Documentos de Académico
Documentos de Profesional
Documentos de Cultura
Project no:
Author:
Project data
Project name
Project number
Author
Description
Date 05/18/2023
Design code AISC 360-10
Material
Steel A992, A572 Gr.50
Concrete 4000 psi
1 / 26
Project:
Project no:
Author:
Design
Name PB CM-1 X6-Y4
Description
Analysis Stress, strain/ simplified loading
Design code AISC - LRFD 2010
Members
Geometry
2 / 26
Project:
Project no:
Author:
3 / 26
Project:
Project no:
Author:
Cross-sections
Name Material
2 - CM-1(General) A572 Gr.50, A572 Gr.50, A572 Gr.50, A572 Gr.50, A572 Gr.50, A572 Gr.50, A572 Gr.50
6 - Plate 50.8, 400 A572 Gr.50
4 / 26
Project:
Project no:
Author:
Cross-sections
Name Material Drawing
Anchors
Diameter fu Gross area
Name Bolt assembly
[mm] [MPa] [mm2]
1 F1554 Gr.105 1 F1554 Gr.105 25 861.8 507
5 / 26
Project:
Project no:
Author:
Foundation block
Item Value Unit
CB 1
Dimensions 935 x 1170 mm
Depth 1800 mm
Anchor 1 F1554 Gr.105
Anchoring length 1500 mm
Shear force transfer Shear lug
Cross-section of shear lug Plate 50.8, 400
Length of shear lug 180 mm
Check
Summary
Name Value Check status
Analysis 100.0% OK
Plates 0.0 < 5.0% OK
Anchors 11.0 < 100% OK
Welds 0.0 < 100% OK
Concrete block 60.8 < 100% OK
Shear 20.9 < 100% OK
Buckling Not calculated
Plates
Fy Thickness σEd εPl σc,Ed
Name Loads Check status
[MPa] [mm] [MPa] [%] [MPa]
COL-bfl 1 344.7 19.0 LE5 110.5 0.0 0.0 OK
COL-bfl 2 344.7 29.0 LE2 265.6 0.0 0.0 OK
COL-bfl 3 344.7 29.0 LE2 265.3 0.0 0.0 OK
COL-bfl 4 344.7 19.0 LE5 111.0 0.0 0.0 OK
COL-bfl 5 344.7 29.0 LE2 264.8 0.0 0.0 OK
COL-bfl 6 344.7 19.0 LE5 121.5 0.0 0.0 OK
COL-bfl 7 344.7 29.0 LE2 257.8 0.0 0.0 OK
Member 2-bfl 1 344.7 50.8 LE5 52.4 0.0 0.0 OK
BP1 344.7 38.1 LE5 147.3 0.0 0.0 OK
Design data
Fy εlim
Material
[MPa] [%]
A572 Gr.50 344.7 5.0
6 / 26
Project:
Project no:
Author:
7 / 26
Project:
Project no:
Author:
Anchors
Nf ϕNp ϕNsb Utt Uts Utts
Shape Item Loads Status
[kN] [kN] [kN] [%] [%] [%]
A1 LE5 24.9 307.8 87.2 10.6 0.0 2.4 OK
A2 LE5 16.0 307.8 87.2 6.8 0.0 1.1 OK
A3 LE5 25.9 307.8 87.2 11.0 0.0 2.5 OK
A4 LE5 14.6 307.8 87.2 6.2 0.0 1.0 OK
A5 LE5 24.3 307.8 87.2 10.3 0.0 2.3 OK
A6 LE5 15.5 307.8 87.2 6.6 0.0 1.1 OK
A7 LE5 25.3 307.8 87.2 10.7 0.0 2.4 OK
A8 LE5 14.0 307.8 87.2 6.0 0.0 0.9 OK
Design data
ϕNsa ϕVsa
[kN] [kN]
235.4 131.1
8 / 26
Project:
Project no:
Author:
Where:
ϕ = 0.70 – resistance factor
ϕNpn = ϕ ⋅ Ψc,P ⋅ Np =
307.8 kN ≥ Nf =
24.9 kN
Where:
ϕ = 0.70 – resistance factor
Ψc,P = 1.00
– modification factor for concrete condition
Np = 439.8 kN – basic concrete pullout strength for headed anchor:
Abrg = 1993 mm2 – bearing area of the head of stud or anchor bolt
ϕNsb = rc ⋅ Nsbg =
87.2 kN ≥ Nf =
24.9 kN
Where:
rc = 0.50 – reduction factor for anchor close to an edge or multiple anchors with small spacing:
ca2 s
1+ 1+
Abgr = 1993 mm2 – bearing area of the head of stud or anchor bolt
9 / 26
Project:
Project no:
Author:
Where:
ϕ = 0.65 – resistance factor
Ase,V = 391 mm2 – tensile stress area
Where:
Utt = 0.11 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Where:
ϕ = 0.70 – resistance factor
10 / 26
Project:
Project no:
Author:
ϕNpn = ϕ ⋅ Ψc,P ⋅ Np =
307.8 kN ≥ Nf =
16.0 kN
Where:
ϕ = 0.70 – resistance factor
Ψc,P = 1.00
– modification factor for concrete condition
Abrg = 1993 mm2 – bearing area of the head of stud or anchor bolt
ϕNsb = rc ⋅ Nsbg =
87.2 kN ≥ Nf =
16.0 kN
Where:
rc = 0.50 – reduction factor for anchor close to an edge or multiple anchors with small spacing:
ca2 s
1+ 1+
Abgr = 1993 mm2 – bearing area of the head of stud or anchor bolt
Where:
ϕ = 0.65 – resistance factor
Ase,V = 391 mm2 – tensile stress area
11 / 26
Project:
Project no:
Author:
Where:
Utt = 0.07 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Where:
ϕ = 0.70 – resistance factor
ϕNpn = ϕ ⋅ Ψc,P ⋅ Np =
307.8 kN ≥ Nf =
25.9 kN
Where:
ϕ = 0.70 – resistance factor
Ψc,P = 1.00
– modification factor for concrete condition
Abrg = 1993 mm2 – bearing area of the head of stud or anchor bolt
12 / 26
Project:
Project no:
Author:
ϕNsb = rc ⋅ Nsbg =
87.2 kN ≥ Nf =
25.9 kN
Where:
rc = 0.50 – reduction factor for anchor close to an edge or multiple anchors with small spacing:
ca2 s
1+ 1+
Abgr = 1993 mm2 – bearing area of the head of stud or anchor bolt
Where:
ϕ = 0.65 – resistance factor
Where:
Utt = 0.11 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
13 / 26
Project:
Project no:
Author:
Where:
ϕ = 0.70 – resistance factor
ϕNpn = ϕ ⋅ Ψc,P ⋅ Np =
307.8 kN ≥ Nf =
14.6 kN
Where:
ϕ = 0.70 – resistance factor
Ψc,P = 1.00
– modification factor for concrete condition
Abrg = 1993 mm2 – bearing area of the head of stud or anchor bolt
ϕNsb = rc ⋅ Nsbg =
87.2 kN ≥ Nf =
14.6 kN
Where:
rc = 0.50 – reduction factor for anchor close to an edge or multiple anchors with small spacing:
ca2 s
1+ 1+
Abgr = 1993 mm2 – bearing area of the head of stud or anchor bolt
14 / 26
Project:
Project no:
Author:
Where:
ϕ = 0.65 – resistance factor
Where:
Utt = 0.06 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Where:
ϕ = 0.70 – resistance factor
15 / 26
Project:
Project no:
Author:
ϕNpn = ϕ ⋅ Ψc,P ⋅ Np =
307.8 kN ≥ Nf =
24.3 kN
Where:
ϕ = 0.70 – resistance factor
Ψc,P = 1.00
– modification factor for concrete condition
Np = 439.8 kN – basic concrete pullout strength for headed anchor:
Abrg = 1993 mm2 – bearing area of the head of stud or anchor bolt
ϕNsb = rc ⋅ Nsbg =
87.2 kN ≥ Nf =
24.3 kN
Where:
rc = 0.50 – reduction factor for anchor close to an edge or multiple anchors with small spacing:
ca2 s
1+ 1+
Abgr = 1993 mm2 – bearing area of the head of stud or anchor bolt
Where:
ϕ = 0.65 – resistance factor
16 / 26
Project:
Project no:
Author:
Where:
Utt = 0.10 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Where:
ϕ = 0.70 – resistance factor
ϕNpn = ϕ ⋅ Ψc,P ⋅ Np =
307.8 kN ≥ Nf =
15.5 kN
Where:
ϕ = 0.70 – resistance factor
Ψc,P = 1.00
– modification factor for concrete condition
Abrg = 1993 mm2 – bearing area of the head of stud or anchor bolt
17 / 26
Project:
Project no:
Author:
ϕNsb = rc ⋅ Nsbg =
87.2 kN ≥ Nf =
15.5 kN
Where:
rc = 0.50 – reduction factor for anchor close to an edge or multiple anchors with small spacing:
ca2 s
1+ 1+
Abgr = 1993 mm2 – bearing area of the head of stud or anchor bolt
Where:
ϕ = 0.65 – resistance factor
Where:
Utt = 0.07 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
18 / 26
Project:
Project no:
Author:
Where:
ϕ = 0.70 – resistance factor
ϕNpn = ϕ ⋅ Ψc,P ⋅ Np =
307.8 kN ≥ Nf =
25.3 kN
Where:
ϕ = 0.70 – resistance factor
Ψc,P = 1.00
– modification factor for concrete condition
Np = 439.8 kN – basic concrete pullout strength for headed anchor:
Abrg = 1993 mm2 – bearing area of the head of stud or anchor bolt
ϕNsb = rc ⋅ Nsbg =
87.2 kN ≥ Nf =
25.3 kN
Where:
rc = 0.50 – reduction factor for anchor close to an edge or multiple anchors with small spacing:
ca2 s
1+ 1+
Abgr = 1993 mm2 – bearing area of the head of stud or anchor bolt
19 / 26
Project:
Project no:
Author:
Where:
ϕ = 0.65 – resistance factor
Where:
Utt = 0.11 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Where:
ϕ = 0.70 – resistance factor
20 / 26
Project:
Project no:
Author:
ϕNpn = ϕ ⋅ Ψc,P ⋅ Np =
307.8 kN ≥ Nf =
14.0 kN
Where:
ϕ = 0.70 – resistance factor
Ψc,P = 1.00
– modification factor for concrete condition
Abrg = 1993 mm2 – bearing area of the head of stud or anchor bolt
ϕNsb = rc ⋅ Nsbg =
87.2 kN ≥ Nf =
14.0 kN
Where:
rc = 0.50 – reduction factor for anchor close to an edge or multiple anchors with small spacing:
ca2 s
1+ 1+
Abgr = 1993 mm2 – bearing area of the head of stud or anchor bolt
Where:
ϕ = 0.65 – resistance factor
21 / 26
Project:
Project no:
Author:
Where:
Utt = 0.06 – maximum ratio of factored tensile force and tensile resistance determined from all appropriate failure
modes
Uts = 0.00 – maximum ratio of factored shear force and shear resistance determined from all appropriate failure
modes
Welds
tw w L Lc Fn ϕRn Ut
Item Edge Xu Loads Status
[mm] [mm] [mm] [mm] [kN] [kN] [%]
BP1 COL-bfl 1 E70xx - - 442 - - - - - OK
BP1 COL-bfl 2 E70xx - - 290 - - - - - OK
BP1 COL-bfl 3 E70xx - - 290 - - - - - OK
BP1 COL-bfl 4 E70xx - - 212 - - - - - OK
BP1 COL-bfl 5 E70xx - - 290 - - - - - OK
BP1 COL-bfl 6 E70xx - - 212 - - - - - OK
BP1 COL-bfl 7 E70xx - - 290 - - - - - OK
BP1 Member 2-bfl 1 E70xx - - 400 - - - - - OK
Butt welds are not checked. Their resistance is assumed to be the same as that of the welded member.
Concrete block
A1 A2 σ Ut
Item Loads Status
[mm2] [mm2] [MPa] [%]
CB 1 LE5 594901 632122 9.6 60.8 OK
ϕc fp,max =
15.7 MPa ≥ σ= 9.6 MPa
Where:
fp,max = 24.2 MPa – concrete block design bearing strength:
≤ 1.7 ⋅ fc′ , where:
22 / 26
Project:
Project no:
Author:
Where:
ϕ = 0.7 – resistance factor for bearing of bolts on steel
fc′
= 27.6 MPa – concrete compressive strength
A1 =
72289 mm2 – projected area of the embedded area of the shear lug in the direction of the force excluding the
portion of the lug in contact with the grout above concrete member
Kc = 1.60
– confinement coefficient
Ny = 2264.3 kN
– yield strength of tensioned anchors
Ny = n ⋅ Ase ⋅ Fy , where:
Where:
ϕ = 0.85 – steel embedment material resistance factor for reinforcement
Ψα,V = 2. – modification factor for shear lug loaded at an angle with the concrete edge
1
Ψα,V =
(cos αV )2 +(0.5⋅sin αV )2
, where:
αV = 87.9 ° – angle between direction of shear force and direction perpendicular to concrete edge
Avc = 183322 mm2 – effective stress area defined by projecting a 45o plane from the bearing edges of the shear lug to
the free surface in the direction of the shear load. The bearing area of the shear lug is excluded
from the projected area.
fc′ = 27.6 MPa
– concrete compressive strength
Buckling
Buckling analysis was not calculated.
23 / 26
Project:
Project no:
Author:
Bill of material
Manufacturing operations
Plates Welds Length
Name Shape Nr. Bolts Nr.
[mm] [mm] [mm]
Welds
Throat thickness Leg size Length
Type Material
[mm] [mm] [mm]
Butt E70xx - - 865.0
Butt E70xx - - 1160.0
Butt E70xx - - 400.0
Anchors
Length Drill length
Name Count
[mm] [mm]
1 F1554 Gr.105 1538 1500 8
24 / 26
Project:
Project no:
Author:
Symbol explanation
Symbol Symbol explanation
εPl Strain
fy Yield strength
εlim Limit of plastic strain
Nf Tension force
ϕNp Pullout strength in tension – ACI 318-14 – 17.4.3
ϕNsb Concrete side-face blowout strength in tension – ACI 318-14 – 17.4.4
Ut Utilization
Uts Utilization in shear
Utts Interaction of tension and shear EN 1993-1-8 table 3.4
ϕNsa Steel strength in tension – ACI 318-14 – 17.4.1
φVsa Steel strength in shear – ACI 318-14 – 17.5.1
Th Throat thickness of weld
Ls Leg size of weld
L Length of weld
Lc Length of critical weld element
Fn Force in weld critical element
Rn/Ωw Weld resistance AISC 360-16 J2.4
A1 Loaded area
A2 Supporting area
σ Average stress in concrete
V Resultant of bolt shear forces Vy and Vz in shear planes
Pbr Concrete block bearing capacity
Vcb Concrete cone breakout resistance
25 / 26
Project:
Project no:
Author:
Code settings
Item Value Unit Reference
Friction coefficient - concrete 0.40 - ACI 349 – B.6.1.4
Friction coefficient in slip-resistance 0.30 - AISC 360-10 J3.8
Limit plastic strain 0.05 -
Detailing No
Distance between bolts [d] 2.66 - AISC 360-10 – J3.3
Distance between bolts and edge [d] 1.25 - AISC 360-10 – J.3.4
Concrete breakout resistance check None
Base metal capacity check at weld fusion face No AISC 360-10: J2-2
Deformation at bolt hole at service load is design
Yes AISC 360-16: J3.10
consideration
Cracked concrete Yes ACI 318-14 – Chapter 17
Local deformation check No
Local deformation limit 0.03 - CIDECT DG 1, 3 - 1.1
Analysis with large deformations for hollow section
Geometrical nonlinearity (GMNA) Yes
joints
26 / 26