Está en la página 1de 1

JARDIN

ELECTROBOMBA
PVC SAP Ø 3/4"
TANQUE
CISTERNA

REBOSE

PATIO DE
Ø2"

SERVICIO
RRØ4" TPØ2"
Ø2"

CR = 0,25x0,50 CR = 0,25x0,50
NT = +0,10 NT = +0,10
NF = - 0,30 NF = - 0,30
%
1,00
Ø 1/2" S=
S=
1,00
Ø 1/2" %
LLEGA PVC Ø 3" LLEGA PVC Ø 3"
Ø 1/2"
DESAGUE PLUVIAL DESAGUE PLUVIAL
PVC SAP Ø 3/4" VA AL TANQUE ELEVADO
PV
C
Ø2"

TPØ2"
PVC Ø2" AZOTEA

RRØ4"
S=
1,00
COMEDOR %
LLEGA PVC Ø 3"
COCINA AZOTEA DESAGUE PLUVIAL
Y CORRE A NIVEL DE AZOTEA
ESTAR FAMILIAR DORMITORIO 0%
PVC Ø 6" L=15,50 ml S=1,5 %

S = 1,0 TPØ2"
BAJA PVC Ø 3"
DESAGUE PLUVIAL
LLEGA PVC Ø 3" LLEGA PVC Ø 3" LLEGA PVC Ø 3" BAJA PVC Ø 3"

Ø
2"
DESAGUE A.N. DESAGUE A.N. DESAGUE A.N. DESAGUE A.N.
LLEGA PVC Ø 2"
VENT. SANITARIA
Ø 2" RRØ2" Y TERMINA EN SOMBRERO
PVC Ø 2"
PVC Ø 2"
2"
Ø
C

S.H.
PV
PVC SAP CL 12 Ø 1/2"

PVC SAP Ø 1/2"

05 04 03 02 01 07 04 03 02 01 07 06 05 04 03 02 01
LLEGA PVC Ø 4"
S.H. LLEGA PVC Ø 4"
SUBE PVC Ø 2"
LLEGA PVC Ø 4"
VENT. SANITARIA
DESAGUE A.N. DESAGUE A.N. DESAGUE A.N.
TPØ2" TPØ2"

%
1,00
S=
Ø2"

S=
Ø2"
RRØ4" 08 RRØ4" 08 RRØ4"
PVC Ø 4"

1,00
PVC Ø 4" PVC Ø 2"
SUBE PVC SAP Ø 3/4" SUBE PVC SAP Ø 3/4" SUBE PVC SAP Ø 3/4" LLEGA PVC SAP Ø 3/4"

%
Ø2" PVC Ø 4" Ø2"
LLEGA PVC Ø 3" AGUA FRIA A T.E. LLEGA PVC Ø 3" Ø2" AGUA FRIA A T.E. LLEGA PVC Ø 3" Ø2" AGUA FRIA A T.E. LLEGA PVC Ø 3" AGUA FRIA A T.C.
Ø4"

09 10 11 12 13 14 15 09 10 11 12 13 14 15
DESAGUE PLUVIAL DESAGUE PLUVIAL Ø 1/2" DESAGUE PLUVIAL Ø 1/2" DESAGUE PLUVIAL
Ø 1/2" Ø 1/2"
Ø 1/2" Ø 3/4"
TANQUE
ELEVADO
PVC SAP Ø 1/2" VA AL TANQUE CISTERNA

PVC Ø 3"
BAJA PVC SAP Ø 3/4" BAJA PVC SAP Ø 3/4"
AGUA FRIA DEL T.E. AGUA FRIA DEL T.E.

PVC SAP CL 12 Ø 1/2"


PVC SAP Ø 3/4"

PVC SAP Ø 1/2"


LLEGA PVC SAP CL 12 Ø 1/2" LLEGA PVC SAP CL 12 Ø 1/2" BAJA PVC SAP CL 12 Ø 1/2"
TPØ2"
AGUA CALIENTE AGUA CALIENTE AGUA CALIENTE
SALA
LLEGA PVC SAP Ø 3/4" LLEGA PVC SAP Ø 3/4" DORMITORIO LLEGA PVC SAP Ø 3/4"

S=
LAVADO Y

%
1,00
AGUA FRIA DEL T.E. AGUA FRIA DEL T.E. AGUA FRIA DEL T.E.

1,00
PLANCHADO

S=
%
SUBE PVC Ø 2" SUBE PVC Ø 2" SUBE PVC Ø 2" PVC SAP Ø 3/4"
VENT. SANITARIA VENT. SANITARIA PVC SAP Ø 1/2" VENT. SANITARIA
Ø 1/2"
Ø 1/2"
THERMA
S.H. TPØ2" SUBE PVC Ø 2" LLEGA Y PASA PVC Ø 2"
VENT. SANITARIA VENT. SANITARIA
Ø2"

LLEGA PVC SAP CL 12 Ø 1/2" RRØ4" RRØ4" LLEGA PVC SAP CL 12 Ø 1/2" LLEGA PVC SAP CL 12 Ø 1/2" PVC Ø 2"
Ø2" Ø4" PVC Ø4"
AGUA CALIENTE AGUA CALIENTE Ø2" AGUA CALIENTE
4"

Ø2"

RRØ4"
Ø
Ø2"

C
PV
Ø4"

LLEGA PVC Ø 2"


RRØ4" TPØ2" VENT. SANITARIA
Ø 1/2" PVC SAP CL 12 Ø 1/2"
Y TERMINA EN SOMBRERO
S

Ø 1/2"
S.H.
= 1,

AZOTEA
00
%

LLEGA PVC Ø 4"


DESAGUE A.N.
BAJA PVC Ø 2" DESAGUE PLUVIAL
0%
1,0 Y CORRE A NIVEL DE JARDIN
S=
LLEGA PVC Ø 3" LLEGA PVC Ø 3" LLEGA PVC Ø 3"
DESAGUE PLUVIAL DESAGUE PLUVIAL DESAGUE PLUVIAL

PVC Ø 2" S = 1,00 %


PVC Ø 3"
AZOTEA
ESTUDIO
S

%
= 1,

00
= 1,
00

S
%

DORMITORIO

ELECTROBOMBA

TANQUE
CISTERNA
PVC Ø 6" L=15,50 ml S=1,5 %

PVC Ø 6" L=15,50 ml S=1,5 %

REBOSE

CR = 0,25x0,50
NT = +/- 0,00
NF = - 0,55
LLEGA DE LA RED GENERAL

CR = 0,25x0,50
RA

RA

NT = +/- 0,00
CTO

CTO

NF = - 0,70
LE

LE
CO

CO
D

D
RE

RE
LA

LA
A

A
VA

VA