Documentos de Académico
Documentos de Profesional
Documentos de Cultura
CV
TABLERO "R"
PROPIETARIO (A)
SERVICIO COMERCIAL
0.90
GARIS S.A DE C.V
SITE
1.00
DIRECCION
2.12 T-21mm p.g.g CARR. TOL-NAUCALPAN KM. 4.5
2-10awg
1-10 vtfa
1-10 dtf
NAVE D C.P. 50200 TOLUCA, EDO. DE
1.00 MEXICO
CROQUIZ DE LOCALIZACION:
2.40 SAN NICOLAS TOLENTINO
MA
RI
AN
O
MA
TA
MO
RO
S N
OC
1.00
EM
T
BL
UH
VD.
UA
AE
AC
RO
PU
ILL
N ER
AV
PA TO
AL
JO
UC
NA
VIE
2.40 CENTRAL DE ABASTO DE TOLUCA
AL
A
NO
ER
MI
ED
CA
.F
RR
CA
SANTA CRUZ OTZACATIPAN
VILLA CHARRA
1.00
BARRIO
LA CRUZ
OC
EM
T
LO
UH
IL
RT
UA
BARRIO
2.40 PO
AC
LA LOMA
P EZ
ILL
MAGDALENA
LO
AV
TABLA DE EQUIVALENCIAS
JO
TABLA DE REDUCION BUSHING
VIE
NO
MI
CLAVE DESCRIPCION
CA
TUBERIA CABLE
1.00 R-61 REDUCCIN BUSHING DE 53 A 16 mm. Ø, CAT. RE61
MCA. CROUSE HINDS DOMEX. MEDIDA MEDIDA CALIBRE CALIBRE
R-51 REDUCCIN BUSHING DE 41 A 16 mm. Ø, CAT. RE51 COMERCIAL NORMA COMERCIAL NORMA
MCA. CROUSE HINDS DOMEX.
13 mm (1/2") 16 mm 14 AWG 2.082 mm2
PROYECTO : LOCAL COMERCIAL, BODEGAS
R-41 REDUCCIN BUSHING DE 35 A 16 mm. Ø, CAT. RE41
19 mm (3/4") 21 mm 12 AWG 3.307 mm2 ( NAVE D)
MCA. CROUSE HINDS DOMEX.
2.50 R-31 REDUCCIN BUSHING DE 27 A 16 mm. Ø, CAT. RE31
25 mm ( 1" ) 27 mm 10 AWG 5.260 mm2
32mm (1 1/4") 35 mm 8 AWG 8.367 mm2
MCA. CROUSE HINDS DOMEX.
R-21 38mm (1 1/2") 41 mm 6 AWG 13.300 mm2
REDUCCIN BUSHING DE 21 A 16 mm. Ø, CAT. RE21
T-21mm p.g.g MCA. CROUSE HINDS DOMEX. 51 mm ( 2" ) 53 mm 4 AWG 21.150 mm2
2-10awg R-62 63mm (2 1/2") 63 mm 2 AWG 33.620 mm2
REDUCCIN BUSHING DE 53 A 21 mm. Ø, CAT. RE62
1-10 vtfa MCA. CROUSE HINDS DOMEX. 76 mm ( 3" ) 78 mm 1/0 AWG 53.480 mm2
1.40 1-10 dtf 101 mm ( 4" ) 103 mm 2/0 AWG 67.430 mm2
R-52 REDUCCIN BUSHING DE 41 A 21 mm. Ø, CAT. RE52
MCA. CROUSE HINDS DOMEX. . . 3/0 AWG 85.010 mm2
R-42 REDUCCIN BUSHING DE 35 A 21 mm. Ø, CAT. RE42 4/0 AWG 107.200 mm2
MCA. CROUSE HINDS DOMEX. 250 KCM 126.670 mm2
R-32 REDUCCIN BUSHING DE 27 A 21 mm. Ø, CAT. RE32 300 KCM 152.100 mm2
MCA. CROUSE HINDS DOMEX. 350 KCM 177.340 mm2
R-63 REDUCCIN BUSHING DE 53 A 27 mm. Ø, CAT. RE63 400 KCM 202.680 mm2
3.00 MCA. CROUSE HINDS DOMEX. 500 KCM 253.350 mm2
R-53 REDUCCIN BUSHING DE 41 A 27 mm. Ø, CAT. RE53 600 KCM 304.020 mm2 UNIDAD VERIFICADORA DE INSTALACIONES ELECTRICAS
MCA. CROUSE HINDS DOMEX.
R-43 REDUCCIN BUSHING DE 35 A 27 mm. Ø, CAT. RE43 (UVIE)
MCA. CROUSE HINDS DOMEX.
R-54 REDUCCIN BUSHING DE 41 A 35 mm. Ø, CAT. RE54
1.00 MCA. CROUSE HINDS DOMEX.
No:_________ NOMBRE:______________________
3.00
T-3
MCA. CROUSE HINDS DOMEX.
CONDULET SERIE OVALADA, 27 mm Ø. CAT. "T-37" L-3
MCA. CROUSE HINDS DOMEX.
CONDULET SERIE OVALADA, 27 mm Ø. CAT. "LB-37"
1:25
BAJA A
TABLERO "S"
1.20 T-4
MCA. CROUSE HINDS DOMEX.
CONDULET SERIE OVALADA, 35
MCA. CROUSE HINDS DOMEX.
mm Ø. CAT. "T-47" L-4
MCA. CROUSE HINDS DOMEX.
CONDULET SERIE OVALADA, 35
MCA. CROUSE HINDS DOMEX.
mm Ø. CAT. "LB-47"
ACOT. IE-ACRS-04
SALCHICHONERIA T-5 CONDULET SERIE OVALADA, 41 mm Ø. CAT. "T-57" L-5 CONDULET SERIE OVALADA, 41 mm Ø. CAT. "LB-57"
PISO DE VENTA MCA. CROUSE HINDS DOMEX. MCA. CROUSE HINDS DOMEX.
T-6 CONDULET SERIE OVALADA, 53
MCA. CROUSE HINDS DOMEX.
mm Ø. CAT. "T-67" L-6 CONDULET SERIE OVALADA, 53
MCA. CROUSE HINDS DOMEX.
mm Ø. CAT. "LB-67" mt.
2.50
PROYECTO PLANO
1.00
REGULADOS SALCHICHONERIA
ALIMENTACIÓN A CONTACTOS
1-10 vtfa 2.11
1-10 dtf CONDULET
TIPO "L"
BODEGAS
TIPO "T"
NAVE "D"
0.90
PROYECTO
CONDULET
2.44 TIPO "T"
REDUCCION REDUCCION CONDULET
3.72 REQUERIDA REQUERIDA TIPO "T"
CONDULET
TIPO "L"
7.38 DETALLE
DETALLES DE ARREGLO PARA CONEXION
EN CRUCE DE TUBERIAS
2.63 ELEVADOR