Está en la página 1de 1

BILL OF MATERIALS

FIELD MATERIALS

ITEM SIZE COMPONENT DESCRIPTION COMMODITY CODE QTY


==== (INCH) ======================= ================ ====
1"-WSA-1AFL062501-01-D
1 1 PIPE SMLS, ASTM A106 Gr. B, NACE, Max C.E, PE, HPPIPEA101101A1070 3.1 M
33 33
ASME B36.10,S-XXS
21 2 1X1 1
5 3 1X3/4 Reducing Tee 90 Degrees, ASTM A105, NACE + HIC, HCRT90A201J40A4090 1
Max C.E., CL 9000, SW, ASME B16.11
1 4 1 45 Degree Elbow, ASTM A105, NACE + HIC, Max CE, CL HC45ELA201B40A4090 1
28 9000, Socket Weld Ends, ASME B16.11,S-XXS
50 10
+1 214 1 5 1 90 Degree Elbow, ASTM A105, NACE + HIC, Max CE, CL HC90ELA201B40A4090 6 4
<D 39 9000, Socket Weld Ends, ASME B16.11,S-XXS
>1 8
>1 6 1 Spectacle Blind (Figure 8), ASTM A515 Gr. 70, HMF8SFA4011B0AD080 1
1"-WSA-1AFL062501-01-E 5
EL +116678
33 <C
20
131 NACE + HIC,Max C.E., CL 150, FF, B16.48
+1 13 7 3/4 NIPPLE 100 mm, ASTM A106 Gr. B, NACE, Max C.E., HPNIPPA101302A1070 1
1050 STEM SOUTH PE, ASME B36.10,S-XXS
0
19 8 3/4 HEX HEAD PLUG, ASTM A 105, NACE + HIC, Max C.E., HCPLUHA201300A4090 1
33 22 <E NPT, ASME B16.11
> 1 33
9 1 Socket Weld Flange, ASTM A105, NACE + HIC, Max HFSWFLA2018B0A3310 3
<G> 1 33 C.E., CL 150, RF, ASME B16.5,S-XXS
17
E02 12 18
95
10 1 SPIRAL WOUND GKT, 316/GRAPHITE - C. S. C RING/316 HGSPWGQ1041BGAA000 2
23 5 0 I. RING, 4.5 mm, CL 150, RF, ASME B16.20
6 10
0 16 11 1/2 Stud Bolt with 2 Heavy Hexagonal Nuts and 2 HBSW2NR001002A7000 4
TAIL N Washers, ASTMA193 Gr.B7/ A194 Gr.2H, DESIGN
7 16 33 94 ASME B18.2.1I B18.2.2 - 75 mm Length
<B> 1 2 10 14
1X1"NPD 9 15
75 <F> 1
7 8 VALVES / IN-LINE ITEMS
33 15 F9 G10 B11
10 33
13 12 1 Lift Check Valve Female Ends, ASTM A105, NACE + HVCL30A2014H0M106AM2 1
33
>1 HIC, MaxC.E., CL 1500, SW, Manufacturer
0 <H
+ 1550 12 F9 G10 Standard, TRIM: N 12
09 1
914

1 22C 13 1 Gate Valve Female Ends, ASTM A105, NACE + HIC, HVGA30A2014H1M106AMB 2
<I>
+1509

11
85

MaxC.E., CL 1500, SW, Manufacturer Standard,


23
33 E01 14 3/4
HW, TRIM:N 12
Gate Valve Female Ends, ASTM A105, NACE + HIC, HVGA30A201EH1M106AMB 1
914

5
MaxC.E., CL 1500, SW/ TE, Manufacturer
CONT.EN
08 TAL-WSA-PNG-ISO-1AFL062502 1"-WSA-1AFL062501-01-C Standard, HW TRIM: N 12

200
E 3733122
N 1928187

<J> 1
EL +116644
6 1 Spectacle Blind (Figure 8), ASTM A516 Gr. 70, HMF8SFA4011B0AD080 1
07 NACE + HIC,Max C.E., CL 150, FF, B16.48
33
INSUL 05
UNDEFINED
33
7
24 45.6° 8
1014
90° 1"-WSA-1AFL062501-01-B
200

914
848
26 06 3
04
50

<K> 1

22 1X3/4"NPD
5

22 14
STEM UP CLASS:
+1

4
48

INSUL 95 A6JH1F
3
353

EL +115764 H CLASS:
0

03 A21F
1
25
36
1
13
STEM WEST
+150
419

4X1"NPD <A> 1
1"NPD
<L> 1

CONT.EN
1"-WSA-1AFL062501-01-F TAL-WSA-PNG-ISO-1AFL068003
E 3733384
N 1928224 27
EL +115411
CONT.EN
TAL-WSA-PNG-ISO-1FG059002
E 3732905
1"-WSA-1AFL062501-01-A F9 N 1928187
EL +115664
0
12
54
28 CUT PIECE SIZE LENGTH END PREP-1 END PREP-2

A 1" 483 BEVEL SQ.CUT


B 1" 859 SQ.CUT SQ.CUT
24 C 1" 214 SQ.CUT SQ.CUT
D 1" 101 SQ.CUT SQ.CUT
25 E 1" 100 SQ.CUT SQ.CUT
F 1" 100 SQ.CUT SQ.CUT

353
G 1" 100 SQ.CUT SQ.CUT
1 H 1" 150 SQ.CUT SQ.CUT
36 I 1" 150 SQ.CUT SQ.CUT
1 J 1" 200 SQ.CUT SQ.CUT
K 1" 200 SQ.CUT SQ.CUT
- - - - - -
FECHA DE EXTRACCION: 28/01/20

- - - - - -

00 EMISION PARA CONSTRUCCION 24/01/2020 GV ALD JCC


REV. DESCRIPCIÓN FECHA ELAB. REV. APR.

PROYECTO MODERNIZACIÓN REFINERÍA TALARA


UNIDADES AUXILIARES Y TRABAJOS COMPLEMENTARIOS

FIELD FIT FIELD SHOP SOCKET SCREWED PIPE STEAM INSULATEDSHT

FFW
WELD WELD WELD WELD JOINT SUPPORT TRACING PIPE 1 OF 1
INGENIERÍA DE DETALLE
Este Documento contiene NOTAS GENERALES ESPECIFICACIÓN DE SOLDADURA ESPECIFICACIÓN DE AISLAMIENTO PLANOS DE REFERENCIA CONDICIONES PRESIÓN TEMPERATURA
información privada y no PLANO
puede ser duplicado, 1. VERIFICAR Y AJUSTAR MEDIDAS EN OBRA. TAL-GEN-PNG-ESP-0008 TAL-GEN-PNG-SPE-0007 DTI APLICADO DISEÑO 3.5 Kg/cm2 250° C
modificado o divulgado a
terceros sin el
2. TODAS LAS MEDIDAS ESTÁN EN MILÍMETROS, SALVO SE INDIQUE LO CONTRARIO.
3. PARA NIVEL DEL TERRENO VER PLANO DE PLANTA DE LA ZONA. TRATAMIENTO TÉRMICO TIPO H ESPESOR 38 TAL-WSA-PRO-PID-0029 OPERACIÓN 0.15 Kg/cm2 38 ° C
WSA - PLANTA DE ÁCIDO SULFÚRICO
consentimiento escrito de 4. EL NIVEL +0.00 CORRESPONDE AL NIVEL 102.926 m.
5. LAS DIMENSIONES DE LOS ELEMENTOS DE TUBERÍA DE LA ESPECIFICACIÓN A0R1F SERÁN DEFINIDAS CUANDO SE PRESIÓN DE
ISOMETRICOS - ALIVIO DE GASES ÁCIDOS A ANTORCHA
COBRA SCL. La única Si ESPECIFICACIÓN DE PINTURA PLANO DE VISTAS DE TUBERÍAS 5.6 Kg/cm2 TIPO HIDRÁULICA
copia Controlada de este SELECCIONE EL PROVEEDOR.
6. LOS CODOS DE LA ESPECIFICACIÓN A0R1F SON DE RADIO LARGO.
PRUEBA
1"-AFL-WSA-02901-A6JH1F-T
Documento está en el 7. TODAS LAS CONEXIONES DE BRIDA DE LA ESPECIFICACIÓN A0R1F DEBEN ESTAR PROVISTAS DE "SPLASH GUARDS". ENSAYOS NO DESTRUCTIVOS TAL-GEN-MET-SPE-0001 / 2Uuu TAL-WSA-PNG-LAY-0101 DENOMINACIÓN COMPLETA DE LÍNEA
Sistema Informático de NÚMERO DE PLANO REV.
Gestión Documental de LÍQUIDOS 100% RX No TRACEADO DOC. ANALISIS FLEXIBILIDAD 1"-AFL-WSA-02901-A6JH1F-T
COBRA SCL.
INSPECCIÓN VISUAL Si FLUIDO - TIPO
TAL-WSA-PNG-ISO-1AFL062501 00
T NO APLICA

TAL-WSA-PNG-ISO-1AFL062501_00_A01_00