Está en la página 1de 11

1.

a) b) c) d) 2. a) b) c) d) 3. a) b) c) d) 4. a) b) c) d) 5. a) b) c) d) 6. a) b) c)

1` 2 1` telemetering signal conditioning c g

2-[--ppiuiiiiuUse of remote indicators is for

13. a) b) c) d) 14.

which of the following equations is true Pabs=Pgauge+Patm Pabs=Pgauge-Patm Pabs=Pgauge*Patm Pabs=Pgauge/Patm\ displacer type level measuring instruments work on the principle of a) archimedes principle b)Bernoullis principle c) newtons third law d) stokes law the relation between flow and differential pressure(dp) is f=k* sqrt(t/dp) f=1/k * sqrt(dp/t) f= k* sqrt(dp/t) none of the above filled system thermometers are used for local indication remote indication both a and b none of the above platinum rtd is calibratedto have . Ohm and ohm at 0 degree C 42 and 50 56 and 480 46 and 530 None of the above the throttling device used for creating dp for flow measurement is orifice venture flow nozzle all of the above 1 technical atmosphere pressure is equal to 760 mm Hg 750 mm Hg 738.5 mm Hg None of the above

Which of the following instruments is a calibrating pressure measuring instruments bourdon gauge manometer diaphragm bellows Accurate temperature measurement is needed for material fatigue heat balance heat transfer all of the above The instrument most commonly used for vaccum measurement is diaphragm bellows kenotometer none of the above To protect pressure measuring instruments from violent pressure surges and pulsations,we use snubber dummy gauge orifice Nozzle Pigtail siphon is used in horizontal pipe vertical pipe both of the above

15. a) b) c) d) 16. a) b) c) d) 17. a) b) c) d) 18. a) b) c) d) 19. a) b) c) d)

7. u type siphon is used in a) horizontal pipe b) vertical pipe c) both of the above 8. a) b) c) d) 9. a) b) c) d) 10. a) b) c) d) 11. a) b) c) d) 12. a) b) c) d) The output of thermocouple is in mv ma ohm none of the above which of the following is a primary measuring instrument for temperature electronic bridge rtd temperature gauge all of the above k type thermocouple is iron-constantan copper constantan chromel alumel chromel copel which of the following materials is not used for rtd ni pt cu al cold junction compensation is used in thermocouple rtd thermistor bimetallic strip

20. gauge pressure is measured relative to a) perfect vaccum b) ambient pressure c) differential pressure d) none of the above 21.thermocouple works on the principle of a) seedown effect b) seeright effect c) seebeck effect d) none of the above 22.which thermocouple is used most commonly in thermal power plant? a) s type b) r type c) k type d) b type 23. rtd is a) active transducer b) passive transducer c) both a and b d) none of the above 24. which of the following is not a type of sight glass a) tubular glass b) flat glass c) convex glass d) magnetic gauge 25. LVM stands for a) Limit Value Monitor

b) Large Value Monitor c) Low Value Monitor d) Local Value Monitor 26. radioactive method is used to measure a) mass of coal b) flow of coal c)level of coal d) density of coal 27. level measurement is generally carried out as a) horizontal level b) differential pressure c) vertical pressure d) none of the above 28. .. is used for preventing live steam from entering and damaging the device a) snubber b) siphon c) both d) none 29. the pigtail siphon is used on .. pipelines where there is sufficient space above the pipes a) horizontal b) vertical c) diagonal d) linked 30. condensate pressure is measured after the condensate pump and before the a) hp heater b) lp heater c) ejector d) deareater 31. the balance between induced and forced draught fans is produced by measuring and controlling the a) furnace suction b) discharged flue gas c) steam flow d) furnace dimension 32. bourdon tube gauges are used in the ange a) 0.05ksc to 6000ksc b) 1ksc to 6000 ksc c) 100 ksc to 10000 ksc d) none of the above 33. which type of compensation is used in thermocouple a) cold junction compensation b) hot junction compensation c) lag compensation d) lead compensation 34. on which TSI parameter, a turbine trip is executed? a) axial shift b) vibration c) differential expansion d) eccentricity 35 state whether true or false 1. manometers using water, mercury and other liquids of known densities is used for low pressure measurement. 2. Bourdon tube gauge is used for low pressure measurement 3. Rtd and thermocouple are used for local indication of temperature 4. Main steam temperature, pressure, condenser vacuum, drum level, furnace pressure etc are presented through single point indication/recorder 5. Standardised output range is 10-20mA 6. Hydrastep works on conductivity measurement 7. Transmitter can be used for generating alarms 8. Thermistor shows negative temperature co-efficient 9. Relay valve is used to improve the flapper and nozzle assembly. 10. Dead weight pressure gauge tester is used to measure pressure

1.The guage factor is defined as a)( L/L)/( R/R) b)( R/R)/( L/L) c)( R/R)/( D/D) d)( R/R)/( / ) 2.what is the order of minimum displacement that can be measured with capacitive transducers? a)1 cm b)1mm c)1 m d)1nm 3.The order of sensitivity in higher to lower order is a)thermistor,RTD,Thermocouple b)RTD,thermistor,Thermocouple c)Thermocouple,RTD,thermistor d)RTD,Thermocouple,thermistor 4.Hydrastap is used for measurement of a)feed water flow b)drum level c)heater level d)hydrogen purity 5. Number of faceia in an annunciation window is a)23 b)32 c)45 d)12 6.Total no.of annunciation window in UCB are a)4 b)6 c)12 d)15 7.When ACKNOWLEDGE push button is pressed in case of any alarm a)lamp off &hooter on b)lamp steadyflash & hooter off c)lamp fastflash & hooter off d) lamp fastflash & hooter on 8.The method of placing the instrument at a distance from the measuring point is a)telemetring b)telecommunication c)teleconferencing d)annunciation 9.Accuracy is highest in case of a)RTD b)Themocouple c)Thermistor d)sensistor 10.Pressure loss is maximum in case of a)venturi b)orifice c)nozzle d)pitot tube 11.Resistance thermometers are of _______ &________ type a)pt-cu b)al-ag c)au-ag d)fe-mg 12.which of the parameter is not included in case of TSI___ a)differential expansion b)turbine speed c)shaft eccentricity d)casing temperature

13.Flappernozzle assembly converts a)pneumatic signal to mechanical movement b)mechanical movement to pneumatic signal c)electrical signal to pneumatic signal d)electrical signal to mechanical signal 14.Nozzle orifice is _______ larger than restrictor orifice a) 4 times b) 6 times c) 3 times d) 2 times 15.Sesimic sensor is also known as a)displacement sensor b)velocity sensor c)acceleration sensor d)force indicator ;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;;; 1. Indicate which of the following is true a)Absolute pressure =Gauge pressure and atmospheric b) Absolute pressure = Gauge pressure =atmospheric a) Absolute pressure&Gauge pressure = atmospheric pressure b) None of the above 2. A compound gauge can measure a) pressuro only b) vacuum only c) both A&B d) None of above 3. Diaphragm type pressuro gauge is used for a) Flow measurement b) Water pressure measurement c) Pressure measurement in viscose medium d) All the above 4. Pressure gauge can be used to measure level in a) closed vaossel b) open vossel c) (a) & )b) 5. Inclined manometor is used to measure a) very high pressure b) vefry low pressure c) medium pressure d) any range of pressure 6. the following erros may occur in a linkage typc C bourdon tubo pressure gauge a) zero orror and rang error b) zero orror and linearity error c) zero orror and span orror d) all the above 7. The rosistance of prt 100 ohms is 100 ohms at a) 1oo0c b) o0c c) Room temperature d) 3o0c 8. three wire system is used with ordor in order to a) compensates for tomporature variations b) compensate for chango in lead resistence due to ambient tomperature c) compensate for millivolts error d) componsate for load resistance 2. Lowest value at Kelvin scale can be measured is a) o0c b) 100oc C)2730oc d) 5460c 3. coc is used in measuring instruments and recorders for a) RTD moasurement b) Millivolts signal c) thermo couples signals d) temperature transducers 11. Main principle of work in of thermocouples is a) Thomson effect b) seback effect

c) peltior effect d) intermediate metal effect 12.Compensating cable is used with a) RTDS b) Chromel alumel thermocouples c) Chromel capel thermocouples d) All type of thermo- couples 13.Relatien between Celsius .Farenhite and reyumer scale of temperature measurement is a) C / 100 = F=32 /180 = R 3 / 80 b) C / 5 = f 32 /18 = R /4 c) C / 10 = F 32 / 18 = r /8 d) C /80 = f 32 / 100 = r 180 14. The rate of flow through a rostriction and the differontial pressure of governed by the equation a) Q varies proportionally with D. P. b) c) Q varies proportionally with D.P. Q varies proportionally with D.P. d) None of the above 15. In a glass tube rotamoter. For any given flow, the diferontial pressure across the float a) Just equal to the weight of the float b) Allways more than the woihgt of the float c) Allways more than the weight of the float d) None of the above 16. The rate of flow in open channol is moasuro be means of a) Wiers b) Flumes c) Both (a) & (B) d) None of the above 17.difforontial pressure across en orifico plate for doubling the flow rate will be a) two times the original value b) three times the original value c) four times the original value d) eight times the original value 18.Magnotic flow motor are used to measure a) Velocity of fluid b) Volume of fluid c) Mass of fluid d) All the above 19.The hydrastep drum level measurement system works on the principle of a) Measurement of conductivity of Wator b) Measurement of conductivity of Water c) Measurement of resistivity of steam & water d) None of the above 20.In D. P. type drum level measurement of level is a) Directly proportional to the D.P. b) Inversely proportional to the D.P. c) Egual to the D. P. d) None of the above 21. Three shapes of a bourdon tube are -----------------------------------------------22. the most commen substance used to capsule diaphragm is -----23. the motal used in bourdon tube should not undergo a) fatiguc b) hysterisis c) croop d) all of the above. 24. The rotameter is a ------------- type flow measuring instrument 25. As the rotameter float rises in the tube the areas available for flow (in craso / decrease) 26.The fluid measured by a rotameter flow from the a) top to bottom b) mid point to top

c) bottom to the top d) mid point to the bottom 27. turbine and magnetic flow meters are ( volume tric/mass) flow moasuring device 28. The rotor of a turbine flow meter spins at a rate proportional The ------------ of the fluid flowing through the meter 29. Submerged displacers are not much affected by rapid change In liquid level TRUE / FAL 30..Hydrastep is superior than other method for drum love Moasurement as a) Smallefr orror incurred due to Chango in liquid densities b) steam and water level separating is easily detectable c) maintenance is less and more reliable d) all of the above __________________________________________________1. Name the different sbapes of bourdon pressur gauge -----------------------------------------------------------------2. ILK trans IE pressure tramsmitters work on ---------------------------------------------------------------------------------3. Rosemount transmitter uses a) two wire system b) four wire system c) six wire system d) none of the above 4. Deadweight testers are used to test & calibrate a) pressure gauges and switches b) dead wts on the testers c) comparing standard pressure gauge and gauge undefr test for very low ranges d) dead accurate wt. Lifters 5. for adjusting of span in c Bourdan tubepressure gauge is a) Link screw connecting the Bourdon tube at The end b) At the screw connecting the link to the cuadrant elongated slot b) By increasing the tension in the hair sprinty c) By pointer shifting 6. for increase indeflection with same pressure in diabhragm gauges with same metal a) Thickness of the material is to be reduced b) Area of diaphragm is to be increased c) No of corrugations are to be increased d) All the above 7. Atmospheric pressure at a point on earthlike liquid pressure is caused by the a) Tempr. Of the air surrounding the earth. b) Densityof the air surrounding earth c) Volume of air at certain pressure at that point d) Weight of the air surrounding the earth at that ooint. 8. Liquid filled in manometer used for hich pressure measurement is a) Alcohol b) Silicon oil c) Water d) Mercury 9.when gaugepressr. Reads . reads 0250 atm .The absolut absolute pressure is a) 1. 01-atm b) 0.750 atm c) 0.510 atm d) 0.750atm 10.Name five pressure measuring elements a) Bowrdon tube b) Diaplragm c) Bellow d) Flappr Nozzb/ monometer. PPiezoelut ric orystal 11.Inclined tube manomefter is used to measure a) high pressure very accurately b) Low dressure very accurately c) High viscosity fluids d) Volatile liquids 12.Unit of measurement only usable for vaccum a) Torr

b) Mmhg c) Mm wel d) Kg/cm2 13.Pressure measued by water filling Utube manomever 1360 mmwcl what will be measured Value if we replace water by mercury/ a) 136mmHg b) 100 c) 23.6mmHg d) 360mHg 14. When there is open circuit in RTD element the indjcator should read a) Zero b) Normal c) Maximum d) mid scale 15. tempr. Recorder reading 350oc Ambient tempr is 30 oc what will be thefrmocouplw m. c. equivalent tempr? a) 5200c b) 310oc b) 3200c c) 380oc 16. Seal type elements instruments are used where process material is a) corrosive b) having impurities c) having high viscosity d) all the above 17.Metal used in Bi-metallic thermo-are having low thermal expansion is a) nickel Alloy b) Brass c) Copper d) Invar 18.Air purge system in level measurement a) It is suitable for use with corrosive jiouid b) Tank liquid does not enter the bubblet rube c) The gauge can be placed anywhere upto eoo feet d) All the above 19.For measurement of steam flow inhigh pressure high thmpr line it is best to use A) pitot tube B) orifice c) elbow d) flow nozzle 20. Hydrastep level measurement in Boiler drur is based on a) Variaable capacity principle b) variable conductivity principle / resistivity principle c) conduction rod principle d) ultrasonic principle 21. Distance between the electrodes of the hydrasteps except extreme two are a) 500 mm b) 200 mm c) 100mm d)50 mm 1.weights used in the Dead wight testers a) standrar market weitht at par b) stand ard market weight & weight of the plunaer plant form c) Ration of the standard market weight pepresenting actual weight. d) None of the above 2.winiscus in a glass tube Manometer of water is a) convex in shape b) concave in shape c) flat surfaced d) either of the a. b & c 3.34 mm hg absolute pressure in equivalent to a) 726 mm hg gauge pressure b) +726 mm hg vacuum c) 796 mm hg gauge pressure d) all the above

4. compound gauge is used for measurement when a) kprocess temperature varies inbothpositive and b) process pressure vcaries in both positive and negative side c) Many chemical compounds are to be measured bythe same gauge. d) Only for critical pressure measurement 5. span error in a bourdon tube pressure gauge is corrected at a) on the hair spring by adjusting tension b) postion change of the movement assembly block in the casing c) link connecting the Bourdontube with the movement assembly d) the elongaged slot in the sector lever by shifting the link screw 6. In ab bi- metallic thermometer, metals used for low temperature coefficient of expansion is a) steel alloy b) Nickelc span c) Invar d) Nickel vanadium alloy 7. cold junction compensation is essential in a) R.T.Ds b) Thermo couples c) Bi- metallic thermometers d) pyrometers 8. 1o kilvin change is equal to change in a) 33.6f b) 10c c) 10c d) none of the above 9.Some places, a constant standard temperature is maintained at the reference junction of a thermocouple to a) avoid cold junction compensation for bulk connections b) system facilitate cold junction compensation c) system where ambient temperature at reference junction does not change 10.The flow pattern ina fluid in laminar when a) Flow is ambulant b) Flow is rapid with bends ahead c) Flow is straight and turbulent d) When there is no restrictor in the line 11.In a hydra- step level measurement the measurement is a) periodical b) intermittent c) in step by step d) continuous and in steps 12.detector unit senses the level in hydrastep a) for change in resistance of electrode continuously b) for change in voltage continuously c) for a limit value change in resistivity and hence the voltage drop d) for either change incurrent or in voltage 13.At SSTPS PA flow to mills is sensed by a) rotameter b) orifice plate c) flow nozzle d) pitot tube 14. vena contracta in flow pattern in a orifice plate is normally placed a) before the orifice plate

b) c) d)

after the orifice plate at the orifice point after the orifice plate depending on the velocity of the fluid a) b) c) d) head pressure friction high viscosity turbulanc e

11.

15. which of these factors help a fluid flow in a pipeline

12.

13.

16. While measuring thermo couple out put at reference junction the milivolt available is always less than the actual hot junction temperature equivalent 17. In two wire system rtd, it is impossible to get lead resistence change compensated 18. Rosemount level transmitter used inDeaerator level measurement sendes the level change in capacitance for change in capacitance for change in di-electric constant between the 19.mercury filled (MST) thermometers have linear scale 20.Rotameter works on differential pressure theory 1. In a Bourdon Tube pressure gauge for span abjustment we have a) position of the points b) shoulder screw c) Angularit gcmew d) Hair spring 2. Syphon bends used to protect the pressure gauges a) when pressure to be measured is corrosive liquid b) when pressure to be measured is hot liquid c) when pressure tobe measured is very cold liquid d) All of the above 3. copoer resistance Thermometer will hava a) Ro = 100 0hm b) Ro = 64 0hm c) Ro = 53 0hm d) Ro = 425 0hm 4. In differential pressure metbod rate off flow is propn a) square of the diffarential pressure b) square root of the differential pressurs c) velocity of the fluid d) velocity and pessure of the llquid 5. In SSTPP Main ateam flow is measured by a) orifice plate b) pilot tube c) venturi tube d) flow nozzle 6. two metals are used inbi- metal the rmometefr. The used in the low expansion strip is. a) nickel alloy b) Brass c) Iron d) Invar 7. Using International T/c Reference Tables for type k : The rmo- couplw, work out the required unjectionvoltag To cheqk a 0-600oc in dicator at f.s.d. assume a cold Juretill temperature (at the indicator terminals) of 30oc 8. reference gas used in zireonia probe for oxygen measie a) clean and prue hydrogen b) clean and pure oxygen c) clean and pure normal air d) clean and pune nitrogen 9. In staga SSTPS) the ph measuring ekectrodes used aro a) calome b) Glasss c) Hydrogen d) C & b 10. sodium analyzer is used to detect; :

14.

15.

a) condenser tube leakage b) boilefr tube leakage c) Hp Heater tybe leakage d) Lp hiter tube leakage Tempefrature maintained in zireonia probe is: a) 8230c b) 4830c c) 8490c e) 8430c the oil pump will take start when the pressure falls at in hp / lp bypass) in 200mw. a) 100kg/cm2 b) 110kg/ cm2 c) 150kg/ cm2 d) 90kg/cm2 Number of control loops inhp bypass system are; a) two b) four c) six d) seven the standrard gap of HPT differential expansion pick up is : a) 4mm b) 4.5mm c) 2.5m d) 3mm Voltageand frequency used for the axial shift measuring a) 24 v 195 b) 1923hz 10v c) 1953 hz 10v d) 110v 1953 hz

16. Direct operating pneumatic valve open when; a) supply pressure increased and signal pressure decreased b) supply pressure decreased and signal pressure increased c) signal pressure increased and supply pressure increased d) signal pressure increased 17.Air lock valve is used; a) to lock air pressure between positioner and air lock valv b) to tock air pressure between pressure regulatorand air lock valve c) to lock air pressure between pneumatic valve and air lock valve d) to lock air pressure between e.p converter and air pressure regulator 18. force balance transmitter is based on; a) two wire system b) four wire system c) pneumatic system d) force actuating transducer is balanced by feed back force 19. diamater of the nozzle in flapper nozzlsystem is: a) smaller than the restriction orifice b) greater than the restriction orifice c) equal to eachother d) not contable as it is immaterial for the measuring purp 20.A pneumatic amplifier is used to: a) in crease the signal pressure indirect operating valve b) decreasa the signal pressure indirect operating valve c) does not effect signal pressure d) in crease the signal volumetricaly, notin pressure 21. Basically two major types of measuring ckt are used in electronic recorders using balancing motors: a) moving coil type measurement ckt b) potontiometric ckt c) bridge ckt d) synchronous ckt 22. Motors used in ip 250l for dotting is a) 24v ac synchronous motor b) 24v ac induction motor c) 24v dc stepper motor d) 245v ac synchronous motor 23.Number of motors used in IP250l recorders are: a) two motors b) three motors

c) fcur motors d) five motors 24.voltage given to flexel-f recorders of ILK card after power unit is a) 15 0 + 15v dc b) 0 30 v dc c) 12 0 12 v dc d) 0 - 15 v dc 25. The switches used to cut of the supply to forward or reverse coil in electrical actuators are called 26. Draw a open sketch of control ckt for a electrical Actuator motor with reversing ckt holover ckt, 27. Atmospheric pressure at appoint like liquid pressured is caused by the; a) temperature of the air iin acertain volume b) density of air at a certain temperature c) volume of air at certainpressure d) volume of sur rmidg the eath used afroce to the earth core 28.Three shapes of a bourden tube are; ------------------------------------------29.The metal used in Bourden tube should not undergo . a) fatigue b) hysterisis c) creep d) all of the above 30.we used a dead weight tester to: a) Test dead weights b) Measure proeess pressure accurately c) Produce high presaure d) Calibrate pressure instrument 31.In a lvdt pressure in dieator the output voltage varies in proportion to the position of the magetice--------------32.In a venturi tube the fluid pressure is least where the tube is most -------------------33. which of these factor actually help a fluid to flow in a pipe: a) Head b) Friction c) Viscosity d) All of the above 34. To achieve the needed throat velocity the flow in a venturi tube must ( increase/ decrease) its static pressure 35. for measuring flow in a high pressure, high temperature steam it is best to use a ( flow nozzle/ ventruri tube/ orifice plate) 36. When the DP values of the fluid flow is low what measuring defvice is useful: a) Pitot tube b) Orifice plate c) Dp transmitters d) Elbow mounted device 37. The fluid measured by a rotameter flows from the a) Top to bottom b) Mid point to top c) Bottom to the top d) mid point to the bottom 38. As the rotameter float rises in the tube the area available for fluid flow (increase/ dacrease) 39. turbine and magnetic flow meters are (vloujetric/ mass) flow measuring device 40. The rotor of a turbine flow meter spins at a rate proportional to the -------of the fluid flowing through the meter . 41. submerged displacers are not affected by rapid change in liquid level . TRUE/ FALSE 42. Hydrastep is superior than other method for drum level measurement. a) smaller error incurred due to change in liquid densities b) steam and water level seperation is easily detectable c) maintenance is less and more reliable d) all of the above 43.Hydrastep level measurement in the boiler drum is besed on a) capacity principle b) conductivity principle

c) hend pressure principle d) Ultrasonic principle 44. likquid in metal thermometer to choice liquid the consideration to be done. a) It musft be a large coafficient of cubical expansion b) It s vapour pressure should be very low c) It is desinable that liquid expan uniformly with risc Of temperature d) All of the above 45. Gas filled the rmometers are basad on the principle that the pressure of a confined gas: a) is unaffected by temperatue changes b) varies directly with absolute tempefrature c) in crease as temperature increases d) decrease as valume decreased 46. The bulbs of filled system thermometers are usually made of a) copper b) glass c) plastic d) stainless steel 47. To measure temperature by RTD the bridge circuit is connedted by 3 wire system: a) To oliminate extra leasd resi stsance b) To increase the bridge cirduit sensitivity c) To redfuce the galvanome ter current 48. Which manometer is used for thevery low pressure calibrat a) well type b) Inclined c) U tube d) Straight limb 49. Actual gauge Upscale reading down scale pressure kg / cm2 reading kg / cm2 ----------------------------------------------------10 08 08 30 28 28 50 48 48 70 68 68 90 88 88 --------------------------------------------------------------------------In a o 100kg / cm2 pressure gauge above results found during the calibration , the result is a) range / span error b) angu larity error c) zero error d) None of the above 50.Show below a skeftch of a typical level measuring system: Calcul ate the calibration figure for the level transmitter Giving in tabular form required in put pressure ( in meter) Reading on control room indicator. In the above figure the recorder will indicate a) 470oc b) 53o0c c) 500oc d) 630oc 51. Three in dentical tanks are fitted with a pressure type level system as shown: Assuming tey have not beeb corrected forhead error, What will be the reading ( in mm H20 ) on the gauges when all three tanks are empty. 52. power cylinders are used to actuae: a) control valves in water line b) contols drives c) open / close gates d) Both B and c 53. positieners used in penumaftic actuator; a) positioner of the aetuator exaetly as jper slgnal one makes the respense time faster b) positiensf the collector c) sendsbeck the pesition of the actuator open ing to the ucb indioetor d) sends the feed back signal of the actuator openings to the controller 54. what is axial shift 55. HP/ LP bypass system uses------- make actuators

speeed of recordr can be a) Increased b) Remains constant c) Dedreased d) Increased or deereasec 57. Hydrazine monitoring in the boiler insnecessary to: a) Linmt the oxgon content in the beiler meter b) Pravent excessive hydrazine dozing inkthe boiler water c) To prevent axcessive foaming in the boiler drum d) None of the above 58. Conductivity measurement is necessary to find--------content in the feed water 59.olybdenum blue methsd kis used in : a) disselvesd oxgen measurement b) co monitering c) Hydrazine monitoring d) Silica analyzer 60.positioner used in pneumatic actuaftor; positions of the aetuater oxactly as per sigral and makes the response time faster b) positions the centroiler c) sonds back the positien of the actuater opening to the UCB indicator d) sends the feed back signal of theactuator opening to the controller 61. Vibratian pickups are mounted on --------------of to total number of which are -------------------- in 2000MW. 62. Liquid filled inmanemeter used forhigh pressure measure ment is a) Alcohol b) Silicen c) Whater e) Mercury 63. When gauge pressure reads- 250 atm the absolute pressure will be: a) 1.010 atm . b) 0.750 atm. c) 0.510 atm. d) 0. 750 atm. 64. 150c is equal to: a) 79oF b) 69oF c) 50 oF d) 59oF 65. Metals used for RTD element are: a) -----------b) ------------c) ------------66. Compensating cables are used fer: a) Ambient temperature compensetien Field temperature cempensatien b) To cut down in stallotion cost c) To aveid forming of ane ther junetien of two dissimilar metals (the rmoceuple) 67.cold junction compensation is required at : a) RTD het end junction b) The rmocouple het junction c) The rmocouple cold junction at jeasuring end d) All of the above 68. Standard pneumatic signals used inpressure or temopreture transmitters; a) 0- 15PSI b) 2-10kg/cmcm c) 0.2 1kg/cmcm d) none of the above 69. Temperature recerder reading in 350 o c . Ambient tempe 30oc / What will be the rmocouple mv equivalent temperature? a) 510 oc b) 310oc c) 320oc d) 38oc a)

56.

1.Which manometer is used for the low pressure calibration: a) well Type Manometer b) Inclined tube Manometer c) U- tube Manometer d) Straight limb manometer 2.Absolute pressure is: a) Gauge pressure b) Gauge pressure + Atmospheric pressure c) Gauge pressure Atmosphefric pressure d) None of the above. 3.If you use murcury as liquidin a manometer, the surface will be; a) Horizontal b) Concave c) Convex d) None of the above 4.In a Bourdon tube pressure gauge for span adjustment we have to adjust; a) position of the poister b) Quadrant screw c) Angularity screw d) Hair spring 5 Actual gauge Up scale reading Pressure Reading kg/cm2 10 30 50 70 90 8 28 48 68 88

Down scale reading kg/ cm2 8 28 48 68 88

In a o 100 kg. Cm2 pressure gauge the above results found during calibration , The result is : a) range/ Span error b) Angularity error c) Zero error d) None of the above 6. pressure Measured by water filling u tube manomeftefr 1360 kg/m2 what will be measured value if we replace warter by Mercry a) 136mm hg b) 100mm hg c) 23.6mm hg d) 360mm hg 7. In Bi Metallec Therometer used for low expansion strip is a) Nickel alloy b) Brass c) Iron d) Invar 8. freezing point (temp of Kelvin Thermomefter is a) 2730c b) o 0c c) 32 0c d) None of the above . 9. 150c is equal to : a) 790 F b) 69 0 F c) 59 0 F d) 45 0 F 10. when there is short circuit occurs across the resistance in an RTD (resisftance Thermometer) would that indicated in the control instruments a) high b) Low c) Normal d) None of the above. 11. List of one metal commonly used R.T.D. ssensor: 12. Hydrostatic pressure of water in an open tank depends on: a) the diameter of the tank b) the depth of the water c) The pressure at the surface

d) 13. a) b) c) d) 14. a) b) c) d) 15.

16. required: a) b) c) d) 17.

None of the above The specific gravity of a liquid is: Weight of 1 cu ft of the liquid Its weight mul- iplied by its volume Its density per unit volume The ratio of its density to waters density. Rotamemter works on the principle of : Variables pressure Variable area Weight of the float None of the above in a state of solution HP value is : the solution is acidic The solution is alkaline The solution is neutral None of the above for operating pneumatic control valve air signal is

a) b) c) d) 28. a) b) c) d) 29. a) b) c) d) 30. a) b) c) d) 31. a) b) c) d) 32. silcon diaod; a) b) c) d) 33. a) b) c) d) 34. a) b) c) d) 35. a) b) c) d) 36.

3to 15 PSI 4 to 20 PSI 1 to 2 kg/ cm2 0.3 to kh /cm2 Out put the brikdge rectifier circuit shouid be: a) b) c) d) 18. Identify which of the following configurations indicate forward biased junctilons diode: 19. The above symbol is a: a) P N P Transistefr b) Zener diod c) NPN Transister d) Semiconductor diod 20. a) 56 khm+ 10% c) 68 khm+ 5% d) 100 khm+20% d) 560khm + 10% 21. what is the binary equivalent of the Decimal member 71 a) 1 1 1 0 1 1 1 000 1 b) 1000 111 c) 11 00 101 d) 0101101 22. What is the current measured in the ammeter Ammeter Input resistance is 500 a) 500 MA b) 400 M A c) 5 A D) 4A 23. What is the equivalent resistance of the following ckt. a) 2.5 kilo 0hms, b) 2.38 kilo 0hms, c) 3.0 kilo 0hms d) 3.28 kilo 0hms 24. a diode can be used as a: a) full wave rectifier b) Isoloating AC Voltages c) Bypassing DC voltages d) half wave rectifier 25. What is the voltage measured in the voltmeter voltmeter has 1 kilo input resistance a) 1.43v b) 1.5 v c) 2.0 v d) 2.5 v 26. This symbol represents which component in the electronic ckts a) SCR b) Diac c) Triac d) Ujt 27. what is the out put of the transformer given below:

293. 33 v 165 v 400 v 250 v In principle, atmansformer behaves like a : inductilon motor d. c. shut motor synchronous motor d.c series motor. For high torque starting the following motor is preferred; squirrel cage inductionmotor d. c. motor slip ring to pe inductilonmotor synchronous motor For constant speed requirement at out put we nust use a synchronous motor special type inductionmotor d. c. motor with shunt and field resistance set at particular valve slip ring type inductilon motor . in the figure shown ( current transformer ) primary has got two turns primary has got three turns primary hot hot single turn None of the above What is the forward biasing voltage of a p. n. junction of 3v 1.7 2v 0.6v zener diaode has a break down oltage when ; forward biased reverse biased in both forward and revers biased conditions none of the above Which componet is generally used as a voltage stabilizer Diaode Unijuction transistor FET Zener diode Triac is normally referred as a : When forward biased Back to back connected scr Back to back connected transistor Back to back connected zener diode SCR can conduct ;

a) When forward biased b) When recerse biased c) When forward biased ad triggering fulse is present d) when reverse biased and triggering fulse is present 37. thermocouple develops milliolts (emf) across its wires when hot and cold junctions are at defferent temperatures. This effect is called ; a) faradays effect b) hall effect c) Newtons effect d) None of the above 38. for remote indication (long distance and high temperature (of the order of 600oc ) aplocations, the temperature sensor used is : a) Mercury in steel temperature gauge b) Bimetallic Thermometer c) Thermo couples d) Resistance Thermometer; 39. for high pressures sensing normally which sensor is used: a) diaphragm b) Bourdon c) Bellows d) Any of the three above. 40. which gate is called a universal gate : a) AND b) NAND c) NOR

d) 41.

OR which is the gate that can have following truth table: Input 1 1 0 1 0 Input 2 1 0 0 1 input 0 0 1 1

a) b) c) d) 42. variable pulse a) b) c) d) 43. a) b) c) d) 44. 45. conductivity

AND OR NOR EX OR which circuit can be used as a frequency generato with width: Astablle multivibrator Bistable multivibrator Sschmitt trigger ckt Monostable multi vibrator Diaphragm isolation pressure gauges are used for : Accuracy Reliability Protecting the sensing element Orresting leakages 3- 15 PSI signal is widely used in pneumatic instruments. State the reason: Why is temperature compensatilon used in the

measurement? 46. In a typical pressure transmitter pressure is sensed and converted tomotion and then motion is converted to Electrical Name the d equipment which converts notion to electrical quantity: 47. Find the value of I 2 in the following circuit: 48. The equation expressing the relationship among pressure, temperature and volume of a gas is : a) p = VRT b) PV =NRT c) PV = PRT d) V= NRP 49. We use a deadwight tester to a) test deadweights b) Measure process pressures accurately c) Produce high pressures d) Calibrate pressure instruments. 50. Pressure is define as a) force per unit of area b) FXA c) A/ F None of the above

También podría gustarte