Está en la página 1de 27

Power Transmission and Distribution

SIPROTEC

Power Transmission and Distribution

Rels de Proteccin: mas de 90 aos de experiencia!!


No. 1 with Energy Automation

Rels Electro Mecnicos


1910

SIPROTEC 4 es la 4ta generacin de rels numricos!

1985 1970

Rels numricos

Rels analgicos estticos

Energy Automation Buenos Aires Nov 05

Page 2

Power Transmission and Distribution

Referencias de protecciones numricas 409.000 rels en servicio!


No. 1 with Energy Automation

Rels entregados hasta setiembre 2004


n n n n n n n

Proteccin de sobrecorriente 7SJ5, 7SJ6 Rel de frecuencia 7RW600 Proteccin de distancia 7SA5, 7SA6 Proteccin diferencial de trafo/generador. 7UT5/6 Proteccin diferencial de lnea 7SD5, 7SD6 Proteccin de mquinas 7UM5, 7UM6, 7VE5

276.900 9.300 61.100 28.400 22.400 9.900

Sistemas de proteccin de barras 1.870 7SS5, 7SS52, 7SS60 Total 409.670


Page 3

Energy Automation Buenos Aires Nov 05

Power Transmission and Distribution

Power Automation Aplicacin


No. 1 with Energy Automation

Energy Automation Buenos Aires Nov 05

Page 4

Power Transmission and Distribution

Caractersticas: Protecciones SIPROTEC


No. 1 with Energy Automation

Tecnologa avanzada , adecuada para aplicaciones dentro de instalaciones de media y alta tensin Rels Numricos para todas las aplicaciones de proteccin SIPROTEC 4
Software Estandarizado de operacin para el rango completo de productos

Energy Automation Buenos Aires Nov 05

Page 5

Power Transmission and Distribution

Caractersticas: DIGSI 4 ajuste y anlisis


No. 1 with Energy Automation

Configuracin, ajuste puesta en servicio y anlisis de fallas

Energy Automation Buenos Aires Nov 05

Page 6

Power Transmission and Distribution

Protecciones Numricas SIPROTEC Rango Actual


No. 1 with Energy Automation

SIPROTEC easy

SIPROTEC Compact Class

SIPROTEC 4 (equipos de control y

proteccin)

Energy Automation Buenos Aires Nov 05

Page 7

Power Transmission and Distribution

Rel de Proteccin SIPROTEC easy Alcance de Productos


No. 1 with Energy Automation

7SJ45 Proteccin de sobrecorriente - tiempo Alimentado por CT - no se necesita energa auxiliar n 7SJ46 Proteccin de sobrecorriente - tiempo Alimentado por fuente auxiliar

Energy Automation Buenos Aires Nov 05

Page 8

Power Transmission and Distribution

Rel de Proteccin SIPROTEC Compact Class: Alcance de Productos


No. 1 with Energy Automation

n n n n n

7SJ600 7SJ601 7SJ602

Sobrecorriente / Sobrecarga, 3 CTs Sobrecorriente (func. reducida) Sobrecorriente / Sobrecarga, 4 CTs

7RW600 Sobre-Subtensin / Frecuencia 7SD600 Proteccin Diferencial de lnea por hilo piloto 7SV600 7SS60 7VH60 Proteccin de falla de interruptor Proteccin diferencial de barras Proteccin dif. De alta impedancia

n n n n

7SN600 Rel de falla a tierra transitoria

Energy Automation Buenos Aires Nov 05

Page 9

Power Transmission and Distribution

Proteccin SIPROTEC 3/4 7SS52: Proteccin de Baja impedancia de barras y falla de interruptor
No. 1 with Energy Automation

SIPROTEC 4
n

Proteccin de barras (Fase Segregada) Checkeo de zona Integrado Proteccin falla de interruptor Replica de seccionadores Medicin de valores Una Bay Unit por Alimentador Proteccin de sobrecorriente y tierra de respaldo Entradas y salidas para Interruptor y seccionadores Conexiones a los CTs Medicin de valores
Page 10

n n n n n n

SIPROTEC 3

n n
Energy Automation Buenos Aires Nov 05

Power Transmission and Distribution

Rels de Proteccin y Control SIPROTEC 4 Alcance de Productos


No. 1 with Energy Automation

7SJ61 Proteccin de sobrecorriente y tierra 7SJ62 Proteccin Direccional de sobrec. y tierra 7SJ63 como 7SJ62 con display largo 7SJ64 como 7SJ63 con verificador de sincro. 7SA52 Proteccin de distancia, 4 puertos de com. 7SA6 Proteccin de distancia, opcional display 7SD52 Proteccin dif. de lnea; hasta 6 terminales 7SD61 Proteccin dif. de lnea; 2 terminales 7UM61 Proteccin de Generador/ Motor 7UM62 como 7UM61 con Proteccin Diferencial 7UT61 Proteccin dif.de mquina/objeto de 2 a 5 extremos 7VK61 Equipo de recierre PFI y sincrocheck

Energy Automation Buenos Aires Nov 05

Page 11

Power Transmission and Distribution

SIPROTEC 4 Interface Hombre - Mquina


No. 1 with Energy Automation

LED de funcionamiento y error Display Iluminado Teclas de cursor


LEDs con tecla de reset Teclas de Control Llaves de Control

Interface Local Teclas de Funcin Teclado numrico

Energy Automation Buenos Aires Nov 05

Page 12

Power Transmission and Distribution

SIPROTEC 4 - Highlights
No. 1 with Energy Automation

Log. IN 1

F1 >1
Log. IN 2 Log.OUT1

F2

Funcionalidad lgica completa

Log.IN3

CFC
Salidas Lgicas a la matriz

Entradas Lgicas desde la matriz a CFC

Lgica adicional n Interlocking n Proceso de valores medidos

Energy Automation Buenos Aires Nov 05

Page 13

Power Transmission and Distribution

SIPROTEC 4 - Highlights
No. 1 with Energy Automation

I1 :400.9A U1:12.22kV P :+8.03MW Q :+2.64MVar

f:50.0Hz cos? :0.95?

Procesamiento integral de valores medidos

L1 L2 L3 E

402.1A 401.2A 401.0A 00.0A

Max450.1A Max421.2A Max431.4A

% IL L1 100.0 L2 100.4 L3 100.1

UL-E 100.4 100.3 100.1

UL-L 100.1 100.0 100.4

Energy Automation Buenos Aires Nov 05

Page 14

Power Transmission and Distribution

SIPROTEC 4 - Highlights
No. 1 with Energy Automation

Conexin directa al campo

Energy Automation Buenos Aires Nov 05

Page 15

Power Transmission and Distribution

SIPROTEC 4 - Highlights
No. 1 with Energy Automation

Terminales Robustos

Energy Automation Buenos Aires Nov 05

Page 16

Power Transmission and Distribution

SIPROTEC 4 - Highlights
No. 1 with Energy Automation

Interfaces de comunicacin Flexibles

ptica

elctrica
n n

intercambiable expandible

Energy Automation Buenos Aires Nov 05

Page 17

Power Transmission and Distribution

SIPROTEC 4 - Highlights
No. 1 with Energy Automation

Fcil manejo con DIGSI 4

Energy Automation Buenos Aires Nov 05

Page 18

Power Transmission and Distribution

SIPROTEC 4 - Highlights
No. 1 with Energy Automation

Display mmico configurable

Energy Automation Buenos Aires Nov 05

Page 19

Power Transmission and Distribution

SIPROTEC 4 - Highlights Plataforma Flexible


No. 1 with Energy Automation

Proteccin

Control, men guiado Display de 4-lneas


Proteccin

Control, va diagrama mmico Display grafico


Proteccin

Control, va diagrama mmico Display grafico Unidad HMI Detachable

Cajas disponibles para montaje superficial o embutido

Energy Automation Buenos Aires Nov 05

Page 20

Power Transmission and Distribution

Portfolio, Protecciones de Sobrecorriente


No. 1 with Energy Automation

Funcionalidad
HMI Detachable Diagrama Unifilar Control Local Funciones de Control para Interruptores, seccionadores Entradas de Transductor 20mA Proteccin Multifuncional Funciones Lgicas Display de Texto de 4x20 PLC; Control Interruptor 7SJ61 7SJ602 7SJ600 7SJ601 Limitado I/O Limitado I/O 7SJ63/64 6MD63 7SJ62

7SJ63/64 6MD63

Control Limitado Proteccin Multifuncional No Control Local solo Proteccin de Sobrecorriente

I/O
Mximo I/O Mximo I/O

Energy Automation Buenos Aires Nov 05

Page 21

Power Transmission and Distribution

7SJ64 Alcance de Funciones


No. 1 with Energy Automation

52

Local-Remote-Control Command/Feedback
Trip circuit supervision

RTD box Interface

Tensin
f<> V> V<

25
Lock out

Direccional 27
Phase rotation

PLC-Logic
&

falla Locator 21FL

81O/U

59

Motor control

33

74TC

86

47 Meter

HMI

Comunicacinmodules RS232/485 Fiber

falla Recording

U, P, Q, f, cos ? calculated

I, Set points
Breaker-failure Protecci n

IEC60870-5-103 Profibus FMS

20 Flexible protection functions


I2>

Energy meter impulse Motor Proteccin I< Start up monitor 37 14 48


locked Rotor

I>>

I>, Ip

IE>>

IE>, IEp

> 46 49
Inrushblocking

50
IE>>

51
IE>, IEp

50N

51N

50BF

66/86

67

67N

Lock out

50N

51N

Auto reclosing

IEE>> IEE>

UE>

79M

S67N

S64

Dirct. sens . Ground falla

Energy Automation Buenos Aires Nov 05

Page 22

Power Transmission and Distribution

7SJ61/62/63/64 con RTD box(es) 7XV5662 Para supervisin de Sobrecarga/Temperatura


No. 1 with Energy Automation

FO - conexin a interface servicio OR RS485 conexin a interface servicio

O RS485

n conexin

de hasta 2 equipos RTD a la interface de servicio (FO o bus RS485) n Monitoreo de hasta 12 puntos de medicin (6 por RTD) Dos Umbrales son programables con DIGSI (como Entradas al editor de Lgica)
Energy Automation Buenos Aires Nov 05 Page 23

Power Transmission and Distribution

7UT6xx - versiones de Hardware


No. 1 with Energy Automation

h7UT612 p/ proteccin de objetos de 2 extremos


h 7 x I (1A, 5A, 0,1A), 1 x Iee h 3 entradas y 4 salidas binarias, 1 contacto eq. sano

h7UT613 p/ proteccin de objetos de 3 extremos


h 11 x I (1A, 5A), 1 x Iee h 5 entradas, 7 salidas binarias, 1 contacto eq. sano

h7UT633 p/ proteccin de objetos de 3 extremos


h 11 x I (1A, 5A), 1 x Iee, 3 x Uph, 1 x Ue h 21 entradas, 23 salidas binarias, 1 contacto eq. sano

h7UT635 p/ proteccin de objetos de 5 extremos


h 16 x I (1A, 5A, 0,1A), 1 x Iee, 3 x Uph, 1 x Ue h 21 entradas, 15 salidas binarias, 1 contacto eq. sano

Energy Automation Buenos Aires Nov 05

Page 24

Power Transmission and Distribution

Ejemplos de Aplicacin para configuracin orientada por objetos


No. 1 with Energy Automation

GS 3~
7UT612 7UT612

transformador de 2 Arrollamientos 1 o 3 fases Auto transformadores

proteccin diferencial de Generador/Motor Barra: 7 Alimentadores con 1 equipo por fase

7UT612

Lineas Cortas con 2 extremos (~500m)

7 Alimentadores con transf. sumadores 1 equipo


7UT612

Energy Automation Buenos Aires Nov 05

Page 25

Power Transmission and Distribution

Commissioning aids with Browser


No. 1 with Energy Automation

Energy Automation Buenos Aires Nov 05

Page 26

Power Transmission and Distribution

Commissioning aids with Browser


No. 1 with Energy Automation

Energy Automation Buenos Aires Nov 05

Page 27

También podría gustarte