Está en la página 1de 79

CARMAN WI Operation Manual

This manual is based on Windows XP O/S. If you are using another other O/S, please refer to the related-O/S manual.

CONTENTS
Overview of Carman Wi Cautions in Use I. II. Parts of Main Module.................................................5 Power Supply.............................................................6

III. Components Lists.......................................................7 IV. Specification..............................................................10 V. Pictures of Components............................................11

VI. Software Installation.................................................16 VII. Connection by USB...................................................32 VIII. Main Screen..............................................................34 IX. Vehicle Diagnosis.....................................................36 X. Program Download....................................................51

XI. Saved Data.................................................................52 XII. Internet Information..................................................54 XIII. Calculator..................................................................55 XIV. Configuration.............................................................56 [Appendix] Software Installation (O/S: WIN 2000, Vista)
CARMAN Wi Operation Manual 2

Overview of Carman Wi
Carman Wi checks the vehicle defects by cable or wireless as a self-diagnostic sensor scan tool. As it is a compact size and wireless LAN communication type, users can diagnose the vehicle defects more quickly and conveniently. Functional Summary - Diagnostic function of Korean, Japanese, European, American Vehicles - Vehicle communication function by Wireless LAN, USB method - Work efficiency connecting the existing PC - Saved Data Search function

Please, try to use the software installation to install the program, after reading an operating manual from the beginning to the end.

2007. 6. Nextech Co., Ltd

CARMAN Wi Operation Manual 3

Cautions in use
Safety Instruction
Cautions in Use Carman Wi described in this manual was manufactured for those who have the basic knowledge required for its use. Users should follow the safety instructions for safe and efficient use of the product. The cautions of use are as follows: Do not drop the product. Never use the product without the rubber boot in place. Do not put the product on a distributor or high-tension cables. Even though Carman Wi is manufactured to internally prevent the interference from the electromagnetic waves, the strong interference by excessive electromagnetic waves may damage the product. The strong surge or electric shock applied to the power cable may damage the power supply unit of the product. So, do not use the product while the power supply is unstable. The voltage rating of the AC/DC adapter is 12V DC. Be sure to use an AC/DC adaptor with the rated voltage.

CARMAN Wi Operation Manual 4

I. Parts of the Main Module


1. Main module

[ I-1 : ] [Fig. I-1: Front view] Status sign LED Displays the status of Carman Wi. *POWER: Displays power on or off. *COM: Displays communication status.

[Fig. I-2 : Side view] 1. RS-232 : Other equipment interface using the RS232 terminal. 2. USB : It supports USB 2.0 standard and connects PC. 3. Power Connector : It powers up by an AC/DC adapter. The unit powers up by the communication with OBD-II standard vehicle without an AC/DC adapter.

CARMAN Wi Operation Manual 5

II. Power Supply


Carman Wi can be supplied with power in four ways as follows: 1. Cigar Lighter Cable
The cigar lighter cable can supply power to the product. However, when the vehicle ignition switch is off or upon starting a vehicle, power is not supplied to the cigar lighter socket.

2. Vehicle Battery
Connect the red clip of the battery connection cable to the (+) battery terminal, and black clip to the (-) terminal. Connect the cigar lighter cable between the battery connection cable and the product. In this case, power is supplied anytime regardless of the ignition switch status or vehicle starting. Be careful when connecting the cable, as incorrect polarity may damage the mainframe.

3. DLC Main Cable


Where the vehicle satisfies the OBD-II communication convention and uses a 16-pin diagnostic connector, the DLC main cable can supply power to the product directly without a separate power supply.

4. AC/DC Adapter
If the AC/DC adapter is used as a power supply, the battery may be charged automatically, and it may be used as the power source of the mainframe.

CARMAN Wi Operation Manual 6

III. Component List

1. Components
1) Standard/ Asian kit
NO. PART NUMBER 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 12000-10000 12000-11000 12000-11100 12000-11110 12000-11111 12000-12111 12000-12211 12000-12221 12000-12231 12000-12232 12000-12233 12000-12222 12000-13222 12000-13322 12000-13332 12000-14333 12000-14433 12000-14443 12000-20000 12000-22000 12000-22200 ITEMS CARMAN Wi MAIN MODULE OPERATION MANUAL PROGRAM CD USB CABLE BATTERY EX.CABLE DLC MAIN CABLE CIGAR LIGHTER CABLE AC/DC ADAPTOR AC POWER CORD WIRELESS LAN CF CARD USB 2.0 WIRELESS LAN CARD HYUNDAI/MITSUBISHI 12P KIA/MAZDA 6 PIN KIA 20 PIN DAEWOO/GM SSANGYONG 14 PIN SSANGYONG 20 PIN SAMSUNG 14 PIN TOYOTA,LEXUS(17R) TOYOTA,LEXUS(17C) HONDA 3PIN

CARMAN Wi Operation Manual 7

III. Component List


NO. PART NUMBER 22 23 24 25 26 12000-22220 12000-22222 12000-22221 12000-23222 12000-15544 ITEMS MAZDA "C" 17 PIN SUBARU 16 PIN-9 PIN MITSUBISHI 12P+16P HONDA 5PIN CARRYING CASE

2) Basic kit
NO. PART NUMBER 1 2 3 4 5 6 7 8 9 10 11 12000-10000 12000-11000 12000-11100 12000-11110 12000-11111 12000-12111 12000-12211 12000-12221 12000-12231 12000-12232 12000-12233 ITEMS CARMAN Wi MAIN MODULE OPERATION MANUAL PROGRAM CD USB CABLE BATTERY EX.CABLE DLC MAIN CABLE CIGAR LIGHTER CABLE AC/DC ADAPTOR AC POWER CORD WIRELESS LAN CF CARD USB 2.0 WIRELESS LAN CARD

CARMAN Wi Operation Manual 8

III. Component list


3) Europe
NO. PART NUMBER 1 2 3 4 5 6 7 8 12000-30000 12000-33000 12000-33300 12000-33330 12000-33333 12000-34333 12000-34433 12000-34443 ITEMS PSA 30 PIN PSA 2 PIN RENAULT 12 PIN BENZ38 PIN PINBOARD BMW 20 PIN OPEL 10 PIN AUDI/VW 2 PIN +2 PIN BENZ 3 LINEAR

4) USA
NO. PART NUMBER 1 2 12000-40000 12000-44000 ITEMS FORD HOLDEN 6 PIN

CARMAN Wi Operation Manual 9

IV. Specifications

System Specifications
1) Carman Wi
Memory : 32MB Internal Flash Memory Operating Voltage : 7-36V DC INPUT Frequency : 2.4~2.48 GHz Electricity Consumption : 4.5 Watt Temperature range : 0~60 Either NET : IEEE 802.11b 11M bps DLC communication : OBD-I OBD-(ISO 9141-2) OBD-(SAE-J1850) KWP-2000 C.A.N

2) PC recommendation
Hardware CPU: Minimum Pentium 4 USB: Minimum 2.0 Software O/S: Minimum Windows 2000 (Windows XP)

CARMAN Wi Operation Manual 10

V. Pictures of Components
Pictures of Components

MAIN MODULE

CIGAR LIGHTER CABLE

BATTERY EX.CABLE

DLC MAIN CABLE

USB CABLE

OPERATION MANUAL

PROGRAM CD

CARMAN Wi Operation Manual 11

V. Pictures of Components

HYUNDAI/ MITSUBISHI CABLE (12P)

KIA ADAPTER (20P)

KIA/MAZDA ADAPTER (6+1P)

DAEWOO/GM ADAPTER (12P)

SSANGYONG ADAPTER (20P)

SAMSUNG/NISSAN ADAPTER (14P)

SSANGYONG ADAPTER (14P)

CARMAN Wi Operation Manual 12

V. Pictures of Components

HONDA ADAPTER (3P))

TOYOTA ADAPTER (17R)

SUBARU ADAPTER (9P)

MAZDA ADAPTER (17C)

TOYOTA ADAPTER (17C)

HONDA ADAPTER (5P)

CARMAN Wi Operation Manual 13

V. Pictures of Components

BMW ADAPTER (20P)

OPEL ADAPTER (10P)

BENZ CABLE (3 LINER)

AUDI/VW CABLE(2+2P)

BENZ PIN BOARD (38P)

CARMAN Wi Operation Manual 14

V. Pictures of Components

PSA CABLE(2PIN)

PSA CABLE(30P)

RENAULT CABLE (12P)

HOLDEN CABLE (6P)

FORD ADAPTER (17P)

CARMAN Wi Operation Manual 15

VI. Software Installation


How to set up the Carman Wi PC Program. 1. Insert a Carman Wi program CD into the computer driver. try to open the relevant driver. 2. Double click the [Carman Wi_20070622_25_AMPD] icon, which is located in the [Carman Wi PC Program] folder.

3. InstallShield Wizard dialog appears.

4. Once installation is complete, Installation Complete dialog appears. To complete, click Finish.

CARMAN Wi Operation Manual 16

VI. Software Installation


5. A new Carman Wi icon is shown on your desktop.

6. Double click the Carman Wi icon to open the following program.

As far as here, we explain how to set up the Carman Wi program.

CARMAN Wi Operation Manual 17

VI. Software Installation


How to set up a wireless USB LAN card called WL-54G made by Unicorn. 1. Insert a Carman Wi program CD into your computer driver. 2. Double click the [Setup] icon.

3. Once installation is completed, Installation Complete dialog appears. To complete the install, click Finish.

CARMAN Wi Operation Manual 18

VI. Software Installation


4. Connect a Wireless LAN Module(UNICORN) with the USB port in the computer. Turn on Carman Wi. Found New Hardware dialog appears on the taskbar.

5. Click the icon in the red square box on the taskbar.

6. Below screen will be shown.

Please find nextechXXX from the Available Network on the left side of the screen. If there is no nextechXXX on the Available Network, click Refresh button to find nextechXXX again. If you find it, please double click it. ( The main unit of Carman Wi should be powered on during the procedure. )

CARMAN Wi Operation Manual 19

VI. Software Installation


7. Click Yes to continue.

Click More Setting to continue. 8. Click WEP Encryption Key Setting to continue.

9. Click Change to continue.

Please input the number 1234567891 in the Key Value #1 and click Apply button. After this procedures, close all screens.

CARMAN Wi Operation Manual 20

VI. Software Installation


10. Click the icon in the red square box on the taskbar.

Click Properties to continue. (The value of Network should be nextech)

Double Click Internet Protocol (TCP/IP) on the screen.

CARMAN Wi Operation Manual 21

VI. Software Installation


11. Input 100.1.X.XXX in the IP address and 255.0.0.0 in the Subnet mask. Then click OK button.

** How to set up the IP address ** Check the serial No. of Carman Wi. For example, if the serial number is 0077 as described in the picture, the first two digits 00will be used in the IP address without any changes. However, the next two digits77 should be changed as below ; 77+100=177 Then, input the changed number 177 in the IP address.

There are some USB slots for connecting a USB wireless LAN card with a PC. However, we recommend you to use one USB port. If you use other USB slots, the IP address that you set up will be changed. You will see a warning message and should set up TCP/IP newly, if you use the same IP address with different USB slots. (This applies to all computers using WINDOWS)

CARMAN Wi Operation Manual 22

VI. Software Installation


[Examples for setting IP address]
Ex 1) In case that the serial number of your scanner is [0123]

A = 01 B = 23 then, your IP address could be 100 . 1 . 1 . 123.

Ex 2) In case that the serial number of your scanner is [1234]

A = 12 B = 34 then, your IP address could be 100 . 1 . 12 . 134.

Although you follow this step, your IP address may collide with others. If you meet the this problem, try to add 1 to the last 3 digits for avoiding the IP collision.

Ex1) 100. 1. 1. 123 -> 100. 1. 1. 124 Ex2) 100. 1. 12. 134 -> 100. 1. 12. 135

CARMAN Wi Operation Manual 23

VI. Software Installation


12. Follow these steps : [Start] [Settings] [Control Panel] [Security Center] [Windows Firewall].

CARMAN Wi Operation Manual 24

VI. Software Installation


13. After you see the following screen, click the [Exceptions] function at the top of the screen, then click the [Add Program] button to continue the next step.

14. Add the exception clause as follows ;

Click the CarmanWi program, then click the [Add Program] button to set up an exception clause related the programs of Carman Wi from a firewall.

CARMAN Wi Operation Manual 25

VI. Software Installation

After all of the programs related Carman Wi are added to your system, click the [OK] button to finish setting up a firewall.

If setting the firewall is not correct, you may have a problem while you are checking a vehicle.

CARMAN Wi Operation Manual 26

VI. Software Installation


15. Double click Carman Wi icon on the desktop to start the following program.

After the screen appears, click CONFIGURATION to continue. 16. Choose Wirless Lan on the COM PORT SET and click Search WLAN to continue.

CARMAN Wi Operation Manual 27

VI. Software Installation


17. If the same IP address on the backside of Carman Wi body appears on the screen, click OK button. (The IP address should be shown on the screen.)

18. Click VEHICLE DIAGNOSIS to start the vehicle diagnostic program.

CARMAN Wi Operation Manual 28

VI. Software Installation


19. When two or more Carman Wi are used at the same place, a problem could be happened because the IP addresses can clash each other. If you face the same problem, follow the steps ; 1) Turn off Carman Wi and remove the CF card from the main unit of Carman Wi. 2) Connect Carman Wi with the PC by using the USB cable. (See page 29) 3) Turn on Carman Wi. 4) After operating the Carman Wi program, go to Configuation. 5) Select Wireless function.

6) After clicking the READ button, You can see the present IP address of the Carman Wi

CARMAN Wi Operation Manual 29

VI. Software Installation


7) Change the end of the IP address at users discretion. Ex) 105->100

And click WRITE button. 8) Click OK button when you see below box.

9) After checking the IP address, then use Carman Wi. To check the address, click READ button again.

CARMAN Wi Operation Manual 30

VI. Software Installation

Caution Wireless communication could be interrupted by any obstacles in between Wireless LAN card of Carman Wi and UNICORN Wireless LAN antenna.

Wireless communication is highly sensitive within 10m, but we recommend using it within 5m.

CARMAN Wi Operation Manual 31

VII. Connection by USB

A USB cable can be used when Carman Wi can not be connected to PC by wireless LAN or when you want to download the diagnosis program. Connect a USB cable to the PC after you insert an installation CD into the PC and provide Carman Wi with power.

Tips) USB driver is on the driver CD provided. Insert driver CD into the CD-ROM drive and select the CD-ROM drive.

CARMAN Wi Operation Manual 32

VII. Connection by USB

After setting up the USB driver, start the program and click Configuration button. As you can see in the left picture, select USB and click OK button.

Please connect Carman Wi powered by 12V adapter with PC. 12V adapter is a standard component. Tips) Diagnostic connector might be short when Carman Wi is connected with PC by USB. Then, please use an extension cable provided. Tips)
If you meet the following cases while you are using Carman Wi with a USB cable, please try to take the USB cable out from Carman Wi or turn off/on Carman Wi again. Case 1 : Missing connection between Carman Wi with a USB cable Case 2 : Cutting the power supply of Carman Wi

CARMAN Wi Operation Manual 33

VIII. Main screen


Screen Layout and Description

1. Vehicle Diagnosis

: Provides the function to diagnose the vehicle and display sensor outputs via communication with a vehicle.

2. Program Download

: Above item can be used when you download the saved data in Hard disk to Carman Wi. Also, you can change the units of Speed, Temperature, Pressure, Degrees of an angle and others if you press SYSTEM SETUP.

CARMAN Wi Operation Manual 34

VIII. Main screen


3. Saved Data

: Displays the saved data from sensors, waveforms and captured images.

4. Internet

: Press tap INTERNET INFORMATION 5. Calculator

: Provides a general calculator and unit conversion function. 6. Configuration

: Provides the function to change or modify the basic settings.

CARMAN Wi Operation Manual 35

IX. Vehicle diagnosis 1. Vehicle connection and diagnosis program


1) Vehicle connection
. In other to use the Carman Wi, be sure to connect the main cable to the DLC connector of Carman Wi. - Try pushing the main cable until you can hear Click sound. . Try to connect the cable to the vehicle after checking the location and specification of a connector. - Communication error will occur from connection problems.

[ Fig. X-1 How to connect a main cable to a vehicle] Caution !) Please, check the direction of the cable and the manufacture of vehicles first before trying to connect the cable to the vehicle. Some of vehicles cannot be suppy the Wi with vehicle power via a main cable. If so, you should use a cigar cable to provide Carman Wi with power.

CARMAN Wi Operation Manual 36

IX. Vehicle diagnosis 2. Communication


- You can view the help for the parts of four systems Engine / Engine (LPG) / ABS / Suspension.

Fig. I-6 Diagnosis Program - Connecting to ECM is displayed, and then the communication becomes active

Fig. I-7 Connecting ECM

CARMAN Wi Operation Manual 37

IX. Vehicle diagnosis 3. Diagnosis Program


1) Main Screen

Fig. I-8 Diagnosis Main Screen Procedure for selecting a diagnosis menu Shows the procedure for selecting a diagnosis menu.

Country -> Maker -> Vehicle Type -> System -> System Spec. Icon for returning to a main screen : Tap on this icon to change a size of a screen to minimum. : Pressing this icon on any menu displays the main menu again. : Tap on this icon to move a main screen. Trouble Code You can display the trouble code of the system, and delete a trouble code. Sensor

You can search the current values of the sensors of the relevant system

CARMAN Wi Operation Manual 38

IX. Vehicle diagnosis


ACTUATOR You can check if the system is normal by forcibly starting or stopping the actuators of the relevant system. OTHER You can check the system spec and use various supplementary functions. The actual functions will depend on the vehicle selected DIAG MENU Pressing this menu displays the diagnosis main screen again on any screen. Fig. I-8 Diagnosis Main Screen HOME Pressing this menu displays the system selection screen again on any screen. Fig. I-6 Diagnosis Program PRINT You can make a copy of the present screen. Cutting the power supply might be happened in the following case. 1. If you get rid of a main cable and connect the cable to the other vehicles before all communications are finished between Carman wi and a vehicle. 2. Turning an ignition key of a car which is suppied with power by a cigar lighter cable. Then, the following message will be shown on your PC after 1 min. Please, do not operate Carman Wi before you can see the message and try to follow the step of the message.

(If Carman Wi and your PC are connected by a USB cable, the message will be displayed more quickly.)

CARMAN Wi Operation Manual 39

IX. Vehicle diagnosis


2) Major Functions
. Trouble Code If troubles are detected, the trouble code, number of trouble codes and description are displayed. If there are some troubles, List is displayed as show in the Fig. I-9.

Fig. I-9 Trouble Diagnosis Screen : If there is a fault code, tap on ERASE to delete the code. Deletes the displayed trouble code.

Be sure to delete trouble codes only when the ignition key is on and an engine is off. A trouble code may not be erased, or abnormal problems may occur if deleting codes with the engine running. TIPS) A temporary trouble code may be erased without repairing. But if the fault is still valid, the code is erased temporarily, and will then be displayed again.

CARMAN Wi Operation Manual 40

IX. Vehicle diagnosis


. SENSOR You can analyze the changes in the sensor or actuator values.

Fig. I-10

Service Data Screen (Text view)

: Tap on +FILE to select the record mode or open a file. Then and are activated.

Fig. I-11 Text View Storage Screen : Tap on RECORD to start a recording. You can save the value changes of the (fixed) items you have selected for later analysis. Recording will continue until RECORD is pressed again. : Tap on OPEN to open a recorded event. You can move to a screen where you can select the saved data.

CARMAN Wi Operation Manual 41

IX. Vehicle diagnosis

: Tap on +SEL ITEM to add a sensor item on a Text screen. When the sensor data list pane on the Screen is activated, you can select new items or delete previously selected items.

Fig. I-12 Text View Sel Item Screen : Select an item to add, and then tap on ADD FIX. A new item is fixed, and you can see the data changes on the graph.

: Select an item to unfix, and then tap on UNFIX. The selected item is released from fixing.

CARMAN Wi Operation Manual 42

IX. Vehicle diagnosis

Fig. I-13 Service Data Screen (Graph view) : Tap on TEXT VIEW to return to the text screen. You can move to the text view screen in Fig. I-10 : Tap on +FILE to select the record mode or open a file. Then and are activated.

: Tap on RECORD to start a recording. You can save the value changes of the (fixed) items you have selected for later analysis. Recording will continue until RECORD is pressed again. : Tap on OPEN to open a recorded event. You can move to a screen where you can select the saved data.

CARMAN Wi Operation Manual 43

IX. Vehicle diagnosis

: Tap on +SEL ITEM to add a sensor item on a graph screen. When the sensor data list pane on the right side is activated, you can select new items or delete previously selected items.

Fig. I-14 Item Selection Screen : Select an item to add, and then tap on ADD FIX. A new item is fixed, and you can see the data changes on the graph.

: Select an item to unfix, and then tap on UNFIX. The selected item is released from fixing.

CARMAN Wi Operation Manual 44

IX. Vehicle diagnosis


/ : Tap on CONFIG to change the screen settings.

Icons necessary for screen settings are displayed on the right hand side.

Fig. I-15 Settings Screen 1 : Tap on VIEW CH + to increase the number of sensor items to be displayed on the screen. 4 items are displayed by default. But, the number can be increased up to 8. : Tap on VIEW CH - to decrease the number of sensor items to be displayed on the screen. The number can be decreased down to 1. : Tap on VIEW DATA to remove or replace the numeric data display on the graph. Data is displayed on the graph on the center of a screen. : Tap on VIEW RANGE to remove or replace the MIN/MAX values on the graph. Min/Max data is displayed on the right hand side of a graph.

CARMAN Wi Operation Manual 45

IX. Vehicle diagnosis

: Tap on VIEW NAME to remove or replace the data item names on the graph. The name is displayed on the left hand side of a graph. TIP) / /

Data is displayed on the graph by default. To remove the display data on the screen, tap on a relevant icon once. The icon then turns to a red color, and the data will not displayed on the screen.

: To zoom the graph displayed on the screen, in or out, tap on the CH icon until the desired sensors channel is displayed and then tap the MAX+ or MAX- icon. To observe the graphical wave of a test item in more detail , you can tap on + or - icon to zoom in or out the graph.
While connecting Carman Wi with a PC, Wire/Wireless communication could be stopped by changing system mode, Standby mode or hibernate. Then, you should connect Carman Wi with a PC again in the changed mode. Please, do not use Carman Wi in the Standby mode or hibernate of WINDOWS.

CARMAN Wi Operation Manual 46

IX. Vehicle diagnosis

: Tap on CONFIG / HOLD/RUN.

You can check the changes of the date through holding or running the screen..

Fig. I-16 Settings Screen 2 : Tap on HOLD/RUN. When you tap on "HOLD", the screen will be frozen and by tapping on "RUN" the screen will proceed again.

: Tap on PAGE to move the screen to backward or forward. You can check the saved screen by pages.

: Tap on "ZOOM" to zoom in or out the screen of the value. Default value is set up at 60 and you can zoom in and out by 10units.

CARMAN Wi Operation Manual 47

IX. Vehicle diagnosis


. ACTUATOR You can check if an actuator is normal by forcibly starting and stopping it.

Fig. Actuator Screen TIP) When you select a test item on the actuator list, the START and STOP icons on the left hand side are activated, and DURATION, test METHOD, and test CONDITION are displayed on the right hand side. : Tap on START to start or stop an actuator forcibly. Pressing this icon starts the actuation. : Tap on STOP to stop an actuator being tested. Pressing this icon stops the actuation.

CARMAN Wi Operation Manual 48

IX. Vehicle diagnosis


. OTHER You can check various adaptive values, system reset, and system specifications information.

Fig. OTHER Screen

Fig. Resetting Adaptive Values : Tap on Yes to confirm you want to delete the adaptive values or execute the selected command. Confirms the deletion of adaptive values or execution of a command once more before performing it.

CARMAN Wi Operation Manual 49

IX. Vehicle diagnosis


: Tap on No if you do not want to delete the adaptive values or execute the selected command. Confirms you do not want to carry out the deletion of adaptive values or execution of a command once more before performing it. : Tap on ENTER if you want to execute the command. Executes a command. : Tap on ESC to quit the function. Use this icon to cancel a command or quit a function. : Tap on the desired numbers. Use this icon to enter numbers.

: Tap on REST to reset the adaptive values. Resets the adaptive values or system resetting items.

CARMAN Wi Operation Manual 50

X. Program download
When you download new S/W programs, your PC and Carman Wi always should be connected by the USB cable.
After saving our S/W program in the folder of your PC, you can move the program s/w from your PC to Carman Wi by using theUSB cable. PC folder:[C drive] [Program file] [Nextech] [Carman

Wi] [SCAN_DATA]

Please, try to move our S/W program from your PC to Carman Wi after installation program called SCAN MODULE DOWNLOAD PROGRAM.

Fig. IX-1 Diagnosis Update Try to select the program whatever you want to move to Carman Wi after connecting your PC to Carman Wi then press the DOWNLOAD button. The program has to be saved in the following folder. [C drive] [Program file] [Nextech] [Carman Wi] [SCAN_DATA]

The units of Speed, Temperature, Pressure, Degrees of an angle and others can be changed in above screen. After changing the value of the items, press the WRITE SYSTEM button to save.

CARMAN Wi Operation Manual 51

XI. Saved data Saved Data of Diagnosis


You can view the data saved in the fault diagnosis function.

Fig. II-2 Saved Data in Fault Diagnosis Function

: Tap on GRAPH to check selected saved data file. You can check the saved data with this function. See Fig. II -3 Graph Screen

: Tap on DEL to delete a file. You can delete the selected data.

: Tap on RENAME to change a file name.

CARMAN Wi Operation Manual 52

XI. Saved data

Fig. II -3 Graph Screen

: Tap on LIST to return to the saved data list menu. Then, Fig. II -2 : Saved Data List Screen is displayed. : Tap on VIEW CH + to increase the number of signals displayed on a single screen The default number is 4. The number can be increased up to 8. : Tap on VIEW CH - to decrease the number of the signals displayed on a single screen. : Tap on UP to move up to the upper items to be displayed on the screen. : Tap on DOWN to move down to the lower items to be displayed on the screen.

CARMAN Wi Operation Manual 53

XII. Internet information


- You can connect with our homepage via internet.

Fig. IV Internet information

CARMAN Wi Operation Manual 54

XIII. Calculator
Provides a general calculator and unit conversion function.

Fig. V Calculator 1. Input data pane The data entered via the number panel is displayed.

2. Data input keys Can be used the same as a general calculator.

3. Unit setting pane You can select the unit of the number to be displayed on an input pane. If you select a unit, the result is converted to other units shown in the pane (4) and displayed under a corresponding unit symbol. 4. Unit result pane The entered number and unit are displayed here.

5. Unit conversion pane The entered number is converted to other units listed in this pane.

CARMAN Wi Operation Manual 55

XIV. Configuration
-

This is a function to test a key pat, check the system configuration information, and change the product settings.

Fig. VI-1 Configuration-1 Screen - Graph Config

: Tap to select Graph Set. (Fig. VI-2) You can set graph screen.
- DEVICE Set

DEVICE SETTING : You can select the device. Wireless Module IP : You can select the IP Address.

CARMAN Wi Operation Manual 56

XIV. Configuration
- You can change the Color of Line for your better analysis in case of being a lot of lines in the screen, which might confuse you at various similar line.

Fig. VI-2 Graph Config : Tap to select Bottom. You can select the bottom color of the screen.

: Tap to select Grid 1. As you can see in the Fig. VI-2, it makes you to analyze the data precisely while dividing the box among ten. You can change the color of the line of the horizontal axis using screen scale configuration.(Which is not shown on the picture above.).

: Tap to select Grid 2 You can change the color of the horizontal axis line on the screen

CARMAN Wi Operation Manual 57

XIV. Configuration

: Tap to select Center Grid. You can change the color of the vertical axis line on the screen. : Tap to select Cursor. You can change the color of the cursor which the point of time is selected by user. : Tap to select CH1/8. You can select from Channel 1 to Channel 8. : Tap to select CH Color. You can change the color of the selected channel. : Tap to select OK. The selected item will be saved. : Tap to select CANCEL. The selected item will be canceled. : Tap to select Default 1. Setting-up as default 1 value. : Tap to select Default 2. Setting-up as default 2 value.

CARMAN Wi Operation Manual 58

[Appendix]

A Software Installation
( Windows 2000 )

[Appendix]
Software Installation
How to set up the Carman Wi PC Program. 1. Put the Carman Wi program CD in the computer driver. 2. Open My Computer and click the CD driver icon.

Double Click Carman Wi PC Program icon, if you can see the same picture as below.

3. InstallShield Wizard dialog appears.

CARMAN Wi Operation Manual

[Appendix]
Software Installation
4. Once installation is complete, Installation Complete dialog appears. To complete, click Finish.

5. A new Carman Wi icon is shown on your desktop.

6. Double click the Carman Wi icon to open the following program.

As far as here, we explain how to set up the Carman Wi program.

CARMAN Wi Operation Manual

[Appendix]
Software Installation
How to set up a wireless USB LAN card called WL-54G made by Unicorn. 1. Insert UNICORN Wireless LAN program CD into computer driver. 2. Install Shield Wizard dialog appears.

3. Once installation is complete, Installation Complete dialog appears. To complete, click Finish.

CARMAN Wi Operation Manual

[Appendix]
Software Installation
4. Connect a Wireless LAN Module(UNICORN) with USB port in the computer. Turn on Carman Wi. Found New Hardware dialog appears on the taskbar.

5. Click the icon in the red square box on the taskbar.

6. Below screen will be shown.

Please find nextechXXX from the Available Network on the left side of the screen. If there is no nextechXXX on the Available Network,clickRefresh button to find nextechXXX again. If you find it, please double click it. ( The main unit of Carman Wi should be powered on during the procedure. )

CARMAN Wi Operation Manual

[Appendix]
Software Installation
7. Click Yes to continue.

Click More Setting to continue.

8. Click WEP Encryption Key Setting to continue.

CARMAN Wi Operation Manual

[Appendix]
Software Installation
9. Click Change to continue.

Please input the number 1234567891 in the Key Value #1 and click Apply button.After that, please close all the operating windows. 10. There is an icon called My Network Places on your computers desktop. Try to move a pointer on the icon and click the right button of a mouse and open a file called Properties.

CARMAN Wi Operation Manual

[Appendix]
Software Installation

You will be able to find an icon called Local Area Connection in above screen. If so, try to move a pointer on the icon and click the right button of a mouse and open a file called Properties.

Try to find a menu Internet Protocol(TCP/IP) and click the menu. After that, put the IP address. Refer to the following steps ;

CARMAN Wi Operation Manual

[Appendix]
Software Installation
11. Input 100.1.X.XXX in the IP address and 255.0.0.0 in the Subnet mask. Then click OK button.

** How to set up the IP address ** Check the serial No. of Carman Wi. For example, if the serial number is 0077 as described in the picture, the first two digits 00will be used in the IP address without any changes. However, the next two digits77 should be changed as below ; 77+100=177 Then, input the changed number 177 in the IP address.
There are some USB slots for connecting a

USB wireless LAN card with a PC. However, we recommend you to use one USB port. If you use other USB slots, the IP address that you set up will be changed. You will see a warning message and should set up TCP/IP newly, if you use the same IP address with different USB slots. (This applies to all computers using WINDOWS)

CARMAN Wi Operation Manual

[Appendix]

A Software Installation
( Windows Vista )

10

[Appendix]
Software Installation

** Cautions before an installation**


Someone, who uses the operating system called Windows Vista, can not connect a PC to Carman Wi by a wireess LAN card. (WL-54G) without the following steps because he can not use Internet Explorer and Carman Wi at the same time. Please, try to follow the step 1 to use Carman Wi. After using Carman Wi, try to follow the step 2 to use Internet Explorer. 1. Step 1 for using Carman Wi.
Move the pointer of the mouse on a [Computer] icon and click the right button of the mouse to open the following screen. Click the [ Manage] function.

After moving to the [Device Manager] function as the following screen, try to find the driver, which is connected to Internet Explorer, and click the right button of the mouse first. Then, click the [Disable] function.

After changing the function, you will be able to use Carman Wi and diagnose the vehicles. However, you can not use Internet Explorer in this condition.

CARMAN Wi Operation Manual

11

[Appendix]
Software Installation
2. Step 2 for using Internet Explorer
Please, try to follow the step 2 to use Internet Explorer, again. Move the pointer of the mouse on a [Computer] icon and click the right button of the mouse to open the following screen. Click the [ Manage] function.

After moving to the [Device Manager] function as the following screen, try to find the driver, which is connected to Internet Explorer, and click the right button of the mouse first. Then, click the [Enable] function.

After changing the function, you will be able to use Internet Explorer, again. However, you can not use Carman Wi in this condition.
Reference Using Carman Wi might be limited if you use Internet Explorer in Windows Vista system. However, you will be able to use Internet Explorer after a manual installation. See page 11

CARMAN Wi Operation Manual

12

[Appendix]
Software Installation
How to set up the Carman Wi PC Program. 1. Insert Carman Wi Program CD into computer driver. 2. Click the [Carman Wi PC Program] folder in the following picture.

Double click the installation program of Carman Wi Click the Allow button to continue.

3. The installation program will be started and set up as follows.

4. After finishing the installation, above picture will appear. Click the Finish button.

CARMAN Wi Operation Manual

13

[Appendix]
Software Installation
5. A new Carman Wi icon is shown on your desktop.

6.Double click the Carman Wi icon to open Carman Wi program.

As far as here, we explain how to set up the Carman Wi program.

CARMAN Wi Operation Manual

14

[Appendix]
Software Installation
How to set up a wireless USB LAN card called WL-54G made by Unicorn. 1. Insert the wireless CF LAN card in the main module of Carman Wi and supply the power in the main module. 2. Insert the wireless USB LAN card in the slot of the computer.

Click [Locate and install driver software] to continue.

Click [Yes, always search online] to continue.

Click [Next] to continue.

CARMAN Wi Operation Manual

15

[Appendix]
Software Installation
3. After finishing the installation, the following picture will appear.

Click the [Close] button.

4. Move the pointer of the mouse on a [Network] icon which is located on the desktop of the computer. Then, click the right button of the mouse to open the following screen and select the [Properties] function as below.

CARMAN Wi Operation Manual

16

[Appendix]
Software Installation
5. The following screen will be shown. Click [Connect to a network] function as follows.

Try to find [nextechXXX] and click the[Connect] button to continue. If there is no [nextechXXX] in above screen, click until you can find it.

CARMAN Wi Operation Manual

17

[Appendix]
Software Installation
6. Input the number 1234567891 into the [Security key or pass phrase] box and click the [Connect] button to move the next step.

Check the [Save this network] button and click the [Close] button.

CARMAN Wi Operation Manual

18

[Appendix]
Software Installation
7. The connection value has to be Wireless Network Connection(nextechXXX) If so, click the [View status] button.

8. The following screen will be shown. Click [Properties] button to move the next step and double click the [Internet Protocol Version 4(TCP/IPv4) function.

CARMAN Wi Operation Manual

19

[Appendix]
Software Installation
9. The following screen will be shown. Input the numbers into the [IP address] and [Subnet mask] box.

** How to set up the IP address **


Check the serial No. of Carman Wi. For example, if the serial number is 0077 as described in the picture, the first two digits 00will be used in the IP address without any changes. However, the next two digits77 should be changed as below ; 77+100=177 Then, input the changed number 177 in the IP address.
There are some USB slots for connecting a

USB wireless LAN card with a PC. However, we recommend you to use one USB port. If you use other USB slots, the IP address that you set up will be changed. You will see a warning message and should set up TCP/IP newly, if you use the same IP address with different USB slots. (This applies to all computers using WINDOWS)

CARMAN Wi Operation Manual

20

[Appendix]

This manual will be released for the better service without notice via our web-site. Refer to Nextechs homepage.

Wireless Scan Module Model No : Carman Wi Manufacturer : Nextech Co. Ltd FCC This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1)This device may not cause harmful interference, and (2)this device must accept any interface received, including interference that may cause undesired operation.

MADE IN KOREA

*Model : Carman Wi *Certificate Company : Nextech Co., Ltd./Korea *Certificate Number : NEX-CARMANWI-WLAN(A) *Certificate Date : 2007.6.5

CARMAN Wi Operation Manual

21

También podría gustarte