G oil- and bio-oil-resistant G PVC-free/halogen-free G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion 10 m/s, 6 m/s 80 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 90 , with 1 m cable length -35 C to +90 C, minimum bending radius 7,5 x d -40 C to +90 C, minimum bending radius 4 x d

Highly flexible special conductor

UV-resistant Nominal voltage


Energy conductor stranded around high-tensile center cord

High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992).

Testing voltage Oil Silicon-free

Gusset-filled extruded TPE mixture

Halogen-free Conductor

Following EN 50267-2-1. < 10 mm2: stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). 10 mm2: conductor cable consisting of pre-leads (following EN 60228).

Core insulation

Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 3. core: W / L3 / D / L2. core: V / L2 4. core: 4 / N

Class 7.4.4

Core stranding Core identification

Outer jacket
Image exemplary.

Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005)

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.192

Price index

Class 7.4.4
CE DESINA Lead free Clean room Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

CF37.D
TPE 7,5 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF37.15.04.D CF37.25.04.D CF37.40.04.D(1) CF37.60.04.D CF37.60.05.D(1) CF37.100.04.D CF37.100.05.D(1) CF37.160.04.D CF37.160.05.D(1) CF37.250.04.D CF37.60.04.O.PE.D(1) CF37.100.04.O.PE.D(1) CF37.160.04.O.PE.D CF37,500.03.O.PE.D
(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 8,5 10,5 12,0 14,0 15,5 17,0 19,5 20,5 23,0 25,0 14,0 17,0 20,5 31,0

Copper index [kg/km] 58 96 158 239 285 411 517 633 800 994 239 411 633 1490

Weight [kg/km] 109 162 239 351 420 549 687 817 1072 1266 351 549 817 2028

4 G 1,5 4 G 2,5 4 G 4,0 4 G 6,0 5 G 6,0 4 G 10,0 5 G 10,0 4 G 16,0 5 G 16,0 4 G 25,0 4x6 4 x 10 4 x 16 3 x 50

(1) Delivery time upon inquiry Other types available on request. Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF37.250.04.D in your desired length (0,5 m steps) CF37.D Chainflex series .250 Code nominal cross section .04 Number of cores

Please use www.chainflex.eu/en/CF37 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF37 (for up to 10 cuts of the same type) 4.193

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF38
TPE 7,5 x d

TPE Power cable Chainflex CF38


G for maximum load requirements G TPE outer jacket G shielded G oil- and bio-oil-resistant G PVC-free/halogen-free G UV-resistant G hydrolysis-resistant and microbe-resistant

Highly flexible special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max.

-35 C to +90 C, minimum bending radius 7,5 x d -40 C to +90 C, minimum bending radius 4 x d 10 m/s, 6 m/s 80 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. < 10 mm2: stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). 10 mm2: conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality, especially low-capacitance TPE mixture. Cores stranded in short pitch lengths over a centre for high tensile stresses. Energy conductor: cores black with white numerals, one core green-yellow. 1. core: U / L1 / C / L+ 2. core: V / L2 3. core: W / L3 / D / L4. core: 4 / N TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005)

Energy conductor stranded around high-tensile center cord

Travel distance

UV-resistant Nominal voltage


Gusset-filled pressure extruded TPE inner jacket

Testing voltage Oil Silicon-free

Highly flexible braided copper shield

Halogen-free Conductor

Pressure extruded TPE blend

Core insulation Core stranding Core identification

Class 7.4.4

Inner jacket Overall shield Outer jacket


Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.194

Price index

Class 7.4.4
CE Lead free Clean room Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CF38
TPE 7,5 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF38.05.04(1) CF38.07.04 CF38.15.04 CF38.25.04(1) CF38.40.04 CF38.60.04(1) CF38.100.04 CF38.160.04 CF38.250.04 CF38.60.03.O.PE(1) CF38.100.03.O.PE CF38.250.03.O.PE CF38.500.03.O.PE
(1) (1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 8,0 8,5 9,5 11,5 13,5 16,0 19,5 23,0 27,5 14,5 17,5 21,0 24,5 28,5 33,5

Copper index [kg/km] 39 52 85 128 201 298 454 723 1160 231 356 553 884 1200 1660

Weight [kg/km] 81 104 149 207 326 450 682 1003 1524 367 568 789 1208 1675 2283

(4 G 0,5)C (4 G 0,75)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C (4 G 25,0)C (3 x 6,0)C (3 x 10,0)C (3 x 16,0)C (3 x 25,0)C (3 x 35,0)C (3 x 50,0)C

CF38.160.03.O.PE(1)
(1)

CF38.350.03.O.PE(1)
(1)

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF38.25.04 in your desired length (0,5 m steps) CF38 Chainflex series .25 Code nominal cross section .04 Number of cores

Please use www.chainflex.eu/en/CF38 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF38 (for up to 10 cuts of the same type) 4.195

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF300.UL.D
TPE 7,5 x d

TPE Power cable Chainflex CF300.UL.D


G for maximum load requirements G TPE outer jacket G oil- and bio-oil-resistant G flame-retardant G UV-resistant G hydrolysis-resistant and microbe-resistant

Highly flexible special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion

-35 C to +90 C, minimum bending radius 7,5 x d -40 C to +90 C, minimum bending radius 4 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 90 , with 1 m cable length

UV-resistant Nominal voltage Testing voltage Oil


Pressure extruded TPE blend

High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality TPE mixture. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) Following 2006/95/EG Style 10492 and 21184, 1000 V, 80 C Following CEI 20-35 Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

Flame-retardant Silicon-free Conductor


Pressure extruded TPE blend

Core insulation Outer jacket

Class 6.4.4

CE UL/CSA CEI Lead free Clean room

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.196

Price index

Class 6.4.4
Typical application area
n for maximum load requirements n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications Delivery program Part No. CF300.UL.40.01.D CF300.UL.60.01.D CF300.UL.100.01.D CF300.UL.160.01.D CF300.UL.250.01.D CF300.UL.350.01.D CF300.UL.500.01.D CF300.UL.700.01.D CF300.UL.950.01.D CF300.UL.1200.01.D CF300.UL.1500.01.D CF300.UL.1850.01.D Number of cores and conductor nominal cross section [mm2] 1x4,0 1x6,0 1x10,0 1x16,0 1x25,0 1x35,0 1x50,0 1x70,0 1x95,0 1x120,0 1x150,0 1x185,0 External diameter approx. [mm] 6,5 7,0 8,0 9,5 11,5 12,5 14,5 16,5 19,0 21,5 23,0 27,0 Copper index [kg/km] 38 56 96 151 239 333 479 623 848 1059 1318 1890 61 77 119 183 281 377 525 676 927 1145 1411 2014 NEW* Weight [kg/km] n almost unlimited resistance to oil, also with bio-oils

CF300.UL.D
TPE 7,5 x d

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Order example: CF300.UL.950.01.D in your desired length (0,5 m steps) CF300.UL.D Chainflex series .950 Code nominal cross section .01 Number of cores

Please use www.chainflex.eu/en/CF300 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

STS cranes in Antwerp with igus Energy Chain Systems for energy and data supplies to centenary and main trolley.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF300 (for up to 10 cuts of the same type)

4.197

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CFPE
TPE 7,5 x d

TPE Power cable Chainflex CFPE


G for maximum load requirements G TPE outer jacket G oil- and bio-oil-resistant G flame-retardant G UV-resistant G hydrolysis-resistant and microbe-resistant

Highly flexible special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion UV-resistant Nominal voltage Testing voltage Oil

-35 C to +90 C, minimum bending radius 7,5 x d -40 C to +90 C, minimum bending radius 4 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 90 , with 1 m cable length High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Conductor cable consisting of pre-leads (following EN 60228).

Pressure extruded TPE blend

Flame-retardant Silicon-free Conductor

Pressure extruded, flame-retard TPE blend

Core insulation Core identification Outer jacket

Mechanically high-quality TPE mixture. green-yellow Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) Style 10492 and 21184, 1000 V, 80 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

UL/CSA

Class 6.4.4

CEI CE Lead free Clean room


Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.198

Price index

Class 6.4.4
Typical application area
n for maximum load requirements n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications n almost unlimited resistance to oil, also with bio-oils

CFPE
TPE 7,5 x d

Delivery program Part No. CFPE.15.01 CFPE.25.01 CFPE.40.01 CFPE.60.01 CFPE.100.01 CFPE.160.01 CFPE.250.01 CFPE.350.01

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 5,0 5,5 6,0 7,5 8,0 9,5 11,5 13,0

Copper index [kg/km] 15 25 38 56 96 151 239 333

Weight [kg/km] 35 46 61 81 123 191 291 387

1 G 1,5 1 G 2,5 1 G 4,0 1 G 6,0 1 G 10,0 1 G 16,0 1 G 25,0 1 G 35,0

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CFPE.15.01 in your desired length (0,5 m steps) CFPE Chainflex series .15 Code nominal cross section .01 Number of cores

Please use www.chainflex.eu/en/CFPE for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Chainflex CFPE for machining units. E-Chain: Series E2 medium

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFPE (for up to 10 cuts of the same type)

4.199

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF310.UL
TPE 7,5 x d

TPE Power cable Chainflex CF310.UL


G for maximum load requirements G TPE outer jacket G shielded G oil- and bio-oil-resistant G flame-retardant G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance

Highly flexible special conductor

-35 C to +90 C, minimum bending radius 7,5 x d -40 C to +90 C, minimum bending radius 4 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Conductor cable consisting of pre-leads (following EN 60228).

UV-resistant Nominal voltage


Pressure extruded TPE blend

Testing voltage Oil

Highly flexible braided copper shield

Flame-retardant Silicon-free Conductor

Pressure extruded TPE blend

Core insulation Overall shield Outer jacket

Mechanically high-quality TPE mixture. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) Style 10492 and 21184, 1000 V, 80 C Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

Class 6.4.4

UL/CSA CEI CE Lead free

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.200

Price index

Class 6.4.4
Clean room According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CF310.UL
TPE 7,5 x d

n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Delivery program Part No. CF310.UL.40.01 CF310.UL.60.01 CF310.UL.100.01 CF310.UL.160.01 CF310.UL.250.01 CF310.UL.350.01 CF310.UL.500.01 CF310.UL.700.01 CF310.UL.950.01 CF310.UL.1200.01 CF310.UL.1500.01 CF310.UL.1850.01

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 6,5 7,5 8,5 10,0 11,5 13,5 15,0 17,5 20,5 22,0 24,0 28,0

Copper index [kg/km] 55 75 120 178 272 380 524 689 920 1140 1436 2020

Weight [kg/km] 74 97 144 210 314 423 568 748 997 1233 1549 2147

(1x4,0)C (1x6,0)C (1x10,0)C (1x16,0)C (1x25,0)C (1x35,0)C (1x50,0)C (1x70,0)C (1x95,0)C (1x120,0)C (1x150,0)C (1x185,0)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF310.UL.40.01 in your desired length (0,5 m steps) CF310.UL Chainflex series .40 Code nominal cross section .01 Number of cores

Please use www.chainflex.eu/en/CF310 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Chainflex CF310.UL for outdoor crane systems. E-Chain: Series E4/00

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF310 (for up to 10 cuts of the same type)

4.201

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

Typical application area

CF330.D
TPE 7,5 x d

TPE Power cable Chainflex CF330.D


G for maximum load requirements G TPE outer jacket G oil- and bio-oil-resistant G PVC-free/halogen-free G UV-resistant G hydrolysis-resistant and microbe-resistant

Highly flexible special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance Torsion UV-resistant Nominal voltage Testing voltage Oil Silicon-free 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 90 , with 1 m cable length High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Halogen-free Conductor Core insulation Outer jacket Following EN 50267-2-1. Conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality TPE mixture. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) -40 C to +90 C, minimum bending radius 4 x d -35 C to +90 C, minimum bending radius 7,5 x d

Pressure extruded TPE blend

Pressure extruded TPE blend

Class 7.4.4

CE DESINA Lead free Clean room


Image exemplary.

Following 2006/95/EG According to VDW, DESINA standardisation Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.202

Price index

Class 7.4.4
Typical application area
n for maximum load requirements n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications n almost unlimited resistance to oil, also with bio-oils

CF330.D
TPE 7,5 x d

Delivery program Part No. CF330.60.01.D CF330.100.01.D CF330.160.01.D CF330.250.01.D CF330.350.01.D CF330.500.01.D CF330.700.01.D CF330.950.01.D CF330.1200.01.D CF330.1500.01.D CF330.1850.01.D

Number of cores and conductor nominal cross section [mm2] 1x6,0 1x10,0 1x16,0 1x25,0 1x35,0 1x50,0 1x70,0 1x95,0 1x120,0 1x150,0 1x185,0

External diameter approx. [mm] 7,0 8,0 9,5 11,5 12,5 14,5 16,5 19,0 21,5 23,0 27,0

Copper index [kg/km] 56 96 151 239 333 479 623 848 1059 1318 1890

Weight [kg/km] 77 119 183 281 377 525 676 927 1145 1411 2014

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF330.160.01.D in your desired length (0,5 m steps) CF330.D Chainflex series .160 Code nominal cross section .01 Number of cores

Please use www.chainflex.eu/en/CF330 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF330 (for up to 10 cuts of the same type) 4.203

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF340
TPE 7,5 x d

TPE Power cable Chainflex CF340


G for maximum load requirements G TPE outer jacket G shielded G oil- and bio-oil-resistant G PVC-free/halogen-free G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance

Highly flexible special conductor

-35 C to +90 C, minimum bending radius 7,5 x d -40 C to +90 C, minimum bending radius 4 x d 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. Conductor cable consisting of pre-leads (following EN 60228). Mechanically high-quality TPE mixture. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

UV-resistant Nominal voltage


Pressure extruded TPE blend

Testing voltage Oil Silicon-free

Highly flexible braided copper shield

Halogen-free Conductor

Pressure extruded TPE blend

Core insulation Overall shield Outer jacket

Class 7.4.4

CE Lead free Clean room

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.204

Price index

Class 7.4.4
Typical application area
n for maximum load requirements n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications n almost unlimited resistance to oil, also with bio-oils

CF340
TPE 7,5 x d

Delivery program Part No. CF340.40.01 CF340.60.01


(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 6,5 7,5 8,5 10,0 11,5 13,5 15,0 17,5 20,5 22,0 24,0 28,0

Copper index [kg/km] 55 75 120 178 272 380 524 689 920 1140 1436 2020

Weight [kg/km] 74 97 144 210 314 423 568 748 997 1233 1549 2147

(1x4,0)C (1x6,0)C (1x10,0)C (1x16,0)C (1x25,0)C (1x35,0)C (1x50,0)C (1x70,0)C (1x95,0)C (1x120,0)C (1x150,0)C (1x185,0)C
(1)

CF340.100.01(1) CF340.160.01 CF340.250.01(1) CF340.350.01 CF340.500.01 CF340.700.01 CF340.950.01(1) CF340.1200.01 CF340.1500.01 CF340.1850.01

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CF340.100.01 in your desired length (0,5 m steps) CF340 Chainflex series .100 Code nominal cross section .01 Number of cores

Please use www.chainflex.eu/en/CF340 for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CF340 (for up to 10 cuts of the same type) 4.205

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

NEW in this catalog.


CF FLAT
TPE 5xd

TPE Power cable Chainflex CF FLAT


G for maximum load requirements G TPE outer jacket G oil-resistant G bio-oil-resistant G PVC-free/halogen-free G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance UV-resistant Nominal voltage Testing voltage Oil Silicon-free 10 m/s, 6 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4. High 600/1000 V (following DIN VDE 0250) 4000 V (following DIN VDE 0281-2) Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Halogen-free Conductor Core insulation Outer jacket Following EN 50267-2-1 Highly flexible braided special conductor Mechanically high-quality TPE mixture. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) CE Lead free Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1 -40 C to +100 C, minimum bending radius 4 x d -35 C to +100 C, minimum bending radius 5 x d

Highly flexible braided special conductor

Pressure extruded TPE blend

Pressure extruded TPE blend

Class 7.4.4

Clean room

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.206

Price index

Class 7.4.4
Typical application area
n for maximum load requirements n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, tight design space, small radii, machining units/machine tools, quick handling, clean room, semiconductor insertion, low-temperature applications n almost unlimited resistance to oil, also with bio-oils

CF FLAT
TPE 5xd

Delivery program Part No. CFFLAT.25.01 CFFLAT.40.01

Number of cores and External conductor nominal cross section [mm2] 1x2,5 1x4,0 diameter approx. [mm] 13,5 x 5,0 14,0 x 5,0

Copper index [kg/km] 30 46

Weight [kg/km] 71 109

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CFFLAT.25.01 in your desired length (0,5 m steps) CFFLAT Chainflex series .25 Code nominal cross section .01 Number of cores

Please use www.chainflex.eu/en/CFFLAT for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFFLAT (for up to 10 cuts of the same type) 4.207

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CFBRAID
TPE 7,5 x d

TPE Power cable Chainflex CF BRAID


G for maximum load requirements G TPE outer jacket G unshielded/shielded G oil- and bio-oil-resistant G flame-retardant G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max.

Highly flexible special conductor

-35 C to +70 C, minimum bending radius 7,5 x d -40 C to +70 C, minimum bending radius 4 x d 10 m/s, 6 m/s 80 m/s2 Freely suspended and gliding travel distances up to 400 m and more, Class 4 High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality TPE mixture (following DIN VDE 0207 Part 4). Cores braided together using a special technique. Cores black with white numerals, one core green-yellow. TPE mixture adapted to suit the requirements in Energy Chains (for shielded types). Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical (for shielded types). Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005)

Cores braided together using a special technique

Travel distance

UV-resistant Nominal voltage Testing voltage Oil


TPE Inner jacket

Flame-retardant
Highly flexible braided copper shield

Silicon-free Conductor Core insulation

Pressure extruded TPE blend

Core stranding Core identification Inner jacket

Class 6.4.4

Overall shield

Outer jacket

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.208

Price index

Class 6.4.4
CE Following 2006/95/EG CEI Lead free Clean room Following CEI 20-35 Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CFBRAID
TPE 7,5 x d

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, quick handling, in- and outdoor cranes, low-temperature applications

What is special about CF BRAID?


Due to their unique type of design and especially in the case of cross-sections 0,5 mm2 and long distances of travel with large numbers of cycles, cables with 7 cores have an increased tendency toward the formation of corkscrews. Due to the special design of the CF BRAID with 8 braided cores, corkscrews can be completely ruled out.

Delivery program Part No. CFBRAID.25.08 CFBRAID.25.08.C(8)

Number of cores and conductor nominal cross section [mm2] 8 G 2,5 (8 G 2,5)C

External diameter approx. [mm] 20,0 23,5

Copper index [kg/km] 192 320

Weight [kg/km] 398 625

(8) without Desina Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CFBRAID.25.08 in your desired length (0,5 m steps) CFBRAID Chainflex series .25 Code nominal cross section .08 Number of cores

Please use www.chainflex.eu/en/CFBRAID for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFBRAID (for up to 10 cuts of the same type)

4.209

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF CRANE
iguprene 10 x d

igupren Power cable Chainflex CF CRANE


G for maximum voltages and outputs G iguprene outer jacket G oil-resistant G flame-retardant

Highly flexible special conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Travel distance 10 m/s, 6 m/s 50 m/s2 Freely suspended and gliding travel distances up to 500 m and more, Class 4 -30 C to +80 C, minimum bending radius 7,5 x d -20 C to +80 C, minimum bending radius 10 x d

UV-resistant Nominal voltage


Extruded EPR insulation over conductive rubber

High 6/10 kV (following DIN VDE 0250), other voltages upon inquiry.

Testing voltage Oil

17 kV (following DIN VDE 0250, part 813). Oil-resistant (following EN 60811-2-1), Class 3 According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Highly flexible cable consisting of tinned copper wires (following VDE 0295). Inner and outer semiconducting layer made of conductive rubber. Insulating sheath made of high-quality, heat-resistant and ozone-proof ethylene propylene rubber (EPR).

Highly flexible overall copper shield

Flame-retardant Silicon-free Conductor Core insulation

Extruded, highly abrasionresistant iguprene jacket blend

Overall shield Outer jacket

Extremely bending-resistant, tinned copper shield. Coverage approx. 80% optical. Low-adhesion mixture on the basis of iguprene, especially abrasion-resistant and highly flexible, adapted to suit the requirements in Energy Chains (following DIN VDE 0207 Part 21). Colour: red

Class 6.4.3

CE Lead free
Image exemplary.

Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.210

Price index

Class 6.4.3
Typical application area
n for maximum load requirements n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 500 m and more n outdoor ship to shore, crane applications, conveyer technology n almost unlimited resistance to oil

CF CRANE
iguprene 10 x d

Delivery program Part No. CFCRANE1x25/16-6/10kV(1) CFCRANE1x35/16-6/10kV CFCRANE1x70/16-6/10kV


(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 27,0 29,0 30,0 32,0 34,0

Copper index [kg/km] 468 576 712 912 1145

Weight [kg/km] 940 1110 1350 1550 1820

(1 x 25/16)C (1 x 35/16)C (1 x 50/16)C (1 x 70/16)C (1 x 95/16)C

CFCRANE1x50/16-6/10kV(1)
(1)

CFCRANE1x95/16-6/10kV(1)

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CFCRANE1x25/16-6/10kV in your desired length (0,5 m steps) CFCRANE Chainflex series .1 x 25/16 Code nominal cross section -6/10 Nominal voltage

Please use www.chainflex.eu/en/CFCRANE for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Chainflex CFCRANE for 500 m and more of travel. E-Chain: igus Rol E-Chain

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFCRANE (for up to 10 cuts of the same type)

4.211

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Power cable

CF AIR
PU 10 x d

Pneumatic hose Chainflex CF AIR


G for maximum load requirements G PU hose G oil-resistant and coolant-resistant G abrasion-resistant G outside-toleranced G halogen-free

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Dimensions Operating pressure Vacuum Oil Halogen-free Material 10 m/s, 6 m/s 50 m/s2 Outside-toleranced 12 bar at 20 C -1 bar at 20 C Oil-resistant. Following EN 50267-2-1. Abrasion-resistant on the basis of Polyurethan adapted to suit the requirements in Energy Chains. Colour: blue Lead free Following EC (RoHS) 2002/95/EC. -40 C to +85 C, minimum bending radius 8 x d -20 C to +80 C, minimum bending radius 10 x d

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.212

Price index

CF AIR
PU 10 x d

Delivery program Part No. CA PU.A.04.0 CA PU.A.06.0 CA PU.A.08.0 CA PU.A.10.0 CA PU.A.12.0 CA PU.A.16.0

Max. package Internal length [km] 2,0 1,5 1,0 1,0 0,5 0,1 diameter approx. [mm] 2,7 4,0 5,7 7,0 8,0 11,0

Wall thickness 0,65 1,00 1,15 1,50 2,00 2,50

External diameter

Weight [g/m] 8 19 30 48 76 127

approx. [mm] approx. [mm] 4 6 8 10 12 16

Order example: CA PU.A.04.0 in your desired length (0,5 m steps) CA PU Chainflex series .A Code material .04 Code .0 Special identification

Please use www.chainflex.eu/en/CAPU for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

igus Chainflex CF AIR pneumatic hoses were tested over several million bending cycles in E-Chains. Their outstanding features include flexibility, high abrasion resistance and very good resistance to oil and coolants.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CAPU (for up to 10 cuts of the same type)

4.213

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Pneumatic hose

CF Clean AIR
PE 10 x d

Pneumatic hose Chainflex CF Clean AIR


G for maximum load requirements G PE hose G oil-resistant and coolant-resistant G highly abrasion-resistant G outside-toleranced G halogen-free
Temperature range moved Temperature range fixed v max. unsupported/gliding a max. Dimensions Operating pressure Vacuum Oil Halogen-free Material Lead free Clean room 10 m/s, 6 m/s 50 m/s2 Outside-toleranced 10 bar at 20 C -0.95 bar at 20 C Oil-resistant. Following EN 50267-2-1. Highly abrasion-resistant on the basis of Polyethylen adapted to suit the requirements in Energy Chains. Colour: white Following EC (RoHS) 2002/95/EC. According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1 -30 C to +65 C, minimum bending radius 8 x d -25 C to +60 C, minimum bending radius 10 x d

Typical application area


n for especially high abrasion resistance n clean room, semi-conductor industry, handling

Image exemplary.

igus material abrasion test

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.214

Price index

CF Clean AIR
PE 10 x d

Delivery program Part No. CA PE.A.04.0 CA PE.A.06.0 CA PE.A.08.0 CA PE.A.10.0 CA PE.A.12.0 CA PE.A.16.0

Max. package Internal length [km] 2,0 1,5 1,0 1,0 0,5 0,1 diameter approx. [mm] 2,7 4,0 5,7 7,0 8,0 11,0

Wall thickness 0,65 1,00 1,15 1,50 2,00 2,50

External diameter

Weight [g/m] 6 15 21 38 54 90

approx. [mm] approx. [mm] 4 6 8 10 12 16

Order example: CA PE.A.04.0 in your desired length (0,5 m steps) CA PE Chainflex series .A Code material .04 Code .0 Special identification

Please use www.chainflex.eu/en/CAPE for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

Comparison: abrasion of pneumatic hoses PUR, PE and PA in combination with igus E-Chains *

Abrasion in mm

PUR hose PE hose 10x 1,5 PA hose

Double strokes
* igus E-Chain with opening link 450.30

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CAPE (for up to 10 cuts of the same type) 4.215

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Pneumatic hose

wistable cables

obot

Minimum bending radius, moved [factor x d]

Torsion resistant

Chainflex Typen
Approvals and standards Temperature moved from/to [C] Oil-resistant Chainflex cable Jacket Shield

a max. [m/s2]

v max. [m/s] unsupported

v max. [m/s] gliding

Twistable cables Hybrid cable/Control cable


NEW*

CF ROBOT9 Bus cable


NEW*

PUR

10,0

-25/ +80

10

10

4.220

CF ROBOT8

PUR

10,0

-20/ +70

10

10

4.222

Measuring system cable


NEW*

CF ROBOT4 Fibre optic cable


NEW*

PUR

10,0

-25/ +80

10

10

4.224

CF ROBOT5

TPE

12,5

-20/ +60

10

10

4.226

Power cable/Servo cable


NEW*

CF ROBOT6
NEW*

PUR

10,0

-25/ +80

10

10

4.228

CF ROBOT7 CF ROBOT

PUR TPE

 

10,0 10,0

-25/ +80 -35/ +100

 

 

10 10

10 10

4.228 4.230

Page

* New in this catalog.

4.217

Info

Chainflex cables for robots


Ever more complex sequences of movements in industrial applications demand twistable and/or three-dimensional flexible cables with a long service life similar to the classic Chainflex cables for use in linear E-ChainSystems. Wires, stranded, shields and sheathing materials must compensate both major changes in bending load and changes in diameter due to torsional movements. For this purpose, different "soft" structural elements e.g. rayon fibres, PTFE elements or filling elements that absorb torsion forces are used in Chainflex ROBOT cables. Special demands are made on the braided shielding in torsion cables. Torsion-optimised shield structures are chosen that can carry out the necessary compensatory movements thanks to special PTFE gliding films. With twistable bus cables in particular, the transmission characteristics such as attenuation, cable capacity and signal quality must remain within very tight tolerance ranges over the whole service life. This is achieved through the use of particularly torsionoptimised insulating materials and mechanical attenuation elements with matching capacity values. The highly abrasion-resistant, halogen-free and flameresistant PUR sheathing mixture in motor, hybrid/control cables and bus cables protects the torsion-optimised stranded elements from possible damage. The highly abrasion-resistant, halogen-free TPE-sheath mixture matches the special requirements of the twistable FOC and individual wires, and also protects the stranded elements. Unlike cables for linear E-ChainSystems, the "mechanical stress" for these cables is in the combination of bending, torsion and centrifugal forces that cannot usually be determined by design in advance or during use by means of measurement. For this reason, and unlike the situation with linear EChain applications, a clear "yes/no" statement cannot be made about the possibility of using a certain cable in torsion applications. To enable evaluation to take place nevertheless, based on sensible and comparable test results, the igus "torsion test standard" was developed.

According to this standard, all Chainflex ROBOT cables of a Triflex R Energy Chain are twisted with a fixed-point distance of one metre and a torsion of +/- 180 at least 3 million times. In addition, a test is carried out on a test bench with a chain length of approx. 2500 mm with 270 torsion with an extreme load through centrifugal forces and heavy blows such as those that can occur with an industrial robot. All the non-shielded, gusset-filled extruded standard Chainflex control cables of the series CF5, CF77.UL.D and CF 9 correspond to the above-mentioned igus standard and have been approved for use in torsion applications. The following twistable CF ROBOT cable types are currently available:

n n n n

Hybrid/control cables Motor/servo cables Bus/data cables FOC cables

We can also offer you Chainflex ROBOT cables pre-fitted with the plug-in connectors of your choice as ReadyCable, or as a ready-to-install ReadyChain cable assembly.

... no minimum order quantity


4.218

Info

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.219

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Chainflex

NEW in this catalog.


CFROBOT9
PUR 180

PUR Hybrid cable, twistable Chainflex CF ROBOT9


G for twistable loads G PUR outer jacket G unshielded/shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. twisted a max. Travel distance Torsion UV-resistant Nominal voltage Testing voltage Oil Flame-retardant Silicon-free Conductor Core insulation Element shield Outer jacket 10 m/s2 Robots and movements in the 3D range, Class 1 180 , with 1 m cable length High 300/500 V (following DIN VDE 0245). 2000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363 -102), Class 3. According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). Extremely bend-resistant cable Mechanically high-quality TPE mixture. Extremely torsion resistant, tinned braided copper shield. Coverage approx. 85% optical. Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Steel blue (similar to RAL 5011) CEI CE Lead free
Image exemplary.

Highly flexible special conductor

Conductor twisted with dampening elements

-25 C to +80 C, minimum bending radius twisted 10 x d -40 C to +80 C, minimum bending radius 4 x d 10 m/s

Extremely torsion resistant copper shield

PTFE gliding foil

Pressure extruded PUR blend

Class 6.1.3

Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.220

Price index

Class 6.1.3
Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

CFROBOT9
PUR 180

Typical application area


n for maximum load requirements with torsion movements n almost unlimited resistance to oil n indoor and outdoor applications, UV-resistant n especially for robots and movements in the 3D range n Robots, handling, spindle drives Delivery program Part No. CFROBOT9.001 CFROBOT9.002 CFROBOT9.003 CFROBOT9.004 CFROBOT9.005(1) CFROBOT9.006 CFROBOT9.007 Number of cores and conductor nominal cross section [mm ]
2

External diameter approx. [mm] 9,5 12,0 10,0 18,5 19,5 20,0 18,0

Copper index [kg/km] 75 76 27 177 241 251 217

Weight [kg/km] 129 143 75 326 478 484 330

5 G 1,0 + (2x1,0)C 6 G 0,75 + (3x0,75)C 2 G 0,5 + (2 x 0,5)C 16 G 1,0 + (2x1,0)C 23 G 1,0 + (2x1,0)C 24 G 1,0 + (2x1,0)C (15x(2x0,25)C + (4x0,25)C)C

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Number of cores and Part No. CFROBOT9.001 CFROBOT9.002 CFROBOT9.003 CFROBOT9.004 CFROBOT9.005 CFROBOT9.006 conductor nominal cross section [mm2] 5 G 1,0 + (2x1,0)C 6 G 0,75 + (3x0,75)C 2 G 0,5 + (2 x 0,5)C 16 G 1,0 + (2x1,0)C 23 G 1,0 + (2x1,0)C 24 G 1,0 + (2x1,0)C

Core group

Colour code

5G1,0 (2x1,0)C 6G0,75 (3x0,75)C 2x0,5 (2x0,5)C 16G1,0 (2x1,0)C 23G1,0 (2x1,0)C 24G1,0 (2x1,0)C

Cores black with white numerals 1-4, one core green-yellow Cores black with white numerals 5-6 Cores black with white numerals 1-5, one core green-yellow Cores black with white numerals 6-8 Cores black with white numerals 1-2 Cores black with white numerals 3-4 Cores black with white numerals 1-4, 7-17, one core green-yellow Cores black with white numerals 5-6 Cores black with white numerals 1-4, 7-24, one core green-yellow Cores black with white numerals 5-6 Cores black with white numerals 1-4, 7-25, one core green-yellow Cores black with white numerals 5-6 Colour code in accordance with DIN 47100 white, green, brown, yellow (CAN-Bus)

CFROBOT9.007 (15x(2x0,25)C + (4x0,25)C)C 15x(2x0,25)C (4x0,25)C

Order example: CFROBOT9.001 in your desired length (0,5 m steps) CFROBOT9 Chainflex series .001 Code nominal cross section

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFROBOT (for up to 10 cuts of the same type) 4.221

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Robot cable

NEW in this catalog.


CFROBOT8
PUR 180

PUR Bus cable, twistable Chainflex CF ROBOT8


G for twistable loads G PUR outer jacket G shielded G oil-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. twisted a max. Travel distance Torsion 10 m/s 10 m/s2 Robots and movements in the 3D range, Class 1 180 , with 1 m cable length High 30 V 500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363 -10-2), Class 3. Flame-retardant Silicon-free Conductor Core insulation Core stranding Core identification According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). According to bus specification According to bus specification According to bus specification Delivery program Foil taping over the external layer. Torsion resistant tinned braided copper shield. Coverage approx. 80% optical. Outer jacket Low-adhesion, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) CEI
Image exemplary.

Especially bendingresistant fine-wire stranded conductor

Cores each stranded in especially short optimized pitch

-20 C to +70 C, minimum bending radius twisted 10 x d -25 C to +70 C, minimum bending radius 7,5 x d

GRP core element

Gusset-filled extruded dampening elements

PTFE gliding foil

UV-resistant Nominal voltage Testing voltage Oil

Torsion resistant copper shield

Highly abrasionresistant PUR jacket blend

Class 6.1.3

Intermediate jacket Overall shield

Following CEI 20-35

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.222

Price index

Class 6.1.3
CE Lead free Clean room Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. material/cable tested by IPA according to ISO standard 14644-1

CFROBOT8
PUR 180

Typical application area


n for maximum load requirements with torsion movements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for robots and movements in the 3D range n Robots, handling, spindle drives

Delivery program Part No. CFROBOT8.001 (Profibus) CFROBOT8.022 (Can-Bus) CFROBOT8.045 (GigE)

Number of cores and conductor nominal cross section [mm2] (2x0,35)C (4x0,5)C (4x(2x0,14)C)

External diameter approx. [mm] 8,0 7,0 8,5

Copper index [kg/km] 22 39 35

Weight [kg/km] 57 65 65

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Part No. CFROBOT8.001 CFROBOT8.022 CFROBOT8.045

Characteristic ce approx. [ ] 150 120 100

Number of cores and cross section [mm2] (2x0,35)C (4x0,5)C (4x(2x0,14)C)

Colour code

wave impedan- conductor nominal red, green white, green, brown, yellow (star-quad stranding) white-blue/blue, white-orange/orange, white-green/green, white-brown/brown

Order example: CFROBOT8.001 in your desired length (0,5 m steps) CFROBOT8 Chainflex series .001 Code nominal cross section

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFROBOT (for up to 10 cuts of the same type) 4.223

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Robot cable

NEW in this catalog.


CFROBOT4
PUR 180

PUR Measuring system cable, twistable Chainflex CF ROBOT4


G for twistable loads G PUR outer jacket G shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. tordiert a max. Travel distance Torsion UV-resistant Nominal voltage Testing voltage Oil 10 m/s2 Robots and movements in the 3D range, Class 1. 180, with 1 m cable length High 30 V 500 V Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363-10-2), Class 3. Flame-retardant Silicon-free Conductor Core insulation Element shield Outer jacket According to IEC 60332-1-2, CEI 20-34, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Extremely bend-resistant cable Mechanically high-quality TPE mixture. Extremely torsion resistant tinned braided copper shield. Coverage approx. 85% optical. Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Steel blue (similar to RAL 5011) CEI CE Lead free
Image exemplary.

Highly flexible special conductor

Conductor twisted with dampening elements

-25 C to +80 C, minimum bending radius twisted 10 x d -40 C to +80 C, minimum bending radius 4 x d 10 m/s

Extremely torsion resistant copper shield

Extremely torsion resistant copper shield

Pressure extruded PUR blend

Class 6.1.3

Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.224

Price index

Class 6.1.3
Clean room According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

CFROBOT4
PUR 180

Typical application area


n for maximum load requirements with torsion movements n almost unlimited resistance to oil n indoor and outdoor applications, UV-resistant n especially for robots and movements in the 3D range n Robots, handling, spindle drives

Delivery program Part No. CFROBOT4.001 CFROBOT4.002(1) CFROBOT4.009(1) CFROBOT4.015(1) CFROBOT4.028(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 11,0 10,5 9,0 9,0 7,5

Copper index [kg/km] 65 67 53 54 42

Weight [kg/km]

(3x(2x0,14)C+ (4x0,14) + (2x0,5))C (3x(2x0,14)C + 2x(0,5)C)C (4x(2x0,25) + (2x0,5))C (4x(2x0,14) + 4x0,5)C (2x(2x0,15) + (2x0,38))C 166 128 102 106 72

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program Part No.

Number of cores and conductor nominal cross section [mm2]

Core group

Colour code

CFROBOT4.001 (3x(2x0,14)C + (4x0,14) + (2x0,5))C 3x(2x0,14)C 4x0,14 2x0,5 CFROBOT4.002 CFROBOT4.009 CFROBOT4.015 CFROBOT4.028 (3x(2x0,14)C + 2x(0,5)C)C 3x(2x0,14)C 2x(0,5)C (4x(2x0,25) + (2x0,5))C (4x(2x0,14) + 4x0,5)C (2x(2x0,15) + (2x0,38))C 4x(2x0,25) 2x0,5 4x(2x0,14) 4x0,5 2x(2x0,15) (2x0,38)

yellow/green, black/brown, red/orange gray, blue, white-yellow, white-black brown-red, brown-blue green/yellow, black/brown, red/orange black, red brown/green, blue/violet, gray/pink, red/black white, brown brown/green, violet/yellow, gray/pink, red/black blue, white, brown-green, white-green green/yellow, pink/blue red, black

Order example: CFROBOT4.009 in your desired length (0,5 m steps) CFROBOT4 Chainflex series .009 Code nominal cross section

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFROBOT (for up to 10 cuts of the same type) 4.225

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Robot cable

NEW in this catalog.


CFROBOT5
TPE 180

TPE-Fibre optic cable, twistable Chainflex CF ROBOT5


G for twistable loads G TPE outer jacket G oil-resistant G bio-oil-resistant G UV-resistant G low-temperature-flexible G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range -25 C to +60 C, minimum bending radius 7,5 x d 10 m/s 10 m/s2 Robots and movements in the 3D range, Class 1 180 , with 1 m cable length High Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Silicon-free Fibre optic cable Core stranding Outer jacket Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). 50/125 m, 62.5/125 m special fixed wire elements with aramide strain relief. FOC wires stranded with high-tensile aramide dampers around the GRP central element. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011) CE Lead free Clean room Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 fixed v max. twisted a max. Travel distance Torsion UV-resistant Oil -20 C to +60 C, minimum bending radius twisted 12,5 x d

FOC cores with hightensile aramide fibres

GRP core element

FOC wires stranded with dampers around the GRP core

Pressure extruded, halogen-free TPE blend

Class 7.1.4

Typical application area


n for maximum load requirements with torsion movements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for robots and movements in the 3D range n Robots, handling
Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.226

Price index

Class 7.1.4
Delivery program Part No. CFROBOT5.500 CFROBOT5.501 2 2 Number of fibres Fibre diameter 62,5/125 50/125 External diameter 8,5 8,5 Weight [kg/km] 87 87 approx. [m] approx. [mm]

CFROBOT5
TPE 180

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Delivery program Part No. CFROBOT5.500 CFROBOT5.501

Bandwidth

Attenuation Bandwidth

Attenuation Colour code

with 850 nm with 850 nm with 1300 nm with 1300 nm [MHz x km] [dB/km] 160 - 200 200 - 600 3,2 2,5 - 3,5 [MHz x km] [dB/km] 200 - 500 600 - 1200 0,9 0,7 - 1,5 blue with white numbers blue with white numbers

Order example: CFROBOT5.501 in your desired length (0,5 m steps) CFROBOT5 Chainflex series .501 Code type of fibres

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFROBOT (for up to 10 cuts of the same type) 4.227

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Robot cable

NEW in this catalog.


CFROBOT6/7
PUR 180

PUR Motor cable, twistable Chainflex CF ROBOT6/7


G for twistable loads G PUR outer jacket G unshielded/shielded G oil-resistant and coolant-resistant G notch-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range -40 C to +80 C, minimum bending radius 4 x d 10 m/s 10 m/s2 Robots and movements in the 3D range, Class 1 180 , with 1 m cable length High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1, DIN EN 50363 -10-2), Class 3. Flame-retardant Silicon-free Conductor According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). Extremely bend-resistant cable Mechanically high-quality TPE mixture. Energy conductor: cores black with white numerals, one core green/yellow 1. control core: 5 Schedule delivery program 2. control core: 6 4. control core: 8 2 control pairs: cores black with white numerals. fixed v max. twisted a max. Travel distance Torsion UV-resistant Nominal voltage Testing voltage Oil -25 C to +80 C, minimum bending radius twisted 10 x d

Highly flexible special conductor

Conductor twisted with dampening elements

Extremely torsion resistant copper shield

PTFE gliding foil

Pressure extruded PUR blend

Core insulation Core identification

Class 6.1.3

3. control core: 7 Overall shield Outer jacket

4 control pairs: colour code in accordance with DIN 47100 Extremely torsion resistant, tinned braided copper shield. Coverage approx. 85% optical. Low-adhesion, halogen-free, highly abrasion-resistant mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Steel blue (similar to RAL 5011)
Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.228

Price index

Class 6.1.3
CEI CE Lead free Clean room Following CEI 20-35 Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF27.07.05.02.01.D, tested by IPA according to standard 14644-1

CFROBOT6/7
PUR 180

Typical application area


n for maximum load requirements with torsion movements n almost unlimited resistance to oil n indoor and outdoor applications, UV-resistant n especially for robots and movements in the 3D range n Robots, handling, spindle drives

Delivery program Part No. CFROBOT6.100.03(12) CFROBOT6.160.03(12) CFROBOT6.250.03


(12)

Number of cores and conductor nominal cross section [mm2] 3 G 10 3 G 16 3 G 25 3 G 35 (3 G 1,5)C (3 G 2,5)C (4 G 1,5)C (4 G 2,5)C (4 G 1,5 + 2x(2x1,5)C)C (4 G 2,5 + 2x(2x1,5)C)C (4 G 4 + 4x(2x0,25)C)C

External diameter approx. [mm] 16,5 19,0 23,5 26,0 8,0 9,5 8,5 10,5 16,5 18,5 16,5

Copper index [kg/km] 287 459 722 1020 58 89 74 115 190 230 240

Weight [kg/km] 404 601 926 1233 95 137 121 171 380 450 340

CFROBOT6.350.03(12) Without control pair CFROBOT7.15.03.C(12) CFROBOT7.25.03.C CFROBOT7.25.04.C 2 control pairs CFROBOT7.15.15.02.02.C(14) CFROBOT7.25.15.02.02.C(1/14) 4 control pairs CFROBOT7.40.02.02.04.C(14)
(12)

CFROBOT7.15.04.C(13)
(13)

(1) Delivery time upon inquiry (12) Core identification energy conductor: 1. Core: 1 2. Core: 2 (13) Core identification energy conductor: 1. Core: 1 2. Core: 2 3. Core: 3 (14) Core identification energy conductor: 1. Core: U / L1 / C / L+ 2. Core: V / L2 3. Core: W / L3 / D / LNote: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core * New in this catalog.

Order example: CFROBOT6.100.03 in your desired length (0,5 m steps) CFROBOT6 Chainflex series .100 Code nominal cross section .03 Number of cores

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFROBOT (for up to 10 cuts of the same type) 4.229

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Robot cable

CF ROBOT
TPE 90

TPE-Robot cable Chainflex CF ROBOT


G for twistable loads G TPE outer jacket, shielded G oil-resistant G bio-oil-resistant G PVC-free G UV-resistant G flame-retardant G hydrolysis-resistant and microbe-resistant
Temperature range moved -35 C to +100 C, minimum bending radius twisted 10 x d -40 C to +100 C, minimum bending radius 4 x d 10 m/s 10 m/s2 Robots and movements in the 3D range, Class 1 90 , with 1 m cable length High 600/1000 V (following DIN VDE 0250). 4000 V (following DIN VDE 0281-2). Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568 with Plantocut 8 S-MB), Class 4. Flame-retardant Silicon-free According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 192). Extremely bend-resistant cable Mechanically high-quality TPE mixture. Extremely torsion resistant tinned braided copper shield. Coverage approx. 90% optical. Outer jacket Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005) UL/CSA CEI CE
Image exemplary.

Extremely bendresistant cable

Pressure extruded TPE blend

Extremely strong rayon thread

Temperature range fixed v max. twisted a max.

PTFE gliding foil

Travel distance Torsion UV-resistant

Extremely torsion resistant copper shield

Nominal voltage Testing voltage Oil

Extremely strong rayon thread

Pressure extruded TPE blend

Conductor Core insulation Overall shield

Class 6.1.4

Style 10258 and 21387, 1000 V, 90 C Following CEI 20-35 Following 2006/95/EG

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.230

Price index

Class 6.1.4
Lead free Clean room Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF34.25.04, tested by IPA according to standard 14644-1

CF ROBOT
TPE 90

Typical application area


n for maximum load requirements with torsion movements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for robots and movements in the 3D range n Robots, handling, spindle drives Delivery program Part No. CFROBOT.035(1) CFROBOT.036 CFROBOT.037 CFROBOT.038 CFROBOT.039
(1)

Number of cores and conductor nominal cross section [mm ]


2

External diameter approx. [mm] 10,5 12,0 14,5 15,5 18,0

Copper index [kg/km] 121 183 289 391 546

Weight [kg/km] 197 274 425 534 726

(1x10,0)C (1x16,0)C (1x25,0)C (1x35,0)C (1x50,0)C

(1) Delivery time upon inquiry Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Order example: CFROBOT.035 in your desired length (0,5 m steps) CFROBOT Chainflex series .035 Code nominal cross section

Please use www.chainflex.eu/en/CFROBOT for your online order. Delivery time 24h or today*
* Delivery time means time until shipping of goods

igus Chainflex cables in application of a multi-dimensional moving energy chain Triflex R for production robots.

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFROBOT (for up to 10 cuts of the same type) 4.231

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Robot cable

ideo-, vision engineering/bus technology

amera

Chainflex ReadyCable
Cable type

Jacket Page

Video-, vision engineering/bus technology (with camera reference list FireWire USB GigE FOC FOC Koax
Ready-made cable Ready-made cable Ready-made cable Ready-made cable Ready-made cable (Robotics) Ready-made cable

page 4.224)
TPE TPE TPE PUR TPE TPE 4.234 4.238 4.242 4.244 4.248 4.250

4.233

FireWire
TPE 12,5 x d

TPE Bus cable Chainflex FireWire


G G G G G FireWire cable (IEEE 1394a) for maximum load requirements TPE outer jacket oil-resistant flame-retardant

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. UV-resistant Nominal voltage Testing voltage
Extremely bendingresistant, tinned copper shield

-35 C to +70 C, minimum bending radius 12,5 x d -40 C to +70 C, minimum bending radius 5 x d 10 m/s, 6 m/s 100 m/s2 Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568) According to IEC 60332-1-2, CEI 20-34, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality PE mixture. Cores and paires stranded with an especially short pitch length. Core 0,15 mm2: orange/blue, green/red. Core 0,34 mm2: black, white. Extremely flexible, tinned copper shield over foil taping. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Red lilac (similar to RAL 4001)

Especially bendingresistant fine-wire stranded conductor

Oil Flame-retardant Silicon-free Conductor Core insulation Core stranding Core identification Element shield Outer jacket

Cores and paires stranded with an especially short pitch length

Gusset-filled extruded, flame-retardant TPE mixture

FireWire

Image exemplary.

... no minimum order quantity

4.234

FireWire
TPE 12,5 x d

UL/CSA DESINA CE Lead free Clean room

Style 1589 and 21371, 30 V, 80 C According to VDW, DESINA standardisation

Chainflex
page 4.416)

Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

Typical application area


G Transmission lengths of up to 10 m

Test data page 4.38 Camera reference list page 4.254

More than 6.0 million movements have been successfully tested with the CFBUS.055 in E-Chains with 10 m cable length.

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.235

Fax +49-2203-96 49-222

G FireWire cable for use in E-Chains in industrial environments (Technical note

Tel. +49-2203-96 49-0

FireWire

FireWire
TPE 12,5 x d

TPE Bus cable Chainflex FireWire


G G G G G FireWire cable (IEEE 1394a) for maximum load requirements TPE outer jacket oil-resistant flame-retardant

As well available on the roll, in the lengths you require.


Part No. CFBUS.055 Number of cores and conductor nominal cross section [mm2] 2 (2 x 0,15) C+2 x (0,34) C External diameter approx. [mm] 7,5 Copper index [kg/km] 42 Weight [kg/km] 81

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Choose from the following plug-cable combinations


Connector body with clip Part No.: MAT9048160 Connector body with clip Pre-assembled on both sides

Connector body with clip MAT9048621

Pin body without clip Pre-assembled on both sides

Connector body with clip MAT9048623

Moulded connector socket without clip Pre-assembled on both sides

Connector body with clip


Image exemplary.

Formschrumpfteil Sift without clip Pre-assembled MAT9048625 on both sides

Moulded connector pin without clip MAT9048627

Moulded connector pin without clip Pre-assembled on both sides

FireWire

... no minimum order quantity


4.236

FireWire
TPE 12,5 x d

Chainflex
Pin body without clip Part No.: MAT9048620 Pin body without clip Pre-assembled on both sides Pin body without clip MAT9048622 Moulded connector socket without clip Pre-assembled Pin body without clip MAT9048624 Moulded connector pin without clip Pre-assembled on both sides Moulded connector socket without clip MAT9048626 Moulded connector socket without clip Pre-assembled on both sides Moulded connector socket without clip MAT9048628 Moulded connector pin without clip Pre-assembled on both sides

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.237

Tel. +49-2203-96 49-0

on both sides

Fax +49-2203-96 49-222

FireWire

USB
TPE 12,5 x d

TPE Bus cable Chainflex USB


G G G G G USB cable 2.0 for maximum load requirements TPE outer jacket oil-resistant flame-retardant

Especially bendingresistant fine-wire stranded conductor

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. UV-resistant Nominal voltage Testing voltage Oil Flame-retardant

-35 C to +70 C, minimum bending radius 12,5 x d -40 C to +70 C, minimum bending radius 5 x d 10 m/s, 6 m/s 100 m/s2 Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568) According to IEC 60332-1-2, CEI 20-34, FT1, VW-1 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Mechanically high-quality PE mixture. Cores and paires stranded with an especially short pitch length

Cores and paires stranded with an especially short pitch length

Extremely bendingresistant. tinned copper shield

Silicon-free Conductor Core insulation Core stranding

Pressure extruded. flame-retard TPE blend

Core identification

Core 0,5 mm2: red, black Core 0,08 mm2: white, green (CFBUS.065). Core 0,24 mm2: white. green (CFBUS.066).

Overall shield Outer jacket

Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Red lilac (similar to RAL 4001)

USB

UL/CSA DESINA CE
Image exemplary.

Style 1589 and 21371, 30 V, 80 C According to VDW, DESINA standardisation Following 2006/95/EG

... no minimum order quantity

4.238

USB
TPE 12,5 x d Lead free Clean room Following EC (RoHS) 2002/95/EC. According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

Chainflex Tel. +49-2203-96 49-0

Typical application area


G USB 2.0 cable for use in E-Chains in industrial environments (Technical note G Transmission lengths of up to 6 m (CFBUS.065) G Transmission lengths of up to 10 m (CFBUS.066) page 4.416)

Camera reference list page 4.254


Fax +49-2203-96 49-222

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.239

USB

USB
TPE 12,5 x d

TPE Bus cable Chainflex USB


G G G G G USB cable 2.0 for maximum load requirements TPE outer jacket oil-resistant flame-retardant

As well available on the roll, in the lengths you require.


Part No. Number of cores and conductor nominal cross section [mm2] (2 x 0,5+1 x (2 x 0,08))C External diameter approx. [mm] 5,0 Copper index [kg/km] 26 Weight [kg/km] 45

CFBUS.065

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Choose from the following plug-cable combinations


USB Type A Art.-Nr.: USB9040001 open end of cable Pre-assembled at one end

USB Type A USB9040010

USB Type A Pre-assembled on both sides

USB Type B USB9040020

open end of cable Pre-assembled at one end

USB Type B USB9040030


Image exemplary.

USB Type B Pre-assembled on both sides

USB Type A USB9040040

USB Type B Pre-assembled on both sides

USB Type A USB9040060

USB Type A (Socket) Pre-assembled on both sides

USB

... no minimum order quantity


4.240

USB
TPE 12,5 x d

Chainflex

As well available on the roll, in the lengths you require.


Part No. Number of cores and conductor nominal cross section [mm2] (2 x 0,5+1 x (2 x 0,24))C External diameter approx. [mm] 6,0 Copper index [kg/km] 32 Weight [kg/km] 56

CFBUS.066*

Choose from the following plug-cable combinations


USB Type A Art.-Nr.: USB9040201 open end of cable Pre-assembled at one end

USB Type A USB9040210

USB Type A Pre-assembled on both sides

USB Type B USB9040220

open end of cable Pre-assembled at one end

USB Type B USB9040230

USB Type B Pre-assembled on both sides

USB Type A USB9040240

USB Type B Pre-assembled on both sides

USB Type A USB9040260

USB Type A (Socket) Pre-assembled on both sides

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.241

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

* CFBUS.066 is delivered with form shrink hose over USB housing Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

USB

GigE
TPE 12,5 x d

TPE Bus cable Chainflex GigE


G G G G G GigE cable Ethernet special cable for heavy-duty use TPE outer jacket oil-resistant flame-retardant

Especially bendingresistant fine-wire stranded conductor

Temperature range moved Temperature range fixed


Cores and paires stranded with an especially short pitch length

-35 C to +70 C, minimum bending radius 12,5 x d -40 C to +70 C, minimum bending radius 7,5 x d 10 m/s, 6 m/s 100 m/s2 Medium 30 V 500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568) According to IEC 60332-1-2, CEI 20-34, FT1, VW-1. Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Fine-wire stranded conductor in especially bending-resistant version consisting of bare copper wires (following EN 60228). Special PP-isolating mixture 2 cores each stranded in pairs with short pitch lengths, core pairs also stranded with short pitch lengths. Colour code in accordance with DIN 47100 TPE mixture adapted to suit the requirements in Energy Chains. Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Red lilac (similar to RAL 4001)

v max. unsupported/gliding a max. UV-resistant Nominal voltage Testing voltage Oil Flame-retardant Silicon-free

Gusset-filled extruded

Extremely bendingresistant, tinned copper shield

Conductor Core insulation Core stranding Core identification Inner jacket Overall shield Outer jacket

Pressure extruded, flame-retard TPE blend

GigE

UL/CSA CE DESINA
Image exemplary.

Style 1589 and 21371, 30 V, 80 C Following 2006/95/EG According to VDW, DESINA standardisation

... no minimum order quantity

4.242

GigE
TPE 12,5 x d

Lead free Clean room

Following EC (RoHS) 2002/95/EC. According to ISO Class 1, material/cable tested by IPA according to ISO standard 14644-1

Chainflex Tel. +49-2203-96 49-0

Typical application area


G Ethernet cable for use in E-Chains in industrial environments (Technical note G Transmission lengths of up to 50 m page 4.416)

Camera reference list page 4.254


As well available on the roll, in the lengths you require.
Part No.: Number of cores and conductor nominal cross section [mm2] (4x (2 x 0,15))C (4x (2 x 0,14)C) External diameter approx. [mm] 8,0 8,5 Copper index [kg/km] 35 35 Weight [kg/km] 79 65

CFBUS.044 CFROBOT8.045

Choose from the following plug-cable combinations


Connector RJ45 Metall, 8 poles Part No.: GIG9040001 Connector RJ45 Metall, 8 poles Pre-assembled on both sides

Connector RJ45 Metall, 8 poles

Part No.: Plug made of RJ45 plastic with knurled screws Pre-assembled GIG9040002 on both sides

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.243

Fax +49-2203-96 49-222

GigE

FOC PUR 12,5 x d

PUR Fibre optic cable (FOC) Chainflex Glass fibre


G G G G Gradient glass fibre cable 50/125 m, 62.5/125 m PUR outer jacket oil-resistant UV-resistant

Gradient fibers

Temperature range moved Temperature range


Plastic covered special fiber

-20 C to +60 C, minimum bending radius 12,5 x d -25 C to +60 C, minimum bending radius 7,5 x d 10 m/s, 6 m/s 20 m/s2 High Oil-resistant (following DIN EN 60811-2-1) MUD-resistant following NEK 606 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). 50/125 m, 62.5/125 m fibres in gel-filled hollow cores. Hollow cores with integrated FOC-fibres stranded with two strain relief elements. Cores black with white numerals. Low-adhesion mixture on the basis of PUR, adapted to suit the requirements in Energy Chains (following DIN VDE 0282 Part 10). Colour: Jet black (similar to RAL 9005)

fixed v max. unsupported/gliding a max. UV-resistant Oil

Gel-filled, armored hollow core

Offshore Silicon-free Fibre cables Core stranding Core identification Outer jacket

Armored hollow cores with optimized pitch length stranded around a strain relief element

CE
Gusset-filled extruded PUR mixture

Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

Lead free

FOC

Image exemplary.

... no minimum order quantity

4.244

FOC PUR 12,5 x d

Typical application area


G Fiber optic cable for use in E-Chains in industrial environments G Transmission lengths of up to 500 m

Chainflex

Test data page 4.38 Camera reference list page 4.254


Fax +49-2203-96 49-222 Tel. +49-2203-96 49-0
Harnessed igus E6 system on a camera application.

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.245

FOC

FOC PUR 12,5 x d

PUR Fibre optic cable (FOC) Chainflex Glass fibre


G G G G Gradient glass fibre cable 50/125 m, 62.5/125 m PUR outer jacket oil-resistant UV-resistant

As well available on the roll, in the lengths you require.


Part No. Number of fibers 2 Fibre diameter approx. [m] 50/125 External diameter approx. [mm] 9.0 Weight [kg/km] 85

CFLG.2HG.MF.50/125

Connector ST

LWL90412393

Connector LC

Pre-assembled on both sides*

Connector ST

LWL90412394

Connector ST Pre-assembled on both sides

Connector LC

LWL90412395

Connector LC Pre-assembled on both sides

CFLG.2HG.MF.62.5/125

62.5/125

9.0

85

Connector ST

LWL90412396

Connector LC

Pre-assembled on both sides*

Image exemplary.

Connector ST

LWL90412397

Connector ST Pre-assembled on both sides

Connector LC

LWL90412398

Connector LC Pre-assembled on both sides

* 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).

FOC

Tube sinking LWL90428935

Closed corrugated tube to feed in Fibre optic cables (image shown cut open)

... no minimum order quantity


4.246

FOC PUR 12,5 x d

(Note: FOC patch cable extensions are for protected installation only) Part No. Number of fibers 2 Fibre diameter approx. [m] 50/125 LWL90412399 External diameter approx. [mm] 6.5 Weight [kg/km] 27 Connector LC Pre-assembled on both sides*

FFLG.2G.50/125 Connector ST

Connector ST

LWL90412400

Connector ST Pre-assembled on both sides

Connector LC

LWL90412401

Connector LC Pre-assembled on both sides

FFLG.2G.62.5/125

62.5/125

6.5

27

Connector ST

LWL90412402

Connector LC Pre-assembled on both sides*

Connector ST

LWL90412403

Connector ST Pre-assembled on both sides

Connector LC

LWL90412404

Connector LC Pre-assembled on both sides

* 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314).

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.247

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

FOC

FOC patch cables for static installation:

Chainflex

ROBOT-FOC
TPE 12,5 x d

TPE Fibre optic cables, twistable Chainflex CF ROBOT5


G for twistable loads G TPE outer jacket G oil-resistant G bio-oil-resistant G UV-resistant G low-temperature-flexible
Temperature range moved Temperature range fixed v max. twisted a max. Torsion UV-resistant 10 m/s2 180 , with 2 m cable length High Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568) Silicon-free Fibre Cables Core stranding Outer jacket Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). 50/125 m, 62.5/125 m special fixed wire elements with aramide strain relief. FOC wires stranded with high-tensile aramide dampers around the GRP central element. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. CE Lead free Clean room Following 2006/95/EG Following EC (RoHS) 2002/95/EC According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 -25 C to +60 C, minimum bending radius twisted 7,5 x d 10 m/s -20 C to +60 C, minimum bending radius twisted 12,5 x d

FOC wires with hightensile aramide fibres

GRP core element

FOC wires stranded with dampers around the GRP core

Oil

Pressure extruded, halogen-free TPE blend

Typical application area


n for maximum load requirements with torsion movements n almost unlimited resistance to oil, also with bio-oils

FOC

n indoor and outdoor applications, UV-resistant n especially for robots and movements in the 3D range n Robots, handling

Image exemplary.

... no minimum order quantity

4.248

ROBOT-FOC
TPE 12,5 x d

As well available on the roll, in the lengths you require.


Part No. Number of fibers 2 Fibre diameter approx. [m] 50/125 External diameter approx. [mm] 8.5 Weight [kg/km] 87

CFROBOT5.501

Chainflex Tel. +49-2203-96 49-0

Connector ST

LWL90422491

Connector LC Pre-assembled on both sides*

Connector ST

LWL90422492

Connector ST Pre-assembled on both sides

Connector LC

LWL90422493

Connector LC Pre-assembled on both sides

CFROBOT.500

62.5/125

8.5

87

Connector ST

LWL90422494

Connector LC Pre-assembled on both sides*

Connector ST

LWL90422495

Connector ST Pre-assembled on both sides

Connector LC

LWL90422496

Connector LC Pre-assembled on both sides

* 2 ST coupling pieces needed to be ordered extra, if used as extension cable (MAT0176314). Tube sinking LWL90428935

Closed corrugated tube to feed in Fibre optic cables (image shown cut open)

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.249

Fax +49-2203-96 49-222

FOC

CF Koax 1
TPE 10 x d

TPE Koax cable Chainflex CF Koax 1


G 75 koax cable for maximum load requirements G TPE outer jacket G oil-resistant G bio-oil-resistant G UV-resistant G hydrolysis-resistant and microbe-resistant
Temperature range moved Temperature range fixed v max. unsupported/gliding a max.

Especially bendingresistant special conductor

-35 C to +100 C, minimum bending radius 10 x d -40 C to +100 C, minimum bending radius 7,5 x d 10 m/s, 5 m/s 100 m/s2 Freely suspended and gliding travel distances up to 400 m, Class 4 High 300/300 V (following DIN VDE 0245). 1500 V Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568), Class 4 Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Multi-wire; adapted in single-wire diameter and pitch length to suit the requirements in Energy Chains. Special FEP-isolating mixture. Cores stranded in one layer with especially short pitch length. Schedule delivery program Extremely bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. TPE mixture adapted to suit the requirements in Energy Chains. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Steel blue (similar to RAL 5011)

Highly flexible braided copper shield

Travel distance UV-resistant Nominal voltage Testing voltage Oil

Elements stranded with short pitch, FEP special insulation

Silicon-free Conductor

Core insulation Core stranding Core identification Element shield

Gusset-filled extruded, halogen-free TPE mixture

Element jacket Outer jacket

KOAX

Image exemplary.

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.250

Price index

CF Koax 1
TPE 10 x d CE Lead free Clean room Following 2006/95/EG Following EC (RoHS) 2002/95/EC. According to ISO Class 1. Outer jacket material complies with CF9.15.07, tested by IPA according to standard 14644-1 The coax elements used in cables of the CF Koax1 series are comparable with a HF75-0.3/1.6 according to MIL-C-17/94-RG179 and thus fit in an RG179 plug!

Info

Typical application area


n for maximum load requirements n almost unlimited resistance to oil, also with bio-oils n indoor and outdoor applications, UV-resistant n especially for freely suspended and gliding travel distances up to 400 m n storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFKOAX1 (for up to 10 cuts of the same type)

4.251

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Koax cable

CF Koax 1
TPE 10 x d

TPE Koax cable Chainflex CF Koax 1


G 75 koax cable for maximum load requirements G TPE outer jacket G oil-resistant G bio-oil-resistant G UV-resistant G hydrolysis-resistant and microbe-resistant

As well available on the roll, in the lengths you require.


Part No. Number of fibers External diameter approx. [m] 4,5 Copper index [kg/km] 9,0 Weight [kg/km] 25

CFKoax1.01

1 coaxial element

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Choose from the following plug-cable combinations


Connector MAT90423400 Socket Pre-assembled on both sides

Connector

MAT90423401

Connector Pre-assembled on both sides

Socket

MAT90423402

Socket Pre-assembled on both sides

Connector

MAT90423403

open end of cable Pre-assembled on one side

Image exemplary.

Socket

MAT90423404

open end of cable Pre-assembled on one side

KOAX

... no minimum order quantity


4.252
eplan download, configurator, PDF catalogues, lifetime ...

Price index

CF Koax 1
TPE 10 x d

As well available on the roll, in the lengths you require.


Part No. Number of fibers

CFKoax1.05

5 coaxial elements

10,0

47

135

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Choose from the following plug-cable combinations


Connector MAT90423405 Socket Pre-assembled on both sides

Socket

MAT90423407

Socket Pre-assembled on both sides

Connector

MAT90423408

open end of cable Pre-assembled on one side

Socket

MAT90423409

open end of cable Pre-assembled on one side

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFKOAX1 (for up to 10 cuts of the same type)

4.253

Tel. +49-2203-96 49-0

Connector

MAT90423406

Connector Pre-assembled on both sides

Fax +49-2203-96 49-222

Koax cable

External diameter approx. [m]

Copper index [kg/km]

Weight [kg/km]

Content
CFBUS.065 USB up to 5 m

Camera reference list Selection chart


CFBUS.066 USB up to 10 m CFBUS.055 FireWire up to 10 m CFLG.2HG LWL up to 400 m CFBUS.044 GigE up to 50 m

Guppy F-033C Guppy F-036B Guppy F-036C Guppy F-038B Guppy F-038C Guppy F-038B NIR Guppy F-038C NIR Guppy F-044B Guppy F-044C Guppy F-044B NIR Guppy F-044C NIR Guppy F-046B Guppy F-046C Guppy F-080B Guppy F-080C Guppy F-146B Guppy F-146C Guppy F-503B Guppy F-503C Marlin F-033B Marlin F-033C Marlin F-046B Marlin F-046C Marlin F-080B Marlin F-080C Marlin F-080B 30fps Marlin F-080C 30fps Marlin F-131B Marlin F-131C Marlin F-131B NIR Marlin F-145B2 Marlin F-145C2 Marlin F-146B Marlin F-146C Marlin F-201B Marlin F-201C Oscar F-320C Oscar F-510C Oscar F-810C

Guppy F-033B Pike F-032C Fiber Pike F-100B Fiber Pike F-100C Fiber Pike F-145B Fiber Pike F-145C Fiber Pike F-210B Fiber Pike F-210C Fiber Pike F-421B Fiber Pike F-421C Fiber Pike F-505B Fiber Pike F-505C Fiber Stingray F-033B Fiber Stingray F-033C Fiber Stingray F-046B Fiber Stingray F-046C Fiber Stingray F-080B Fiber Stingray F-080C Fiber Stingray F-125B Fiber Stingray F-125C Fiber Stingray F-145B Fiber Stingray F-145C Fiber Stingray F-146B Fiber Stingray F-146C Fiber Stingray F-201B Fiber Stingray F-201C Fiber Stingray F-504B Fiber Stingray F-504C Fiber

Pike F-032B Fiber GB660, GB660c GB1380, GB1380c GB2450, GB2450c GC640, GC640c GC650, GC650c GC655, GC655c GC660, GC660c GC750, GC750c GC780, GC780C GC1020, GC1020c GC1280 GC1290, GC1290c GC1350, GC1350c GC1380, GC1380c GC1380CH, GC1380H GC1600, GC1600c GC1600CH, GC1600H GC2450, GC2450c GE640, GE640c GE650, GE650c GE680, GE680c GE1050, GE1050c GE1350, GE1350c GE1380, GE1380c GE1600, GE1600c GE1650, GE1650c GE1660, GE1660c GE1900, GE1900c GE1910, GE1910c GE2040, GE2040c GE4000, GE4000c GE4900, GE4900c GS650, GS650c GS660, GS660c GS1380, GS1380c GS2450, GS2450c

GB650, GB650c

51147 Kln, Germany

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Chainflex

ARTCAM-... 640-THERMO 320-THERMO 150P4-HDMI 150P4-HDMI-BW 130MI-HDMI 130MI-HDMI-BW 150P4-MOUT-DUAL 150P4-MOUT-DUAL-BW 130MI-MOUT-DUAL 130MI-MOUT-DUAL-BW 625KY 625KY-BW 500P II 274KY 274KY-BW

ARTCAM-... 640-THERMO 320-THERMO 150P4-HDMI 150P4-HDMI-BW 130MI-HDMI 130MI-HDMI-BW 150P4-MOUT-DUAL 150P4-MOUT-DUAL-BW 130MI-MOUT-DUAL 130MI-MOUT-DUAL-BW 625KY 625KY-BW 500P II 274KY 274KY-BW

igus GmbH www.igus.eu

4.254

info@igus.de

Camera reference list Selection chart


CFBUS.065 USB up to 5 m
ARTCAM-... 150P III 150P III -BW 445KY 445KY-BW 098 II 098 II -BW 900MI 500MI 500MI-BW 300MI 130MI 130MI-BW 036MI 036MI-BW 900SS 500SS 500SS-BW 300SS 130SS 130SS-BW 036SS 036SS-BW 022MINI 022MINI-BW

Content
CFLG.2HG LWL up to 400 m CFBUS.044 GigE up to 50 m

CFBUS.066 USB up to 10 m
ARTCAM-... 150P III 150P III -BW 445KY 445KY-BW 098 II 098 II -BW 900MI 500MI 500MI-BW 300MI 130MI 130MI-BW 036MI 036MI-BW 900SS 500SS 500SS-BW 300SS 130SS 130SS-BW 036SS 036SS-BW 022MINI 022MINI-BW

CFBUS.055 FireWire up to 10 m

igus GmbH www.igus.eu

4.255

info@igus.de

51147 Kln, Germany

A102f A102fc A311f A311fc A312f A312fc A601f A601fc A631f A631fc A641f A641fc

piA640-210gm/gc piA1000-48gm/gc piA1600-35gm/gc piA1900-32gm/gc piA2400-12gm/gc ruL1024-19gm ruL1024-36gm ruL1024-57gm ruL2048-10gm ruL2048-19gm ruL2048-30gm ruL2098-10gc scA640-70gm/gc scA640-74gm/gc scA750-60gm/gc scA780-54gm/gc scA1000-20gm/gc scA1000-30gm/gc scA1390-17gm/gc scA1400-17gm/gc scA1400-30gm/gc scA1600-14gm/gc scA1600-14gm/gc

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Chainflex

Content
CFBUS.065 USB up to 5 m

Camera reference list Selection chart


CFBUS.066 USB up to 10 m
FWX03 FWX03c FWX05c-II FWX05-II FWX06 FWX06c FWX08 FWX08c FWX131 FWX131c FWX14 FWX14c FWX20 FWX20c FWXC03c FWXC13c FWXC30c FWL120 FQX50c FQX80c

CFBUS.055 FireWire up to 10 m

CFLG.2HG LWL up to 400 m


TXGC03 TXGC03c TXG03 [-P] TXG03c [-P] TXG04 [-P] TXG04c [-P] TXG06 [-P] TXG06c [-P] TXG08 [-P] TXG08c [-P] TXG13 [-P] TXG13c [-P] TXG14 [-P] TXG14c [-P] TXG14f [-P] TXG14cf [-P] TXG20 [-P] TXG20c [-P] TXG50 [-P] TXG50c [-P]

CFBUS.044 GigE up to 50 m

Chainflex

igus GmbH

4.256

info@igus.de

www.igus.eu

51147 Kln, Germany

UI-1220-M/C UI-1540-M UI-1640-C UI-1550-C UI-1460-C UI-1480-M/C UI-2210-M/C UI-2410-M/C UI-2220-M/C UI-2230-M/C UI-2240-M/C UI-2250-M/C UI-1220RE-M/C UI-1540RE-M UI-1640RE-C UI-1550RE-C UI-1460RE-C UI-1480RE-M/C UI-2210RE-M/C UI-2410RE-M/C UI-2220RE-M/C UI-2230RE-M/C UI-2240RE-M/C UI-2250RE-M/C

UI-1220RE-M/C UI-1540RE-M UI-1640RE-C UI-1550RE-C UI-1460RE-C UI-1480RE-M/C UI-2210RE-M/C UI-2410RE-M/C UI-2220RE-M/C UI-2230RE-M/C UI-2240RE-M/C UI-2250RE-M/C

UI-5220SE-M/C UI-5540SE-M UI-5640SE-C UI-5550SE-C UI-5460SE-C UI-5480SE-M/C UI-6210SE-M/C UI-6410SE-M/C UI-6220SE-M/C UI-6230SE-M/C UI-6240SE-M/C UI-6250SE-M/C UI-5220HE-M/C UI-5540HE-M UI-5640HE-C UI-5550HE-C UI-5460HE-C UI-5480HE-M/C UI-6210HE-M/C UI-6410HE-M/C UI-6220HE-M/C UI-6230HE-M/C UI-6240HE-M/C UI-6250HE-M/C

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Camera reference list Selection chart


CFBUS.065 USB up to 5 m
DMK 21AU04 DFK 21AU04 DBK 21AU04 DMK 31AU03 DFK 31AU03 DBK 31AU03 DMK 41AU02 DFK 41AU02 DBK 41AU02 DMK 21BU04 DFK 21BU04 DBK 21BU04 DMK 31BU03 DFK 31BU03 DBK 31BU03 DMK 41BU02 DFK 41BU02 DBK 41BU02 DMK 21BU04.H DFK 21BU04.H DBK 21BU04.H DMK 31BU03.H DFK 31BU03.H DBK 31BU03.H DMK 41BU02.H DFK 41BU02.H DBK 41BU02.H

Content
CFLG.2HG LWL up to 400 m CFBUS.044 GigE up to 50 m

CFBUS.066 USB up to 10 m
DMK 21AU04 DFK 21AU04 DBK 21AU04 DMK 31AU03 DFK 31AU03 DBK 31AU03 DMK 41AU02 DFK 41AU02 DBK 41AU02 DMK 21BU04 DFK 21BU04 DBK 21BU04 DMK 31BU03 DFK 31BU03 DBK 31BU03 DMK 41BU02 DFK 41BU02 DBK 41BU02 DMK 21BU04.H DFK 21BU04.H DBK 21BU04.H DMK 31BU03.H DFK 31BU03.H DBK 31BU03.H DMK 41BU02.H DFK 41BU02.H DBK 41BU02.H

CFBUS.055 FireWire up to 10 m
DMK 21F04 DFK 21F04 DMK 21AF04 DFK 21AF04 DBK 21AF04 DMK 31AF03 DFK 31AF03 DBK 31AF03 DMK 41AF02 DFK 41AF02 DBK 41AF02 DMK 21BF04 DFK 21BF04 DBK 21BF04 DMK 31BF03 DFK 31BF03 DBK 31BF03 DMK 41BF02 DFK 41BF02 DBK 41BF02 DMK 21BF04.H DFK 21BF04.H DBK 21BF04.H DMK 31BF03.H DFK 31BF03.H DBK 31BF03.H DMK 41BF02.H DFK 41BF02.H DBK 41BF02.H DMK 21AF04-Z DFK 21AF04-Z DBK 21AF04-Z DMK 31AF03-Z DFK 31AF03-Z DBK 31AF03-Z DMK 21BF04-Z DFK 21BF04-Z DBK 21BF04-Z DMK 31BF03-Z DFK 31BF03-Z DBK 31BF03-Z DMK 21BF04-Z.H DFK 21BF04-Z.H DBK 21BF04-Z.H DMK 31BF03-Z.H DFK 31BF03-Z.H DBK 31BF03-Z.H

igus GmbH www.igus.eu

4.257

info@igus.de

51147 Kln, Germany

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Chainflex

etwork-/Ethernet-/FOC-cable/Fieldbus

etwork

Chainflex ReadyCable
Cable type

Jacket

Page

Network-/Ethernet-/FOC-cable/Fieldbus CFLG.6G CFLG.12G CAT5 CAT5 CAT6 Profibus NEW* NEW*


Gradient fibre glass cable, ready-made Gradient fibre glass cable, ready-made Ethernet cable, ready-made Ethernet cable, ready-made, L-/T-angle Ethernet cable, ready-made Field bus cable, ready-made TPE TPE TPE TPE TPE PVC/PUR/TPE 4.260 4.262 4.264 4.266 4.268 4.270

* New in this catalog.

4.259

CFLG.6G TPE 15 x d

TPE Fibre optic cable Chainflex Fibre Optic


G Gradient glass-fiber cable for heavy-duty use G TPE outer jacket G halogen-free G low-temperature-flexible up to -40 C

Gradient fibers

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. UV-resistant Oil Silicon-free Halogen-free
Stranded GRP rods

-40 C to +60 C, minimum bending radius 15 x d -40 C to +60 C, minimum bending radius 8.5 x d 10 m/s, 6 m/s 20 m/s2 High Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568) Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. 50/125 m, 62.5/125 m fibres in gel-filled hollow cores. Stranded GRP rods with integrated torsion protection braid in the outer jacket over gel-filled fiber sheath. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005)

Gel-filled fiber sheath

Fibre cables Core stranding Outer jacket

CE Lead free
Highly abrasionresistant TPE blend with integrated torsion protection braid

Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

Typical application area


n for maximum load requirements n Maximum EMC protection, with high transmission qualities in terms of glass-specific requirements n almost unlimited resistance to oil, also with bio-oils n Indoor and outdoor applications n only for freely suspended and gliding travel distances up to 500 m and more n Outdoor ship to shore, crane applications, conveyer technology

Fibre Optic

Image exemplary.

... no minimum order quantity

4.260

Price index 15x

CFLG.6G TPE 15 x d

Chainflex TPE gradient glass-fiber cable


Delivery program igus Part No. Number of cores and conductor nominal cross section [mm2] [mm]

Chainflex
11.5 11.5 11.5 11.5 11.5 11.5

Test data page 4.40

On both ends BFOC(ST) connectors On both ends BFOC(ST) connectors incl. conversion to SC On both ends BFOC(ST) connectors incl. conversion to LC On both ends BFOC(ST) connectors On both ends BFOC(ST) connectors incl. conversion to SC On both ends BFOC(ST) connectors incl. conversion to LC

LWL9040030 LWL9040031 LWL9040032 LWL9040045 LWL9040046 LWL9040047

6x50/125 6x50/125 6x50/125 6x62.5/125 6x62.5/125 6x62.5/125

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Tube sinking LWL90428936

Closed corrugated tube to feed in Fibre optic cables (image shown cut open)

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.261

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Fibre Optic

CFLG.12G TPE 15 x d

TPE Fibre optic cable Chainflex Fibre Optic


G Gradient glass-fiber cable for heavy-duty use G TPE outer jacket G halogen-free G low-temperature-flexible up to -40 C

Gradient fibers

Temperature range moved Temperature range fixed v max. unsupported/gliding a max. UV-resistant Oil Silicon-free Halogen-free
Stranded GRP rods

-40 C to +60 C, minimum bending radius 15 x d -40 C to +60 C, minimum bending radius 8.5 x d 10 m/s, 6 m/s 20 m/s2 High Oil-resistant (following DIN EN 60811-2-1), bio-oil-resistant (following VDMA 24568) Free from silicon which can affect paint adhesion (following PV 3.10.7 status 1992). Following EN 50267-2-1. 50/125 m, 62.5/125 m fibres in gel-filled hollow cores. Stranded GRP rods with integrated torsion protection braid in the outer jacket over gel-filled fiber sheath. Low-adhesion mixture on the basis of TPE, especially abrasionresistant and highly flexible, adapted to suit the requirements in Energy Chains. Colour: Jet black (similar to RAL 9005)

Gel-filled fiber sheath

Fibre cables Core stranding Outer jacket

CE Lead free
Highly abrasionresistant TPE blend with integrated torsion protection braid

Following 2006/95/EG Following EC (RoHS) 2002/95/EC.

Typical application area


n for maximum load requirements n Maximum EMC protection, with high transmission qualities in terms of glass-specific requirements n almost unlimited resistance to oil, also with bio-oils n Indoor and outdoor applications n only for freely suspended and gliding travel distances up to 500 m and more n Outdoor ship to shore, crane applications, conveyer technology

Fibre Optic

Image exemplary.

... no minimum order quantity

4.262

Price index 15x

CFLG.12G TPE 15 x d

Chainflex TPE gradient glass-fiber cable


Delivery program igus Part No. Number of cores and conductor nominal cross section [mm2] [mm]

Chainflex
11.5 11.5 11.5 11.5 11.5 11.5

Test data page 4.40

On both ends BFOC(ST) connectors On both ends BFOC(ST) connectors incl. conversion to SC On both ends BFOC(ST) connectors incl. conversion to LC On both ends BFOC(ST) connectors On both ends BFOC(ST) connectors incl. conversion to SC On both ends BFOC(ST) connectors incl. conversion to LC

LWL9040060 LWL9040061 LWL9040062 LWL9040075 LWL9040076 LWL9040077

12x50/125 12x50/125 12x50/125 12x62.5/125 12x62.5/125 12x62.5/125

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits.

Tube sinking LWL90428936

Closed corrugated tube to feed in Fibre optic cables (image shown cut open)

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.263

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Fibre Optic

CAT5

Chainflex network technique


CAT5 cables harnessed
Technical information
n oil-resistant n UV-resistant n halogen-free n external jacket on the basis of TPE n Shield: extremely bending-resistant copper shield with greatest possible coverage over aluminiumcoated plastic foil. n Temperature range (moved): -35 C to +70 C

Chainflex-TPE Energy Chains Ethernet special cable


Delivery program igus Part No. Number of cores and conductor nominal cross section [mm2] [mm] Bending radius

CAT5 4 pole Straight CAT9040001 (2x2x0.25)C 7.0 12,5 x d

CAT5 8 pole Straight CAT9040020 (4x2x0.15)C 8.0 12,5 x d

CAT5 8 pole Straight CAT9040060 (4x2x0.15)C 8.0 12,5 x d

CAT5 8 pole Straight CAT9040100 (4x2x0.15)C 8.0 12,5 x d

CAT5 8 pole

Network technique

Straight

CAT9040140

(4x2x0.15)C

8.0

12,5 x d

CAT5 8 pole Straight CAT9040180 (4x2x0.15)C 8.0 12,5 x d


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

... no minimum order quantity


4.264

12.5x

CAT5

12.5 x cable diameter

Chainflex-TPE Energy Chains Ethernet special cable


Delivery program igus Part No. Number of cores and conductor nominal cross section [mm2] [mm] Bending radius

Chainflex Tel. +49-2203-96 49-0

n Colour: Red lilac (similar to RAL 4001)

CAT5 8 pole Cross-Over CAT9040040 (4x2x0.15)C 8.0 12,5 x d

CAT5 8 pole Cross-Over CAT9040080 (4x2x0.15)C 8.0 12,5 x d

CAT5 8 pole Cross-Over CAT9040120 (4x2x0.15)C 8.0 12,5 x d

CAT5 8 pole Cross-Over CAT9040160 (4x2x0.15)C 8.0 12,5 x d

CAT5 8 pole Cross-Over CAT9040200 (4x2x0.15)C 8.0 12,5 x d


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.265

Fax +49-2203-96 49-222

network technique

n Minimum bending radius for use in Energy Chains:

NEW in this catalog.


CAT5

Chainflex network technique


CAT5 cables harnessed
Technical information
n oil-resistant n UV-resistant n halogen-free n external jacket on the basis of TPE n Shield: extremely bending-resistant copper shield with greatest possible coverage over aluminiumcoated plastic foil. n Temperature range (moved): -35 C to +70 C

Chainflex-TPE Energy Chains Ethernet special cable


Connector 01
L-angle curve lower

Connector 02

L-angle curve above

Connector 03

T-angle curve outer

Connector 04 Connector 05

T-angle curve inward

straight

Network technique

... no minimum order quantity


4.266

12.5x

CAT5

12.5 x cable diameter

Chainflex-TPE Energy Chains Ethernet special cable


Delivery program 8-pole Straight Part No. CAT9040380 CAT9040540 CAT9040560 CAT9040320 CAT9040360 CAT9040340 CAT9040500 CAT9040520 CAT9040300 CAT9040440 CAT9040480 CAT9040400 CAT9040460 CAT9040420 1 1 1 1 2 2 2 2 2 3 3 3 4 4 Pre-assembled with connector combination 2 3 4 5 1 2 3 4 5 3 4 5 4 5 Number of cores [mm] and conductor nominal cross section [mm2] (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 Bending radius

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Delivery program 8-pole Cross-Over Part No. CAT9040390 CAT9040550 CAT9040570 CAT9040330 CAT9040370 CAT9040350 CAT9040510 CAT9040530 CAT9040310 CAT9040450 CAT9040490 CAT9040410 CAT9040470 CAT9040430

Pre-assembled with connector combination 1 1 1 1 2 2 2 2 2 3 3 3 4 4 2 3 4 5 1 2 3 4 5 3 4 5 4 5

Number of cores [mm] and conductor nominal cross section [mm2] (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C (4x)2x0,15)C 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0

Bending radius

12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.267

Fax +49-2203-96 49-222

(4x)2x0,15)C

8,0

12,5

Tel. +49-2203-96 49-0

Chainflex

n Colour: Red lilac (similar to RAL 4001)

network technique

n Minimum bending radius for use in Energy Chains:

CAT6

Chainflex network technique


CAT6 cables harnessed
Technical information
n oil-resistant n UV-resistant n halogen-free n external jacket on the basis of TPE n Shield: extremely bending-resistant copper shield with greatest possible coverage over aluminiumcoated plastic foil. n Temperature range (moved): -35 C to +70 C

Chainflex-TPE Energy Chains Ethernet special cable


Delivery program igus Part No. Number of cores and conductor nominal cross section [mm2] [mm] Bending radius

CAT6 8 pole Straight CAT9040600 (4x(2x0.14)C)C 10.0 12,5 x d

CAT6 8 pole Straight CAT9040640 (4x(2x0.14)C)C 10.0 12,5 x d

CAT6 8 pole Straight CAT9040680 (4x(2x0.14)C)C 10.0 12,5 x d


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

Network technique

... no minimum order quantity


4.268

12.5x

CAT6

12.5 x cable diameter

Chainflex-TPE Energy Chains Ethernet special cable


Delivery program igus Part No. Number of cores and conductor nominal cross section [mm2] [mm] Bending radius

Chainflex Tel. +49-2203-96 49-0

n Colour: Red lilac (similar to RAL 4001)

CAT6 8 pole Cross-Over CAT9040620 (4x(2x0.14)C)C 10.0 12,5 x d

CAT6 8 pole Cross-Over CAT9040660 (4x(2x0.14)C)C 10.0 12,5 x d

CAT6 8 pole Cross-Over CAT9040700 (4x(2x0.14)C)C 10.0 12,5 x d


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.269

Fax +49-2203-96 49-222

network technique

n Minimum bending radius for use in Energy Chains:

NEW in this catalog.


Profibus
PVC

Chainflex network technique


Profibus cables pre-assembled
Technical information
n Oil-resistant n UV-resistant n Flame-retardant n External jacket on the basis of PVC n Total shield: bending-resistant, tinned braided copper shield. Coverage approx. 55 % linear, approx. 80 % optical. n Minimum bending radius for use in Energy Chains: 12.5 x cable diameter

Chainflex-PVC Profibus special cable


Connector 01 Connector 02 Connector 03
M12, 5-pole socket, straight M12, 5-pole pin, straight

M12, 5-pole pin, angled

Connector 04

M12, 5-pole socket, angled

Connector 05

M12, 5-pole socket, angled

Connector 06

M12, 5-pole pin, angled

Connector 07* Connector 08*

D-SUB, 9-pole pin, straight

SUB-D, 9-pole pin, 90, End plug

Connector 09*

SUB-D, 9-pole pin, 45, IP67

Connector 10*

SUB-D, 9-pole pin, End plug, 45

Network technique

Connector 11*

SUB-D, 9-pole socket/pin, pass, angled 45

Connector 12* Connector 13

SUB-D, 9-pole socket/pin, pass, angled 90

open end of cable

* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled. More combinations on request.

... no minimum order quantity


4.270

Profibus
PVC

DIN EN 60811, part 1-4 chapter 8.2, +5 C to +70 C for use in Energy Chains with > 50.000 cycle n Colour: Red lilac (similar to RAL 4001)

Chainflex-PVC Profibus special cable


Delivery program Part No. Pre-assembled with connector combination BUS9041004 BUS9041001 BUS9041011 BUS9041006 BUS9041005 BUS9041002 BUS9041013 BUS9041007 BUS9041054 BUS9041059 BUS9041062 BUS9041055 BUS9041003 BUS9041066 BUS9041064 BUS9041065 BUS9041014 BUS9041010 BUS9041012 BUS9041009 BUS9041008 BUS9041053 BUS9041056 BUS9041061 BUS9041060 BUS9041063 BUS9041052 BUS9041057 BUS9041058 BUS9041051 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 4 5 5 5 6 6 7 7 8 9 9 10 10 11 12 1 2 5 6 13 2 5 6 7 8 9 10 13 4 13 13 5 6 13 6 13 IN 2/OUT 1 13 IN 2/OUT 1 IN 2/OUT 1 13 IN 2/OUT 1 13 IN 2/OUT 1 Number of cores and conductor nominal cross section [mm2] (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 [mm] Bending radius

IN 13/OUT 13 (2x0,25)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.271

Fax +49-2203-96 49-222

(2x0,25)C

8,0

12,5

Tel. +49-2203-96 49-0

network technique

n Temperatur range (moved): -5 C to +70 C following

Chainflex

NEW in this catalog.


Profibus
PUR

Chainflex network technique


Profibus cables pre-assembled
Technical information
n Oil-resistant and coolant-resistant n UV-resistant n Flame-retardant n External jacket on the basis of PUR n Total shield: bending-resistant, tinned braided copper shield. Coverage approx. 55 % linear, approx. 80 % optical. n Minimum bending radius for use in Energy Chains: 12.5 x cable diameter

Chainflex-PUR Profibus special cable


Connector 01 Connector 02 Connector 03
M12, 5-pole socket, straight M12, 5-pole pin, straight

M12, 5-pole pin, angled

Connector 04

M12, 5-pole socket, angled

Connector 05

M12, 5-pole socket, angled

Connector 06

M12, 5-pole pin, angled

Connector 07* Connector 08*

D-SUB, 9-pole pin, straight

SUB-D, 9-pole pin, 90, End plug

Connector 09*

SUB-D, 9-pole pin, 45, IP67

Connector 10*

SUB-D, 9-pole pin, End plug, 45

Network technique

Connector 11*

SUB-D, 9-pole socket/pin, pass, angled 45

Connector 12* Connector 13

SUB-D, 9-pole socket/pin, pass, angled 90

open end of cable

* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled. More combinations on request.

... no minimum order quantity


4.272

Profibus
PUR

n Colour: Red lilac (similar to RAL 4001)

Chainflex-PUR Profibus special cable


Delivery program Part No. Pre-assembled with connector combination BUS9041104 BUS9041101 BUS9041111 BUS9041106 BUS9041105 BUS9041102 BUS9041113 BUS9041107 BUS9041154 BUS9041159 BUS9041162 BUS9041155 BUS9041103 BUS9041166 BUS9041164 BUS9041165 BUS9041114 BUS9041110 BUS9041112 BUS9041109 BUS9041108 BUS9041153 BUS9041156 BUS9041161 BUS9041160 BUS9041163 BUS9041152 BUS9041157 BUS9041158 BUS9041151 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 4 5 5 5 6 6 7 7 8 9 9 10 10 11 12 1 2 5 6 13 2 5 6 7 8 9 10 13 4 13 13 5 6 13 6 13 IN 2/OUT 1 13 IN 2/OUT 1 IN 2/OUT 1 13 IN 2/OUT 1 13 IN 2/OUT 1 Number of cores and conductor nominal cross section [mm2] (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 [mm] Bending radius

IN 13/OUT 13 (2x0,25)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.273

Fax +49-2203-96 49-222

(2x0,25)C

8,0

12,5

Tel. +49-2203-96 49-0

network technique

n Temperature range (moved): -35 C to +70 C

Chainflex

NEW in this catalog.


Profibus
TPE

Chainflex network technique


Profibus cables pre-assembled
Technical information
n Oil-resistant n UV-resistant n Flame-retardant n External jacket on the basis of TPE n Total shield: Extrem bending-resistant, tinned braided copper shield. Coverage approx. 70% linear, approx. 90% optical. n Minimum bending radius for use in Energy Chains: 10-12.5 x cable diameter

Chainflex-TPE Profibus special cable


Connector 01 Connector 02 Connector 03
M12, 5-pole socket, straight M12, 5-pole pin, straight

M12, 5-pole pin, angled

Connector 04

M12, 5-pole socket, angled

Connector 05

M12, 5-pole socket, angled

Connector 06

M12, 5-pole pin, angled

Connector 07* Connector 08*

D-SUB, 9-pole pin, straight

SUB-D, 9-pole pin, 90, End plug

Connector 09*

SUB-D, 9-pole pin, 45, IP67

Connector 10*

SUB-D, 9-pole pin, End plug, 45

Network technique

Connector 11*

SUB-D, 9-pole socket/pin, pass, angled 45

Connector 12* Connector 13

SUB-D, 9-pole socket/pin, pass, angled 90

open end of cable

* Plugs with IN and OUT connection always will be connected on the IN side if the cable is assembled. More combinations on request.

... no minimum order quantity


4.274

Profibus
TPE

n Colour: Red lilac (similar to RAL 4001)

Chainflex-TPE Profibus special cable


Delivery program Part No. Pre-assembled with connector combination BUS9041204 BUS9041201 BUS9041211 BUS9041206 BUS9041205 BUS9041202 BUS9041213 BUS9041207 BUS9041254 BUS9041259 BUS9041262 BUS9041255 BUS9041203 BUS9041266 BUS9041264 BUS9041265 BUS9041214 BUS9041210 BUS9041212 BUS9041209 BUS9041208 BUS9041253 BUS9041256 BUS9041261 BUS9041260 BUS9041263 BUS9041252 BUS9041257 BUS9041258 BUS9041251 1 1 1 1 1 2 2 2 2 2 2 2 2 3 3 4 5 5 5 6 6 7 7 8 9 9 10 10 11 12 1 2 5 6 13 2 5 6 7 8 9 10 13 4 13 13 5 6 13 6 13 IN 2/OUT 1 13 IN 2/OUT 1 IN 2/OUT 1 13 IN 2/OUT 1 13 IN 2/OUT 1 Number of cores and conductor nominal cross section [mm2] (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C (2x0,25)C 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 8,0 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 [mm] Bending radius

IN 13/OUT 13 (2x0,25)C

Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


(for up to 10 cuts of the same type) 4.275

Fax +49-2203-96 49-222

(2x0,25)C

8,0

12,5

Tel. +49-2203-96 49-0

network technique

n Temperature range (moved): -35 C to +70 C

Chainflex

nitiators

F.INI

Chainflex ReadyCable
Cable type

Jacket Page

Initiators CF9 - CF.INI (minimum bending radius 5 x d)


Direct line M12 x 1, straight/angled Direct line M12 x 1, straight/angled, LED Connecting cable M12 x 1, straight/angled Direct line M8 x 1, straight/angled Direct line M8 x 1, angled, LED Connecting cable M8 x 1, straight/angled TPE TPE TPE TPE TPE TPE 4.278 4.279 4.280 4.281 4.282 4.283

Initiators CF10 CF.INI (minimum bending radius 5 x d) 360 shielded


Direct line M12 x 1, straight/angled Connecting cable M12 x 1, straight/angled TPE TPE 4.284 4.285

Initiators CF98 - CF.INI (minimum bending radius 4 x d)


Direct line M12 x 1, straight/angled Connecting cable M12 x 1, straight/angled Direct line M8 x 1, straight/angled Connecting cable M8 x 1, straight/angled TPE TPE TPE TPE 4.286 4.287 4.288 4.289

4.277

CF.INI CF9

CF.INI
Chainflex Sensor/actuator cables with 5xd for Energy Chains Direct line M12 x 1: Socket with free cable end
Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Number of poles Ampacity Rated voltage of a winding Number of poles Ampacity Rated voltage of a winding Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M12 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton) 4- po l e 4A max. 250 V 5- p o l e (4-pole + PE) 4A max. 60 V 10 9 5 m 3/2 -40 ... +105 C IP69K, in screwed state max. 100 insertion cycles
1 BN 4 BK 2 WH 1 BN 5 GY 4 BK 3 BU 1 BN 5 GY 4 BK

BG
15

M12 x 1

BW
26,5

M12 x 1

42 10,2 11,6 12

15
8,8 11,6

31,5 12

2 WH 3 BU 1 BN

2 WH 3 BU 4 BK 2 WH 3 BU

CF9.03.04.INI* (4 x 0.34) Type CF.INI-P4-M12-BG-3 CF.INI-P4-M12-BG-5 CF.INI-P4-M12-BG-7 CF.INI-P4-M12-BG-10 CF.INI-P4-M12-BG-15 CF9.03.05.INI* (5 x 0.34) CF.INI-P5-M12-BG-3 CF.INI-P5-M12-BG-5 CF.INI-P5-M12-BG-7 CF.INI-P5-M12-BG-10 CF.INI-P5-M12-BG-15 CF9.03.04.INI* (4 x 0.34) CF.INI-P4-M12-BW-3

Part No. MAT9043700 MAT9043701 MAT9043702 MAT9043703 MAT9049426 MAT9043737 MAT9043738 MAT9043739 MAT9043740 MAT90410077

Number of Cable length poles 4 4 4 4 4 5 5 5 5 5 [m] 3,0 5,0 7,0 10,0 15,0 3,0 5,0 7,0 10,0 15,0

MAT9043704 MAT9043705 MAT9043706 MAT9043707 MAT9049430 MAT9043742 MAT9043743 MAT9043744 MAT9043745 MAT90410078

4 4 4 4 4 5 5 5 5 5

3,0 5,0 7,0 10,0 15,0 3,0 5,0 7,0 10,0 15,0

Sensor/actuator cables

CF.INI-P4-M12-BW-5 CF.INI-P4-M12-BW-7 CF.INI-P4-M12-BW-10 CF.INI-P4-M12-BW-15 CF9.03.05.INI* (5 x 0.34) CF.INI-P5-M12-BW-3 CF.INI-P5-M12-BW-5 CF.INI-P5-M12-BW-7 CF.INI-P5-M12-BW-10 CF.INI-P5-M12-BW-15
* Technical information page 4.80

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.278

5x

CF.INI CF9

Direct line M12 x 1: Socket with LED and free cable end
Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Coupling, M12 x 1 Plastic, TPU, transparent Metal, CuZn, nickel-plated Plastic, PA6GF, transparent Metal, CuZn, gold-plated Plastic, FPM (Viton)
M12 x 1

26,5

LEDs

15

LED
45,5

M12 x 1 15
8,8 11,6

Number of poles Ampacity Rated voltage of a winding Insulation resistance Contact resistance Degree of soiling Operating voltage display Switching state display Switching function Ambient temperature of plug-type connector Protection class Mechanical service life

4- p o l e 4A 10...30 V 10 9 5 m 3/2 LED green LED yellow/yellow pnp -40 ... +105 C IP66, in screwed state max. 100 insertion cycles

10,2 11,6

31,5 12

12

2 WH 1 BN 4 BK
1+ GN 4 YE 2 3 BN BK WH BU 3 1+

2 WH

4 BK
BN GN 4 YE 2 YE BU WH BK

CF9.03.04.INI* (4 x 0.34) Type CF.INI-P4-M12-BGL2-3 CF.INI-P4-M12-BGL2-5 CF.INI-P4-M12-BGL2-7 CF.INI-P4-M12-BGL2-10 CF.INI-P4-M12-BGL2-15

Part No. MAT9043708 MAT9043709 MAT9043710 MAT9043711 MAT90410087

Number of Cable length poles 4 4 4 4 4 [m] 3,0 5,0 7,0 10,0 15,0

CF9.03.04.INI* (4 x 0.34) CF.INI-P4-M12-BWL3-3 CF.INI-P4-M12-BWL3-5 CF.INI-P4-M12-BWL3-7 CF.INI-P4-M12-BWL3-10 CF.INI-P4-M12-BWL3-15


* Technical information page 4.80

MAT9043712 MAT9043713 MAT9043714 MAT9043715 MAT90410088

4 4 4 4 4

3,0 5,0 7,0 10,0 15,0

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFINI (for up to 10 cuts of the same type) 4.279

Tel. +49-2203-96 49-0

3 BU

1 BN

3 BU

Fax +49-2203-96 49-222

Chainflex

BGL

BWL

CF.INI CF9

CF.INI
Chainflex Sensor/actuator cables with 5xd for Energy Chains Connection cable M12 x 1: Socket, cable end with pin
Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Plug-type connector Handle base Union nut/screw Contact base Contacts Rated voltage of a winding Ampacity Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M12 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton) Connector, M12 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, TPU, black Metal, CuZn, gold-plated

BG
M12 x 1 15
M12 x 1 15

SG

BW
26,5

M12 x 1
52

42 10,2 11,6 12
10,2 11,6 12

15
8,8 11,6

31,5 12

4-pole: max. 250 V 5- p o l e (4-pole+PE): max. 60 V 2 WH 4A 10 9 1 BN 3 BU 3 BU 5 m 3/2 4 BK -40 ... +105 C IP69K, in screwed state max. 100 insertion cycles
2 WH 1 BN 5 GY 4 BK 3 BU 3 BU

2 WH 1 BN 1 BN 4 BK 2 WH 1 BN 1 BN 5 GY

2 WH 3 BU 4 BK 2 WH 3 BU 4 BK

5 GY 4 BK

CF9.03.04.INI* (4 x 0.34) Type CF.INI-P4-M12-BG / M12-SG-2 CF.INI-P4-M12-BG / M12-SG-5 CF.INI-P4-M12-BG / M12-SG-10

Part No. MAT90410312 MAT90410313 MAT90410314

Number of Cable length poles 4 4 4 [m] 2,0 5,0 10,0

CF9.03.05.INI* (5 x 0.34) CF.INI-P5-M12-BG / M12-SG-2 CF.INI-P5-M12-BG / M12-SG-5 CF.INI-P5-M12-BG / M12-SG-10 MAT90410339 MAT90410340 MAT90410341 5 5 5 2,0 5,0 10,0

CF9.03.04.INI* (4 x 0.34) CF.INI-P4-M12-BW / M12-SG-2 MAT90410315 MAT90410316 MAT90410317 4 4 4 2,0 5,0 10,0 CF.INI-P4-M12-BW / M12-SG-5 CF.INI-P4-M12-BW / M12-SG-10

Sensor/actuator cables

CF9.03.05.INI* (5 x 0.34) CF.INI-P5-M12-BW / M12-SG-2 CF.INI-P5-M12-BW / M12-SG-5 CF.INI-P5-M12-BW / M12-SG-10


* Technical information page 4.80

MAT90410342 MAT90410343 MAT90410344

5 5 5

2,0 5,0 10,0

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.280

5x

CF.INI CF9

Direct line M8 x 1: Socket with free cable end


Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Number of poles Ampacity Rated voltage of a winding Number of poles Ampacity Rated voltage of a winding Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M8 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton) 3- p o l e 4A max. 60 V 4- p o l e 4A max. 30 V 10 9 5 m 3/2 -40 ... +105 C IP69K, in screwed state max. 100 insertion cycles
3 BU

M8 x 1

9,6 34

16,5

M8 x 1 9,5 28

4 BK 1 BN 3 BU

4 BK

4 BK 3 BU

2 WH 1 BN

4 BK 3 BU

2 WH 1 BN

CF9.02.03.INI* (3 x 0.25) Type CF.INI-P3-M8-BG-3 CF.INI-P3-M8-BG-5 CF.INI-P3-M8-BG-7 CF.INI-P3-M8-BG-10 CF.INI-P3-M8-BG-15 CF9.03.04.INI* (4 x 0.34) CF.INI-P4-M8-BG-3 CF.INI-P4-M8-BG-5 CF.INI-P4-M8-BG-7 CF.INI-P4-M8-BG-10 CF.INI-P4-M8-BG-15 CF9.02.03.INI* (3 x 0.25) CF.INI-P3-M8-BW-3 CF.INI-P3-M8-BW-5 CF.INI-P3-M8-BW-7 CF.INI-P3-M8-BW-10 CF.INI-P3-M8-BW-15 CF9.03.04.INI* (4 x 0.34) CF.INI-P4-M8-BW-3 CF.INI-P4-M8-BW-5 CF.INI-P4-M8-BW-7 CF.INI-P4-M8-BW-10 CF.INI-P4-M8-BW-15
* Technical information page 4.80

Part No. MAT9043716 MAT9043717 MAT9043718 MAT9043719 MAT9049416 MAT9043728 MAT9043729 MAT9043730 MAT9043731 MAT9049466

Number of Cable length poles 3 3 3 3 3 4 4 4 4 4 [m] 3,0 5,0 7,0 10,0 15,0 3,0 5,0 7,0 10,0 15,0

MAT9043724 MAT9043725 MAT9043726 MAT9043727 MAT9049419 MAT9043732 MAT9043733 MAT9043734 MAT9043735 MAT9049467

3 3 3 3 3 4 4 4 4 4

3,0 5,0 7,0 10,0 15,0 3,0 5,0 7,0 10,0 15,0

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFINI (for up to 10 cuts of the same type) 4.281

Tel. +49-2203-96 49-0

1 BN

Fax +49-2203-96 49-222

Chainflex

BG

BW

CF.INI CF9

CF.INI
Chainflex Sensor/actuator cables with 5xd for Energy Chains Direct line M8 x 1: Socket with LED and free cable end
Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Number of poles Ampacity Rated voltage of a winding Insulation resistance Contact resistance Degree of soiling Operating voltage display Switching state display Switching function Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M 8 x 1 Plastic, TPU, transparent Metal, CuZn, nickel-plated Plastic, PA6GF, black Metal, CuZn, gold-plated Plastic, FPM (Viton) 3- p o l e 4A 10...30 V 10 9 5 m 3/2 LED green LED yellow pnp
3 BU

BWL
16,5 M8 x 1 9,6 28,3 23,5 LED

4 BK 1 BN

1+ GN

BN BK

-40 ... +105 C IP66K, in screwed state max. 100 insertion cycles

4 YE

BU

CF9.02.03.INI* (3 x 0.25) Type CF.INI-P3-M8-BWL2-3 CF.INI-P3-M8-BWL2-5 CF.INI-P3-M8-BWL2-7 CF.INI-P3-M8-BWL2-10 CF.INI-P3-M8-BWL2-15


* Technical information page 4.80

Part No. MAT9043720 MAT9043721 MAT9043722 MAT9043723 MAT90410196

Number of Cable length poles 3 3 3 3 3 [m] 3,0 5,0 7,0 10,0 15,0

Sensor/actuator cables

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.282

5x

CF.INI CF9

Connection cable M8 x 1: Socket, cable end with pin


Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Plug-type connector Handle base Union nut/screw Contact base Contacts Rated voltage of a winding Ampacity Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M8 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black 9,6 Metal, CuZn, gold-plated Plastic, FPM (Viton) Connector, M8 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated 3-pole: max. 60 V 4-pole: max. 30 V 4A 10 9 5 m 3/2
4 BK 3 BU 1 BN 1 BN
M8 x 1 M8 x 1

16,5 M8 x 1 9,5 28

9,6 34 41,2

4 BK 3 BU 3 BU

4 BK

4 BK 3 BU

2 WH 1 BN

2 WH 1 BN

4 BK 3 BU

4 BK 3 BU

2 WH 1 BN

-40 ... +105 C IP69K, in screwed state max. 100 insertion cycles

CF9.02.03.INI* (3 x 0.25) Type CF.INI-P3-M8-BG / M8-SG-2 CF.INI-P3-M8-BG / M8-SG-5 CF.INI-P3-M8-BG / M8-SG-10

Part No. MAT90410324 MAT90410325 MAT90410326

Number of Cable length poles 3 3 3 [m] 2,0 5,0 10,0

CF9.03.04.INI* (4 x 0.34) CF.INI-P4-M8-BG / M8-SG-2 CF.INI-P4-M8-BG / M8-SG-5 CF.INI-P4-M8-BG / M8-SG-10 MAT90410333 MAT90410334 MAT90410335 4 4 4 2,0 5,0 10,0

CF9.02.03.INI* (3 x 0.25) CF.INI-P3-M8-BW / M8-SG-2 CF.INI-P3-M8-BW / M8-SG-5 CF.INI-P3-M8-BW / M8-SG-10 MAT90410330 MAT90410331 MAT90410332 3 3 3 2,0 5,0 10,0

CF9.03.04.INI* (4 x 0.34) CF.INI-P4-M8-BW / M8-SG-2 CF.INI-P4-M8-BW / M8-SG-5 CF.INI-P4-M8-BW / M8-SG-10


* Technical information page 4.80

MAT90410336 MAT90410337 MAT90410338

4 4 4

2,0 5,0 10,0

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFINI (for up to 10 cuts of the same type) 4.283

Tel. +49-2203-96 49-0

1 BN

Fax +49-2203-96 49-222

Chainflex

BG

SG

BW

CF.INI CF10

CF.INI
Chainflex Sensor/actuator cables with 5xd for Energy Chains Direct line 360 shielded, M12 x 1: Socket with free cable end
Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Number of poles Ampacity Rated voltage of a winding Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M12 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton) 5- pole (4-pole + PE) 4A max. 60 V 10 9 5 m 3/2
1 BN

5x

BG
15

M12 x 1

BW
26,5

M12 x 1

42 10,2 11,6 12

15
8,8 11,6

31,5 12

2 WH 3 BU 4 BK 1 BN 5 GY

2 WH 3 BU 4 BK

-40 ... +105 C IP69K, in screwed state max. 100 insertion cycles

5 GY

brown white blue black green-yellow Shielded

CF10.03.05.INI* (5 x 0,34)C Type CF10.INI-P5-C-M12-BG-3 CF10.INI-P5-C-M12-BG-5 CF10.INI-P5-C-M12-BG-7 CF10.INI-P5-C-M12-BG-10 CF10.INI-P5-C-M12-BG-15

Part No. MAT90424072 MAT90424073 MAT90424074 MAT90424075 MAT90424076

Number of Cable length poles 5 5 5 5 5 [m] 3,0 5,0 7,0 10,0 15,0

CF10.03.05.INI* (5 x 0,34)C CF10.INI-P5-C-M12-BW-3 MAT90424077 MAT90424078 MAT90424079 MAT90424080 MAT90424081 5 5 5 5 5 3,0 5,0 7,0 10,0 15,0 CF10.INI-P5-C-M12-BW-5 CF10.INI-P5-C-M12-BW-7 CF10.INI-P5-C-M12-BW-10 CF10.INI-P5-C-M12-BW-15
* Technical information page 4.84

Sensor/actuator cables

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.284

CF.INI
Connection cable 360 shielded, M12 x 1: Socket, cable end with pin Plug-type connector Coupling, M12 x 1 BG
Handle base Union nut/screw Contact base Contacts Seal Number of poles Ampacity Rated voltage of a winding Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton) 5-pole (4-pole + PE) 4A max. 60 V 10 9 5 m 3/2
M12 x 1 15
M12 x 1 15

5x

CF.INI CF10

Chainflex Sensor/actuator cables with 5xd for Energy Chains

26,5

M12 x 1
52

42 10,2 11,6 12
10,2 11,6 12

15
8,8 11,6

31,5 12

2 WH 1 BN 5 GY 4 BK 3 BU 3 BU

2 WH 1 BN 1 BN 5 GY

2 WH

-40 ... +105 C IP69K, in screwed state max. 100 insertion cycles

5 GY 4 BK

4 BK

brown white blue black green-yellow Shielded

CF10.03.05.INI* (5 x 0,34)C Type CF10.INI-P5-C-M12-BG/M12-SG-2 CF10.INI-P5-C-M12-BG/M12-SG-5 CF10.INI-P5-C-M12-BG/M12-SG-10

Part No. MAT90424082 MAT90424083 MAT90424084

Number of Cable length poles 5 5 5 [m] 2,0 5,0 10,0

CF10.03.05.INI* (5 x 0,34)C CF10.INI-P5-C-M12-BW/M12-SG-2 CF10.INI-P5-C-M12-BW/M12-SG-5 CF10.INI-P5-C-M12-BW/M12-SG-10


* Technical information page 4.84

MAT90424085 MAT90424086 MAT90424087

5 5 5

2,0 5,0 10,0

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFINI (for up to 10 cuts of the same type) 4.285

Fax +49-2203-96 49-222

3 BU

Tel. +49-2203-96 49-0

Chainflex

SG

BW

CF.INI CF98

CF.INI
Chainflex Sensor/actuator cables with 4xd for Energy Chains Direct line M12 x 1: Socket with free cable end
Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Number of poles Ampacity Rated voltage of a winding Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M12 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton) 4- p o l e 4A max. 250 V 10 9 5 m 3/2
2 WH 2 WH 3 BU 4 BK 1 BN 4 BK 3 BU

BG
M12 x 1 15
M12 x 1

BW
26,5

42 10,2 11,6 12

15
8,8 11,6

31,5 12

-40 ... +105 C IP69K, in screwed state max. 100 insertion cycles

1 BN

CF98.03.04.INI* (4 x 0.34) Type CF98.INI-P4-M12-BG-3 CF98.INI-P4-M12-BG-5 CF98.INI-P4-M12-BG-7 CF98.INI-P4-M12-BG-10 CF98.INI-P4-M12-BG-15

Part No. MAT90410235 MAT90410236 MAT90410237 MAT90410238 MAT90410239

Number of Cable length poles 4 4 4 4 4 [m] 3,0 5,0 7,0 10,0 15,0

CF98.03.04.INI* (4 x 0.34) CF98.INI-P4-M12-BW-3 MAT90410240 MAT90410241 MAT90410242 MAT90410243 MAT90410244 4 4 4 4 4 3,0 5,0 7,0 10,0 15,0 CF98.INI-P4-M12-BW-5 CF98.INI-P4-M12-BW-7 CF98.INI-P4-M12-BW-10 CF98.INI-P4-M12-BW-15
* Technical information page 4.96

Sensor/actuator cables

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.286

4x

CF.INI CF98

Connection cable M12 x 1: Socket, cable end with pin


Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Plug-type connector Handle base Union nut/screw Contact base Contacts Rated voltage of a winding Ampacity Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M12 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, TPU, black Metal, CuZn, gold-plated Plastic, FPM (Viton) Connector, M12x1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, TPU, black Metal, CuZn, gold-plated 4-pole: max. 250V 4A 10 9 5 m 3/2
M12 x 1 M12 x 1
15

26,5

15

M12 x 1
42 10,2 11,6 12
10,2 11,6 12 52

15
8,8 11,6

31,5 12

2 WH 1 BN 4 BK 3 BU 3 BU

2 WH 1 BN 4 BK 1 BN

2 WH 3 BU 4 BK

-40 ... +105 C IP69K, in screwed state max. 100 insertion cycles

CF98.03.04.INI* (4 x 0.34) Type CF98.INI-P4-M12-BG / M12-SG-2 CF98.INI-P4-M12-BG / M12-SG-5

Part No. MAT90410300 MAT90410301

Number of Cable length poles 4 4 4 [m] 2,0 5,0 10,0

CF98.INI-P4-M12-BG / M12-SG-10 MAT90410302

CF98.03.04.INI* (4 x 0.34) CF98.INI-P4-M12-BW / M12-SG-2 CF98.INI-P4-M12-BW / M12-SG-5


* Technical information page 4.96

MAT90410303 MAT90410304

4 4 4

2,0 5,0 10,0

CF98.INI-P4-M12-BW / M12-SG-10 MAT90410305

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFINI (for up to 10 cuts of the same type) 4.287

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Chainflex

BG

SG

BW

CF.INI CF98

CF.INI
Chainflex Sensor/actuator cables with 4xd for Energy Chains Direct line M8 x 1: Socket with free cable end
Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Number of poles Ampacity Rated voltage of a winding Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M8 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated Plastic, FPM (Viton) 3- p o l e 4A max. 60 V 10 5 m 3/2
4 BK 4 BK 1 BN 3 BU 1 BN 3 BU
9

BG
M12 x 1 15

BW
16,5 16,5 M8M8 x 1 x1
42

9,59,5

28 28

10,2 11,6

12

-40 ... +105 C IP69K, in screwed state max. 100 insertion cycles

CF98.02.03.INI* (3 x 0.25) Type CF98.INI-P3-M8-BG-3 CF98.INI-P3-M8-BG-5 CF98.INI-P3-M8-BG-7 CF98.INI-P3-M8-BG-10 CF98.INI-P3-M8-BG-15

Part No. MAT90410245 MAT90410246 MAT90410247 MAT90410248 MAT90410249

Number of Cable length poles 3 3 3 3 3 [m] 3,0 5,0 7,0 10,0 15,0

CF98.02.03.INI* (3 x 0.25) CF98.INI-P3-M8-BW-3 MAT90410250 MAT90410251 MAT90410252 MAT90410253 MAT90410254 3 3 3 3 3 3,0 5,0 7,0 10,0 15,0 CF98.INI-P3-M8-BW-5 CF98.INI-P3-M8-BW-7 CF98.INI-P3-M8-BW-10 CF98.INI-P3-M8-BW-15
* Technical information page 4.96

Sensor/actuator cables

... no minimum order quantity


eplan download, configurator, PDF catalogues, lifetime ...

4.288

4x

CF.INI CF98

Connection cable M8 x 1: Socket, cable end with pin


Plug-type connector Handle base Union nut/screw Contact base Contacts Seal Plug-type connector Handle base Union nut/screw Contact base Contacts Rated voltage of a winding Ampacity Insulation resistance Contact resistance Degree of soiling Ambient temperature of plug-type connector Protection class Mechanical service life Coupling, M8 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, TPU, black 9,6 Metal, CuZn, gold-plated Plastic, FPM (Viton) Connector, M8 x 1 Plastic, PP, black Metal, CuZn, nickel-plated Plastic, PP, black Metal, CuZn, gold-plated 3-pole: max. 60 V 4A 10 9 5 m 3/2
4 BK 3 BU 1 BN 1 BN
M8 x 1 M8 x 1

16,5 M8 x 1 9,5 28

9,6 34 41,2

4 BK 3 BU 3 BU

4 BK 1 BN

-40 ... +105 C IP69K, in screwed state max. 100 insertion cycles

CF98.02.03.INI* (3 x 0.25) Type CF98.INI-P3-M8-BG / M8-SG-2 CF98.INI-P3-M8-BG / M8-SG-5 CF98.INI-P3-M8-BG / M8-SG-10

Part No. MAT90410306 MAT90410307 MAT90410308

Number of Cable length poles 3 3 3 [m] 2,0 5,0 10,0

CF98.02.03.INI* (3 x 0.25) CF98.INI-P3-M8-BW / M8-SG-2 CF98.INI-P3-M8-BW / M8-SG-5 CF98.INI-P3-M8-BW / M8-SG-10


* Technical information page 4.96

MAT90410309 MAT90410310 MAT90410311

3 3 3

2,0 5,0 10,0

950 types from stock no cutting costs ...


... and order online www.igus.eu/en/CFINI (for up to 10 cuts of the same type) 4.289

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Chainflex

BG

SG

BW

4.290

Drive technology

4.291

Content

Chainflex ReadyCable
Selection table according to systems (Part No. and sheath materials)

Jacket

Page

Cables for Drive Technology NEW* NEW* NEW* NEW* NEW* NEW* NEW* NEW* B&R Baumller Beckhoff Berger Lahr Control Techniques Danaher Motion ELAU Fagor Fanuc NEW* Heidenhain Lenze NEW* NUM Rexroth SEW Siemens NEW* Stber
igus.eu/en/CFBR igus.eu/en/CFBAUMUELLER igus.eu/en/CFBECKHOFF igus.eu/en/CFBERGERLAHR igus.eu/en/CFCONTROLTECHNIQUES igus.eu/en/CFDANAHER igus.eu/en/CFELAU igus.eu/en/CFFAGOR igus.eu/en/CFFANUC igus.eu/en/CFHEIDENHAIN igus.eu/en/CFLENZE igus.eu/en/CFNUM igus.eu/en/CFREXROTH igus.eu/en/CFSEW igus.eu/en/CFSIEMENS igus.eu/en/CFSTOEBER PVC/PUR/TPE 4.294 PVC/PUR/TPE 4.294 PVC/PUR/TPE 4.296 PVC/PUR/TPE 4.296 PVC/PUR/TPE 4.297 PVC/PUR/TPE 4.298 PVC/PUR/TPE 4.300 TPE PUR/TPE PUR/TPE 4.301 4.301 4.301

PVC/PUR/TPE 4.302 PVC/PUR/TPE 4.303 PVC/PUR/TPE 4.303 PVC/PUR/TPE 4.305 PVC/PUR/TPE 4.306 PVC/PUR/TPE 4.307

To make the choice easier for you, we have classified all Chainflex-cables according to the criteria "requirements, oil-resistance and travel distance". For this reason we have extended the Technical specifications by the specification Class 6.3.3, for example. For detailed information see the inside of the front cover flap.

4.292

* New in this catalog.

Chainflex ReadyCable
Cables for Drive Technology

Chainflex PVC cables for the woodworking industry, for example


Typical application area PVC
n for high load requirements n light oil influence n preferably indoor applications, but also outdoor ones at temperatures > 5 C n especially for freely suspended and gliding travel distances up to 100 m n Storage and retrieval units for high-bay warehouses, machining units/packaging machines, quick handling, indoor cranes, timber processing

Chainflex PUR cables for the tooling machine industry, for example
Typical application area PUR
n n n n for maximum load requirements almost unlimited resistance to oil Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 100 m n Storage and retrieval units for high-bay warehouses, machining units/machine tools, quick handling, clean room, semiconductor insertion, outdoor cranes, low-temperature applications

Chainflex TPE cables for outdoor use, for example


Typical application area TPE
n n n n for maximum load requirements almost unlimited resistance to oil, also with bio-oils Indoor and outdoor applications, UV-resistant especially for freely suspended and gliding travel distances up to 400 m and more n Storage and retrieval units for high-bay warehouses, machining units/ machine tools, quick handling, clean room, semiconductor insertion, ship to shore, outdoor cranes, low-temperature applications

Our product engineers will be happy to advise you in your choice of application-specific cables.
4.293

Content

Chainflex ReadyCable
B&R Selection table according to part numbers and sheath materials.
Connection cable Outer jacket material page TPE PVC i8CMxxx.12-1 i8CMxxx.12-3 i8CMxxx.12-5 i8CRxxx.12-1 i8CExxx.12-1 4.308 4.308 4.308 4.356 4.360 PUR 4.326 4.326 4.326 4.378 4.380 Extension cable

Outer jacket material PVC PUR

page TPE

B&R

Baumller Selection table according to part numbers and sheath materials.


You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC 198962 (3 m) 198963 (5 m) 198964 (8 m) 198965 (10 m) 198966 (15 m) 198967 (10 m) 198968 (25 m) 198969 (30 m) 208829 (40 m) 225360 (35 m) 239540 (5 m) 239541 (8 m) 239542 (10 m) 239543 (15 m) 239544 (20m) 239545 (25 m) 239546 (30 m) 239547 (35 m) 240520 (40 m) 240521 (45 m) 240522 (50 m) 242954 (6 m) 243379 (4 m) 244033 (55 m) 245484 (60 m) 246658 (3 m) 324781 (5 m) 324782 (7 m) 324783 (10 m) 324784 (15 m) 324785 (20m) 324786 (25 m) 324787 (30 m) 324788 (35 m) 324789 (40 m) 324790 (50 m) 324791 (75 m) 4.360 4.360 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.326 4.326 4.326 4.326 4.326 4.326 4.326 4.326 4.326 4.326 4.326 PUR page TPE 4.380 4.380 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 Pulse encoder Pulse encoder Pulse encoder Pulse encoder Pulse encoder Pulse encoder Pulse encoder Pulse encoder Pulse encoder Pulse encoder Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Resolver / SKS / SKM Servo cable 15A Servo cable 15A Servo cable 15A Servo cable 15A Servo cable 15A Servo cable 15A Servo cable 15A Servo cable 15A Servo cable 15A Servo cable 15A Servo cable 15A Extension cable Outer jacket material PVC 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.360 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.308 4.326 4.326 4.326 4.326 4.326 4.326 4.326 4.326 4.326 4.326 4.326 PUR page TPE 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380 4.380

4.294

BAUMLLER

Content

Chainflex ReadyCable
Baumller Selection table according to part numbers and sheath materials.
You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC 324792 (100 m) 326577 (5 m) 326578 (7 m) 326579 (10 m) 326580 (15 m) 326581 (20 m) 326582 (25 m) 326583 (30 m) 326584 (35 m) 326585 (40 m) 326586 (50 m) 326587 (70 m) 326588 (100 m) 326589 (5 m) 326591 (7 m) 326592 (10 m) 326593 (15 m) 326594 (20 m) 4.308 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.361 4.361 4.361 4.361 4.309 4.361 4.327 4.381 PUR 4.326 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.381 4.381 4.381 4.381 page TPE Servo cable 15A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 21 A Servo cable 28 A Servo cable 28 A Servo cable 28 A Servo cable 28 A Servo cable 28 A Servo cable 28 A Servo cable 28 A Servo cable 28 A Servo cable 28 A Servo cable 36 A Servo cable 36 A Servo cable 36 A Servo cable 36 A Servo cable 36 A Servo cable 36 A Servo cable 36 A Servo cable 36 A Servo cable 36 A Servo cable 50 A Servo cable 50 A Servo cable 50 A Servo cable 50 A Servo cable 50 A Servo cable 50 A Servo cable 50 A Servo cable 50 A Servo cable 50 A ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 Servo cable 20 A ECN1313/EQN1325 Extension cable

Outer jacket material PVC 4.308 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.310 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.311 4.362 4.362 4.362 4.362 4.309 4.362 4.327 PUR 4.326 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.328 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329 4.329

page TPE

BAUMLLER

326596 (25 m) 326597 (30 m) 326598 (35 m) 326599 (40 m) 326600 (5 m) 326601 (7 m) 326602 (10 m) 326603 (15 m) 326604 (20 m) 326605 (25 m) 326606 (30 m) 326607 (35 m) 326608 (40 m) 326609 (5 m) 326610 (7 m) 326611 (10 m) 326612 (15 m) 326613 (20 m) 326614 (25 m) 326615 (30 m) 326616 (35 m) 326617 (40 m) 369864 (3 m) 371494 (20 m) 378022 (50 m) 380358 (35 m) 380967 (7 m) 382005 (45 m)

4.382 4.382 4.382 4.382 4.382

4.295

Content

Chainflex ReadyCable
Baumller Selection table according to part numbers and sheath materials.
You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC 389807 (7 m) 389808 (9 m) 391216 (40 m) 393889 (2 m) 393890 (8 m) 393891 (10 m) 393892 (15 m) 393893 (25 m) 393894 (30 m) 394014 (5 m) 413410 (10 m) 414840 (5 m) 414841 (15 m) 414842 (20 m) 414843 (25 m) 414846 (30 m) 414848 (35 m) 414849 (40 m) 414850 (50 m) 414851 (75 m) 414852 (100 m) 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.361 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 PUR page TPE 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.381 4.381 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 ECN1313/EQN1325 Servo cable 20 A Servo cable 20 A Servo cable 20 A Servo cable 20 A Servo cable 20 A Servo cable 20 A Servo cable 20 A Servo cable 20 A Servo cable 20 A Servo cable 20 A Servo cable 20 A Extension cable PVC 4.362 4.362 4.362 4.362 4.362 4.362 4.362 4.362 4.362 4.362 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 4.309 PUR

Outer jacket material

page TPE 4.382 4.382 4.382 4.382 4.382 4.382 4.382 4.382 4.382 4.382

BAUMLLER

4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327 4.327

Beckhoff Selection table according to part numbers and sheath materials.


You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC PUR 4.329 4.329 4.372 4.372 4.330 4.330 4.372 4.372 4.372 ZK4501-0023-xxxx ZK4501-0024-xxxx ZK4511-0020-xxxx ZK4511-0020-xxxx ZK4531-0020-xxxx Extension cable Outer jacket material PVC VW3M5101Rxxx VW3M5102Rxxx VW3M8101Rxxx 4.312 4.312 4.362 PUR 4.330 4.330 4.382 page TPE Outer jacket material PVC PUR page TPE 4.312 4.312 4.356 4.356 4.357 4.330 4.330 4.372 4.372 4.372 page TPE 4.396 4.311 4.311 4.356 4.356 4.312 4.312 4.356 4.356 4.356 Extension cable Outer jacket material PVC PUR page TPE

BECKHOFF 4.296 BERGER LAHR

ZK1090-9191-xxxx ZK4000-2111-xxxx ZK4000-2112-xxxx ZK4000-2210-xxxx ZK4000-2610-xxxx ZK4500-0023-xxxx ZK4500-0024-xxxx ZK4510-0020-xxxx ZK4520-0020-xxxx ZK4530-0010-xxxx Basic cable

Berger Lahr Selection table according to part numbers and sheath materials.

Content

Chainflex ReadyCable
Control Techniques Selection table according to part numbers and sheath materials.
Basic cable Outer jacket material PVC PB B A A A XXX PB B A A B XXX PB B A B B XXX PB B A F A XXX PB B A F B XXX PB B A G B XXX PB B B A A XXX PB B B A B XXX PB B B F A XXX PB B B G B XXX PB B C A B XXX PB B C B B XXX PB B C F B XXX PB B C G B XXX PB B D A B XXX PB B D B B XXX PB B D F B XXX 4.312 4.313 4.313 4.312 4.313 4.313 4.312 4.313 4.312 4.313 4.313 4.313 4.313 4.313 4.313 4.313 4.313 4.313 4.313 4.313 4.312 4.313 4.313 4.312 4.313 4.313 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 4.344 PUR 4.330 4.331 4.331 4.330 4.331 4.331 4.330 4.331 4.330 4.331 4.331 4.331 4.331 4.331 4.331 4.331 4.331 4.331 4.331 4.331 4.330 4.331 4.331 4.330 4.331 4.331 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 4.350 page TPE Extension cable

Outer jacket material PVC PUR

page TPE

CONTROL TECHNIQUES

PB B D G B XXX PB B E A B XXX PB B E B B XXX PB B G A A XXX PB B G A B XXX PB B G B B XXX PB B G F A XXX PB B G F B XXX PB B G G B XXX PS B A A A XXX PS B A A B XXX PS B A B B XXX PS B A F A XXX PS B A F B XXX PS B B A A XXX PS B B A B XXX PS B B B B XXX PS B B F A XXX PS B C A B XXX PS B C B B XXX PS B C F B XXX PS B D A B XXX PS B D B B XXX PS B D F B XXX PS B E A B XXX PS B E B B XXX PS B G A A XXX PS B G A B XXX PS B G B B XXX PS B G F A XXX

4.297

Content

Chainflex ReadyCable
Control Techniques Selection table according to part numbers and sheath materials.
Basic cable Outer jacket material PVC PUR page TPE 4.350 4.382 4.382 4.382 4.331 4.331 4.313 4.313 4.344 4.344 4.331 4.331 4.350 4.350 Extension cable Outer jacket material PVC 102575 (5 m) 102576 (10 m) 102579 (5 m) 102580 (10 m) 102806 (15 m) 102807 (20 m) 102808 (25 m) 102809 (15 m) 102810 (20 m) 102811 (25 m) 107473 (5 m) 107474 (10 m) 107475 (15 m) 107476 (20 m) 107477 (25 m) 107479 (5 m) 107480 (10 m) 107481 (15 m) 107482 (20 m) 107483 (25 m) 107485 (5 m) 107486 (10 m) 107487 (15 m) 107488 (20 m) 107489 (25 m) 107491 (5 m) 107492 (10 m) 107493 (15 m) 107494 (20 m) 107495 (25 m) 107915 (5 m) 107916 (10 m) 4.345 4.345 4.314 4.314 4.345 4.345 4.345 4.314 4.314 4.314 4.345 4.345 4.345 4.345 4.345 4.314 4.314 4.314 4.314 4.314 4.345 4.345 4.345 4.345 4.345 4.313 4.313 4.313 4.313 4.314 4.357 4.357 4.331 4.331 4.331 4.331 4.332 4.378 4.378 4.332 4.332 4.332 4.332 4.332 4.351 4.351 4.351 4.351 4.351 4.332 4.332 4.332 4.351 4.351 4.351 4.351 4.351 4.332 4.332 4.351 4.351 4.351 PUR page TPE 4.351 4.351 Extension cable PVC PUR

Outer jacket material

page TPE

CONTROL TECHN.

PS B G F B XXX SS B A H C XXX SS B A H H XXX SS B A H N XXX PB A A F B XXX PB B B B B XXX PB B B F B XXX PB B E F B XXX PB B E G B XXX PS B B F B XXX PS B E F B XXX Connection cable

4.344 4.362 4.362 4.362 4.313 4.313

Danaher Motion Selection table according to part numbers and sheath materials.
Outer jacket material PVC PUR page TPE

4.298

DANAHER MOTION

Content

Chainflex ReadyCable
Danaher Motion Selection table according to part numbers and sheath materials.
Connection cable Outer jacket material PVC 107917 (15 m) 107918 (20 m) 107919 (25 m) 200456 (5 m) 200457 (10 m) 200458 (15 m) 200459 (20 m) 200460 (25 m) 200462 (5 m) 200463 (10 m) 200464 (15 m) 200465 (20 m) 200466 (25 m) 200468 (5 m) 200469 (10 m) 200470 (15 m) 200471 (20 m) 200472 (25 m) 4.357 4.357 4.357 4.346 4.346 4.346 4.346 4.346 4.314 4.314 4.314 4.314 4.314 4.346 4.346 4.346 4.346 4.346 4.314 4.315 4.315 4.315 4.315 4.346 4.346 4.346 4.346 4.346 4.315 4.315 4.315 4.315 4.315 4.357 4.357 4.357 4.357 4.357 4.357 4.357 4.357 4.358 4.358 4.358 4.358 4.357 4.345 4.333 4.333 4.333 4.333 4.333 4.378 4.378 4.378 4.378 4.378 4.378 4.378 4.378 4.379 4.379 4.379 4.379 4.378 4.351 4.332 4.333 4.333 4.333 4.333 4.352 4.352 4.352 4.352 4.352 4.332 4.332 4.332 4.332 4.332 4.352 4.352 4.352 4.352 4.352 PUR page TPE 4.378 4.378 4.378 4.352 4.352 4.352 4.352 4.352 Extension cable

Outer jacket material PVC PUR

page TPE

DANAHER MOTION

200474 (5 m) 200475 (10 m) 200476 (15 m) 200477 (20 m) 200478 (25 m) 200618 (5 m) 200619 (10 m) 200620 (15 m) 200621 (20 m) 200622 (25 m) 200623 (5 m) 200624 (10 m) 200625 (15 m) 200626 (20 m) 200627 (25 m) 84972 (5 m) 84973 (10 m) 84974 (15 m) 84975 (20 m) 85034 (5 m) 85035 (10 m) 85036 (15 m) 85037 (20 m) 85039 (5 m) 85040 (10 m) 85041 (15 m) 85042 (20 m) 87655 (25 m) 89918 (5 m)

4.299

Content

Chainflex ReadyCable
Danaher Motion Selection table according to part numbers and sheath materials.
Connection cable Outer jacket material PVC 89952 (10 m) 89953 (15 m) 89954 (20 m) 89956 (25 m) 89957 (5 m) 89959 (5 m) 89960 (10 m) 89961 (10 m) 89962 (15 m) 89963 (15 m) 89964 (20 m) 4.345 4.345 4.345 4.345 4.314 4.345 4.345 4.314 4.345 4.314 4.346 4.314 4.346 4.314 4.314 4.314 4.314 4.314 4.314 4.345 4.345 4.345 4.345 4.345 4.314 4.314 4.314 4.314 4.314 4.357 4.357 4.357 4.357 4.357 4.332 4.332 4.332 4.332 4.332 4.378 4.378 4.378 4.378 4.378 Extension cable Outer jacket material PVC E-MO-067 4.315 4.315 4.315 4.315 4.315 4.362 4.362 4.362 PUR 4.333 4.333 4.333 4.333 4.333 4.382 4.382 4.382 page TPE 4.332 4.332 4.332 4.332 4.332 4.332 4.351 4.351 4.351 4.351 4.351 4.332 4.352 4.332 4.352 4.332 4.351 4.332 4.351 4.351 PUR page TPE 4.351 4.351 4.351 4.351 Extension cable PVC PUR

Outer jacket material

page TPE

DANAHER MOTION

89965 (20 m) 89966 (25 m) 89967 (25 m) 89968 (5 m) 89969 (25 m) 89970 (10 m) 89971 (15 m) 89972 (20 m) 90083 (5 m) 90084 (10 m) 90085 (15 m) 90086 (20 m) 90087 (25 m) 90088 (5 m) 90089 (10 m) 90090 (15 m) 90091 (20 m) 90092 (25 m) 90287 (5 m) 91019 (10 m) 91807 (20 m) 91811 (15 m) 92205 (25 m) Connection cable

Elau Selection table according to part numbers and sheath materials.


Outer jacket material PVC PUR page TPE

ELAU 4.300

E-MO-111 SH-Motor 1,5 E-MO-087 E-MO-092 E-MO-113 SH-Motor 2.5 E-FB-060 E-FB-071 E-FB-080

Content

Chainflex ReadyCable
Fagor Selection table according to part numbers and sheath materials.
Basic cable Outer jacket material PVC PUR page TPE 4.382 4.383 4.383 4.383 4.383 4.383 4.383 Extension cable

Outer jacket material PVC PUR

page TPE

FAGOR

iXC-C2-D iXC-C2-FN2 iXC-C2-H iXC-C4-D iXC-C8-F-C9 iXC-C8-F-D iXC-C8-FN

FANUC Selection table according to part numbers and sheath materials.


You will find your basic cable in the left column, the respective extension on the right. Basic cable Premium Line Outer jacket material PVC LX660-4077-T296 LX660-4077-T297 LX660-4077-T302 LX660-4077-T303 LX660-4077-T319 LX660-8077-T261 PUR 4.374 4.374 4.374 4.374 4.374 4.324 4.324 4.324 4.324 4.324 4.324 4.324 4.324 4.324 4.324 4.325 4.324 4.325 4.325 4.325 page TPE LX660-4077-T296 LX660-4077-T297 LX660-4077-T302 LX660-4077-T303 LX660-4077-T319 LX660-8077-T261 LX660-8077-T264 LX660-8077-T265 LX660-8077-T266 LX660-8077-T267 LX660-8077-T270 LX660-8077-T271 LX660-8077-T272 LX660-8077-T273 LX660-8077-T291 LX660-8077-T292 LX660-8077-T293 LX660-8077-T296 LX660-8077-T298 LX660-8077-T300 Extension cable Outer jacket material PVC 298 399-xx PUR 4.375 4.375 4.376 4.375 4.375 4.376 4.376 4.376 4.375 4.375 4.375 page TPE 4.385 4.385 4.386 4.385 4.385 4.385 4.385 4.386 4.384 4.385 4.385 Outer jacket material PVC PUR page TPE 4.333 4.334 4.334 4.334 4.334 4.334 4.334 4.334 4.334 4.334 4.334 4.334 4.335 4.335 4.335 Basic cable Economy Line Outer jacket material PVC PUR page TPE 4.383 4.384 4.384 4.384 4.384

FANUC HEIDENHAIN

LX660-8077-T264 LX660-8077-T265 LX660-8077-T266 LX660-8077-T267 LX660-8077-T270 LX660-8077-T271 LX660-8077-T272 LX660-8077-T273 LX660-8077-T291 LX660-8077-T292 LX660-8077-T293 LX660-8077-T296 LX660-8077-T298 LX660-8077-T300 Connection cable

Heidenhain Selection table according to part numbers and sheath materials.

298 400-xx 298 402-xx 309 738-xx 309 774-xx 309 777-xx 309 778-xx 310 193-xx 310 197-xx 310 199-xx 323 897-xx

4.301

Content

Chainflex ReadyCable
Heidenhain Selection table according to part numbers and sheath materials.
Connection cable Extension cable Outer jacket material PVC 324 544-xx 332 115-xx 335 077-xx 354 411-xx 355 398-xx 360 472-xx PUR 4.375 4.374 4.376 4.375 4.375 4.374 page TPE 4.385 4.384 4.386 4.385 4.385 4.384

HEIDENHAIN

Outer jacket material PVC PUR

page TPE

Lenze Selection table according to part numbers and sheath materials.


You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC EWLExxxGM-T EWLLxxxGMS EWLMxxxGMS-015C EWLMxxxGMS-025 EWLRxxxGM-T EYF0018AxxxxA00S03 EYF0018AxxxxA00W02 EYF0018AxxxxF02S03 EYF0018AxxxxF02W02 EYF0019VxxxxA00G02 EYF0020AxxxxA00S04 EYF0020AxxxxA00S05 EYF0020AxxxxF01S04 EYF0020AxxxxF01S05 4.363 4.400 4.315 4.315 4.362 4.364 4.364 4.364 4.364 4.363 4.364 4.364 4.364 4.364 4.363 4.364 4.364 4.363 4.400 4.400 4.400 4.400 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.335 4.335 4.335 4.335 4.336 4.335 4.335 4.335 4.335 4.335 4.335 4.335 4.335 4.335 4.335 4.335 4.386 4.388 4.387 4.387 4.387 4.387 4.387 4.388 4.387 4.387 4.387 4.388 4.387 4.387 4.402 4.402 4.402 4.402 EYF0022VxxxxF03G03 EYF0022VxxxxF03G03 EYL002VxxxxL01J01 EYL002VxxxxL02J02 EYL002VxxxxL01J01 EYL002VxxxxL02J02 EYP0010VxxxxM01P01 EYP0010VxxxxM01P01 EYP0011VxxxxM01P01 EYP0011VxxxxM01P01 EYP0012VxxxxM01P01 EYP0012VxxxxM02P02 EYP0012VxxxxM01P01 EYP0012VxxxxM02P02 EYP0013VxxxxM02P02 EYP0013VxxxxM02P02 EYP0014VxxxxM03P03 EYP0014VxxxxM03P03 EYP0015VxxxxM03P03 EYP0015VxxxxM03P03 4.364 4.364 4.400 4.400 4.400 4.400 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.316 4.336 4.336 4.336 4.336 4.336 4.336 4.336 4.336 4.336 4.336 4.336 4.336 4.336 4.336 4.388 4.388 4.402 4.402 4.402 4.402 EYF0020VxxxxF01G01 EYF0020VxxxxF01G01 EYF0020VxxxxF01G01 4.364 4.364 4.364 4.388 4.388 4.388 EYF0019VxxxxF02G02 EYF0019VxxxxF02G02 EYF0019VxxxxF02G02 4.364 4.364 4.364 4.388 4.388 4.388 PUR page TPE 4.386 4.402 EWLExxxZMST EWLLxxxZM EWLMxxxZM-015C EWLMxxxZM-025 EWLRxxxZMST Linking cable Outer jacket material PVC 4.363 4.400 4.316 4.316 4.363 4.336 4.336 4.386 PUR page TPE 4.387 4.402

LENZE 4.302

EYF0020VxxxxA00G01 EYF0021AxxxxA00S03 EYF0021AxxxxF03S03 EYF0022VxxxxA00G03 EYL002AxxxxL01A00 EYL002AxxxxL02A00 EYL002VxxxxA00J01 EYL002VxxxxA00J02 EYP0010AxxxxA00P01 EYP0010AxxxxM01A00 EYP0011AxxxxA00P01 EYP0011AxxxxM01A00 EYP0012AxxxxA00P01 EYP0012AxxxxA00P02 EYP0012AxxxxM01A00 EYP0012AxxxxM02A00 EYP0013AxxxxA00P02 EYP0013AxxxxM02A00 EYP0014AxxxxA00P03 EYP0014AxxxxM03A00 EYP0015AxxxxA00P03 EYP0015AxxxxM03A00

Content

Chainflex ReadyCable
Lenze Selection table according to part numbers and sheath materials.
You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC EYP0016AxxxxA00P03 4.316 4.316 4.363 4.363 4.365 4.365 4.365 4.365 PUR 4.335 4.335 4.387 4.386 4.388 4.388 4.388 4.388 page TPE EYP0016VxxxxM03P03 EYP0016VxxxxM03P03 Linking cable

Outer jacket material PVC 4.316 4.316 PUR 4.336 4.336

page TPE

LENZE

EYP0016AxxxxM03A00 Terminal box connection cable EWLExxxGX-T EWLRxxxGX-T Connecting cable EYD0017AxxxxW01S01 EYD0017AxxxxW01S02 EYD0017AxxxxW03S01 EYD0017AxxxxW03S02

NUM Selection table according to part numbers and sheath materials.


You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC PUR page TPE 4.402 4.352 4.336 4.352 4.336 4.336 4.389 4.389 AGOFRU012Mxxx AGOFRU018LMxxx AGOFRU018Mxxx AGOFRU019LMxxx AGOFRU019Mxxx AGOFRU020Mxxx AGOFRU029Mxxx AGOFRU030Mxxx Extension cable Outer jacket material PVC 4.398 4.346 4.317 4.346 4.317 4.317 4.365 4.366 4.336 4.337 4.389 4.389 4.336 4.352 PUR page TPE 4.402 4.352

NUM

AGOFRU012Mxxx AGOFRU018LMxxx AGOFRU018Mxxx AGOFRU019LMxxx AGOFRU019Mxxx AGOFRU020Mxxx AGOFRU029Mxxx AGOFRU030Mxxx

4.398 4.346 4.316 4.346 4.316 4.317 4.365 4.365

Rexroth Selection table according to part numbers and sheath materials.


You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC IKG0001 IKG0006 IKG0011 IKG0021 IKG0041 IKG0042 IKG0061 IKG0081 IKG0101 IKG0121 IKG0161 IKG0331 IKG4008 IKG4009 IKG4017 IKG4018 IKG4020 IKG4055 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.317 4.318 4.318 PUR 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 IKG0168 IKG0332 IKG4006 IKG4006 IKG4006 4.318 4.318 4.318 4.318 4.318 4.338 4.338 4.338 4.338 4.338 IKG0089 4.318 4.338 IKG0023 4.318 4.338 page TPE Connecting cable with adapter plugs Outer jacket material PVC PUR page TPE

REXROTH

4.303

Content

Chainflex ReadyCable
Rexroth Selection table according to part numbers and sheath materials.
You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC IKG4060 IKG4067 IKG4070 IKG4072 IKG4087 IKG4090 IKG4100 IKG4103 IKG4107 IKG4118 IKG4119 IKG4147 IKG4150 IKG4155 IKG4164 IKG4167 IKG4172 IKG4173 IKG4186 IKG4200 IKG4204 IKS0230 IKS0251 IKS0253 IKS0259 IKS0262 IKS0301 IKS0315 IKS0374 IKS4001 IKS4002 IKS4020 IKS4038 IKS4041 IKS4042 IKS4066 IKS4103 IKS4142 IKS4314 IKS4374 IKS4375 IKS4384 IKS4389 RKG0014 RKG0020 RKG0026 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.366 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.318 4.366 PUR 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.337 4.338 4.338 4.338 4.338 4.338 4.338 4.338 4.338 4.338 4.338 4.338 4.338 4.389 4.389 4.389 4.389 4.389 4.389 4.389 4.389 4.389 4.389 4.389 4.389 4.390 4.390 4.390 4.390 4.390 4.390 4.390 4.390 4.390 4.390 4.390 4.390 4.390 IKS4322 IKS4376 4.367 4.367 IKS4151 / IKS 4153 4.367 IKS4376 4.367 IKS0303 4.367 IKS0232 IKS0255 IKS0255 4.366 IKG4161 4.319 IKG4141 IKG4141 IKG4141 4.319 4.319 4.319 IKG4061 IKG4061 IKG4074 IKG4081 IKG4081 4.318 4.318 4.318 4.318 4.318 page TPE Connecting cable with adapter plugs PVC PUR

Outer jacket material

page TPE

4.338 4.338 4.338 4.338 4.338

4.338 4.338 4.338 4.338

REXROTH

4.390 4.390 4.390

4.390

4.390

4.390 4.390 4.390

4.304

Content

Chainflex ReadyCable
Rexroth Selection table according to part numbers and sheath materials.
You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC RKG0028 RKG4200 RKL4300 RKL4301 RKL4302 RKL4303 RKL4306 RKL4307 RKL4308 RKL4309 RKL4310 RKL4313 RKL4314 RKL4315 RKL4317 RKL4318 RKL4320 RKL4321 RKL4322 RKL4323 RKL4324 RKL4325 RKL4326 RKL4327 RKL4328 RKL4329 RKL4330 RKL4331 4.366 4.367 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.319 4.338 4.338 4.338 4.338 4.338 4.338 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 RKL4340 RKL4336 RKL4338 RKL4338 RKL4336 PUR page TPE 4.390 4.390 RKG4201 RKL4304 RKL4304 RKL4305 RKL4305 RKL4311 RKL4311 RKL4312 RKL4312 RKL4312 RKL4316 RKL4316 RKL4316 RKL4319 RKL4319

Connecting cable with adapter plugs Outer jacket material PVC 4.367 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.320 4.339 4.339 PUR page TPE 4.390 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339 4.339

REXROTH

4.320 4.320 4.320

4.339 4.339 4.339

SEW Selection table according to part numbers and sheath materials.


You will find your basic cable in the left column, the respective extension on the right. Connection cable Outer jacket material PVC 0590 477 3 1332 455 1 1332 486 1 4.347 4.367 4.320 4.367 4.367 4.346 4.346 4.346 4.347 4.347 4.320 4.320 4.320 4.340 4.340 4.340 4.340 4.391 4.391 4.352 4.352 4.352 4.353 4.353 199 550 2 199 552 9 199 554 5 199 556 1 199 558 8 199 200 7 199 202 3 199 204 X 4.347 4.347 4.347 4.391 4.347 4.320 4.320 4.320 4.340 4.340 4.340 4.353 4.353 4.353 4.353 4.353 PUR page TPE 4.353 4.391 0590 361 0 199 540 5 0593 650 0 199 541 3 Extension cable Outer jacket material PVC 4.347 4.367 4.321 4.367 4.340 4.391 PUR page TPE 4.353 4.391

SEW

1332 743 7 198 930 8 199 180 9 199 182 5 199 184 1 199 186 8 199 188 4 199 190 6 199 192 2 199 194 9

4.305

Content

Chainflex ReadyCable
SEW Selection table according to part numbers and sheath materials.
You will find your basic cable in the left column, the respective extension on the right. Connection cable Extension cable Outer jacket material PVC 199 196 5 199 198 1 199 319 4 4.320 4.320 4.367 PUR 4.340 4.340 4.391 page TPE 199 206 6 199 208 2 199 541 3

SEW

Outer jacket material PVC 4.320 4.320 4.367 PUR 4.340 4.340

page TPE

4.391

Siemens Selection table according to part numbers and sheath materials.


You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material PVC 6FX8002-1DC00 6FX8002-2AD00 6FX8002-2AH00 6FX8002-2CA11 6FX8002-2CA15 6FX8002-2CA31 6FX8002-2CA51 6FX8002-2CA71 6FX8002-2CB31 6FX8002-2CB51 6FX8002-2CC11 6FX8002-2CD01 6FX8002-2CF01 6FX8002-2CF02 6FX8002-2CG00 6FX8002-2CH00 6FX8002-2CK00 6FX8002-2CL00 6FX8002-2DC10 6FX8002-2DC20 6FX8002-2EQ00 6FX8002-2EQ10 6FX8002-5CA01 6FX8002-5CA11 6FX8002-5CA21 6FX8002-5CA23 6FX8002-5CA31 6FX8002-5CA41 6FX8002-5CA51 6FX8002-5CA61 6FX8002-5CS01 6FX8002-5CS21 6FX8002-5CS31 6FX8002-5DA01 6FX8002-5DA11 6FX8002-5DA21 6FX8002-5DA23 6FX8002-5DA31 4.369 4.369 4.347 4.347 4.347 4.348 4.347 4.347 4.347 4.347 4.348 4.348 4.348 4.321 4.321 4.321 4.321 4.321 4.340 4.340 4.341 4.341 4.341 4.368 4.368 4.368 4.368 4.368 4.368 4.368 4.368 4.368 4.368 4.369 4.368 4.368 4.368 4.368 4.368 PUR page TPE 4.376 4.391 4.393 4.391 4.391 4.391 4.391 4.391 4.392 4.392 4.392 4.392 4.392 4.392 4.392 4.392 4.392 4.392 4.376 4.376 4.392 4.392 4.353 4.353 4.353 4.354 4.353 4.353 4.353 4.353 4.354 4.354 4.354 6FX8002-5DA05 6FX8002-5DA15 6FX8002-5DA28 6FX8002-5DX28 6FX8002-5DA38 4.322 4.322 4.322 4.322 4.322 4.341 4.341 4.341 4.342 4.341 6FX8002-2EQ14 6FX8002-5CA05 6FX8002-5CA15 6FX8002-5CA28 6FX8002-5CX28 6FX8002-5CA38 6FX8002-5CA48 6FX8002-5CA58 6FX8002-5CA68 4.369 4.348 4.348 4.348 4.348 4.348 4.348 4.348 4.348 4.393 4.354 4.354 4.354 4.354 4.354 4.354 4.354 4.354 6FX8002-2CF04 6FX8002-2CB54 6FX8002-2AD04 4.369 4.369 4.369 4.393 4.393 4.393 6FX8002-2CB34 6FX8002-2CC14 6FX8002-2CB54 6FX8002-2CB54 4.369 4.369 4.369 4.393 4.393 4.393 4.393 6FX8002-2AD04 6FX8002-2AH04 6FX8002-2CB54 6FX8002-2CA54 6FX8002-2CA34 6FX8002-2CA54 4.369 4.369 4.369 4.369 4.369 4.369 4.393 4.393 4.393 4.393 4.393 4.393 Extension cable Outer jacket material PVC PUR page TPE

4.306

SIEMENS

Content

Chainflex ReadyCable
Siemens Selection table according to part numbers and sheath materials.
You will find your basic cable in the left column, the respective extension on the right. Basic cable Outer jacket material page TPE 6FX8002-5DX38 6FX8002-5DA48 6FX8002-5DX48 6FX8002-5DA58 6FX8002-5DA68 PVC 6FX8002-5DA33 6FX8002-5DA41 6FX8002-5DA43 6FX8002-5DA51 6FX8002-5DA61 6FX8002-5DS01 6FX8002-5DS21 6FX8002-5DS61 Basic cable Outer jacket material PVC Gr.1-Motor-1,0mm Gr.1-Motor-1,5mm 4.322 4.322 4.322 4.322 4.322 4.322 4.323 4.370 4.370 4.369 4.370 PUR 4.342 4.342 4.342 4.342 4.342 4.342 4.342 4.394 4.394 4.393 4.393 4.394 page TPE 4.321 4.321 4.321 4.321 4.321 4.321 4.321 4.321 PUR 4.341 4.341 4.341 4.341 4.341 4.341 4.341 4.341 Extension cable Extension cable

Outer jacket material PVC 4.322 4.322 4.322 4.322 4.322 PUR 4.342 4.341 4.342 4.342 4.342

page TPE

SIEMENS

Stber Selection table according to part numbers and sheath materials.


Outer jacket material PVC PUR page TPE

STBER

Gr.1-Motor-2,5mm Gr.1-Motor-4,0mm Gr.1,5-Motor-4,0mm Gr.1,5-Motor-6,0mm Gr.1,5-Motor-10,0mm Encoder ED/EK iSDS4000 Encoder ES iSDS4000 Encoder iMDS5000 Resolver iMDS5000 Resolver iSDS4000

4.307

Servo PVC

Chainflex-PVC-Servo cable
G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

B&R Basic cable


B&R
i8CMxxx.12-1 i8CMxxx.12-3 MAT9610001 MAT9610002 (4 G 1,5+2x(2x0,75)C)C (4 G 4,0+2x(2x1,5)C)C 14,5 18,5

B&R Basic cable


i8CMxxx.12-5 MAT9610003 (4 G 10,0+2x(2x1,5)C)C 24,0

Baumller 15 A-Basic cable*


324781 (5 m) 324782 (7 m) 324783 (10 m) 324784 (15 m) 324785 (20 m) 324786 (25 m) MAT9295001 MAT9295002 MAT9295003 MAT9295004 MAT9295005 MAT9295006 MAT9295007 MAT9295008 MAT9295009 MAT9295010 MAT9295011 MAT9295012 (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5

BAUMLLER

324787 (30 m) 324788 (35 m) 324789 (40 m) 324790 (50 m) 324791 (75 m) 324792 (100 m)

Baumller 15 A-Extension cable


MAT9297001 (4 G 1,5+2x(2x0,75)C)C 14,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.308 (for up to 10 cuts of the same type)

Servo PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Baumller 20 A-Basic cable*


414840 (5 m) 380967 (7 m) 413410 (10 m) 414841 (15 m) 414842 (20 m) 414843 (25 m) 414846 (30 m) 414848 (35 m) 414849 (40 m) 414850 (50 m) MAT9295020 MAT9295021 MAT9295022 MAT9295023 MAT9295024 MAT9295025 MAT9295026 MAT9295027 MAT9295028 MAT9295029 MAT9295030 MAT9295031 (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5

BAUMLLER

414851 (75 m) 414852 (100 m)

Baumller 20 A-Extension cable


MAT9297020 (4 G 2,5+2x(2x1,5)C)C 17,5

Baumller 21 A-Basic cable*


326577 (5 m) 326578 (7 m) 326579 (10 m) 326580 (15 m) 326581 (20m) 326582 (25 m) 326583 (30 m) 326584 (35 m) 326585 (40 m) 326586 (50 m) 326587 (70m) MAT9295040 MAT9295041 MAT9295042 MAT9295043 MAT9295044 MAT9295045 MAT9295046 MAT9295047 MAT9295048 MAT9295049 MAT9295050 (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5 17,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.309

Servo PVC

Chainflex-PVC-Servo cable
G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No. 326588 (100 m)

igus Part No. MAT9295051

Number of cores and conductor nominal cross section [mm ]


2

mm 17,5

(4 G 2,5+2x(2x1,5)C)C

Baumller 21 A-Extension cable


MAT9297040 (4 G 2,5+2x(2x1,5)C)C 17,5

Baumller 28 A-Basic cable*


326589 (5 m) 326591 (7 m) 326592 (10 m) 326593 (15 m) MAT9295060 MAT9295061 MAT9295062 MAT9295063 MAT9295064 MAT9295065 MAT9295066 MAT9295067 MAT9295068 (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5 18,5

BAUMLLER

326594 (20m) 326596 (25 m) 326597 (30 m) 326598 (35 m) 326599 (40 m)

Baumller 28 A-Extension cable


MAT9297060 (4 G 4+2x(2x1,5)C)C 18,5 128,79

Baumller 36 A-Basic cable*


326600 (5 m) 326601 (7 m) 326602 (10 m) 326603 (15 m) 326604 (20m) 326605 (25 m) 326606 (30 m) 326607 (35 m) MAT9295070 MAT9295071 MAT9295072 MAT9295073 MAT9295074 MAT9295075 MAT9295076 MAT9295077 (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C 20,5 20,5 20,5 20,5 20,5 20,5 20,5 20,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.310

(for up to 10 cuts of the same type)

Servo PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No. 326608 (40 m)

igus Part No. MAT9295078

Number of cores and conductor nominal cross section [mm ]


2

mm 20,5

(4 G 6+2x(2x1,5)C)C

Baumller 36 A-Extension cable


MAT9297070 (4 G 6+2x(2x1,5)C)C 20,5

BAUMLLER

Baumller 50 A-Basic cable*


326609 (5 m) 326610 (7 m) 326611 (10 m) 326612 (15 m) 326613 (20m) 326614 (25 m) 326615 (30 m) 326616 (35 m) 326617 (40 m) MAT9295080 MAT9295081 MAT9295082 MAT9295083 MAT9295084 MAT9295085 MAT9295086 MAT9295087 MAT9295088 (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C 24,0 24,0 24,0 24,0 24,0 24,0 24,0 24,0 24,0

Baumller 50 A-Extension cable


MAT9297080 (4 G 10+2x(2x1,5)C)C 24,0

Beckhoff Basic cable


BECKHOFF
ZK4000-2111-xxxx MAT9371005 (4 G 1,5+(2x1)C)C 12,5 8

Beckhoff Basic cable


ZK4000-2112-xxxx MAT9371006 (4 G 2,5+(2x1)C)C 13,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.311

Servo PVC

Chainflex-PVC-Servo cable
G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Beckhoff Basic cable


ZK4500-0023-xxxx MAT9371001 (4 G 1,5+2x(2x0,75)C)C 14,5

BECKHOFF

Beckhoff Basic cable


ZK4500-0024-xxxx MAT9371002 (4 G 2,5+2x(2x1,5)C)C 17,5

Beckhoff Extension cable


ZK4501-0023-xxxx MAT9371003 (4 G 1,5+2x(2x0,75)C)C 14,5

Beckhoff Extension cable


ZK4501-0024-xxxx MAT9371004 (4 G 2,5+2x(2x1,5)C)C 17,5

BERGER LAHR

Berger Lahr Basic cable


VW3M5101Rxxx VW3M5102Rxxx MAT94502001 MAT94502003 (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C 12,5 13,5

CONTROL TECHNIQUES

Control Techniques Basic cable


PB B G A A XXX PB B A A A XXX PB B B A A XXX PB B G F A XXX PB B A F A XXX PB B B F A XXX MAT9560040 MAT9560041 MAT9560042 MAT9560043 MAT9560044 MAT9560045 (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C 12,5 13,5 16,0 12,5 13,5 16,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.312

(for up to 10 cuts of the same type)

Servo PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Control Techniques Basic cable


PB B G A B XXX PB B A A B XXX PB B B A B XXX PB B C A B XXX MAT9560046 MAT9560047 MAT9560048 MAT9560049 MAT9560050 MAT9560051 MAT9560052 MAT9560053 MAT9560054 MAT9560055 MAT9560056 MAT9560057 MAT9560058 MAT9560059 MAT9560060 MAT9560061 MAT9560062 MAT9560063 MAT9560064 MAT9560065 MAT9560066 MAT9560067 MAT9560068 MAT9560069 (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C 12,5 13,5 16,0 17,5 20,5 23,0 12,5 13,5 16,0 17,5 20,5 23,0 12,5 13,5 16,0 17,5 20,5 23,0 12,5 13,5 16,0 17,5 20,5 23,0

CONTROL TECHNIQUES DANAHER MOTION

PB B D A B XXX PB B E A B XXX PB B G F B XXX PB A A F B XXX PB B A F B XXX PB B C F B XXX PB B D F B XXX PB B E F B XXX PB B G B B XXX PB B A B B XXX PB B B B B XXX PB B C B B XXX PB B D B B XXX PB B E B B XXX PB B G G B XXX PB B A G B XXX PB B B G B XXX PB B C G B XXX PB B D G B XXX PB B E G B XXX

Danaher Motion Basic cable


107491 (5 m) 107492 (10 m) 107493 (15 m) 107494 (20 m) MAT9340001 MAT9340005 MAT9340006 MAT9340007 (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C 12,5 12,5 12,5 12,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.313

Servo PVC

Chainflex-PVC-Servo cable
G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No. 107495 (25 m) 107479 (5 m) 107480 (10 m) 107481 (15 m) 107482 (20 m) 107483 (25 m) 102579 (5 m) 102580 (10 m) 102809 (15 m) 102810 (20 m) 102811 (25 m) 90088 (5 m) 90089 (10 m)

igus Part No. MAT9340008 MAT9340009 MAT9340010 MAT9340011 MAT9340012 MAT9340013 MAT9340014 MAT9340015 MAT9340016 MAT9340017 MAT9340018 MAT9340019 MAT9340020 MAT9340021 MAT9340022 MAT9340023 MAT9340024 MAT9340025 MAT9340026 MAT9340027 MAT9340028

Number of cores and conductor nominal cross section [mm ]


2

mm 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5

(4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C

DANAHER MOTION

90090 (15 m) 90091 (20 m) 90092 (25 m) 89957 (5 m) 89961 (10 m) 89963 (15 m) 89965 (20 m) 89967 (25 m)

Danaher Motion Basic cable


89968 (5 m) 89970 (10 m) 89971 (15 m) 89972 (20 m) 89969 (25 m) 200462 (5 m) 200463 (10 m) 200464 (15 m) 200465 (20 m) 200466 (25 m) 200474 (5 m) MAT9340029 MAT9340030 MAT9340031 MAT9340032 MAT9340033 MAT9340034 MAT9340035 MAT9340036 MAT9340037 MAT9340038 MAT9340039 (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C 13,5 13,5 13,5 13,5 13,5 12,5 12,5 12,5 12,5 12,5 13,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.314

(for up to 10 cuts of the same type)

Servo PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No.

igus Part No. MAT9340040 MAT9340041 MAT9340042 MAT9340043 MAT9340044 MAT9340045 MAT9340046 MAT9340047 MAT9340048

Number of cores and conductor nominal cross section [mm ]


2

mm 13,5 13,5 13,5 13,5 15,5 15,5 15,5 15,5 15,5

DANAHER MOTION

200475 (10 m) 200476 (15 m) 200477 (20 m) 200478 (25 m) 200623 (5 m) 200624 (10 m) 200625 (15 m) 200626 (20 m) 200627 (25 m)

(4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 4,0+(2x1)C)C

ELAU Basic cable


E-MO-067 E-MO-092 MAT9470001 MAT9470004 (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C 14,5 14,5

ELAU Basic cable


ELAU
E-MO-111 SH-Motor 1,5 MAT9470002 (4 G 1,5+2x(2x0,75)C)C 14,5

ELAU Basic cable


E-MO-087 MAT9470003 (4 G 2,5+2x(2x1,5)C)C 17,0

ELAU Basic cable


E-MO-113 SH-Motor 2.5 MAT9470005 (4 G 2,5+2x(2x1,5)C)C 17,0

LENZE

Lenze Basic cable*


EWLMxxxGMS-015C EWLMxxxGMS-025 MAT9130001 MAT9130002 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C 12,5 13,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.315

Servo PVC

Chainflex-PVC-Servo cable
G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No. EYP0010AxxxxM01A00 EYP0011AxxxxM01A00 EYP0012AxxxxM01A00 EYP0012AxxxxM02A00 EYP0013AxxxxM02A00 EYP0014AxxxxM03A00 EYP0015AxxxxM03A00 EYP0016AxxxxM03A00 EYP0012xxxxA00P02 EYP0013xxxxA00P02 EYP0014xxxxA00P03 EYP0015xxxxA00P03

igus Part No. MAT9130050 MAT9130051 MAT9130052 MAT9130053 MAT9130054 MAT9130055 MAT9130056 MAT9130057 MAT9130058 MAT9130059 MAT9130060 MAT9130061 MAT9130062 MAT9130063 MAT9130064 MAT9130065

Number of cores and conductor nominal cross section [mm ]


2

mm 12,5 12,5 13,5 13,5 15,5 18,0 22,0 24,5 13,5 15,5 22,0 22,0 24,5 12,5 12,5 13,5

(4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C

LENZE

EYP0016xxxxA00P03 EYP0010xxxxA00P01 EYP0011xxxxA00P01 EYP0012xxxxA00P01

Lenze Linking cable


EWLMxxxZM-015C EWLMxxxZM-025 EYP0012VxxxxM02P02 EYP0013VxxxxM02P02 EYP0014VxxxxM03P03 EYP0015VxxxxM03P03 EYP0016VxxxxM03P03 EYP0010VxxxxM01P01 EYP0011VxxxxM01P01 EYP0012VxxxxM01P01 MAT9130006 MAT9130007 MAT9130066 MAT9130067 MAT9130068 MAT9130069 MAT9130070 MAT9130071 MAT9130072 MAT9130073 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C 12,5 13,5 13,5 15,5 18,0 22,0 24,5 12,5 12,5 13,5

NUM

NUM Basic cable


AGOFRU018Mxxx AGOFRU019Mxxx MAT9280001 MAT9280002 (4 G 1,5+(2x1)C)C (4 G 4,0+(2x1,5)C)C 12,5 16,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.316

(for up to 10 cuts of the same type)

Servo PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

NUM Basic cable*


AGOFRU020Mxxx MAT9280003 (4 G 10,0+(2x1,5)C)C 22,5

NUM

NUM Extension cable


AGOFRU018Mxxx AGOFRU019Mxxx MAT9280011 MAT9280012 (4 G 1,5+(2x1)C)C (4 G 4,0+(2x1,5)C)C 12,5 16,0

NUM Extension cable


AGOFRU020Mxxx MAT9280013 (4 G 10,0+(2x1,5)C)C 22,5

Rexroth Basic cable


IKG0001 IKG0006 IKG0011 IKG0021 MAT9190022 MAT9190067 MAT9190023 MAT9190024 MAT9190017 MAT9190077 MAT9190018 MAT9190030 MAT9190025 MAT9190019 MAT9190063 MAT9190014 MAT9190064 MAT9190001 MAT9190002 MAT9190003 (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C (4G0,75+(2x0,5)C)C (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C 13,5 13,5 13,5 16,0 16,0 16,0 18,0 19,5 19,5 23,5 30,0 11,0 14,5 14,5 14,5 14,5

REXROTH

IKG0041 IKG0042 IKG0061 IKG0081 IKG0101 IKG0121 IKG0161 IKG0331 IKG4008 IKG4009 IKG4017 IKG4018

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.317

Servo PVC

Chainflex-PVC-Servo cable
G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No. IKG4020 IKG4055 IKG4060 IKG4067 IKG4070 IKG4072 IKG4087 IKG4090 IKG4100 IKG4103 IKG4107 IKG4118 IKG4119 IKG4147 IKG4150 IKG4155 IKG4164 IKG4167 IKG4172 IKG4173 IKG4186 IKG4200 IKG4204

igus Part No. MAT9190004 MAT9190005 MAT9190006 MAT9190007 MAT9190008 MAT9190068 MAT9190009 MAT9190010 MAT9190020 MAT9190076 MAT9190011 MAT9190070 MAT9190027 MAT9190038 MAT9190012 MAT9190028 MAT9190035 MAT9190013 MAT9190069 MAT9190072 MAT9190021 MAT9190032 MAT9190052

Number of cores and conductor nominal cross section [mm ]


2

mm 14,5 14,5 14,5 16,5 16,5 16,5 18,5 18,5 13,5 20,5 20,5 20,5 13,5 20,5 20,5 19,5 23,5 24,0 26,0 30,0 26,0 26,0 30,0

(4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G1,0+2x(2x0,75)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G1,0+2x(2x0,75)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C

REXROTH

Rexroth Connecting cable with adapter plugs


IKG0023 IKG0089 IKG0168 IKG0332 IKG4006 IKG4016 IKG4061 IKG4074 IKG4081 MAT9191013 MAT9191005 MAT9191006 MAT9190015 MAT9191001 MAT9191002 MAT9191004 MAT9191014 MAT9191016 (4G1,5+2x(2x0,75)C)C (4G6,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C (4G0,75+(2x0,5)C)C (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C 14,5 19,5 30,0 11,0 14,5 14,5 16,5 16,5 20,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.318

(for up to 10 cuts of the same type)

Servo PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No. IKG4141 IKG4161

igus Part No. MAT9191003 MAT9191036

Number of cores and conductor nominal cross section [mm ]


2

mm 19,5 23,5

(4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C

Rexroth Basic cable


RKL4300 RKL4301 RKL4302 RKL4303 RKL4306 RKL4307 RKL4308 RKL4309 RKL4310 RKL4313 RKL4314 RKL4315 RKL4317 RKL4318 RKL4320 RKL4321 RKL4322 RKL4323 RKL4324 RKL4325 RKL4326 RKL4327 RKL4328 RKL4329 RKL4330 RKL4331 MAT9190071 MAT9190037 MAT9190026 MAT9190029 MAT9190040 MAT9190041 MAT9190033 MAT9190042 MAT9190043 MAT9190062 MAT9190060 MAT9190059 MAT9190061 MAT9190047 MAT9190039 MAT9190075 MAT9190078 MAT9190073 MAT9190079 MAT9190049 MAT9190045 MAT9190050 MAT9190057 MAT9190051 MAT9190080 MAT9190081 (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C 14,5 14,5 13,5 13,5 14,5 14,5 16,0 16,0 16,0 18,0 18,8 18,0 19,5 19,5 14,5 16,0 18,0 19,5 23,5 14,5 16,0 18,0 19,5 23,5 26,0 30,0

REXROTH

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.319

Servo PVC

Chainflex-PVC-Servo cable
G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

REXROTH

Rexroth Connecting cable with adapter plugs


RKL4304 RKL4305 RKL4311 RKL4312 RKL4316 RKL4319 RKL4336 RKL4338 RKL4340 MAT9191007 MAT9191008 MAT9191009 MAT9191010 MAT9191011 MAT9191012 MAT9191018 MAT9191017 MAT9191015 (4G1,5+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C 14,5 13,5 14,5 16,0 18,0 19,5 16,0 19,5 26,0

SEW Connection cable (Amphenol)


199 190 6 199 192 2 199 194 9 199 196 5 199 198 1 MAT9410001 MAT9410002 MAT9410003 MAT9410004 MAT9410005 (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C 14,5 16,5 18,0 19,5 23,5

SEW Extension cable (Amphenol)


199 200 7 199 202 3 199 204 X 199 206 6 199 208 2 MAT9411001 MAT9411002 MAT9411003 MAT9411004 MAT9411005 (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C 14,5 17,0 18,5 20,5 24,0

SEW

SEW Connection cable (Amphenol)


1332 486 1 MAT9410011 (4 G 1,5+1x(2x1,0)C)C 12,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.320

(for up to 10 cuts of the same type)

Servo PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

SEW

SEW Extension cable (Amphenol)


0593 650 0 MAT9411011 (4 G 1,5+1x(2x1,0)C)C 12,5

Siemens Basic cable


6FX8002-5DA01 6FX8002-5DA11 MAT9160001 MAT9160002 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C 12,5 13,5

Siemens Basic cable


6FX8002-5DA21 6FX8002-5DA31 6FX8002-5DA41 6FX8002-5DA51 6FX8002-5DA61 MAT9160003 MAT9160004 MAT9160005 MAT9160006 MAT9160007 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 4,0+(2x1,0)C)C (4 G 6,0+(2x1,0)C)C (4 G 10,0+(2x1,5)C)C 12,5 13,5 15,5 18,0 22,0

SIEMENS

Siemens Basic cable


6FX8002-5DA23 6FX8002-5DA33 6FX8002-5DA43 MAT9160008 MAT9160009 MAT9160010 (4 G 16,0+(2x1,0)C)C (4 G 25,0+(2x1,5)C)C (4 G 35,0+(2x1,5)C)C 24,5 29,5 33,0

Siemens Basic cable


6FX8002-5DS01 6FX8002-5DS21 6FX8002-5DS61 MAT9160020 MAT9160021 MAT9160022 (4G1,5+(2x1,0)C)C (4G1,5+(2x1,0)C)C (4G10,0+(2x1,5)C)C 12,5 12,5 22,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.321

Servo PVC

Chainflex-PVC-Servo cable
G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Siemens Extension cable


6FX8002-5DA05 6FX8002-5DA15 MAT9161001 MAT9161002 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C 12,5 13,5

SIEMENS

Siemens Extension cable


6FX8002-5DA28 6FX8002-5DA38 6FX8002-5DA48 6FX8002-5DA58 6FX8002-5DA68 MAT9161003 MAT9161004 MAT9161005 MAT9161006 MAT9161007 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 4,0+(2x1,0)C)C (4 G 6,0+(2x1,0)C)C (4 G 10,0+(2x1,5)C)C 12,5 13,5 15,5 18,0 22,0

Siemens Extension cable


6FX8002-5DX28 6FX8002-5DX38 6FX8002-5DX48 MAT9161008 MAT9161009 MAT9161010 (4 G 16,0+(2x1,0)C)C (4 G 25,0+(2x1,5)C)C (4 G 35,0+(2x1,5)C)C 24,5 29,5 33,0

Stber iMDS5000 & iSDS4000 Basic cable


Gr.1-Motor-1,0mm2 MAT9430001 MAT9430002 MAT9430003 MAT9430004 (4G1,0+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C 13,5 14,5 16,5 17,5

STBER

Gr.1-Motor-1,5mm2 Gr.1-Motor-2,5mm
2

Gr.1-Motor-4,0mm2

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.322

(for up to 10 cuts of the same type)

Servo PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

STBER

Stber iMDS5000 & iSDS4000 Basic cable


Gr.1,5-Motor-4,0mm2 Gr.1,5-Motor-6,0mm2 Gr.1,5-Motor-10,0mm
2

MAT9430005 MAT9430006 MAT9430007

(4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C

18,5 20,5 24,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.323

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 4.1.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: bending-resistant, tinned braided copper shield. Coverage approx. 55 % linear, approx. 80 % optical.

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Fanuc Basic cable


LX660-8077-T261 MAT9200061 (4 G 1,5)C 8,5

Fanuc Basic cable


LX660-8077-T264 LX660-8077-T266 MAT9200064 MAT9200066 (4 G 2,5)C (4 G 2,5)C 10,5 10,5

Fanuc Basic cable


FANUC
LX660-8077-T265 LX660-8077-T267 MAT9200065 MAT9200067 (4 G 2,5)C (4 G 2,5)C 10,5 10,5

Fanuc Basic cable


LX660-8077-T270(1) LX660-8077-T272 MAT9200070 MAT9200072 (4 G 4,0)C (4 G 10,0)C 12,0 17,5

Fanuc Basic cable


LX660-8077-T271(1) LX660-8077-T273 MAT9200071 MAT9200073 (4 G 4,0)C (4 G 10,0)C 12,0 17,5

Fanuc Basic cable


LX660-8077-T291 LX660-8077-T293
(1)

MAT9200091 MAT9200093

(4 G 2,5)C (4 G 4,0)C

10,5 12,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. Image exemplary. (1) Lieferzeit auf Anfrage. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.324

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Fanuc Basic cable


LX660-8077-T292(1) MAT9200092 (4 G 4,0)C 12,0

FANUC

Fanuc Basic cable


LX660-8077-T296 MAT9200096 (4 G 2,5)C 10,5

Fanuc Basic cable


LX660-8077-T298(1) MAT9200098 (4 G 4,0)C 15,5

Fanuc Basic cable


LX660-8077-T300 MAT9200300 (4 G 2,5)C 12,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. (1) Lieferzeit auf Anfrage. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.325

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

B&R Basic cable


B&R
i8CMxxx.12-1 i8CMxxx.12-3 MAT9600001 MAT9600002 (4 G 1,5+2x(2x0,75)C)C (4 G 4,0+2x(2x1,5)C)C 14,5 18,0

B&R Basic cable


i8CMxxx.12-5 MAT9600003 (4 G 10,0+2x(2x1,5)C)C 23,5

Baumller 15 A-Basic cable*


324781 (5 m) 324782 (7 m) 324783 (10 m) 324784 (15 m) 324785 (20 m) 324786 (25 m) MAT9296001 MAT9296002 MAT9296003 MAT9296004 MAT9296005 MAT9296006 MAT9296007 MAT9296008 MAT9296009 MAT9296010 MAT9296011 MAT9296012 (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5 14,5

BAUMLLER

324787 (30 m) 324788 (35 m) 324789 (40 m) 324790 (50 m) 324791 (75 m) 324792 (100 m)

Baumller 15 A-Extension cable


MAT9298001 (4 G 1,5+2x(2x0,75)C)C 14,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.326

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Baumller 20 A-Basic cable*


414840 (5 m) 380967 (7 m) 413410 (10 m) 414841 (15 m) 414842 (20 m) 414843 (25 m) 414846 (30 m) 414848 (35 m) 414849 (40 m) 414850 (50 m) MAT9296020 MAT9296021 MAT9296022 MAT9296023 MAT9296024 MAT9296025 MAT9296026 MAT9296027 MAT9296028 MAT9296029 MAT9296030 MAT9296031 (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5

BAUMLLER

414851 (75 m) 414852 (100 m)

Baumller 20 A-Extension cable


MAT9298020 (4 G 2,5+2x(2x1,5)C)C 16,5

Baumller 21 A-Basic cable*


326577 (5 m) 326578 (7 m) 326579 (10 m) 326580 (15 m) 326581 (20m) 326582 (25 m) 326583 (30 m) 326584 (35 m) 326585 (40 m) 326586 (50 m) 326587 (70m) MAT9296040 MAT9296041 MAT9296042 MAT9296043 MAT9296044 MAT9296045 MAT9296046 MAT9296047 MAT9296048 MAT9296049 MAT9296050 (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 2,5+2x(2x1,5)C)C 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5 16,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.327

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No. 326588 (100 m)

igus Part No. MAT9296051

Number of cores and conductor nominal cross section [mm ]


2

mm 16,5

(4 G 2,5+2x(2x1,5)C)C

Baumller 21 A-Extension cable


MAT9298040 (4 G 2,5+2x(2x1,5)C)C 16,5

Baumller 28 A-Basic cable*


326589 (5 m) 326591 (7 m) 326592 (10 m) 326593 (15 m) MAT9296060 MAT9296061 MAT9296062 MAT9296063 MAT9296064 MAT9296065 MAT9296066 MAT9296067 MAT9296068 (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C 18,0 18,0 18,0 18,0 18,0 18,0 18,0 18,0 18,0

BAUMLLER

326594 (20m) 326596 (25 m) 326597 (30 m) 326598 (35 m) 326599 (40 m)

Baumller 28 A-Extension cable


MAT9298060 (4 G 4+2x(2x1,5)C)C 18,0

Baumller 36 A-Basic cable*


326600 (5 m) 326601 (7 m) 326602 (10 m) 326603 (15 m) 326604 (20m) 326605 (25 m) 326606 (30 m) 326607 (35 m) MAT9296070 MAT9296071 MAT9296072 MAT9296073 MAT9296074 MAT9296075 MAT9296076 MAT9296077 (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C 19,5 19,5 19,5 19,5 19,5 19,5 19,5 19,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.328

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No. 326608 (40 m)

igus Part No. MAT9296078

Number of cores and conductor nominal cross section [mm ]


2

mm 19,5

(4 G 6+2x(2x1,5)C)C

Baumller 36 A-Extension cable


MAT9298070 (4 G 6+2x(2x1,5)C)C 19,5

BAUMLLER

Baumller 50 A-Basic cable*


326609 (5 m) 326610 (7 m) 326611 (10 m) 326612 (15 m) 326613 (20m) 326614 (25 m) 326615 (30 m) 326616 (35 m) 326617 (40 m) MAT9296080 MAT9296081 MAT9296082 MAT9296083 MAT9296084 MAT9296085 MAT9296086 MAT9296087 MAT9296088 (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C 23,5 23,5 23,5 23,5 23,5 23,5 23,5 23,5 23,5

Baumller 50 A-Extension cable


MAT9298080 (4 G 10+2x(2x1,5)C)C 23,5

Beckhoff Basic cable


BECKHOFF
ZK4000-2111-xxxx MAT9372005 (4 G 1,5+(2x1)C)C 12,5

Beckhoff Basic cable


ZK4000-2112-xxxx MAT9372006 (4 G 2,5+(2x1)C)C 13,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.329

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Beckhoff Basic cable


ZK4500-0023-xxxx MAT9372001 (4 G 1,5+2x(2x0,75)C)C 14,5

BECKHOFF

Beckhoff Basic cable


ZK4500-0024-xxxx MAT9372002 (4 G 2,5+2x(2x1,5)C)C 17,5

Beckhoff Extension cable


ZK4501-0023-xxxx MAT9372003 (4 G 1,5+2x(2x0,75)C)C 14,5

Beckhoff Extension cable


ZK4501-0024-xxxx MAT9372004 (4 G 2,5+2x(2x1,5)C)C 17,5

BERGER LAHR

Berger Lahr Basic cable


VW3M5101Rxxx VW3M5102Rxxx MAT94500001 MAT94500003 (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C 12,5 13,5

CONTROL TECHNIQUES

Control Techniques Basic cable


PB B G A A XXX PB B A A A XXX PB B B A A XXX PB B G F A XXX PB B A F A XXX PB B B F A XXX MAT9540040 MAT9540041 MAT9540042 MAT9540043 MAT9540044 MAT9540045 (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C 12,5 13,5 16,0 12,5 13,5 16,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.330

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Control Techniques Basic cable


PB B G A B XXX PB B A A B XXX PB B B A B XXX PB B C A B XXX MAT9540046 MAT9540047 MAT9540048 MAT9540049 MAT9540050 MAT9540051 MAT9540052 MAT9540053 MAT9540054 MAT9540055 MAT9540056 MAT9540057 MAT9540058 MAT9540059 MAT9540060 MAT9540061 MAT9540062 MAT9540063 MAT9540064 MAT9540065 MAT9540066 MAT9540067 MAT9540068 MAT9540069 (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C 12,5 13,5 16,0 17,5 20,5 23,0 12,5 13,5 16,0 17,5 20,5 23,0 12,5 13,5 16,0 17,5 20,5 23,0 12,5 13,5 16,0 17,5 20,5 23,0

CONTROL TECHNIQUES DANAHER MOTION

PB B D A B XXX PB B E A B XXX PB B G F B XXX PB B A F B XXX PB B B F B XXX PB B C F B XXX PB B D F B XXX PB B E F B XXX PB B G B B XXX PB B A B B XXX PB B B B B XXX PB B C B B XXX PB B D B B XXX PB B E B B XXX PB B G G B XXX PB B A G B XXX PB B B G B XXX PB B C G B XXX PB B D G B XXX PB B E G B XXX

Danaher Motion Basic cable


107491 (5 m) 107492 (10 m) 107493 (15 m) 107494 (20 m) MAT9440001 MAT9440005 MAT9440006 MAT9440007 (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C 12,5 12,5 12,5 12,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.331

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No. 107495 (25 m) 107479 (5 m) 107480 (10 m) 107481 (15 m) 107482 (20 m) 107483 (25 m) 102579 (5 m) 102580 (10 m) 102809 (15 m) 102810 (20 m) 102811 (25 m) 90088 (5 m) 90089 (10 m)

igus Part No. MAT9440008 MAT9440009 MAT9440010 MAT9440011 MAT9440012 MAT9440013 MAT9440014 MAT9440015 MAT9440016 MAT9440017 MAT9440018 MAT9440019 MAT9440020 MAT9440021 MAT9440022 MAT9440023 MAT9440024 MAT9440025 MAT9440026 MAT9440027 MAT9440028

Number of cores and conductor nominal cross section [mm ]


2

mm 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5 12,5

(4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C

DANAHER MOTION

90090 (15 m) 90091 (20 m) 90092 (25 m) 89957 (5 m) 89961 (10 m) 89963 (15 m) 89965 (20 m) 89967 (25 m)

Danaher Motion Basic cable


89968 (5 m) 89970 (10 m) 89971 (15 m) 89972 (20 m) 89969 (25 m) 200462 (5 m) 200463 (10 m) 200464 (15 m) 200465 (20 m) 200466 (25 m) 200474 (5 m) MAT9440029 MAT9440030 MAT9440031 MAT9440032 MAT9440033 MAT9440034 MAT9440035 MAT9440036 MAT9440037 MAT9440038 MAT9440039 (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C 13,5 13,5 13,5 13,5 13,5 12,5 12,5 12,5 12,5 12,5 13,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.332

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No.

igus Part No. MAT9440040 MAT9440041 MAT9440042 MAT9440043 MAT9440044 MAT9440045 MAT9440046 MAT9440047 MAT9440048

Number of cores and conductor nominal cross section [mm ]


2

mm 13,5 13,5 13,5 13,5 16,0 16,0 16,0 16,0 16,0

DANAHER MOTION

200475 (10 m) 200476 (15 m) 200477 (20 m) 200478 (25 m) 200623 (5 m) 200624 (10 m) 200625 (15 m) 200626 (20 m) 200627 (25 m)

(4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 4,0+(2x1)C)C

ELAU Basic cable


E-MO-067 E-MO-092 MAT9470101 MAT9470104 (4 G 1,5+2x(2x0,75)C)C (4 G 1,5+2x(2x0,75)C)C 14,5 14,5

ELAU Basic cable


ELAU
E-MO-111 SH-Motor 1,5 MAT9470102 (4 G 1,5+2x(2x0,75)C)C 14,5

ELAU Basic cable


E-MO-087 MAT9470103 (4 G 2,5+2x(2x1,5)C)C 16,5

ELAU Basic cable


E-MO-113 SH-Motor 2.5 MAT9470105 (4 G 2,5+2x(2x1,5)C)C 16,5

FANUC

Fanuc Basic cable


LX660-8077-T261 MAT9210061 (4 G 1,5)C 10,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.333

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Fanuc Basic cable


LX660-8077-T264 LX660-8077-T266 MAT9210064 MAT9210066 (4 G 2,5)C (4 G 2,5)C 12,0 12,0

Fanuc Basic cable


LX660-8077-T265 LX660-8077-T267 MAT9210065 MAT9210067 (4 G 2,5)C (4 G 2,5)C 12,0 12,0

Fanuc Basic cable


FANUC
LX660-8077-T270* LX660-8077-T272 MAT9210070 MAT9210072 (4 G 4,0)C (4 G 10,0)C 15,5 20,5

Fanuc Basic cable


LX660-8077-T271* LX660-8077-T273 MAT9210071 MAT9210073 (4 G 4,0)C (4 G 10,0)C 15,5 20,5

Fanuc Basic cable


LX660-8077-T291 LX660-8077-T293* MAT9210091 MAT9210093 (4 G 2,5)C (4 G 4,0)C 12,0 15,5

Fanuc Basic cable


LX660-8077-T292* MAT9210092 (4 G 4,0)C 15,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.334

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Fanuc Basic cable


FANUC
LX660-8077-T296 MAT9210096 (4 G 2,5)C 12,0

Fanuc Basic cable


LX660-8077-T298* MAT9210098 (4 G 4,0)C 15,5

Fanuc Basic cable


LX660-8077-T300 MAT9210300 (4 G 2,5)C 12,0

Lenze Basic cable*


EWLMxxxGMS-015C EWLMxxxGMS-025 EYP0010AxxxxM01A00 EYP0011AxxxxM01A00 EYP0012AxxxxM01A00 MAT9120001 MAT9120002 MAT9120050 MAT9120051 MAT9120052 MAT9120053 MAT9120054 MAT9120055 MAT9120056 MAT9120057 MAT9120058 MAT9120059 MAT9120060 MAT9120061 MAT9120062 MAT9120063 MAT9120064 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 1,5+(2x1,0)C)C (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 4,0+(2x1,0)C)C (4 G 6,0+(2x1,0)C)C (4 G 10,0+(2x1,0)C)C (4 G 16,0+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 4,0+(2x1,0)C)C (4 G 6,0+(2x1,0)C)C (4 G 10,0+(2x1,0)C)C (4 G 16,0+(2x1,0)C)C (4 G 1,5+(2x1,0)C)C (4 G 1,5+(2x1,0)C)C 12,5 13,5 12,5 12,5 13,5 13,5 15,5 17,5 20,5 23,0 13,5 15,5 20,5 20,5 23,0 12,5 12,5

LENZE

EYP0012AxxxxM02A00 EYP0013AxxxxM02A00 EYP0014AxxxxM03A00 EYP0015AxxxxM03A00 EYP0016AxxxxM03A00 EYP0012xxxxA00P02 EYP0013xxxxA00P02 EYP0014xxxxA00P03 EYP0015xxxxA00P03 EYP0016xxxxA00P03 EYP0010xxxxA00P01 EYP0011xxxxA00P01

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.335

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No. EYP0012xxxxA00P01

igus Part No. MAT9120065

Number of cores and conductor nominal cross section [mm ]


2

mm 13,5

(4 G 2,5+(2x1,0)C)C

Lenze Linking cable


LENZE
EWLMxxxZM-015C EWLMxxxZM-025 EYP0012VxxxxM02P02 EYP0013VxxxxM02P02 EYP0014VxxxxM03P03 EYP0015VxxxxM03P03 EYP0016VxxxxM03P03 EYP0010VxxxxM01P01 EYP0011VxxxxM01P01 EYP0012VxxxxM01P01 MAT9120006 MAT9120007 MAT9120066 MAT9120067 MAT9120068 MAT9120069 MAT9120070 MAT9120071 MAT9120072 MAT9120073 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 2,5+(2x1)C)C (4 G 4,0+(2x1)C)C (4 G 6,0+(2x1)C)C (4 G 10,0+(2x1)C)C (4 G 16,0+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 1,5+(2x1)C)C (4 G 2,5+(2x1)C)C 12,5 13,5 13,5 15,5 17,5 20,5 23,0 12,5 12,5 13,5

NUM Basic cable


AGOFRU018Mxxx AGOFRU019Mxxx MAT9282001 MAT9282002 (4 G 1,5+(2x1)C)C (4 G 4,0+(2x1)C)C 12,5 16,0

NUM Basic cable*


NUM
AGOFRU020Mxxx MAT9282003 (4 G 10,0+(2x1)C)C 20,5

NUM Extension cable


AGOFRU018Mxxx AGOFRU019Mxxx MAT9282011 MAT9282012 (4 G 1,5+(2x1)C)C (4 G 4,0+(2x1)C)C 12,5 16,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.336

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

NUM

NUM Extension cable


AGOFRU020Mxxx MAT9282013 (4 G 10,0+(2x1)C)C 20,5

Rexroth Basic cable


IKG0001 IKG0006 IKG0011 IKG0021 IKG0041 IKG0042 IKG0061 IKG0081 IKG0101 IKG0121 IKG0161 IKG0331 IKG4008 IKG4009 IKG4017 IKG4018 IKG4020 IKG4055 IKG4060 IKG4067 IKG4070 IKG4072 IKG4087 IKG4090 IKG4100 IKG4103 IKG4107 MAT9090022 MAT9090067 MAT9090023 MAT9090024 MAT9090017 MAT9090077 MAT9090018 MAT9090030 MAT9090025 MAT9090019 MAT9090063 MAT9090014 MAT9090064 MAT9090001 MAT9090002 MAT9090003 MAT9090004 MAT9090005 MAT9090006 MAT9090007 MAT9090008 MAT9090068 MAT9090009 MAT9090010 MAT9090020 MAT9090076 MAT9090011 (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C (4G0,75+(2x0,5)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G1,0+2x(2x0,75)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C 13,5 13,5 13,5 16,0 16,0 16,0 18,0 19,5 19,5 23,5 30,0 11,5 13,5 13,5 13,5 13,5 13,5 14,5 14,5 16,0 16,0 16,0 18,0 18,0 13,5 19,5 19,5

REXROTH

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.337

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No. IKG4118 IKG4119 IKG4147 IKG4150 IKG4155 IKG4164 IKG4167 IKG4172 IKG4173 IKG4186 IKG4200 IKG4204

igus Part No. MAT9090070 MAT9090027 MAT9090038 MAT9090012 MAT9090028 MAT9090035 MAT9090013 MAT9090069 MAT9090072 MAT9090021 MAT9090032 MAT9090052

Number of cores and conductor nominal cross section [mm ]


2

mm 19,5 13,5 19,5 19,5 19,5 23,5 23,5 26,0 30,0 26,0 26,0 30,0

(4G6,0+2x(2x1,5)C)C (4G1,0+2x(2x0,75)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C

REXROTH

Rexroth Connecting cable with adapter plugs


IKG0023 IKG0089 IKG0168 IKG0332 IKG4006 IKG4016 IKG4061 IKG4074 IKG4081 IKG4141 IKG4161 MAT9091013 MAT9091005 MAT9091006 MAT9090015 MAT9091001 MAT9091002 MAT9091004 MAT9091014 MAT9091016 MAT9091003 MAT9090036 (4G1,5+2x(2x0,75)C)C (4G6,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C (4G0,75+(2x0,5)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C 14,5 19,5 30,0 11,5 13,5 13,5 16,0 16,0 18,0 19,5 23,5

Rexroth Basic cable


RKL4300 RKL4301 RKL4302 RKL4303 RKL4306 MAT9090071 MAT9090037 MAT9090026 MAT9090029 MAT9090040 (4G1,5+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C 14,5 14,5 13,5 13,5 14,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.338

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No. RKL4307 RKL4308 RKL4309 RKL4310 RKL4313 RKL4314 RKL4315 RKL4317 RKL4318 RKL4320 RKL4321 RKL4322 RKL4323 RKL4324 RKL4325 RKL4326 RKL4327 RKL4328 RKL4329 RKL4330 RKL4331

igus Part No. MAT9090041 MAT9090033 MAT9090042 MAT9090043 MAT9090062 MAT9090060 MAT9090059 MAT9090061 MAT9090047 MAT9090039 MAT9090075 MAT9090078 MAT9090073 MAT9090079 MAT9090049 MAT9090045 MAT9090050 MAT9090057 MAT9090051 MAT9090080 MAT9090081

Number of cores and conductor nominal cross section [mm ]


2

mm 14,5 16,0 16,0 16,0 18,0 18,0 18,0 19,5 19,5 14,5 16,0 18,0 19,5 23,5 14,5 16,0 18,0 19,5 23,5 26,0 30,0

(4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C (4G25,0+2x(2x1,5)C)C

REXROTH

Rexroth Connecting cable with adapter plugs


RKL4304 RKL4305 RKL4311 RKL4312 RKL4316 RKL4319 RKL4336 RKL4338 RKL4340 MAT9091007 MAT9091008 MAT9091009 MAT9091010 MAT9091011 MAT9091012 MAT9091018 MAT9091017 MAT9091015 (4G1,5+2x(2x0,75)C)C (4G1,0+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G2,5+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G16,0+2x(2x1,5)C)C 14,5 13,5 14,5 16,0 18,0 19,5 16,0 19,5 26,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.339

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

SEW Connection cable


199 190 6 199 192 2 199 194 9 199 196 5 199 198 1 MAT9400001 MAT9400002 MAT9400003 MAT9400004 MAT9400005 (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C 14,5 16,5 18,0 19,5 23,5

SEW

SEW Extension cable


199 200 7 199 202 3 199 204 X 199 206 6 199 208 2 MAT9401001 MAT9401002 MAT9401003 MAT9401004 MAT9401005 (4 G 1,5+2x(2x0,75)C)C (4 G 2,5+2x(2x1,5)C)C (4 G 4+2x(2x1,5)C)C (4 G 6+2x(2x1,5)C)C (4 G 10+2x(2x1,5)C)C 14,5 16,5 18,0 19,5 23,5

SEW Connection cable


1332 486 1 MAT9400011 (4 G 1,5+1x(2x1,0)C)C 12,5

SEW Extension cable


0593 650 0 MAT9401011 (4 G 1,5+1x(2x1,0)C)C 12,5

SIEMENS

Siemens Basic cable


6FX8002-5DA01 6FX8002-5DA11 MAT9060001 MAT9060002 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C 12,5 13,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.340

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Siemens Basic cable


6FX8002-5DA21 6FX8002-5DA31 6FX8002-5DA41 6FX8002-5DA51 6FX8002-5DA61 MAT9060003 MAT9060004 MAT9060005 MAT9060006 MAT9060007 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 4,0+(2x1,0)C)C (4 G 6,0+(2x1,0)C)C (4 G 10,0+(2x1,0)C)C 12,5 13,5 15,5 17,5 20,5

Siemens Basic cable


6FX8002-5DA23 MAT9060008 MAT9060009 MAT9060010 (4 G 16,0+(2x1,0)C)C (4 G 25,0+(2x1,5)C)C (4 G 35,0+(2x1,5)C)C 24,0 28,5 32,5

SIEMENS

6FX8002-5DA33 6FX8002-5DA43

Siemens Basic cable


6FX8002-5DS01 6FX8002-5DS21 6FX8002-5DS61 MAT9060020 MAT9060021 MAT9060022 (4G1,5+(2x1,0)C)C (4G1,5+(2x1,0)C)C (4G10,0+(2x1,0)C)C 12,5 12,5 20,5

Siemens Extension cable


6FX8002-5DA05 6FX8002-5DA15 MAT9061001 MAT9061002 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C 12,5 13,5

Siemens Extension cable


6FX8002-5DA28 6FX8002-5DA38 6FX8002-5DA48 MAT9061003 MAT9061004 MAT9061005 (4 G 1,5+(2x1,0)C)C (4 G 2,5+(2x1,0)C)C (4 G 4,0+(2x1,0)C)C 12,5 13,5 15,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.341

Servo PUR

Chainflex-PUR-Servo cable
G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No. 6FX8002-5DA58

igus Part No. MAT9061006 MAT9061007

Number of cores and conductor nominal cross section [mm ]


2

mm 17,5 20,5

(4 G 6,0+(2x1,0)C)C (4 G 10,0+(2x1,0)C)C

SIEMENS

6FX8002-5DA68

Siemens Extension cable


6FX8002-5DX28 6FX8002-5DX38 6FX8002-5DX48 MAT9061008 MAT9061009 MAT9061010 (4 G 16,0+(2x1,0)C)C (4 G 25,0+(2x1,5)C)C (4 G 35,0+(2x1,5)C)C 24,0 28,5 32,5

Stber iMDS5000 & iSDS4000 Basic cable


Gr.1-Motor-1,0mm2 Gr.1-Motor-1,5mm
2

MAT9420001 MAT9420002 MAT9420003 MAT9420004

(4G1,0+2x(2x0,75)C)C (4G1,5+2x(2x0,75)C)C (4G2,5+2x(2x1,5)C)C (4G4,0+2x(2x1,5)C)C

13,5 14,5 16,5 18,0

STBER

Gr.1-Motor-2,5mm2 Gr.1-Motor-4,0mm
2

Stber iMDS5000 & iSDS4000 Basic cable


Gr.1,5-Motor-4,0mm2 Gr.1,5-Motor-6,0mm
2

MAT9420005 MAT9420006 MAT9420007

(4G4,0+2x(2x1,5)C)C (4G6,0+2x(2x1,5)C)C (4G10,0+2x(2x1,5)C)C

18,0 19,5 23,5

Gr.1,5-Motor-10,0mm2

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.342

(for up to 10 cuts of the same type)

Servo PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

G Colour: Pastel orange (similar to RAL 2003)

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.343

Power PVC

Chainflex-PVC Power cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Jet black (similar to RAL 9005)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Control Techniques Basic cable


PS B G A A XXX PS B A A A XXX PS B B A A XXX PS B G F A XXX PS B A F A XXX PS B B F A XXX MAT9560001 MAT9450002 MAT9560003 MAT9560004 MAT9560005 MAT9560006 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C 9,5 11,0 14,0 9,5 11,0 14,0

CONTROL TECHNIQUES

Control Techniques Basic cable


PS B G A B XXX PS B A A B XXX PS B B A B XXX PS B C A B XXX PS B D A B XXX PS B E A B XXX PS B G F B XXX PS B A F B XXX PS B B F B XXX PS B C F B XXX PS B D F B XXX PS B E F B XXX PS B G B B XXX PS B A B B XXX PS B B B B XXX PS B C B B XXX PS B D B B XXX PS B E B B XXX MAT9560007 MAT9560008 MAT9560009 MAT9560010 MAT9560011 MAT9560012 MAT9560013 MAT9560014 MAT9560015 MAT9560016 MAT9560017 MAT9560018 MAT9560019 MAT9560020 MAT9560021 MAT9560022 MAT9560023 MAT9560024 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C 9,5 11,0 14,0 15,5 19,5 22,0 9,5 11,0 14,0 15,5 19,5 22,0 9,5 11,0 14,0 15,5 19,5 22,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.344

(for up to 10 cuts of the same type)

Power PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Danaher Motion Basic cable


107485 (5 m) 107486 (10 m) 107487 (15 m) 107488 (20 m) 107489 (25 m) 107473 (5 m) 107474 (10 m) 107475 (15 m) 107476 (20 m) MAT9340002 MAT9340049 MAT9340050 MAT9340051 MAT9340052 MAT9340053 MAT9340054 MAT9340055 MAT9340056 MAT9340057 MAT9340058 MAT9340059 MAT9340060 MAT9340061 MAT9340062 MAT9340063 MAT9340064 MAT9340065 MAT9340066 MAT9340067 MAT9340068 MAT9340069 MAT9340070 MAT9340071 MAT9340072 (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5 10,5

DANAHER MOTION

107477 (25 m) 102575 (5 m) 102576 (10 m) 102806 (15 m) 102807 (20 m) 102808 (25 m) 90083 (5 m) 90084 (10 m) 90085 (15 m) 90086 (20 m) 90087 (25 m) 89918 (5 m) 89952 (10 m) 89953 (15 m) 89954 (20 m) 89956 (25 m)

Danaher Motion Basic cable


89959 (5 m) 89960 (10 m) 89962 (15 m) MAT9340004 MAT9340073 MAT9340074 (4 G 2,5)C (4 G 2,5)C (4 G 2,5)C 12,5 12,5 12,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.345

Power PVC

Chainflex-PVC Power cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Jet black (similar to RAL 9005)

Manufacturer Part No. 89964 (20 m) 89966 (25 m) 200456 (5 m) 200457 (10 m) 200458 (15 m) 200459 (20 m) 200460 (25 m) 200468 (5 m) 200469 (10 m) 200470 (15 m) 200471 (20 m) 200472 (25 m) 200618 (5 m) 200619 (10 m) 200620 (15 m) 200621 (20 m) 200622 (25 m)

igus Part No. MAT9340075 MAT9340076 MAT9340077 MAT9340078 MAT9340079 MAT9340080 MAT9340081 MAT9340082 MAT9340083 MAT9340084 MAT9340085 MAT9340086 MAT9340087 MAT9340088 MAT9340089 MAT9340090 MAT9340091

Number of cores and conductor nominal cross section [mm ]


2

mm 12,5 12,5 10,5 10,5 10,5 10,5 10,5 12,5 12,5 12,5 12,5 12,5 14,0 14,0 14,0 14,0 14,0

(4 G 2,5)C (4 G 2,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 2,5)C (4 G 2,5)C (4 G 2,5)C (4 G 2,5)C (4 G 2,5)C (4 G 4,0)C (4 G 4,0)C (4 G 4,0)C (4 G 4,0)C (4 G 4,0)C

DANAHER MOTION

NUM Basic cable


AGOFRU018LMxxx MAT9280051 MAT9280052 (4 G 1,5)C (4 G 4)C 10,5 14,0

NUM

AGOFRU019LMxxx

NUM Extension cable


AGOFRU018LMxxx AGOFRU019LMxxx MAT9280061 MAT9280062 (4 G 1,5)C (4 G 4)C 10,5 14,0

SEW

SEW Connection cable (Amphenol)


199 180 9 199 182 5 199 184 1 MAT9410006 MAT9410007 MAT9410008 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C 10,5 12,5 14,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.346

(for up to 10 cuts of the same type)

Power PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

Manufacturer Part No. 199 186 8 199 188 4

igus Part No. MAT9410009 MAT9410010

Number of cores and conductor nominal cross section [mm ]


2

mm 16,0 20,5

(4 G 6,0)C (4 G 10,0)C

SEW Extension cable (Amphenol)


199 550 2 199 552 9 MAT9411006 MAT9411007 MAT9411008 MAT9411009 MAT9411010 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C 10,5 12,5 14,0 16,0 20,5

SEW

199 554 5 199 556 1 199 558 8

SEW Connection cable (Amphenol)


0590 477 3 MAT9410012 (4 G 1,5)C 10,5

SEW Extension cable (Amphenol)


0590 361 0 MAT9411012 (4 G 1,5)C 9,5

Siemens Basic cable


6FX8002-5CA01 MAT9150001 MAT9150002 (4 G 1,5)C (4 G 2,5)C 12,5 15,0 3

SIEMENS

6FX8002-5CA11

Siemens Basic cable


6FX8002-5CA21 6FX8002-5CA31 6FX8002-5CA41 6FX8002-5CA51 6FX8002-5CA61 MAT9150003 MAT9150004 MAT9150005 MAT9150006 MAT9150007 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C 12,5 15,0 16,0 19,0 24,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.347

Power PVC

Chainflex-PVC Power cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Jet black (similar to RAL 9005)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Siemens Basic cable


6FX8002-5CA23 MAT9150008 (4 G 16,0)C 27,0

Siemens Basic cable


6FX8002-5CS01 6FX8002-5CS21 6FX8002-5CS31 MAT9150020 MAT9150021 MAT9150022 (4 G 1,5)C (4 G 1,5)C (4 G 2,5)C 10,5 10,5 12,5

SIEMENS

Siemens Extension cable


6FX8002-5CA05 6FX8002-5CA15 MAT9151001 MAT9151002 (4 G 1,5)C (4 G 2,5)C 12,5 15,0 3

Siemens Extension cable


6FX8002-5CA28 6FX8002-5CA38 6FX8002-5CA48 6FX8002-5CA58 6FX8002-5CA68 MAT9151003 MAT9151004 MAT9151005 MAT9151006 MAT9151007 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C 12,5 15,0 16,0 19,0 24,0

Siemens Extension cable


6FX8002-5CX28 MAT9151008 (4 G 16,0)C 27,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.348

(for up to 10 cuts of the same type)

Power PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.349

Power TPE

Chainflex-TPE Power cable


G G G G G Class 6.4.4 Oil-resistant Shielded Hydrolysis-resistant and microbe-resistant Flame-retardant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Control Techniques Basic cable


PS B G A A XXX PS B A A A XXX PS B B A A XXX PS B G F A XXX PS B A F A XXX PS B B F A XXX MAT9540001 MAT9540002 MAT9540003 MAT9540004 MAT9540005 MAT9540006 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C 9,5 11,0 14,0 9,5 11,0 14,0

CONTROL TECHNIQUES

Control Techniques Basic cable


PS B G A B XXX PS B A A B XXX PS B B A B XXX PS B C A B XXX PS B D A B XXX PS B E A B XXX PS B G F B XXX PS B A F B XXX PS B B F B XXX PS B C F B XXX PS B D F B XXX PS B E F B XXX PS B G B B XXX PS B A B B XXX PS B B B B XXX PS B C B B XXX PS B D B B XXX PS B E B B XXX MAT9540007 MAT9540008 MAT9540009 MAT9540010 MAT9540011 MAT9540012 MAT9540013 MAT9540014 MAT9540015 MAT9540016 MAT9540017 MAT9540018 MAT9540019 MAT9540020 MAT9540021 MAT9540022 MAT9540023 MAT9540024 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C (4 G 16,0)C 9,5 11,0 14,0 15,5 19,5 22,0 9,5 11,0 14,0 15,5 19,5 22,0 9,5 11,0 14,0 15,5 19,5 22,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.350

(for up to 10 cuts of the same type)

Power TPE

G Temperature range (moved): -35 C to + 90C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter G Colour: Jet black (similar to RAL 9005)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Danaher Motion Basic cable


107485 (5 m) 107486 (10 m) 107487 (15 m) 107488 (20 m) 107489 (25 m) 107473 (5 m) 107474 (10 m) 107475 (15 m) 107476 (20 m) MAT9440002 MAT9440049 MAT9440050 MAT9440051 MAT9440052 MAT9440053 MAT9440054 MAT9440055 MAT9440056 MAT9440057 MAT9440058 MAT9440059 MAT9440060 MAT9440061 MAT9440062 MAT9440063 MAT9440064 MAT9440065 MAT9440066 MAT9440067 MAT9440068 MAT9440069 MAT9440070 MAT9440071 MAT9440072 (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5

DANAHER MOTION

107477 (25 m) 102575 (5 m) 102576 (10 m) 102806 (15 m) 102807 (20 m) 102808 (25 m) 90083 (5 m) 90084 (10 m) 90085 (15 m) 90086 (20 m) 90087 (25 m) 89918 (5 m) 89952 (10 m) 89953 (15 m) 89954 (20 m) 89956 (25 m)

Danaher Motion Basic cable


89959 (5 m) 89960 (10 m) 89962 (15 m) MAT9440004 MAT9440073 MAT9440074 (4 G 2,5)C (4 G 2,5)C (4 G 2,5)C 11,0 11,0 11,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.351

Power TPE

Chainflex-TPE Power cable


G G G G G Class 6.4.4 Oil-resistant Shielded Hydrolysis-resistant and microbe-resistant Flame-retardant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No. 89964 (20 m) 89966 (25 m) 200456 (5 m) 200457 (10 m) 200458 (15 m) 200459 (20 m) 200460 (25 m) 200468 (5 m) 200469 (10 m) 200470 (15 m) 200471 (20 m) 200472 (25 m) 200618 (5 m) 200619 (10 m) 200620 (15 m) 200621 (20 m) 200622 (25 m)

igus Part No. MAT9440075 MAT9440076 MAT9440077 MAT9440078 MAT9440079 MAT9440080 MAT9440081 MAT9440082 MAT9440083 MAT9440084 MAT9440085 MAT9440086 MAT9440087 MAT9440088 MAT9440089 MAT9440090 MAT9440091

Number of cores and conductor nominal cross section [mm ]


2

mm 11,0 11,0 9,5 9,5 9,5 9,5 9,5 11,0 11,0 11,0 11,0 11,0 14,0 14,0 14,0 14,0 14,0

(4 G 2,5)C (4 G 2,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 1,5)C (4 G 2,5)C (4 G 2,5)C (4 G 2,5)C (4 G 2,5)C (4 G 2,5)C (4 G 4,0)C (4 G 4,0)C (4 G 4,0)C (4 G 4,0)C (4 G 4,0)C

DANAHER MOTION

NUM Basic cable


AGOFRU018LMxxx MAT9282051 MAT9282052 (4 G 1,5)C (4 G 4)C 9,5 14,0

NUM

AGOFRU019LMxxx

NUM Extension cable


AGOFRU018LMxxx AGOFRU019LMxxx MAT9282061 MAT9282062 (4 G 1,5)C (4 G 4)C 9,5 14,0

SEW

SEW Connection cable (Amphenol)


199 180 9 199 182 5 199 184 1 MAT9400006 MAT9400007 MAT9400008 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C 9,5 11,0 14,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.352

(for up to 10 cuts of the same type)

Power TPE

G Temperature range (moved): -35 C to + 90C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter G Colour: Jet black (similar to RAL 9005)

Manufacturer Part No. 199 186 8 199 188 4

igus Part No. MAT9400009 MAT9400010

Number of cores and conductor nominal cross section [mm ]


2

mm 15,5 19,5

(4 G 6,0)C (4 G 10,0)C

SEW Extension cable (Amphenol)


199 550 2 199 552 9 MAT9401006 MAT9401007 MAT9401008 MAT9401009 MAT9401010 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C 9,5 11,0 14,0 15,5 19,5

SEW

199 554 5 199 556 1 199 558 8

SEW Connection cable (Amphenol)


0590 477 3 MAT9400012 (4 G 1,5)C 9,5

SEW Extension cable (Amphenol)


0590 361 0 MAT9401012 (4 G 1,5)C 9,5

Siemens Basic cable


6FX8002-5CA01 MAT9050001 MAT9050002 (4 G 1,5)C (4 G 2,5)C 10,0 11,5

SIEMENS

6FX8002-5CA11

Siemens Basic cable


6FX8002-5CA21 6FX8002-5CA31 6FX8002-5CA41 6FX8002-5CA51 6FX8002-5CA61 MAT9050003 MAT9050004 MAT9050005 MAT9050006 MAT9050007 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C 10,0 11,5 13,0 15,0 20,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.353

Power TPE

Chainflex-TPE Power cable


G G G G G Class 6.4.4 Oil-resistant Shielded Hydrolysis-resistant and microbe-resistant Flame-retardant G Nominal voltage: 600/1000 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Siemens Basic cable


6FX8002-5CA23 MAT9050008 (4 G 16,0)C 22,0

Siemens Basic cable


6FX8002-5CS01 6FX8002-5CS21 6FX8002-5CS31 MAT9050020 MAT9050021 MAT9050022 (4 G 1,5)C (4 G 1,5)C (4 G 2,5)C 9,5 9,5 11,0

SIEMENS

Siemens Extension cable


6FX8002-5CA05 6FX8002-5CA15 MAT9051001 MAT9051002 (4 G 1,5)C (4 G 2,5)C 10,0 11,5

Siemens Extension cable


6FX8002-5CA28 6FX8002-5CA38 6FX8002-5CA48 6FX8002-5CA58 6FX8002-5CA68 MAT9051003 MAT9051004 MAT9051005 MAT9051006 MAT9051007 (4 G 1,5)C (4 G 2,5)C (4 G 4,0)C (4 G 6,0)C (4 G 10,0)C 10,0 11,5 13,0 15,0 20,0

Siemens Extension cable


6FX8002-5CX28 MAT9051008 (4 G 16,0)C 22,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.354

(for up to 10 cuts of the same type)

Power TPE

G Temperature range (moved): -35 C to + 90C G Minimum bending radius for use in Energy Chains: 7,5 x cable diameter G Colour: Jet black (similar to RAL 9005)

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.355

Data PVC

Chainflex-PVC Data cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 300/300 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Silver gray (similar to RAL 7001)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

B&R

B&R Basic cable


i8CRxxx.12-1 MAT9640001 (3 x (2 x 0,25))C 7,0

Beckhoff Basic cable


ZK4000-2610-xxxx MAT9381004 (8 x (2 x 0,25))C 11,5

Beckhoff Basic cable


ZK4510-0020-xxxx MAT9381001 (8 x (2 x 0,25))C 11,5

Beckhoff Basic cable


BECKHOFF
ZK4520-0020-xxxx MAT9381002 (6 x (2 x 0,25))C 9,5

Beckhoff Extension cable


ZK4511-0020-xxxx MAT9381003 (8 x (2 x 0,25))C 11,5

Beckhoff Basic cable


ZK4000-2210-xxxx MAT9383003 (4 x (2 x 0,25))C 8,0

Beckhoff Basic cable


ZK4530-0010-xxxx MAT9383001 (4 x (2 x 0,25))C 8,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.356

(for up to 10 cuts of the same type)

Data PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

BECKHOFF

Beckhoff Extension cable


ZK4531-0020-xxxx MAT9383002 (4 x (2 x 0,25))C 8,0

Danaher Motion Basic cable


84972 (5 m) 84973 (10 m) 84974 (15 m) 84975 (20 m) 87655 (25 m) 90287 (5 m) 91019 (10 m) 91811 (15 m) MAT9320001 MAT9320009 MAT9320010 MAT9320011 MAT9320012 MAT9320002 MAT9320013 MAT9320014 MAT9320015 MAT9320016 MAT9320004 MAT9320017 MAT9320018 MAT9320019 MAT9320020 (4 x (2 x 0,25))C (4 x (2 x 0,25))C (4 x (2 x 0,25))C (4 x (2 x 0,25))C (4 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C 8,0 8,0 8,0 8,0 8,0 11,5 11,5 11,5 11,5 11,5 11,5 11,5 11,5 11,5 11,5

DANAHER MOTION

91807 (20 m) 92205 (25 m) 107915 (5 m) 107916 (10 m) 107917 (15 m) 107918 (20 m) 107919 (25 m)

Danaher Motion Basic cable


85034 (5 m) 85035 (10 m) 85036 (15 m) 85037 (20 m) MAT9320007 MAT9320021 MAT9320022 MAT9320023 (6 x (2 x 0,25))C (6 x (2 x 0,25))C (6 x (2 x 0,25))C (6 x (2 x 0,25))C 9,5 9,5 9,5 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.357

Data PVC

Chainflex-PVC Data cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 300/300 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Silver gray (similar to RAL 7001)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

DANAHER MOTION

Danaher Motion Basic cable


85039 (5 m) 85040 (10 m) 85041 (15 m) 85042 (20 m) MAT9320008 MAT9320024 MAT9320025 MAT9320026 (6 x (2 x 0,25))C (6 x (2 x 0,25))C (6 x (2 x 0,25))C (6 x (2 x 0,25))C 9,5 9,5 9,5 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.358

(for up to 10 cuts of the same type)

Data PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.359

Measuring PVC

Chainflex-PVC Measuring system cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Silver gray (similar to RAL 7001)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

B&R

B&R Basic cable


i8CExxx.12-1 MAT9670001 (5x(2x0,14)+2x0,5)C 9,0

Baumller SRS/SRM50 & SKS/SKM36 Basic cable


246658 (3 m) 243379 (4 m) 239540 (5 m) 242954 (6 m) 239541 (8 m) 239542 (10 m) 239543 (15 m) 239544 (20 m) 239545 (25 m) MAT9290001 MAT9290002 MAT9290003 MAT9290004 MAT9290005 MAT9290006 MAT9290007 MAT9290008 MAT9290009 MAT9290010 MAT9290011 MAT9290012 MAT9290013 MAT9290014 MAT9290015 MAT9290016 (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0

BAUMLLER

239546 (30 m) 239547 (35 m) 240520 (40 m) 240521 (45 m) 240522 (50 m) 244033 (55 m) 245484 (60 m)

Baumller SRS/SRM50 & SKS/SKM36 Extension cable


MAT9292001 (5x(2x0,14)+2x0,5)C 9,0

Baumller Basic cable*


198962 (3 m) 198963 (5 m) MAT9290020 MAT9290021 (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C 9,0 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.360

(for up to 10 cuts of the same type)

Measuring PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

Manufacturer Part No. 198964 (8 m) 198965 (10 m) 198966 (15 m) 198967 (10 m) 198968 (25 m) 198969 (30 m) 225360 (35 m) 208829 (40 m)

igus Part No. MAT9290022 MAT9290023 MAT9290024 MAT9290025 MAT9290026 MAT9290027 MAT9290028 MAT9290029

Number of cores and conductor nominal cross section [mm ]


2

mm 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0

(5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C

Baumller Extension cable


MAT9292020 (5x(2x0,14)+2x0,5)C 9,0

BAUMLLER

Baumller ECN1313/EQN1325 Basic cable


393889 (2m) 369864 (3m) 394014 (5 m) 389807 (7 m) 393890 (8 m) 389808 (9m) 393891 (10 m) 393892 (15 m) 371494 (20 m) 393893 (25 m) 393894 (30 m) 380358 (35 m) 391216 (40 m) 382005 (45 m) 378022 (50 m) MAT9290030 MAT9290031 MAT9290032 MAT9290033 MAT9290034 MAT9290035 MAT9290036 MAT9290037 MAT9290038 MAT9290039 MAT9290040 MAT9290041 MAT9290042 MAT9290043 MAT9290044 (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.361

Measuring PVC

Chainflex-PVC Measuring system cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Silver gray (similar to RAL 7001)

Manufacturer

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

BAUMLLER

Part No.

Baumller ECN1313/EQN1325 Extension cable


MAT9292030 (5x(2x0,14)+2x0,5)C 9,0

CONTROL TECHN. BERGER L.

Berger Lahr Basic cable


VW3M8101Rxxx MAT94603001 (4x(2x0,34)+4x0,5)C 9,0

Control Techniques Basic cable


SS B A H C XXX SS B A H H XXX SS B A H N XXX MAT9560100 MAT9560101 MAT9560104 (4x(2x0,34)+4x0,5)C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+ (4x0,14)+(2x0,5))C 10,5 10,5 10,5

ELAU Basic cable


ELAU
E-FB-060 E-FB-071 MAT9480001 MAT9480002 (4x(2x0,25)+2x0,5)c (4x(2x0,25)+2x0,5)c 9,0 9,0

ELAU Basic cable


E-FB-080 MAT9480003 (4x(2x0,25)+2x0,5)c 9,0

LENZE

Lenze Basic cable


EWLRxxxGM-T MAT9130021 (3x(2x0,14)C+(2x0,5C))C 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.362

(for up to 10 cuts of the same type)

Measuring PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Lenze Linking cable


EWLRxxxZMST MAT9130022 (3x(2x0,14)C+(2x0,5C))C 9,0

Lenze Terminal box connection cable*


EWLRxxxGX-T MAT9130023 (3x(2x0,14)C+(2x0,5C))C 9,0

Lenze Basic cable


EWLExxxGM-T MAT9130026 (4x(2x0,25)+2x1,0)C 9,5

LENZE

Lenze Linking cable


EWLExxxZMST MAT9130027 (4x(2x0,25)+2x1,0)C 9,5

Lenze Terminal box connection cable*


EWLExxxGX-T MAT9130028 (4x(2x0,25)+(2x1,0))C 9,5

Lenze Basic cable*


EYF0020VxxxxA00G01 EYF0019VxxxxA00G02 EYF0022VxxxxA00G03 MAT9130080 MAT9130081 MAT9130082 3(2x0,14)C+(3x0,14)C 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(4x0,14)C+2(2x0,5)C 9,5 11,0 11,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.363

Measuring PVC

Chainflex-PVC Measuring system cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Silver gray (similar to RAL 7001)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Lenze Basic cable


EYF0021AxxxxF03S03 EYF0018AxxxxF02S03 EYF0020AxxxxF01S05 MAT9130086 MAT9130088 MAT9130090 3(2x0,14)C+(4x0,14)C+2(2x0,5)C 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(3x0,14)C 11,0 11,0 9,5

Lenze Basic cable


EYF0018AxxxxF02W02 EYF0020AxxxxF01S04 MAT9130087 MAT9130089 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(3x0,14)C 11,0 9,5

LENZE

Lenze Basic cable*


EYF0018AxxxxA00W02 EYF0020AxxxxA00S04 MAT9130091 MAT9130092 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(3x0,14)C 11,0 9,5

Lenze Basic cable*


EYF0020AxxxxA00S05 EYF0021AxxxxA00S03 EYF0018AxxxxA00S03 MAT9130093 MAT9130094 MAT9130095 3(2x0,14)C+(3x0,14)C 3(2x0,14)C+(4x0,14)C+2(2x0,5)C 4(2x0,14)C+(2x1,0)C 9,5 11,0 11,0

Lenze Linking cable


EYF0020VxxxxF01G01 EYF0019VxxxxF02G02 EYF0022VxxxxF03G03 MAT9130083 MAT9130084 MAT9130085 3(2x0,14)C+(3x0,14)C 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(4x0,14)C+2(2x0,5)C 9,5 11,0 11,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.364

(for up to 10 cuts of the same type)

Measuring PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Lenze Connecting cable


EYD0017AxxxxW01S01 MAT9130100 3(2x0,14)C+(3x0,14)C 9,5

LENZE

Lenze Connecting cable


EYD0017AxxxxW01S02 MAT9130101 3(2x0,14)C+(3x0,14)C 9,5

Lenze Connecting cable


EYD0017AxxxxW03S01 MAT9130102 3(2x0,14)C+(3x0,14)C 9,5

Lenze Connecting cable


EYD0017AxxxxW03S02 MAT9130103 3(2x0,14)C+(3x0,14)C 9,5

NUM Basic cable


AGOFRU029Mxxx MAT9284001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0

NUM

NUM Extension cable


AGOFRU029Mxxx MAT9284011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0

NUM Basic cable*


AGOFRU030Mxxx MAT9289001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.365

Measuring PVC

Chainflex-PVC Measuring system cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Silver gray (similar to RAL 7001)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

NUM

NUM Extension cable


AGOFRU030Mxxx MAT9289011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0

Rexroth Basic cable


IKS0230 IKS0301 IKS0315 IKS0374 IKS4001 IKS4002 IKS4020 IKS4038 IKS4041 IKS4042 IKS4066 IKS4103 IKS4142 IKS4314 IKS4374 IKS4375 IKS4384 IKS4389 MAT9110008 MAT9110015 MAT9110020 MAT9110011 MAT9110026 MAT9110010 MAT9110006 MAT9110027 MAT9110028 MAT9110017 MAT9110025 MAT9110001 MAT9110007 MAT9110004 MAT9110002 MAT9110003 MAT9110005 MAT9110033 (2x(2x0,25)+2x0,5)C (4x(2x0,25)+2x1,0)C (4x(2x0,25)+2x1,0)C (4x(2x0,25)+2x1,0)C (4x2x0,14+4x1,0+(4x0,14)C)C (3x0,25+3x(2x0,25)C+2x1,0)C (4x2x0,14+4x1,0+(4x0,14)C)C (4x2x0,14+4x1,0+(4x0,14)C)C (3x0,25+3x(2x0,25)C+2x1,0)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x2x0,14+4x1,0+(4x0,14)C)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (3x0,25+3x(2x0,25)C+2x1,0)C (3x0,25+3x(2x0,25)C+2x1,0)C 7,0 9,5 9,5 9,5 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0 9,0

REXROTH

Rexroth Basic cable


RKG0014 RKG0020 RKG0026 RKG0028 RKG4200 MAT9110030 MAT9110034 MAT9110029 MAT9110031 MAT9110013 (3x0,25+3x(2x0,25)C+2x1,0)C (4x(2x0,25)+2x0,5)C (3x0,25+3x(2x0,25)C+2x1,0)C (3x0,25+3x(2x0,25)C+2x1,0)C (4x(2x0,25)+2x0,5)C 9,0 9,5 9,0 9,0 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.366

(for up to 10 cuts of the same type)

Measuring PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Rexroth Connecting cable with adapter plugs


REXROTH
IKS0232 IKS0303 IKS4065 IKS4151 IKS4153 IKS4376 IKS4322 MAT9110009 MAT9110019 MAT9111001 MAT9111002 MAT9111003 MAT9111004 MAT9111005 (2x(2x0,25)+2x0,5)C (4x(2x0,25)+2x1,0)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C 7,0 9,5 9,0 9,0 9,0 9,0 9,0

Rexroth Connecting cable with adapter plugs


RKG4201 MAT9111006 (4x(2x0,25)+2x0,5)C 9,5

SEW Connection cable


1332 455 1 1332 743 7 198 930 8 199 319 4 MAT9510003 MAT9510002 MAT9510004 MAT9510001 (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C 9,5 9,5 9,5 9,5

SEW

SEW Extension cable


199 541 3 199 540 5 0593 968 2 MAT9511001 MAT9511002 MAT9511003 (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C 9,5 9,5 9,5

SIEMENS

Siemens Basic cable


6FX8002-2AD00 MAT9170001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.367

Measuring PVC

Chainflex-PVC Measuring system cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Silver gray (similar to RAL 7001)

Manufacturer Part No. 6FX8002-2CA11 6FX8002-2CA15

igus Part No. MAT9170002 MAT9170003

Number of cores and conductor nominal cross section [mm ]


2

mm 9,0 9,0

(4x(2x0,34)+4x0,5)C (3x(2x0,14)C+(4x0,14)+(2x0,5))C

Siemens Basic cable


6FX8002-2CA31 MAT9170004 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,5

Siemens Basic cable


6FX8002-2CA51 6FX8002-2CA71 6FX8002-2CB51 6FX8002-2CC11 6FX8002-2CD01 MAT9170005 MAT9170006 MAT9170008 MAT9170009 MAT9170010 (3x(2x0,14)C+(4x0,14)+(2x0,5))C (4x(2x0,34)+4x0,5)C (4x(2x0,34)+4x0,5)C (4x(2x0,34)+4x0,5)C (4x(2x0,34)+4x0,5)C 9,0 9,0 9,0 9,0 9,0

SIEMENS

Siemens Basic cable


6FX8002-2CF01 6FX8002-2CF02 6FX8002-2CG00 MAT9170021 MAT9170011 MAT9170012 (3x(2x0,14)C+(4x0,14)+(2x0,5))C (3x(2x0,14)C+(4x0,14)+(2x0,5))C (4x(2x0,34)+4x0,5)C 9,0 9,0 9,0

Siemens Basic cable


6FX8002-2CH00 MAT9170013 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 9,0

Siemens Basic cable


6FX8002-2CK00 6FX8002-2CL00 MAT9170014 MAT9170015 (3x(2x0,14)C+(2x0,5C))C (3x(2x0,14)C+(2x0,5C))C 9,0 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.368

(for up to 10 cuts of the same type)

Measuring PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Siemens Basic cable


6FX8002-2EQ00 MAT9170016 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,5

Siemens Basic cable


6FX8002-2EQ10 MAT9170017 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 9,5

SIEMENS

Siemens Basic cable*


6FX8002-2AH00 MAT9170018 (4x(2x0,34)+4x0,5)C 9,0

Siemens Extension cable


6FX8002-2AD04 6FX8002-2CB54 6FX8002-2CA54 6FX8002-2CA34 6FX8002-2CC14 6FX8002-2CF04 6FX8002-2EQ14 6FX8002-2AH04 MAT9171001 MAT9171002 MAT9171003 MAT9171004 MAT9171009 MAT9171011 MAT9171017 MAT9171018 (3x(2x0,14)C+(4x0,14)+(2x0,5))C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+(4x0,14)+(2x0,5))C (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+(4x0,14)+(2x0,5))C (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C (4x(2x0,34)+4x0,5)C 9,0 9,0 9,0 9,5 9,0 9,0 9,5 9,0

STBER

Stber iMDS5000 Basic cable


Resolver MAT9431005 (3x(2x0,25))C 11,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.369

Measuring PVC

Chainflex-PVC Measuring system cable


G G G G G Class 5.3.2 Oil-resistant Shielded Flame-retardant Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical G Colour: Silver gray (similar to RAL 7001)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Stber iMDS5000 Basic cable


STBER
Encoder MAT9431004 (4x(2x0,25)+(2x0,5))C 9,0

Stber iSDS4000 Basic cable


Resolver MAT9431003 (4x(2x0,25)+(2x0,5))C 9,0

Stber iSDS4000 Basic cable


Encoder ED/EK MAT9431001 (4x(2x0,34)+(4x0,5))C 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.370

(for up to 10 cuts of the same type)

Measuring PVC

G Temperature range (moved): -5 C to + 70C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.371

Data PUR

Chainflex-PUR Data cable


G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 300/300 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Beckhoff Basic cable


ZK4000-2610-xxxx MAT9382004 (8 x (2 x 0,25))C 11,0

Beckhoff Basic cable


ZK4510-0020-xxxx MAT9382001 (8 x (2 x 0,25))C 11,0

Beckhoff Basic cable


BECKHOFF
ZK4520-0020-xxxx MAT9382002 (6 x (2 x 0,25))C 10,0

Beckhoff Extension cable


ZK4511-0020-xxxx MAT9382003 (8 x (2 x 0,25))C 11,0

Beckhoff Basic cable


ZK4000-2210-xxxx MAT9384003 (4 x (2 x 0,25))C 9,0

Beckhoff Basic cable


ZK4530-0010-xxxx MAT9384001 (4 x (2 x 0,25))C 9,0

Beckhoff Extension cable


ZK4531-0020-xxxx MAT9384002 (4 x (2 x 0,25))C 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.372

(for up to 10 cuts of the same type)

Data PUR

G Flame-retardant G Temperature range (moved): -35 C to + 80C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

G Colour: Anthracite gray (similar to RAL 7016)

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.373

Measuring PUR

Chainflex-PUR Measuring system cable


G G G G Class 6.3.3 Oil-resistant and coolant-resistant Shielded Notch-resistant, hydrolysis-resistant and microbe-resistant G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Heidenhain Connecting cable


332 115-xx MAT94901001 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0

Heidenhain Connecting cable


360 472-xx MAT94901002 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0

Heidenhain Connecting cable


HEIDENHAIN
310 197-xx MAT94902001 (3x(2x0,14)C+(2x0,5)C)C 12,0

Heidenhain Connecting cable


324 544-xx 310 199-xx MAT94902002 MAT94902003 (4x(2x0,14)+(4x0,14)C+4x0,5)C (4x(2x0,14)+4x0,5)C 12,0 10,0

Heidenhain Connecting cable


309 738-xx MAT94903001 (4x(2x0,14)+4x0,5)C 10,0

Heidenhain Connecting cable


354 411-xx 355 398-xx MAT94904001 MAT94904002 (4x(2x0,14)+(4x0,14)C+4x0,5)C (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0 12,0

Heidenhain Connecting cable

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.374

(for up to 10 cuts of the same type)

Measuring PUR

G Flame-retardant G Temperature range (moved): -20 C to + 80C G Minimum bending radius for use in Energy Chains: 10 x cable diameter

G Colour: Yellow green (similar to RAL 6018)

Manufacturer Part No. 298 399-xx

igus Part No. MAT94905001

Number of cores and conductor nominal cross section [mm ]


2

mm 10,0

(4x(2x0,14)+4x0,5)C

Heidenhain Connecting cable


309 774-xx 298 400-xx 323 897-xx MAT94906001 MAT94906002 MAT94907004 (4x(2x0,14)+4x0,5)C (4x(2x0,14)+4x0,5)C (4x(2x0,14)+ (4x0,14)C+4x0,5)C 10,0 10,0 12,0

HEIDENHAIN

Heidenhain Connecting cable


309 777-xx 309 778-xx MAT94907001 MAT94907002 (4x(2x0,14)+4x0,5)C (4x(2x0,14)+(4x0,14)C+4x0,5)C 10,0 12,0

Heidenhain Connecting cable


310 193-xx MAT94907003 (3x(2x0,14)C+(2x0,5)C)C 12,0

Heidenhain Connecting cable


335 077-xx MAT94908001 (4x(2x0,14)+4x0,5)C 10,0

Heidenhain Connecting cable


298 402-xx MAT94909001 (4x(2x0,14)+4x0,5)C 10,0

SIEMENS

Siemens Basic cable


6FX8002-2DC10 6FX8002-2DC20 6FX8002-1DC00 MAT9070030 MAT9070031 MAT9070032 (2x(2x0,15)+(2x0,38))C (2x(2x0,15)+(2x0,38))C (2x(2x0,15)+(2x0,38))C 7,5 7,5 7,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.375

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G G Class 4.1.4 Oil-resistant Shielded Hydrolysis-resistant and microbe-resistant Flame-retardant G Nominal voltage: 30 V G Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Fanuc Basic cable


LX660-4077-T296 MAT9300296 (5x0,5+1x2x0,25)C 7,5

Fanuc Basic cable


FANUC
LX660-4077-T297 MAT9300297 (5x0,5+1x2x0,25)C 7,5

Fanuc Basic cable


LX660-4077-T302 MAT9300302 ((6x0,5)+5x(2x0,25))C 9,6

Fanuc Basic cable


LX660-4077-T303 MAT9300303 ((6x0,5)+5x(2x0,25))C 9,6

Fanuc Basic cable


LX660-4077-T319 MAT9300319 (6x0,5+5x2x0,25)C 9,6

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.376

(for up to 10 cuts of the same type)

Measuring TPE

G Temperature range (moved): -35 C to + 100C G Minimum bending radius for use in Energy Chains: 12 x cable diameter G Colour: Yellow green (similar to RAL 6018)

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.377

Data TPE

Chainflex-TPE Data cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 300/300 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

B&R

B&R Basic cable


i8CRxxx.12-1 MAT9630001 (3 x (2 x 0,25))C 8,0

Danaher Motion Basic cable


84972 (5 m) 84973 (10 m) 84974 (15 m) 84975 (20 m) 87655 (25 m) 90287 (5 m) 91019 (10 m) 91811 (15 m) MAT9330001 MAT9330009 MAT9330010 MAT9330011 MAT9330012 MAT9330002 MAT9330013 MAT9330014 MAT9330015 MAT9330016 MAT9330004 MAT9330017 MAT9330018 MAT9330019 MAT9330020 (4 x (2 x 0,25))C (4 x (2 x 0,25))C (4 x (2 x 0,25))C (4 x (2 x 0,25))C (4 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C (8 x (2 x 0,25))C 8,0 8,0 8,0 8,0 8,0 11,5 11,5 11,5 11,5 11,5 11,5 11,5 11,5 11,5 11,5

DANAHER MOTION

91807 (20 m) 92205 (25 m) 107915 (5 m) 107916 (10 m) 107917 (15 m) 107918 (20 m) 107919 (25 m)

Danaher Motion Basic cable


85034 (5 m) 85035 (10 m) 85036 (15 m) 85037 (20 m) MAT9330007 MAT9330021 MAT9330022 MAT9330023 (6 x (2 x 0,25))C (6 x (2 x 0,25))C (6 x (2 x 0,25))C (6 x (2 x 0,25))C 9,5 9,5 9,5 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.378

(for up to 10 cuts of the same type)

Data TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Steel blue (similar to RAL 5011)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

DANAHER MOTION

Danaher Motion Basic cable


85039 (5 m) 85040 (10 m) 85041 (15 m) 85042 (20 m) MAT9330008 MAT9330024 MAT9330025 MAT9330026 (6 x (2 x 0,25))C (6 x (2 x 0,25))C (6 x (2 x 0,25))C (6 x (2 x 0,25))C 9,5 9,5 9,5 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.379

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

B&R

B&R Basic cable


i8CExxx.12-1 MAT9660001 (5x(2x0,14)+2x0,5)C 9,5

Baumller SRS/SRM50 & SKS/SKM36 Basic cable


246658 (3 m) 243379 (4 m) 239540 (5 m) 242954 (6 m) 239541 (8 m) 239542 (10 m) 239543 (15 m) 239544 (20 m) 239545 (25 m) MAT9291001 MAT9291002 MAT9291003 MAT9291004 MAT9291005 MAT9291006 MAT9291007 MAT9291008 MAT9291009 MAT9291010 MAT9291011 MAT9291012 MAT9291013 MAT9291014 MAT9291015 MAT9291016 (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5

BAUMLLER

239546 (30 m) 239547 (35 m) 240520 (40 m) 240521 (45 m) 240522 (50 m) 244033 (55 m) 245484 (60 m)

Baumller SRS/SRM50 & SKS/SKM36 Extension cable


MAT9293001 (5x(2x0,14)+2x0,5)C 9,5

Baumller Basic cable*


198962 (3 m) 198963 (5 m) MAT9291020 MAT9291021 (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C 9,5 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.380

(for up to 10 cuts of the same type)

Measuring TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Yellow green (similar to RAL 6018)

Manufacturer Part No. 198964 (8 m) 198965 (10 m) 198966 (15 m) 198967 (10 m) 198968 (25 m) 198969 (30 m) 225360 (35 m) 208829 (40 m)

igus Part No. MAT9291022 MAT9291023 MAT9291024 MAT9291025 MAT9291026 MAT9291027 MAT9291028 MAT9291029

Number of cores and conductor nominal cross section [mm ]


2

mm 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5

(5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C

Baumller Extension cable


MAT9293020 (5x(2x0,14)+2x0,5)C 9,5

BAUMLLER

Baumller ECN1313/EQN1325 Basic cable


393889 (2 m) 369864 (3 m) 394014 (5 m) 389807 (7 m) 393890 (8 m) 389808 (9 m) 393891 (10 m) 393892 (15 m) 371494 (20 m) 393893 (25 m) 393894 (30 m) 380358 (35 m) 391216 (40 m) 382005 (45 m) 378022 (50 m) MAT9291030 MAT9291031 MAT9291032 MAT9291033 MAT9291034 MAT9291035 MAT9291036 MAT9291037 MAT9291038 MAT9291039 MAT9291040 MAT9291041 MAT9291042 MAT9291043 MAT9291044 (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C (5x(2x0,14)+2x0,5)C 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.381

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

BAUMLLER

Part No.

Baumller ECN1313/EQN1325 Extension cable


MAT9293030 (5x(2x0,14)+2x0,5)C 9,5

CONTROL TECHN. BERGER L.

Berger Lahr Basic cable


VW3M8101Rxxx MAT94600001 (4x(2x0,34)+4x0,5)C 10,5

Control Techniques Basic cable


SS B A H C XXX SS B A H H XXX SS B A H N XXX MAT9540100 MAT9540101 MAT9540104 (4x(2x0,34)+4x0,5)C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+ (4x0,14)+(2x0,5))C 10,5 10,5 10,5

ELAU Basic cable


ELAU
E-FB-060 E-FB-071 MAT9480101 MAT9480102 (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C 9,5 9,5

ELAU Basic cable


E-FB-080 MAT9480103 (4x(2x0,25)+2x0,5)C 9,5

FAGOR

Fagor Extension cable


iXC-C2-D MAT9520001 (4x(2x0,14)+4x0,5)C 9,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.382

(for up to 10 cuts of the same type)

Measuring TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Yellow green (similar to RAL 6018)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Fagor Extension cable


iXC-C4-D MAT9520010 (4x(2x0,14)+4x0,5)C 9,0

Fagor Extension cable


iXC-C2-H MAT9520020 (4x(2x0,14)+4x0,5)C 9,0

FAGOR

Fagor Extension cable


iXC-C8-F-D MAT9520030 (4x(2x0,14)+ (4x0,14)C+4x0,5)C 12,0

Fagor Extension cable


iXC-C8-F-C9 MAT9520040 (4x(2x0,14)+ (4x0,14)C+4x0,5)C 12,0

Fagor Extension cable


iXC-C8-FN MAT9520050 (4x(2x0,14)+4x0,5)C 9,0

Fagor Extension cable


iXC-C2-FN2 MAT9520060 (4x(2x0,14)+4x0,5)C 9,0

FANUC

Fanuc Basic cable


LX660-4077-T296 MAT9310296 (5x0,5+1x2x0,25)C 8,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.383

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Fanuc Basic cable


LX660-4077-T297 MAT9310297 (5x0,5+1x2x0,25)C 8,5

FANUC

Fanuc Basic cable


LX660-4077-T302 MAT9310302 ((6x0,5)+5x(2x0,25))C 12,5

Fanuc Basic cable


LX660-4077-T303 MAT9310303 ((6x0,5)+5x(2x0,25))C 12,5

Fanuc Basic cable


LX660-4077-T319 MAT9310319 (6x0,5+5x2x0,25)C 12,5

Heidenhain Connecting cable


332 115 -xx MAT93901001 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0

HEIDENHAIN

Heidenhain Connecting cable


360 472-xx MAT93901002 (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0

Heidenhain Connecting cable


310 197-xx MAT93902001 (3x(2x0,14)C+(2x0,5)C)C 12,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.384

(for up to 10 cuts of the same type)

Measuring TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Yellow green (similar to RAL 6018)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Heidenhain Connecting cable


324 544-xx 310 199-xx MAT93902002 MAT93902003 (4x(2x0,14)+(4x0,14)C+4x0,5)C (4x(2x0,14)+4x0,5)C 12,0 9,0

Heidenhain Connecting cable


309 738-xx MAT93903001 (4x(2x0,14)+4x0,5)C 9,0

Heidenhain Connecting cable


HEIDENHAIN
354 411-xx 355 398-xx MAT93904001 MAT93904002 (4x(2x0,14)+(4x0,14)C+4x0,5)C (4x(2x0,14)+(4x0,14)C+4x0,5)C 12,0 12,0

Heidenhain Connecting cable


298 399-xx MAT93905001 (4x(2x0,14)+4x0,5)C 9,0

Heidenhain Connecting cable


309 774-xx 298 400-xx 323 897-xx MAT93906001 MAT93906002 MAT93907004 (4x(2x0,14)+4x0,5)C (4x(2x0,14)+4x0,5)C (4x(2x0,14)+ (4x0,14)C+4x0,5)C 9,0 9,0 12,0

Heidenhain Connecting cable


309 777-xx 309 778-xx MAT93907001 MAT93907002 (4x(2x0,14)+4x0,5)C (4x(2x0,14)+(4x0,14)C+4x0,5)C 9,0 12,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.385

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Heidenhain Connecting cable


HEIDENHAIN
310 193-xx MAT93907003 (3x(2x0,14)C+(2x0,5)C)C 12,5

Heidenhain Connecting cable


335 077-xx MAT93908001 (4x(2x0,14)+4x0,5)C 10,0

Heidenhain Connecting cable


298 402-xx MAT93909001 (4x(2x0,14)+4x0,5)C 9,0

Lenze Basic cable


EWLRxxxGM-T MAT9120021 (3x(2x0,14)C+(2x0,5C))C 12,5

Lenze Linking cable


LENZE
EWLRxxxZMST MAT9120022 (3x(2x0,14)C+2x0,5)C 12,5

Lenze Terminal box connection cable*


EWLRxxxGX-T MAT9120023 (3x(2x0,14)C+2x0,5)C 12,5

Lenze Basic cable


EWLExxxGM-T MAT9120026 (4x(2x0,25)+2x1,0)C 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.386

(for up to 10 cuts of the same type)

Measuring TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Yellow green (similar to RAL 6018)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Lenze Linking cable


EWLExxxZMST MAT9120027 (4x(2x0,25)+2x1,0)C 9,5

Lenze Terminal box connection cable*


EWLExxxGX-T MAT9120028 (4x(2x0,25)+(2x1,0))C 9,5

Lenze Basic cable*


EYF0020VxxxxA00G01 MAT9120080 MAT9120081 MAT9120082 3(2x0,14)C+(3x0,14)C 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(4x0,14)C+2(2x0,5)C 9,5 11,0 12,0

LENZE

EYF0019VxxxxA00G02 EYF0022VxxxxA00G03

Lenze Basic cable


EYF0021AxxxxF03S03 EYF0018AxxxxF02S03 EYF0020AxxxxF01S05 MAT9120086 MAT9120088 MAT9120090 3(2x0,14)C+(4x0,14)C+2(2x0,5)C 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(3x0,14)C 12,0 11,0 9,5

Lenze Basic cable


EYF0018AxxxxF02W02 EYF0020AxxxxF01S04 MAT9120087 MAT9120089 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(3x0,14)C 11,0 9,5

Lenze Basic cable*


EYF0018AxxxxA00W02 EYF0020AxxxxA00S04 MAT9120091 MAT9120092 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(3x0,14)C 11,0 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.387

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Lenze Basic cable*


EYF0020AxxxxA00S05 EYF0021AxxxxA00S03 EYF0018AxxxxA00S03 MAT9120093 MAT9120094 MAT9120095 3(2x0,14)C+(3x0,14)C 3(2x0,14)C+(4x0,14)C+2(2x0,5)C 4(2x0,14)C+(2x1,0)C 9,5 12,0 11,0

Lenze Linking cable


EYF0020VxxxxF01G01 EYF0019VxxxxF02G02 EYF0022VxxxxF03G03 MAT9120083 MAT9120084 MAT9120085 3(2x0,14)C+(3x0,14)C 4(2x0,14)C+(2x1,0)C 3(2x0,14)C+(4x0,14)C+2(2x0,5)C 9,5 11,0 12,0

LENZE

Lenze Connecting cable


EYD0017AxxxxW01S01 MAT9120100 3(2x0,14)C+(3x0,14)C 9,5

Lenze Connecting cable


EYD0017AxxxxW01S02 MAT9120101 3(2x0,14)C+(3x0,14)C 9,5

Lenze Connecting cable


EYD0017AxxxxW03S01 MAT9120102 3(2x0,14)C+(3x0,14)C 9,5

Lenze Connecting cable


EYD0017AxxxxW03S02 MAT9120103 3(2x0,14)C+(3x0,14)C 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.388

(for up to 10 cuts of the same type)

Measuring TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Yellow green (similar to RAL 6018)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

NUM Basic cable


AGOFRU029Mxxx MAT9286001 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5

NUM

NUM Extension cable


AGOFRU029Mxxx MAT9286011 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5

NUM Basic cable*


AGOFRU030Mxxx MAT9289004 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5

NUM Extension cable


AGOFRU030Mxxx MAT9289014 (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5 1

Rexroth Basic cable


IKS0230 IKS0251 MAT9100008 MAT9100014(8) MAT9100023(8) MAT9100032(8) MAT9100016 MAT9100015 MAT9100020 MAT9100011 MAT9100026 MAT9100010 MAT9100006 MAT9100027
(8)

(2x(2x0,25)+2x0,5)C (12x0,5)C (12x0,5)C (12x0,5)C (12x0,5)C (4x(2x0,25)+2x1,0)C (4x(2x0,25)+2x1,0)C (4x(2x0,25)+2x1,0)C (4x2x0,14+4x1,0+(4x0,14)C)C (3x0,25+3x(2x0,25)C+2x1,0)C (4x2x0,14+4x1,0+(4x0,14)C)C (4x2x0,14+4x1,0+(4x0,14)C)C

7,0 11,5 11,5 11,5 11,5 9,5 9,5 9,5 9,0 9,0 9,0 9,0

REXROTH

IKS0253 IKS0259 IKS0262 IKS0301 IKS0315 IKS0374 IKS4001 IKS4002 IKS4020 IKS4038

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. (8) ohne DESINA G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.389

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No. IKS4041 IKS4042 IKS4066 IKS4103 IKS4142 IKS4314 IKS4374 IKS4375 IKS4384 IKS4389

igus Part No. MAT9100028 MAT9100017 MAT9100025 MAT9100001 MAT9100007 MAT9100004 MAT9100002 MAT9100003 MAT9100005 MAT9100033

Number of cores and conductor nominal cross section [mm ]


2

mm 9,0 9,0 9,0 9,5 9,0 9,5 9,5 9,5 9,0 9,0

(3x0,25+3x(2x0,25)C+2x1,0)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x2x0,14+4x1,0+(4x0,14)C)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (3x0,25+3x(2x0,25)C+2x1,0)C (3x0,25+3x(2x0,25)C+2x1,0)C

Rexroth Basic cable


REXROTH
RKG0014 RKG0020 RKG0026 RKG0028 RKG4200 MAT9100030 MAT9100034 MAT9100029 MAT9100031 MAT9100013 (3x0,25+3x(2x0,25)C+2x1,0)C (4x(2x0,25)+2x0,5)C (3x0,25+3x(2x0,25)C+2x1,0)C (3x0,25+3x(2x0,25)C+2x1,0)C (4x(2x0,25)+2x0,5)C 9,0 9,5 9,0 9,0 9,5

Rexroth Connecting cable with adapter plugs


IKS0232 IKS0255 IKS0303 IKS4065 IKS4151 IKS4153 IKS4322 IKS4376 MAT9100009 MAT9100018 MAT9100019 MAT9101001 MAT9101002 MAT9101003 MAT9101005 MAT9101004
(8)

(2x(2x0,25)+2x0,5)C (12x0,5)C (4x(2x0,25)+2x1,0)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C (4x(2x0,25)+2x0,5)C

7,0 11,5 9,5 9,5 9,5 9,5 9,5 9,5

Rexroth Connecting cable with adapter plugs


RKG4201 MAT9101006 (4x(2x0,25)+2x0,5)C 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. (8) ohne DESINA G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.390

(for up to 10 cuts of the same type)

Measuring TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Yellow green (similar to RAL 6018)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

SEW Connection cable


1332 455 1 MAT9500003 MAT9500002 MAT9500004 MAT9500001 (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C 9,0 9,0 9,0 9,0

SEW

1332 743 7 198 930 8 199 319 4

SEW Extension cable


199 541 3 199 540 5 0593 968 2 MAT9501001 MAT9501002 MAT9501003 (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C (4x(2x0,25)+(2x0,5))C 9,0 9,0 9,0

Siemens Basic cable


6FX8002-2AD00 6FX8002-2CA11 6FX8002-2CA15 MAT9070001 MAT9070002 MAT9070003 (3x(2x0,14)C+(4x0,14)+(2x0,5))C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5 9,5 10,5

SIEMENS

Siemens Basic cable


6FX8002-2CA31 MAT9070004 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 11,5

Siemens Basic cable


6FX8002-2CA51 6FX8002-2CA71 MAT9070005 MAT9070006 (3x(2x0,14)C+(4x0,14)+(2x0,5))C (4x(2x0,34)+4x0,5)C 10,5 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.391

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Siemens Basic cable


6FX8002-2CB31 MAT9070007(8) (12x0,25)C 9,0

Siemens Basic cable


6FX8002-2CB51 6FX8002-2CC11 6FX8002-2CD01 MAT9070008 MAT9070009 MAT9070010 (4x(2x0,34)+4x0,5)C (4x(2x0,34)+4x0,5)C (4x(2x0,34)+4x0,5)C 9,5 9,5 9,5

SIEMENS

Siemens Basic cable


6FX8002-2CF01 6FX8002-2CF02 6FX8002-2CG00 6FX8002-2CH00 MAT9070021 MAT9070011 MAT9070012 MAT9070013 (3x(2x0,14)C+(4x0,14)+(2x0,5))C (3x(2x0,14)C+(4x0,14)+(2x0,5))C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+(4x0,14)+(2x0,5))C 10,5 10,5 9,5 10,5

Siemens Basic cable


6FX8002-2CK00 MAT9070014 (3x(2x0,14)C+(2x0,5C))C 10,5

Siemens Basic cable


6FX8002-2CL00 MAT9070015 (3x(2x0,14)C+(2x0,5C))C 10,5

Siemens Basic cable


6FX8002-2EQ00 6FX8002-2EQ10 MAT9070016 MAT9070017 (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 11,5 11,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. (8) ohne DESINA G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.392

(for up to 10 cuts of the same type)

Measuring TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Yellow green (similar to RAL 6018)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Siemens Basic cable*


6FX8002-2AH00 MAT9070018 (4x(2x0,34)+4x0,5)C 9,5

Siemens Extension cable


SIEMENS
6FX8002-2AD04 6FX8002-2CB54 6FX8002-2CA54 6FX8002-2CA34 MAT9071001 MAT9071002 MAT9071003 MAT9071004 (3x(2x0,14)C+(4x0,14)+(2x0,5))C (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+(4x0,14)+(2x0,5))C (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C 10,5 9,5 10,5 11,5

Siemens Extension cable


6FX8002-2CB34 MAT9071007(8) (12x0,25)C 9,0

Siemens Extension cable


6FX8002-2CC14 6FX8002-2CF04 6FX8002-2EQ14 6FX8002-2AH04 MAT9071009 MAT9071011 MAT9071017 MAT9071018 (4x(2x0,34)+4x0,5)C (3x(2x0,14)C+(4x0,14)+(2x0,5))C (3x(2x0,14)C+2x0,5+4x0,14+4x0,23)C (4x(2x0,34)+4x0,5)C 9,5 10,5 11,5 9,5

STBER

Stber iMDS5000 Basic cable


Resolver MAT9421005 (3x(2x0,25))C 8,5

Stber iMDS5000 Basic cable


Encoder MAT9421004 (4x(2x0,25)+(2x0,5))C 9,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. (8) ohne DESINA G = with green-yellow earth core x = without earth core

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.393

Measuring TPE

Chainflex-TPE Measuring system cable


G G G G Class 6.4.4 Oil-resistant Shielded Temperature range (moved): -35 C to + 100C G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Stber iSDS4000 Basic cable


STBER
Resolver MAT9421003 (4x(2x0,25)+(2x0,5))C 9,5

Stber iSDS4000 Basic cable


Encoder ED/EK MAT9421001 (4x(2x0,34)+(4x0,5))C 10,5

Stber iSDS4000 Basic cable


Encoder ES MAT9421002 ((6x0,5)+5x(2x0,25))C 12,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.394

(for up to 10 cuts of the same type)

Measuring TPE

G Minimum bending radius for use in Energy Chains: 10 x cable diameter G Colour: Yellow green (similar to RAL 6018)

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.395

Bus TPE

Chainflex-TPE Bus cable


G G G G G Class 6.4.4 Oil-resistant Shielded Hydrolysis-resistant and microbe-resistant Flame-retardant G Nominal voltage: 30 V G Total shield: Total shield: extremely readily bending/solid copper shield. Coverage approx. 70% linear, approx. 90% optical

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

BECKHOFF

Beckhoff Basic cable


ZK1090-9191-xxxx MAT9385001 (2x(2x0,25))C 7,0

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.396

(for up to 10 cuts of the same type)

Bus TPE

G Temperature range (moved): -35 C to + 70C G Minimum bending radius for use in Energy Chains: 12,5 x cable diameter G Colour: Red lilac (similar to RAL 4001)

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.397

Control PVC

Chainflex-PVC Control cable


G Class 4.2.1 G Flame-retardant G Temperature range (moved): -5 C to + 70C G Nominal voltage: 300/500 V G Minimum bending radius for use in Energy Chains: 7,5 x d < 10 travel; 10 x d > 10 m travel

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

NUM

NUM Basic cable*


AGOFRU012Mxxx MAT9289005 4G 1,0 7,5

NUM Extension cable


AGOFRU012Mxxx MAT9289015 4G 1,0 7,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.398

(for up to 10 cuts of the same type)

Control PVC

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.399

Control PVC

Chainflex-PVC Control cable


G G G G Class 5.3.2 Oil-resistant Flame-retardant Temperature range (moved): -5 C to + 70C G Nominal voltage: 300/500 V G Minimum bending radius for use in Energy Chains: 6,8-7,5 x cable diameter G Colour: Moss green (similar to RAL 6005)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Lenze Basic cable*


EWLLxxxGMS EYL002AxxxxL01A00 EYL002AxxxxL02A00 MAT9130031 MAT9130040 MAT9130041 3 G 1,0 5 G 1,0 5 G 1,0 7,0 8,5 8,5

LENZE

Lenze Extension cable*


EYL002VxxxxA00J01 EYL002VxxxxA00J02 MAT9130042 MAT9130043 5 G 1,0 5 G 1,0 8,5 8,5

Lenze Linking cable


EWLLxxxZM EYL002VxxxxL01J01 EYL002VxxxxL02J02 MAT9130032 MAT9130044 MAT9130045 3 G 1,0 5 G 1,0 5 G 1,0 7,0 8,5 8,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.400

(for up to 10 cuts of the same type)

Control PVC

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.401

Control TPE

Chainflex-TPE Control cable


G G G G Class 7.4.4 oil-resistant and bio-oil-resistant Hydrolysis-resistant and microbe-resistant Temperature range (moved): -35 C to + 100C G Nominal voltage: 300/500 V G Minimum bending radius for use in Energy Chains: 5 x cable diameter G Colour: Steel blue (similar to RAL 5011)

Manufacturer Part No.

igus Part No.

Number of cores and conductor nominal cross section [mm ]


2

mm

Lenze Basic cable*


EWLLxxxGMS EYL002AxxxxL01A00 EYL002AxxxxL02A00 MAT9120031 MAT9120040 MAT9120041 3 G 1,0 5 G 1,0 5 G 1,0 6,0 7,0 7,0

LENZE

Lenze Extension cable*


EYL002VxxxxA00J01 EYL002VxxxxA00J02 MAT9120042 MAT9120043 5 G 1,0 5 G 1,0 7,0 7,0

Lenze Linking cable


EWLLxxxZM EYL002VxxxxL01J01 EYL002VxxxxL02J02 MAT9120032 MAT9120044 MAT9120045 3 G 1,0 5 G 1,0 5 G 1,0 6,0 7,0 7,0

NUM Basic cable*


NUM
AGOFRU012Mxxx MAT9289007 4G 1,0 6,5

NUM Extension cable


AGOFRU012Mxxx MAT9289017 4G 1,0 7,5

All cables available in the lengths you require.


Note: The mentioned external diameters are maximum values and may tend toward lower tolerance limits. Image exemplary. * igus gladly pre-harnesses the cable end according to your technical guidelines. G = with green-yellow earth core x = without earth core

950 types from stock no cutting costs ...


4.402

(for up to 10 cuts of the same type)

Control TPE

... no minimum order quantity ...


igus GmbH | Tel. +49-2203-9649-0 | chainflex@igus.eu
4.403

esigning

Chainflex
Data and Schedules
Calculation of the copper surcharge Load-Carrying Capacity of Cables Electrotechnical data Chemical resistance

Page

Technical Data and Schedules/user information/contact


Chainflex cable's classification according to the criteria requirements, oil-resistance and travel distance 4.14-4.15

DIN 47100 colour code/Copper wire dimensions according to Anglo-American AWG numbers

4.406 4.406 4.407 4.408 4.414

Informations
The General Conditions User information, Disclaimer, KTG, Product illustrations Technical notes Approbation and Approvals Configure and order cables online, igus & eplan Chainflex according to Industries

4.416 4.416 4.416 4.417 4.418 4.420

Contact igus
Fax Customer-specific cables for Energy Chain Systems Definition of the icons used in the catalogue 4.419 4.424

4.405

Data and Schedules

Special Cables Information Colour Code + Copper Price DIN 47100 colour code (however, deviating from DIN: without colour repetition after 44th core)*
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 white brown green yellow gray pink blue red black violet gray-pink red-blue white-green brown-green white-yellow yellow-brown 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 white-gray gray-brown white-pink pink-brown white-blue brown-blue white-red brown-red white-black brown-black gray-green yellow-gray pink-green yellow-pink green-blue yellow-blue 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 green-red yellow-red green-black yellow-black gray-blue pink-blue gray-red pink-red gray-black pink-black blue-black red-black white-brown-black yellow-green-black gray-pink-black red-blue-black 49 50 51 52 53 54 55 56 57 58 59 60 61 white-green-black brown-green-black white-yellow-black yellow-brown-black white-gray-black gray-brown-black white-pink-black pink-brown-black white-blue-black brown-blue-black white-red-black brown-red-black black-white

Chainflex

* Exception: 4-core cables are braided in the colour sequence white, green, brown, yellow.

The first colour indicates the basic colour of the core insulation, and the second colour indicates the colour of the printedon ring. In the case of three colours, the second and colours are printed on the basic colour. Calculation of the copper surcharge The copper surcharge is the calculation of the difference between the calculated price (copper basis) and the fluctuating, actual price of the copper share in a cable. In calculatory terms, the list price of each Chainflex cable is based on a copper

The copper index specifies the weight of the copper share in a cable in kg/km. The product from the copper index (kg/km) and the price difference per kg of copper according to the DEL quotation then provides the copper surcharge in per km of cable. Here, the following example: Cable: Copper index: DEL quotation: Copper basis: Chainflex CF9.15.18 260 kg/km 189,/100 kg Cu 150,/100 kg Cu = Copper surcharge [/km]

Tel. +49-2203-96 49-0 Fax +49-2203-96 49-222

price to the amount of 150,-/100 kg of copper. In the end, however, this copper share is calculated on the basis of the current daily price according to the DEL (German abbr. = German electrolyte copper for conducting purposes) quotation. Copper index [kg/km] x 260 x 189 150 100 Copper surcharge = 101,40 /km

DEL quotation [ /100 kg] Copper basis [ /100 kg] 100

= Copper surcharge [/km]

For this example, the copper surcharge amounts to 101.40/km of cable. Any discounts that are granted only apply to the cable prices but not to the copper surcharge. The copper surcharge is shown separately on our invoices. New: You now have the possibility of calculating the individual extra charge for copper for your cable on-line www.igus.eu/en/cfcu

51147 Kln, Germany

Copper wire dimensions according to Anglo-American AWG numbers


AWG No.
500 350 250 4/0 3/0 2/0 1/0 1 2 4 6 8 10 12 14 16

igus GmbH

Diameter mm
17,96 15,03 12,70 11,88 10,40 9,27 8,25 7,35 6,54 5,19 4,12 3,26 2,59 2,05 1,63 1,29

Cross section mm
2

AWG No.
18 20 22 24 26 28 30 32 34 36 38 40 42 44

Diameter mm
1,024 0,813 0,643 0,511 0,405 0,320 0,255 0,203 0,160 0,127 0,102 0,079 0,064 0,051

Cross section mm2


0,823 0,519 0,324 0,205 0,128 0,0804 0,0507 0,0324 0,0200 0,0127 0,00811 0,00487 0,00317 0,00203

253,00 177,00 127,00 107,20 85,00 67,50 53,50 42,40 33,60 21,20 13,30 8,37 5,26 3,31 2,08 1,31

www.igus.eu

4.406

info@igus.de

Special Cables Information Load-Carrying Capacity of Cables


The values from the tables on the side of this page have been taken from the standard DIN VDE 0298, Part 4. These values have been simplified and only apply and comply with the regulations that apply to each individual case of application (e.g. measures for protection in case of indirect contact in accordance with DIN VDE 0100 Part 410, overcurrent protective devices in accordance with DIN VDE 0100 Part 430 or voltage drop in accordance with DIN VDE 0100 Part 520). It is not possible to provide all the regulations or overviews In this catalog. Due to the harmonization that has been carried out, it is possible that different load-carrying values may be permissible for the same cable in some cases. For the selection of the relevant cross sections, the load capacity in undisturbed operation is the determining factor, i.e. the use with permissible operating temperature or permissible maximum temperature on the conductor. The load-bearing capacity according to Table 1 on this page applies to operating-current-carrying conductors. Normally, these are 2 loaded conductors in the case of 2-core and 3-core cables, as well as 3 loaded conductors in the case of 4-core and 5-core cables. Please take this into account when planning for the use of multi-core cables in electrical installation conduits or Energy Chains. This information is based on an ambient temperature of 30C and a non-loaded cable. Please apply the conversion factors according to Table 2 in case the air temperature is increased due to the heat loss of the cables (please take thermal radiation into account as well, e.g. effects of exposure to the sun). The possible cable installation types in Energy Chains result in such a broad range of loading profiles that no generalized conversion factors can be mentioned for this large accumulation of cables. The installation type and the conversion factors must be looked up in Table 3 according to each individual application. Table 2: Conversion factors in case of varying ambient temperatures
Ambient temperature C 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Conversion factor PVC TPE insulation insulation 1,22 1,17 1,12 1,06 1,00 0,94 0,87 0,79 0,71 0,61 0,50 1,15 1,12 1,08 1,04 1,00 0,96 0,91 0,87 0,82 0,76 0,71 0,65 0,58 0,50 0,41 0,29 0,14 Nominal cross section Load-carrying capacity in amperes Nominal cross of PVC TPE copper cable in insulation insulation mm2 0,14 2,5 2,5 0,25 4 5 0,34 5 7 0,50 8 10 0,75 12 14 1 15 17 1,50 18 21 2,50 26 30 4 34 41 6 44 53 10 61 74 16 82 99 25 108 131 35 135 162 50 168 202 70 207 250 95 250 301 120 292 352 150 404 185 461 Number of cores Installation 2 or 3

Data and Schedules

Table 1: Cables for fixed installation in energy-conducting chains and tubes


Insulation material Chainflex type PVC TPE

CF5, CF6, CF2, CF130.UL, CF140.UL, CF211(D) CF77.UL.D, CF78.UL, CF9, CF10, CF9.UL, CF10.UL, CF98, CF99, CF240, CF211, CF112, CF113, CF11, CF12, CF211(M), CF113.D, CF111.D, CF11.D, CF210.UL, CF21.UL, CF270.UL.D, CF27.D, CF30, CF31, CF34.UL.D, CF35.UL, CF37.D, CF38, CF300.UL.D, CFPE, CF310.UL, CF330.D, CF340, CFBRAID, CFROBOT, CFROBOT 6,7,9

Table 3: Conversion factors for multi-core cables with cable cross sections up to 10 mm2
Loaded cores 5 7 10 14 19 24 40 61 Conversion factor 0,75 0,65 0,55 0,50 0,45 0,40 0,35 0,30

4.407

Tel. +49-2203-96 49-0 Fax +49-2203-96 49-222

Chainflex

approximately. For each user, it is advisable to obtain

Data and Schedules

Special Cables Information Electrotechnical data

The following tables provide measured values on the electrotechnical data of the cables available at the time of the survey. The values are understood as being approximate values. For precise information on the actually available cables, individual measurements are absolutely required.

The specification of the characteristic wave impedance at high frequencies in is an important quantity for a reflection-free matching of cables, e.g. in bus systems. With respect to the combination of various cables types and lengths, an adaptation must be provided via a matching resistor.

Cable type CF130.UL, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. Cable type CF140.UL, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. Cable type CF5, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. Cable type CF6, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. Cable type CF2, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

0,14 276

0,25 158

0,34 114 120 635 80

0,5 78 105 65 650 90 150 150

0,75 52 110 65 640 90 190 0,75 52 140 75 630 80 360 0,75 52 115 105 670 80 190 225 0,75 52 150 120 680 75 400 275 0,75 52 110 130 740 85 320 300

1 39 125 90 620 80 190 1 39 140 90 630 75 370 1 39 135 105 670 80 210 230 1 39 165 120 640 70 420 290 1 39 110 105 730 85 320 260

1,5 26.6 125 610 80 205 205 1,5 26.6 165 90 620 70 430 1,5 26.6 185 135 640 65 460 330 1,5 26.6 185 135 640 65 460 330 1,5 26.6 135 135 670 75 370 330

2,5 16 140 610 70 210 2,5 16 190 620 60 510 2,5 16 125 670 150

4 9.9

6 6.6 140 565 65 230

10 3.8

16

0,14 276

0,25 158

0,34 114 125 650 80 310

0,5 78 125 650 80 310 0,5 78 95 90 720 85 165 207 0,5 78 135 110 690 80 340 275 0,5 78

4 9.9

6 6.6

10 3.8

16

0,14 276

0,25 158

0,34 114 120 760 85 325

4 9.9

6 6.6

10 3.8

16

0,14 276

0,25 158 130 725 80 340

0,34 114 125 700 80 340 0,34 114

2,5 16

4 9.9

6 6.6

10 3.8

16

0,14 276 110 100 690 90 280

0,25 158 130 120 630 80 305 270

2,5 16

4 9.9

6 6.6

10 3.8

16

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 230

* The following values are approximate values, calculated from measurements of cables with different numbers of cores. The loop resistance can be maximally 5% over the specified value for cables that are very lavishly stranded in bundles (from 12 cores).

4.408

Special Cables Information Electrotechnical data

Data and Schedules

Cable type CF9, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. Cable type CF10, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx.

0,14 276

0,25 158 70 80 670 100 115 200

0,34 114 75 650 100 135 0,34 114

0,5 78 85 90 650 90 135 185 0,5 78 105 95 620 85 245 205

0,75 52 85 100 620 85 145 255 0,75 52 110 105 590 80 260 225 0,75 52 85 100 620 85 145 255 0,75 52 110 105 590 80 260 225 0,75

1 39 95 105 590 80 145 235 1 39 120 115 580 75 290 255 1 39 95 105 590 80 145 235 1 39 120 115 580 75 290 255 1

1,5 26.6 100 120 560 75 170 215 1,5 26.6 125 120 575 75 290 265 1,5 26.6 100 120 560 75 170 215 1,5 26.6 125 120 575 75 290 265 1,5

2,5 16 125 130 560 70 190 225 2,5 16 150 130 555 65 345 275 2,5 16 125 130 560 70 190 225 2,5 16 150 130 555 65 345 275 2,5

4 9.9 120 600 70 150 4 9.9

6 6.6 100 520 70 185 6 6.6

10 3.8

16 2.6 130 530 65 200

0,14 276 80 680 100

0,25 158 90 95 670 90 215 200 0,25 158 70 80 670 100 115 200

10 3.8

16

Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 180 Cable type CF9.UL, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. Cable type CF10.UL, Nominal cross section * Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance up to 7 cores in nF/km approx. Loop capacitance from 12 cores in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance: 2 cores versus all others up to 7 cores in nF/km approx. Capacitance: 2 cores versus all others up to 12 cores in nF/km approx. 180 Cable type CF98, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. 276 62 600 115 100 0,14 80 680 100 276 0,14 276 0,14

0,34 114 75 650 100 135 0,34 114

0,5 78 85 90 650 90 135 185 0,5 78 105 95 620 85 245 205

4 9.9 120 600 70 150 4 9.9

6 6.6 100 520 70 185 6 6.6

10 3.8

16 2.6 130 530 65 200

0,25 158 90 95 670 90 215 200 0,25 158 75 565 115 120

10 3.8

16

0,34

0,5

10

16

* The following values are approximate values, calculated from measurements of cables with different numbers of cores. The loop resistance can be maximally 5% over the specified value for cables that are very lavishly stranded in bundles (from 12 cores).

4.409

Data and Schedules

Special Cables Information Electrotechnical data

Cable type CF240, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Operating capacity at 1 kHz in nF/km approx. Characteristic wave impedance at 1 kHz in Cable type CF211, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Operating capacity at 10 MHz in nF/km approx. Characteristic wave impedance at 1 kHz in Characteristic wave impedance at 10 MHz in approx. Cable type CF111, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Operating capacity at 10 MHz in nF/km approx. Characteristic wave impedance at 1 kHz in Characteristic wave impedance at 10 MHz in approx. Cable type CF11, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Operating capacity at 10 MHz in nF/km approx. Characteristic wave impedance at 1 kHz in Characteristic wave impedance at 10 MHz in approx. Cable type CF12, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Operating capacity at 10 MHz in nF/km approx. Characteristic wave impedance at 1 kHz in Characteristic wave impedance at 10 MHz in approx. Cable type CF113.D, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Operating capacity at 1 kHz in nF/km approx. Characteristic wave impedance at 1 kHz in Cable type CF111.D, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Operating capacity at 1 kHz in nF/km approx. (pair shielded) Operating capacity at 1 kHz in nF/km approx. (pair unshielded) Characteristic wave impedance at 1 kHz in (pair shielded) Characteristic wave impedance at 1 kHz in (pair unshielded) Cable type CF11.D, Nominal cross section Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Operating capacity at 1 kHz in nF/km approx. Characteristic wave impedance at 1 kHz in

0,14 276 100 95 0,14

0,25 158 110 85 300 0,25 158 157 75 60

0,34 114 120 80 305 0,34 114 145 70 50 0,34 114 145 70 50 0,34 114 115 85 60 0,34 114

0,5

0,75

1,5

2,5

10

16

Capacitance: 2 cores versus all others cores and shield in nF/km approx. 240

0,5 78 125 80 60 0,5 78 125 80 60 0,5 78 140 75 50 0,5 78 165 70 45

0,75

1,5

2,5

10

16

0,14

0,25 158 157 75 60

0,75

1,5

2,5

10

16

0,14 276 100 100 70 0,14 276

0,25 158 110 85 65 0,25 158 150 70 45

0,75 52 145 70 50 0,75 52

1 39 150 65 45 1 39 200 50 35

1,5 26.6 150 60 45 1,5 26.6

2,5 16 180 60 40 2,5 16

4 9.9

6 6.6

10 3.8

16

4 9.9

6 6.6

10 3.8

16

0,14 276 55 - 80 110 0,14 276 80 55 105 115 0,14 276 55 - 80 110

0,25 158 65 105 0,25

0,34 114 55 125 0,34 114 55 115

0,5 78 50 - 110 75 - 155 0,5 78 65 80 130 90 0,5 78 50 - 110 75 - 155

0,75 52

1 39

1,5 26.6

2,5 16

4 9.9

6 6.6

10 3.8

16

0,75 52

1 39

1,5 26.6

2,5 16

4 9.9

6 6.6

10 3.8

16

0,25 158 65 105

0,34 114 55 125

0,75 52

1 39

1,5 26.6

2,5 16

4 9.9

6 6.6

10 3.8

16

4.410

Special Cables Information Electrotechnical data

Data and Schedules

Cable type CF21.UL, Energy conductor Single impedance in /km approx. Operating capacity in nF/km approx. Operating inductane in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. Cable type CF21.UL, Signal pair Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. Cable type CF27, Energy conductor Single impedance in /km approx. Operating capacity in nF/km approx. Operating inductane in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. Cable type CF27, Signal pair Conductor loop consisting of two adjacent cores, aprox. Loop resistance in /km approx. Loop capacitance in nF/km approx. Loop inductance in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx.

0,75 26 150 365 95 130 0,34 114 80 580 90 140 0,75 26 170 360 95 145 0,5 78 92 650 90 170

1 19.5 165 365 95 140 0,75 52 100 600 80 175 1 19.5 180 380 90 150 0,75 52 100 600 80 175

1,5 13.3 190 350 80 170 1,5 26.6 130 600 75 240 1,5 13.3 220 355 80 185 1,5 26.6 130 600 75 240

2,5 7.98 200 340 80 170

4 4.95 225 340 70 200

6 3.3 245 340 70 210

10 1.91 320 330 60 270

16 1.21

25 0.78

35 0.554

50 0.386

2,5 7.98 220 355 80 185

4 4.95 250 325 70 205

6 3.3 260 310 70 215

10 1.91 285 310 65 240

16 1.21

25 0.78 350 310 65 295

35 0.554 595 310 45 495

50 0.386

4.411

Data and Schedules

Special Cables Information Electrotechnical data

Cable type CF30, Nominal cross section Single impedance in /km approx. Operating capacity in nF/km approx. Operating inductane in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. Cable type CF31, Nominal cross section Single impedance in /km approx. Operating capacity in nF/km approx. Operating inductane in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. Cable type CF34.UL.D, Nominal cross section Single impedance in /km approx. Operating capacity in nF/km approx. Operating inductane in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. Cable type CF35.UL, Nominal cross section Single impedance in /km approx. Operating capacity in nF/km approx. Operating inductane in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx.

1,5 13.3 145 330 95 110 1,5 13.3 190 330 85 170 1,5 13.3 120 340 100 90 1,5 13.3

2,5 7.98 155 330 95 115 2,5 7.98 200 330 80 180 2,5 7.98

4 4.95 170 320 90 130 4 4.95 215 320 75 190 4 4.95 145 320 95 110

6 3.3 170 320 90 130 6 3.3 235 320 70 210 6 3.3 150 320 95 110 6 3.3 190 320 85 170

10 1.91 195 310 80 150 10 1.91 270 310 70 240 10 1.91

16 1.21 215 300 70 160 16 1.21 295 260 60 280 16 1.21 200 310 90 140

25 0.78 220 295 70 170 25 0.78 300 260 60 250 25 0.78 175 310 90 130 25 0.78

35 0.554 270 290 65 200 35 0.554 305 260 60 285 35 0.554

50 0.386

70 0.272

50 0.386 370 260 55 330 50 0.386

70 0.272 500 260 50 440 70 0.272

2,5 7.98 160 330 100 140

4 4.95 180 320 85 155

10 1.91 215 310 75 190

16 1.21 260 290 70 220

35 0.554

50 0.386

70 0.272

4.412

Special Cables Information Electrotechnical data

Data and Schedules

Cable type CF37.D, Nominal cross section Single impedance in /km approx. Operating capacity in nF/km approx. Operating inductane in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. Cable type CF38, Nominal cross section Single impedance in /km approx. Operating capacity in nF/km approx. Operating inductane in H/km approx. Characteristic wave impedance at 1 kHz in Capacitance of one core versus all other cores in nF/km approx. Cable type CF300.UL.D, Nominal cross section Resistance in /km approx. Cable type CF310.UL, Nominal cross section Resistance in /km approx. Cable type CF330.D, Nominal cross section Resistance in /km approx. Cable type CF340, Nominal cross section Resistance in /km approx. 1,5 13.3 1,5 13.3 1,5 13.3 1,5 13.3 2,5 7.98 2,5 7.98 2,5 7.98 2,5 7.98

1,5 13.3 120 340 100 90 1,5 13.3

2,5 7.98

4 4.95 145 320 95 110

6 3.3 150 320 95 110 6 3.3 190 320 85 170 16 16 16 16 25 25 25 25

10 1.91

16 1.21 200 310 90 140

25 0.78 175 310 90 130 25 0.78

35 0.554

50 0.386

70 0.272

2,5 7.98 160 330 100 140

4 4.95 180 320 85 155 10 10 10 10

10 1.91 215 310 75 190 35 35 35 35

16 1.21 260 290 70 220 50 50 50 50

35 0.554

50 0.386

70 0.272

4 4.95 4 4.95 4 4.95 4 4.95

6 3.3 6 3.3 6 3.3 6 3.3

70 70 70 70

95 95 95 95

120 120 120 120

150 150 150 150

185 185 185 185

240 240 240 240

1.910 1.210 0.780 0.554 0.386 1.910 1.210 0.780 0.554 0.386 1.910 1.210 0.780 0.554 0.386 1.910 1.210 0.780 0.554 0.386

0.272 0.206 0.161 0.129 0.106 0,0801 0.272 0.206 0.161 0.129 0.106 0,0801 0.272 0.206 0.161 0.129 0.106 0,0801 0.272 0.206 0.161 0.129 0.106 0,0801

4.413

Data and Schedules

Special Cables Information Chemical resistance

Group

Chainflex cable

Jacket material

1
1 1

2
2 2

Page

Control cable Control cable CF130.UL Control cable CF140.UL Control cable CF5 Control cable CF6 Control cable CF77.UL.D Control cable CF78.UL Control cable CF170.D Control cable CF180 Control cable CF2 Control cable CF9 Control cable CF10 Control cable CF9.UL Control cable CF10.UL Control cable CF98 Control cable CF99 Data cable Data cable CF240 Data cable CF211 Data cable CF112 Data cable CF113 Data cable CF11 Data cable CF12 Bus cable Bus cable CFBUS Bus cable CF11.LC Bus cable CF11.LC.D Bus cable CF14 Measuring system cable Measuring system cable CF211 Measuring system cable CF113.D Measuring system cable CF111.D Measuring system cable CF11.D Koax cable Koax cable CFKoax1 Fibre optic cable Fibre optic cable CFLK Fibre optic cable CFLG.2H Fibre optic cable CFLG.LB Fibre optic cable CFLG.G Servo cable Servo cable CF210.UL Servo cable CF21.UL Servo cable CF27.D Servo cable CF270.UL.D Power cable Power cable CF30 Power cable CF31 Power cable CF34.UL.D Power cable CF35.UL Power cable CF37.D Power cable CF38 Power cable CF300.UL.D Power cable CFPE Power cable CF310.UL Power cable CF330.D Power cable CF340 Power cable CF BRAID

PVC PVC PVC PVC PUR PUR PUR PUR PUR TPE TPE TPE TPE TPE TPE PVC PVC PUR PUR TPE TPE TPE TPE TPE TPE PVC PUR TPE TPE TPE PUR PUR TPE TPE PVC PVC PUR PUR PVC PVC TPE TPE TPE TPE TPE TPE TPE TPE TPE TPE

3 3 3 3 3 4 4 4 4 4 4 2 2 3 3 4 4 4 4 4 4 2 3 4 4 4 3 3 4 4 2 2 3 3 2 2 4 4 4 4 4 4 4 4 4 4

4.52 4.56 4.60 4.64 4.68 4.70 4.72 4.74 4.76 4.80 4.84 4.88 4.92 4.96 4.98 4.102 4.104 4.106 4.108 4.110 4.112 4.122 4.126 4.128 4.130 4.132 4.136 4.142 4.146 4.152 4.158 4.160 4.162 4.164 4.168 4.170 4.174 4.178 4.184 4.186 4.188 4.190 4.192 4.194 4.196 4.198 4.200 4.202 4.204 4.208

4.414

Special Cables Information Chemical resistance

Data and Schedules

Cable type

1
+ + + O O + + O O O O O O +

2
+ + + + + + + O O O O O O +

3
+ + + O O + + O O O O O +

4
+ + + + + + + + + O O + O + + +

Inorganic chemicals Aqueous solutions, neutral Water Common salt (10%) Glauber's salt (10%) Aqueous solutions, alkaline Soda (10%) Aqueous solutions, acid Sodium bisulfate (10%) Aqueous solutions, oxidizing Hydrogen peroxide (10%) Potassium permanganate (2%) Inorganic acids Hydrochloric acid, concentrated Hydrochloric acid (10%) Sulfuric acid, concentrated Sulfuric acid (10%) Nitric acid, concentrated Nitric acid (10%) Inorganic caustic solutions Soda lye, concentrated Soda lye (10%) Potassium lye, concentrated Potassium lye (10%) Ammonia, concentrated Ammonia (10%) Organic chemicals / organic acids Acetic acid, concentrated (glacial acetic acid) Acetic acid (10% in H20) Tartaric acid (10% in H20) Citric acid (10% in H20) Ketones Acetones Methyl ethyl ketone (MEK) Alcohols Ethyl alcohol (spirit) Isopropyl alcohol Diethylene glycol Aromatic compounds Toluol Xylol Fuels Gasoline Diesel fuel Synthetic oils / lubricating oil ASTM oil #2 Hydraulic oil Mineral oil base Glycol base Synthetic ester base Vegetable oils Rapeseed oil Olive oil Soya bean oil Cold cleaning agent Cold cleaning agent

O O O O

+ + + O O O O O

O + + O O + O O + +

O + + + O O + + + + +

O O O O O

+ O O O + + + O

+ + + + + + + +

+ + + + + + + O

+ no or minimum negative influence O medium reciprocal effect, short-term exposure permissible unstable, material partly destroyed

All information applies to room temperature

4.415

Data and Schedules

Information

The General Conditions


The General Conditions of Sale of igus shall apply. Excessive and short deliveries of 10 % for cables conform with contractual agreements. Deliveries can be made in partlengths. Statutory VAT must be added to the prices. The General Conditions of Sale and Delivery of igus GmbH, Cologne, can be found online under www.igus.de. The prices quoted in the catalogue or other media are subject to alteration. igus can modify the prices at any time at their own discretion.

Chainflex

User information
Since our products are constantly being developed further in the interest of our customers, we reserve the right to make technical alterations at any time. With the issue of this catalog, all previous publications lose their validity. Subject to printing errors.

Disclaimer
The terms "igus", ReadyCable", "ReadyChain", "Chainflex", "E-Chain Systems", "Energy Chain", "Energy Chain Systems", "E-Ketten", "E-KettenSysteme", "Flizz", "iglidur", "DryLin" are legally protected trademarks in the Federal Republic of Germany and in case also in foreign countries. Fax +49-2203-96 49-222 Tel. +49-2203-96 49-0

KTG
If cable drums are to be used, please visit KTG directly online. www.kabeltrommel.de

Product illustrations
The products illustrated are photos showing examples for whole series, i.e. the original cable can deviate from the cable shown.

Technical notes
51147 Kln, Germany The USB, FireWire and GigE-cables shown on these pages were developed for the ambitious industrial usage in E-Chains. High proofness to oil and lubricants is as secured as protection against electromagnetical interferences. This high mechanical service life was reached with the usage of high quality materials which even care for the electrical safeness.In single cases communication errors can occur, if very different hardware and software is combined. We recommend tests with all components and the cables before starting serial production, to get the proove for a perfect running system. Of course we support you with the details of these electrical tests. Just give us a call! The specifications in the catalogue referring to temperature range, bending radius and travel must be seen as limiting value specifications. If two limiting value specifications are combined, this can lead to a reduction of the cable's service life. The term "oilresistant" refers to a few selected oil types which have been tested accordingly. This does not mean, however, that the products are automatically resistant to all the oils on the market. Length printing: Respective printing of the metre length is already on many cables. These are not calibrated measurements, they are only intended as an orientation aid. Just give us a call!

igus GmbH www.igus.eu

4.416

info@igus.de

Special Cables Information Approbation and Approvals

Data and Schedules

igus Chainflex cables for DESINA


DESINA: DEcentral and Standardised INstAllation technique is a recommendation of the Verein Deutscher Werkzeugmaschinenfabriken (VDW = Association of German machine tool industry) for the purpose of standardising components, interfaces and connecting systems. DESINA describes an extensive whole concept for standardisation and decentralisation of the fluid technical and electrical installation of machines and plants.
For further information: www.desina.de

Underwriters Laboratories Inc.


For further information: www.ul-europe.com

Underwriters Laboratories Inc.


For further information: www.ul-europe.com

Canadian Standards Association


For further information: www.csa.ca

Communaut Europenne

www.igus.eu

igus GmbH

4.417

info@igus.de

51147 Kln, Germany

Commission lectrotechnique Internationale

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Chainflex

Configure and order cables online


igus provides electronic support
Rectangular connectors, Sub D connectors, round connectors you can now select cables yourself from your workplace or home PC. Experienced users will only need about one and a half minutes to assemble the cable they need via the Internet. The comwponents selected and all available ex-stock can then be placed in a virtual shopping basket and delivered by igus without delay.

Filter the optimum cable out and order online


Using the QuickCable product finder, available online under www.igus.eu/quickcable, users can first search for the optimum technical solution and then make an online inquiry or place an order. Cable selection is via a choice of parameters: electrical, dynamic, mechanical and chemical parameters and environmental questions. Direct cable selection is also possible, of course.

Individual pin assignment


Once the cable type has been found, the new QuickPin configurator is the next step. Under www.igus.eu/quickpin, igus offers all its connector types in a convenient menu, including reason test. The pin or wire contact assignment is flexible, depending on the user's requirements. The contacts can be assigned logically per mouse click, the pole images are then represented by symbols. This means that instead of a list in a table, the pin assignment can be viewed as an image on one page.

Calculate service life online


Calculate service life online depending on the parameters travel, bending radius and speed. The program checks the logical plausibility of the parameters entered. The result is given in the number of double strokes to be expected. If other cable types could achieve better results on the basis of the parameters entered, this will be noted.

igus &

Chainflex cable library for eplan

G The article data of all Chainflex G G G

cables are now downloadable in eplan standard! www.igus.eu/eplan-download Completely created cable type file, including information on colour codes, crosssections, shields, etc. Cable article file in eplan format for piece lists or order lists Fully compatible with eplan 5/eplan 8

i-net customer information system available at www.igus.eu


Track your order in real time with igus i-net. Simply apply for your password, log in and you can then track your job status via webcam. You can also use the igus i-net carrier tracking system to track your ordered merchandise from the igus shipping process right up to your front door. G Webcams G More precise order data including an overview of target-actual deadlines G Selection whether you prefer order confirmation or invoice by letter, fax or e-mail

4.418

igus Chainflex
Customer-specific cables for Energy Chain Systems
Date: Sender: Phone: +49-2203-96 49-0 Fax: +49-2203-96 49-222 Recipient: igus GmbH Technical Marketing Spicher Str. 1a Fax: Germany Phone: 51147 Kln

Fax

Special applications in the sector of flexible energy supply systems depend on special cables that function for a long time. As a manufacturer of Energy Chains and the corresponding cables, we will plan your specific requirement case on a customized basis already starting from a cable length of 500 meters. Planning and calculation security will save you time and money. The is why our offers get to the point quickly. Please help us by filling out this questionnaire as completely as possible. With several brief items of information from the selection list, we will be glad to make you an offer. But we will also be pleased to help in person or by telephone with the clarification of technical details.

Electrical properties of the requested cable


Voltage class < 30 V 300/300 V 300/500 V 450/750 V 600/1000 V or operating voltage Cable type Data cable Twisted-pair Fibre-optic Bus specification Control cable Power cable Servo cable or other

I I I I I ______________________________

Mechanical properties of the requested cable


Application case (short description): ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ ______________________________________________________________ Energy Chain series Bending radius Velocity Acceleration Travel distance ______________________________ R ______________________________ V ______________________________ a ______________________________ S ______________________________

Cores Quantity / Cross section I ___________________________ Shielding Total shield Pair shielding Sheath material PVC PVC oil-resistant PUR TPE Pair shielding Hybrid cable or other Additional options Flame-retardant Halogen-free or other Approbation CE CSA DESINA UL or other Other items Max. external

I I

Travel frequency Number of double strokes/ day to be expected ______________________________ Number of manufacturing days to be expected ______________________________ or Environment Temperature (highest/lowest) Chemical influences (oils, etc.) Outdoor/Indoor use or ______________________________

I I I ___________________________

______________________________ ______________________________ OI II

___________________________ CI

______________________________

Numeral printing/colour code N I

Estimated requirement/year ___________________________

4.419

info@igus.de

www.igus.eu

I I I I I ___________________________

51147 Kln, Germany

igus GmbH

I I I I I I I ___________________________

Fax +49-2203-96 49-222

Technical information

Tel. +49-2203-96 49-0

I I I I I I I I ___________________________

Harnessing

4.52

CF130.UL CF140.UL CF5

Chainflex Quick Selection

4.420
Page Packaging Handling Automation Machine Tools/ Processing Machines
4.56 4.60 4.64

DESINAconforming

UL and/or CSA approval

PVC-free/ halogen-free

Cutting and Wel- Timber Processing Low-Temperature ding Systems Machines Applications

Cranes/Harbor Cranes/Materials-Handling Equipment Technology Storage and Systems/Materials- Retrieval Units for HighHandling TechnoBay/ Warehouses/ logy/Outdoor Indoor areas

CF6
4.68 4.70 4.72 4.74 4.76 4.80 4.84 4.88 4.92 4.96 4.98 4.102 4.104 4.106 4.108 4.110

CF77.UL.D CF78.UL CF170.D CF180 CF2 CF9 CF10 CF9.UL CF10.UL CF98 CF99 CF240 CF211 CF112 CF113 CF11

Control Cables Data Cables

Chainflex according to Industries


Bus Cables
CF11.LC.D CF14CAT5 CF11.LC CFBUS

Measuring system Fibre optic cables (FOC) cables/Koax


CFKoax1 CFLG.2H CFLG.LB CF113.D CF111.D CFLG.G CF11.D CF211 CFLK

CF12

Chainflex Quick Selection


Page

4.112

4.122

4.126

4.128

4.130

4.132

4.136

4.142

4.146

4.152

4.158

4.160

4.162

4.164

PVC

4.421

CF210.UL CF21.UL CF270.UL.D

Chainflex Quick Selection

4.422
Page Packaging Handling Automation
4.168 4.170

DESINAconforming

UL and/or CSA approval

PVC-free/ halogen-free

Cutting and Wel- Timber Processing Low-Temperature ding Systems Machines Applications

Cranes/Harbor Cranes/Materials-Handling Equipment Technology Storage and Systems/Materials- Retrieval Units for HighHandling TechnoBay/ Warehouses/ logy/Outdoor Indoor areas Machine Tools/ Processing Machines

Servo Cables

4.174 4.178 4.184 4.186 4.188 4.190 4.192 4.194 4.196 4.198 4.200 4.202 4.204 4.208 4.210 4.212 4.214

CF27.D CF30 CF31 CF34.UL.D CF35.UL CF37.D CF38 CF300.UL.D CFPE CF310.UL CF330.D CF340 CFBRAID CFCRANE CFAIR CFClean AIR

Power Cables Hoses

Chainflex according to Industries


Twistable Cables
CFROBOT6/7 CFROBOT9 CFROBOT8 CFROBOT5 CFROBOT

Chainflex Quick Selection


Page

4.220

4.222

4.228

4.226

4.230

PVC

4.423

Info

Definition of the icons used in the catalogue

Temperature range moved

Temperature range fixed

v max. unsupported/ gliding

Torsion

a max.

Chainflex

Travel distance

UV-resistant

Nominal voltage

Testing voltage

Oil

Offshore

Flame-retardant

Silicon-free

Halogen-free

Lead free

Outer jacket

Outer jacket

Inner jacket

Intermediate jacket

Core stranding

Fax +49-2203-96 49-222

Tel. +49-2203-96 49-0

Core identification

Conductor

Fibre Cables

Core insulation

Overall shield

Center element

Filling

Element shield

Element jacket

Material

51147 Kln, Germany

Dimensions

igus GmbH

Operating pressure

Vacuum

UL

UL/CSA

CSA

CEI

CE

DESINA

Clean room

4.424

info@igus.de

www.igus.eu

www.igus.eu

igus GmbH

Tel. +49-2203-96 49-0 Fax +49-2203-96 49-222

Notes

4.425

info@igus.de

51147 Kln, Germany

Chainflex

También podría gustarte