PRODUCT(S) AFFECTED:
STAGE 100/160/100H
(Early production units}
SYMPTOMS:
CONDITION:
Inductor L1 (at output terminal) generates a strong field that gets picked up by the
signal/ground current loop of gain stage at U2a. High levels of gain induce ringing at
approximately 3.6kHz.
REQUIRED ACTION:
Reroute the ground return for U2a to minimize the loop picking up from the output and
L1: