VORATEC SD 211
Polyol

Description
VORATEC* SD 211 polyol is fully VORATEC SD 211 polyol already This formulation gives foam with
formulated polyether polyol to be contains HCFC 141b premixed and good flowability and dimensional
used with VORATEC SD 100 can be processed directly on high stability as well as good adhesion
isocyanate to make rigid poly- and low pressure equipment. and short demould time.
urethane foam for refrigerator and
freezer insulation.

Typical Properties Units Limits Test Methods


Hydroxyl number mg KOH/g 355 ASTM D-4274-94d
HCFC 141b content % 18.7
Viscosity, 20°C mPa.s 550 ASTM D445-94
Specific gravity, 20°C g/ml 1.13
Storage temperature °C 10-20
Storage stability1 months 6
1
Stored in the original sealed drums in a dry place at the recommended temperature.

Recommended formulation parts by weight


VORATEC SD 211 polyol 100
VORATEC SD 100 isocyanate 130

*Trademark of The Dow Chemical Company See "Handling and Storage" last page !

Dow Plastics, a business group of The Dow Chemical Company and its subsidiaries. Form No. 109-51151-0101MJ
CH 381-174-E-0101
Page 1 of 3
Reaction Characteristics1 Units Handmix High pressure
machine
Cream time sec. 11-15 7-9
Gel time sec. 77-90 49-59
Tack free time sec. 125-145 85-110
3
Free rise density kg/m 24-27 21-24
1
Reaction characteristics at 20°C component temperature. Actual values vary depending on processing conditions.

Typical Foam Properties Units Limits Test Methods


Moulded density kg/m3 34 DIN-EN-ISO 845-95
Closed cell content % >95 Internal Norm 2
Initial thermal conductivity at 10°C mW/mK 19 DIN 52612-84
Compressive strength kPa 135 DIN 53421-06-84
perpendicular to rise direction
Dimensional stability % <1 ISO 27961
(ISO 2796 volume change)
20 h at -25°C

Testing methods available on request.

For detailed information on product


handling and emergency procedures,
please consult the Safety Data Sheet.

*Trademark of The Dow Chemical Company Form No. 109-51151-0101MJ


Page 2 of 3 CH 381-174-E-0101
Safety Considerations
Safety Data Sheet [SDS] for Skin and Eyes Fire fighters should wear positive
VORATEC* SD 211 formulated polyol When working with VORATEC SD 211 pressure, self-contained breathing
is available from The Dow Chemical formulated polyol, avoid contact with apparatus.
Company. SDS is provided to help eyes or skin. Safety glasses are Formulated polyols if exposed to
customers satisfy their own handling, suggested for use with most polyols. heat in confined area may generate
safety and disposal needs, and those However, some VORATEC formulated sufficient volatile gases to present an
that may be required by locally polyols require that chemical explosion hazard.
applicable health and safety workers’ goggles be worn. See the Polyols are stable under normal
regulations. SDS sheets are updated Product specific SDS, Section 8. conditions. Materials to avoid are
regularly. Therefore, please request Skin contaminated with polyols oxidising compounds. Hazardous
and review the most current SDS should be washed with soap and polymerisation may occur with
before handling or using any product. plenty of water. If formulated polyol isocyanates.
Copies of the SDS are available on or system contacts eyes, flush with
request through your nearest Dow plenty of low-pressure flowing water. Spills and Disposal
Sales office. If irritation occurs from contact with The preferred way of disposal is to
polyols, get prompt medical incinerate under controlled
Toxicity and First Aid attention. conditions in accordance with all
Most VORATEC formulated polyols, Ingestion local and national environmental laws
depending on their composition, Obtain medical attention immediately. and regulations.
might present some hazards and Inhalation
before working with these products it Avoid any exposure to vapours, Customer Notice
is necessary to understand the mists and aerosols. If any ill effects Dow encourages its customers to
hazards involved. See SDS for should occur, get the affected person review their applications of Dow
specific information. to fresh air and obtain prompt products from the standpoint of
Formulated polyols are commonly medical attention. human health and environmental
used in «urethane» applications that quality. To help ensure that Dow
contain other more hazardous Fire and Explosion products are not used in ways for
materials (e.g. isocyanates, amines Formulated polyols are organic which they were not intended or
and blowing agents). Anyone materials that will burn under the tested, Dow personnel are willing to
working with urethane systems must right conditions of heat and oxygen assist in dealing with ecological and
understand all the hazards involved supply. Depending on polyol product safety considerations. Your
in handling such systems and must composition, combustion can lead to Dow representative can arrange the
establish and follow safe work the build-up toxic pyrolysis products proper contacts.
procedures. Recommendations for together with carbon and nitrogen
handling, storage, and disposal of oxides. Store and handle polyols
additional formulation ingredients away from open flame or high heat
should be obtained from its supplier. sources. Fires can be extinguished
with water fog or other conventional
means.

NOTICE: The information and data contained herein do not constitute sales specifications. The product properties may be changed without notice. No liability, war-
ranty or guarantee of product performance is created by this document. It is the Buyer's responsibility to determine whether Dow products are appropriate for Buyer's
use and to ensure that Buyer's workplace and disposal practices are in compliance with applicable laws and regulations. No freedom from any patents or other indus-
trial or intellectual property rights is granted or to be inferred. (January 2001)

We don't succeed unless you do.


*Trademark of The Dow Chemical Company Form No. 109-51151-0101MJ
Page 3 of 3 CH 381-174-E-0101

También podría gustarte