Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Datasheet
Part numbers and prices: see pricelist
Vitotec folder, register 13
File in:
Benefits
& Highly efficient, direct flow vacuum tube collector. & Tubes can be rotated for optimum orientation towards the sun,
& Universal application through vertical or horizontal installation thereby maximising the energy yield.
in any location, either on rooftops or on walls. & Highly effective thermal insulation of the header casing for mini-
& Easy and reliable connection of individual tubes through a new mum thermal losses.
and innovative plug-in system & Easy assembly through the Viessmann fixing system and corru-
& The absorber surfaces, which are integrated into the vacuum gated stainless steel plug-in connectors.
tubes, are not susceptible to contamination. & The flow and return connection on one side through the integral
header inside the header casing minimises the pipework effort.
& Attractive collector design, connecting chamber in RAL 8019
(brown).
5822 127-6 GB
Specification
Type SD2, 2 m 2 SD2, 3 m2
Number of tubes 20 30
Gross area * 1 m2 2.88 4.32
Absorber area m2 2.05 3.07
Aperture area * 2 m2 2.11 3.17
Dimensions
Width a mm 1418 2127
Height b mm 2031 2031
Depth c mm 143 143
Optical efficiency * 3 % 80.6 80.6
Heat loss factor k1* 3 W/(m2 · K) 1.133 1.133
Heat loss factor k2* 3 W/(m2 · K 2) 0.0638 0.0638
Thermal capacity kJ/(m 2 · K) 25.5 25.5
Weight kg 51 76
Liquid content litres 4.2 6.2
(process medium)
Permissible operating pressure * 4 bar 6 6
Max. idle temperature * 5 °C 300 300
Connection Ø mm 22 22
Space requirement for flat roof installations m2 approx. 2.88 approx. 4.32
Requirements of base structure and fixings with sufficient ballast to counteract prevailing wind forces
KR Collector return
KV Collector flow
*1
Decisive when applying for subsidies.
5822 127-6 GB
*2
Decisive when sizing the system.
*3
Relative to the absorber surface area.
*4
The collectors must be pressurised in cold, sealed systems with at least 1.5 bar.
*5
The idle temperature is the temperature which occurs at the hottest part of the collector at 1000 W global radiation strength if no heat is
drawn off.
Accessories
Packed separately, subject to order: & Connecting cable, 1.0 m long, 2 pieces
& The fixing sets contain components required for the relevant & Solar heating system flow and return pipes
method of installation, such as: & Fill valve
– Timber & Fill station
– Roof hooks & Manual solar fill pump
– Mounting plates & Solar expansion vessel with shut-off valve
– Mounting rails & Pre-cooling vessel
– Clamping bracket, screws, nuts & Anti-freeze tester
& Connection pipes & Process medium
& Connection set with product documentation Non-toxic liquid for solar heating systems with active anti-corro-
& Sensor well set sion and anti-ageing protection
& Spare parts set (assortment of small parts which may be lost
Tested quality