Está en la página 1de 6
Eurotest XE MI 3102 BT Serial no: 20290869 Date: 22. 10. 2020 Performed by: Koprivec, Petkovsek Date Placed In Service: Metre! Recommended Cal Interval: 12 months the "Date Placed In Service." Due Date: * The due date may be established (by the customer) by adding the "Recommended Cal Interval” to No.: | Function / Ubat= 7,5 V. I Input Low lit Reading | Uncertainty [High limit 1. Outlook, BAT indication, keys, communication PASS 2. ACvoltageTRMS Un 230 23V 230 Use 230 23V 230 Unee OV ovo change LN Un 230 23V 230 Uee Ov ovo Uype 230 23V 230 237V fcrmer S0Hz 49,8H2z 50,0 OL Hz 50,2 Hz 3. Insulation RISO - _ oe 50 Uiso output 1oMa Sov 82 iv ov iso displayed UisoOut-5V 52 1V_ UisoOut +5V 500V —_Liso output 10Ma s00V $25 BV 600 v Uiso displayed UisoOut-19.V 525 3V UisoOut +19 1000 —_Uiso output 1M 1000V 1050 6v 1200 v Uiso displayed UisoOut-35.V__ 1050 6V UisoOut +35V 4, Insulation INS 50V OMA —0,00MQ_~—0,00 001MM 0,03 M2. 10MQ2 9,47MQ 10,10 -—0,06MQ_—_ 10,53 Ma. 00a 80,0MO__ 104.5 ,0MQ__120,0M0 5. Insulation RISO 500V O.1M2 —0,07M2— 40-001 M2_— 0,13 Ma IMQ 092MQ 4,00 0.01MQ._—1,08 Ma 10M2_ 947M 10,09 0,06MQ_—10,53M2 100Ma = 9sMQ_— 101 10MQ 105 Ma 900MA —_ 810MQ_—_-906 10M 990 Ma. 6. Insulation RISO 1000V IMQ 092MQ2 1,00 O01M2_—«1,08 M2 190M2 1805MQ 194 1LIMQ 19,5 Ma 900M —_720MO_—_—889 10M _999M0 7. Continuity # 200 ma 02 0002 0,00 oon 0030 Riowa 12 0942 1,00 0010 1,06 0 192 18,402 18,93 0112 19,609 Re 192 1760 18,9 O12 2040 R192 1760 18,9 O19 2040 19002 1805-1921 na 1995 2 2 200mA__ PASS 250m, 12 072 40 1900 1802 1910 NI] © + 1 ~ 3 METREL Poe nt) cee SI 1354 HORJUL _hitp:iwww.metrel si Measurement and Regulation Equipment Manufacturers SLOVENIA e-mail: metrel@mettelsi Metrel Certificate of Calibration Practices The Metrel Quality System is certified by BVQI according to Quality standard ISO 9001:2015, Certificate No. SL22466Q. The Metrel hereby certifies that the above instrument was calibrated in accordance with applicable Metrel calibration procedures during the manufacturing process. These processes are ISO 9001 controlled and are designed to assure that the instrument will meet its published specification. The Metrel further certifies that the measurement standards and instruments used during the calibration of this instrument are traceable to the (inter)national standards. The policies and procedures at this facility comply with EN ISO/IEC 17025. Environmental conditions: Temperature: 23 °C + 5 °C Relative humidity: 10 % to 75 % Calibration Procedure: “Name of Model / Type” Uncertainty: The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by coverage factor k = 2, which for a nominal distribution corresponds to a coverage probability of approximately 95%. The standard uncertainty of measurement has been determined in accordance with EA Publication EA-4/02. (Wrote fone Edvard Reven Janko Mole Chief Executive Officer Head of Calibration Laboratory Eurotest XE MI3102 BT — Setaino: 20290869 Date: 22. 10. 2020 Performed by: Koprivec, Petkovéek No.: | Function / Ubat= 7,5 V Input [ Low limit [ Reading | Uncertainty | High limit 3. Phase rotation PASS 10. Contact voltage - RCD U 03a oov ot Ov 10v 10008 — 300V 3,2 02V 345V = 030 03V Os OIV13V : crewetN Tgy=10mA 03 00V—Ot ov 10V = 11, Trip out time - RCDt | gy =100 mA, 183 ms 15,3ms__ 17,8 0,5 ms__21,3 ms, 12. _ Residual current: values, shapes Pass 13. Loop impedance - Zloop 032 0240 0,30 0.012 0,360 12 0.909 1,01 0029 1,100 102 9452 10,00 0,062 10,552 1002 94,50 1020 062 105,50 10002 900 1010 82 102 change LN 0 0,30 0012 0360 14. Loop impedance - Zs red 032 0,192 0,31 0012 0412 12 0850 0,96 0020 1,150 102 = 9,402 10,00 0,062 10,609 1009 94,5 100,0 062 105,50 10002 90021010 82 11009 : change LN 032 0192 0,30 41a 18. Line impedance - Zline 0.240 0,28 0012 0,360 0902 0,98 0022 1,109 945 — 10,00 0,060 10,559 94sQ 1020 062 105,50 9002 1010 11000 change LN 0240 0,28 0.36.0 16. PE retum path resistance - 0,09 0,01 0,180 Rpe RCD 0652 0,72 0,939 9.202 9,79 10,400 9452 10,3 062 105,50 900% 1015 sa 11009 change LN 0,002 0,01 0019 0.180 17. Earth 3w 0,002 0,00 0,019 0,050 0,902 1,00 0012 1,100 9452 — 10,02 0,062 10,550 9450 10,2 062 10550 9450 — 1002 62 10550 Probe influence Re, Rp max 1,01 Sv ° METREL dé Tel. (+386 1) 7558 200 ~ = METREL Ljubljanska ©. 77 Fax.: (+386 1) 7549 095 SI~ 1354 HORJUL —hiipulwww.metre.s Measurement and Regulation Equipment Manuiaeurers SLOVENIA, e-mail: metrel@metrelsi Metrel Certificate of Calibration Practices The Metrel Quality System is certified by BVQI according to Quality standard ISO 9001:2015, Certificate No. SL22466Q. The Metrel hereby certifies that the above instrument was calibrated in accordance with applicable Metrel calibration procedures during the manufacturing process. These processes are ISO 9001 controlled and are designed to assure that the instrument will meet its published specification. The Metrel further certifies that the measurement standards and instruments used during the calibration of this instrument are traceable to the (inter)national standards. The policies and procedures at this facility comply with EN ISO/IEC 17025. Environmental conditions: © Temperature: 23 °C + 5 °C Relative humidity: 10 % to 75 % Calibration Procedure: “Name of Model / Type” Uncertainty: The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by coverage factor k = 2, which for a nominal distribution corresponds to a coverage probability of approximately 95%. The standard uncertainty of measurement has been determined in accordance with EA Publication EA-4/02. | (Yrol fore Edvard Reven Janko Mole Chief Executive Officer Head of Calibration Laboratory Eurotest XE MI3102 BT — Sereno 20290869 Date: 22. 10. 2020 Performed by: Koprivec, Petkovéek No.: | Function / Ubat= 7,5 V Input | Low limit | Reading | Uncertainty [High limit 18. Earth2 Clamps 10-0802 1,00 0022 1,202 17,109 18,72 059 209009 - a 29,0 102 3600 19. Earth RO-p . 6,30 019m 660m 628 kam 625 0,04kOQm 6,59 km 20. Clamp A1391, range 40 A input AC voltage, f = 50 Hz 390mV 3794 401A 2mV 193A 207A 4mV 036A input DC voltage 330mV 321A 33,4 339A Wmv 727A 7,82 TBA omV 679A 7,04 720A SmV 046A 0,49 001A O44 Omv 000A 0,04 001A 002A Clamp A1391, range 300 A input AC voltage, f = 50 Hz 290mV 2808 290,2 7A 2992 input DC voltage 290mV 2808 290,3 L7A 2992 21. Clamp A1018, range 20 A input AC current, f = 50 Hz I9A 1843 18,93 OIA 1957 = O5mA _00mA 07 O.1mA _L0mA 22, ISFL SFL 2mA —-16mA 4,90 002mA_— 24 mA 78mA — 7.1mA 7,4 OlmA 85a IsFL2 2mA —-6mA 4,90 0,02mA. 2,4 mA - 78mA 71mA 74 O1mA__85mA 23. IMD PASS 7 Ail results in accordance with technical specification. 7 Reference instruments: No, Instrument Type Centiticate No. Due + Calan Sytem 9100, Wavetek moons 31.07.2021 - 3 METREL’ Measurement and Regulation Equipment Manufacturers METREL d.d Ljubljanska c. 77 SI ~ 1354 HORJUL SLOVENIA Tel. (+386 1) 7558 200 Fax.: (+386 1) 7549 095, hitp:/www.metrel.si ‘e-mail: metrel@metrel.si Metrel Certificate of Calibration Practices The Metrel Quality System is certified by BVQI according to Quality standard ISO 9001:2015, Certificate No. SL22466Q. The Metrel hereby certifies that the above instrument was calibrated in accordance with applicable Metrel calibration procedures during the manufacturing process. These processes are ISO 9001 controlled and are designed to assure that the instrument will meet its published specification. The Metrel further certifies that the measurement standards and instruments used during the calibration of this instrument are traceable to the (inter)national standards. The policies and procedures at this facility comply with EN ISO/IEC 17025. Environmental conditions: Temperature: 23 °C + 5 °C Relative humidity: 10 % to 75 % Calibration Procedure: “Name of Model / Type” Uncertainty: The reported expanded uncertainty of measurement is stated as the standard uncertainty of measurement multiplied by coverage factor k = 2, which for a nominal distribution corresponds to a coverage probability of approximately 95%. The standard uncertainty of measurement has been determined in accordance with EA Publication EA-4/02. | phot. fash Edvard Reven Janko Mole Chief Executive Officer Head of Calibration Laboratory

También podría gustarte