Está en la página 1de 2

G H I J K L M N

L.M. L.C.

ACERA

BP-01
3"
34.00

PISCINA
C.P.
CON REJILLA
Pte.=0.50% 4" 40x40 Pte.=0.50% 4" BP-02
L=15.30m SERIE "R" L=12.30m SERIE "R" C.P.
CON REJILLA 3"
Tendido Enterrado Tendido Enterrado
40x40

SERIE "R"
4"
retiro 3,00m

Pte.=0.3%
REBALSE
BP-01
3"
SALA DE JUEGOS
REBALSE PISCINA
+-0.00
-1.65 -0.35
Pte.=0.3%

REPOSERA LOSA H°A°


REPOSERA BP-02 C.P.

Pte.=0.3%
LOSA
CON REJILLA
40x40
BP-05
3" Pte.=0.50% 4"
L=3.30m SERIE "R" 3"
BP-04

retiro 5,00m
Tendido Enterrado
4"

TV-01
Pte.=0.3%

Pte.=0.3%
4"

BP-03 Prolongar tuberia


de ventilacion 0.50
4" m por encima de
losa de cubierta

-0.15 CS CUARTO DE
BP-06

2"
4"X2" MAQUINAS
Tendido Enterrado C.I.

reti
Pte.=1.50% 4" 40X40 4"
L=5.00m SERIE "R"
34.00

ro 3
,00
2"
BP-05

Pte .50m
-S
+-0.00

m
L=4
+0.30

N
C.I. Tendido Enterrado C.I. BP-04

.=1
40X40 Pte.=1.50% 4" 40X40
CHURRASQUERA 3"

.50
retiro 3,00m

GALERIA
L=6.95m SERIE "R" 4"

Pte 4.45m
L= 1
TV-01

.=0
BP-07

SER
BP-06

Ten

.50
4"

2" - SN
4" 4"

%
IE

did
4"

4" "
2"

"R
GYM

oE
C.I.
SAUNA

SER
40X40

nte
CS 4"
BP-03
4"

3" SERIE "R" SERIE "R"

rrad
4"X2"

IE "
4" "
4"

R
3"

36.
3"

4" 4"
CON SIFON PLANCHADO Prolongar tuberia
CON SIFON de ventilacion 0.50

00
SERIE "R"

2" - SN
Pte.=0.3%

4"

C.I. m por encima de

2" - SN
SN - 2"
Tendido Enterrado

Cámara 40X40 losa de cubierta

2"
Seca
2"

CS LAVANDERIA
LIVING / COMEDOR SOCIAL COCINA CS TV-03-04
SN - 2" 4"X2"
6"X3"
Pte.=1.50%

Con Dispositivo CS 4"


L=8.85m

Anti Espuma 4"X2"

DORM. DE SERV.

Pte.=1.50%
L=7.30m
SN - 2"

BP-07 VESTIDOR

Tendido Enterrado
MASTER SUITE
4" DESPENSA TV-03
4" Pte.=0.3%

SERIE "R"
CÁMARA DE CONEXIÓN CON RED CON SIFON

2" - SN
COCINETA BP-10

4"
DE ALCANTARILLADO PUBLICO C.P. BP-08
CS CON REJILLA
(CHICOTILLO DE CONEXIÓN 4"
4"X2" 40x40
REALIZADO POR SAGUAPAC) 4"

Pte.=0.3%
DEPOSITO
Tendido Enterrado LOSA

3"
TV-04
Pte.=1.50% 4" +-0.00
C.I. L=4.90m SERIE "R" 4"
C.I.
SN - 2"

C.I.
40X40 40X40
2" - SN 2" - SN Pte.=1.50% 3" 40X40
VESTIDOR SUITE 2
L=3.80m SERIE "R" BP-09
Tendido Enterrado 4"
Pte.=0.3%
INGRESO CON SIFON retiro 5,00m
TV-03
RAMPA 20% sube GARAJE
4" SN - 2"

CS -0.45

SERIE "R"
VEST.

4"
ESTAR 4"X2"
ESCRITORIO

Tendido Enterrado
BP-10 INSTALACIÓN SANITARIA Y PLUVIAL
SUITE 1 4" CUBIERTA
2"

BP-08
Esc. 1:100

Pte.=1.50%
TV-04
1 1/2"

2" 2"

L=6.20m
4"

Pte 4.70m
4"

L=1
Pte

.=0
.=0
.3% 4"

Ten

.50
BP-09

%
did
SERIE "R"

Cámara

oE
4"

+-0.00
4"
Seca

SER
nte
rrad

IE "
4" "
ACCESORIOS UTILIZADOS

R
Pte.=1.50% 4"
retiro 5,00m L=12.10m SERIE "R"

Tendido Enterrado
C.I. C.I.
40X40 YEE SIMPLE 4"x4" CODO 90º DE 2"
"

40X40
SERIE "R
4"

(VISTA SUPERIOR) (VISTA SUPERIOR)


Enterrado

SERIE "R"
4"
Tendido Enterrado

-0.45
Tendido

SERIE "R"
Pte.=0.50
L=7.30m

4"
Pte.=0.50%

Tendido Enterrado
L=8.40m

DENOMINACION YEE SIMPLE 4"x4" CODO 90º DE 2"


.3%
Pte.=0.3% Pte.=0.3% Pte.=0

TV-4

Pte.=1.50%
L=5.85m
YEE SIMPLE 4"x3"
+0.00 ACERA 2" DIAMETRO TEE 2"x2"
(en pulgadas)
45.00
CAMARA PLUVIAL CAMARA SIFONADA
CON REJILLA YEE SIMPLE 3"x2"
DE 6" (salida de 3"). CAMARA
SIFONADA DE 6"

CAMARA SIFONADA TEE 3"x2"


CP DE 6" (salida de 2"). (VISTA SUPERIOR)
CAMARA PLUVIAL
SIN REJILLA CAMARA
SIFONADA DE 4"
CAMARA SIFONADA TEE 2"x2"
(VISTA SUPERIOR)
DE 6" (con tapa ciega).
CI
CAMARA DE INSPECCION CAMARA SECA
CAMARA SIFONADA CODO 90º DE 1 1/2"
REJILLA [AGUAS SERVIDAS]
LINEAL DE 4".
2"

CÁMARA DE INSPECCIÓN CODO 90º DE 4"


1 1/2"

CÁMARA PLUVIAL EN JARDINERAS DEJAR


DESNIVEL DE 3CM. CÁMARA PLUVIAL CON DOBLE TAPA CON INSPECCION
CON REJILLA CAMARA SECA. (VISTA SUPERIOR)
SIN REJILLA ESCALA 1:25
2" 2" ESCALA 1:25
CS ESCALA 1:25
PERNOS DE CABEZA PLANA
4"X2" TAPA DE HºAº
0.03m

PERNOS DE
1

TAPA DE HºAº
1/

CABEZA PLANA RELLENO DE MORTERO


REJILLA METALICA
2"

TAPA DE H°A°
DE CAL Y ARENA
1 1/2"
O
D
A
R

6 16/08/19 DISEÑO Y CALCULO: PROPIETARIO:


R

2"
TE

ENLUCIDO DE CEMENTO
EN

TUBERIA DE 4" CONTRATAPA


5 21/05/19
ING. LUIS FEDERICO FERRUFINO CABRERA CARLOS VALVERDE DE LOS RIOS
O

"
ID

MAMPOSTERIA DE DE HºAº
"N 4 22/03/19
D

GLORIA EDITH GONZALEZ ARDUZ


H = 0,25m (minimo)

LADRILLO ADOBITO
N

IE
TE

ENTRADA
SERIE "N"

R SALIDA TUBERIA DE 4"


SE ENTRADA SOPORTE
3 15/03/19 FIRMA Y SELLO DEL RESPONSABLE TÉCNICO:
MAMPOSTERIA DE SALIDA 2 UBICACION:
LADRILLO ADOBITO ENLUCIDO DE
MAMPOSTERIA 1 PLANOS FINALIZADOS 100% - PLANOS PARA APROBACIÓN 17/01/2022
ENLUCIDO DE
CEMENTO
DE LADRILLO PORONGO - URUBO - U.P.U. URB. COLINAS DEL
4" 4" CEMENTO MEDIA CAÑA ADOBITO REV. DESCRIPCION FECHA
URUBO S1-ZR1; MANZANA: 08; LOTE:01
2"

LOSA DE H°A°
SERIE "R" 0.40m
0.40m LOSA DE HºAº CAD. Arq.Nicole Hennners Chavarria REV. Ing. L. Federico Ferrufino C. APROB. Ing. L. Federico Ferrufino C.
0.40m
LOSA DE HºSº
DETALLE SANITARIO LOGOTIPO DE EMPRESA: PROYECTO:
DE BAÑO TIPO
Esc. 1:30
VIVIENDA UNIFAMILIAR

AGUA CALIENTE TITULO DE LAMINA:


AGUA FRIA
INSTALACIÓN SANITARIA Y PLUVIAL
VENTILACION SANITARIA

AGUAS PLUVIALES
Proyectos y Ejecuciones de Sistemas Hidrosanitarios y de Combate a Incendio
instacom@cotas.com.bo
PLANTA SÓTANO
AGUAS SERVIDAS Santa Cruz - Bolivia ESCALA: INDICADA FECHA: 17 / 01 / 2022 CODIGO: 853PH

G H I J K L M N
G H I J K L M N
L.M. L.C.

ESQUEMA ISOMÉTRICO DE SISTEMA


DE PRESURIZACIÓN DE AGUA POTABLE
ACERA FoGo 1"
PRESURIZACION DEL SISTEMA DE CALENTADOR
MANÓMETRO
AGUA POTABLE DE PISCINA
SALA DE
B1

1" - F°G°
SUBE MÁQUINAS
1/2" 34.00 VA A
02 BOMBAS SCALA IDENTICAS PRESURIZADORAS 1"

FoGo
DE VELOCIDAD VARIABLE Y PRESION CONSTANTE
GRIFO
DISTRIBUCIÓN MANÓMETRO (Nombres: B1 y B2 ). TANQUE PLAXBURG

1"

1"
1/2" INTERNA 1" CARACTERISTICAS:
Fo Q = 2.5 m3/h _ _ _ H = 36 m.c.a. VOLUMEN= 1.500 LITROS
Go ANCHO= 1.15m B2
Pot. Est.= 1.0 HP (TRIFÁSICA) ALTO= 1.25m 1"

FoGo
1"

V.R. LL.P.
LARGO= 1.60m
18.40m 3/4" PVC - E40
----------------------------------------------------------------------------- DESAGUE

LL.P.
NOTA:

1"
TENDIDO ENTERRADO 1 1/2"

1" - F°G°
En caso de No Comprar Bombas de Velocidad Variable

FoGo
LL

1"
retiro 3,00m .P. se deberá adicionar 01 Hidrotanque de 100 L y 1"

LL.P.

1"
presostatos para el encendido y apagado.

U.P.
1"

3,17m
B1 FoGo 1"

1 1/2"
EQUIPOS DE

U.P. V.R.

1" - F°G°
TEN
PISCINA

1"
6.70
REBALSE REJILLA DE
3/4"

DID
2" FONDO Sube para prueba periódica de

m
.
L.P

OE
presurización de agua potable
DISPOSITIVO O L B2

NTE
2" 2" SALA DE JUEGOS DEPOSITO
MANGUERA DE

1 1/2" x 1/2"

1 1/2" x 1/2"
RETORNO

RETORNO
DE SALMUERA

3/4"
3/4"

RR
REBALSE PISCINA
2"
ASPIRACIÓN 1"

AD
+-0.00

1 1/2" x 1/2"

PVC
1 1/2" x 1/2"
Fo

RETORNO

RETORNO
-1.65 -0.35

O
Go 3/4"
.P. VA A DISTRIBUCIÓN

- E4
LL INTERNA 1"

0
1" FILTRO DE

FoGo
REPOSERA ABLANDADOR
REPOSERA 1" DE AGUA CARTUCHO 10micras
1 1/2" 1 1/2" VÁLVULAS DE
2" 1" PIE CON CRIBA 1" ENTRADA DE AGUA AL TANQUE
BAJO VIENE DE SAGUAPAC.

2 1/2" PVC - E40

2 1/2" PVC - E40


(ENTRA EN SCH40 Y EN SALA DE

TENDIDO ENTERRADO

3/4"
1"

2" PVC - E40


Fo

TENDIDO ENTERRADO

TENDIDO ENTERRADO

3/4"
Go FLOTADOR SUBE MÁQUINAS SE LLEVA EN FºGº) 1"
3/4" 3/4" 3/4" 3/4"
MECÁNICO 3/4"
1" FILTRO DE PLANTA BAJA

TENDIDO ENTERRADO
CARTUCHO 50micras
SALA DE MÁQUINAS Y

3/4" PVC - E40


5.30m
FoGo 3/4" FoGo 3/4"
TANQUE BAJO

4.45m
6.75m
TENDIDO ENTERRADO
ESC. 1:25
1/2"
15.05m 2 1/2" PVC - E40
-0.15 CUARTO DE
3,19m
MAQUINAS

1/2"
15.10m 2 1/2" PVC - E40
SUBE
34.00

1"- PºPº - 19.35m BAJA 1/2" 3/4" VÁLVULAS DE


TENDIDO ENTERRADO Y SUBE TENDIDO PIE CON CRIBA
+0.30 +-0.00 1" ENTERRADO 1"
CHURRASQUERA 3/4"
SUBE
TENDIDO ENTERRADO

3/4" PRESURIZACION DEL SISTEMA

3/4"- PºPº - 3.10m


retiro 3,00m

1"- PºPº - 4.80m

GALERIA

1"- PºPº - 3.20m


EMPOTRADO MURO BAJA 3/4" TANQUE PLAXBURG CARACTERISTICAS DE AGUA POTABLE
1/2"- PºPº VOLUMEN= 1.500 LITROS
NOTA.-

Tendido Por
Cielo Falso
ANCHO= 1.15m
02 BOMBAS DE PRESURIZACIÓN DE VELOCIDAD
1/2"

1/2"- PºPº
1/2"

ALTO= 1.25m · EL TABLERO ELÉCTRICO ES


GYM 1/2" GRIFO LARGO= 1.60m VARIABLE Y PRESIÓN CONSTANTE.
1/2"
SAUNA BAJAN
RESPONSABILIDAD DEL ENCARGADO DEL
1/2"
BAJA
PROYECTO ELÉCTRICO Y DEBERÁ CONTAR 01 Bomba en funcionamiento y 01 en Stand - By
1/2" (Nombres: B1 y B2 ).
1/2"
CON TODAS LAS PROTECCIONES PARA LOS
1/2"- PºPº DETALLE DEL SISTEMA DE
1/2"

1/2" 1/2"- PºPº


SUBEN EQUIPOS, COMO SON LOS GUARDAMOTORES

3 6.
3/4" FILTRADO DE AGUA POTABLE Q 01 = 3.1m3/hora _ _ _ H 01 = 18 m.c.a.
1/2" Y CON BOTONERAS QUE TENGAN LA OPCIÓN

1"

1/2"

1/2"
3/4"
PLANCHADO 1/2"
ESC : 1:25 Q 02 = 3.1m3/hora _ _ _ H 02 = 18 m.c.a.

00
DE DISPONER DE ESTADO MANUAL Y

1/2"
Pot. Est.= 0.75 HP (TRIFÁSICA)

3/4"
BAJA

1/2"
SUBE FILTRO DE AUTOMÁTICO.
3/4"- PºPº

1/2" VIENE DE
1/2" LAVANDERIA 1/2" CARTUCHO DEPOSITO
GRIFO BAJAN 1/2"
3/4"- PºPº

LIVING / COMEDOR SOCIAL 1"- PºPº 3/4"- PºPº 3/4"- PºPº ACOMETIDA 10micras DE SALMUERA
1/2" 3/4" COCINA
1"
1/2"

1/2"

BAJAN 3/4"- PºPº


BAJAN
1/2" 3/4" .P.
3/4"- PºPº 3/4"
1" LL

Tendido Por Cielo Falso


3/4" 3/4"- PºPº

3/4"- PºPº - 3.05m


1/2" DORM. DE SERV. ABLANDADOR
3/4"- PºPº

Tendido Por Cielo Falso DE RESINA


Tendido Por
Cielo Falso

1"

3/4"- PºPº - 3.30m


VESTIDOR
3/4"- PºPº

LL .P.

17.50m

TEND
MASTER SUITE .P.
DESPENSA LL .P.
SUBE LL
3/4"

FILTRO DE

IDO E
3/4" 1" CARTUCHO
LL
.P. 50micras
3/4"- PºPº BAJAN

NTER
1"

3/4" P
BAJA 1/2" LL
3/4" 3/4" BAJAN COCINETA .P. .P.

RADO
1/2" SISTEMA DE FILTRADO 1" LL

VC -
3/4"
1/2"

1/2"
1/2"

1/2"

3/4"- PºPº - 2.60m


1/2"

E40
DEPOSITO 1"

3/4"- PºPº
Tendido Por
Cielo Falso
1/2" FILTRO DE CARTUCHO LL
.P. .P.
+-0.00 LL
Q = 2.0 m³/h
BAJA Ø mínimo = 0.30 m 1"
VESTIDOR SUITE 2 1/2" VA A TENDIDO DE
PRESIÓN DE TRABAJO = 20 m.c.a.

1/2"
1/2"
PRESURIZACION
Tendido Por Cielo Falso
3/4"- PºPº - 7.85m 1/2"
3/4" PVC - E40

3/4"- PºPº - 7.85m 3/4"- PºPº


3/4"

ABLANDADOR DE RESINA
3/4"

INGRESO BAJA
TENDIDO ENTERRADO

Tendido Por Cielo Falso EMPOTRADO MURO


BAJAN 3/4"
RAMPA 20% sube GARAJE
DETALLE ISOMÉTRICO
3/4" Q = 2.0 m³/h DE BAÑO TIPO

2.80m

2.60m
VEST. -0.45 Ø = 0.30 m (tasa de percolación S/ESC
ESTAR
ESCRITORIO 400 l/min/m²)
3/4"

1/2"
PRESIÓN DE TRABAJO = 20 m.c.a.
12.20m

SUITE 1
1/2"
1/2"

SIMBOLOGÍA
3/4"

3/4"-P°P°

3/4"-P°P°
DE ARTEFACTOS
1/2" L.C.
1/2"

SUBE 1/2"
1/2" D. DUCHA
GRIFO
1/2" 1/2"- PºPº m
.20
+-0.00 EMPOTRADO MURO +2 L. LAVAMANOS
T D.
NP
I. INODORO
1/2"

retiro 5,00m Dh. DUCHA HIGIÉNICA


6.85m 3/4" PVC - E40 29.65m 3/4" PVC - E40
TENDIDO ENTERRADO TENDIDO ENTERRADO m
.40
+0
EMPOTRADO EN MURO T

TEND
+0 NP

4.50m
3/4" PºPº .60
-0.45 1/2" PºPº - 1.25m m NOTA:
NP

ID
T LOS NIVELES INDICADOS EN

O EN
L. "
3/4 ESTE ESQUEMA SON A PARTIR
1/2" 3/4" PºPº - 1.25m DEL PISO TERMINADO (NPT)

3/4"

TERR
3/4" PºPº BAJAN
L.M.

PVC
3/4"

1/2"

1/2"
ADO

1/2"
m
.00

- E40
+1 "
L. T Pº 3/4

3/4" PºPº - 1.55m


EMPOTRADO EN MURO
D. NP
"-
1/2
+0.00 GRIFO ACERA 5m
1/2" 1.2 RO
M U
45.00 ºP
º EN
- P ADO

M
.20
m " R
+0 3/4 OT
P
NP
T
EM
"
1/2
m 1/2
ACOMETIDA DE .20
+0 "-
AGUA POTABLE T Pº
(SAGUAPAC) N P EM Pº
PO
INSTALACIÓN SANITARIA Y PLUVIAL I.
DETALLE EN PLANTA TR
1/2" AD 1.5
PLANTA BAJA DE BAÑO TIPO O
EN 5m
Esc. 1:100 1/2" Dh. ESC : 1:25 MU I.
RO
Dh.

Desagüe Retro-lavado m
.20
de Filtro de Arena +0
1 1/2"

T
DETALLES Filtro de
NP
DE PISCINA Arena
B6
2 1/2"
Agua para llenado
de piscina
EQUIPO DE PISCINA
EQUIPO SUGERIDO: WILO: EMHIL 303 M EQUIPO SUGERIDO: GRUNDFOS: SCALA1 5-25
LL.P. V.R
Viene de BY-PASS
3/4"
Calentador de
piscina B6 = BOMBA CON PRE-FILTRO.
Q = 10 m3 / h _ _ H = 8m.c.a.
LL.P.

LL.P.

Va para Pot.= 0.75 HP (TRIFÁSICA)


6 16/08/19 DISEÑO Y CALCULO: PROPIETARIO:
Calentador de
piscina
1 1/2"
FILTRO DE ARENA
5 21/05/19
ING. LUIS FEDERICO FERRUFINO CABRERA CARLOS VALVERDE DE LOS RIOS
4 22/03/19
1 1/2"
Q = 17.10 m3 / h
Area de filtración = 0.34m2
GLORIA EDITH GONZALEZ ARDUZ
3 15/03/19 FIRMA Y SELLO DEL RESPONSABLE TÉCNICO:
2 1/2"

Velocidad de Filtrado = 50 m3 / m2 / h
2"

Equipo recomendado = VULCANO VC100 2 UBICACION:


2 1/2"

LEYENDAS:
U.P. UNIÓN PATENTE 1 PLANOS FINALIZADOS 100% - PLANOS PARA APROBACIÓN 17/01/2022
V.R. VÁLVULA DE RETENCIÓN
PORONGO - URUBO - U.P.U. URB. COLINAS DEL
REV. DESCRIPCION FECHA
URUBO S1-ZR1; MANZANA: 08; LOTE:01
Viene de manguera

LL.P. LLAVE DE PASO


Rejillas de fondo

de aspiración 2"
PVC E40 - 2 1/2"

CAD. Arq.Nicole Hennners Chavarria REV. Ing. L. Federico Ferrufino C. APROB. Ing. L. Federico Ferrufino C.

Va hacia retornos
LOGOTIPO DE EMPRESA: PROYECTO:
de la piscina 2"

VIVIENDA UNIFAMILIAR

AGUA CALIENTE TITULO DE LAMINA:


AGUA FRIA
INSTALACIÓN SANITARIA Y PLUVIAL
VENTILACION SANITARIA

AGUAS PLUVIALES
Proyectos y Ejecuciones de Sistemas Hidrosanitarios y de Combate a Incendio
instacom@cotas.com.bo
PLANTA SÓTANO
AGUAS SERVIDAS Santa Cruz - Bolivia ESCALA: INDICADA FECHA: 17 / 01 / 2022 CODIGO: 853PH

G H I J K L M N

También podría gustarte