Está en la página 1de 2
VF 400 Godin Avenue 10f2 LAE Quebec oe QC G1M 2K2 anada CALIBRATION CERTIFICATE Customer: Address: Description: Optical Time Domain Reflectometer (OTDR) Serialno. 1181557 Model no.: 7300-SM2-EA, Calibration UF Block G Furing High-Tech Park, No.7, Xian Avenve, FOS. catration dat: 2018-11-18 ‘As found ia catraton |CTspeciheatone @_|Clspeitntons (iy [Clspeciatons cy [Clspeteatons oy [lopeston “See resus page for datas on As found status (Comments on unit status ‘Action taken IINo adjustment was made ‘Adjustments were made [Repair was performed As loft Within specifications: Outside specications: Calibration conditions Temperature: 23°C +2°C Standard(e) used to establish traceability Description Tnventory number [Calibration date [Calibration validity Standard(s) used for “As left” measurements METAS Length Reference Fiber SM LRF2012.02 [2012-05-28 indefinite Remarks: ‘Optical pons are always Geared before calibration EXFO certfies that the unit has been calibrated using standards traceable to 2 national metrology insbtute (NIST. NPL. NRC. METAS or ether) natural physical constants or using ratio measurements, NIST isthe National Institute of Standards and Technology in the USA, NPLis the National Physical Laboratory n the UK, NRC isthe National Research Council in Canada and METAS is the Swiss Federal Ofice of Metrology All uncertainties are reported with a level of confidence of 95 %. Calibration is based on the ISOVIEC 17025 standard “The certiicate shall not be reproduced. excep! in ful, without the writan approval of EXFO. ices rani ee CERT-00161H 2018-11-15 Date Optical Tine Domain Relectometer(OTDR) Model no.: 730C-SM2-EA 2 of 2 Serial no: 1181557 Calibration date 2018-11-45 Dynamic range test (Single Mode) Procedure: IETA-0066 (pulse: 10 ys, range: 240 km, time: 45 5) Nominal wav mi Test imi oral wave Measured eyrariraros ait arr A ie 7310 208 WS Pass 7550 379 350) Pase 1625 384 354 Pass “Atienuation dead zone test (Single Mode) Provedure: TETA-00966 (pulse: 10 ns, range: 065 km, reflectance #5 0B) Nomin Measured atenvation dead zon Test imi aivavaongh ec ater e cit etn Bs ake 7310 a7 aa? Pass 1550 395 470 Pass 1825 402 477 Pass Event dead zone text (Single Mode] Procedure: IETA-00366 (oulse: 3 ne, range: 0.65 km, releclance’ 45 4B) Renna naan Messed eyo cho one Tei inaiar Tae 1310 0.46 I 0.55 Pass 7550 047 059 Pass 1625 050 064 Pass [ Distance calibration (Single Mode) Procedure: 1ETA-00966 (pulse: 50 ns, range: 35 km tive: 153) (ominal wavelength | Measured length | Reference length | Deviation | Uncertainty | Speciicaton | Conformance ink 7 Nona warero|Weasiee ath Ratrencs ra Denston | Urcrant | Specfeat rane vertcaton Asta 710 | _ 236080 736071 019 [006 os 082 i 1550 2361.70 2361.69 __| 007 | 028 087 074 i 1625 7362.18 76229 | om | 018 087, 0.82, i Linearity test (Single Mode) Procedure: IETA-00366 (wavelength: 1310 nm, pulse: 10 ps, range: 25.3 dB, time: 45 6) Measured non linearity “Test mit (a) (dB) Verification As left one 5.08 Pass, OTDR Self-Test Procedure: |ETA-00366 ‘Status (Pass/Fail) Asleft Pass. * Verification status legend: 1) Within specifications i) Within specifications: All measured results are within specications limits. In conformance with ISO/IEC 17025, full compliance cannot be stated because of measurement uncertainties. Nevertheless, results indicate that the instrument is ikely to perform according to specifications; ii) Outside spectications: Some measured results are outside specification limits. Nevertheless, a8 per ISOMEC 17025, non compliance cannot be Slated because of measurement uncertainties: iv) Outside specifications. Uniess otherwise stated, 100 % of shipped units nave all “As left" results in casei CERT-00151H

También podría gustarte

  • Certificado de Trabajo
    Certificado de Trabajo
    Documento1 página
    Certificado de Trabajo
    Lorenzo Carranza
    Aún no hay calificaciones
  • Anthon Ella
    Anthon Ella
    Documento1 página
    Anthon Ella
    Lorenzo Carranza
    Aún no hay calificaciones
  • OXIGENACION
    OXIGENACION
    Documento1 página
    OXIGENACION
    Lorenzo Carranza
    Aún no hay calificaciones
  • Carta de Renuncia
    Carta de Renuncia
    Documento1 página
    Carta de Renuncia
    Lorenzo Carranza
    Aún no hay calificaciones
  • ANTHONELLA
    ANTHONELLA
    Documento3 páginas
    ANTHONELLA
    Lorenzo Carranza
    Aún no hay calificaciones
  • Etiquetas 1
    Etiquetas 1
    Documento1 página
    Etiquetas 1
    Lorenzo Carranza
    Aún no hay calificaciones
  • Etiquetas 1
    Etiquetas 1
    Documento1 página
    Etiquetas 1
    Lorenzo Carranza
    Aún no hay calificaciones
  • Etiquetado Panduit
    Etiquetado Panduit
    Documento1 página
    Etiquetado Panduit
    Lorenzo Carranza
    Aún no hay calificaciones
  • Certificado de Trabajo
    Certificado de Trabajo
    Documento1 página
    Certificado de Trabajo
    Lorenzo Carranza
    Aún no hay calificaciones
  • ETIQUETAS
    ETIQUETAS
    Documento1 página
    ETIQUETAS
    Lorenzo Carranza
    Aún no hay calificaciones
  • ACCESO ECOMOTION 2x1
    ACCESO ECOMOTION 2x1
    Documento22 páginas
    ACCESO ECOMOTION 2x1
    Lorenzo Carranza
    Aún no hay calificaciones
  • Troncal F. O 96.2 Parte 2
    Troncal F. O 96.2 Parte 2
    Documento63 páginas
    Troncal F. O 96.2 Parte 2
    Lorenzo Carranza
    Aún no hay calificaciones
  • Atención Oportuna
    Atención Oportuna
    Documento2 páginas
    Atención Oportuna
    Lorenzo Carranza
    Aún no hay calificaciones