Está en la página 1de 1

●LOCATION / LOCALIZACIÓN●

1 1' 3 4 6 7 8 8' 10 13 13' 14 14' 18 19 19' 20' 21 21' 23 23'

41.06
28

8.25 8.43 4.95 4.75 7.42 7.27


41.06 0.50
0.50 8.25 1.93 2.91 1.15 2.09 2.37 2.58 4.05 7.42 1.31 1.35 1.15 2.72
8.25 8.43 5.30 4.40 7.42 7.27 3.10
3.09 0.35 0.35 0.35 0.57 0.16
CT-1
CT-1

●ADDRESS / DIRECCIÓN●

CT-1

CT-1
3.08
Av. de las Naciones No. 24 Nuevo Parque Industrial,
San Juan del Río, Querétaro C.P.76806
1.62 1.31 2.48 2.78 3.08 1.94 2.04 1.87 1.35
A 1.31 7.34
0.35

2.03 ●SYMBOLOGYS / SIMBOLOGÍA●


Z-3.1 Z-2 Z-2.6 Z-2.5 Z-2.5 Z-2 CA-01 CA-01 CA-01 CA-01
EXPANSION DETAIL
PB-1 PB-1 PB-1 PB-1 K-2 PB-1 K-2 PB-1 K-2 AMPLIACIÓN DE DETALLE

CT-1 A TERRAIN POLYGON

CT-1

CT-1
POLÍGONO DE TERRENO
K-2 K-2 K-2 CA-01 CA-01 K-2 K-2
K-2 NPT

1.28
LEVELS ON PLAN DETAIL NUMBER
ZC-1 ZC-1 ZC-1 CA-01 ZC-1 CA-01 ZC-1 ZC-1 0.00

1.53
1.55
NIVELES EN PLANTA
1.07

1 NÚMERO DE DETALLE

A' Z-3.3 PLANO


REFERENCE DRAWING

2.13
CA-01 CA-01 NPT ELEVATIONS AND SECTIONS LEVELS PLANO DE REFERENCIA
PB-1 0.00
k-2 B NIVELES EN ELEVACIÓN Y CORTES
3.00

B' CT-1 CT-1 INDIQUES FINISHES


INDICA ACABADO

CT-1

1.29
CA-01 CT-1 CA-01 K-3 VENTANA
GLASS AND ALUMINIUM TYPE
WEST WALL/MURO PONIENTE
1.33

TIPO DE CANCEL
NORTH WALL/MURO NORTE

0.69

1.75
1.73
CA-01 CA-01 PUERTA DOOR TYPE
CA-01 CT-1 CA-01 CA-01 TIPO DE PUERTA

C' CA-01
CT-1 CT-1 CA-01 C CEILING/CIELOS

CT-1
EAST WALL/MURO ORIENTE

CT-1
CA-01 FLOORING DESIGN

1.29
CT-1

CT-1

CT-1
CA-01 ARRANQUE DE PISO FLOORS/PISOS
ZC-1 ZC-1 1.25 SOUTH WALL/MURO SUR
1.45

0.87
1.70
CHANGE CEILING FINISHES ZOCLOS

CT-1
CA-01 CA-01 CA-01 CAMBIO ACABADO CIELO
INDIQUES ELEVATION
E

14.62
CA-01 CA-01 CA-01CT-1 CA-01 CT-1 CHANGE FLOOR FINISHES INDICA ELEVACIÓN
CAMBIO ACABADO PISO
CT-1 CT-1 CT-1
8.03

E' CA-01
8.03

DETAIL NUMBER
3.00

CHANGE WALL FINISHES


1

0.60
ZC-1 CT-1 NUMERO DE DETALLE

1.82
CAMBIO ACABADO MUROS DRAWING REFERENCE
ZC-1 AA-BB-00

CT-1

CT-1
CA-01 CA-01 PLANO DE REFERENCIA
CHANGE OF LEVEL

CT-1
1.96

CAMBIO DE NIVEL INDIQUES SECTION

1.71
INDICA CORTE
2.00 3.00 3.00 CA-01 CT-1 CA-01 WALL TYPE

1.06
K-2 00_000.00
TIPO DE MURO 1 DETAIL NUMBER
CA-01 K-2 F NUMERO DE DETALLE

0.47
PLANO
CA-01
CA-01 CT-1 CA-01 CA-01 CT-1
CA-01 CA-01 CA-01CT-1 CA-01 CT-1 CA-01 CA-01
CT-1 CA-01
FINISHES TYPE
DRAWING REFERENCE
PLANO DE REFERENCIA
F' 00_000.00
TIPO DE ACABADO

2.06 CT-1 1.15 1.78 1.14 CA-01

2.27
CT-1

CT-1

CT-1
13.53

Z-1.2 Z-1.3
13.53

●GENERAL COMMENTS / NOTAS GENERALES●


14.54

ZC-1
2.22

CA-01 PB-1 1.15 3.00 3.00 PB-1 3.00 2.04 G

0.20
2.73
0.21

CT-1
1. DIMENSIONS RULE OVER DRAWING.
H 0.83 1.27 1.98 1.12 0.45 K-2 K-2 CT-1 CT-1
1.15
CA-01
2. ARCHITECTURAL DRAWING RULES OVER STRUCTURAL AND OTHER ENGINEERING DRAWINGS, ANY DIFFERENCES BETWEEN THESE DOCUMENTS

ZC-1 CT-1 CA-01 CT-1 SHALL BE CONSULTED WITH THE PROJECT MANAGER.
3. BEFORE STARTING ANY CONSTRUCTIONS ALL DIMENSIONS AND LEVELS SHALL BE VERIFIED. IF THERE ARE ANY INCONSISTENCIES, THESE SHALL
K-2 CT-1 CA-01 CA-01 CA-01 CA-01 CA-01 G' BE CONSULTED WITH THE PROJECT MANAGER.

0.22
CA-01 CA-01 CA-01 CA-01
H' Z-1.1 Z-2.4 4. ALL ARCHITECTURAL LEVELS SHALL BE RELATED TO A LEVEL REFERENCE POINT, WHICH SHALL BE SPECIFIED AT THE JOBSITE

CT-1
CA-01

1.99
5. ALL DIMENSIONS, EXCEPT WHERE IT IS INDICATED OTHERWISE, ARE TO FINISHED SURFACE. THEREFORE THEY SHALL BE CONSIDERED DURING

2.15
PB-1 PB-1

1.57
CT-1
CA-01
Z-2.3 Z-1 Z-1.1 EXECUTION OF CONSTRUCTION

1.73

1.73
2.48
PB-1 1.16 PB-1 PB-1 6. THE LAST REVISION DATE INDICATED IN THIS DRAWING REPLACES THE PREVIOUS

0.60
7. THE DIMENSIONS AS THE VOLUMES AS SHOWN IN THE DRAWINGS AND IN THE BIDDING DOCUMENTS ARE ONLY REFERENTIAL, THE
CA-01 CA-01 CA-01
CA-01 CA-01 CT-1 CA-01 CA-01
RESPONSIBILITY IS ENTIRELY OF THE CONSTRUCTOR OF THE TOTAL EXECUTION OF ALL CONSTRUCTIONS ACCORDING TO APPLICABLE RULES,
CA-01
I

0.60
SPECIFICATIONS, STANDARDS AND REGULATIONS

CT-1
CA-01 CT-1 CA-01 CT-1

CT-1
CA-01 8. TEXT IN SPANISH PREVAILS OVER ENGLISH TEXT.

ZC-1 CA-01 1. LAS COTAS RIGEN AL DIBUJO.

CT-1

CT-1

CT-1
5.50

CT-1 ZC-1 CA-01


5.50
5.29

CT-1 CT-1

2.15

2.15

2.15
CT-1 2. LOS PLANOS ARQUITECTÓNICOS RIGEN A LOS PLANOS ESTRUCTURALES Y DEMÁS INGENIERÍAS, CUALQUIER DISCREPANCIA EN ELLOS SE
I'

CT-1

0.70
DEBERÁ CONSULTAR CON LA DIRECCIÓN DEL PROYECTO.

ZC-1
CA-01

1.05
3. SE DEBERÁN VERIFICAR TODAS LAS MEDIDAS Y NIVELES EN OBRA, ANTES DE INICIAR CUALQUIER TRABAJO, SI EXISTIERAN DIFERENCIAS SE

2.48

CT-1
CA-01 CA-01 CA-01 CA-01 DEBERÁ CONSULTAR CON LA DIRECCIÓN DEL PROYECTO.
CT-1 J

0.20
CA-01
4. TODOS LOS NIVELES ARQUITECTÓNICOS SERÁN REFERIDOS A UN BANCO DE NIVEL DETERMINADO EN OBRA.
0.46

CT-1

CT-1
5. SALVO DONDE SE INDIQUE CUALQUIER OTRA CUESTIÓN, TODAS LAS COTAS SON A ACABADOS, POR LO CUAL DEBERÁN SER
CA-01 CA-01
CT-1 CONSIDERADOS EN LA EJECUCIÓN DE LA OBRA.

1.62
CA-01

0.85
CT-1 CA-01
J'

2.02
K' 6. LA ÚLTIMA REVISIÓN FECHADA EN ESTE PLANO SUSTITUYE AL ANTERIOR.

1.99
0.76
CT-1 CT-1 CT-1 Z-3.2 7. LAS DIMENSIONES COMO LOS VOLÚMENES INDICADOS EN LOS PLANOS Y EN LOS DOCUMENTOS DE LA LICITACIÓN SON ÚNICAMENTE DE
CT-1

1.05
Z-3 K-2 CA-01
PB-1 CARÁCTER REFERENCIAL, SIENDO DE ABSOLUTA RESPONSABILIDAD DE LA CONSTRUCTORA LA EJECUCIÓN TOTAL DE LAS OBRAS DE ACUERDO

ZC-1
PB-1 K-2 CA-01
CA-01 ZC-1 CA-01 CA-01 CA-01 CA-01 CA-01 CA-01 A NORMAS, ESPECIFICACIONES, ESTÁNDARES Y REGLAMENTOS APLICABLES.
K
L' Z-2.2 Z-2.2 Z-2.1 Z-2.1 Z-2.7 ZC-1
8. LOS TEXTOS EN ESPAÑOL PREVALECERÁN RESPECTO AL INGLÉS.

K-2 0.49 2.76 1.49


PB-1 PB-1 PB-1 PB-1 PB-1 0.97 0.61 0.70 ●SPECIAL COMMENTS / NOTAS ESPECIALES●
L
0.52

M 16.82 4.30 1.35 4.05 2.00 4.73 3.39 1.41 1.37 1.31
1.
2.
DIMENSIONS RULES OVER DRAWING / LAS COTAS RIGEN SOBRE EL DIBUJO
LEVELS ARE INDICATED IN METERS/ NIVELES INDICADOS EN METROS

REVISAR MEMORIA DE CALCULO, M


3. NPT = FINISHED FLOOR LEVEL/ NPT = NIVEL DE PISO TERMINADO

1 ESPECIALMENTE
8 LOS DATOS 12 13' 14 15 17 20 20'' 21 22 22' 23'
●MASTER PLAN / PLANO GENERAL●

INDICADOS DENTRO DEL CIRCULO.


FOUNDATION FLOOR PLAN NO COINCIDEN
PLANTA DE CIMENTACIÓN LA MEMORIA DE CALCULO DEL 08 DE ABRIL REV003, ESTA
15
CONCRETE CASTLE 12X20 CM
INCOMPLETA, YA NO TRAE EL DISEÑO DE LA CIMENTACION Y POR
ESC. 1:100
CHECK THE CALCULATION TANTO NO SE PUEDE REVISAR LO DE LAS PLACAS BASE Y ANCLAS.
REINFORCED OF 4 VAR #3 WHIT
STIRRUPS # 2 @ 20 CM CONCRETE

DOCUMENT, ESPECIALLY THE DATA


FILLING F'C=200KG/CM2

20
THE CALCULATION REPORT OF APRIL 08 REV003, IS INCOMPLETE,
CASILLO DE CONCRETO ARMADO

INDICATED WITHIN THE CIRCLE. IT DOES NOT HAVE THE FOUNDATION DESIGN AND THEREFORE
HABILITADO CON 4 VARILLAS #3
ESTRIVOS #2 @20 CM

THEY DO NOT MATCH BETWEEN


CONCRETO F'C/200KG/CM2
IT IS NOT POSSIBLE TO CHECK THE BASE PLATES AND ANCHORS.
0.15
BLOCK WALL/
THEM CONCRETE CASTLE K-2
CASTILLO DE CONCRETO K-2
MURO DE BLOCK ACOT. CM PRUEBA FRECUENCIA
●GRAPHIC SCALE / ESCALA GRÁFICA●
0,8
15 0.00 2.00 4.00

0.15
N.P.T. EJE 10X10CM PREFABRICATED
CASTLE JOINED BY SPOT
WELDING CONCRETE 1.00 3.00 5.00 10.00

ESC.: 1:100

15
FILLING F'C=200KG/CM2
0,45 ARMEX 10X10 CM
CONCRETO
0,15

4 RODS Ø3/8"/ 4 RODS Ø1/2"/ F'C/200KG/CM2 ●OWNER/ PROPIETARIO●


4 VARILLAS Ø3/8" 4 VARILLAS Ø1/2" 0,05 0,18 0,18 0,05
0,05

STIRRUPS Ø3/8"@15cm/
0,55

ESTTIRBOS Ø3/8"@15cm CONCRETE CASTLE CA-01


CONCRET ANCHOR / CASTILLO DE CONCRETO CA-01 OPTIBELT
Parque Industrial Nuevo San Juan,
F´C250KG/CM2/ ACOT. CM
0,8

RODS Ø1/2"@15cm/ ROUND / San Juan del Río Querétaro


VARILLAS Ø1/2"@15cm CONCRETO
REDONDO Ø1"
ANCLAS Ø1"
F'C250KG/CM2
BLOCK WALL/
0,15
0,18

C1,C2 MURO DE BLOCK


0.70
0,75

CONCRETE TEMPLATE
0,25

F'C 100KG/CM2/
STIRRUPS Ø1/4"@15cm/
N.P.T.
0,45

PLANTILLA DE CONCRETO ●PROJECT/ PROYECTO●


F'C 100KG/CM2 EJE 12 ESTRIBOS Ø1/4"@15cm
12 "OPTIBELT SAN JUAN DEL RÍO"
0,18

COMPACTED TEPETATE PL 1"


95% PROCTOR
0,075

TEPETATE COMPACTADO PL 100x100x1/2" SQUARE /


95% PROCTOR

0,35
CARTABONES ●DEVELOPED BY/ DESARROLLÓ●
CONTINUOUS FOOTING ZC-1 4 RODS Ø1/2"/
0,05

FABRICACION Y MONTAJE

PL 1/2" 4 VARILLAS Ø1/2"


EJE DE ABASTOS S.A. DE C.V.
DALE DESARROLLOS
DE ESTRUCTURA METALICA

ZAPATA CORRIDA ZC-1 ANCHOR Ø1" /


Calle Oriente 6 # 9, Carretera Federal 45

PB-1
Colonia Parque Industrial, Huichapan km 79.5

ESC. 1:16
3 San Juan del Río,
Querétaro, México
C.P. 76806
Puerta de Palmillas
San Juan del Rio, Qro. C.P. 76837
Oficinas. (427) 266 22 15

ANCLA Ø1" ®
Tel: +52 (427) 138100
contacto@daledesarrollos.com
https://www.facebook.com/FAMEP.SA

CT-1 DESARROLLOS

ESC:1:10 ESC:1:10 45º www.daledesarrollos.com

S/E ●DESIGNED BY/ DISEÑO●


EJE DE ABASTOS/DALE DESARROLLOS
Company/ Empresa:________________________________ FAMEP S.A. DE C.V.
Company/ Empresa:________________________________

Name/ Nombre:___________________________________ ING.VICTOR MANUEL BARCENAS OTERO


Name/ Nombre:________________________________________

Speciality/ Especialidad:_____________________________ STEEL STRUCTURE


Speciality/ Especialidad:_____________________________

BLOCK WALL/ Signature/ Firma:__________________________________ Signature/ Firma:__________________________________


MURO DE BLOCK
●APPROVED BY/ APROBÓ●
ICONICO
Company/ Empresa:________________________________ OPTIBELT
Company/ Empresa:________________________________

0,15 EJE
SYMBOLOGY FOR WELDING/ GERT GRAF
Name/ Nombre:___________________________________ PETER SZEREDAY
Name/ Nombre:___________________________________

0,15 N.P.T. TIPO DE LA


SIMBOLOGIA PARA SOLDADURA.
RELLENO EN VARILLA
Speciality/ Especialidad:_____________________________ Speciality/ Especialidad:_____________________________

SOLDADURA.
FILETE B I S E L (*) CON PLACA. Signature/ Firma:__________________________________ Signature/ Firma:__________________________________

h h ●REVISIONS HISTORY/ HISTORIAL DE REVISIONES●


POSICION DE LA Date /
REV #.
a Fecha Description/Descripción:
SOLDADURA. h
00 02/11/23 For revision/Para revisión
CONTINUOUS FOOTING/ Observations and comments from Supervision are attended/Comentarios
ZAPATA CORRIDA 01 03/06/23
ISOLATED FOOTING/ LADO VISIBLE. h a h y observaciones de la Supervisión son atendidos
ZAPATA AISLADA 02 04/07/23
Requested information is completed /Se complementa información
solicitada.
h a h
LADO NO VISIBLE.

AMBOS LADOS. h h
a
WELDING APPLICATION
APLICACION DE LA SOLDADURA.

APPROVED WITH COMMENTS


SOLDADURA DE TALLER SOLDADURA DE CAMPO ALREDEDOR.
●CODE/ CLAVE●

REV. 02 EA_EST_01
LENGTH OF THE LACES.
LONGITUD DE LOS CORDONES.
19/04/2023 ●CONTENT/ CONTENIDO●

FOUNDATION PLAN
●REVIEW / REVISION No.●

REV.02
TODA LA LONGITUD. PARCIAL. INTERMITENTE. PLANTA DE CIMENTACION

FOUNDATION INTERSECTION/ a

xxxxxxxxxxxxxxxxxxxxxxxxxxxx
h

xxxxxxxxxxxxxxxxxxx
h

xxxxx xxxxx xxxxx xxxx


-s
●SPECIALTY / ESPECIALIDAD●

STRUCTURAL
●SCALE / ESCALA●

INDICATED
●DIMENSION / DIMENSIÓN●

INDICATED

INTERSECCION DE CIMENTACION (*) CUANDO NO APARESCA EN EL SIMBOLO EL VALOR "a" SE TOMARA ESTE COMO CERO.
S ESTRUCTURAL INDICADA INDICADA

●ELECTRONIC FILE / ARCHIVO ELECTRÓNICO● ●DATE / FECHA●

April 07th 2023


2201_OPL_EA_EST_01.dwg 07/Abril/2023