P N M K J H G F D C B
4132-PLG-10"-C512B-046 270
PLANT 4132-PLG-12"-J512U-033 530 270 4132-PLG-12"-J512U-034
NORTH 1850 3230 1170 710 5800 6510 4530 4530 13020 4930 1850
635
5 12580 N
10"-V207
1300
635 D-4132-PI-DWG-50010
2105
4132-PLG-3"-C512B-047 1 I
315
4132-PA-3"-C512B-722 4132-PLG-8"-C512U-070
490 1
Path: \\golder.gds\complexdata\Office\Lima\CLIENT\Boroo_Pte_Ltd\Lagunas_Norte\99_PROJECTS\21466447_CMOP\02_PRODUCTION\DWG\PROD_DRAWINGS\03_ING_DETALLE\03_PIPE\ | File Name: 21466447-D-4132-PI-DWG-50004.dwg | Last Edited By: jmerino Date: 2022-12-05 Time:12:16:43 PM | Printed By: JMerino Date: 2022-12-05 Time:12:22:42 PM
D-4132-PI-DWG-50011
3255
4132-PA-4"-C512B-708
250
1325
1405
4132-PTS-8"-J512U-134 4132-PA-4"-C512B-733
4132-PA-2"-C512B-720 4132-PLG-8"-C512U-069
4132-PA-2"-C512B-719 SUBE ℄ 4132-CVB145
570 4132-PA-3"-C512B-746 400 1 465
4132-PTS-10"-J512U-117 4132-PLG-8"-C512U-053 4132-PLG-3"-C512B-047 600 600 FILTER DISCHARGE FEEDER N°4
380 400 1
4132-CVB125 ℄ 4132-PA-3"-C512B-722 4132-PTS-10"-J512U-128 595
4132-PA-3"-C512B-743 FILTER DISCHARGE FEEDER N°1 4132-PLG-3"-C512B-063
1515
SUBE
1325
4132-PLG-10"-C512U-052
1 4132-PA-4"-C512B-721 4132-PTS-8"-J512U-137
4132-PTS-8"-J512U-134 490
3085
1
4132-PA-4"-C512B-714 315
4132-PLG-8"-C512U-054 4132-WRR-1 1/2"-C512B-531 4132-PA-3"-C512B-734
4132-PA-1"-C512B-753 4132-PLG-3"-C512B-063
4132-PLG-10"-C512B-048 3"-V208 935
4132-PLG-10"-C512U-068
3405
2105
120 4132-WRR-1 1/2"-C512B-534
4132-PLG-10"-C512B-062
625
3255
4132-PA-4"-C512B-710
1 250
1325
1335
4132-PTS-8"-J512U-135
1
4132-CVB130 ℄ 4132-PA-4"-C512B-737
4132-PA-2"-C512B-724 FILTER DISCHARGE FEEDER N°2 4132-PLG-8"-C512U-072
600
570
4132-PTS-10"-J512U-118
4132-PA-2"-C512B-723
4132-PLG-3"-C512B-049 SUBE
℄ 4132-CVB150 4132-PA-3"-C512B-747 4132-PTS-10"-J512U-129
560
600 FILTER DISCHARGE FEEDER N°5
360 570
4132-PA-3"-C512B-726 4132-PA-2"-C512B-735
4132-PA-3"-C512B-744
4132-PA-2"-C512B-736
1535
4132-PLG-8"-C512U-056 SUBE
1325
4132-PA-4"-C512B-725
4132-PLG-10"-C512U-055 4132-PLG-3"-C512B-065 3"-V208 4132-PTS-8"-J512U-138 490
3085
4132-PA-4"-C512B-716 315
4132-WRR-1 1/2"-C512B-532
4132-PLG-8"-C512U-057 4132-PA-3"-C512B-738
4132-PA-1"-C512B-755
4132-PLG-10"-C512B-050 935
190 HS3-07 4132-PLG-10"-C512U-071
3405
3"-V208
HS3-22 11940 365
7 5650
10"-V207 140 395 420
250 10"-V207
625 4132-PLG-3"-C512B-065
2105
120 4132-PLG-10"-C512B-064
4132-PLG-3"-C512B-051 10
315 345
4132-PA-3"-C512B-730 4132-PA-1"-C512B-761 4132-WRR-1 1/2"-C512B-535 4132-PLG-8"-C512U-076
490 250
3255
4132-PA-4"-C512B-712
4132-PTS-8"-J512U-136
1280
1325
4132-PA-4"-C512B-741
4132-PA-2"-C512B-728 4132-PA-3"-C512B-748
600
570 4132-PTS-10"-J512U-119
4132-PA-2"-C512B-727 4132-CVB135 ℄ 4132-PLG-3"-C512B-051 SUBE ℄ 4132-CVB155 4132-PA-3"-C512B-748 615
FILTER DISCHARGE FEEDER N°1 600
30 FILTER DISCHARGE FEEDER N°6
4132-PA-3"-C512B-730 4132-PTS-10"-J512U-130 570
4132-PA-3"-C512B-745 4132-PA-2"-C512B-739
4132-PA-4"-C512B-729 4132-PLG-8"-C512U-059 4132-PA-2"-C512B-740
SUBE
1515
1325
4132-PLG-10"-C512U-058 4132-PLG-3"-C512B-067 3"-V208
4132-PTS-8"-J512U-139
3085
490
4132-WRR-1 1/2"-C512B-533 4132-PA-4"-C512B-718
4132-PLG-8"-C512U-060 315
4132-PA-3"-C512B-742
2105
4132-PA-1"-C512B-757
1300
4132-PLG-10"-C512U-074
HS3-12 HS3-27
IF THIS MEASUREMENT DOES NOT MATCH WHAT IS SHOWN, THE SHEET SIZE HAS BEEN MODIFIED FROM: ISO A1
8 4132-PLG-3"-C512B-067
10"-V207
1805 6440 5050 6045 4800 4265 6510 5640 870 1120 3240 1840
REF REF 4132-PA-1"-C512B-763 4132-WRR-1 1/2"-C512B-536
120 345 580
140 395 H
G
BOROO - CMOP
D-4132-PI-DWG-50009 AREA 3 - CIL RESIDUE - FILTERING AREA - PIPING ARRANGEMENT
Stamps to Create - 2ND FLOOR T.O.S. 4097.072 D – INFORMATION ONLY ®
D-4132-PI-DWG-50010
Authorization to proceed does not relieve Contractor/Supplier of its responsibility
or liability under the Contract.
Reviewed by: J. Nieto
SCALE 1/75 /
GENERAL NOTES NOTAS GENERALES
1. IT IS THE RESPONSIBILITY OF THE USER OF THIS DRAWING TO ENSURE THE USE OF THE
LEGEND
MOST CURRENT REVISION.
2. SHOULD A DISCREPANCY BETWEEN THE ENGLISH AND SPANISH VERSIONS BE IDENTIFIED, T.O.S. = TOP OF STEEL
THE ENGLISH VERSION SHALL PREVAIL.
3. UNITS IN DRAWING ARE IN THE INTERNATIONAL SYSTEM OF UNITS (SI) UNLESS OTHERWISE
NOTED.
4. ALL DIMENSIONS ARE IN METERS UNLESS OTHERWISE NOTED.
5. ELEVATIONS ARE REFERENCED TO ORTHOMETRIC ALTITUDES (M A.S.L.).
0 2 500 5 000
6. GRID IS REFERENCED TO THE WGS 84 DATUM, UTM COORDINATES SYSTEM, ZONE 17S.
7. THE NUMERICAL SCALES SHOWN IN THE DRAWING APPLY ONLY WHEN IT IS PRINTED IN ISO
A1 SIZE. 1:75 MILLIMETERS
8. HOLD FOR PER PACKAGE OF CERTIFIED INFORMATION FROM THE SUPPLIER
. . CLIENT PROJECT
. .
LAGUNAS NORTE CARBONACEOUS MATERIAL OPTIMIZATION
MINERA BOROO MISQUICHILCA S.A. PROJECT (LNCMOP)
21466447-D-4132-PI-DWG-50000 AREA 3 - CIL RESIDUE - FILTERING AREA - PIPING GENERAL ARRANGEMENT
DETAILED ENGINEERING
21466447-D-0000-PI-DWG-00004 PIPING STANDARD DRAWINGS - CONNECTIONS 4 OF 4 1 2022-12-05 ISSUED FOR CONSTRUCTION DCB JMM CAS DAB CONSULTANT TITLE
GOLDER ASSOCIATES PERÚ S.A.
21466447-D-4132-PI-DWG-50011 AREA 3 - CIL RESIDUE - FILTERING AREA - PIPING ARRANGEMENT - SECTION VIEW 3 OF 3 0 2022-08-11 ISSUED FOR CONSTRUCTION DCB ACM CAS DAB AV. LA PAZ 1049, MIRAFLORES
AREA 3 - CIL RESIDUE - FILTERING AREA
25 mm
21466447-D-4132-PI-DWG-50010 AREA 3 - CIL RESIDUE - FILTERING AREA - PIPING ARRANGEMENT - SECTION VIEW 2 OF 3 B 2022-08-01 ISSUED FOR REVIEW AND COMMENTS VCV ACM CAS DAB
LIMA PIPING ARRANGEMENT - 2ND FLOOR T.O.S 4097.072
PERÚ
21466447-D-4132-PI-DWG-50009 AREA 3 - CIL RESIDUE - FILTERING AREA - PIPING ARRANGEMENT - SECTION VIEW 1 OF 3 A 2022-07-20 ISSUED FOR INTERNAL REVIEW VCV ACM CAS DAB [+51] (1) 610 1700
PROJECT N° DRAWING N° REV.
www.golder.com 1
DRAWING N° REFERENCE DRAWING REV. DATE DESCRIPTION DES. CADD REV. APPD. 21466447 21466447-D-4132-PI-DWG-50004 1