Está en la página 1de 12

Timers, counters, control and analogue interfaces

Zelio Time, Count, Control, Analogue

Confidence can be measured

Simply Smart!

Simply Smart!
Leveraging ingenuity and intelligence for ease of use

Zelio Time, Cou

Zelio

Time

Our complete and high-performance electronic timer conforms to international standards and corresponds exactly to your requirements. It is designed for all hard-wired logic automated systems complementing programmable logic controllers. Ergonomic and configurable Zelio timers are available in 3 versions: modular, industrial, panel-mounted.

Zelio

Count

XBK counters, when associated with sensing products, assure a complementary counting function within automation systems. A variety of simple functions, displays and settings are available in two technologies and three product families: XBKH: hour counting XBKT: totalizers XBKP: threshold preselectors

nt, Control and Analogue

Zelio

Control

Zelio Control covers all monitoring and control requirements. This range is in phase with industrial control systems, guaranteeing detection of breakdowns and faults. It enables three-phase network monitoring, AC and DC current and voltage measurement, and handles conducting liquid level control.

Zelio

Analogue

Zelio Analogue converters are designed to convert signals emitted by sensors or electrical measurements into standard electrical signals which are compatible with automation platforms and controllers (thermal processes and speed). They also increase the connection distance between a sensor and the measurement acquisition device (eg. between a thermocouple and a programmable controller).

Zelio Time
Modular Relays

RE11 range
The new timing relay offer presents a major size advantage with its width of 17.5 mm.

Compact dimensions only 17.5 mm wide. Single or multifunction ranges are available. Wide power supply range. Time range: 0.1 s to 100 h. Relay or solid-state output. Settings are protected by a sealable plastic cover. Simple to instal wiring and timing diagrams are located on side of relay.

17.5 mm

Spring terminals and settings are protected by a sealable plastic cover.

Wiring and timing diagrams are located on side of relay.

FUNCTIONS

POWER SUPPLY

TIME RANGE

OUTPUT

TERMINALS

CAT. NUMBERS

Timer on-delay Calibrator Pulse on energization Timer off-delay with control Asymmetrical flasher Multifunction (1) Multifunction (2) Multifunction (3) Timer on-delay Pulse on energization Timer off-delay with control Asymmetrical flasher Multifunction (2)

24 VDC & 24 to 240 VAC 24 VDC & 24 to 240 VAC 24 VDC & 24 to 240 VAC 24 VDC & 24 to 240 VAC 24 VDC & 24 to 240 VAC 12 VAC / DC 24 VDC & 24 to 240 VAC 12 to 240 VAC / DC 24 VDC & 24 to 240 VAC 12 to 240 VAC / DC 12 VAC / DC 24 VDC & 24 to 240 VAC 24 to 240 VAC/DC 24 to 240 VAC 24 to 240 VAC 24 to 240 VAC 24 to 240 VAC

0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 10 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h 0.1 s to 100 h

1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A 1 relay 8A static 0.7A static 0.7A static 0.7A static 0.7A static 0.7A

screw screw screw screw screw screw screw screw screw spring screw screw screw screw screw screw screw

RE11 RA MU RE11 RB MU RE11 RH MU RE11 RC MU RE11 RL MU RE11 RL JU RE11 RME MU RE11 RM MW RE11 RM MU RE11 RM MWS RE11 RM JU RE11 RMX MU RE11 LA MW RE11 LH BM RE11 LC BM RE11 LL BM RE11 LM BM

Multifunction (1) : Timer on-delay / Timer on-delay with time lock control / Calibrator / Timer off-delay with control / Pulse on energization / Pulse on energization with time control lock / Symmetrical flasher starting by pause or pulse. Multifunction (2) : Multifunction (1) and timer on-delay then timer off-delay by external control / Externally controlled differentiator. Multifunction (3) : Timer on-delay by external control / Single cycle flasher by control / Watchdog / Delayed watchdog / Delayed fixed pulse / Delayed fixed pulse with time lock control / Remote switch / Time delay remote switch / Timer off-delay when external control disappears.

Compact size/Accurate settings/Wiring and operating diagrams visible on product/UL, CSA and GL certified

Zelio Time
Industrial Relays

RE7 range
The 22.5 mm industrial range is perfectly suited to user requirements.

Standard dimensions: 22.5 mm W, 78 mm H, 80 mm D. Settings are protected by a sealable plastic cover. External control is possible for: v start of time delay v partial stop of time delay v adjustment of time delay Simple and quick installation. Wiring and timing diagrams are located on side of relay. Wide time range (up to 300 hours). Application adaptation (7 time delay choices). Two 8 A outputs (second output instantaneous or time delay). LEDs indicate time delay. Screw or spring connection. Wide voltage range (24 to 240 VAC/DC). Mounting on DIN rail or by screw without adapter plate. Compact size. UL, CSA and GL certified.

Settings are protected by a sealable plastic cover.

Wiring and timing diagrams are located on side of relay.

FUNCTIONS

POWER SUPPLY

TIME RANGE

OUTPUT

CAT. NUMBERS

Timer on-delay Timer on-delay and off-delay Control by external contact Timer off-delay on de-energization Timer off-delay control opening (low level) (low level) Pulse on energization Timer off-delay at on removal of external control Symmetrical flasher (off start) Asymmetrical flasher Star-delta starting time delay Star-delta starting time delay Multifunction (4) Multifunction (4) Star-delta starting time delay

24VAC/DC - 110 to 240 VAC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24 to 240 VAC / DC 24 to 240 VAC / DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to 48 VAC/DC 24VAC/DC - 110 to 240 VAC - 42 to48 VAC/DC 24VAC/DC - 110 to 240 VAC 24 to 240 VAC /DC

0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 10 m 0.05 s to 10 m 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h 0.05 s to 300 h

1 relay 8 A 1 relay 8 A 2 relay 8 A* 1 relay 8 A 2 relay 8 A* 1 relay 8 A 1 relay 5 A 2 relay 5 A* 1 relay 8 A 1 relay 8 A 2 relay 8 A* 1 relay 8 A 2 relay 8 A* 1 relay 8 A 2 relay 8 A* 1 relay 8 A 2 relay 8 A* 1 relay 8 A 2 relay 8 A 2 relay 8 A** 1 relay 8 A 2 relay 8 A* 2 relay 8 A*

RE7TL11BU RE7 TM11BU RE7 TP13 BU RE7 MA11BU RE7 MA13BU RE7 MV11BU RE7 RB11MW RE7 RB13MW RE7 RA11BU RE7 RM11BU RE7 RL13BU RE7 PE11BU RE7 PP13BU RE7 PM11BU RE7 PD13BU RE7 CL11BU RE7 CP13BU RE7 CV11BU RE7 YA12BU RE7 YR12BU RE7 ML11BU RE7 MY13BU RE7 MY13MW

Multifunction (4) : Timer on-delay / Timer off-delay / Pulse on energization / Pulse on opening control / Symmetrical flasher starts by pause or pulse. * 1 selectable in instantaneous ** with common point

Voltage markings on terminal blocks/Accurate Settings Wiring and operating diagrams visible on product/UL, CSA and GL certified

Zelio Time
Panel-mounted Relays

RE48 Range
The new range of plug-in timing relays in a 48 x 48 format is especially designed for integration in machines and equipment, for any application requiring frequent cycle time adjustment or setting.

Ergonomic design. Direct reading. Multifunction. Multivoltage: 24 to 240 VAC-DC. Wide time range: 0.02 to 300 h. Mounting spring supplied as standard. Connection sub-bases as option.

Readability: direct reading.

Wiring diagram located on relay side.

Flush-mounted.

Multifunction (5) : Timer on-delay / Pulse on energization


FUNCTIONS POWER SUPPLY TIME RANGE OUTPUT PINS SUB-BASES CAT. NUMBERS

Timer on-delay Asymmetrical flasher Multifunction (5) Multifunction (6)

24 to 240 VAC/DC 24 to 240 VAC/DC 24 to 240 VAC/DC 24 to 240 VAC/DC

0.02 s to 300 h 0.02 s to 300 h 0.02 s to 300 h 0.02 s to 300 h

2 relay 5 A 2 relay 5 A 2 relay 5 A* 2 relay 5 A

8 11 8 11

RUZ1D RUZ1A RUZ1D RUZ1A

RE48A TM12MW RE48A CV12MW RE48A MH13MW RE48A ML12MW

Multifunction (6) : Timer on-delay / Calibrator / Timer off-delay / Symmetrical flasher * 1 selectable to instantaneous mode

Easy to Configure/Accurate settings/Plug-in/UL, CSA and GL Certified

Zelio Count
Electronic and Electromechanical Counters

Electronic

Electromechanical

LCD or LED display and fast input counter ( 7.5 kHz). User-friendly display. Counting frequency. Configurable product (input type, mode, output). Internal battery. With or without reset to zero. Three sizes: 24 x 48 mm, 48 x 48 mm and 72 x 72 mm.

Mechanical display and slow input counter ( 25 kHz). Permanent display. Immunity against electrical and magnetic interference. Economical solution. With or without reset to zero. Two sizes: 24 x 48 mm and 48 x 48 mm.

XBKH Range hour counters*


Counts elapsed time in hours and 1/100 hours and displays / updates values.
DISPLAY POWER SUPPLY FREQUENCY RESET DIMENSIONS CAT. NUMBERS

Mechanical 7-digit LCD 8-digit

24 VAC 230 VAC Battery

50 Hz 50 Hz 1/100 h

without without manual*

48 x 48 mm 48 x 48 mm 48 x 24 mm

XBKH70000004M XBKH70000002M XBKH81000033E

XBKT Range totalizers*


Counts electrical pulses or contact and displays/updates value at each pulse; uni-directional.
DISPLAY POWER SUPPLY FREQUENCY RESET DIMENSIONS CAT. NUMBERS

5-digit Mechanical 6-digit 6-digit 8-digit LCD 8-digit

24 VDC 24 VDC 24 VDC 24 VDC Battery

20 Hz 10 Hz 25 Hz 25 Hz 7.5 kHz

manual without manual without manual*

41.5 x 31 mm 30 x 20 mm 60 x 50 mm 60 x 50 mm 48 x 24 mm

XBKT50000U10M XBKT60000U00M XBKT60000U10M XBKT80000U00M XBKT81030U33E

XBKP Range multifunction counters*


Upcounts or downcounts electrical pulses or contact. Displays and updates value and transmits an electrical signal when preselected threshold is reached.
DISPLAY POWER SUPPLY FREQUENCY RESET TYPE DIMENSIONS PRESELECTIONS CAT. NUMBERS

LCD 6-digit

LED 6-digit

24 VDC 115 VAC 230 VAC 24 VDC 115 VAC 230 VAC 24 VDC 230 VAC 24 VDC 230 VAC

5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz 5 kHz

manual, electrical, automatic manual, electrical, automatic manual, electrical, automatic manual, electrical, automatic manual, electrical, automatic manual, electrical, automatic manual, electrical, automatic manual, electrical, automatic manual, electrical, automatic manual, electrical, automatic

48 x 48 mm 48 x 48 mm 48 x 48 mm 48 x 48 mm 48 x 48 mm 48 x 48 mm 48 x 48 mm 48 x 48 mm 48 x 48 mm 48 x 48 mm

1 1 1 2 2 2 1 1 2 2

XBKP61130G30E XBKP61130G31E XBKP61130G32E XBKP61230G30E XBKP61230G31E XBKP61230G32E XBKP62130G30E XBKP62130G32E XBKP62230G30E XBKP62230G32E

* Not CSA certified. (For export only)

Simple/Rugged/UL listed

Zelio Control
Monitoring and Control Relays

RM4UA/B Voltage
measurement function

Under/overvoltage Adjustable timing 50 mV - 500 V

DC motor overspeed monitoring Battery monitoring

Network and power supply monitoring Speed monitoring

FUNCTIONS

RANGES

POWER SUPPLY

TIME RANGE

OUTPUT

CAT. NUMBERS

Undervoltage and overvoltage

Overvoltage

Overvoltage

<U : 80...120 VAC >U : 160...220 VAC <U : 160...220 VAC >U : 220...300 VAC 0.05 V... 0.5 V 0.3 V... 3 V 0.5 V... 5 V 1 V... 10 V 5 V... 50 V 10 V...100 V 30 V...300 V 50 V...500 V 0.05 V... 0.5 V 0.3 V...3 V 0.5 V...5 V 1 V... 10 V 5 V... 50 V 10 V...100 V 30 V...300 V 50 V...500V

Self-powered 100...200 VAC 0.1 to 10 s Self-powered 180...270 VAC 0.1 to 10 s 24 VAC 110...130 VAC 220...240 VAC 24 VAC 110...130 VAC 220...240 VAC 24 VAC 110...130 VAC 220...240 VAC 24...240 VAC/DC 110...130 VAC 220...240 VAC 380...415 VAC 24...240 VAC/DC 110...130 VAC 220...240 VAC 380...415 VAC 24...240 VAC/DC 110...130 VAC 220...240 VAC 380...415 VAC 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s

2 relay 8 A 2 relay 8 A 1 relay 8 A 1 relay 8 A 1 relay 8 A 1 relay 8 A 1 relay 8 A 1 relay 8 A 1 relay 8 A 1 relay 8 A 1 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A

RM4 UB34 RM4 UB35 RM4 UA01B RM4 UA01F RM4 UA01M RM4 UA02B RM4 UA02F RM4 UA02M RM4 UA03B RM4 UA03F RM4 UA03M RM4 UA31MW RM4 UA31F RM4 UA31M RM4 UA31Q RM4 UA32MW RM4 UA32F RM4 UA32M RM4 UA32Q RM4 UA33MW RM4 UA33F RM4 UA33M RM4 UA33Q

Overvoltage

Undervoltage or overvoltage

Undervoltage or overvoltage

Undervoltage or overvoltage

RM4J Current
measurement function

Under/overcurrent 3 mA - 15 A Adjustable timing

Measurement of current drawn by a 3-phase motor Heating and lighting circuit monitoring

Pump de-energizing monitoring Overtorque monitoring Mechanical brake and clutch monitoring

I
FUNCTIONS RANGES POWER SUPPLY TIME RANGE OUTPUT CAT. NUMBERS

Overcurrent

3 ... 30 mA 10 ... 100 mA 0.1... 1A 3 ... 30 mA 10 ... 100 mA 0.1... 1 A 0.3 ...1.5 A 1 ... 5 A 3 ...15 A

Over or undercurrent

Over or undercurrent

24 VAC 110 ... 130 VAC 220 ... 240 VAC 24... 240 VAC/DC 110 ... 130 VAC 220 ... 240 VAC 380 ... 415 VAC 24... 240 VAC/DC 110 ... 130 VAC 220 ... 240 VAC 380 ... 415 VAC

0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s 0.05 to 30 s

1 relay 8 A 1 relay 8 A 1 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A

RM4 JA01B RM4 JA01F RM4 JA01M RM4 JA31MW RM4 JA31F RM4 JA31M RM4 JA31Q RM4 JA32MW RM4 JA32F RM4 JA32M RM4 JA32Q

Simplicity/Performance/Compact Size/Safety/UL, CSA and GL Certified

Zelio Control
Monitoring and Control Relays

RM4T Network
monitoring function

Phase sequence Phase loss Unbalance Voltage measurement Adjustable timing 160 - 480 VAC

Connection of mobile equipment Protection of persons and equipment against reverse operation Sensitive networks

Protection against risk of a driving load (phase loss) Normal/emergency source switching

FUNCTIONS

RANGES

POWER SUPPLY

TIME RANGE

OUTPUT

CAT. NUMBERS

Phase loss and sequence Phase loss, sequence and undervoltage

Phase loss, sequence and undervoltage / overvoltage

Phase loss, sequence and voltage unbalance

220 - 440 VAC 160 - 220 VAC 300 - 430 VAC < 198 V (fixed) > 242 V (fixed) < 360 V (fixed) > 440 V (fixed) <U : 160...220 VAC >U : 220...300 VAC <U : 300...430 VAC >U : 420...480 VAC 5...15% 5...15% 5...15% 5...15%

Self-powered Self-powered 200...240 VAC Self-powered 380...440 VAC Self-powered 220 VAC Self-powered 400 VAC 0.1 to 10 s 0.1 to 10 s

2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 2 relay 8 A 1 relay 8 A 1 relay 8 A 2 relay 8 A 2 relay 8 A

RM4 TG20 RM4 TU01 RM4 TU02 RM4 TR33 RM4 TR34 RM4 TR31 RM4 TR32 RM4 TA01 RM4 TA02 RM4 TA31 RM4 TA32

Self-powered 220...240 VAC 0.1 to 10 s Self-powered 380...440 VAC 0.1 to 10 s Self-powered 200...240 VAC Self-powered 380...440 VAC Self-powered 220...240 VAC Self-powered 380...440 VAC 0.5 s fixed 0.5 s fixed 0.1 to 10 s 0.1 to 10 s

MPS and MPD relays (120 - 600 VAC)


FUNCTIONS RANGES POWER SUPPLY MOUNTING OUTPUT CAT. NUMBERS

Phase loss, Voltage unbalance, sequence, undervoltage Phase loss, Voltage unbalance, sequence, undervoltage

240V, 60Hz 480V, 60Hz 120V, 60Hz 240V, 60Hz 480V, 60Hz 600V, 60Hz

Self powered 240V, 60Hz Self powered 480V, 60Hz Self powered 120V, 60Hz Self powered 240V, 60Hz Self powered 480V, 60Hz Self powered 600V, 60Hz

Socket Mounted Surface Mounted

1 Relay, 5A 1 Relay, 5A 2 Relays 5A 2 Relays 5A 2 Relays 5A 2 Relays 5A

8430MPSV24 8430MPSV29 8430MPDV20 8430MPDV24 8430MPDV29 8430MPDV32

RM4LA/G Liquid
level function

0.25 - 500 K ohms Adjustable timing 24 - 240 VDC 25 - 415 VAC

Conduction liquid level regulation Protection of pumps and heaters against running dry

Overfill sensing Filling/emptying

FUNCTIONS

RANGES

POWER SUPPLY

TIME RANGE

OUTPUT

CAT. NUMBERS

Filling or emptying

5...100 K 0.25... 5 K 2.5... 50 K 25... 500 K -

Filling or emptying Suspended probe 1 electrode + 1 rf Protected suspended probe

24 VAC 110 ... 130 VAC 220 ... 240 VAC 24 ... 240 VAC/DC 110 ... 130 VAC 220 ... 240 VAC 380 ... 415 VAC by RM4 L.... by RM4 L....

0.1 to 10 s 0.1 to 10 s 0.1 to 10 s -

1 relay 8 A 1 relay 8 A 1 relay 8 A 2 relays 8 A 2 relays 8 A 2 relays 8 A 2 relays 8 A -

RM4 LG01B RM4 LG01F RM4 LG01M RM4 LA32MW RM4 LA32F RM4 LA32M RM4 LA32Q LA9 RM201 RM79 696 043

Simplicity/Performance/Compact Size/Safety/UL, CSA and GL Certified

Zelio Analogue
Analogue Interfaces

Zelio Analogue Converter and Transmitter

Pre-calibration of input and output ranges facilitate installation. High repeatability of output signals as a function of input signal. Outputs protected against polarity inversion, short-circuit and overvoltage. Loop breakdown protection. Sealable protective cover. Conforms to UL/CSA/GL/EC standards. DIN rail or screw mounted.

IP1

2-Wire

PT100

IP2 IP3 IP4 2mA 19..30VDC IP1 IP1 IP2 IP3 IP4 A2 IP1 0VDC OPG A1 V0

RMPT Converters for PT 100 probes

3-Wire

PT100

IP2 IP3 IP4

4-Wire

PT100

IP2 IP3 IP4

Converts the ohmic resistance 2, 3 or 4 wire PT 100 probes to standard. A preset temperature range for the inputs depending on the model. Switchable output of 0 - 10V, 0 - 20mA and 4 - 20mA. Optimum Pt100 converters have an output of 0-10V only.

Universal
PT 100

INPUT / SCALE (Temp. Range)

OUTPUT (Output Range)

DIMENSIONS (H/W/D - mm)

POWER SUPPLY (Voltage)

CAT. NUMBERS

-4040C -40104F -100100C -148212F 0100C 32212F 0250C 32482F 0500C 32932F

010 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable

22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80

24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated

RMPT10BD RMPT20BD RMPT30BD RMPT50BD RMPT70BD

Optimum
PT 100

INPUT / SCALE (Temp. Range)

OUTPUT (Output Range)

DIMENSIONS (H/W/D - mm)

POWER SUPPLY (Voltage)

CAT. NUMBERS

-4040C -40104F -100100C -148212F 0100C 32212F 0250C 32482F 0500C 32932F

010 V 010 V 010 V 010 V 010 V

22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80

24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated

RMPT13BD RMPT23BD RMPT33BD RMPT53BD RMPT73BD

10

Compact/Simple/Choice of outputs/UL, CSA and GL certified

Zelio Analogue
Analogue Interfaces

RMT Converters for J & K type thermocouple


19..30VDC Type K A1 IP1 (+) IP2 (-) A2 0VDC V0

OPG

Converts the voltage signal from J & K type thermocouple to standard signals. These converters have cold junction compensation to allow detection of errors induced by connection to the device itself. The converters have a preset temperature range for the inputs depending on the model and a switchable output of 0 - 10 V, 0 - 20 mA and 4 - 20 mA.

INPUT / SCALE (Temp. Range)

OUTPUT (Output Range)

DIMENSIONS (H/W/D - mm)

POWER SUPPLY (Voltage)

CAT. NUMBERS

0150C 32302F 0300C 32572F 0600C 321112F 0600C 321112F 01200C 322192F

010 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable

22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80

24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated

RMTJ40BD RMTJ60BD RMTJ80BD RMTK80BD RMTK90BD

RMC voltage/current converters

4..20mA

19..30VDC A1 I1 IPG A2 0VDC

V0 OPG

Allows adaptation of electrical values (voltage/current). Four products are available: a cost effective converter will convert 0...10 V signal to a 4...20 mA signal or vice-versa; a universal voltage/current converter converts the most common signals; and two universal voltage/current converters for the conversion of AC as well as DC power signals.

0..10V

19..30VDC A1 V1 IPG A2

I0 OPG

19..30VDC A1 A2 0VDC V1 V2 V3 IPG V0

0VDC

19..30VDC OPG A1 A2 0VDC I1 I2 I3 V0 I01 I02

INPUT / SCALE

OUTPUT (Output Range)

DIMENSIONS (H/W/D - mm)

POWER SUPPLY (Voltage)

CAT. NUMBERS

010 V or 420mA 010 V / 020 mA / 420 mA 050 V / 0300 V / 0500 V 01.5 A / 05 A / 015 A

010 V or 420 mA 010 V / -10+10 V / 020 mA / 420 mA Switchable 010 V / 020 mA / 420 mA Switchable 010 V or 020 mA or 420 mA

22.5 / 80 / 80 22.5 / 80 / 80 22.5 / 80 / 80 45 / 80 / 80

24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated 24 V DC Non Isolated

RMCN22BD RMCL55BD RMCV60BD RMCA61BD

19..30VDC A1 A2 0VDC V1 I V V0 I1 IPG OPG

Compact/Accurate/Universal/UL, CSA and GL certified

11

Simply Smart!
The efficiency of Telemecanique branded solutions
Used in combination, Telemecanique products provide quality solutions, meeting all your automation and control applications requirements.

Operator dialog

Software tools Motion control

Networks & Communication

Interfaces & I/O

Automation

Motor control

Detection Mounting systems

Power supplies

unique partner and a worldwide presence

Worldwide availability More than 5,000 points of sale in 130 countries. You can be sure to find a range of products that meets your needs and fully complies with the standards in the country in which they are used. Schneider Electrics regional focus 200 dedicated sales engineers operate from 22 regional sales centres and 13 technical service centres across Canada. Our sales engineers are skilled at assessing individual requirements. Combined with the expert support of our product specialists, they will develop the most effective and economical solution for you, taking relevant regulations and standards into account.

Schneider Electric Head Office 19 Waterman Avenue Toronto, Ontario M4B 1Y2 www.schneider-electric.ca Tel: (416) 752-8020 Fax: (416) 752-8944 Customer Service: 1-800-565-6699
T9050BR0501EP R0 July 2005

2005 Schneider Canada Inc., All Rights Reserved