Quick Installation and Startup for Optivity NMS 10.

3 for HP-UX
This card provides brief instructions for installing and getting started with Optivity NMS 10.3 for HP-UX platforms. It is assumed that you are familiar with installing applications on a HP-UX management station. See Installing and Administering Optivity NMS 10.3 for more detailed information. Nortel Networks recommends that you thoroughly read Release Notes for Optivity NMS 10.3 before proceeding to the installation.

System requirements
For best performance, make sure that your HP-UX system meets the following criteria:
HP-UX (PA-RISC) C-series, 552 Mhz processor 2 Gb RAM 20 Gb hard drive

If you are upgrading from Optivity NMS 10.2 to Optivity NMS 10.3
If you are upgrading from Optivity NMS 10.2 to Optivity NMS 10.3, you can use the brief instructions in this guide if you do not want to save your customizations or topology database. If you do want to save your database or customizations, see Installing and Administering Optivity NMS 10.3 for detailed upgrade procedures.

(Upgrading only) Uninstall Optivity NMS 10.2


Use the following commands to remove the Optivity NMS 10.2 software: 1 Log in to your HP-UX station as root. 2 In a terminal window, change to the Optivity NMS install directory:

cd $LNMSHOME/install
3 4 To start the Optivity NMS 10.2 uninstallation program, enter:

uninstall
Use the uninstallation program to remove all Optivity NMS 10.2 components.

Verify and configure kernel parameters


For a new installation, configure kernel parameters as described in Chapter 4 of Installing and Administering Optivity NMS 10.3. If you are upgrading from Optivity NMS 10.2 to Optivity NMS 10.3, you do not need to change your kernel parameters.

(Server only) Run the Optivity NMS 10.3 database installation program
If you are installing an Optivity NMS 10.3 server, you must install the Oracle 9i database software as described below before installing the Optivity NMS 10.3 software. If you are installing just the Optivity NMS 10.3 client software, you dont have to install the Oracle 9i database software. Skip ahead to the section Run the Optivity NMS 10.3 installation program on page 2. 1 Log in to your HP-UX station as root. 2 Insert the Optivity NMS 10.3 Database Installer (1 of 5) CD into your systems CD-ROM drive. 3 Use pfsmount to mount the cdrom. See the section Mounting a local CD drive in the HP-UX environment on page 4 for more information about using pfsmount. 4 Execute the following commands to start the Optivity NMS 10.3 database installer program:

6 7

cd / /cdrom/install Note: Execute the command from the root directory. Do not use cd to change to any deeper directory on the CD. Doing so would interfere with your ability to eject the CD when required. Respond to the installation program prompts for information about your installation, and to insert the additional installation CDs. At the end of this sequence of prompts, the program prompts you: Insert Oracle CD # 4 to continue with Oracle install Insert the CD labeled Optivity NMS 10.3 Database Installer (4 of 5). Execute the following commands: cd /cdrom ./preinstall -i 1

8 9

Respond to the installation program prompts for information about the Oracle installation. Execute the following command:

./install The installation program installs the Oracle database software on the system. At the end of the Oracle database software installation, the installation program prompts you: Insert CD # 5 to proceed with Oracle 9.2.0.4 patch install 10 Insert the CD labeled Optivity NMS 10.3 Database Installer (5 of 5) 11 Execute the following commands: cd /cdrom ./install_patch The installation program installs the Oracle 9.2.0.4 patch.

Run the Optivity NMS 10.3 installation program


If you are migrating from Optivity NMS 10.2 to Optivity NMS 10.3, carefully read and follow the instructions in Installing and Administering Optivity NMS 10.3, Chapter 4 before you install Optivity NMS 10.3. 1 Log in to your Optivity NMS 10.3 HP-UX station (server) as root. 2 Insert the Optivity NMS 10.3 for HP-UX CLIENT and SERVER CD into your systems CD-ROM drive. 3 Use pfsmount to mount the cdrom. See Mounting a local CD drive in the HP-UX environment on page 4 for more information. 4 Execute the following commands:

5 6

cd /cdrom/install ./install Use the installation program to specify parameters for your installation. Accept the default selections unless you want to customize your installation. In the installation program, click Install and then Done to complete and exit the Optivity NMS 10.3 installation.

Set your user runtime environment


Using vi or another text editor, add the following lines to each Optivity NMS user's login script: For the C shell, add the following lines to the .cshrc file:

umask 022 if ( -f /opt/lnms/bin/opt_cshrc ) then source /opt/lnms/bin/opt_cshrc endif For the Korn shell, add the following lines to the .kshrc file: umask 022 if [ -f /opt/lnms/bin/opt_kshrc ];then . /opt/lnms/bin/opt_kshrc fi For the Bourne shell, add the following lines to the .profile file: umask 022 if [ -f /opt/lnms/bin/opt_kshrc ];then . /opt/lnms/bin/opt_kshrc fi To update your environment, close all of your terminal windows, then open new terminal windows. (When you open new terminal windows, your .cshrc, .kshrc, or .profile file is automatically sourced and your environment is updated.)

(Server only) Ensure that all Optivity NMS daemons are running
For an Optivity NMS Server/Client installation, open a terminal window and use the optstatus -fe command to make sure that all of the required services are running:

optstatus -fe Refer to Installing and Administering Optivity NMS 10.3, Chapter 6 and Appendix C for further instructions about services. 2

(Server only) Enter your Optivity NMS software license key


To enter the license key, you use the command optivity_apps stop to stop all ONMS daemons, and then edit the following text file so that it contains the key number printed on your green license key document: /usr/lnms/registration/weboptsrvr/license.dat After editing that text file, restart the daemons using the command optivity_apps start. Refer to Installing and Administering Optivity NMS 10.3, Chapter 3, for more detailed instructions on installing the license key.

Begin using Optivity NMS


After completing the applicable installation procedures, you have installed the Optivity NMS server or client software. Now you are ready to start using InfoCenter. The following sections describe how to get started using InfoCenter and other Optivity NMS applications to discover, view, and manage your network.

Start InfoCenter
InfoCenter is the command center for Optivity NMS. To start InfoCenter: 1 Open a terminal window and at the command line, enter infocenter 2 In the Connect to Optivity NMS Server dialog box, type a valid user name, password, and the server host name or IP address to which you want to connect. The Optivity NMS InfoCenter window opens.

Start Community Strings Editor and add community strings entries


You use the Optivity NMS Community Strings Editor to manage SNMP community strings, SNMPv3 information, Telnet, and SSL settings when Optivity NMS is installed platformless. However, when integrated with a network management platform such as Tivoli Netview, Optivity NMS uses the community strings of the platform software, and the Telnet, SSL, and SNMPv3 settings entered in the Optivity NMS Community Strings Editor. 1 From the InfoCenter menu bar, choose Admin > Community Strings. The Community Strings Editor window opens. 2 Use the Community Strings Editor to create community strings entries as appropriate for your network devices. Some typical requirements are:

For IP telephony devices and components, create community string and Telnet entries For MCS 5100 devices, create community string, SSL, and Telnet entries For BayRS routers, create community string and Telnet entries (to use protocol visualization features) For SNMPv3 devices, create Optivity user entries and enter authentication information and optionally private protocol information.

Start AutoTopology Manager and discover your network resources


1 2 3 4 5 6 From the InfoCenter menu bar, choose Admin > AutoTopology Manager. The AutoTopology Manager window opens. From the AutoTopology Manager menu bar, choose Discovery > Enter Seed Specification. The Seed Information dialog box opens. Create a discovery seed. Type the following: Discovery seed name; IP address of the router from which to start the topology discovery process; IP address range. Click Apply. Click Close. Set discovery options: From the AutoTopology Manager menu bar, choose Setting > Options. Select Network layer options for device discovery, and Protocol Discovery options for specific features. Start Discovery: From the AutoTopology Manager menu bar, choose Discovery > Start Discovery. In the InfoCenter Contents pane, open your resource folders to view your discovered network resources.

Where to go from here


For more information about how to install and get started with Optivity NMS 10.3, refer to Installing and Administering Optivity NMS 10.3. For more information about using the Optivity NMS 10.3 applications, view the online Help. From the menu bar of an Optivity NMS application, choose Help > Help On <application_name>. Also, refer to Using Optivity NMS 10.3 Applications (located on the Optivity NMS 10.3 for Windows* CLIENT ONLY and Documentation CD).

Mounting a local CD drive in the HP-UX environment


To mount a local CD drive in the HP-UX 11.11 environment: 1 Insert the CD in the CD drive. 2 Open a shell window. 3 Use the following command to create the pfs file system table:

touch /etc/pfs_fstab
4 5 6 7 8 9 Use the following command to start the pfsd_mountd and pfsd_mountd.rpc daemons:

/usr/sbin/pfs_mountd &
Use the following command to start the pfsd and pfsd.rpc daemons:

/usr/sbin/pfsd &
If a mount point directory does not already exist, create one by entering:

mkdir <mount_point>
for example:

mkdir /cdrom
Use the following command to find the block device for your CD drive:

$ ioscan -funC disk The system responds with a table of available disk drives as shown below.
# ioscan -funC disk Class I H/W Path Driver S/W State H/W Type Description ======================================================================= disk 0 10/0/14/0.0.0 sdisk CLAIMED DEVICE TEAC CD-532E-B /dev/dsk/c0t0d0 /dev/rdsk/c0t0d0 disk 1 10/0/15/1.6.0 sdisk CLAIMED DEVICE SEAGATE ST336704LC /dev/dsk/c3t6d0 /dev/rdsk/c3t6d0

In the row for the CD drive, note the block device. In the example above, the CD block device name is: /dev/dsk/c0t0d0. 10 Enter the following command to mount the CD:

/usr/sbin/pfs_mount <block_device> <mount_point> Where <mount_point> is the mount point directory and <block_device> is the block device for the CD drive. For example: /usr/sbin/pfs_mount /dev/dsk/c0t0d0 /cdrom To unmount the CD drive, enter: /usr/sbin/pfs_umount <mount_point> For example: /usr/sbin/pfs_umount /cdrom

*217234-A*
Copyright November 2004 Nortel Networks. All rights reserved. Printed in the USA. The information in this document is subject to change without notice. The statements, configurations, technical data, and recommendations in this document are believed to be accurate and reliable, but are presented without express or implied warranty. Users must take full responsibility for their applications of any products specified in this document. The information in this document is proprietary to Nortel Networks, Inc.