Documentos de Académico
Documentos de Profesional
Documentos de Cultura
R&R Micrometro 25-3-20
R&R Micrometro 25-3-20
COLUMNA 1 2 3 4 5 6 7 8 9 10 11 12 13
OPERADOR A.-DELYA ORTIZ HERNANDEZ B.-ANA ORTIZ MARTINEZ C.RAUL JIMENEZ JUAREZ
MUESTRA 1er. INT. 2do. INT. 3er. INT RANGO 1er. INT. 2do. INT. 3er. INT RANGO 1er. INT. 2do. INT. 3er. INT RANGO Xp.
1 6.16 6.15 6.2 0.01 6.2 6.2 6.2 0.02 6.2 6.2 6.17 0.02 6.16
2 6.17 6.18 6.2 0.01 6.2 6.2 6.2 0.01 6.2 6.2 6.18 0.01 6.18
3 6.18 6.19 6.2 0.02 6.2 6.2 6.2 0.02 6.2 6.2 6.20 0.00 6.20
4 6.72 6.73 6.7 0.03 6.7 6.7 6.7 0.01 6.7 6.7 6.70 0.04 6.70
5 6.40 6.42 6.4 0.02 6.4 6.4 6.4 0.00 6.4 6.4 6.40 0.02 6.41
6 6.11 6.10 6.1 0.01 6.1 6.1 6.1 0.01 6.1 6.1 6.11 0.01 6.11
7 6.11 6.12 6.1 0.01 6.1 6.1 6.1 0.01 6.1 6.1 6.10 0.02 6.11
8 6.75 6.76 6.7 0.02 6.8 6.8 6.8 0.01 6.8 6.8 6.75 0.01 6.75
9 6.25 6.26 6.3 0.01 6.3 6.3 6.3 0.01 6.3 6.3 6.25 0.01 6.26
10 6.20 6.26 6.3 0.06 6.3 6.2 6.3 0.07 6.3 6.3 6.20 0.06 6.24
TOTALES 56.85 56.91 56.88 0.14 56.88 56.87 56.92 0.10 56.84 56.89 56.86 0.14
A1 = 56.85 R. PROM. A = 0.02 B1 = 56.88 R. PROM. B = 0.01 C1 = 56.84 R. PROM. C = 0.02
A2 = 56.91 B2 = 56.87 C2 = 56.89
A3 = 56.88 B3 = 56.92 C3 = 56.86
SUMA A = 170.64 SUMA B = 170.67 SUMA C = 170.59
R. PROM. A = 0.02
UCLR = ( R ) ( D4 )
No. INT. D3 UCLR = 0.014 2.580 * UCLR = 0.03631 No. INT. D4
0-7 0 UCLR = 0.036311 2 3.27
3 2.58
LCLR = ( R ) ( D3 )
LCLR = 0.01 0 * LCLR = 0
LCLR = 0
* LIMITE SUPERIOR DE CONTROL DE LOS RANGOS . CIRCUNSCRIBA AQUELLOS VALORES QUE VAYAN MAS ALLA DE ESTE LIMITE .
IDENTIFIQUE LA CAUSA Y CORRIJALA, SUSTITUYA ESTAS LECTURAS USANDO EL MISMO OPERADOR Y UNIDAD O DESCARTE
LOS VALORES, VUELVA A CALCULAR EL PROMEDIO, EL RANGO Y EL LIMITE SUPERIOR DE CONTROL DE RANGOS .
CRITERIO DE ACEPTACION
ERROR MENOR AL 10% = EL SISTEMA DE MEDICION ES ACEPTADO EN LAS CONDICIONES DE OPERACION ACTUALES.
ERROR DE 10% Y HASTA 30% = EL SISTEMA PUEDE SER ACEPTABLE Y DEPENDE DEL COSTO DEL INSTRUMENTO DE MEDICION,
DE LA IMPORTANCIA DE SU APLICACION Y DEL CONSTO DE REPARACION.
ERROR MAYOR AL 30% = EL SISTEMA ES RECHAZADO POR LOS QUE SE DEBERAN TOMAR ACCIONES INMEDIATAS PARA CORREGIRLO.
NOTAS
Sistema de medicion ACEPTADO BAJO RESERVAS
INT. k1
V.E. = 0.008 2 0.8862 % V.E. = 3.97%
3 0.5908
V.O. = \ 0.000
R&R=\ 0.000
% R&R = 3.97%
R&R= 0.008 % R&R = 4%
R&R = 0.008