Está en la página 1de 1

HMC-MIC-FO-016

167 metros
HMC-MIC-SE-SR3 HMC-MIC-SE-RE3 CA-0 2
01-06
CA-0 2
01-06 HMC-MIC-SE-SX2
Sala Eléctrica Sala Eléctrica Sala Eléctrica
Solución Rica 3 Rectificadores 3 y 4 CA-0 4
01-06
CA-0 3
01-06
SX2
HMC-MIC-FO-017
138 metros

CA-0 1 CA-0 3 CA-0 1 CA-0 1 CA-0 4


01-06 01-12 01-12 01-12 01-06

HMC-MIC-FO-020 HMC-MIC-FO-015
HMC-MIC-FO-018
119 metros 435 metros
48 metros

CA-0 2 CA-0 3 CA-0 1


01-06 01-12 01-06

HMC-MIC-FO-021 HMC-MIC-FO-019
350 metros 1.399 metros
HMC-MIC-SE-ILS HMC-MIC-SE-LIN HMC-MIC-SE-RF2
Sala Abandonada N/A CA-0 1
Sala Eléctrica CA-0 1 CA-0 2
Sala Eléctrica Sala Eléctrica
Cerradura Trabada 01-06 07-12 01-06

ILS Subestación Lince Refino 2 y 3

CA-0 1
01-12

HMC-MIC-FO-008
437 metros
HMC-MIC-FO-005 HMC-MIC-FO-014
296 metros 406 metros

CA-0 3 CA-0 6 CA-0 5


01-08 01-12 01-12

HMC-MIC-FO-006
181 metros
HMC-MIC-FO-009 CA-0 2 CA-0 4
HMC-MIC-SE-SR1 HMC-MIC-SE-RE1 167 metros HMC-MIC-SE-SX1 01-12 01-12 HMC-MIC-SC-SXE HMC-MIC-OF-MDC
HMC-MIC-FO-013
Sala Eléctrica Sala Eléctrica CA-0 1
01-06
CA-0 8
01-06 Sala Eléctrica Sala Control CA-0 7
01-12
136 metros
CA-0 1
01-06 Oficina
Solución Rica 1 y 2 Rectificadores 1 y 2 SX1 CA-0 5
13-24
CA-0 4
13-24
SX-EW MDC
HMC-MIC-FO-007
170 metros
CA-0 1
01-12

CA-0 7 CA-0 5 CA-0 4 CA-06 CA-02 CA-0 5 CA-0 1


1-6
01-12 01-12 01-12 01-06 13-24 01-12
13-24

HMC-MIC-FO-010 HMC-MIC-FO-004
251 metros HMC-MIC-FO-002 HMC-MIC-FO-003
234 metros 192 metros 254 metros HMC-MIC-FO-012 HMC-MIC-FO-040
192 metros Corte a 89 metros

CA-0 1 CA-0 2
01-12 01-12
CA-0 4 CA-0 3 CA-0 2
01-12 01-18 01-12

HMC-MIC-OF-LAB N/ A
HMC-MIC-SS-INS HMC-MIC-SE-MDC
Oficina Sala Servidores Sala Eléctrica
Laboratorio Instrumentación MDC

CA-0 1
01-12

HMC-MIC-FO-001 HMC-MIC-FO-039 HMC-MIC-FO-011


1.113 metros Corte a 910 metros 925 metros

CA-0 5 CA-0 3 CA-0 5


12-24 01-12 N/ A

HMC-MIC-FO-030 HMC-MIC-FO-038 HMC-MIC-FO-035


HMC-MIC-SE-CGP 437 metros HMC-MIC-SE-CHF Corte a 606 metros HMC-MIC-SE-CTK 74 metros HMC-MIC-SC-OSM
Sala Eléctrica CA-0 1
01-06
CA-0 8
N/ A Sala Eléctrica CA-0 6
01-06
CA-0 1
07-12 Sala Eléctrica CA-0 1
01-06
CA-0 1
01-06 Sala Control
Chancado Grueso Propio Chancado Fino Cerro Estanque Osmosis
CA-0 8 CA-0 4
N/ A 01-12

CA0 2 CA-0 2 CA-0 1


01-06 01-04 HMC-MIC-FO-022 07-12

N/A CA-0 9 CA-0 9 CA-0 3 CA-0 1


509 metros
01-06 07-12 01-06 01-06 01-16
HMC-MIC-FO-029
667 metros

HMC-MIC-FO-037 HMC-MIC-FO-036
Filamentos Ocupados 79 metros

HMC-MIC-FO-023
367 metros
CA-0 1 CA-0 1
01-12 01-06
CA-0 2 CA-0 1 CA-0 2
01-06 07-12 01-06

HMC-MIC-FO-024
HMC-MIC-FO-025 203 metros
HMC-MIC-SE-CGC HMC-MIC-FO-026
312 metros HMC-MIC-SC-CGC HMC-MIC-SE-OSM
Sala Eléctrica 266 metros Sala Control Sala Eléctrica
Chancado Grueso Compra HMC-MIC-FO-028 Chancado Grueso Compra Osmosis
260 metros

HMC-MIC-FO-027
230 metros
CA-0 1
01-06

HMC-MIC-FO-031
319 metros

CA-0 1 CA-0 1 CA-0 1 CA-0 3 CA-0 1


07-12 13-16 01-06 01-06 01-16

HMC-MIC-FO-033
HMC-MIC-SE-10X HMC-MIC-SC-AGL 94 metros HMC-MIC-SE-AGL
Sala Eléctrica Sala Control CA-0 1
01-06
CA-0 1
17-22 Sala Eléctrica
10x60 Aglomerado Aglomerado

CA-0 1 CA-0 2
17-22 01-06

HMC-MIC-FO-032 HMC-MIC-FO-034
154 metros 517 metros

CA-0 1 CA-0 1 CA-0 1


01-06 07-12 01-06

HMC-MIC-SE-HAR HMC-MIC-PS-OSM
Sala Eléctrica Pasarela
Harneros Osmosis

MINERA HMC S.A. – FAENA MICHILLA

REFERENCIAS

REVISIONES
OF OF ICIN A
PS PASAREL A NO MBRE F IRMA F ECH A CÓDI GO PL ANO
PROYECTO UPGRADE DE SISTE MA D E CO NTROL D ISTRI BUI DO ABB 8 0 0XA
SC SALA DE CONTROL PROYECTO F .ME DINA 2 0/1 0 /2 3
SE SALA EL É CTRIC A DIBUJ O F .SOLI S 0 5/0 1 /2 4 HMC-MIC-DCS-TOPO
SUBPRO YECTO CERTI FI CACIÓN DE FI BRA ÓPTICA
SS SALA DE SE RVIDORE S REVI SO V.CARI LAO
FO CABL E DE F IBRA ÓPTI CA 1 0 5/0 1 /2 4 VE RSI ON I NICI AL F .SOLI S REVI SO M.DL F UEN TE F ECH A REVI SIÓN
CA CABE CERA D E F IBRA Ó PTI CA 0 2 1/1 0 /2 3 BORRADOR F .SOLI S REVI SO M.G ONZALE Z CON TE NI DO TOPOLOGÍA DE RED F.O. DE CONTROL DCS 05/01/24 1
CÓDI GO PL ANO DE SCRI PCIÓN N° F ECH A DE SCRI PCIÓN POR APROBO A.BRI TO

También podría gustarte