Está en la página 1de 1

SUBGERENCIA DE INSPECCION Y MANTENIMIENTO A COMPLEJOS DE PRODUCCION

PLACAS DE BLOQUEO (COMALES)


PSI
ESPESORES MINIMOS PARA PLACAS DE BLOQUEO EN PRUEBAS HIDROSTATICAS
PRESION
Lb/Pg² Kg/Cm² 2"ø 3"ø 4"ø 6"ø 8"ø 10"ø 12"ø 14"ø 16"ø 18"ø 20"ø 24"ø 30"ø 36"ø
100 7 0.166 0.187 0.210 0.256 0.303 0.349 0.395 0.442 0.448 0.533 0.580 0.672 0.817 0.822
200 14 0.183 0.212 0.246 0.311 0.376 0.442 0.507 0.574 0.638 0.702 0.768 0.899 1.104 1.306
300 21 0.196 0.232 0.272 0.353 0.433 0.513 0.593 0.675 0.753 0.832 0.913 1.073 1.325 1.571
400 28 0.207 0.249 0.295 0.388 0.481 0.573 0.666 0.760 0.851 0.942 1.035 1.220 1.510 1.795
500 35 0.216 0.264 0.315 0.419 0.523 0.623 0.730 0.835 0.936 1.038 1.143 1.349 1.674 1.992
600 42 0.225 0.277 0.334 0.447 0.561 0.674 0.788 0.903 1.014 1.125 1.240 1.466 1.822 2.170
700 49 0.233 0.290 0.351 0.473 0.596 0.718 0.841 0.965 1.085 1.205 1.329 1.573 1.958 2.334
800 56 0.240 0.300 0.366 0.497 0.628 0.759 0.890 1.023 1.151 1.280 1.412 1.673 2.084 2.487
900 63 0.248 0.311 0.381 0.520 0.659 0.798 0.937 1.078 1.214 1.350 1.491 1.767 2.203 2.630
1000 70 0.254 0.321 0.394 0.541 0.688 0.834 0.981 1.129 1.273 1.416 1.564 1.856 2.316 2.765
1100 77 0.260 0.331 0.408 0.561 0.715 0.869 1.022 1.178 1.329 1.479 1.635 1.941 2.423 2.894
1200 84 0.267 0.340 0.420 0.581 0.741 0.902 1.062 1.225 1.382 1.540 1.702 2.022 2.525 3.017
1300 91 0.272 0.350 0.432 0.599 0.767 0.934 1.101 1.270 1.434 1.597 1.766 2.099 2.623 3.136
1400 98 0.278 0.357 0.444 0.617 0.791 0.964 1.138 1.313 1.483 1.653 1.828 2.174 2.717 3.249
1500 105 0.283 0.365 0.455 0.635 0.814 0.994 1.173 1.355 1.531 1.707 1.868 2.246 2.808 3.359

DIAMETRO EXTERIOR PARA COMALES


150# 4" 5 1/4" 6 3/4" 8 5/8" 10 7/8" 13 1/4" 16" 17 1/2" 20 1/8" 21 1/2" 23 3/4" 28 1/8" 34 5/8" 41 1/8"
300# 4 1/4" 5 3/4" 7" 9 3/4" 12" 14 1/8" 16 1/2" 19" 21 1/8" 23 3/8" 25 5/8" 30 3/8" 37 3/8" 43 7/8"
600# 4 1/4" 5 3/4" 7 1/2" 10 3/8" 12 1/2" 15 5/8" 17 7/8" 19 1/4" 22 1/8" 24" 26 3/4" 31" 38 1/8" 44 3/8"

T= d.int. 3P 0.125 T= ESPESOR DE LA PLACA (PLGS)


16 SE d= DIAMETRO INTERIOR DEL TUBO (PLGS)
P= PRESION (Lbs/Plg2)
SE= ESFUERZO PERMISIBLE 32000 Lbs/Plg2)
0.125 FACTOR DE CORROSION