User Manual
http://www.chromalox.com
Section
Safety ........................................................................................................................................................... Safety Symbols ........................................................................................................................................... Safety Notes and Precautions .................................................................................................................... Static Electricity .......................................................................................................................................... 1. General Description .................................................................................................................................. 1.1 ECR1 Features .................................................................................................................................... 1.2 Ordering Codes and Accessories ....................................................................................................... 1.3 Expandable Input and Output cards ................................................................................................... 1.4 Storage Media CF card ....................................................................................................................... 1.5 Infrared Detector .................................................................................................................................
2. Installation and Wiring .............................................................................................................................. 7 2.1 Unpacking ........................................................................................................................................... 7 2.2 Installation ........................................................................................................................................... 7 2.3 Setup Input, Output & 24VDC Power Supply Cards ......................................................................... 10 2.4 Wiring for the Cards .......................................................................................................................... 11 2.5 RS-232, RS-422, RS-485 wiring ....................................................................................................... 12 2.6 Installation of Compact Flash CF Card ............................................................................................. 13 3. Basic Operation ....................................................................................................................................... 3.1 Page .................................................................................................................................................. 3.2 Mode ................................................................................................................................................. 3.3 History ............................................................................................................................................... 3.4 Event ................................................................................................................................................. 3.5 Status ................................................................................................................................................ 3.6 Exit .................................................................................................................................................... 3.7 Dump ................................................................................................................................................ 3.8 Clear .................................................................................................................................................. 3.9 Operate ............................................................................................................................................. 3.10 Configuration Details ......................................................................................................................... 3.11 Shutdown .......................................................................................................................................... 3.12 Small Icons ........................................................................................................................................ 4. Configuration ........................................................................................................................................... 4.1 Channel ............................................................................................................................................. 4.2 Display .............................................................................................................................................. 4.3 Tools (Timer, Counter & Totalizer) ...................................................................................................... 4.4 Instrument ......................................................................................................................................... 4.5 Clock ................................................................................................................................................. 4.6 System Info ....................................................................................................................................... 4.7 Demo ................................................................................................................................................. 4.8 A Configuration Example .................................................................................................................. 5. PC Software Observer I & II ................................................................................................................. 5.1 Hardware Requirements ................................................................................................................... 5.2 Set-Up ............................................................................................................................................... 5.3 PC Software Manual HELP ............................................................................................................ 5.4 Observer I The basic software for Non-Communication Application ............................................ 5.5 Observer II The extensive software for Communication Application ............................................. 5.6 How to use PC Software ................................................................................................................... 14 14 14 14 15 15 15 16 16 16 16 16 16 17 18 20 21 23 24 24 24 24 26 26 26 26 26 27 28
6. Mathematics ............................................................................................................................................ 30 6.1 Math Expressions and an example ................................................................................................... 30 7. Specifications .......................................................................................................................................... 7.1 General Specifications ...................................................................................................................... 7.2 Communications ............................................................................................................................... 7.3 Data Security..................................................................................................................................... 2006 Chromalox, Inc. 31 31 33 33 -1-
Table of Contents
Page
2 2 2 2 3 3 4 5 6 6
http://www.chromalox.com
This recorder is compliant with the requirements of EN61010-1, UL 61010C-1 & CSA C22.2 No. 1010.1-92. The protection provided by the recorder may be impaired if it is used in a manner inconsistent with its intended purpose, or in an environment that exceeds the specifications of the recorder. Chromalox, Inc.. is not liable for the users failure to comply with these requirements.
Safety Symbols
The following symbols may be seen on the recorder labeling.
Safety Notes and Precautions 1. The protective earth ground terminal should be connected first, before any other connection is made. To avoid dangerous conditions, any interruption to the protective Earth conductor inside or outside the recorder is prohibited. Even in the case of a portable unit, the protective earth terminal must remain connected if the recorder is connected to any hazardous voltage. 2. Keep signal and supply voltage wiring separated from one another. If this is impractical, use shielded cables for signal wiring. Double insulation should be used for signal wiring when the recorder is being used with hazardous voltage. 3. Do not use the recorder where there is high vibration or high magnetic field. This could cause damage to the recorder or errors in measurement. 4. Disconnect power prior to any maintenance or repair in order to avoid personal injury and/or damage to the unit. 5. In areas with conductive pollution, adequate ventilation, filtering and sealing need to be installed. 6. When cleaning the recorder, handle carefully and use a soft dry cloth. Avoid the use of abrasives or any sharp and hard objects which would damage the display. 7. Do not operate the recorder if any part has been removed or disassembled. Consult your nearest dealer at once.
Static Electricity Appropriate precautions must be taken when handling the recorder. The circuit board and components are susceptible to damage caused by electrostatic discharge. Take static electricity precautions while handling and inserting the Compact Flash Card into the recorder. To replace the power-line fuse The power-line fuse is located within the fuse-holder on the power board. For 90-250 VAC line voltages, the user must use a 2.5A time-lag fuse, and for either 11-18 VDC or 18-36 VDC line voltages, a 5.0A time-lag fuse must be used.
-2-
Safety
DC Supply
http://www.chromalox.com
General Description
-3-
http://www.chromalox.com
Model ECR1 Electronic Chart Recorder Basic Configuration ECR1 Code Power 4 90-250 VAC, 47-63 Hz 6 11-18Vdc 7 18-36Vdc Code Analog Input Card 0 None B 12 Channels (4 Cards*) 3 3 Channels (1 Card*) C 15 Channels (5 Cards*) 6 6 Channels (2 Cards*) D 18 Channels (6 Cards*) A 9 Channels (3 Cards*) Code Digital Input Card 0 None 1 6 Channels (1 Card*) 2 12 Channels (2 Cards*) Code Digital Output Card 0 None 1 6 Relays (1 Card*) 2 12 Relays (2 Cards*) Code Communications 0 Standard Ethernet Interface 1 RS-232/ 422/485 (three in one)* Ethernet interface Code PC Software 1 Free Basic Observer I for non-communication application 2 Extensive Observer II for communication via RS-232/422/485 or Ethernet Code Firmware 0 Basic Function 1 With Mathematics, Counter and Totalizer Functions Code Storage Media 1 32MB Compact Flash Card (CF) 4 256MB Compact Flash Card (CF) Code Case/Mounting 1 Standard Panel Mount 2 Bench Top / Portable Style with Handle Code Special Option 0 None 1 24Vdc Auxiliary Power Supply (for Transmitter, 6 Channels) 2 3-Channel Analog Output 3 6-Channel Analog Output 4 8-Channel Analog Output 5 Panel Mounting with Power Plug 6 Panel Mounting with Power Switch ECR1 - 4 A 0 0 0 1 0 1 1 0 Typical Model Number
* Standard model without options, ECR1-4A00010110. * The rear slots of the recorder will only accept up to 6 cards in any combination.
-4-
http://www.chromalox.com
Accessories:
Part No. AI181, AI182, AI183 AI181V, AI182V, AI183V DI181 DO181 AP181 CM181 CM182 PM181 PM182 PM183 PM184 PM185 PM186 MK181 MK181B MK183 MK183B MK184 MK184B CF032 CF256 CF1000 AS181 AS182 AO183I AO183V BT181 BT182 SC181 SNA10A UMECR1 Description 1, 2, 3-channel analog input card (TC, RTD, +mA, +V, +mV) 1, 2, 3-channel voltage input card ( mA, V, mV only) 6-channel digital input card 6-channel relay output card (AC/DC) 24 VDC auxiliary power supply card for 6 transmitters RS-232/422/485 + Ethernet communication module Standard Ethernet communication module 90-250 VAC, 47-63 Hz power supply 11-18 VDC power supply module 18-36 VDC power supply module 90-250 VAC, 47-63 Hz power supply with power plug 36-72 VDC 47-63 Hz power supply 20-28 VAC power supply Panel mount assembly kit (grey color) Panel mount assembly kit (black kit) Bench top / portable handle assembly kit (grey color) with USA Cable Bench top / portable handle assembly kit (black color) with USA Cable Bench top / portable handle assembly kit (grey color) with Europe Cable Bench top / portable handle assembly kit (black color) with Europe Cable 32MB compact flash card 256MB compact flash card 1GB compact flash card Basic PC software Observer I Extensive PC software Observer II 3-channel current output card 3-channel voltage output card Boot ROM without Math, Counter & Totalizer Boot ROM with Math, Counter & Totalizer Slot cover of an empty slot RS-485 to RS-232 converter User Manual
Notes: The rear slots of the recorder will only accept up to 6 optional cards of input, output or 24 VDC power supply in any combination. For example, 12-channel analog input needs 4 pcs. of 3-channel analog input cards AI183. Two empty slots would be available for other cards. The basic PC software Observer I is supplied free recorder. There is an additional charge for the extensive PC software Observer II which is required for communication via RS-232/422/485 or Ethernet.
-5-
http://www.chromalox.com
-6-
http://www.chromalox.com
2.1 Unpacking
If any damage is found while unpacking, the user should contact the local representative at once. It is suggested that the special packaging is retained for possible future use.
2.2 Installation
Remove stains from this equipment using a soft, dry cloth. Do not use harsh chemicals, volatile solvent such as thinner or strong detergents to clean the equipment in order to avoid deformation or decoloration. The recorder is designed for indoor use and not in hazardous areas. It should be kept away from shock, vibration, and electromagnetic fields such as variable frequency drives, motors and transformers. The ECR1 peperless recorder is intended for operation in the following environment: Pollution Degree Level II Temperature Humidity Power Panel Mounting Style
166mm (6.54 in.)
20mm (.79 in.) 174mm (6.85 in.) 157mm (6.18 in.)
IEC1010-1(EN61010-1) 5 ~ 50C 20 ~ 80% RH (non-condensing) 90 ~ 250 VAC, 50/60 Hz, 11-18 VDC or 18 - 36 VDC
Note: Do not over-tighten mounting clamp screws as it could result in distortion of the case. There is no mounting angle restriction. 2006 Chromalox, Inc. -7-
http://www.chromalox.com
Figure 2 - 4
Figure 2 - 5
Figure 2 - 6
Figure 2 - 7
http://www.chromalox.com
Holding the handle so that the instruction side is visible, pull the handle outward using both hands and put it in a vertical position on top of the case. Then, slide the handle into both ears as Figure 2-9 illustrates. Rotate the handle downward as shown in Figure 2-10 & 2-11. Lastly, slide both feet beneath the case and straighten up the stoppers as shown in Figure 2-12 through Figure 2-14. The bench top recorder is now mechanically ready.
Figure 2 - 9
Figure 2 - 10
Figure 2 - 11
Figure 2 - 12
Figure 2 - 13
Figure 2 - 14
Note: To change the bench top into panel mount. Disassemble kit MK184 (one handle, two feet, and two ears) in reverse of above, then fit the mounting clamps. 2006 Chromalox, Inc. -9-
http://www.chromalox.com
Figure 2 15
Analog input card (part numbers AI181, AI182, AI183) AI181, AI182, AI183 are analog input cards with 1, 2 or 3 channels respectively. Each card includes universal TC inputs (J, K, T, E, B, R, S, N, L), PT100, mV, mA and V. To select a specific input, first set jumpers and switches according to the sticker information on the card as shown in Figure 215, and plug it into the rear slot. Then, turn on the power to the unit. The recorder will automatically detect the card and display the specific input type, then show its source of a specific slot in Configuration Mode. All inputs were initially set for 4-20mA from the factory.
Digital Output card (DO181) / 6 relay alarm card The digital output card includes 6 relays rated 5 Amp/240 VAC. Plug the card into rear slot and power on. The recorder will automatically detect the card and then display the output type and its source of the specific slot in System Info mode while doing the configuration. To set up the digital output card, please refer to Event, Job in Section 4.1 of this manual.
Digital Input card (DI181) This card includes 6 event input channels 1, 2, 3, 4, 5 & 6. As above, plug the card into rear slot and turn the power on. The recorder will automatically detect the card, and then display the input type and its source of the specific slot in System Info mode while doing the configuration.
24 VDC auxiliary power supply card (AP181) This card can supply power to 6 transmitters. The output rating is 24 1 VDC, 30mA each channel.
- 10 -
http://www.chromalox.com
- 11 -
http://www.chromalox.com
RS-232 Wiring
PC
9-pin RS-232 port 9-pin RS-232 port
Recorder
RS-232 Cable
Figure 2 21
- 12 -
http://www.chromalox.com
RS-485 Wiring
TX1
TX1 TX2
Recorder
TX2
PC
RS-232 Cable
TX1
Recorder
TX2
. . . . . . . . . . . . . . . . . . .
Recorder
TX1 TX2
Figure 2 22
- 13 -
http://www.chromalox.com
After installation and wiring, turn on the power to the recorder. Six soft keys: Page, Mode, History, Event, Status and Exit will appear on the left side of the LCD display. When the plastic cover at the front of the recorder is opened, the user will find another set of five soft keys: Dump, Clear, Operate, Config and Shutdown. These are the eleven soft keys used for operation. In the top right corner, small icons of buzzer, evnt, mem, CF and Date/Time display ECR1 status.
3.2 Mode
The Mode key defines the type of display. The options are Mix, Trend, Bar or Digital mode. Mix: The default display is Mix mode. Several modes can be mixed together including horizontal/ vertical trend, bar and digital modes.
Trend: Press the Mode key to display Trend mode. This is measured data trend in real time. The same page/ display may have a maximum of 6 trends in different colors. The user may define each color (details in Section 4.2 Display.) Bar: Press the Mode key again in order to display the bar mode shown in different colors. The scale of each bar can be defined individually, as detailed in Section 4.2 Display.
Digital: Press the Mode key again in order to display the digital process readouts in different colors. Press the Mode key again to return to the original Mix mode.
3.3 History
Press the History key to display a historical trend. Press the directional keys to move backward or forward. Press Zoom key to zoom in the time scale. It may be zoomed in for 9 minutes, 1 hour, 12 hours, one day or one week. Press Back key to return to the original display.
- 14 -
Basic Operation
Figure 3 1
http://www.chromalox.com
3.4 Event
Press the Event key and the Event / Alarm List will display general Events, Alarms and Reports. Press the Mode key to toggle between an Evnt/Alarm (Event/ Alarm) screen or a Report screen.
Event/Alarm The Event / Alarm screen displays information on the Type, Source, Active time, Clear time and Value of events or alarms. Use the directional keys to move downward or upward. Press the Ack All key to acknowledge all alarms. Events do not need to be acknowledged. Press the Back key to return to the original display.
Figure 3 2
On the Event / Alarm List, three different colors indicate the status of alarms. Red - Presently in alarm status. Green The cause of alarm status was temporary, and has now returned to normal. Grey A temporary alarm (in green status), after having been acknowledged, then becomes grey. The Active Time Column displays the time that an alarm status became active. Clear Time displays the time when the two following conditions are met. First, the alarm status is cleared and becomes normal, and second, the user has acknowledged the alarm. Once an alarm occurs, the red buzzer icon on the top right starts flashing. Once the alarm condition has expired and the alarm is acknowledged, then the red buzzer icon disappears. When the Clear Time column shows Terminated this indicates that the alarm has been terminated by turning off the power.
Report Press the Mode key to choose the Report Function. This produces Counter and Totalizer reports (when used). Press the Report key to select the report on a daily, weekly or monthly basis. Press directional keys to choose the exact day, week or month.
3.5 Status
Figure 3 3
The Status key brings up a list that displays the present status of Digital Inputs (DI), Digital Outputs (DO) Alarm Relay and the Counter and Totalizer. Press the Mode key to choose either DI, DO, Counter or Totalizer. This display shows the DI, DO, Counter or Totalizer status at the present time.
3.6 Exit
Press the Exit key to close the existing operation, the soft keys on the left hand side will disappear giving a full display. Press any soft key on the left hand side, and the six soft keys: Page, Mode, History, Event, Status and Exit will appear again. Open the plastic cover at the front lower side of recorder, then another set of five soft keys Dump, Clear, Operate, Config & Shutdown appear.
- 15 -
http://www.chromalox.com
3.7 Dump
Before removing the CF card from the recorder, it is necessary to press the Dump key to transfer the measured data and events from the internal memory of the recorder to the CF card.
3.8 Clear
When the internal memory is down to 25%, the mem icon on the top right changes color from green to red. Also, when the internal memory reserved for events is down to 25%, the evnt (event) icon on the top right changes color from green to red. In each case the user should transfer all measured data from the recorder to the CF card by pressing the Dump key as above. However, if the measured data and events are not significant information, the user may also press the Clear key to clear them.
3.9 Operate
Press the Operate key to start a job manually. For example: to record the alarm by selecting Log alarm. There are various jobs that may be assigned, as described in Event, Job of Section 4.1 Channel of this manual.
3.10 Config
Details about the soft key Config are described in Section 4 Configuration.
3.11 Shutdown
Accidental turning off the power will cause loss of data and will interrupt the operation of the recorder. Therefore press the Shutdown key to shutdown the system first before turning off the power.
Figure 3 4 Buzzer: Evnt: Appears by flashing in red whenever an alarm status occurs. The buzzer will disappear after the user acknowledges the alarm, or the process becomes normal. The percentage of memory space left for events/alarms. For example, evnt 84% means 84% of memory space is remaining for events/alarms. Refer to Event/Alarm Limit in Section 4.4 Instrument. Various numbers of events/alarms can be set. The icon flashes red when memory space is down to 25 %. The icon returns to normal (green) after pressing the soft key, either Dump or Clear. The percentage of memory space left for measured data. The icon starts flashing red when the memory space is down to 25%. The icon becomes normal (green) after pressing the soft key either Dump or Clear. If the internal memory goes down to 10 %, the earliest (oldest) measured data and events will automatically be saved to the CF card in small batches automatically. If no CF card is inserted, then the earliest (oldest) measured data and events will be overwritten and replaced by the latest measured data and events. This icon shows the status of the Compact Flash card. If a CF card is not inserted, the icon shows a red-cross sign. If it is properly inserted, then the icon displays as normal (green) and indicates the percentage of memory space left on the CF card. The icon starts flashing in red when the available memory space goes down to 25%. The icon returns to normal (green) after downloading data and events from the CF card to the PC. If the CF card is inserted in the recorder and its memory is full, then the memory of CF card remains unchanged and the earliest (oldest) measured data and events on the recorders internal memory will be overwritten and replaced by the latest measured data and events.
mem:
CF:
Date/Time: To set the local time, please refer to Section 4.5 Clock.
- 16 -
http://www.chromalox.com
Press the Config key to enter the Configuration mode. The following buttons appear: Channel, Display, Tools, Instrument, Clock, System Info and Demo. Meanwhile, the following soft keys appear at the bottom: Save, Load, Default and Back.
Soft Keys Enter: Save: First select the mode by pressing directional keys then press Enter key to enter any mode of Channel, Display, Tools, Instrument, Clock, System Info or Demo. This saves the ECR1 configurations from the recorder to the CF card. To read the configuration and measured data from a CF card on a PC for the first time, or any time configuration has been changed, it is important to press the Save key to save ECR1 configuration changes to the CF card beforehand. Load configuration from storage media CF card to recorder.
Load:
Default: If the configuration is set incorrectly, Default is a useful key to recall the default settings on the analog input card inserted into rear expansion slot. Back: Go back to the previous display.
Configuration
Figure 4 1
- 17 -
http://www.chromalox.com
4.1 Channel
After entering the Configuration mode, select Channel and press the Enter key to get into Channel mode. Press the AI, DI or Math keys to edit the Analog input, Digital input or Mathematics setup. The directional keys < > at the bottom allow the user to select a single channel. Press the directional keys on the left side to select specific fields. After Configuration 4.1 to 4.6, press Back key to return to real-time display, all configuration changes will be automatically saved.
Name: This field defines the name for each channel. The name is restricted to six characters. Press Enter and a keyboard will appear. BackSP key means backspace, Select key means to select a character or number, Caps on means characters in capital, and Caps off means characters not in capital. Desc: The description about a specific channel on the display. Log Method: The method of logging measured data. Select the column, and then choose the Log method of Instant, Average, Minimum, Maximum or Disable.
Figure 4 2
Instant: Logs in the latest data measured at the selected sampling interval Average: Logs in averaged data measured at the selected sampling interval Minimum: Logs in minimum data measured at the selected sampling interval Maximum: Logs in maximum data measured at the selected sampling interval
Log Speed: The speed or frequency at which data is measured: 1, 2, 5, 10, 30, 60 or 120 seconds. Offset: The value used to correct sensor input error. Gain: A multiplier used to correct sensor error. Value correction = (the process value + offset) x gain Input: Displays the type of sensor that is configured through DIP switch configuration. (V, mV, mA, T/C, (J, K, T, E, B, R, S, N, L), PT100, JPT100) Unit: The engineering unit of input. Range: Various input ranges can be set for voltage and current. Options are 0-1, 1-5, 0-5 or 0-10 V for voltage, and 0-20 or 4-20mA for current. Scale:
> Scale Unit: Defines a unit of measure. > Scale Low: Defines low scale with decimal if necessary. For instance, input 0-10 V, the Scale Low can > Scale Hi:
be set up with value 0.00 to be correspondent to low range 0 V. Defines high scale with decimal if necessary. For instance input 0-10 V, the Scale Hi can be set up with value 100.00 to be correspondent to high range 10 V.
- 18 -
http://www.chromalox.com
Event The Event is frequently used for Alarm purposes. Event can also be used for Digital Output (DO), Timer, Totalizer, Counter or Report functions. Type: There are various event configurations that can be selected for an Alarm or job purpose. Choices are H, L, HH, LL, R or r. H: High limit. When the process exceeds high limit, the alarm or job is actuated. L: Low limit. When the process drops below low limit, the alarm or job is actuated HH: High high limit, sets up another limit higher than high limit for double warning. LL: Low low limit, sets up another limit lower than low limit for double warning. R: Increasing rate of change. The job or alarm is actuated when the rate of increasing process value is greater than the specified rate time interval. For example, when the Setpoint is set to 100_1S, if the process is increasing greater than the value of 100 in 1 second, then the job or alarm will be actuated. r: Decreasing rate of change. The job or alarm is actuated when the rate of decreasing process value is greater than the specified rate time interval. For example, when the Setpoint is set to 50_2S if the process is decreasing greater than the value of 50 in 2 seconds, then the job or alarm is actuated. Setpoint: A fixed value for actuating Job1 and /or Job2. Job1, Job2: When an event occurs, the task to be performed is called the job. A typical example is to trigger an alarm buzzer in the event of high temperature. Each pen can accept four events (or alarms) and each event can create two jobs. Please note that a job under an Event is different from a job by pressing the Operate key. The former is actuated by an event, and the latter is actuated by manual control, no event necessary. Various types of jobs can be selected: No Action: Do nothing. Log Alarm: Record alarms. Log Event: Record events. Sound Buzzer: Sound the buzzer. It stops once any key is pressed. DO Latch On: Set digital output / relay on, and then select Target from DO 1 to DO 6. The relay is latched when it is activated. DO Latch Off: Set digital output / relay off, and then select Target from DO 1 to DO 6. The relay is latched when it is activated. DO Process: Set digital output / relay on for process high or low, and then select Target from DO 1 to DO 6. The relay is not going to be latched when it is activated. Enable Timer: Start the timer, and then select Target from Timer 1 to Timer 6. Disable Timer: Stop the timer, and then select Target from Timer 1 to Timer 6. Preset Totalz: Start the totalizer with a preset value, then select Target from Tolz 1 to Tolz 6. Reset Totalz: Reset totalizer to zero, and then select Target from Tolz 1 to Tolz 6. Enable Totalz: Start the totalizer, then select Target from Tolz 1 to Tolz 6. Disable Totalz: Stop the totalizer, then select Target from Tolz 1 to Tolz 6. Preset Counter: Start the Counter with a preset value, then select Target from Cont1 to Cont6. Reset Counter: Resets the counter to zero, and then select Target from Cont1 to Cont6. Inc Counter: Increase the counter, and then select Target from Cont1 to Cont6. Dec Counter: Decrease the counter, and then select Target from Cont1 to Cont6. Log Report: Make the report for Counter and Totalizer. Choose this column, and then the report will be presented as details described in section 3.4 Event.
- 19 -
http://www.chromalox.com
Note: The internal sampling rate of the recorder is fixed at 200 milli seconds. i.e. the ECR1 samples data 5 times per second. If the logging speed is set at 1 second in Instant mode, the recorder logs using the last of five measured data values. For the same speed in Averaging mode, the recorder logs using the average of the five measured data values. For the same speed in the Maximum or Minimum mode, the recorder then logs using the maximum or minimum of the five measured data values. Sampling Instant Averaged Maximum Minimum 200mS 200mS 200mS 200mS Logging (historical trend) the last of 5 measured data the average of 5 measured data the maximum of 5 measured data the minimum of 5 measured data Display (real time) the last of 5 measured data the last of 5 measured data the last of 5 measured data the last of 5 measured data
_ Press Back key to return to real-time display, all configurations will be memorized
4.2 Display
Press the Back key to return to the beginning of the Configuration mode. Select Display and press Enter to get into the Display mode. Each display may have a maximum of 6 pages and each page may display a maximum of 6 channels. Mode: Defines the method of displaying data. Options are: Mix, Trend, Bar or Digital modes. Trend Dir: Selects the trend direction: horizontal or vertical. Background: Defines the background color of Trend mode in black or white Pen: Defines a drawing pen for each specific channel. Its color, width, Display Hi and Display Lo can be altered. Channel: Selects a specific analog input (AI) Mathematics (Math) or selects Disable if a specific channel is not required. Color: Selects the color for each pen. Width: Selects the width of each pen, 1-thin, 2-medium, 3-wide. DisplayLo: Defines the low scale for a pen on the display. DisplayHi: Defines the high scale for a pen on the display. Figure 4 4 StatusBar: For convenience, when viewing the status of the Totalizer, Counter, DI or DO., the user may enable these items to appear in the StatusBar. For example, after enabling Totalizer 1_3, an extra bar will appear at the lower part of display which displays the values for Totalizers 1, 2 and 3. Note: To illustrate the difference between DisplayHi, DisplayLo and Scale Hi, Scale Low. Here is a typical example, with input 0-10V, Scale Low=0.00, Scale Hi=100.00, to show higher resolution, set DisplayLo=0.00, DisplayHi=50.00 so that the Bar displays from value 0.00 to 50.00. The decimal point is defined by Scale Hi and Scale Low, and not by DisplayHi, or DisplayLo. - 20 2006 Chromalox, Inc. Figure 4 3
http://www.chromalox.com
Counter Press directional keys < > at the bottom to select from 6 available counters. Name: Desc: Unit: Preset: Defines the name of counter. Defines the description for a specific timer on the display. Defines the unit of timer Defines the preset value for the counter. The counter starts from a preset value. Defines the type, setpoint, Job1 or Job2. Select one of three options: None, Process Hi, Process Low Defines the set point of process value to trigger the counter. Figure 4 6
Job1, Job2: Various jobs as described in Section 4.1 Channel, 2 jobs for each counter
- 21 -
http://www.chromalox.com
Totalizer Press directional keys < > at the bottom to select from 6 available totalizers. Name: Defines a name of the totalizer. Desc: Defines the description for a specific totalizer on the display. Source: Select a specific analog input or Math input to be used for totalizing. Action: Disables or enables the totalizer. Decimal: Defines the decimal point for the totalizer. Period: Selects second, minute or hour rate used for the totalizer. Unit: Defines the units used for totalizing Preset: Defines the preset value for the totalizer. The totalizer starts from a preset value. Type: Select one of three options: None, Process Hi, Process Low Setpoint: Defines the set point in which to trigger a totalizer event. Job1, Job2: various jobs as described in Section 4.1 Channel, 2 jobs for each totalizer. An example using the Totalizer: A factory operates for 8 hours a day, and the staff wishes to get the total volume of production using daily, weekly and monthly reports. First, the user needs to enter into Tools mode, modify the settings as follows, the totalizer will then compile from 8:30 am, and stop at 17:30 pm daily. After production has finished, the user performs the following: press the Event key on the left hand side, and press the Mode key to select Report mode. Finally, press the Report key to choose a daily, weekly or monthly report format. Timer1 Type: Daily Action: Enable Time - Hour: 8 Min: 30 Job1: Reset Totalz Target: Tolz1 Job2: Enable Totalz Target: Tolz1 Timer2 Type: Daily Action: Enable Time - Hour: 17 Min: 30 Job1: Disable Totalz Target: Tolz1 Job2: Log Report Target: Tolz1 Totalizer Name: xxxx Source: AI1 Period: Min Event No Type 1 Hi 2 Low Desc: xxxxxxxxxxxxxxxxx Action: Enable Decimal: 1 Unit: xxxx Preset: 0.0 Setpoint xxxx xxxx Job1 Log Alarm Log Alarm Job2 Set DO on Set DO off Figure 4 7
As an example, a report an be set up to display the following information: The weeks production volume: Monday: 990, Tuesday: 1010, Wednesday: 1020, Thursday: 1020, Friday: 980 respectively. The weekly report shows production volume 5,020.
- 22 -
http://www.chromalox.com
4.4 Instrument
The BACK key will return the ECR1 to Configuration mode. Select Instrument then press the Enter key to get into Instrument mode. Instrument Name: Assigns a name for the recorder. Password: Defines a security password. (8 characters maximum). Once the password has been entered, the user needs to key in the password whenever Config, Dump, Clear or Operate soft keys are required. These keys enable the user to configure, dump data, clear data or manually operate a job. Storage Media: Figure 4 8 CF card: Store historical measured data on a Compact Flash memory card. The recorder is supplied with a standard 16MB CF card, and higher capacities of 64, 128MB CF cards can be supplied on request. KeypadSound: Selects the following four options: disable, minimum, medium or maximum. DateStyle: Selects either month/date/year or date/month/year format. Language: The English version is available, other languages will be available in a future version. Event/Alarm Limit: Selects a high-limit of events/alarms that can be sent. Limit options are 256, 512 or 1024. LCD: Screensaver: To prolong the life of the LCD display, we suggest that the display turn-off time is set to 1, 10, 20, 30, 40, 50 or 60 minutes. The recorder continues to read data while it is in the Screen Saving mode. The display turns on again by pressing any soft key. When an alarm occurs, it turns on the display as well. IR detector: The Infrared detector works with the Screensaver to protect the LCD. The Infrared detector senses the movement of body temperature when a user gets close or walks away. (Range approximately 2 meters). Operation is as follows: Set the IR Sensor to On and Screensaver at 1 Min. The display will turnoff in 1 minute after the user walks away from the recorder. Once the Infrared detector senses heat movement within 2m of the recorder, display turns on without pressing any keys on the recorder. Note: The IR (Infrared) detector needs to work together with Screensaver, it cannot function alone. However, the Screensaver can function alone after the IR Sensor is disabled. Communication PCTransfer: Selects RS-232, RS-485, or standard Ethernet communication. RS-232, RS-485: Address: 0 to 31 nodes for RS-485 BaudRate: Selected from various Baud rates 1200, 2400, 4800, 9600, 19200 or 38400. DataFormat: Select from one of four data formats. Ethernet: IP: Select Automation if the server on the network will automatically assign the IP address for the recorder. Select User Define to manually set a fixed address to the recorder. Two columns will appear for keying in fixed addresses IP Address: Defines the correct address of the recorder on the network SubnetMask: Defines the correct SubnetMask address on the network DefaultGateway: The Gateway IP address on Ethernet. Note: If Automation is selected, the IP address and SubnetMask are invisible. The IP address can be viewed in the System Info mode under Configuration. Because an IP address may be re-assigned a new address by the server after power is switched off and on, the user defining fixed addresses is recommended. 2006 Chromalox, Inc. - 23 -
http://www.chromalox.com
4.5 Clock
Press the Back key to return to the Configuration mode. Select Clock then press the Enter key to get into Clock (Date/Time) mode to set up the local time. After setting up the Date/Time, use directional keys to go to the Apply column, then press the Enter Key.
Figure 4 9
4.7 Demo
The Demo mode is a simulation used for demonstration purposes. It will simulate 18 AI analog inputs, 18 Math functions, 6 DI digital inputs and 6 DO digital outputs. The trends are simulated by SIN waves. To start the Demo mode, turn the power off and on. To stop the Demo mode and return to real mode, connected with real inputs, turn the power off and on once more.
- 24 -
http://www.chromalox.com
- 25 -
http://www.chromalox.com
Observer I & Observer II are PC software packages to be used with the recorder. They are Windows 98, NT, 2000 and XP compatible to archive and analyze measured data, and configure the recorder from a PC. Their different applications are: ECR1 without communication Observer I Basic software, supplied for free on recorders without communications Extensive software, offered with recorders using communications such as Ethernet or RS-232/422/485
5.2 Set up
To set up the software on a PC, insert the CD, double click the Setup program and follow the step by step instructions.
- 26 -
Observer II
http://www.chromalox.com
Note: Ethernet is the standard communications offered with this instrument. To enable Ethernet functionality, the extensive software Observer II package is required.
To set up PC software Observer II, the IP address of the recorder must be keyed in. This IP address can be
found in Section 4.6 System Info mode under Configuration.
The configuration of the Real-time Viewer is set up through the PC. This is different from the configuration of
Historical Viewer which requires the same setup as the recorder.
- 27 -
http://www.chromalox.com
Configuration: Enter Configuration, click the icon New name, and then choose CF card or Ethernet.
a. If using a CF card, click the icon File , and select the file path of the CF card. A question appears Do you want to receive configuration data now? Before confirming, the user needs to Save configuration and Dump measured data from the recorder to the CF card, then insert the card into a CF reader connected to a PC. After confirmation, the PC will receive configuration data from the CF card. In the configuration table, the user may review configuration by clicking the icons of Channel , Display , Tools , Instrument and System Information . This configuration is used by the Historical Viewer to read historical data and trends. If necessary, the user may alter the configuration on the PC and Send configuration changes to the CF card, then Load it to the recorder. Anytime the configuration of the recorder is altered, the PC can and must receive the configuration updates from the recorder via CF card. b. For Ethernet, click the icon File , then key in the IP address of the recorder. A question appears - Do you want to receive configuration data now? After confirmation, the PC will receive configuration data from the recorder via Ethernet. In the configuration table, the user may review the configuration by clicking the icons of Channel , Display , Tools , Instrument and System Information . If necessary, the user may alter the configuration on the PC and Send configuration back to the recorder. This configuration is used by the Historical Viewer feature to read historical data and trends.
Historical Viewer: Enter the Historical Viewer and open the project file under Configuration as above. Click the icon Import Measured Data to import measured data from the CF card or from the recorder via Ethernet. After the importing procedure, a trend will be displayed. Click the icon to show an Even/alarm list. to print via PC. to choose the Page number. to export data in Excel format. to copy curves to a clipboard. or White to choose a black or white background. to display horizontal or vertical trends. to zoom out and zoom in on trends. or Vertical or Zoom In Click the icon Print Click the icon Page Click the icon Export Click the icon Copy Click the icon Black
Click the icon Horizontal Click the icon Zoom Out Click the icon Zoom Cancel Click the icon Seek by time Click the icon
to display the trend from the beginning to the end on one full page. to display the trend at a specific time. to search for a specific event or alarm.
- 28 -
http://www.chromalox.com
Real-time Viewer: Enter into Real-time Viewer segment. Click the New icon for a new project, enter the new project name, then key in the IP address of the recorder. If more than one recorder is being used, key in their IP addresses and press + button to put them all in the IP list. The PC will automatically receive new configuration settings from the recorder. For real-time monitoring, the user could use the original configuration and make no changes. If necessary, the user may change the following configurations: Tag name, Log speed, Log method, Unit and Alarm in active color. Options in inactive colors may not be changed. The real-time data is displayed in the following four formats: digital, bar, trend and alarm list. Click the icon to display the measured data collected and stored by the Real-time Viewer in Trend mode. Click to display the Real-time Viewer in Cascade mode. Click the icon to mute, which silences the alarm. Click again to restore alarm sound. The configuration of the Real-time Viewer may or may not be consistent with the configuration of Historical Viewer.
- 29 -
http://www.chromalox.com
With the Math option, the following Math functions are available in the Channel mode of configuration. The equations can be used to produce mathematical solutions by using measured data or computed data as variables. The results can be displayed and stored. The Math expression / equation can be keyed in up to a maximum of 36 characters.
An example of Math Set up a Math channel after setting up three analog inputs. In Channel mode, press the Math key to get into a Math channel. Assign the Name, Description, Enable Type, define Log Speed, Log Method, and do Math Expression / Equation. Then, select Display mode. Configure mode, Trend Direction and Background color. If Pens 1, 2 and 3 have been used for three analog inputs, then select Pen 4 to be used for Math. Press the Enter key under the Channel column of Pen 4, then select MATH1. Define Color, Width of the trend, DisplayHi and DisplayLo. Press the Back key twice to return to the beginning of the display and all configurations will be memorized. The Math function has now been initialized.
- 30 -
Mathematics
http://www.chromalox.com
Specifications
2.6C /ohm of resistance difference of two leads 2.6C /ohm of resistance sum of two leads 200nA 120dB 55dB 430VAC min. Sensor opened for TC, RTD and mV inputs, below 1 mA for 4-20mA input, below 0.25V for 1-5V inputs, unavailable for other inputs Within 10 seconds for TC, RTD and mV inputs, 0.1 second for 4-20 mA and 1-5V inputs
- 31 -
http://www.chromalox.com
Characteristics: Type J K T E B R S N L PT100 (DIN) PT100 (JIS) mV mA 0~1V 0~5V 1~5V 0~10V Digital Input Card (DI181) Channels: Logic Low: Logic High: External pull-down Resistance: External pull-up Resistance: Digital Output Card (DO181) Channels: Contact Form: Relay Rating: Range -120 ~ 1000C (-184 ~ 1832F) -200 ~ 1370C (-328 ~ 2498F) -250 ~ 400C (-418 ~ 752F) -100 ~ 900C (-148 ~ 1652F) 0 ~ 1820C (32 ~ 3308F) 0 ~ 1768C (32 ~ 3214F) 0 ~ 1768C (32 ~ 3214F) -250 ~ 1300C (-418 ~ 2372F) -200 ~ 900C (-328 ~ 1652F) -210 ~ 700C (-346 ~ 1292F) -200 ~ 600C (-328 ~ 1112F) -8 ~ 70mV -3 ~ 27mA -0.12 ~ 1.15V -1.3 ~ 11.5V -1.3 ~ 11.5V -1.3 ~ 11.5V Accuracy at 25C 1C 1C 1C 1C 2C (200 ~ 1820 C) 2C 2C 1C 1C 0.4C 0.4C 0.05% 0.05% 0.05% 0.05% 0.05% 0.05% Input Impedance 2.2M 2.2M 2.2M 2.2M 2.2M 2.2M 2.2M 2.2M 2.2M 1.3K 1.3K 2.2M 70.5 332K 332K 332K 332K
6 per card -30V minimum, 0.8V maximum 2V minimum, 30V maximum 1K maximum 1.5M minimum 6 per card N.O. (form A) 5A/240 VAC, life cycles 200,000 for resistive load
24VDC Auxiliary Power Supply Card ( AP181) Channels: to be used for 6 transmitters Output Rating: 24 1 VDC, 180mA in maximum, 30mA / each channel COMM Module (CM181) Interface: Protocol: Address: Baud Rate: Measured data Bits: Parity Bit: Stop Bit: RS-232 (1 unit), RS-485 or RS-422 (up to 247 units) Modbus Protocol RTU mode 1-247 0.3~38.4 Kbits/sec. 7 or 8 bits None, Even or Odd 1 or 2 bits
Standard Ethernet Communication Protocol: Modbus TCP/IP, 10 Base T Ports: AUI (Attachment Unit Interface) and RJ-45, Auto- detect capability Infrared Detector Distance: Time delayed: Detect moving human body in distance around 2 meters 10, 20, 30, 40, 50 or 60 minutes to be defined
- 32 -
http://www.chromalox.com
Environmental & Physical Operating Temperature: Storage Temperature: Humidity: Altitude: Insulation Resistance: Dielectric Strength: Vibration Resistance: Shock Resistance: Operation Position: Dimensions: Panel Mount style: Bench Top style: Standard Panel Cutout: Approval Standards Safety:
5 ~ 50C -25 ~ 60C 20 to 80% RH (non-condensing), maximum relative humidity 80% for temperature up to 31C decreasing linearly to 50% relative humidity at 40C 2000 M maximum 20 M ohms min. (at 500 VDC) 3000 VAC, 50/60 Hz for 1 minute 10-55 Hz, 10m/ s_ for 2 hours 30m/ s_ (3g) for operation, 100g for transportation no inclined restriction 166(W) x 144(H) x 174mm(D) 166 (W) x 192 (H) x 194mm (D) DIN size in 138 x 138mm
UL61010C-1, CSA C22.2 No. 1010.1-92 EN61010-1 (IEC1010-1) over voltage category II, Pollution degree 2 IP 30 front panel for indoor use, IP 20 housing and terminals
EN50081-1, EN61326 (EN55011 class B, EN61000-3-2, EN61000-3-3) EN50082-2, EN61326 (EN61000-4-2, EN61000-4-3, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-11, EN50204)
7.2 Communication
The standard communication interface is Ethernet with protocol IEEE 802.3 - 10 Base T. Other options are RS-232 / RS-422 / RS-485.
- 33 -
http://www.chromalox.com
Chromalox, Inc. 103 Gamma Drive Pittsburgh, PA 15238 Phone: 1-888-996-9258 www.chromalox.com