Está en la página 1de 16

Machine

Roomless

Elevator

SIGMA constantly endeavors to improve products therefore the information in this catalog is subject to change without notice. 2006. 12 Printed in Korea

Truly your elevator partner

The Changwon Factory


The Changwon Factory in Korea, which is referred to as the single largest elevator plant, provides one-stop manufacturing of highest quality.
Annual production Capacity (as of 2006) - Elevator : 15,000 units - Escalator : 700 units

The Design Center


The Design Center in Korea provides perfect customer satisfaction by meeting any customer needs.

SIGMA in the world


SIGMA has been serving you in more than 70 countries around the world for over 35 years.

Established in 1995 10 aesthetic designers(as of 2006)

Accumulated Sales(as of 2006) - over 150,000 units

Architectural building design

Space savings

Construction cost savings

Energy savings

04

Innovative SIGMA MRL Elevator

05

Architectural building design


SIGMA`s machine roomless (MRL) elevator allows the building to be free from unsightly construction on the roof and provides more flexibility in building design.

Space savings
The structural design improves the net space of the car in any given hoistway and provides more rental areas within the building.

Construction cost savings


Our MRL solution allows the owner to save on construction work and materials. It also leads to the reduction of the total building cost.

Energy savings
The compact motor design not only uses a lower initial electricity load but it also consumes less energy than a conventional geared system.
PM Gearless Geared
Motor Efficiency Advantage of PM

Power(kW)

Customer Benefits

Customer-friendly
The implementation of state-of-the-art technology influences the values of a building by changing expectations and realities. SIGMA is committed to the ongoing pursuit of this objective, especially in creating the pride of a new hassle-free building, with safety, reliability, ride comfort and universal design.

14

Rated Efficiency

Innovative SIGMA MRL Elevator

15

Brake operation

E&I panel

SIGMA NeT

06

Innovative SIGMA MRL Elevator

07

Brake operation
The reliable double drum brake offers excellent brake operation in the downward and upward moving of the elevator without noise and shock.

E&I panel
The emergency and inspection (E&I) panel located on the top landing floor provides all of the controls necessary to perform rescue and inspection operations quickly.

SIGMA NeT
Through SIGMA NeT, which monitors elevator, escalator and movingwalks by internet-based software, our elevator not only provides a comprehensive and easy-to-use interface but also brings perfect quality to reality.

EMI Test
(Electro Magnetic Interference)

Vibration and Dropping Test

ESD Test
(Electro Static Discharge)

Burst Test

Customer Benefits

Safety and Reliability


SIGMA Elevator companys number one priority is safety. Our basic spirit to ensure safety is through control technology such as back-up solution, safety drive operation and more than 10 other safety devices. We execute more than 30 kinds of reliability tests. These intense quality assurance programs make fool-proof products from the design stage.

PM gearless machine

Sensitivity test

Smooth operation

08

Innovative SIGMA MRL Elevator

09

PM gearless machine
PM gearless machine

Highly efficient gearless traction systems with permanent magnet synchronous motor (PMSM) provide safe and stable rides with a minimum level of vibration and noise.

Sensitivity test
Customers may experience a robust elevator which has been proven in the door impact test and deflection test in conformity with international standards.
Deflection test We execute the deflection test with a force of 300N at a right angle to the door and car panel.

Force 300N

Smooth operation
Velocity

A high-switching speed of power device in the drive (IGBT) and VVVF control ensure a consistently smooth motion profile which results in a comfortable ride.
*VVVF (Variable Voltage Variable Frequency)

PM Gearless Geared

Time

Customer Benefits
SIGMA provides best-in-class ride quality on every lift that we install. A high-switching speed of power device in the drive(IGBT) reduces motor noise. Moreover, a door operator with VVVF control ensures silent door movement. The result of modern technology allows SIGMA to reduce vibration and noise to a minimum level. Customers define luxury as a swift, smooth and silent ride. Our seamless interface between tenant requirements and elevator performance meets the exact standards and high expectations of customers.

Ride comfort

Deflection test

Buttons

Handrail

OPB

Installation

10

Innovative SIGMA MRL Elevator

11

Universal Design

SIGMA Elevator company has a Design Center for creative and innovative product development to meet the various needs of customers. Our newly released ceiling and fixture fully contains brightness and luxury which represent the latest trends. SIGMA believes there is no boundary in the usage of this elevator. This kind of belief not only enhances the external finish of the elevator, but also enriches the essence of human life. We proudly recommend everyone to experience our innovative design and wide assortments with all your senses.

Newly designed round buttons offer an attractive shape with a distinctive feel

Thickness of handrail provides comfortable rest and stability

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + + +

+ + + +

+ + + +

+ + + +

+ + + +

OPB with tactile buttons enables the handicapped to easily recognize items

Fixture installed at the proper height allows children to ride with freedom

Specification Ceiling OPB Wall Door Handrail Floor C-HX2 CBM-22C STS Hairline Etching (EW2-070) STS Hairline Etching (EH1-070) HR-04 Deco Tile

Specification

TECHNO MODERN

CONTEMPORARY MODERN

Ceiling OPB Wall Door Handrail Floor

C-HX3 CBM-22C STS Hairline Etching (EW2-059) STS Hairline Etching (EH1-059) HR-04 Deco Tile

12

Innovative SIGMA MRL Elevator

13

Specification Ceiling OPB Wall Door Handrail Floor C-NS1 CBM-22C STS Hairline Etching (EW2-060) STS Hairline Etching (EH1-060) HR-04 Deco Tile

Specification Ceiling CPI OPB Wall Door Handrail Floor C-NS2 CID-11 CBM-22 STS Hairline Etching(EW2-067) STS Hairline Etching(EH1-067) HR-04 Deco Tile

NATURAL MODERN

ROYAL MODERN

14

Innovative SIGMA MRL Elevator

15

ENTRANCE & CEILING

Our styles empower your riding experience by letting you change your elevator to customize the look of your building. From straight-out comfort to urban styling, SOLONTM appeals with new ventures.

Ground floor Jamb Wide Tapered Jamb with Transom Panel in STS Hairline Door STS Hairline Etching (No. EH1-067)

Sil Extruded Hard Aluminum Hall Indicator Hall Button Other floor Jamb Narrow Jamb in Painted Steel Sheet (No. LGM-922) Door Painted Steel Sheet (No. LGM-922) HID-A122 HBM-R45

Sill Extruded Hard Aluminum Hall Indicator & Hall Button VID-M652

Top floor Jamb Wide Jamb with in STS Hairline Door Painted Steel Sheet (No. LGP-934) STS Hairline

Landing Cabinet(Controller + E&I Panel) Sill Extruded Hard Aluminum Hall Indicator & Hall Button VID-M652

Standards

Luxury options (Additional Prices)

C-HX2
(Painted steel sheet color No.LGM-922)

C-HX3
(Painted steel sheet color No.LGM-922)

C-NS3
(Painted steel sheet color No.LGM-924+LGM-920)

C-MS2
(Painted steel sheet color No.LGM-921+Side White)

C-NS1
(Painted steel sheet color No.LGM-924+LGM-920)

C-NS2
(Painted steel sheet color No.LGM-924+LGM-920)

C-NL1
(Painted steel sheet color No.LGM-924+Stainless Mirror)

C-ML1
(Painted steel sheet color No.LGM-921+Center White)

16

Innovative SIGMA MRL Elevator

17

FIXTURES
Car Operating Board Hall Button Hall Position Indicator

HID-A132

HID-A122

HID-C132

Car Position Indicator

HBM-R45

VID-M652T

VID-M652

CID-10

CID-12

CID-11

Handrail
CBM-22C CBM-13C CBM-22 CBM-13 HBM-S43 VID-M632T VID-M632

Hall Lantern

HR-02

Handicapped COP
HLV-C08 HLV-630

HR-04

CBM-44SH

CBM-42SH

HBM-R65

HR-08

18

Innovative SIGMA MRL Elevator

19

ETCHING PATTERN

COLORS
Actual colors may be different from these prints.

LGM-921

LGM-922

LGM-920

EW2-043 EH1-043

EW2-059 EH1-059

EW2-060 EH1-060

EW2-062 EH1-062

EW2-063 EH1-063 LGM-930

White Pearl

LGP-928

EW2-064 EH1-064

EW2-067 EH1-067

EW2-069 EH1-069

EW2-070 EH1-070

EW2-071 EH1-071 LGP-004

LGP-927

LGP-944

LGP-924

EW2-072 EH1-072

EW2-074 EH1-074

EW2-075(BR) EH1-075(BR)

EW2-076 EH1-076

EW2-077 EH1-077

LGP-923

LGP-015

LGP-925

LGP-943

EW3-001 EH2-001

EW3-003 EH4-003

EW3-031 EH2-031

EW4-005 EH3-005

EW6-028 EH3-028

LGP-934

20

Innovative SIGMA MRL Elevator

21

OBSERVATION
1 Side View 2 Sides View

TECHNICAL DATA
Passenger Elevator Layouts
Hoistway Section Hoistway Plan (Center Opening)

3 Sides View

Hoistway Plan (Side Opening)

Overhead Height, Pit Depth


Speed(m/s) 1.0 1.5 1.75 Entrance Height(mm) 2100 2100 2100 Overhead(mm) 3750 3900 3950 Pit Depth(mm) 1150 1300 1400 Type of Buffer Poly-Urethane Hydraulic (oil) Hydraulic (oil)

22

Innovative SIGMA MRL Elevator

23

TECHNICAL DATA
Standard
Capacity Entrance Speed Opening Opening (m/s) Persons Load Type (mm) (kg) 6 8 9 1.0 10 11 13 15 17 6 8 9 1.5 10 11 13 15 17 6 8 9 1.75 10 11 13 15 17 450 550 600 680 750 900 1000 1150 450 550 600 680 750 900 1000 1150 450 550 600 680 750 900 1000 1150 2 Panel Center Opening 700 800 800 800 800 900 900 1000 700 800 800 800 800 900 900 1000 700 800 800 800 800 900 900 1000 Car Size Inside AN BN Outside AS BS Hoistway Size Top Beam Reaction Load(kg) Simplex AH 1750 1900 1900 1950 1950 2150 2200 2400 1750 1900 1900 1950 1950 2150 2200 2400 1750 1900 1900 1950 1950 2150 2200 2400 BH 1800 1800 1800 1850 1900 1900 2000 2000 1800 1800 1800 1850 1900 1900 2000 2000 1800 1800 1800 1850 1900 1900 2000 2000 Duplex AH 3650 3950 3950 4050 4050 4450 4550 4950 3650 3950 3950 4050 4050 4450 4550 4950 3650 3950 3950 4050 4050 4450 4550 4950 BH 1800 1800 1800 1850 1900 1900 2000 2000 1800 1800 1800 1850 1900 1900 2000 2000 1800 1800 1800 1850 1900 1900 2000 2000 R1 1480 1611 1678 1781 1834 2023 2197 2401 1480 1611 1678 1781 1834 2023 2197 2401 1480 1611 1678 1781 1834 2023 2197 2401 R2 2875 3134 3266 3529 3650 4032 4221 4617 2875 3134 3266 3529 3650 4032 4221 4617 2875 3134 3266 3529 3650 4032 4221 4617 R3 575 634 664 733 770 859 918 1012 575 634 634 733 770 859 918 1012 575 634 664 733 770 859 918 1012 R4 685 756 792 845 867 968

Wide Car

Deep Car

(Unit: mm) Pit Reaction Load(kg) R5 5298 5819 6085 6572 6805 7784 8269 9289 6091 6690 6996 7555 7823 8949 9507 10679 6350 6974 7293 7876 8155 9330 9911 11132 R6 4398 4719 4885 5172 5305 5984 6269 6989 5056 5425 5616 5946 6098 6880 7207 8034 5271 5656 5855 6199 6357 7172 7514 8376

Standard
Capacity Entrance Speed Opening Opening (m/s) Persons Load Type (mm) (kg) 6 8 9 1.0 10 11 13 15 17 6 8 9 1.5 10 11 13 15 17 6 8 9 1.75 10 11 13 15 17 450 550 600 680 750 900 1000 1150 450 550 600 680 750 900 1000 1150 450 550 600 680 750 900 1000 1150 2 Panel Side Opening 700 800 800 800 800 900 900 1000 700 800 800 800 800 900 900 1000 700 800 800 800 800 900 900 1000 Car Size Inside AN BN Outside AS BS Hoistway Size Top Beam Reaction Load(kg) Simplex AH 1700 1700 1700 1700 1800 1800 1850 1900 1700 1700 1700 1700 1800 1800 1850 1900 1700 1700 1700 1700 1800 1800 1850 1900 BH 1900 1900 1900 2050 2000 2200 2300 2450 1900 1900 1900 2050 2000 2200 2300 2450 1900 1900 1900 2050 2000 2200 2300 2450 Duplex AH 3550 3550 3550 3550 3750 3750 3850 3950 3550 3550 3550 3550 3750 3750 3850 3950 3550 3550 3550 3550 3750 3750 3850 3950 BH 1900 1900 1900 2050 2000 2200 2300 2450 1900 1900 1900 2050 2000 2200 2300 2450 1900 1900 1900 2050 2000 2200 2300 2450 R1 1593 1733 1802 1987 2020 2233 2429 2680 1593 1733 1802 1987 2020 2233 2429 2680 1593 1733 1802 1987 2020 2233 2429 2680 R2 2880 3137 3265 3440 3628 3987 4148 4464 2880 3137 3265 3440 3628 3987 4148 4464 2880 3137 3265 3440 3628 3987 4148 4464 R3 586 646 675 735 774 888 938 1035 586 646 675 735 774 888 938 1035 586 646 675 735 774 888 938 1035 R4 713 786 822 883 917 993 1062 1154 713 786 822 883 917 993 1062 1154 713 786 822 883 917 993 1062 1154

(Unit: mm) Pit Reaction Load(kg) R5 5455 5985 6248 6727 7022 8005 8481 9456 6271 6881 7183 7734 8072 9202 9749 10871 6538 7173 7489 8063 8415 9594 10164 11333 R6 4555 4885 5048 5327 5522 6205 6481 7156 5237 5616 5804 6125 6348 7133 7450 8227 5459 5855 6050 6385 6618 7436 7767 8576

1150 1080 1200 1262 1300 1100 1350 1282 1300 1180 1350 1362 1350 1280 1400 1462 1350 1350 1400 1532 1550 1350 1600 1532 1600 1450 1650 1632 1800 1450 1850 1632 1150 1080 1200 1262 1300 1100 1350 1282 1300 1180 1350 1362 1350 1280 1400 1462 1350 1350 1400 1532 1550 1350 1600 1532 1600 1450 1650 1632 1800 1450 1850 1632 1150 1080 1200 1262 1300 1100 1350 1282 1300 1180 1350 1362 1350 1280 1400 1462 1350 1350 1400 1532 1550 1350 1600 1532 1600 1450 1650 1632 1800 1450 1850 1632

1100 1130 1150 1331 1100 1300 1150 1501 1100 1380 1150 1581 1100 1550 1150 1751 1200 1520 1250 1721 1200 1770 1250 1971 1250 1850 1300 2051 1300 2010 1350 2211 1100 1130 1150 1331 1100 1300 1150 1501 1100 1380 1150 1581 1100 1550 1150 1751 1200 1520 1250 1721 1200 1770 1250 1971 1250 1850 1300 2051 1300 2010 1350 2211 1100 1130 1150 1331 1100 1300 1150 1501 1100 1380 1150 1581 1100 1550 1150 1751 1200 1520 1250 1721 1200 1770 1250 1971 1250 1850 1300 2051 1300 2010 1350 2211

1029 1135 685 756 792 845 867 968 1029 1135 685 756 792 845 867 968 1029 1135

EN Code
6 7 8 1.0 9 10 12 13 16 6 7 8 1.5 9 10 12 13 16 6 7 8 1.75 9 10 12 13 16 450 525 600 675 800 900 1000 1200 450 525 600 675 800 900 1000 1200 450 525 600 675 800 900 1000 1200 2 Panel Center Opening 700 800 800 800 800 900 900 1000 700 800 800 800 800 900 900 1000 700 800 800 800 800 900 900 1000 1150 1080 1200 1262 1300 1100 1350 1282 1300 1180 1350 1362 1350 1280 1400 1462 1350 1350 1400 1532 1550 1350 1600 1532 1600 1450 1650 1632 1800 1450 1850 1632 1150 1080 1200 1262 1300 1100 1350 1282 1300 1180 1350 1362 1350 1280 1400 1462 1350 1350 1400 1532 1550 1350 1600 1532 1600 1450 1650 1632 1800 1450 1850 1632 1150 1080 1200 1262 1300 1100 1350 1282 1300 1180 1350 1362 1350 1280 1400 1462 1350 1350 1400 1532 1550 1350 1600 1532 1600 1450 1650 1632 1800 1450 1850 1632 1750 1900 1900 1950 1950 2150 2200 2400 1750 1900 1900 1950 1950 2150 2200 2400 1750 1900 1900 1950 1950 2150 2200 2400 1800 1800 1800 1850 1900 1900 2000 2000 1800 1800 1800 1850 1900 1900 2000 2000 1800 1800 1800 1850 1900 1900 2000 2000 3650 3950 3950 4050 4050 4450 4550 4950 3650 3950 3950 4050 4050 4450 4550 4950 3650 3950 3950 4050 4050 4450 4550 4950 1800 1800 1800 1850 1900 1900 2000 2000 1800 1800 1800 1800 1850 1900 1900 2000 2000 1800 1800 1850 1900 1900 2000 2000 1480 1611 1678 1781 1834 2023 2197 2401 1480 1611 1678 1781 1834 2023 2197 2401 1480 1611 1678 1781 1834 2023 2197 2401 2875 3134 3266 3529 3650 4032 4221 4617 2875 3134 3266 3529 3650 4032 4221 4617 2875 3134 3266 3529 3650 4032 4221 4617 575 634 664 733 770 859 918 1012 575 634 634 733 770 859 918 1012 575 634 664 733 770 859 918 1012 685 756 792 845 867 968 1029 1135 685 756 792 845 867 968 1029 1135 685 756 792 845 867 968 1029 1135 5298 5819 6085 6572 6805 7784 8269 9289 6091 6690 6996 7555 7823 8949 9507 10679 6350 6974 7293 7876 8155 9330 9911 11132 4398 4719 4885 5172 5305 5984 6269 6989 5056 5425 5616 5946 6098 6880 7207 8034 5271 5656 5855 6199 6357 7172 7514 8376

EN Code
6 7 8 1.0 9 10 12 13 16 6 7 8 1.5 9 10 12 13 16 6 7 8 1.75 9 10 12 13 16 450 525 600 675 800 900 1000 1200 450 525 600 675 800 900 1000 1200 450 525 600 675 800 900 1000 1200 2 Panel Side Opening 700 800 800 800 800 900 900 1000 700 800 800 800 800 900 900 1000 700 800 800 800 800 900 900 1000 1100 1130 1150 1331 1100 1300 1150 1501 1100 1380 1150 1581 1100 1550 1150 1751 1200 1520 1250 1721 1200 1770 1250 1971 1250 1850 1300 2051 1300 2010 1350 2211 1100 1130 1150 1331 1100 1300 1150 1501 1100 1380 1150 1581 1100 1550 1150 1751 1200 1520 1250 1721 1200 1770 1250 1971 1250 1850 1300 2051 1300 2010 1350 2211 1100 1130 1150 1331 1100 1300 1150 1501 1100 1380 1150 1581 1100 1550 1150 1751 1200 1520 1250 1721 1200 1770 1250 1971 1250 1850 1300 2051 1300 2010 1350 2211 1700 1700 1700 1700 1800 1800 1850 1900 1700 1700 1700 1700 1800 1800 1850 1900 1700 1700 1700 1700 1800 1800 1850 1900 1900 1900 1900 2050 2000 2200 2300 2450 1900 1900 1900 2050 2000 2200 2300 2450 1900 1900 1900 2050 2000 2200 2300 2450 3550 3550 3550 3550 3750 3750 3850 3950 3550 3550 3550 3550 3750 3750 3850 3950 3550 3550 3550 3550 3750 3750 3850 3950 1900 1900 1900 2050 2000 2200 2300 2450 1900 1900 1900 2050 2000 2200 2300 2450 1900 1900 1900 2050 2000 2200 2300 2450 1593 1733 1802 1987 2020 2233 2429 2680 1593 1733 1802 1987 2020 2233 2429 2680 1593 1733 1802 1987 2020 2233 2429 2680 2880 3137 3265 3440 3628 3987 4148 4464 2880 3137 3265 3440 3628 3987 4148 4464 2880 3137 3265 3440 3628 3987 4148 4464 586 646 675 735 774 888 938 1035 586 646 675 735 774 888 938 1035 586 646 675 735 774 888 938 1035 713 786 822 883 917 993 1062 1154 713 786 822 883 917 993 1062 1154 713 786 822 883 917 993 1062 1154 5455 5985 6248 6727 7022 8005 8481 9456 6271 6881 7183 7734 8072 9202 9749 10871 6538 7173 7489 8063 8415 9594 10164 11333 4555 4885 5048 5327 5522 6205 6481 7156 5237 5616 5804 6125 6348 7133 7450 8227 5459 5855 6050 6385 6618 7436 7767 8576

24

Innovative SIGMA MRL Elevator

25

TECHNICAL DATA
Power Supply Plan
Entrance Details : Other floor
Narrow Jamb without Transom Panel

(Main Power : 380V) Capacity Speed (m/s) Persons 6 8 9 1.0 10 11 13 15 17 6 8 9 1.5 10 11 13 15 17 6 8 9 1.75 10 11 13 15 17 Load(kg) 450 550 600 680 750 900 1000 1150 450 550 600 680 750 900 1000 1150 450 550 600 680 750 900 1000 1150 Motor Capa. (kW) 3.7 3.7 3.7 4.6 4.6 6.2 6.2 7.0 6.5 6.5 6.5 8.1 8.1 11.0 11.0 12.5 6.5 6.5 6.5 8.1 8.1 11.0 11.0 12.5 MCCB Capacity of Building(A) Simplex 20 20 20 20 20 20 30 30 20 20 20 30 30 40 40 40 30 30 30 30 40 40 40 40 Duplex 30 30 30 30 40 40 50 50 30 40 40 50 50 60 60 75 50 50 50 50 60 75 75 100 Power Supply Capacity(kVA) Simplex 5.3 6.5 6.9 7.2 7.6 8.8 9.7 11.0 6.9 8.5 9.2 10.0 10.6 12.3 13.5 15.4 7.8 9.7 10.4 11.4 12.1 14.0 15.4 17.6 Duplex 10.6 12.9 13.9 14.4 15.2 17.7 19.4 22.0 13.8 17.1 18.4 20.0 21.3 24.6 27.1 30.8 15.7 19.3 20.9 22.8 24.2 28.0 30.9 35.2 Lead-in Wire Size( ) Simplex 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 10 6 6 6 6 6 6 10 10 Duplex 6 6 6 6 6 6 10 10 10 10 10 10 10 10 16 16 10 10 10 10 10 16 16 25 Earth Wire Size( ) Simplex 4 4 4 4 4 4 4 4 4 4 4 4 6 6 6 6 4 6 6 6 6 6 6 6 Duplex 6 6 6 6 6 6 6 6 6 6 6 6 6 6 10 6 6 6 6 6 6 10 10 10 Heat Output (kcal / H) 679 830 900 1020 1130 1350 1500 1725 1013 1240 1350 1530 1690 2030 2250 2588 1185 1450 1580 1790 1970 2370 2630 3025 Starting Power (kVA/set) 7.1 8.7 9.3 9.6 10.1 11.9 13.0 15.0 11.1 13.8 14.7 16.0 16.9 19.7 21.5 24.7 13.2 16.4 17.6 19.1 20.2 23.5 25.6 29.5

Section B-B

Section A-A

Front View of Entrance

The wire size should be calculated considering the voltage drop when travel exceeds 50m.

Building Structure Plan

Note
1. Hdimension in building structure plan depends upon the type of hall indicator selected. 2. Jdimension depends upon governing code requirement for height(above floor) of hall buttons. 3. Unit : mm

26

Innovative SIGMA MRL Elevator

27

TECHNICAL DATA
Entrance Details : Other floor
S-Type Wide Jamb with Transom Panel(with accentric line)

Entrance Details : Top floor


T-Type Wide Jamb with Transom Panel(with accentric line)

Section B-B

Section A-A

Section B-B

Section A-A

Front View of Entrance

Front View of Entrance

Building Structure Plan

Building Structure Plan

Note
1. Hdimension in building structure plan depends upon the type of hall indicator selected. 2. Jdimension depends upon governing code requirement for height(above floor) of hall buttons. 3. Unit : mm

Note
1. Hdimension in building structure plan depends upon the type of hall indicator selected. 2. Jdimension depends upon governing code requirement for height(above floor) of hall buttons. 3. Unit : mm

28

Innovative SIGMA MRL Elevator

29

TECHNICAL DATA
Technical Features
Standard Option

Work by Others
Description

Features
Attendant Operation Independent Operation Back-up operation

Safe Drive Operation

Safe Drive Operation Car Call Cancellation Automatic Turn-Off of Car Light & Fan Automatic Bypass Overload Holding Stop (110% of rated load) Detection of Jammed Hall Button Car Door Safety Edge Micro Levelling N-Plex Operation Non-Stop Operation Parking Operation VIP Operation Emergency Power Operation

Fire return operation Firemen Operation

Anti-nuisance Operation

Door Nudging Voice Synthesizer Door Photo Sensor

The operating mode of an elevator can be changed from the normal automatic operation to the attendant service by an attendant switch. Key switch in the car operating panel will cancel any existing car calls and hold the door open at the landing position. During independent operation, the car will respond only to car calls. When the electrical transmission device between the hall call and control panel begins to operate in an abnormal condition and it lasts for some time, the elevator control device is converted to back-up operation automatically. Then, the elevator moves in sequence up and down repeatedly from top to bottom floor to service every other floor which is in normal condition. When a car stops between floors due to mechanical malfunction, it will descend to the nearest floor at a low speed and hold the doors open after checking all safety measures. Allows cancellation of an incorrectly registered car call. For example, if you press the button for the wrong floor, you can cancel by pressing the same floor button again. Car illumination and fan are turned off automatically in case there is no hall call or car call; this saves energy. A fully-loaded car ( More than 80% of rated load) bypasses hall calls in order to maintain maximum operational efficiency. When the number of passengers exceeds the normal capacity, a buzzer sounds and the elevator remains stopped at that floor. When the excessive number of passengers disembark, the buzzer stops, the elevator doors close, and operation continues. If a hall button is jammed mechanically, the hall call will be automatically bypassed after being served once, until the program is resolved. Extending the full height of the car door, this device causes the doors to return to the fully open position should the door encounter a person or obstacle while closing. An automatic two way leveling device is provided to maintain the elevator car level with the landing, regardless of elevator load or direction of travel. It can control up to 4 sets of elevators to optimize allocation of hall calls. Specific floors which are memorized in control panel can be set to disable using switch on car operating panel or in security room. The elevator can be automatically parked at the predetermined floor with its doors closed, and the lights and ventilation will be turned off as well. The specified elevator is controlled by the special call buttons provided only for VIP elevator If normal building power supply fails and the building provides emergency power to the controller(s), one elevator at a time will proceed to the lowest landing where it will stop with doors open and with all of its power and operating circuits in an inoperative standby condition. In case of fire, a fireman can use the elevator which is stopped at the specified floor in order to support firemen for fire-fighting. In case of fire, a firemen can use the elevator which is stopped at the specified floor in order to support firemen for fire-fighting. In case of substantial difference between the number of calls registered on the car operating panel and actual load in the elevator, the elevator prevents unnecessary operation by cancelling all registered calls when it arrives at the nearest floor. When the doors remain open for more than the fixed door open time, this feature closes the doors at a reduced closing speed with the buzzer sounding. This system provides riding passengers with audio information about car operation such as direction of travel, landing floor, etc. The doors reverse to fully open position if the light ray unit detects an obstacle when the doors are closing.

The works below are not included in the elevator installation work and should be carried out by building contractors in accordance with our drawings, relevant international or local codes and regulations.

Hoist way

A properly framed and enclosed hoistway, including any ventilation as required by the governing code or authority. A dry pit constructed to the elevator manufacturer's specifications to reinforce or sustain any vertical forces on the guide rails and impacted loads from the car and counterweight buffers. A metal sill angle or concrete haunch across the full width of the hoistway at each elevator landing. Provision of steel bars to fix jamb around the entrance of each floor. All cutting, including cutouts to accommodate hall singal fixtures, patching, painting of walls, floors, or partitions, together with finish painting of entrance doors and frames, if required. Provision of entrance or ladder for pit access Supply and installation of fascia plate. Installation of emergency exits and electric wiring in blind sections of hoistway where required. The tolerance of perpendicular line over the whole hoistway height must not exceed 30mm. A waterproof outlet and light fixture in the elevator pit area with the light switch being located adjacent to the access door or ladder. Suitable light fixture and convenience outlet in the pit with a light switch adjacent to the access door or ladder. The receptacles shall have protection for ground fault circuit interrupter. Provision of wiring between controller and building management system. A construction hoisting beam or hook, if required, with the correct location and size as determined by the elevator contractor for each hoistway. Noise insulation should be installed between machine room and adjacent residential area.

Miscellaneous

Wiring and piping between monitoring system. Hoistway shall be free of dust or harmful gas. All electric power for lighting, tools, welding, etc during installation. All single phase receptacles installed in pit, and machinery spaces shall have ground fault circuit interrupter protection. Fire detector for fire emergency operation. A secured area for storage of elevator equipment and materials during installation.

30

Innovative SIGMA MRL Elevator

31