Está en la página 1de 2

Well Control Kill Sheet (Low Angle Wells)

Randy Smith Drilling Schools Lafayette, LA Phone: 318-235-4493 Fax: 318-235-4494 (800) 492-9355
Use Metric Units

Drillstring Volume (BBLS)


LENGTH (FT) Drillpipe CAPACITY (BBLS/FT) VOLUME (BBLS)

Annular Volume (BBLS)


LENGTH (FT) CAPACITY (BBLS/FT) VOLUME (BBLS)

Drillpipe & Casing

= = =

0 0 0


Tot. Ann. Len. 0

= =

0 0

Drillpipe (or Collars) & Open Hole

KEY:

Collars

= Enter data here

Wait & Weight Procedure


1. Raise mud weight in suction pit to Kill Weight Mud Value. Monitor Shut-In Pressures for possible Gas Migration. Maintain drillpipe pressure constant at original Shut-In Value if necessary.


Tot. String Len. 0

= 0 = 0
Tot. String Vol. 0

= 0 = 0 = 0 = 0
Tot. Ann. Vol. 0

Well Information and Kick Data Original Mud Weight Total Vertical Depth Total Measured Depth Slow Pump Pressure Slow Pump Speed Pump Output Shut-In Drillpipe Pressure Shut-In Casing Pressure Pit Gain Strokes to Bit Bottom Up Strokes Total Circulation for Well Kill (ppg) (ft) (ft) (psi) (spm) (bbls/stk) (psi) (psi) (bbls)
0 0 0

2.

DP Pressure Schedule Circulating Strokes Pressure (psi)


0 0 0 0 0 0 0 0 0 0 Strokes to Bit 0 0 Initial 0 0 0 0 0 0 0 0 0 0 Final

3.

When KWM is ready, bring pump on line according to Pump Start Up Procedure.

4.

Maintain constant pump speed during kill and adjust choke as needed to control drillpipe pressure as shown on Schedule.

5.

Follow Drillpipe Pressure Circulating Schedule until Kill Weight Mud returns to surface.

Kill Weight Mud

(ppg)

Copyright 1988 Randy Smith Drilling Schools. All Rights Reserved.

Horizontal/Extended Reach Well Control Kill Sheet


Randy Smith Drilling Schools Lafayette, LA Phone: 318-235-4493 Fax: 318-235-4494 (800) 492-9355
Use Metric Units

Drillstring Volume (BBLS)


LENGTH (FT) Drillpipe CAPACITY (BBLS/FT) VOLUME (BBLS)

Annular Volume (BBLS)


LENGTH (FT) CAPACITY (BBLS/FT) VOLUME (BBLS)

Drillpipe & Casing

= = =

0 0 0


Tot. Ann. Len. 0

= =

0 0

Drillpipe (or Collars) & Open Hole

KEY:

Collars

= Enter data here

Kick Off Point & End Of Build Information


KICK OFF POINT (KOP) Measured Vertical (ft) (ft)


Tot. String Len. 0

= 0 = 0
Tot. String Vol. 0

= 0 = 0 = 0 = 0
Tot. Ann. Vol. 0

Well Information and Kick Data Original Mud Weight Total Vertical Depth Total Measured Depth Slow Pump Pressure Slow Pump Speed Pump Output Shut-In Drillpipe Pressure Shut-In Casing Pressure Pit Gain Stokes to KOP Strokes to EOB Strokes to Bit Bottom Up Strokes Total Circulation for Well Kill (ppg) (ft) (ft) (psi) (spm) (bbls/stk) (psi) (psi) (bbls)
0 0 0 0 0

DP Pressure Schedule Circulating Strokes Pressure (psi)


0 0 0 0 Stokes to KOP 0 0 0 0 Strokes to EOB 0 0 0 0 Strokes to Bit 0 0 Initial 0 0 0 0 At KOP 0 0 0 0 At EOB 0 0 0 0 Final 0

END OF BUILD (EOB) Measured Vertical LENGTH (FT) 0 0 (ft) (ft) VOLUME (BBLS)

CAPACITY (BBLS/FT)

Kick Off Point String Volume

= =

0 0

End Of Build String Volume

Kill Weight Mud

(ppg)

Copyright 1988 Randy Smith Drilling Schools. All Rights Reserved.